• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 173
  • 2
  • 1
  • Tagged with
  • 176
  • 176
  • 145
  • 143
  • 37
  • 29
  • 22
  • 21
  • 21
  • 20
  • 20
  • 19
  • 19
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Influência de soluções de clorexidina e de própolis e da simulação de pressão pulpar na resistência de união dentinária / Influence of chlorhexidine and propolis solutions and simulated pulpal pressure in dentin bond strength

Perote, Letícia Carvalho Coutinho Costa [UNESP] 17 February 2016 (has links)
Submitted by LETÍCIA CARVALHO COUTINHO COSTA PEROTE (leticiaccc@gmail.com) on 2016-04-08T17:53:49Z No. of bitstreams: 1 Tese biblioteca finalizada.pdf: 4785988 bytes, checksum: 99777155681f63934c41a2cacd0892f3 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-04-11T17:17:19Z (GMT) No. of bitstreams: 1 perote_lccc_dr_sjc.pdf: 4785988 bytes, checksum: 99777155681f63934c41a2cacd0892f3 (MD5) / Made available in DSpace on 2016-04-11T17:17:20Z (GMT). No. of bitstreams: 1 perote_lccc_dr_sjc.pdf: 4785988 bytes, checksum: 99777155681f63934c41a2cacd0892f3 (MD5) Previous issue date: 2016-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência de soluções de clorexidina e de própolis e da simulação de pressão pulpar na resistência de união entre resina e dentina. Para isto, foram obtidos segmentos coronários de 120 dentes humanos. Metade das amostras foram conectadas a um dispositivo de simulação de pressão pulpar, cuja altura foi ajustada para 15 cm de água. Foi realizado condicionamento com ácido fosfórico 37% por 15 s, lavagem e secagem com papel absorvente. Em seguida, foram divididas em 3 grupos, de acordo com a solução aplicada por 30 s: GC(Grupo Controle – nenhuma solução), CLX (Digluconato de Clorexidina 0,2%), PA (Extrato de própolis aquoso). Aplicou-se o adesivo (Single Bond Universal) e resina composta (Filtek Z250) em todos as amostras. Os grupos foram subdivididos de acordo com o tipo de envelhecimento: I (Corte Imediato), C (15000 ciclos térmicos). As amostras foram cortadas em palitos e submetidas ao teste de microtração. Os dados obtidos de resistência de união (MPa) foram submetidos ao teste de ANOVA 3 fatores. Para o fator Solução, não foi encontrada diferença estatisticamente significante entre os grupos (p=0,46), mas sim para os fatores Pressão Pulpar (p=0,00) e Envelhecimento (p=0,00), além das interações entre os fatores Solução e Pressão Pulpar (p= 0,00), Pressão Pulpar e Envelhecimento (p=0,00) e entre os três fatores (p=0,03). Os resultados do teste de Tukey para o fator Pressão Pulpar foram: CPP (com pressão pulpar): 29,19a, SPP (sem pressão pulpar): 32,98b; e para o fator Envelhecimento foram: C (ciclados): 28,12a, I (imediato): 34,05b. Concluiu-se que as soluções de clorexidina e de própolis não interferiram na resistência de união; e que a simulação de pressão pulpar e a termociclagem diminuíram os valores de resistência de união da resina à dentina. / This study aimed to assess the influence of chlorhexidine and propolis solutions and simulated pulpal pressure on the bond strength between resin and dentin. To do so, crown segments of 120 human teeth were obtained. Half of the samples were connected to a pulp pressure simulation device, adjusted to 15 cm H2O. Conditioning was accomplished with 37% phosphoric acid for 15 seconds, washing and drying with absorbing paper. Then, samples were split into 3 groups, according to the solution applied for 30 s: GC (Control group – no solution), CLX (Chlorhexidine digluconate 0.2%), PA (Aqueous propolis extract). Single Bond Universal adhesive and composite resin (Filtek Z250) were applied in all samples. Groups were subdivided according to the aging process: I (Immediate cut) and T (15000 thermal cycles). Samples were cut into beams and went through microtensile bonding tests. Bond strength data (MPa) were analyzed by three-way ANOVA. For the factor Solution, there was no statistically significant difference among the groups (p = 0.46), but was found difference for the factors Pulpal Pressure (p=0.00), Aging (p=0.00), and interaction between Solution and Pulpal Pressure (p=0.00), Pulpal Pressure and Aging (p=0.00) and between the 3 factors (p=0.03). The results from Tukey’s test for Pulpal Pressure factor were: SPP (simulated pulpal pressure): 29,19a, NPP (no pulpal pressure): 32,98b; and for the factor Aging were: T (thermal cycling): 28,12a, I (immediate): 34,05b. It was concluded that chlorhexidine and propolis solutions have not interfered in the bond strength; but simulated pulpal pressure and termal cycling reduced the dentin bond strength.
72

Influência de bebidas e escovação nas propriedades físicas de uma resina composta / Influence of beverages and brushing on the physical properties of a composite resin

Cesar Penazzo Lepri 23 January 2009 (has links)
Objetivo: Este estudo avaliou a influência de bebidas e escovação na estabilidade de cor, rugosidade superficial e microdureza em profundidade de uma resina composta. Materiais e Método: 120 discos (10mm de diâmetro X 2mm de espessura) de resina composta (Filtek- Z250) foram preparados e polidos após 24 horas. A cor inicial e a rugosidade superficial inicial foram mensuradas e os espécimes foram divididos aleatoriamente em quatro grupos (vinho tinto, refrigerante, aguardente, ou saliva artificial controle) e três subgrupos (sem escovação; escovação com Colgate, ou escovação com Close Up Whitening). Os espécimes foram imersos na sua respectiva solução, 5x ao dia, por 5 minutos, durante 30 dias, sendo dois subgrupos escovados ao final de cada dia (120 movimentos/dia). A cor foi mensurada no 15º e no 30º dia de imersão; a rugosidade superficial final foi medida no 30º dia. Após o período de imersão, os espécimes foram armazenados em saliva artificial por 7 dias, quando a superfície dos mesmos foi polida e imediatamente realizou-se uma mensuração de cor. A alteração de cor foi mensurada com um espectrocolorímetro e analisada pelos valores de ΔE, ΔL, Δa, e Δb. Os valores de rugosidade (Ra-μm) foram medidos com um rugosímetro. Com relação à microdureza, os espécimes primeiramente foram incluídos em resina de poliéster e seccionados no sentido transversal. Após o polimento destas superfícies, foram realizadas mensurações nas profundidades de 30μm, 60μm, 90μm, 120μm e 250μm, empregando os parâmetros 25gf/40s de microdureza Knoop. Os dados foram submetidos à ANOVA e teste de Fisher\'s (α=5%). Resultados: Os valores de alteração de cor foram estatisticamente diferentes após a imersão nas bebidas; o vinho tinto promoveu a maior alteração, seguido pelo refrigerante e aguardente, que foram similares entre si e diferentes da saliva artificial. Nenhuma diferença foi observada com ou sem escovação, independentemente do dentifrício utilizado. Ao 30º dia, os espécimes apresentaram uma mudança de cor mais intensa do que ao 15º dia, após o repolimento, a cor dos espécimes foi similar à cor do 15º dia. As bebidas e a escovação influenciaram negativamente na rugosidade da superfície. Em relação à microdureza, não houve diferença significativa entre os grupos, independentemente da profundidade analisada. Conclusões: A mudança de cor da resina composta foi influenciada apenas pelas bebidas; a escovação não afetou a propriedade analisada. O repolimento não foi suficiente para promover o retorno da cor dos espécimes aos valores iniciais. A rugosidade superficial foi influenciada negativamente tanto pelas bebidas quanto pela escovação. Para a microdureza, a resina composta apresentou resultados similares independentemente das bebidas utilizadas e da presença ou ausência de escovação nos espécimes avaliados. / Objective: This study evaluated the influence of beverages and brushing on the color change, surface roughness and microhardness in depth of a composite resin. Methods: 120 composite resin disks (10mm-øX2mm-thickness; Filtek-Z250) were prepared and polished after 24h. Initials color and surface roughness were measured and specimens were randomly assigned into four groups (red wine, soft drink, sugar cane spirit, or artificial saliva control) and three subgroups (without brushing; brushing with Colgate, or brushing with Close Up Xtra Whitening). Specimens were immersed in the beverage 5x/day, for 5 minutes, over 30 days, being two subgroups brushed at the end of every day (120 moving/day). Color was measured at the 15th and 30th days of immersion; final surface roughness was measured at the 30th day. After the immersion period, specimens were stored in artificial saliva for 7 days, when their surfaces were repolished and immediately assessed by color. Color change was measured with a spectrocolorimeter and analyzed by ΔE, ΔL, Δa, and Δb values. The values of roughness (Ra - μm) were measured with a rugosimeter. As regard microhardness, the specimens were firstly included in polyester resin and sectioned in the transverse direction. After polishing these surfaces, measurements were realized at depths of 30μm, 60μm, 90μm, 120μm and 250μm, employing the parameters 25gf/40s of microhardness Knoop. Data were submitted to ANOVA and Fisher\'s tests (α=5%). Results: Color change values were statistically different after immersion in the beverages; red wine promoted the highest alteration, followed by soft drink and sugar cane spirit, which presented similar results among them and different from saliva. No difference was observed with or without brushing independently of the toothpaste used. At 30th day, specimens exhibited a color change higher than 15th day; after repolishing, the color of the specimens was similar to 15th day. Beverages and brushing negatively influenced the surface roughness. In relation to microhardness, there was no significant difference among groups, regardless of the depth examined. Conclusions: Color change of the composite resin was influenced only by the beverages and brushing did not affect the analyzed property. The repolishing was not sufficient to promote the return of the specimens color to their initial values. The surface roughness was negatively influenced both by the beverage as brushing. For microhardness, the composite resin showed similar results regardless of the beverages used and the presence or absence of brushing in the specimens tested.
73

Avaliação da influência do material obturador na resistência de união de retentor intrarradicular pré-fabricado fixado com resina, em dentes fragilizados, por meio do teste de push-out e MEV / Evaluation of the influence of filling material in the bond strength of a fiber-reinforced post fixed with composite resin in weakened teeth, by push-out test and SEM

Cid Alonso Manicardi 11 March 2010 (has links)
Normalmente, a restauração de dentes tratados endodonticamente e com extensa destruição corono-radicular é um desafio para o clínico. Devido à facilidade de manipulação, resinas compostas fotoativadas têm se apresentado como boa opção para o reforço intrarradicular destes dentes, antes da fixação de pinos. O objetivo desta pesquisa foi avaliar ex vivo a possível interferência de materiais obturadores no reforço interno de raízes fragilizadas restauradas com pinos de fibra e resina composta, por meio do teste de push-out e posterior análise da interface dentina/resina/cimento/pino em microscopia eletrônica de varredura (MEV). Cinquenta caninos superiores tiveram suas coroas removidas e o remanescente dental padronizado em 17 mm de comprimento. Após o preparo mecânico-químico, os espécimes foram distribuídos em um grupo controle (n=10) (preparo normal para pino e sem obturação prévia do canal) e um grupo experimental (n=40). Os espécimes do grupo experimental tiveram suas raízes fragilizadas com brocas diamantadas, de forma a apresentar folga circunferencial de aproximadamente 1,0 mm entre o pino e a estrutura dentinária circundante. Em seguida, os espécimes fragilizados foram redistribuídos em quatro subgrupos (n=10) de acordo com o tipo de material obturador: (G1) Endofill + guta-percha; (G2) AH Plus + guta-percha; (G3) Epiphany + guta-percha; (G4): Epiphany + Resilon. Após 24 h, todos os canais foram preparados em 12 mm. A dentina intrarradicular foi então condicionada com ácido fosfórico a 32% (15s), lavada com água deionizada (30s) e secada com pontas de papel absorvente. A seguir, fina camada de um sistema adesivo de 3 passos (All Bond 2) foi aplicada à dentina com pontas microbrush. Para o reforço das raízes, cada canal foi preenchido com uma resina dual Bis-Core e um pino de fibra (DT Light Post) inserido em toda a extensão do preparo. A fotopolimerização foi feita através do pino por 20 s, com a ponta do fotopolimerizador disposta perpendicularmente a ele. Decorridas 24 h, os espécimes foram seccionados transversalmente em fatias de 1 mm de espessura. A resistência de união foi avaliada por meio do teste de push-out e as falhas observadas em estereomicroscópio. Os espécimes foram avaliados quali-quantitativamente em MEV quanto à interface adesiva, presença de camada híbrida e densidade dos tags. A análise estatística da resistência de união dos materiais, em MPa, após o teste de push-out, revelou diferença entre o grupo controle (15,4 ± 6,91) e os grupos experimentais (GI - 11,41 ± 4,66; GII - 9,97 ± 3,41; GIII - 10,12 ± 4,18; e GIV - 9,0 ± 4,17) (ANOVA, post-hoc Tukey test, p<0,05). Contudo, não houve diferença entre os terços as regiões analisadas dentro de cada grupo (p>0,05). Houve maior ocorrência de falhas adesivas tanto no grupo controle quanto nos experimentais. Em MEV, a análise quantitativa mostrou formação de camada híbrida, tags de resina e ramificações laterais em todas as regiões analisadas. Dentro das limitações do presente estudo, concluiu-se que a obturação prévia do canal radicular reduziu a resistência de união do material de reforço intrarradicular, sem diferença estatística entre os tipos de cimentos testados. / The restoration of endodontically treated teeth commonly presents a challenge in cases of extensive crown-root destruction. Due to their ease of handling, lightactivated composite resins present a better option for intracanal reinforcement before the use of a fiber posts. The aim of this ex vivo study was to evaluate the influence of filling materials in the root reinforcement of weakened experimentally roots restored with composed resin and quartz fiber post by means of push-out bond strength evaluation and scanning electronic microscopy (SEM) analysis of the dentin/resin/cement/post interface. The crowns of 50 upper maxillary canines were removed and the length of roots standardized in 17 mm. After root canal preparation, the specimens were randomly divide into one control (n=10) (normal post preparation with no previous filling) and one experimental groups (n=40). All specimens in the experimental group had their canals enlarged in such a way as to produce a circumferential space of approximately 1.0 mm between the fiber post and the circumjacent dentine walls, using diamond tips. Then, the specimens of the experimental group were subdivided into four subgroups (n=10), according to the filling materials: (G1) Endofill + gutta-percha; (G2) AH Plus + gutta-percha; (G3) Epiphany + gutta-percha; (G4): Epiphany + Resilon. After 24 h of the root canal filling, the canals of all specimens were prepared into 12 mm. The intracanal dentine was etched with 32% phosphoric acid (15s), rinsed with deionised water (30s) and gently dried with absorbent paper points. A 3-step etch-and-rinse adhesive system (All Bond 2) was applied to the slightly moist dentine with disposable microbrush tips. For root reinforcement, each canal was bulk filled with a translucent composite resin (Bis-Core) and a fiber post (DT Light Post) was centrally inserted into the resin mass along the whole post space extension. Light-curing was performed with a conventional device by placing the tip perpendicularly through the post for 20s. After 24 h of the post cementation, the specimens were sectioned perpendicularly to its long axis in 3 slices, with 1 mm of thickness. The bond strength was performed by the push-out test and, after dislodgments, the failures were observed in the stereomicroscope. The specimens were processed for SEM analysis to observe bonding interface formation, hybrid layer quality and resin tag density using a fourstep scale method. The statistical analysis of the bond strength, in MPa, after the push-out test, indicated difference between control (15,4 ± 6,91) and experimental groups (GI - 11.41 ± 4.66; GII - 9.97 ± 3.41; GIII - 10.12 ± 4.18; e GIV - 9.0 ± 4.17) (ANOVA, post-hoc Tukey test, p<0,05), but not between the evaluated regions (p>0.05). The adhesive failures were frequent in the weakened groups as either in the control group. In SEM, the qualitative analysis showed formation of hybrid layer, resin tags and lateral branches in all the analyzed regions, independently of the group. The quantitative analysis (Kruskal-Wallis test, &alpha;=0.05) indicated that previous root canal filling did not influence in the hybrid layer and resin tags formation. Within the limitations of this study, it may be concluded that previous root canal filling have reduced the bond strength in the weakened group, but the type of sealer did not influence in the results.
74

Influência de técnicas de clareamento dental na microdureza superficial e alteração de cor de resinas compostas / Influence of bleaching techniques on the color change and surface microhardness of composites resins

Pedro Turrini Neto 28 March 2008 (has links)
O presente trabalho tem por objetivo avaliar os efeitos do clareamento caseiro, com peróxido de carbamida 10%, e clínico, com peróxido de carbamida 37%, na microdureza e alteração de cor de duas resinas compostas (Z250 e Supreme). Foram confeccionados 100 espécimes, 60 para microdureza e 40 para alteração de cor, com 6mm de diâmetro e 2mm de espessura, em resina composta. A matriz foi preenchida em um único incremento e polimerizada por 20s. Na seqüência os espécimes foram polidos com lixas #1200 e com pasta diamantada. Realizou-se então a primeira medição de dureza e cor dos espécimes. A seguir, para o estudo de cor foi realizada o manchamento com café durante 7 dias e então realizado uma segunda medição da cor. Os espécimes foram divididos aleatoriamente em 3 grupos para microdureza e 2 grupos para cor (n=10) de acordo com o tratamento clareador. Para o clareamento clínico foram realizadas três sessões com intervalo de 7 dias entre elas. Para o clareamento caseiro foram feitas 4h de aplicações diárias durante 14 dias. Nos intervalos entre os procedimentos de clareamentos os espécimes foram armazenados em saliva artificial a 37ºC. Após o final do clareamento nova medição de microdureza e cor foram realizadas. Os dados obtidos foram submetidos ANOVA e Fisher (p<0,05). Para a microdureza os dados revelaram que a Z250, o tratamento clínico e antes do tratamento apresentaram valores estatisticamente superiores aos demais. Na análise da cor pode-se observar que &Delta;E e &Delta;b apresentaram diferenças significativas para os fatores material, tratamento e entre os grupos, para o &Delta;L a Z250 apresentou-se mais escura que a Supreme. Na comparação do clareamento como o padrão observou-se não haver diferenças significativas entre o &Delta;E e &Delta;L para nenhum fator, porém diferenças significativas apresentaram-se para o &Delta;a e &Delta;b para os fatores material e tratamento. Pode-se concluir que os dois métodos de clareamento foram eficientes em clarear os espécimes a valores próximos ao padrão, sendo mais efetivo o clareamento clínico sem alterar a dureza dos materiais e tendo a Supreme apresentado melhor comportamento que a Z250 no retorno da coloração inicial. / The aim of this study was to evaluate the effects of home bleaching (10% carbamide peroxide) and in office bleaching (37% carbamide peroxide) on the color alteration and microhardness of two composite resins (Z250 and Supreme). For this purpose, it was prepared 100 specimens of resin, 60 for microhardness and 40 for color alteration, with 6mm diameter X 2mm thickness. The matrix was filled in a single increment and the resin was light cured for 20s. Specimens were polished after 24 hours with sandpaper #1200 and diamond paste. In this moment, the first color measurements (standard) and also microhardness measurements were realized. After, in the color study specimens were immersed in coffee for a seven days period, subsequently, a second color measurement was realized. Specimens were randomly divided in three groups for microhardness and two groups for color alteration (n=10) according to bleaching treatment. For the office bleaching were realized in 3 sessions with interval of 7 days among them, and every session were realized 3 applications of the bleach agent for 20 min. For the home bleaching, it was done daily applications with 4h duration by 14 days. Specimens were kept in artificial saliva at 37ºC ± 1ºC during intervals between the bleaching proceedings. A new microhardness and color measurements were realized in the end of the bleaching cycle. Data were submitted to ANOVA and Fisher test (p<0.05) and in relation to microhardness showed that Z250 (material), in office bleaching (treatment) and before bleaching (time) presented higher statistically significant values comparing to the others results. For color alteration showed that &Delta;E and &Delta;b were statistically significant differences for the following factors: material, treatment and interactions, for &Delta;L values, Z250 presented darker than Supreme. In the comparison of bleaching with the standard values, it was not observed statistically significant difference between &Delta;E e &Delta;L for all factors; however, it was observed significant difference to &Delta;a and &Delta;b for the factors material and treatment. It can be concluded that both methods of bleaching were efficient in brightness specimens to values near from standard. Furthermore, in office bleaching was more effective without change materials micro hardness and Supreme presented better behavior than Z250 in relation to return to initial color.
75

Eficiência de três cimentos de ionômero de vidro como dissipadores de cargas em bases de restaurações de resina composta: análise por meio da extensometria elétrica

Rocha, Daniel Maranha da [UNESP] 11 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-11Bitstream added on 2014-06-13T18:07:51Z : No. of bitstreams: 1 rocha_dm_me_sjc.pdf: 304438 bytes, checksum: e92fc33799e2997ce037c7a5b7a8994b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo neste estudo foi analisar, por meio da extensometria elétrica, a eficiência dos cimentos de ionômero de vidro convencionais e modificados por resina composta como dissipadores de cargas em restaurações de resina composta. Em matrizes de poliuretano foram colados, dois strain gauges, de modo que suas superfícies superiores tangenciassem a parede de fundo da matriz de ambos os lados (esquerdo e direito). Foram confeccionados 10 corpos de prova em cada grupo num total de 40, sendo no Grupo 1: preenchimento total com resina composta microhíbrida (Opallis); Grupo 2: colocação de uma base de 3mm de cimento de ionômero de vidro convencional (Maxxion R) e preenchimento com resina composta; Grupo 3: colocação de uma base de 3mm de cimento de ionômero de vidro para forramento (Vidrion F) e preenchimento da cavidade com resina composta, e; Grupo 4: colocação de uma base de 3mm de cimento de ionômero de vidro modificado por resina composta (Vitremer) e preenchimento da cavidade com resina composta. Os corpos de prova foram posicionados numa máquina universal de ensaios (EMIC) na qual sofreram uma carga de 50 N no período de 30 s, a uma freqüência de 10 Hz, totalizando 300 leituras por strain gauge. Os dados dos dois sensores foram captados por um amplificador de sinais elétricos e, posteriormente, analisados por um software Os dados coletados foram analisados estatisticamente pelos testes ANOVA e Tukey (p? 0,05), e não apresentaram diferenças estatisticamente significantes. Pode-se concluir que a presença do CIV como material de base de restaurações de resina composta, bem como os tipos de cimento utilizados não apresentaram alterações nos valores de microdeformação. / The aim of this study was to use the strain gauge method to analyze in vitro the efficiency of conventional and resin modified glass ionomer cements as occlusal load dissipaters in composite restorations. Two strain gauges were bonded to polyurethane matrixes with cyanoacrylate adhesive, so that their top surfaces would be tangential to the bottom wall of the matrix on both sides (left and right). For each group, 10 test specimens were made, 40 specimens in total. In Group 1: the cavities were completely filled with microhybrid composite resin; Group 2: filled with conventional glass ionomer cement and microhybrid composite; Group 3: filled with conventional glass ionomer cement for lining and microhybrid composite; Group 4: filled with resin modified glass ionomer cement and microhybrid composite. The test specimens were placed in a universal test machine EMIC, and subjected to a 50 N load for 30 s. Monitoring was done ten times every second, thus providing 300 readings per strain gauge. Data from the two strain gauges were amplified and transferred with an electrical signal amplifier, and then recorded to be analyzed later by special AqDados software. The data collected were statistically analyzed by ANOVA and the Tukey tests (p? 0,05). The mean microdeformation values found for the experimental groups showed no statistically significant difference. From the data obtained in this study, it could be inferred that the presence of GIC as a base material for resin composite restorations, and also the types of cements used presented no significant alterations in the microdeformation values.
76

Avaliação dos efeitos causados por diferentes sistemas de clareamento dental sobre a estrutura superficial do esmalte e resina composta restauradora

Daniel, Carolina Pratti [UNESP] 08 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-08Bitstream added on 2014-06-13T19:51:22Z : No. of bitstreams: 1 daniel_cp_me_arafo.pdf: 928206 bytes, checksum: 591da8085d6b598e522141b55ce7e48c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo deste estudo foi avaliar as alterações de microdureza, rugosidade e morfologia superficial do esmalte e da resina composta após diferentes técnicas de clareamento dental. Para isto, incisivos bovinos foram selecionados, sendo confeccionadas cavidades padronizadas na face vestibular, as quais foram restauradas com resina composta. Os dentes foram distribuídos em grupos (n=6), de acordo com o tratamento proposto: G1- clareamento com gel de peróxido de carbamida (PC) 10%; G2 - clareamento com gel contendo 38% peróxido de hidrogênio (PH); G3- clareamento com gel contendo 38% de PH associado à irradiação com luz. Para G1, o agente clareador foi aplicado por 8 horas diárias durante 21 dias. Para G2 e G3, foram realizadas 3 sessões, compostas por 3 aplicações do gel clareador por 15 minutos, com intervalos de 7 dias entre as sessões, sendo que em G3 foi aplicada luz LED (470nm) por 6 minutos. Durante o intervalo das aplicações do gel clareador, todos os espécimes foram armazenados em saliva artificial. A microdureza Knoop do esmalte e da resina composta foi avaliada antes do procedimento clareador e nos períodos de 1, 7, 14 e 21 dias pós-clareamento. A rugosidade superficial foi analisada por meio de um rugosímetro e a morfologia superficial por um microscópio de força atômica. Os dados foram analisados pelos testes de Mann-Whitney e Wilcoxon. Observou-se diminuição significante na dureza do esmalte para G2 e G3 após a 2ª e 3ª sessões, respectivamente, em relação à dureza inicial (p<0,05). Para a resina composta, esta alteração foi observada em G1 apenas após 21 dias, e em G2 e G3 após a 3ª sessão (p<0,05). Alterações significantes na rugosidade e morfologia superficial foram observadas apenas para o esmalte do grupo G1 (p<0,05). Concluiu-se que o gel com 10% de PC... / The aim of this study was to evaluate changes in microhardness, roughness and surface morphology of enamel and composite resin after different techniques of tooth bleaching. Standardized cavities prepared on the buccal surface of bovine incisors were restored with composite resin. The teeth were divided into groups (n=6) according to the following treatments: G1 - bleaching with 10% carbamide peroxide (CP) gel; G2 - bleaching with 38% hydrogen peroxide (HP) gel; G3 - bleaching with 38% PH gel associated to light irradiation. In G1, the whitening agent was applied for 8 hours daily during 21 days. In G2 and G3, three sessions characterized by three applications of bleaching gel for 15 minutes, with intervals of 7 days between sessions were performed. In G3, the bleaching gel was irradiated with LED (470nm) for 6 minutes. During the intervals among applications of the bleaching gel on enamel, all specimens were stored in artificial saliva. The Knoop microhardness of enamel and composite resin was evaluated before the bleaching procedure and at 1, 7, 14 and 21 days after this treatment. The roughness and superficial morphology (atomic force microscope) were evaluated before and at 21 days after the bleaching procedure. Data were analyzed by Mann-Whitney and Wilcoxon statistical tests. It was observed a significant decrease in hardness of enamel to G2 and G3 after the 2nd and 3rd bleaching sessions, respectively, when compared to the initial enamel hardness (p <0.05). For composites, this change was only observed in G1 after 21-day treatment, and in G2 and G3 after the third bleaching session (p <0.05). Significant changes in roughness and surface morphology of enamel was observed only in G1 (p <0.05). According to the experimental conditions, it was possible to conclude that the bleaching gel with... (Complete abstract click electronic access below)
77

Avaliação dos efeitos causados por diferentes sistemas de clareamento dental sobre a estrutura superficial do esmalte e resina composta restauradora /

Daniel, Carolina Pratti. January 2011 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Flávia Magnani Bevilacqua / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo deste estudo foi avaliar as alterações de microdureza, rugosidade e morfologia superficial do esmalte e da resina composta após diferentes técnicas de clareamento dental. Para isto, incisivos bovinos foram selecionados, sendo confeccionadas cavidades padronizadas na face vestibular, as quais foram restauradas com resina composta. Os dentes foram distribuídos em grupos (n=6), de acordo com o tratamento proposto: G1- clareamento com gel de peróxido de carbamida (PC) 10%; G2 - clareamento com gel contendo 38% peróxido de hidrogênio (PH); G3- clareamento com gel contendo 38% de PH associado à irradiação com luz. Para G1, o agente clareador foi aplicado por 8 horas diárias durante 21 dias. Para G2 e G3, foram realizadas 3 sessões, compostas por 3 aplicações do gel clareador por 15 minutos, com intervalos de 7 dias entre as sessões, sendo que em G3 foi aplicada luz LED (470nm) por 6 minutos. Durante o intervalo das aplicações do gel clareador, todos os espécimes foram armazenados em saliva artificial. A microdureza Knoop do esmalte e da resina composta foi avaliada antes do procedimento clareador e nos períodos de 1, 7, 14 e 21 dias pós-clareamento. A rugosidade superficial foi analisada por meio de um rugosímetro e a morfologia superficial por um microscópio de força atômica. Os dados foram analisados pelos testes de Mann-Whitney e Wilcoxon. Observou-se diminuição significante na dureza do esmalte para G2 e G3 após a 2ª e 3ª sessões, respectivamente, em relação à dureza inicial (p<0,05). Para a resina composta, esta alteração foi observada em G1 apenas após 21 dias, e em G2 e G3 após a 3ª sessão (p<0,05). Alterações significantes na rugosidade e morfologia superficial foram observadas apenas para o esmalte do grupo G1 (p<0,05). Concluiu-se que o gel com 10% de PC... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate changes in microhardness, roughness and surface morphology of enamel and composite resin after different techniques of tooth bleaching. Standardized cavities prepared on the buccal surface of bovine incisors were restored with composite resin. The teeth were divided into groups (n=6) according to the following treatments: G1 - bleaching with 10% carbamide peroxide (CP) gel; G2 - bleaching with 38% hydrogen peroxide (HP) gel; G3 - bleaching with 38% PH gel associated to light irradiation. In G1, the whitening agent was applied for 8 hours daily during 21 days. In G2 and G3, three sessions characterized by three applications of bleaching gel for 15 minutes, with intervals of 7 days between sessions were performed. In G3, the bleaching gel was irradiated with LED (470nm) for 6 minutes. During the intervals among applications of the bleaching gel on enamel, all specimens were stored in artificial saliva. The Knoop microhardness of enamel and composite resin was evaluated before the bleaching procedure and at 1, 7, 14 and 21 days after this treatment. The roughness and superficial morphology (atomic force microscope) were evaluated before and at 21 days after the bleaching procedure. Data were analyzed by Mann-Whitney and Wilcoxon statistical tests. It was observed a significant decrease in hardness of enamel to G2 and G3 after the 2nd and 3rd bleaching sessions, respectively, when compared to the initial enamel hardness (p <0.05). For composites, this change was only observed in G1 after 21-day treatment, and in G2 and G3 after the third bleaching session (p <0.05). Significant changes in roughness and surface morphology of enamel was observed only in G1 (p <0.05). According to the experimental conditions, it was possible to conclude that the bleaching gel with... (Complete abstract click electronic access below) / Mestre
78

Avaliação da influência do material de confecção das matrizes no teste de conversão monomérica por espectrometria no infravermelho de um compósito / Evaluation of the influence of the mould material on the degree of conversion by infrared spectroscopy of a composite

Adriana Riedlinger Mont'Alverne Bordalo 18 December 2007 (has links)
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante. / This study was undertaken in order to determine, in vitro, the influence of mould material by the degree of conversion in a composite, and assess which of the materials tested was more akin to an array of dentin. The assessment was made by examining the degree of conversion (DC). Three bipartite moulds were made of black Teflon, white Teflon and stainless steel. All of them had 10 mm of diameter and 2 mm of deep. To the control group it was used a bovine central incisor, which had its buccal face leveled off in a sander under refrigeration with help of sandpaper 800. After that, this tooth was prepared in high speed with a diamond bur 2294 (KG Sorensen). This bur is proper for preparing standardized cavities for laboratories tests, and has a flat end with stop. A cavity of 2 mm of deep for 9 mm of diameter was obtained by a low speed that made the walls finished. With a cylindrical carbide bur 2056 (KG Sorensen), through the tooth lingual, a penetration was made until an extremely thin wall of dentin was obtained. Thus, with a needle, a little perforation was made in the center of this dentin. The specimens were made dispensed the restorative material on a single increment. A strip of cellulose was placed on top and a glass slab was pressed on the top. The material was cured during 40 seconds by halogen light, Optilux 501 (Demetron), with 500 mW/cm. Immediately, after cured, the specimens were submitted, on the top and on the bottom, to analyze their degree of conversion by FTIR. For the uncured composite was used the technique of the film leaked and for the cured composite, the technique of the potassium bromide tablet (KBr). Five specimens of each group had been confectioned. In each group, the bottom and top composite of the samples was worn out until if getting of 1,5 the 2,0 mg of dust and mixed with 70 mg of KBr, for attainment of the tablet of KBr. The analysis of FTIR was made. The absorptions selected for the calculation had been 1610 cm-1 and 1637 cm-1, the peaks of the specters of the linkings of aromatical and alifatic carbons, respectively. The data had been treated statistical. It could be concluded that the groups of black Teflon, white Teflon and stainless steel had not presented differences between the degree of conversion of the top and the bottom, whereas the group of the dentin presented greater conversion of the top. Comparing the moulds between them, it could be noticed that in the top, the DC of the bovine tooth is greater that the DC of the stainless steel and black Teflon, the DC of white Teflon is greater that the DC of the stainless steel and black Teflon. The top of the groups of bovine tooth and black teflon been similar. In the bottoms of the specimens, it did not have significant difference between the tested groups. In accordance with the results gotten in the experiment, could be concluded that in the groups of black Teflon, white Teflon and stainless steel it did not have difference between 0 and 2 mm, that is, top and bottom, its means that the material of mould confection did not influence the degree of conversion of the composite. Already for the group of the dentin, the top presented value of bigger conversion, showing that, in this in case that, the material of the matrix intervened with the DC. It can also be perceived that a trend of the white Teflon mould to resemble more the dentin mould, therefore was the only group that presented similarity in the values of DC in the top of the samples. However analyzing the bottom of the samples, all the groups had values of the degree of conversion without significant difference.
79

Avaliação das fendas marginais em restaurações de resina composta com variação de alguns determinanates clínicos / Evaluation of marginal gaps in composite resin restorations with some variation of clinical determinants

Marco Antonio Gallito 28 April 2008 (has links)
O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste t de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de dessensibilizante dentinário (t=-3,062 e p=0,004) e com a remoção do colágeno pelo hipoclorito de sódio (t= -8,808 e p= 0,000). / The objective of this study was to compare through the cracks measurements in the dentin resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000).
80

Influência do acabamento e polimento de resina composta na resistência adesiva à dentina e no ângulo cavo-superficial em esmalte / The influence of finishing and polishing procedures on dentin bond strength of resin composite and at the interface enamel/restoration

Diego Ferreira Regalado 17 August 2007 (has links)
O objetivo desse trabalho foi verificar a influência do procedimento de acabamento e polimento das restaurações de resina composta na resistência adesiva à dentina, através de testes de microtração, assim como, analisar em microscopia eletrônica de varredura a interface dente/restauração no nível do ângulo cavo-superficial. Terceiros molares humanos extraídos e hígidos foram utilizados nesse estudo, após aprovação pelo Comitê de Ética em Pesquisa da FOB-USP. Os dentes foram restaurados com sistema adesivo Solobond M (VOCO) e resina composta Grandio (VOCO) e distribuídos nos seguintes grupos: G1 (controle) - sem acabamento e polimento, G2 - acabamento e polimento imediato, G3 - sem acabamento e polimento e armazenado por sete dias e G4 - acabamento e polimento após sete diasem estufa a 37ºC. Palitos com dimensões de 1mm x 1mm foram obtidos e submetidos a uma força de tração em uma máquina de ensaios universal EMIC à velocidade de 0.5mm/min. Para a análise em microscopia eletrônica de varredura, 20 terceiros molares receberam quatro preparos cavitários com 1mm de diâmetro e 3mm de altura que foram restaurados com o mesmo sistema restaurador utilizado para os testes de resistência adesiva e distribuídos nos mesmos grupos descritos acima. Após a obtenção dos espécimes de cada grupo, os dentes foram metalizados e analisados na interface dente/restauração em microscopia eletrônica de varredura por três examinadores. As médias de resistência adesiva (MPa) e respectivos desvios-padrão foram: G1 - 23,05 (8,62); G2 - 17,34 (6,11); G3 - 21,64 (7,63) e G4 - 18,12 (6,51). Os valores de resistência adesiva submetidos à Anova a um critério e teste de Fisher permitiram concluir que o procedimento de acabamento e polimento das restaurações de resina composta diminuiu significativamente a resistência adesiva à dentina. O teste de Kruskal-Wallis aplicado aos escores obtidos da análise das fendas no ângulo cavo-superficial permitiu determinar que o acabamento e polimento da resina composta não interfere na formação de fendas. / The objective of this study was to verify the influence of finishing and polishing procedures on dentin bond strength of resin composite, and at the interface tooth/restoration using MEV. Recently extracted human third molars were utilized in this study, after approved by ethics and search committee at FOB-USP. The teeth were restored with Solobond M (VOCO) adhesive system and resin composite Grandio (VOCO) and randomized in the follow groups: G1 (control) - no polishing and finishing, G2 - immediate polishing and finishing procedures, G3 - no polishing and finishing and stored for seven days e G4 - polishing and finishing procedures after seven days under water at 37oC. Sticks 1mm x 1mm were obtained and the bonds were then stressed to failure by microtensile forces in a EMIC universal testing machine at a crosshead speed of 0.5 mm/min. Twenty human third molars were prepared with four cavities with 1mm diameter and 3mm height and restored with the same restoration system used for the microtensile tests and were distributed at the same groups and the interface tooth/restoration was analyzed in MEV by three examinators. The means of bond strength (MPa) and respective standard deviation were: G1 - 23.05 (8.62); G2 - 17.34 (6.11); G3 - 21.64 (7.63) e G4 - 18.12 (6.51). The data were analyzed by One-Way Anova and e Fisher´s test. It was possible to conclude that the finishing and polishing procedures of resin composite decrease significantly the bond strength to dentin of the composite restorations. The Kruskal- Wallis test aplicated to gap scores at the tooth/restoration interface allows to determinate that the finishing and polishing procedures of resin composite do not interfere in gap formation.

Page generated in 0.0944 seconds