• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 173
  • 2
  • 1
  • Tagged with
  • 176
  • 176
  • 145
  • 143
  • 37
  • 29
  • 22
  • 21
  • 21
  • 20
  • 20
  • 19
  • 19
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida / Effect of light sources with different wavelengths in micro and ultramicrohardness and elastic modulus of a nanohybrid composite resin. An in vitro study

Jesuina Lamartine Nogueira Araujo 04 June 2013 (has links)
Este trabalho avaliou in vitro a dureza e módulo de elasticidade de uma resina composta nanohíbrida (Tetric N-Ceram/Ivoclair-Vivadent) com diferentes cores, fotoativada por duas unidades com diferentes comprimentos de onda em 3 espessuras (1, 2 e 3mm) comparadas à partir da superfície irradiada (0mm). Os espécimes foram divididos em grupos (n=5): microdureza Knoop-KHN, ultramicrodureza-DUH e módulo de elasticidade-ME, cor (A2 e Bleach-M(BM), fotoativador LEDazul (Elipar Freeligth2/3M(750mW/25s/430-480nm(FL) e LEDazul/violeta Bluephase/Ivoclar/Vivadent (1200mW/cm²/15s/380-515nm(B15) e 30s(B30). Os espécimes foram armazenados por 24h/37ºC. Os ensaios de KHN foram realizados no HMV-2000/Shimadzu, com carga de 25gf/40s, e de DUH e ME no DUH 211S/Shimadzu com força de 10mN e tempo de espera de 0s. Foram realizadas 5 endentações na superfície irradiada (0mm) e na base das amostras (1, 2 e 3mm). A análise estatística foi realizada por ANOVA, Tukey e correlação de Pearson (p<0,01%). O teste de Pearson mostrou haver correlação direta entre a KHN e a DUH. A fonte FL promoveu maiores valores de KHN e de DUH para as duas resinas testadas; enquanto que a fonte B15, promoveu o maior valor de ME. Quanto às espessuras, 0 e 1mm apresentaram maiores valores de KHN e de DUH, e menores de ME que as espessuras de 2 e 3mm. A cor A2 apresentou maior valor de KHN e DUH e menor ME que a cor Bleach-M. Assim, de acordo com a metodologia proposta e os resultados apresentados pode-se concluir que apesar de a luz LEDazul/violeta propor uma maior eficácia na polimerização de resinas de cor clara, no tocante às propriedades avaliadas isso não foi verificado. / This study evaluated in vitro the hardness (micro and ultramicro) and elastic modulus of a nanohybrid composite resin (Tetric N-Ceram/Ivoclar-Vivadent) with different colors, light sources and thickness. The specimens were divided into groups (n=5): KHN-Knoop microhardness, DUH-nanohardness and ME-elastic modulus; colors: A2 and Bleach-M (BM); light sources: LEDblue Elipar Free light 2/3M-ESPE (750mW/cm²/ 25s/430-480nm- (FL)), LEDblue/violet Bluephase/Ivoclar-Vivadent (1.200mw/cm²/15s/380-515nm) (B15) and 30s (B30); thickness: 1mm, 2mm and 3mm, compared to the irradiated surface (0mm). Specimens were stored dry for 24hours at 37ºC after photo curing. Assays were performed at KHN in HMV-2000/ Shimadzu with load of 25gf at 40s and DUH/ME in DUH 211S/Shimadzu with force of 10mN and no hold time (0s). 5 indentations of each test were made in the surfaces opposites to the photo curing. A statistical analysis was performed by ANOVA, Tukey and Pearson correlation (p<0.01%). Pearsons Test showed a direct correlation between KHN and DUH. Comparison between KHN and ME in the studied resins indicated that the light source FL promoted higher values of KHN and DUH to both resins tested, whereas the B15 light source promoted the higher ME value. Regarding thickness 0mm and 1mm showed higher KHN and DUH and lower ME than 2 and 3mm thickness. A2 color showed higher KHN and DUH and lower ME than BM. Thus, according to the proposed methods and the presented results, the LEDblue/violet was not better for curing the light color of the nanohybrid resin, than LEDblue.
82

Influência de diferentes substâncias líquidas sobre a estabilidade de cor de resinas compostas e a efetividade do polimento na recuperação da cor original

Resende, Luís Felipe Marques de 26 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-02-12T14:32:02Z No. of bitstreams: 1 luisfelipemarquesderesende.pdf: 659358 bytes, checksum: e233497985b7b59bfcd9389824074d23 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-02-26T12:17:06Z (GMT) No. of bitstreams: 1 luisfelipemarquesderesende.pdf: 659358 bytes, checksum: e233497985b7b59bfcd9389824074d23 (MD5) / Made available in DSpace on 2016-02-26T12:17:06Z (GMT). No. of bitstreams: 1 luisfelipemarquesderesende.pdf: 659358 bytes, checksum: e233497985b7b59bfcd9389824074d23 (MD5) Previous issue date: 2014-08-26 / O objetivo deste estudo experimental foi avaliar a influência de diferentes bebidas (água destilada, café, chá, vinho tinto e whisky) na estabilidade de cor de quatro diferentes resinas compostas e a efetividade do polimento final para recuperação da coloração inicial. As resinas utilizadas foram Filtek Z250 (microhíbrida), Filtek Z350 (nanoparticulada), IPS Empress Direct (nanohíbrida) e Tetric N-Ceram (nanohíbrida). Foram confeccionados 200 corpos de prova (8 mm x 2 mm), sendo 50 para cada tipo de resina e polidos com disco Sof-Lex em motor elétrico. Um aparelho espectrofotômetro digital foi utilizado para verificação da coloração inicial, após essa avaliação as amostras foram separadas de acordo com a resina composta utilizada em grupos (n=10) e permaneceram imersas nas respectivas soluções durante 14 dias. Após esse período os corpos de prova foram lavados e secos para nova avaliação da cor. Posteriormente os corpos de prova eram polidos e lavados para nova medição no espectrofotômetro. O sistema de parâmetro da coloração utilizado foi o CIEL*a*b*. As alterações de coloração foram verificadas a partir de ΔE1 após 2 semanas e ΔE2 seguinte ao repolimento. Valores acima de 3,3 foram considerados inaceitáveis clinicamente. As diferenças de cor foram estatisticamente comparadas pelo ANOVA two-way e test de Tukey (p<0,05). Com os resultados foi possível observar que o vinho tinto apresentou a maior variação de ΔE seguido pelo café, chá, whisky e água destilada. A resina microhíbrida Filtek Z250 apresentou a melhor estabilidade de cor em todas as substâncias líquidas. O repolimento final não foi efetivo para que as resinas compostas retornassem a sua coloração inicial e nenhuma das resinas apresentou estabilidade de cor clinicamente aceitável em qualquer das bebidas empregas neste estudo. / The aim of this study was to evaluate the influence of different beverages (distilled water, coffee, tea, red wine and whisky) on color stability of four different composites and the effectiveness of the polish to recover the initial color. The resins used were Filtek Z250 (microhybrid), Filtek Z350 (nanoparticles), IPS Empress Direct (nanohybrid) and Tetric N-Ceram (nanohybrid). A total of 200 specimens (8 mm x 2 mm), 50 for each type of resin were prepared and polished with Sof-Lex disc and electric motor. A digital spectrophotometer device was used to verify the initial color, after this evaluation samples were separated in accordance with the composite resin in groups (n = 10) and remained immersed in the respective solutions for 14 days. After this period the specimens were washed and dried for other evaluation of color. Subsequently, the composites were polished and washed to new measurement in the spectrophotometer. The system parameter staining was used CIEL * a * b *. The color changes were observed from ΔE1 after two weeks and following the repolishing ΔE2, values ΔE≥3.3 are considered clinically unacceptable. Color differences were statistically compared using ANOVA two-way and Tukey test (p <0.05). With the results was observed that red wine had the highest variation of ΔE followed by coffee, tea, whisky and distilled water. The microhybrid Filtek Z250 showed better color stability in all beverages. The repolishing was not sufficient to composite resins return to its original color and neither resin was color stability clinically acceptable in any of the drinks incorporate in this study.
83

Avaliação comparativa da resistência à abrasão de resinas compostas "condensáveis", submetidas à escovação simulada, através da alteração de massa e da rugosidade superficial. / "In vitro" ëvaluation of abrasion resistance of "condensable" composite resins after toothbrushing. Wear and superficial roughness analysis.

Linda Wang 02 March 2001 (has links)
Resinas compostas "condensáveis" correspondem a uma nova categoria de material restaurador posterior especialmente desenvolvida como alternativa estética ao amálgama. O objetivo deste trabalho foi comparar algumas marcas comerciais Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) e Filtek P-60 (P-60) a dois grupos controles, Silux Plus (SP), de micropartículas, e Z100 (Z), microhíbrida, por meio de um teste in vitro de escovação simulada. Doze corpos-de-prova de cada material foram confeccionados com dimensões de 5mm de diâmetro por 3mm de espessura. Foram realizados 100.000 ciclos de escovação em uma máquina de escovação simulada, utilizando escovas dentais de cerdas macias e solução de dentifrício e água deionizada. A alteração de massa foi verificada pela diferença entre as médias de massa inicial (antes da escovação) e final (depois da escovação) em balança analítica Sartorius. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 e por meio de microscopia eletrônica de varredura. Os resultados obtidos foram submetidos à análise de ANOVA e Tukey, apresentando diferenças significantes para perda de massa e alteração de rugosidade. As resinas SureFil e Alert apresentaram menor alteração de massa (0,38% e 0,52%), enquanto Solitaire, Prodigy Condensable e Silux Plus as maiores (1,51%, 1,55%, 1,70%). Z100 e P-60 apresentaram alteração de massa intermediária às outras resinas. Diferentemente dos outros grupos, Prodigy Condensable, Solitaire e Z100 apresentaram, após a escovação, superfícies mais lisas (-0,012mm, -0,047mm e -0,065mm respectivamente), enquanto a rugosidade superficial aumentou nos demais grupos (A= 0,073mm, P-60= 0,095mm, Si= 0,158mm e Su= 0,470mm). SureFil apresentou a menor perda de massa e a maior variação de rugosidade superficial comparada às demais resinas testadas. Não houve correlação entre perda de massa e rugosidade superficial. As análises realizadas em microscopia eletrônica de varredura apresentaram-se coerentes com os resultados quantitativos obtidos. De maneira geral, as resinas compostas "condensáveis" apresentaram comportamento semelhante entre si e em relação à resina microhíbrida Z100. / "Condensable" composites resins are a category of posterior materials especially developed as an aesthetic alternative to amalgam. The aim of this research was to compare these materials by an "in vitro" abrasion test simulating toothbrushing. Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) and Filtek P-60 (P-60) were compared to two control groups, microfilleD Silux Plus (SP) and microhybrid Z100 (Z). Twelve samples of each material were prepared with 5mm in diameter and 3mm thick. The abrasion test was applied up to 100.000 cicles by an appropriate machine with soft bristles tips containing dentifrice solution and deionized water. The weight loss was detected by the differences between the initial (before toothbrushing) and the final weight (after toothbrushing) using a Sartorius analytical scale. The evaluation of surface roughness was observed by the difference between initial and final means after 5 readings in a Hommel Tester T1000 testing machine. The specimens were also analysed by SEM. The obtained results (ANOVA and Tukey) showed significant differences of weight and surface roughness between the tested materials. SureFil and Alert exhibited lower loss of weight (Su-0.38%; A-0.52%), Solitaire, Prodigy Condensable, and Silux Plus presented greatest wear(So-1.51%; PC-1.55%, SP-1.70%) while Z100 and Filtek P-60 showed intermediate loss ( Z-1.16%; P-60-1.31%). Differently to the others groups, Prodigy Condensable, Solitaire and Z-100 showed a decrease in surface roughness compared to the initial condition (-0.012mm,-0.047mm and -0.065mm respectively) which increased in the remainder groups (A) 0.073mm, P-60) 0.095mm, Si) 0.158mm and Su) 0.470mm). SureFil presented the lowest weight loss and the highest surface roughness variation comparing to the other tested resins. There was no correlation between wear and surface roughness. The SEM results were in accordance to those obtained by the Hommel Tester T1000 testing machine. "condensable" composites resins showed the same behavior compared to the microhybrid Z100 control resin.
84

Resistência adesiva dos cimentos resinosos convencionais e autoadesivos à dentina contaminada por saliva / Bond strength of different composite resin cements and dentin interfaces contaminated with saliva

Victor Manuel Acosta Servián 20 April 2012 (has links)
Muitas das lesões dentárias necessitam de restaurações indiretas que requerem cimentos adesivos para a sua fixação à estrutura dentária. Em algumas situações não é possível realizar o isolamento absoluto do campo operatório, o que pode levar à contaminação com saliva da dentina previamente aos procedimentos adesivos. Assim é necessário saber o nível de comprometimento da adesão em função deste fato. O presente estudo teve como objetivo analisar o tratamento da dentina contaminada com saliva na resistência adesiva dos cimentos resinosos convencional e autoadesivo através de testes de cisalhamento. Foram utilizados 50 incisivos bovinos que foram lixados até a exposição de dentina superficial e divididos em 6 grupos: Grupo ARC (controle): condicionamento ácido por 15s + sistema adesivo Scotchbond Multipurpose (3M/ESPE) + cimento RelyX ARC (3M/ESPE); Grupo ARClav: condicionamento ácido por 15s + contaminação com saliva + lavagem com água/ar 20 segundos + sistema adesivo + cimento RelyX ARC; Grupo ARCsec: condicionamento ácido por 15s + contaminação com saliva + secagem com papel absorvente + cimento autoadesivo RelyX ARC; Grupo ARCre: condicionamento ácido por 15s, contaminação + secagem jato de ar + recondicionamento por 15s + sistema adesivo Scotchbond Multipurpose + cimento RelyX ARC; Grupo U100 (controle): sem contaminação + cimento autoadesivo RelyX U100 (3M/ESPE); Grupo U100sec: contaminação + secagem jato de ar + cimento autoadesivo RelyX U100. Após a cimentação, os dentes foram armazenados em água destilada a 37ºC por 24 horas antes da realização do teste de cisalhamento. Os resultados obtidos foram submetidos à análise de variância a dois critérios e teste de Tukey com nível de significância de 5%. As médias gerais, dos grupos,expressas em MPa, foram G ARC: 9,02 ± 1,36 - G U100: 4,38 ± 0,74 - GARClav: 6,43 ± 0,98 GARCsec: 7,71 ± 1,14 GARCre: 5,68 ± 1,10 G U100sec: 3,87 ± 0,51. A análise dos resultados permitiu concluir que a adesão do cimento RelyX à dentina contaminada com saliva, lavada ou recondicionada com ácido fosfórico diminui significantemente quando comparada à adesão à dentina não contaminada ou àquela contaminada e apenas seca com papel absorvente. Já a contaminação com saliva não afetou significantemente a adesão do cimento RelyX U100 à dentina. / Many dental injuries require indirect restorations fixed by adhesive cements. In some situations is not possible to isolate the operative field, which can lead to contamination by saliva of the dentin. The aim of this study was to analyze the treatment of dentin contaminated with saliva on shear bond strength of conventional and self-adhesive resin cements. Fifty bovine incisors were ground until exposure of dentin surface and divided into six groups: Group ARC (control) no contamination + acid etch for 15s + Scotchbond Multipurpose system (3M/ESPE) + cement Rely X ARC (3M/ESPE); Group U100 (control): no contamination + self-adhesive cement RelyX U100 (3M/ESPE), Group ARClav: acid etch for 15s + saliva contamination + rising with water / air + adhesive system RelyX ARC, Group ARCsec: acid etch + contamination with saliva + drying with absorbent paper cement RelyX ARC, Group ARCre: acid etched, contamination with saliva + drying with absorbent paper + reetched for 15s + adhesive system Scotchbond Multipurpose + cement RelyX ARC, Group U100sec: contamination + drying with absorbent paper + self-adhesive cement RelyX U100. After cementation, the teeth were stored in distilled water at 37° C for 24 hours prior to shear testing. The results were analyzed by One-way ANOVA and Tukey\'sTests with a significance level of 5% were: G ARC: 9.02 ± 1.36 G U100: 4.38 ± 0.74 G ARClav: 6.43 ± 0.98 G ARCsec: 7.71 ± 1.14 G ARCre: 5, 68 ± 1.10 G U100sec: 3.87 ± 0.51.The results showed that there was a significant difference in bond strength of RelyX ARC to dentin contaminated by saliva when it was rinsed or re-etched, but there was no difference when the contaminated dentin was just dried with absorbent paper. No statistical difference was found between the adhesion resistance of the RelyX U100 to dentin with or without saliva contamination.
85

Avaliação do desgaste por escovação, in vitro, de uma resina composta, fotopolimerizada por lâmpada halógena, em dois diferentes tempos / In vitro toothbrushing wear evaluation of a resin composite cured by QTH curing unit in two different times

Juan Carlos Pontons Melo 23 March 2009 (has links)
Um dos principais problemas dos materiais restauradores (incluindo a resina composta) é o desgaste por abrasão. Portanto, o objetivo neste trabalho foi avaliar in vitro o desgaste abrasivo por escovação da resina composta 4Seasons, de duas cores diferentes (A3 e C4) e com fotopolimerização por dois diferentes tempos (20 e 40 s), utilizando escova Sorriso, da Colgate, e creme dentifrício Colgate Tripla Ação; também foi usado, como material de referência, o polimetil metacrilato. Assim, foram confeccionados dez corpos-de-prova, para cada um dos cinco grupos formados (PMMA, A3 20s, A3 40s, C4 20s, C4 40s). Cada espécime consistia basicamente num cilindro de cerca de 1,8 mm de altura e 8 mm de diâmetro. Cada espécime, após sua confecção, era imerso em água deionizada, a 37 ± 2 ºC, por 24 horas, quando então eram regularizados com lixa (granulação # 600 e # 1.000); após lavagem com ultrassom, voltavam a ser armazenados nas mesmas condições, até completar-se um período de uma semana. A escovação foi então efetuada numa máquina própria, que comportava dez espécimes simultaneamente, sendo de 3 N a carga de cada escova sobre o respectivo espécime; a velocidade de cada escova era de 18 cm/s, com a freqüência (ida e volta, num percurso total de 4 cm) de 4,5 ciclos/s; o período de escovação de um espécime compreendia 150. 000 ciclos. Foram efetuados cinco períodos (ou lotes) de escovação, de modo que um espécime do material de cada grupo tivesse sido submetido à ação de cada uma das posições ocupadas pelas dez escovas. A quantidade de massa perdida, para cada espécime, foi calculada por meio de pesagem (pré e pós escovação), numa balança com acuidade de milionésimo de grama. O trabalho foi também ilustrado com gráficos de rugosidade e com fotomicrografias tomadas ao MEV. A taxa média de desgaste foi de 2,8 mg para o PMMA, de 5,5 mg para o A3-20s, 4,7 mg para o A3-40 s, 5,4 para o C4-20s e 4,2 mg para o C4-40s; a respectiva análise de variância mostrou não existir diferença significante entre os grupos, para p=0,166; o coeficiente de variação entre os grupos foi bastante semelhante. Foi possível concluir que não existiu diferença da resistência ao desgaste abrasivo entre os grupos estudados. / One of the main problems of dental restorative materials (including the resin composites) is the abrasion wear. Therefore, the aim of this work was to evaluate in vitro the abrasive wear by toothbrushing of the resin composite 4Seasons, of two different colors (A3 and C4), cured by two different times (20 and 40 s), using a toothbrush (Sorriso - Colgate), and a dentifrice (Tripla Ação Colgate). Polimetil meth-acrylate was used as reference material. Ten cylindric samples (approximately 1.8 mm height and 8 mm diameter) had been prepared for each one of the five evaluated groups (PMMA, A3 20s, A3 40s, C4 20s, C4 40s). After confection, samples were immersed in deionized water, at 37 ± 2ºC, for 24 h, and then regularized by abrasive gritting with sandpaper (from #600 to # 1 000); after that, were cleaned in ultrasound bath, and restored to the same described conditions, until completing the period of one week. The toothbrushing was then conducted in a proper machine that holds 10 specimens simultaneously, with a 3 N load of each toothbrush on the respective sample. The speed of each toothbrush was of 18 cm/s, at a frequency of 4.5 cycles/s (each cycle consisting of 2 cm forward and 2 cm backward). 150. 000 cycles were applied per sample. Five periods (or lots) of toothbrushing had been performed, in a way that one sample of each group had been submitted to the brushing action at one position in the machine. The amount of weight loss for each sample was calculated by means of weighting (before and after toothbrushing), in an analytical balance with accuracy of millionth of gram. Roughness and MEV photomicrographies were also evaluated. The average rate of wear was of 2.8 mg for PMMA, 5.5 mg for A3-20s, 4.7 mg for A3-40 s, 5.4 for C4-20s, and 4,2 mg for C4-40s. One-way ANOVA showed no significant difference between groups (p = 0.166). The coefficient of variation between the groups was sufficiently similar. It was possible to conclude that difference of the resistance to the abrasive wear between the studied groups did not exist.
86

O papel da concentração de nanofibras e da composição da matriz resinosa nas propriedades flexurais de compósitos experimentais baseados em nanofibras / Flexural properties of experimental nanofiber reinforced composite are affected by resin composition and nanofiber/resin ratio

Hugo Alberto Vidotti 09 November 2015 (has links)
O objetivo do presente estudo foi de avaliar a influência de soluções de resina com diferentes proporções de monômeros e diferentes concentrações em massa de nanofibras nas propriedades flexurais de compósitos resinosos experimentais reforçados com nanofibras de poliacrilonitrila (PAN). Materiais e métodos: Nanofibras de PAN foram produzidas pelo processo de eletrofiação e caraterizadas por teste de tração e microscopia eletrônica de varredura (MEV). Os compósitos experimentais foram produzidos pela infiltração das mantas de nanofibras com diferentes misturas de BisGMA-TEGDMA (BisGMA/TEGDMA: proporções em % massa de 30/70, 50/50, e 70/30). Foram incorporadas diferentes concentrações em massa de nanofibras (de 0% a 8%). Espécimes em forma de barra foram seccionados a partir de blocos do compósito experimental e armazenados em água na temperatura de 37oC por 24h anteriormente à realização dos testes de flexão de três pontos. Foram avaliados a resistência flexural (RF), o módulo flexural (MF) e o trabalho de fratura (TF). Resultados: Os testes de tração das nanofibras de PAN demonstraram um comportamento anisotrópico das mantas de nanofibras. As propriedades mecânicas exibiram maiores valores na direção perpendicular ao eixo de rotação do coletor metálico utilizado na produção das fibras por eletrofiação. Maiores proporções de BisGMA nas misturas de resina resultaram em maiores valores de RF e MF, o que não ocorreu para os valores de TF. A adição de diferentes concentrações de nanofibras não afetou as propriedades de RF e MF em comparação com o grupo controle (resina pura) (p>0.05). No entanto, a adição das nanofibras promoveu um aumento significante do TF, principalmente para as misturas de resina com maior proporção de TEGDMA (p<0,05). Significância: A inclusão de nanofibras de PAN em resinas de modo a formar compósitos resinosos reforçados por nanofibras não afetou negativamente as propriedades flexurais do material e resultou em um aumento significativo da tenacidade, uma propriedade desejável para um material a ser utilizado para aplicação restauradora. / The present study had the objectives to evaluate the influence of different resin blends concentrations and nanofibers mass ratio on flexural properties of experimental Poliacrylonitrile (PAN) nanofibers reinforced composite. Materials and Methods: Poliacrylonitrile (PAN) nanofibers mats were produced by electrospinning and characterized by tensile testing and scanning electron microscopy (SEM). Experimental resin-fiber composite beams were manufactured by infiltrating PAN nanofiber meshs with varied concentrations of BisGMA-TEGDMA resin blends (BisGMA/TEGDMA: 30/70, 50/50 and 70/30 weight %). The mass ratio of fiber to resin varied from 0% to 8%. Beams were cured and stored in water at 37oC. Flexural strength (FS), flexural modulus (FM) and work of fracture (WF) were evaluated by three-point bending test after 24 hs storage. Results: The tensile properties of the PAN nanofibers indicated an anisotropic behavior being always higher when tested in a direction perpendicular to the rotation of the collector drum. Except for WF, the other flexural properties (FS and FM) were always higher as the ratio of BisGMA to TEGDMA increased in the neat resin beams. The addition of different ratios of PAN fibers did not affect FS and FM of the composite beams as compared to neat resin beams (p>0.05). However, the addition of fibers significantly increased the WF of the composite beams, and this was more evident for the blends with higher TEGDMA ratios (p<0.05). Significance: The inclusion of PAN nanofibers into resin blends did not negatively affect the properties of the composite and resulted in an increase in toughness that is a desirable property for a candidate material for restorative application.
87

"Estudo da influência do tratamento por calor em propriedades mecânicas de resinas compostas" / Influence of heat treatment on the mechanical properties of resin composites

Ivone Lima Santana 08 December 2005 (has links)
O objetivo deste trabalho foi o de avaliar o efeito de tratamentos por calor nas propriedades mecânicas de resistência flexional e microdureza Knoop de três marcas comerciais de resinas compostas para uso direto (FillMagic, P60 e TPH), na condição de incluída ou não em revestimento durante um tratamento térmico (calor seco/170°C), por três períodos (5, 10 e 15 min). A temperatura adotada para os tratamentos foi baseada em análises prévias (termogravimetria e calorimetria exploratória diferencial) com a finalidade de se determinar a temperatura de início de perda de massa e de transição vítrea das resinas. Os corpos-de-prova (n=7) foram confeccionados com o auxílio de uma matriz metálica (10 mm x 2 mm x 2 mm), sendo o compósito inserido em bloco único e irradiado numa única superfície (600mW/cm 2 por 40s). Foram obtidos, no total, sete grupos experimentais por resina, sendo o controle a condição de apenas fotoativada. Os espécimes foram submetidos ao ensaio de resistência à flexão, com distância entre apoios de 8 mm, em uma velocidade constante de 0,5 mm/min e célula de carga de 1000N. A dureza Knoop foi obtida com carga de 100 g e tempo de penetração de 15 s. As médias de resistência flexional, em MPa, foram de 174,80 para a resina FillMagic, 182,64 para a P60 e 172,22 para a TPH. Na mesma ordem, as médias de microdureza Knoop foram de 73,1; 102,0 e 74,0.A análise de variância dos resultados obtidos permitiram concluir que os tratamentos experimentais aumentaram a resistência flexional das resinas indistintamente. Os valores de microdureza também aumentaram, mas houveram diferenças de suscetibilidade ao tratamento térmico entre as resinas / The aim of this study was to assess the effect of heat treatment on mechanical properties of flexure strength and Knoop micro hardness of three commercially available brands of resin composites for direct use (FillMagic, P60 and TPH) included or not in investments during heat treatment (dry heat/170ºC) by three periods (5, 10 and 15 min.) The temperature adopted for the treatments was based on previous analysis (thermo gravimetric and differential exploratory heating) in order to determine the initial temperature of mass loss and glass transition of resin composites. The samples (n=7) were prepared with a metallic matrix (10 mm x 2mm x 2mm) in which the resin composite was inserted in a single block and only one surface was irradiated (600mW/cm 2 40s). Seven experimental groups were obtained for each resin composite in which the control group was solely light-cured. The flexure strength test was performed with a support distance of 8 mm, cross-head speed of 0.5 mm/min. and 1000 N load. Knoop micro hardness was obtained with a load of 100 g and penetration time of 15 s. The flexure strength averages in MPa were 174.80 for FillMagic, 182. 64 for P60 and 172. 22 for TPH. Thus, Knoop micro hardness means were 73.1; 102.0 and 74.0. The analysis of variance indicated that the experimental treatments increased flexure strength of resin composites. Micro hardness values also increased, but there were differences in the resin composites susceptibility to the heat treatment
88

Desenvolvimento de tensões de polimerização determinado através do método da propagação de trincas / Development also polymerization stress determined by crack analysis methods

Thayse da Costa Guimarães 30 August 2013 (has links)
O objetivo do presente estudo foi avaliar o desenvolvimento das tensões de polimerização de um compósito resinoso restaurador ao longo das primeiras 24 horas após a fotoativação, segundo dois métodos de análise da propagação de trincas. A influência do armazenamento em água sobre a magnitude das tensões também foi avaliada. O grau de conversão (GC) e o módulo de elasticidade (E) do compósito foram determinados nos diferentes tempos de observação. As hipóteses nulas do trabalho foram: 1) tensão de polimerização, GC e E não variam de forma significativa ao longo do período de observação; 2) os dois métodos de análise de propagação de trincas fornecem resultados semelhantes; 3) os valores de tensão não são influenciados pelo meio de armazenamento. Foram confeccionados discos de vidro de soda-cal com 2 mm de espessura, diâmetro externo de 12 mm, com perfuração central de 4 mm de diâmetro. Os discos foram aleatorizados em três grupos. Em um deles, os discos foram restaurados (Charisma Diamond, Heraeus Kulzer) e, após os tempos de 10 min, 1, 2, 4, 8 ou 24 horas (n=10), os espécimes receberam quatro indentações Vickers, (9,8N por 20s) a 500m da margem da cavidade. O segundo grupo passou pelo mesmo processo, porém os discos ficaram armazenados em água antes de serem indentados. Em seguida, o comprimento das trincas e a diagonal da indentação foram mensurados em microscópio óptico. A tensão residual no vidro foi calculada de acordo com a norma 4-01 (The Society of Materials Science, JSMS, Japão). No terceiro grupo, os discos foram indentados e armazenados em dissecador por 24h antes de serem restaurados. As trincas foram medidas antes e após a restauração, nos mesmos tempos descritos acima, e a tensão calculada de acordo com a fórmula descrita por Yamamoto et al. (Dent Mater, 2009). O GC foi determinado por espectroscopia no infra-vermelho próximo (n=3). O E foi obtido através do teste de dobramento em três pontos (n=10). Os dados foram submetidos a ANOVA/Tukey (=0,05) e análise de regressão. A tensão de polimerização, assim como o GC e o E tiveram seus valores aumentados ao longo do tempo. O GC aumentou 28% entre 10 minutos e 24 horas, para o E houve um aumento de 1,7 GPa para 6,3 GPa entre 10 minutos e 24 horas. A tensão de polimerização aumentou 40% entre 10min e 24h para a norma 4-01 e 51% para o método do Yamamoto et al. O meio de armazenamento foi estatisticamente significativo até o tempo de 4 horas. Portanto, a primeira hipótese foi rejeitada. A segunda e a terceira hipótese podem ser apenas parcialmente rejeitadas. / The objective of this study was to evaluate composite resin restoration polymerization stress development over the first 24 hours after polymerization, according to two methods of analysis of crack propagation. The influence of water storage on the magnitude of the stresses was also evaluated. The degree of conversion (DC) and modulus of elasticity (E) of the composite were determined at various time points. The null hypotheses of this study were: 1) The polymerization stress, DC and E do not change significant throughout the observation period, 2) the two methods of analysis of crack propagation provide similar results, 3) the stress values are not influenced by storage medium. Disks were made of soda-lime glass with 2 mm thickness, 12 mm in outside diameter with central bore of 4 mm in diameter. The perforations were treated with hydrofluoric acid and silane. The discs were randomized into three groups. In one of them, the discs were restored (Charisma Diamond, Heraeus Kulzer), and, the times after 10 min, 1, 2, 4, 8 or 24 hours (n = 10), the specimens received four Vickers indentations (9.8 N for 20 s) at 500m cavity margin. The second group went through the same process, but the discs were stored in water prior to being indented. Then, the length diagonal of the indentation and crack was measured in an optical microscope. The residual stress in the glass was calculated according to standard 4-01 (The Society of Materials Science, JSMS, Japan). The third group of discs were treated similarly, indented and stored in a desiccator for 24 hours before being restored. The cracks were measured before and after the restoration following the same time, and the stress calculated according to the formula described by Yamamoto et al. (Dent Mater, 2009). The DC was determined by near-infrared spectroscopy (n = 3). The E was obtained through the bend test conducted at three-points. Data were subjected by ANOVA / Tukey test ( = 0.05) and regression analysis. The polymerization stress, as well as DC and E values were increased over time. GC increased 28% between 10 minutes and 24 hours, and for an increase of 1.7 GPa to 6.3 GPa between 10 minutes and 24 hours. The polymerization stress increased 40% between 10 min and 24 hours to the standard 4.1 and 51% for the method of Yamamoto et al. The storage medium was statistically significant at the time of 4 hours. Thus, the first hypothesis was rejected. The second and third hypothesis may only be partially rejected.
89

Alteração de cor e rugosidade superficial de resina composta clareada após envelhecimento em função do tempo / Color change and surface roughness of composite resin cleared after accelerated artificial aging as a function of time

Daniela de Biagi Freitas 30 July 2010 (has links)
O presente trabalho teve como objetivo analisar &ldquo;in vitro&rdquo; a alteração de cor e a rugosidade superficial de uma resina composta (Charisma®) submetidas a tratamento clareador com agente clareador Lase Peroxide Sensy® (CC) e grupo controle sem tratamento clareador (SCL), após envelhecimento (EAA) em função do tempo, realizando-se avaliação superficial complementar por meio de Microscopia Eletrônica de Varredura (MEV) e EDX. Os corpos-de-prova (n=15) foram confeccionados com o auxílio de uma matriz de Teflon nas dimensões de 11x2,0mm, polidos com discos Soft Lex®, na seqüência de abrasividade decrescente e armazenados em saliva artificial a 37ºC (±1ºC), até os momentos de serem submetidos aos tratamentos propostos e à realização das leituras de alteração de cor e rugosidade superficial, nos tempos: 24 horas após a confecção (T0), após envelhecimento artificial acelerado (T1), 24 horas após clareamento (T2), 7dias (T3) e 1 mês após clareamento (T4). As leituras de alteração de cor foram obtidas com o auxílio do aparelho Espectrofotômetro (PCB6807BYK GARDNER) e para as leituras de rugosidade superfícial foi utilizado o Rugosímetro Mitutoyo SJ201P. Os dados foram submetidos à Análise de Variância ANOVA (p&le;0,05). Os resultados obtidos foram: a) o fator Tempo teve efeito estatisticamente significante sobre as variáveis &Delta;E* (T1=T2=T3; T1=T4), L* (T0&lt;T1=T2=T3=T4), a* (T0&gt;T1=T2; T1=T3=T4; T4&gt;T2), b* (T0&gt;T1=T2=T3; T4=T3=T1; T2&lt;T4) e rugosidade superficial (&mu;m) (T0&lt;T1,T2,T3,T4; T1=T2; T1&lt;T3=T4; T2=T3=T4; b) para o fator tratamento com relação a &Delta;E* e fator L*(CC&gt;SCL), para os fatores a* e b*(CC&lt;SC), c) a interação Tratamento x Tempo não apresentou diferença estatisticamente significante para as variáveis &Delta;E*, L*, a*, b* e rugosidade superficial, d) as superfícies após EAA apresentaram alterações d) não houve mudanças no EDX antes e após os tratamentos. Conclui-se que a resina Charisma®, apresentou alteração de cor (&Delta;E*&gt;3,3) e uma estabilidade na rugosidade superficial a partir de T2. / The current study in vitro evaluated the color change and surface roughness of the composite resin Charisma® cleared with Lase Peroxide Sensy® (CCL) and control without bleaching (SCL) after accelerated artificial aging (EAA) as a function of time, performing additional surface evaluation by scanning electron microscopy (MEV) and EDX. To obtain the color change and surface roughness a Spectrophotometer (PCB 6807 BYK GARDNER) and rugosimeter (Mitutoyo SJ- 201P) were employed respectively. Measurements were carried out at five times: 24 hours after preparation (T0), after artificial accelerated aging (T1), 24 hours after bleaching (T2), 7days (T3) and 1 month after bleaching (T4). The specimens (n=15) were prepared with aid of a Teflon (10-mmin diameter and 2mm thick). The specimens were polished with discs Soft Lex®, following abrasiveness decreased, being stored in artificial saliva at 37ºC (±1ºC) until the time of undergoing the proposed treatments and the measurements. The data obtained were submitted to ANOVA parametric test (p &le; 0.05). The results were: a) time factor had a statistically significant effect on the variables &Delta;E* (T1 = T2 = T3, T1 = T4), L*(T0 &lt;T1 = T2 = T3 = T4), a* (T0 &gt; T1 = T2; T1=T3 =T4, T4&gt;T2), b* (T0&gt; T1=T2=T3, T4=T3=T1; T2&lt;T4) and roughness(&mu;m) (T0&lt;T1,T2, T3,T4; T1 = T2; T1&lt;T3=T4; T2=T3=T4), b) for treatment factor &Delta;E* and L* (CC&gt; SCL) for the factors a*and b* (CC &lt;SC), c) Treatment x Time interaction showed no statistically significant difference for the variables &Delta;E*, L*, a*, b* and surface roughness, d) after EAA the surfaces change d) before and after EAA dont have changes. It is concluded that the resin Charisma®, presented color change (&Delta;E *> 3.3) and surface roughness stability from T2.
90

"Avaliação por espectroscopia Raman da união dos materiais adesivos à dentina utilizando digluconato de clorexidina 2% para limpeza cavitária"

Paula , Giseli Carvalho de 28 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-11T13:58:17Z No. of bitstreams: 1 giselicarvalhodepaula.pdf: 1937996 bytes, checksum: 3de1145ff4d14de67b2087792ed59efe (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-11T15:06:35Z (GMT) No. of bitstreams: 1 giselicarvalhodepaula.pdf: 1937996 bytes, checksum: 3de1145ff4d14de67b2087792ed59efe (MD5) / Made available in DSpace on 2015-12-11T15:06:35Z (GMT). No. of bitstreams: 1 giselicarvalhodepaula.pdf: 1937996 bytes, checksum: 3de1145ff4d14de67b2087792ed59efe (MD5) Previous issue date: 2015-04-28 / Este estudo teve como propósito analisar o efeito da utilização de Digluconato de Clorexidina a 2% como agente de limpeza cavitária antes da aplicação do sistema adesivo convencional na difusão resinosa e no padrão de distribuição da matriz de colágeno na hibridização. Foram realizadas cavidades classe V nas faces vestibulares de vinte dentes pré-molares humanos hígidos que foram divididos em 2 grupos. No Grupo 1: os dentes foram tratados com o sistema adesivo convencional de acordo com as instruções do fabricante e o grupo 2: o Digluconato de Clorexidina 2% foi aplicado na superfície dentinária depois do condicionamento ácido, por 30 segundos e seco com um breve jato de ar. Cada dente foi restaurado com resina composta fotopolimerizável nanoparticulada. Os corpos de prova foram seccionados e as interfaces adesivo/resina foram analisadas por Espectroscopia Raman. As medidas de difusão dos componentes monoméricos e distribuição de colágeno foram avaliadas pelas bandas Raman de 1667 cm-1; 1273 cm-1; 1242 cm-1; 1720 cm-1; 1453 cm-1. O gradiente de desmineralização usado na determinação da região de hibridização foi avaliado pela banda de 960 cm-1 da hidroxiapatita da dentina peritubular. De acordo com os resultados obtidos, a aplicação de Digluconato de Clorexidina favoreceu a reidratação da trama de fibras colágenas da dentina, reexpandindo-as melhorando a qualidade da camada híbrida. / This study aimed to analyze the effect of using Chlorhexidine Digluconate 2% as cavity cleaning agent before applying the conventional adhesive system to resinous dissemination and distribution pattern of the collagen matrix in the hybridization. Class V cavities were performed on the buccal surfaces of twenty premolars healthy human teeth were divided into 2 groups. Group 1: teeth were treated with conventional adhesive systems according to the manufacturers instructions and group 2: Chlorhexidine Digluconate 2% was applied to the dentin surface after etching for 30 seconds and dried with a brief jet air. Each tooth was restored with light-cured composite nanoparticle. The specimens were sectioned and adhesive / resin interfaces were analyzed by Raman Spectroscopy. Diffusion measurements of monomeric components and collagen distribution were evaluated by Raman bands 1667 cm-1; 1273 cm-1; 1242 cm-1; 1720 cm-1; 1453 cm-1. The demineralization gradient used to determine the hybridization region was evaluated by the band of 960 cm-1 hydroxyapatite of peritubular dentin. According to the results obtained, the application of Chlorhexidine Digluconate favored the rehydration of the web of collagen fibers of the dentin, reexpandindo them increasing the hybrid layer.

Page generated in 0.0725 seconds