• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 410
  • 23
  • 23
  • 23
  • 23
  • 16
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 418
  • 418
  • 154
  • 108
  • 99
  • 92
  • 73
  • 50
  • 49
  • 45
  • 40
  • 40
  • 39
  • 36
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Avaliação in vitro de propriedades mecanicas e quimicas de uma resina autopolimerizavel polida quimicamente, submetida a um ciclo de polimerização complementar com energia de microondas ou agua quente

Mello, Jose Antonio Nunes de 23 June 1999 (has links)
Orientador: Altair A. Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T05:46:32Z (GMT). No. of bitstreams: 1 Mello_JoseAntonioNunesde_M.pdf: 3694563 bytes, checksum: beacf7b79afd8dcaa091933c87f0830e (MD5) Previous issue date: 1999 / Resumo: o monômero residual em excesso pode causar reações inflamatórias na mucosa além de alterar as propriedades mecânicas da resina. O objetivo desse estudo foi avaliar o efeito do aquecimento pelas microondas e água quente no nível de monômero residual de uma resina acrílica autopolimerizável e polida quimicamente e sua influência na resistência transversa e na microdureza interna. Quatro grupos com amostras específicas para cada ensaio foram confeccionados com resina autopolimerizáve1 JET CLÁSSICO. Gl) as amostras foram submetidas ao polimento mecânico; G2) as amostras foram submetidas ao polimento químico com fluído para polimento POLI-QUIM; G3) após o polimento químico, as amostras foram submetidas a um ciclo complementar de polimerização no microondas de 450 W / 3 min e G4) após o polimento químico, as amostras receberam um ciclo complementar em água a 65°C / 1 h. As médias e desvios padrões da liberação de monômero na água no 1° dia em Ilg / cm2 foram: Gl=136,65:t 45,56 (a); G2=1315,70:t 225,50 (b); G3=848,21 :t 150,46 (c) e G4=295,18:t 81,67 (a). As médias e desvios padrões da resistência transversa em MPa foram: Gl=78,15 :t 6,11 (a); G2=65,15 :t 7,79 (b); G3=70,48 :t 2,96 (b) e G4=67,54 :t 8,05 (b). As médias e desvios padrões da microdureza interna (Knoop) foram: em 100 !lm - Gl=14,71 :t 1,07 (a); G2=12,79 :t 1,54 (a); G3=12,90:t 1,07 (a) e G4=11,69:t 2.51 (a); em 700 !lm - Gl=16,04:t 0,96 (a); G2=15,43 :t 0,69 (a); G3=15,31 :t 0,74 (a) e G4=18,07:t 0,53 (b); em 1500 !lm - Gl=16,21 :t 1,40 (a); G2=15,83 :t 0,70 (a); G3=15,56 :t 0,72 (a) e G4=18,85 :t 0,73 (b). A análise de variância e a comparação utilizando o teste de Tukey mostrou diferença entre os grupos e as médias seguidas por letras diferentes mostraram diferença significativa (a=5%). Diante desses resultados conclui-se que: o polimento químico aumentou o nível de monômero residual, diminuiu a resistência transversa das resinas e não alterou os valores de microdureza interna. As microondas e a água quente podem ser usados para reduzir os níveis de monômero residual no primeiro dia após a polimerização / Abstract: The monomeric methyl methacrylate can cause tissue damage. The aim of the present study was to investigate the effect of microwave heating and hot water on the residual monomer levei of an acrylic resin chemicaly activated and chemicaly polished and their effects on the transverse strength and internal microhardness. F our groups with specific patterns to each test were prepared using JET CLASSICO, an autopolimering resin. G 1) the specimens were mechanicalypolished; G2) the specimens were chemicaly polished using POLI-QUIM, a chemical polishing fluid; G3) after the chemical polishing, the specimens were submited to an aditional cicIe in the microwave oven irradiated at 450 Watts for 3 minutes; G4) after the chemical polishing, the specimens were submited to an aditional cicIe into water at 65°C for 1 hour. The means and standard deviations of residual monomer lost into water at the 1 st day were (flglcnf): Gl=136.65 :t 45.56 (a), G2=1315.70 :t 225.50 (b), G3=848.21 :t 150.46 (c) e G4=295.18:t 81.67 (a). The means and standard deviations oftransverse strength were (MPa): Gl=78.15.:t 6.11 (a), G2=65.15 :t 7.79 (b), G3=70.48 :t 2.96 (b) e G4=67.54 :t 8.05 (b). The means and standard deviations ofinternal microhardness were (Knoop): at 100 flm - Gl=14.71 :t 1.07 (a), G2=12.79 :t 1.54 (a), G3=12.90 :t 1.07 (a) e G4=11.69 :t 2.51 (a); at 700 flm Gl=16.04:t 0.96 (a), G2=15.43 :t 0.69 (a), G3=15.31 :t 0.74 (a) e G4=18.07:t 0.53 (b); ~t 1500 flm - Gl=16.21 :t 1.40 (a), G2=15.83 :t 0.70 (a), G3=15.56:t 0.72 (a) e G4=18.85 :t 0.73 (b). The results of anlysis of variance and the means comparison using Tukey test showed diference between the groups. The means folowed by diferent letters showed significant diference (a=5%). It was conclude that: quimical polishing increased the leveI of residual monomer; decreased the transverse strength of acrylics; did not change the values of internal microhardness; microwave and hot water can be used to reduce the levei of residual monomer at the 1st day / Mestrado / Protese / Mestre em Clínica Odontológica
182

Efeito do clareamento intracoronário sobre a resistência de união de pinos de fibra de vidro à dentina radicular

Silva, Iane Souza Nery January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:09:59Z (GMT). No. of bitstreams: 1 339547.pdf: 935632 bytes, checksum: 0c1932dbf4e0ef6b94fad38425d1a04e (MD5) Previous issue date: 2016 / Objetivo: avaliar o efeito do clareamento intracoronário e do tempo de espera pós-clareamento, com ou sem o uso da pasta de hidróxido de cálcio (Ca (OH)2), na resistência de união (RU) de pinos de fibra de vidro à dentina radicular. Metodologia: quarenta incisivos centrais bovinos foram submetidos ao tratamento endodôntico. Após a obturação dos canais, um tampão cervical com 2 mm de espessura foi confeccionado 2 mm abaixo da junção cemento-esmalte utilizando cimento de óxido de zinco/ sulfato de zinco (Citodur). Após 1 semana, os dentes foram distribuídos aleatoriamente em quatro grupos (n=10): G1 (grupo controle) ? sem clareamento, cimentação imediata do pino; G2 ? clareamento intracoronário e cimentação imediata do pino; G3 ? clareamento intracoronário, curativo temporário com Ca (OH)2 por 7 dias e, na sequência, cimentação do pino; G4 ? clareamento intracoronário, tempo de espera de 7 dias e, na sequência, cimentação do pino. Nos grupos G2, G3 E G4 o clareamento foi realizado com peróxido de hidrogênio a 35% na câmara pulpar por 45 min. No G3 as amostras tiveram a câmara pulpar preenchida com pasta de Ca(OH)2 . Em todos os grupos os pinos (Whitepost DC nº 3) foram cimentados com cimento resinoso dual (Relyx ARC). Após 24 h, as raízes foram seccionadas, transversalmente, em uma máquina de cortes (Isomet 1000). Foram obtidas duas secções de 1 mm de espessura para cada região (cervical, média e apical) do pino. As amostras foram submetidasao teste de push-out (0,5 mm/min, Instron 4444). As falhas após desunião foram avaliadas em esteromicroscópio. Os dados foram analisados pelos testes ANOVA e Tukey (a=5%). Resultados: não houve diferença estatisticamente significativa na RU (MPa) entre os grupos avaliados. No G1 o terço cervical apresentou RU significativamente maior do que o terço apical (p<0,05). A RU foi semelhante entre os grupos para cada região do pino/dentina (p=0,44). Os modos de falhas mais frequentes foram: adesiva entre cimento/dentina (50,84%) (G1); coesiva do pino (35,38%) (G2); coesiva do pino (40,90%) (G3) e adesiva mista (40,67%) (G4). Conclusão: a realização do clareamento intracoronário e o tempo de espera pós-clareamento para a cimentação do pino, com ou sem utilização do Ca(OH)2, não influenciaram a RU de pinos de fibra de vidro à dentina radicular.<br> / Abstract : Aim: to evaluate the effect of intracoronary bleaching and post-bleaching time with or without the use of calcium hydroxide paste (Ca(OH)2) on fiberglass posts bond strength (BS) to root dentin. Methodology: forty bovine central incisors were submitted to endodontic treatment. After canal filling, a cervical plug with 2 mm thickness was made 2 mm below the cementum-enamel junction using a zinc oxide / zinc sulfate cement (Citodur). One week later, the teeth were randomly divided into four groups (n=10): G1 (control group): no bleaching, and immediate fiberglass post cementation; G2: intracoronary bleaching and immediate post cementation; G3: intracoronary bleaching, temporary dressing with Ca(OH)2 for 7 days and post cementation; G4: intracoronary bleaching, standby time of 7 days and subsequently, post cementation. In groups G2, G3 and G4 bleaching was carried out with 35% hydrogen peroxide in the pulp chamber for 45 min. G3 samples had the pulp chamber filled with Ca(OH)2 paste. In all groups, the posts (White Post DC #3) were cemented with a dual resin cement (Relyx ARC). After 24 h the roots were transversely sectioned in a cutting machine (Isomet 1000). There were obtained two sections of 1mm thickness for each post region (cervical, middle and apical). The samples were submitted to push-out test (0.5 mm/min Instron 4444). After dislodgments, the failures were evaluated in stereomicroscope. Datawere analyzed by ANOVA and Tukey tests (a= 5%) Results: there was no statistically significant difference in the BS (MPa) between the groups. In G1, BS of the cervical third showed significantly higher means values than the apical third (p< 0.05). The BS results were similar among the groups for each of the post/dentin region (p = 0.44). The most frequent failures modes were adhesive cement/dentine (50.84%) (G1); cohesive at the post (35.38%) (G2); cohesive at the post (40.90%), (G3) and mixed adhesive (40.67%) (G4). Conclusions: intracoronary bleaching as well as the time past between bleaching and post cementation, with or without the use of Ca(OH)2, had no influence on fiberglass post BS to root dentin.
183

Influencia das ciclagens termica e mecanica na adesão a estrutura dentinaria

Castro, Ana Karina Barbieri Bedran de 22 April 2003 (has links)
Orientador: Luiz Andre Freire Pimenta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:19:30Z (GMT). No. of bitstreams: 1 Castro_AnaKarinaBarbieriBedrande_D.pdf: 2994466 bytes, checksum: 8ca8ac8d1c918c21d291e3870123c962 (MD5) Previous issue date: 2003 / Resumo: Uma vez estabelecida a integridade da união durante e logo após a polimerização da resina composta, o desenvolvimento da infiltração marginal pode ocorrer depois de algum tempo devido ao estresse químico, térmico e/ou mecânico na interface adesiva. Sendo assim, avaliações "in vitro" empregando ciclos térmicos e mecânicos possibilitariam a simulação de alguns desafios clínicos aos quais diferentes materiais restauradores e substrato dentinário seriam expostos. Este estudo "in vitro" teve como objetivo estabelecer a influência da ciclagem térmica e mecânica através de cinco metodologias de avaliação: 1- Microinfiltração marginal de restaurações de resina composta em cavidades classe II do tipo "slot" vertical, com margem em dentina, através da penetração de corante ; 2- Resistência da união entre o substrato dentinário e o material restaurador, por meio do teste de cisalhamento; 3- Resistência a microtração da margem cervical de restaurações de resina composta em cavidades classe II do tipo "slot" vertical, com margem em dentina; 4- Avaliação de nanoinfiltração de restaurações de resina composta em cavidades classe II do tipo "slot" vertical, com margem em dentina; e 5- Durabilidade da resistência a microtração da margem cervical de restaurações de resina composta em cavidades classe II do tipo "slot" vertical, com margem em dentina. De acordo com os estudos desenvolvidos, pode-se observar que para a avaliação da microinfiltração, utilizando azul de metileno, nenhum efeito da ciclagem térmica e ciclagem mecânica, bem como a associação de ambas, foi observado. Para avaliação da resistência ao cisalhamento, nenhum efeito dos diferentes tipos de estresses (térmico e mecânico) foi observado. No entanto, para as avaliações de nanoinfiltração e de microtração, a associação de ciclagem térmica e mecânica resultou em significante aumento na extensão de penetração de nitrato de prata e diminuição nos valores de resistência a microtração. Diminuição dos valores de adesão foi observada após um ano de estocagem, onde estas diferenças não foram relacionadas ao uso de ciclagem térmica e mecânica / Abstract: Once the bonding was achieved during and after composite resin polymerization, the development of marginal leakage can occur after a long period of time, due to chemical, thermal, and mechanical stresses. In this way, "in vitro" evaluations using thermal cycling and mechanicalload cycling would allow simulations of oral challenges, in which material and tooth substrate are exposed. This "in vitro" study aimed to established the influence of thermal and mechanical load cycling on five methodologies of evaluation: 1- Marginal microleakage of class 11 type box restored with composite resin, with cervical margin at dentin; 2- Bond strength between flat dentin substrate and restorative material, using shear bond strength test; 3- Microtensile bond strength of cervical margins of class 11 box type restored with composite resin, with margin in dentin; 4- Nanoleakage evaluation of class 11 composite resin restorations with cervical margin in dentin; and 5- Long term evaluation of the bond strength of cervical margins of class 11 box type restored with composite resin, with margin in dentin. According to the different studies performed distinctly, it was observed that for microleakage, using methylene blue, no effect of thermal cycling, mechanicalload cycling, and thermal and mechanical load cycling performed in the same specimen was related. For shear bond strength, no effect of thermal and mechanical load cycling performed alone or together was related. On the other hand, for nanoleakage and microtensile bond strength evaluations, a statistically significant effect on respectively, increase in length of penetration and decrease in bond strength was observed when thermal cycling and mechanicalload cycling were performed in the same specimen. Long term bond strength evaluation resulted in a significantly decrease in bond strength after 1 year, where the decrease was not related to the use of thermal and mechanicalload cycling / Doutorado / Dentística / Doutor em Clínica Odontológica
184

Resistencia a compressão e a tração diametral de dois cimentos de ionomero de vidro modificados por resina, em diferentes relações po/liquido e tempos de armazenagem

Aratani, Monica 27 February 2003 (has links)
Orientadores: Antonio Carlos Pereira, Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:12:04Z (GMT). No. of bitstreams: 1 Aratani_Monica_M.pdf: 2243796 bytes, checksum: 6fee16ed486115e3406caea830ad5c5b (MD5) Previous issue date: 2003 / Resumo: o objetivo deste trabalho foi avaliar as resistências à compressão e à tração diametral dos cimentos de ionômero de vidro modificados por resina Fuji 11 LC e Vitremer, nas relações póllíquido 1: 1, 1:2 e 1 :3, após armazenagem em água destilada a 37 °C por 1, 7 e 28 dias. Para cada material, relação póllíquido e tempo de armazenagem, foram confeccionados 10 corpos-de-prova com 4 mm de diâmetro por 6 mm de altura, em molde de silicone. Cada extremidade foi fotoativada por 40 segundos, e após a remoção do molde, os corpos-de-prova foram fotoativados lateralmente (perpendicular ao longo eixo) por mais 40 segundos e depois imersos em água. Os ensaios de resistência à compressão foram realizados à velocidade de 1 mm/min, e os de resistência à tração diametral, a 0,5 mm/min, em máquina de ensaios universal Instron. Os resultados, convertidos em Megapascal, e submetidos à Análise de Variância e ao teste de Tukey (p<0,05), mostraram que a resistência à compressão foi influenciada pela relação póllíquido, mas a armazenagem exerceu pouca influência. A resistência à tração diametral mostrou diferentes comportamentos dos materiais nas condições estudadas, em que o Vitremer foi afetado pela relação póllíquido, mas não pelo tempo de armazenagem, e o Fuji 11 LC sofreu a influência de ambos fatores / Abstract: The aim of this study was to evaluate the compressive and diametral tensile strength of resin-modified GIC Fuji 11 LC and Vitremer, in powder/liquid ratio 1:1, 1:2 and 1 :3, in different periods of storage in 37°C distilled water for 1, 7 and 28 days. For each material, p/I ratio and time of storage, 10 specimens were prepared, with 4 mm in diameter by 6 mm in height in silicon moulds. Each extremity was photoactivated for 40 seconds, and after remotion from the mouds, the specimens were photoactivated laterally (perpendicular to long axis) for 40 seconds and after, immersed in water. The compressive strength tests were performed at 1 mm/min cross-head speed of and diametral tensile strength tests, at 0.5 mm/min, in Universal Tests Machine Instron. The results, converted to Megapascal, were submitted to ANOVA and Tukey's Test (p<0.05), and showed that compressive strength was influenced by p/I ratio, but storage in distilled water didn't show a strong influence. About diametral tensile strength, the materials showed different behavior in the studied conditions, where Vitremer was affected by p/I ratio but not by time of storage, and Fuji 11 LC was influenced by both conditions / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
185

Painéis de partículas de bambu e casca de amendoim com adesivo à base de mamona /

Nasser, Silvia Marana. January 2016 (has links)
Orientador: Ivaldo de Domenico Valarelli / Banca: Alexandre Jorge Duarte Souza / Banca: Rosane Aparecida G. Battistelle / Resumo: Na atualidade, pesquisas com painéis a base de madeira e outros materiais lignocelulósicos, como o bambu, casca de amendoim, casca de arroz, bagaço de cana de açúcar, entre outros, ganharam espaços buscando aproveitamento para os resíduos agroindustriais. Seguindo essa iniciativa, este trabalho tem como objetivo, determinar as potencialidades dos painéis de partículas aglomeradas homogêneas, construídos com bambu (B), juntamente com partículas de casca de amendoim (A), para aplicação na indústria moveleira e de construção civil, comparando os resultados obtidos nesta pesquisa com outros autores. Para tanto, foram produzidos painéis com partículas aglomeradas em quatro traços onde, através da análise das propriedades físicas e mecânicas conforme a norma brasileira NBR 14810 - 2 (2013), determinou-se os valores de inchamento em espessura 24h, absorção de água 24h, umidade, densidade, resistência a flexão (MOR e MOE), tração perpendicular e arranchamento de parafusos (topo e face). A densidade alvo dos painéis foi de 850 kg/m considerados painéis de alta densidade. O adesivo utilizado foi a poliuretana bi componente a base de óleo de mamona, na proporção de uma parte de poliol para uma parte de pré polímero (12% da massa de partícula = 157,52g). Os resultados analisados, indicam que os traços contendo bambu e amendoim, apresentaram resultados satisfatórios quando comparados à norma, e em alguns casos, com índices bem superiores aos definidos na NBR 14810-2 (2013), e por trabalho... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Currently, research on wood-based panels and other lignocellulosic materials, such as bamboo, peanut hulls, rice hulls, sugar cane bagasse, among others, won spaces seeking to use the agroindustrial waste. Following this initiative, this study aims to determine the potential of panels of homogeneous agglomerated particles, built wich bamboo (B), along with peanut shell particles (A), for use in the furniture industry and construction, comparing results obtained in this study with other authors. For this purpose, were produced with particles agglomerated in four traces which by analyzing the physical and mechanical properties as the Brazilian NBR 14810-2 (2013), we determined the values of swelling in thickness 24h Water uptake 24h moisture, density, bending strengh (MOR and MOE), perpendicular traction and arrachamento screws (top and side). The target density of the panels was 850 kg/m considered high density panels. The adhesive used was a biocomponent polyurethane castor oil base in proportion to one part of polyol to a part of prepolymer (12% particle mass = 157,52g). The analyzed results indicate that the traces containing bamboo and peanuts showed satisfactory results when compared to standard, and in some cases, with much higher rates to those defined in NBR 14810-2 (2013), and works by authors with similar research. The results described herein, the material tested has good potential for the production of particle board, can be applied in dry conditions (Type P4) as the norm, with opportunity for future studies / Mestre
186

O estudo das propriedades elásticas de materiais compósitos : um tratamento matemático /

Pacheco, Tiago Levi January 2019 (has links)
Orientador: Renata Zotin Gomes de Oliveira / Resumo: Este trabalho concentra-se no estudo do comportamento elástico de materiais através da análise das matrizes de rigidez e flexibilidade de estruturas elementares. Baseado em conceitos da disciplina Resistência dos Materiais e nas propriedades elásticas dos materiais são apresentadas e demonstradas relações matemáticas que refletem as associações entre as tensões normais e de cisalhamento atuantes e as deformações e distorções decorrentes. Essas relações são ilustradas computacionalmente, através do software Geogebra. Transformações de coordenadas possibilitam a determinação de tensões em planos diferentes dos originais de forma analítica ou gráfica. Estes conceitos são aplicados a materiais compósitos ortotrópicos sujeitos a carregamento plano, configuração característica de uma lâmina de material compósito empregada em estruturas mais complexas, possibilitando a determinação das propriedades elásticas de uma lâmina em direções diferentes das chamadas direções principais, alinhadas ou ortogonais à direção das fibras. / Abstract: This essay focuses on the study of the elastic behavior of materials through the analysis of the stiffness and flexibility matrices of elementary structures. Based on the concepts of the Material Resistance discipline and the elastic properties of the materials, mathematical relationships are presented and demonstrated that reflect the associations between the acting normal and shear stresses and the resulting deformations and distortions. These relationships are computationally illustrated through Geogebra software. Coordinate transformations allow the determination of stresses in different planes of the originals in an analytical or graphical way. These concepts are applied to orthotropic composites subjected to flat loading, characteristic configuration of a composite material blade used in more complex structures, making it possible to determine the elastic properties of a blade in different directions of the so-called main directions, aligned or orthogonal to the direction of the fibers. / Mestre
187

Resistência à fratura de coroas metalocerâmicas implanto-suportadas cimentadas e parafusadas / Fracture resistance of metal-ceramic cement- and screw-retained implant-suport single crowns

Oliveira, José Luiz Góes de 30 March 2009 (has links)
Nas próteses sobre implante, a escolha do sistema de retenção (cimentada ou parafusada) muitas vezes está relacionada com a preferência pessoal de cada profissional. Porém alguns aspectos que diferem esses tipos de prótese devem ser levados em consideração no momento desta seleção. A passividade de assentamento, a reversibilidade, a estética, a oclusão e a presença do orifício de acesso ao parafuso. A ausência de orifícios de acesso ao parafuso é uma grande vantagem quando se utilizam próteses cimentadas principalmente quando se trata de casos onde a estética é uma prioridade. Além disto, a descontinuidade da cerâmica nas próteses parafusadas pode se apresentar como um fator de fragilização para a cerâmica. Isto se torna ainda mais grave quando o orifício de acesso ao parafuso constituído apenas por cerâmica com o objetivo de minimizar sua deficiência estética. É neste sentido que o presente trabalho se propõe a avaliar a resistência à fratura da cerâmica em próteses metalo-cerâmicas implantosuportadas cimentadas e parafusadas com dois diferentes desenhos de infraestruturas. Além disto, observar se a simulação de envelhecimento da cerâmica através da ciclagem mecânica influencia na sua resistência à fratura sob carga compressiva. Para isto, 10 coroas metalo-cerâmicas cimento-retidas (Grupo controle), 10 coroas metalo-cerâmicas parafusadas diretamente sobre o implante e orifício de acesso ao parafuso em metal medindo 2mm de altura (Próteses parafusadas com \"chaminé\") e 10 coroas metalo-cerâmicas parafusadas diretamente sobre o implante com orifício de acesso ao parafuso em porcelana medindo 2mm de altura (Próteses parafusadas sem \"chaminé\") foram confeccionadas de forma padronizadas. Metade dos corpos-de-prova de cada grupo (n=5) foram submetidas ao teste de ciclagem mecânica com auxílio de uma máquina eletro-mecânica de fadiga que continha um dispositivo de aço inoxidável com a ponta da forma esférica (6mm de diâmetro) que promovia uma carga simultânea em 4 vertentes triturantes (2 vestibulares e 2 linguais), simulando um contato com o dente antagonista por 1.200.000 ciclos, com uma freqüência de contato de 2Hz e carregamento de 100N, em água a uma temperatura de 37ºC. Todos os corpos-de-prova foram submetidos ao teste de compressão axial realizado em uma máquina de testes a uma velocidade de 0,5mm/min para que um dispositivo de extremidade arredondada(6mm de diâmetro) entrasse em contato com a coroa. Os valores médios da força requerida para a fratura dos corpos-de-prova foram calculados e comparados pela análise de variância a 2 critérios (1= tipo de infra-estrutura; 2= ciclagem prévia) e teste de Tukey. Pode-se concluir que a ciclagem mecânica não influenciou na resistência final dos corpos-de-prova quando submetidos à carga compressiva. Além disto, verificou-se que as próteses cimentadas apresentaram maior resistência à fratura da cerâmica que as duas variações de infra-estrutura para próteses parafusadas com níveis de significância estatística (p\' < OR =\'0,5). Entre as próteses parafusadas não foram observadas diferenças estatisticamente significantes (p\' > OR = \'0,5). / In implant prosthodontics, the choice of retention system (cemented or screwed) is often related to personal preferences of each professional. However, some aspects that differenciate these 2 types of prosthesis must be considered at the time of selection: the passivity of the fit, the reversibility, the aesthetics, the occlusion and the presence of the occlusal opening of the screw-access hole. The absence of access hole is a great advantage when using cemented prosthesis especially when it comes to cases where aesthetic is a priority. In addition, the discontinuing of the ceramic in the screwed prosthesis may be a factor of weakening. This becomes even more serious when the screw-access hole is totally ceramic in order to minimize its aesthetic deficiency. The aim of this study was to evaluate the resistance to fracture of cemented and screw-retained implant-supported metalloceramic crowns with two different frameworks designs. Moreover, the influence of the aging of ceramics by mechanical cycling on the resistance to fracture under compressive load was also observed. Ten cement-retained, ten screw-retained with the screw-access hole in metal measuring 2mm height (\"chimney\") and ten screw-retained with screw-access hole in ceramic measuring 2mm height (without \"chimney\") single crowns were manufactured. All screw-retained crowns were screwed directly over the implant. Half of the specimens from each group (n=5) were subjected to Mechanical cycling. The load (100N, 1.200.000 cycles, 2 Hz) was applied by a spherical stainless steel tip (6mm in diameter) simultaneously on 4 cusps (2 buccal and 2 lingual), simulating the contact with the antagonist tooth, under water at 37oC. All specimens were subjected to axial compression with a spherical tip (6mm in diameter) in a universal testing machine at 0.5mm/min. Mean values of maximum force required to fracture were analyzed using 2-way ANOVA (1=framework, 2=mechanical cycling) and Tukey\'s test for multiple comparisons (p\' < OR =\'0,5). Mechanical cycling did not affect the strength of the specimens when subjected to compressive load. Cemented prosthesis had greater resistance to fracture than the two variations of screwed frameworks with statistically significantdifferences. Between the 2 types of screwed prosthesis no statistically significant differences were observed.
188

Tratamento térmico pré e pós-cura de diferentes compósitos: análise térmica, reistência à flexão e grau de conversão / Heat treatment pre and post cured of differents composites: thermal analysis, flexural strength and degree of conversion

Gomes, Mauricio Neves 04 June 2008 (has links)
O objetivo deste estudo é realizar a caracterização térmica, resistência à flexão e o grau de conversão de um compósito nanoparticulado (Filtek Supreme XT: FT) e um microhíbrido (Esthet X: ET), cor A2, submetidos a diferentes tratamentos térmicos. Os grupos experimentais foram: G1: sem tratamento; G2: pré-aquecimento à 68°C com dispositivo Calset; G3: pós-aquecimento em forno MP-130, 10°C/min até 140°C e G4: pré e pós-aquecimento. Depois da fotoativação, foram realizadas análise termogravimétrica e calorimetria exploratória diferencial (DSC) para determinar a estabilidade térmica dos compósitos, temperatura de transição vítrea (Tg), pico de exotermia e calor liberado após fotoativação. O ensaio de resistência à flexão foi realizado 24h após armazenagem dos corpos de prova em água destilada a 37°C. A análise do grau de conversão foi realizada com espectrofotômetro FT-Raman. Análise de variância e teste de Tukey (p<0,05) demonstraram que os compósitos FT e ET têm 25,8% e 23,7% de matriz orgânica em peso respectivamente e estabilidade térmica até 200°C. O pico exotérmico do G2 (63,5°C) é maior do que G1 (60,9°C). Os grupos G3 e G4 não apresentaram pico exotérmico e calor liberado. A tg é de aproximadamente 160,5°C para o FT e de 161,4°C para o ET. A resistência à flexão (MPa) e grau de conversão(%) foram respectivamente: G1 (149,1; 60)=G2(152,5; 56,4) e G3 (170,5; 72,6)=G4 (178,2; 71,8) . O compósito ET apresenta maior grau de conversão que FT. À partir da caracterização térmica foi possível observar que o pré-aquecimento em condições não isotérmicas não promoveu maior conversão e resistência à flexão. O tratamento térmico deve ser realizado acima de 160°C. / The aim of this study was to perform the thermal characterization,flexural strength and degree of conversion of two composites, a nanofilled (Filtek Supreme XT: FT) and a microhybrid (Esthet X: ET), shade A2, submitted to different thermal treatments. Methods: The experimental groups were: G1: no treatment; G2: preheated at 68°C with Calset device; G3: post-heated in a MP-130 (EDG) oven, 10 °C/min up to reach 140°C for 20min and G4: pre and post-heated. After curing, thermogravimetric analysis and differential scanning calorimetry (DSC) were carried to determine thermal stability of the composites, glass transition temperature (Tg), exothermic peak and heat releasing after photoactivation. Three-point flexural test was performed after stored in water at 37oC for 24 hours. Degree of conversion was determined using a spectrophotometer FT-Raman. Analysis of variance and Tukey\'s test (P<0.05) showed that FT and ET composites have 25.8% and 23.7% of organic matrix in weight respectively and thermal stability at 200°C. The G2 group release more heat (9.9J/g) than G1 (7.3J/g). Exothermic peak of G2 group (63.5°C) is higher than G1 (60.9°C). G3 and G4 groups did not show exothermic peak and heat releasing. ET composite of G2 group presented the highest exothermic peak (65.2°C) of all groups. The Tg is nearly 160.5°C to FT and 161.4°C to ET. Flexural strength (MPa) and degree of conversion (%) were respectively: G1(149.1; 60) = G2(152.5; 56.4) and G3 (170.5; 72.6) = G4 (178,2; 71,8). ET composite presented higher conversion values than FT. Pre-heating at non-isothermal conditions does not promote higher conversion and flexural strength. Heat treatment after cure can be carried through 160°C.
189

Influencia del metacaolin en las propiedades en estado fresco del cemento Portland: hidratación y retracción química. / Influence of metakaolin in the fresh properties of Portland cement: hydration and chemical shrinkage.

Estrada Caceres, Delver Plinio 31 October 2016 (has links)
Actualmente los materiales cementicios suplementarios como el metacaolín, son comúnmente empleados en la industria cementera y de la construcción, debido a factores ambientales, económicos y técnicos. La mayoría de estudios que evalúan la influencia del metacaolín en sistemas cementicios, se enfocan en aspectos de desempeño y de resistencia mecánica, en edades avanzadas. Existen pocos estudios que evalúan la etapa inicial de hidratación. Por tanto, este trabajo tiene como propósito entender mejor la influencia que tiene la sustitución parcial de metacaolín en pastas de cemento Portland, durante las primeras 72 horas de hidratación. Normalmente para evaluar la cinética de hidratación se analiza el calor liberado, usando un calorímetro de conducción isotérmico. Sin embargo, otra técnica relativamente nueva usada en este estudio, es medir la retracción química en forma continua; en Brasil son raros los estudios que usen retracción química para obtener la cinética de hidratación. Para tal fin se elaboraron pastas utilizando reemplazos de metacaolín de 5, 10 y 20% en masa, además de una pasta de referencia, usando una relación constante agua/sólido de 0.5. La retracción química fue medida en forma continua automatizando el método de la dilatometría, también se evaluó la cinética de hidratación usando un calorímetro isotérmico. Adicionalmente, el desarrollo de los productos hidratados fue estudiado por análisis termogravimétrico y difracción de rayos X. Los resultados obtenidos muestran que existe una excelente relación entre la retracción química y la calorimetría y que la adición de metacaolín produce cambios en la cinética de hidratación, que también afectan a la retracción química. / Currently the supplementary cementitious materials such as metakaolin are commonly used in the cement and construction industry, due to environmental, economic and technical factors. Most studies evaluating the influence of metakaolin in cementitious systems focus on aspects of performance and mechanical strength at older ages. There are few studies evaluating the initial stage of hydration. Therefore, this paper aims to better understand the influence of the partial replacement of metakaolin in Portland cement pastes during the first 72 hours of hydration. Normally to evaluate the kinetics of hydration heat released is analyzed using an isothermal calorimeter. Nevertheless, another relatively new technique used in this study is to measure the chemical shrinkage continuously; in Brazil are rare studies using chemical shrinkage to obtain hydration kinetics. This study shows the influence of partial replacement of Portland cement by metakaolin in the hydration reactions and chemical shrinkage of cementitious pastes. For this, pastes were prepared using metakaolin replacements of 5, 10 and 20% by mass, and a reference paste, using a constant water/solid ratio of 0.5. Chemical shrinkage was measured continuously automating the method of dilatometry, hydration kinetics was evaluated using an isothermal conduction calorimetry. Additionally, the development of hydrated products was studied by thermogravimetric analysis and X-ray diffraction. The results show that there is an excellent relationship between chemical shrinkage and calorimetry and the addition of metakaolin leads to changes of the hydration kinetics, which also affect the chemical shrinkage.
190

Efeito da clorexidina na reidratação da dentina irradiada com laser Er:YAG após envelhecimento / Chlorhexidine effect on rehydration of irradiated dentin with Er:YAG laser after aging

Galafassi, Daniel 03 February 2012 (has links)
Esse estudo in vitro avaliou a resistência adesiva da dentina preparada com laser de Er:YAG ou broca, reidratada com clorexidina ou água deionizada, após armazenamento em saliva artificial e termociclagem. Cento e vinte terceiros molares humanos hígidos foram seccionados no terço médio da coroa, expondo a superfície dentinária (n=10). Os espécimes foram divididos aleatóriamente de acordo com o tratamento [laser de Er:YAG + reidratação com água deionizada (LW), laser de Er:YAG + reidratação com clorexidina a 2% (LC), turbina de alta-rotação com broca #245 + reidratação com água deionizada (TW) e turbina de alta-rotação com broca #245 + reidratação com clorexidina a 2% (TC)]. Após o preparo da dentina, os espécimes foram condicionados com ácido fosfórico 35%, lavados e secos com ar. A reidratação da dentina foi realizada através da aplicação de 1.5!L de água deionizada ou clorexidina 2%. Um sistema adesivo etch and rinse foi aplicado seguido da restauração com resina composta. Em cada grupo os espécimes foram sub-divididos de acordo com o envelhecimento [24 horas de armazenamento em saliva artificial / sem termociclagem (NA); 6 meses de armazenamento em saliva artificial / 12.000 ciclos térmicos (6A); 12 meses de armazenamento em saliva artificial / 24.000 ciclos térmicos(12A)]. Após cada período de envelhecimento, os dentes foram seccionados a fim de se obter 4 palitos com area de ±1.0 mm2, que foram submetidos ao teste de microtração usando uma máquina universal de testes com velocidade de 0.5 mm/min. Para a análise da interface adesiva em MEV foram utilizados 36 terceiros molares hígidos (n = 3) que foram restaurados e envelhecidos como descrito no protocolo empregado para o teste adesivo. ANOVA a dois critérios mostrou que não houve diferença significante para a interação entre os fatores e para o fator envelhecimento. O teste de Tukey 5% mostrou que o grupo LC apresentou os menores valores de resistência adesiva. A análise da interface adesiva através da MEV demonstrou que para os grupos irradiados houve formação de camada híbrida irregular com presença de fendas e o envelhecimento não interferiu na morfologia da interface adesiva. A reidratação com clorexidina influenciou negativamente a resistência adesiva do prepare com laser de Er:YAG. O envelhecimento em saliva artificial e termociclagem não interferiram na resistência adesiva da dentina. / This in vitro study evaluated the bond strength of dentin prepared with Er: YAG laser or turbine, rehydrated with chlorhexidine or deionized water after artificial saliva storage and thermocycling. One hundred twenty human third molars were sectioned in order to expose the dentin surface (n=10). The specimens were equally and randomly divided according to treatment [Er:YAG laser + deionized water rehydration (LW), Er:YAG laser + chlorhexidine 2% rehydration (LC), bur on high-speed turbine + deionized water rehydration (BW) and bur on high-speed turbine + chlorhexidine 2% rehydration (BC)]. After dentin preparation, the specimens were etched with 35% phosphoric acid, washed and dried with air. The dentin rehydration method was performed with deionized water or chlorhexidine 2% by applying 1.5!L of each solution. An etch and rinse adhesive system was then applied and the samples were restored with a composite. In each group, the specimens were sub-divided in accordance with the aging method [24 hours artificial saliva storage, no thermocycling (NA); 6 months of artificial saliva storage, 12.000 thermocycling (6A); 12 months of artificial saliva storage, 24.000 thermocycling (12 A)]. After each aging period, each tooth was sectioned in order to obtain 4 sticks with a cross-sectional area of 1.0 mm2, which were submitted to microtensile test using the Universal Test Machine (0.5 mm/min). For the adhesive interface analysis by SEM, 36 healthy third molars (n=3) were restored and aged as the protocol used for the adhesive test. The two-way ANOVA showed no significant differences for the interaction between the factors and for the aging factor. Tukey test 5% showed that the LC group had the lowest bond strength values. The adhesive interface analysis by SEM showed that the irradiated groups presented irregular hybrid layer and cracks and the aging did not affect the adhesive interface morphology. The rehydration with chlorhexidine negatively influenced the bond strength of the preparation with the Er:YAG laser. The artificial saliva aging and thermocycling did not interfere with dentin bond strength.

Page generated in 0.4464 seconds