• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 2
  • Tagged with
  • 27
  • 14
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da extrusão bacteriana apical após instrumentação mecanizada com sistemas reciprocantes de instrumento único comparados a um sistema rotatório multi-instrumento / Apical extrusion of bacteria by reciprocating single file systems and rotary multi-file system

Justine Monteiro Monnerat Tinoco 27 September 2013 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo deste estudo foi avaliar ex vivo a extrusão bacteriana apical após instrumentação mecanizada com sistemas reciprocantes de instrumento único e movimento reciprocante (WaveOne and Reciproc) comparados a um sistema multi-instrumentos (BioRaCe). Quarenta e cinco incisivos inferiores humanos unirradiculares, ovais e de anatomia semelhante foram utilizados. Os dentes foram acessados e seus canais radiculares foram contaminados com uma suspensão de Enterococcus faecalis e incubados por 30 dias possibilitando crescimento bacteriano em biofilme. Os dentes contaminados foram divididos em três grupos com 15 espécimes cada (RE - Reciproc, WO -WaveOne e BR - BioRaCe). Foram utilizados oito dentes para grupos controle de crescimento bacteriano positivo e negativo. As bactérias extruídas apicalmente durante a instrumentação foram coletadas em frascos de vidro contendo 0,9% de NaCl. As amostras microbiológicas foram retiradas dos frascos e incubadas em meio BHI ágar, durante 24 horas. O crescimento bacteriano foi contado e os resultados foram expressos em unidades formadoras de colônia (UFC). Os dados foram analisados pelos testes estatísticos de Wilcoxon e Kruskal-Wallis. Não houve diferença estatisticamente significante no número de UFC entre os dois sistemas reciprocantes (p>0,05). Em contrapartida, o sistema de instrumentos rotatórios mostrou uma quantidade de UFC significativamente maior do que os dois outros grupos (p <0,05). A partir da análise dos resultados e dentro das limitações deste estudo foi possível concluir que todos os sistemas de instrumentação testados extruem bactérias apicalmente. No entanto, ambos os sistemas de instrumento único e movimento reciprocante extruem menos bactérias apicalmente do que o sistema rotatório multi-instrumentos de referência. / The aim of this work was to evaluate ex vivo the apical bacterial extrusion of reciprocating single-file systems (Wave One and Reciproc) compared to a multi-file rotary system (BioRaCe). This was tested in the current study using extracted, single-rooted teeth with oval canals (n = 45) with similar anatomy. Endodontic access cavities were prepared and root canals were contaminated with an Enterococcus faecalis suspension and incubated for thirty days to promote bacterial biofilm growth. The contaminated teeth were divided into three groups with 15 specimens each (RE - Reciproc, WO- Wave One and BR - BioRaCe). Positive and negative bacterial growth control groups were done. Bacterial extruded from the apical foramen during instrumentation were collected into vials containing 0.9% NaCl. The microbiological samples were taken from the vials and incubated in BHI agar medium during 24h. Bacterial growth was counted and the results were given by colony-forming units (CFU). These data were analyzed by Wilcoxon matched-pairs signed rank test and KruskalWallis H-test. After data analysis, no significant difference was found in the number of CFU between the two reciprocating systems (p > 0.05). Conventional multi-file rotary system group showed significantly higher CFU than both of the other two reciprocating groups (p<0.05). Based on the results evaluation and within the limitation of this study, it was possible to conclude that all tested instrumentation systems extruded bacteria beyond the apex. However, both reciprocation single-file systems apically extruded fewer bacteria than the conventional multi-file rotary system.
12

Eletrodeposição de revestimentos funcionais compósitos Cu/partículas de óxidos de alumínio / Electrodeposition of functional composite coatings Cu/partículas de óxidos de alumínio

Thaís Guimarães de Lima 14 March 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Revestimentos funcionais compósitos são um atrativo tecnológico crescente, pois possibilitam a combinação de materiais metálicos, poliméricos ou cerâmicos, resultando em propriedades superiores as dos materiais individuais, sendo por este motivo, largamente aplicados na engenharia de materiais. Na presente dissertação, foram produzidos revestimentos compósitos por eletrodeposição através da codeposição de uma matriz metálica de cobre e de partículas de óxidos de alumínio incorporadas (g - Al2O3 ou AlO(OH)), sobre substratos de aço carbono, a partir de diferentes banhos eletrolíticos. Três etapas foram efetuadas, na primeira realizou-se o estudo da influência do modo de agitação e da presença ou não de ligantes (citrato de sódio 1,00 mol/L) nos teores de cobre e alumina nos revestimentos produzidos. Em seguida foi avaliada a ação de complexantes (citrato de sódio 1,00 mol/L e pirofosfato de potássio 0,90 mol/L) usando polarização potenciodinâmica e voltametria cíclica, em conjunto com microbalança eletroquímica de cristal de quartzo (EQCM) e a posterior produção de revestimentos compósitos a partir de banhos contendo CuSO4 0,02 mol/L + pirofosfato de potássio 0,90 mol/L + 20 g/L de alumina, variando a densidade de corrente aplicada (I), a velocidade de agitação do eletrodo rotatório (A) e o do tempo de agitação prévia (t). Por fim, na terceira etapa, fez-se a substituição de alumina por Boehmita e a produção dos revestimentos a partir de banhos contendo CuSO4 0,02 mol/L + pirofosfato de potássio 0,90 mol/L + 20 g/L de Boehmita, empregando um planejamento composto central, em que os parâmetros citados também foram variados. Os resultados mostraram que a presença de um ligante e a agitação prévia e continuada do eletrólito durante o experimento foram fundamentais para a produção dos revestimentos compósitos. Ensaios de EQCM mostraram que o citrato se adsorveu na superfície do eletrodo de ouro, diferentemente do pirofosfato. Os teores de Boehmita e cobre nos revestimentos produzidos, assim como a morfologia, resistência de polarização e densidade de corrente de corrosão dos revestimentos foram influenciados pelos parâmetros avaliados. / Functional coatings composites are an increasing technologic attractive, as they allow the combination of metallic, polymeric or ceramic materials resulting in properties superior than those of the individual materials. They are, therefore, widely used in engineering materials. In this dissertation, composite coatings were produced by electrodeposition through co-deposition of a copper metal matrix and particulate aluminum oxides embedded (g - Al2O3 or AlO (OH)) on carbon steel substrates from different electrolytic baths. Three steps were taken: first the influence of the stirring mode and the presence or absence of ligands (sodium citrate 1.00 mol/L) in the amount of copper and alumina in the produced coatings were studied. After it, was evaluated the action of complexing agents (Sodium citrate 1.00 mol/L and potassium pyrophosphate 0.90 mol/L) using potentiodynamic polarization and cyclic voltammetry together with electrochemical microbalance quartz crystal (EQCM), and further producing composite coatings from baths containing CuSO4 0.02 mol/L potassium pyrophosphate + 0.90 mol/L + 20 g/L of alumina, varying the applied current density (I), the stirring speed of the rotating electrode (A) and the stirring time prior to electrodeposition (t). Finally in the last step was performed the substitution of alumina by bohemite and production of coatings from baths containing CuSO4 0.02 mol/L potassium pyrophosphate + 0.90 mol/L + 20 g/L bohemite, employing a central composite design, in which these parameters were also varied. The results showed that the presence of a ligand and the electrolyte stirring prior and during the experiment were critical to the production of composite coatings. EQCM tests showed that the citrate is adsorbed on the surface of the gold electrode, unlike pyrophosphate. The results showed that the contents of boehmite and copper in the coatings produced, as well as the morphology, polarization resistance and corrosion current density of the coatings were influenced by the evaluated parameters
13

Estudo da fluidodinâmica e da secagem de um secador rotatório da indústria de fertilizantes

Fernandes, Nilson José 18 January 2008 (has links)
The dimensioning, the modeling and the simulation of the rotary dryers constitutes a big challenge. The drying involves mass and heat transfer, and fluid dynamics processes of the most different forms. Great part of the dryers projects are done according to empiricism and based on the experience of engineers and on the scale-up of prototypes. The purpose of this piece of work was: to analyze the equations, the models and the project proposals on drying found in the literature about rotary dryers, using for this analysis experimental dada obtained by drying granulated fertilizers GTSP in a conventional industrial cocurrent rotary dryer (3m in diameter x 30m in length). Having collected the operational data (variables of the process) and obtained the results, it is carried out an analysis of the project proposals of the rotary dryers and of the drying models evaluated according to other pieces of work of the same kind (ARRUDA, 2008 and CRISTO, 2004). Besides it is also identified the prediction parameters of residence time, the coefficient of heat transfer and others fluid dynamics information. In the presence of the fact that experimental tests were accomplished in an industrial equipment, there were limitations regarding the parameter variation. The equipment dimensions are fixed (industrial unit) and other parameters are variables that guarantee the quality and the productivity of the industrial unity. Hence, the equipment rotation is a parameter able to be analyzed once there is, exceptionally in the equipment in which the tests were accomplished, a rotation control that enables, according to the structural limitations of the equipment, a variation of 20% of its nominal rotation. The tests were accomplished using dryer rotations of 3.5 and 4.2 rpm. The results which were obtained according to the behavior of the fluid dynamics of the material in the interior of the dryer, presented good concurrence with the models shown in the literature. To determine the flight holdup distribution and the behavior of the material cascading in the inner part of the dryer (time, height and average angle of the fall), the methodology REVOL et al. (2001) presented quite consistent information concerning the prediction, using the friction coefficient determined experimentally of 0.746 for the GTSP. In order to determine the residence time, the equation that fitted best to the experimental results was FRIEDMAN and MARSHALL S (1949) Equation with parameters estimated by ARRUDA (2008). The results that were obtained for the mass balance and energy were quite consistent and they made clear a quite pertinent situation related to the project considerations that deal with the premises of false air entrances. In order to determine the global coefficients of heat transfer, the equation that best foresaw this parameter is the one presented by MILLER et al. (1942), pondering the reduction of the temperature of the gases in the beginning of the dryer which was caused by the false air entrances. The modeling proposed by ARRRUDA (2008) presented significative deflections according to the experimental results. They were possibly caused by imprecision while measuring, by premises of false air entrances (loses) and/or by possible differences related to the behavior of the materials used in ARRUDA S tests (2008) and the ones used in the experiments. The application of the Methodology I (VAN T LAND, 1991) presented inconsistencies in the project opposing the approach of false air entrances mentioned before. The Methodology II (NONHEBEL and MOSS, 1971) does not presume the knowledge of the drying curve of the material. Thus, the results obtained in ARRUDA (2008) were used. As it happened to Methodology I, inconsistencies in the project were found. However, the profiles of the coefficients of mass and heat transfer traced with the results that were obtained in ARRUDA (2008) presented a kind of behavior with physically expected tendencies. / O dimensionamento, modelagem e simulação de secadores rotatórios constituem em um grande desafio. A secagem envolve transferências de calor e massa, e processos fluidodinâmicos das mais diferentes formas. A maior parte dos projetos de secadores é feita por empirismo, com base na experiência de engenheiros e scale-up de protótipos. O objetivo do trabalho foi analisar os equacionamentos, modelagens e propostas de projetos de secagem encontrados na literatura para secadores rotatórios utilizando-se para esta análise dados experimentais obtidos com a secagem de fertilizantes granulados (GTSP) em um secador rotatório concorrente industrial convencional (3 m de diâmetro x 30 m de comprimento). Com os dados operacionais coletados (variáveis de processo) e os resultados obtidos, é feita uma análise das propostas de projetos de secadores rotatórios e modelagens de secagem avaliadas em outros trabalhos desta mesma natureza (ARRUDA, 2008 e CRISTO, 2004), além de identificar parâmetros de predição de tempo de residência, coeficientes de trocas térmicas e informações fluidodinâmicas. Diante o fato dos testes experimentais serem realizados num equipamento industrial, houve limitações quanto a variação de parâmetros. As dimensões do equipamento são fixas (unidade industrial) e outros parâmetros são variáveis que garantem a qualidade e produtividade da unidade industrial, ficando, portanto, a rotação do equipamento como um parâmetro possível de ser analisado, uma vez que excepcionalmente no equipamento onde foram realizados os testes, há um inversor de freqüência que possibilita, dentro das limitações estruturais do equipamento, uma variação de 20 % da rotação nominal do mesmo. Os testes foram realizados com rotações do secador de 3,5 e 4,2 rpm. Os resultados obtidos quanto ao comportamento fluidodinâmico do material no interior do secador apresentaram boa concordância com as modelagens apresentadas na literatura. Para a determinação da distribuição de carga nos suspensores e o comportamento do cascateamento de material no interior do secador (tempo, altura e ângulo médio de queda) a metodologia REVOL et al. (2001) apresentou informações bastante consistentes de predição com a utilização do coeficiente de fricção determinado experimentalmente de 0,746 para o GTSP. Na determinação do tempo de residência a equação que melhor se ajustou aos resultados experimentais é a equação de FRIEDMAN e MARSHALL (1949) com parâmetros estimados por ARRUDA (2008). Os resultados obtidos para os balanços de massa e energia foram bastante consistentes e evidenciaram uma situação bastante pertinente em considerações de projeto que trata-se das premissas de entradas de ar falso. Na determinação dos coeficientes globais de transferência de energia, ponderando-se a redução de temperatura dos gases no início do secador provocada pelas entradas de ar falso, a equação que melhor previu este parâmetro é a apresentada por MILLER et al. (1942). A modelagem proposta por ARRUDA (2008) apresentou desvios significativos com os resultados experimentais; possivelmente provocados por imprecisões de medidas, premissas de ar falso (perdas) e/ou possíveis diferenças no comportamento dos materiais utilizados nos ensaios de ARRUDA (2008) e os utilizados nos experimentos. A aplicação da Metodologia I (VAN T LAND, 1991) apresentou inconsistências de projeto em contraponto à abordagem de entradas de ar falso citada anteriormente. A metodologia II (NONHEBEL e MOSS, 1971) não presume o conhecimento da curva de secagem do material. Utilizou-se, portanto, resultados obtidos em ARRUDA (2008). Da mesma maneira que para a Metodologia I verifica-se inconsistências de projeto, no entanto, os perfis dos coeficientes de transferência de calor e massa traçados com os resultados obtidos em ARRUDA (2008) apresentam comportamento com tendências esperadas fisicamente. / Mestre em Engenharia Química
14

Estudos fluidodinâmicos e de secagem de fertilizantes em secadores rotatórios concorrentes

Silvério, Beatriz Cristina 26 February 2010 (has links)
Universidade Federal de Goiás - Goiânia / Drying is an important process that a lot of products were submitted. However, this process is usually very energy-intense and has a large commercial impact on the cost of the final product. The conventional direct rotary dryer consists of equipment widely used in industrial area due to advantages such as, a high processing capacity of a wide variety of materials. This dryer is commonly used to dry and process granular materials, and has application across a wide range of industries like the fertilizer industry. The dryer consists of a rotating cylindrical shell rotated about its axis at a constant speed and slightly inclined to the horizontal. This type of equipment is characterized by the high consumption of energy required to heat the drying air at high temperatures. This work aims to study the aspects of fluid dynamics and fertilizer drying of super-phosphate fertilizer in concurrent direct rotary dryers and compare the performance of the same for other configurations that have been studied by the research group of systems particulated at FEQUI / UFU. The results of this study have values of loading, residence time, drying rate, and the difference between concurrent and countercurrent rotary dryers, working under the same operating conditions, enabling the evaluation of new versions of rotary dryers because of detailed study of conventional configurations. This study also describe a mathematic model to predict the air and solid temperature profiles and the solid moisture profile in a concurrent rotary dryer and compared the simulation results with the experimental data. / A secagem consiste em uma importante operação na qual se submetem diversos produtos industrializados. Porém, este processo é concebido como uma operação unitária que demanda uma intensa quantidade de energia o que implica em um grande impacto comercial no custo do produto final. O secador rotatório convencional de contato direto consiste em um equipamento amplamente difundido na área industrial por apresentar vantagens como, por exemplo, alta capacidade de processamento de uma grande variedade de materiais. Este tipo de secador é destinado principalmente para secagem de materiais granulados de escoamento livre, sendo vastamente empregado na indústria de fertilizantes. O secador rotatório consiste de um casco cilíndrico levemente inclinado em relação à horizontal, que gira em baixa velocidade em torno do próprio eixo. Esse tipo de equipamento é caracterizado pelo alto consumo energético necessário para aquecer o ar de secagem a elevadas temperaturas. O presente trabalho tem como objetivo estudar os aspectos fluidodinâmicos e de secagem do fertilizante super-fosfato simples granulado em secadores rotatórios convencionais com fluxo de ar concorrente e aquecimento direto, bem como comparar o desempenho do mesmo em relação a outras configurações já estudadas anteriormente pelo grupo de pesquisa em sistemas particulados da FEQUI/UFU. Como resultados deste trabalho foram obtidos valores de carregamento, tempo de residência, taxa de secagem, além da quantificação da diferença entre as configurações concorrente e contracorrente do secador rotatório, operando nas mesmas condições operacionais, viabilizando a avaliação de novas versões de secadores rotatórios a partir do estudo detalhado das configurações convencionais operando nas condições ótimas. Além dos estudos experimentais, também foi possível realizar a modelagem matemática do secador concorrente, a fim de se obter a predição dos perfis de umidade e temperatura do ar e do sólido, sendo os resultados da simulação comparados com os dados obtidos experimentalmente para a secagem de fertilizante. / Mestre em Engenharia Química
15

Avaliação por meio da microscopia eletrônica de varredura da limpeza e deformação de instrumentos rotários após a instrumentação de canais radiculares / Evaluation by scanning electron microscopy of cleaning and deformation of rotary instruments after use

Elaine Cristina Consolmagno 21 November 2011 (has links)
O presente estudo teve como objetivo avaliar, por meio da microscopia eletrônica de varredura (M.E.V.), a remoção de detritos e deformação superficial sofrida pelos sistemas endodônticos rotatórios de NiTi BioRace (BR); Protaper (PT) e Twisted File (TF) após cada uso, totalizando cinco usos, simulando as condições clínicas. Um total de 75 molares superiores humanos extraídos cuja raiz disto-vestibular apresentava curvatura de 0 a 5° e mésio-vestibular entre 20 e 30° de acordo com o método de Weine, foram selecionados e divididos em três grupos com 25 espécimes. Para o grupo I: realizou-se instrumentação com o sistema BR; para o grupo II com o sistema PT e para o grupo III, com o TF. Foram utilizadas cinco caixas de cada sistema rotatório para instrumentar os canais mesio e distovestibulares. Inicialmente os instrumentos foram fotografados em M.E.V. com aumento de 35 vezes, utilizados uma vez e em seguida passaram por um protocolo de limpeza baseado no proposto por Parashos, Linsuwanont e Messer (2004) previamente a esterilização e, em seguida eram analisados em M.E.V., antes do uso seguinte. Esses procedimentos foram realizados até o último uso. Os dados de limpeza foram submetidos ao teste estatístico de Kruskal Wallis para comparação global e ao teste de Dunn para comparação individual dos grupos, enquanto para análise da deformação foram submetidos ao teste estatístico do Qui-quadrado para comparação global e ao teste exato de Fisher para as comparações individuais, todos com significância de 5%. Os resultados apontaram diferenças estatisticamente significantes quanto à limpeza para o sistema BR com maior quantidade de detritos remanescentes do processo de fabricação em relação ao PT e TF; após os 5 usos, os sistemas BR e PT apresentavam-se mais limpos em relação ao início do experimento, enquanto o TF permaneceu com quantidade semelhante de detritos superficiais. Ocorreu deformação em 40% do sistema BR, sendo 5% fratura e, 100% do TF, sendo 40% fratura. O sistema PT não sofreu danos consideráveis de acordo com os critérios avaliados. Por meio dos resultados obtidos neste estudo, concluiu-se que o protocolo de limpeza utilizado não proporcionou superfícies completamente limpas tanto no decorrer quanto ao final do experimento e quanto a deformação superficial, o sistema TF apresentou o pior resultado, seguido do BR, enquanto o PT que não apresentou qualquer deformação quanto aos critérios avaliados. / The aim of this study was to evaluate by scanning electron microscopy (SEM) the debris removal and deformation surface by rotary NiTi endodontic systems BioRace (BR), Protaper (PT) and Twisted File (TF) before each use, total five uses, simulating clinical conditions. A total of 75 extracted human molars whose disto-vestibular roots had curvature between 0 and 5 degrees and mesio-vestibular roots had curvature between 20 and 30 degrees according to the Weine method were selected and divided into three groups of 25 specimens. In the Group I: was used the BR system, group II was used the PT system and group III was used the TF system to shaping the mesio and distovestibular molars canals. Were used a total of five boxes to each rotary system. Initially, the instruments were examined by SEM at a magnification of 35x, then used into root canals and submitted through the cleaning protocol based on proposed by Parashos, Linsuwanont and Messer (2004) prior to sterilization for further examination by SEM, before the next use. These procedures were carried out until the last use. The cleaning data were analysed using statistical Kruskal Wallis test for global comparison and the Dunn test for individual groups comparison. The deformation data were analysed using Chi-square test for overall comparison and Fisher exact test for individual comparisons, both with 5% significance. The results showed the following statistically significant differences regarding cleaning to BR system with highest amount of debris remaining from the manufacturing process in relation to the PT and TF; after the five uses, the BR and PT systems were cleaner in relation to the initial experiment, but the TF system had the same debris amount. The deformation occurred in 40% of the BR system, with 5% fractured and 100% of the TF, with 40% fractured. The PT system has not suffered considerable damage in accordance with the criteria evaluated. The results of this study showed that the protocol did not provide cleaning surfaces completely free of debris, especially in the TF system, while for the BR and PT, resulting in cleaner surfaces at the end of the experiment compared with the dirt initial (immediately removed from their packaging). The surface deformation of TF system presented the worst results, followed by the BR and PT did not show any deformation on the criteria evaluated.
16

Obtenção de catalisadores com estrutura Core–Shell para aplicação na reação de redução de oxigênio

Silva, Rudyere Nascimento 14 October 2016 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-03-07T12:13:32Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rudyere N. Silva.pdf: 2210655 bytes, checksum: 9a6bb45b8f0787da19c027da2a262132 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-03-07T12:13:50Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rudyere N. Silva.pdf: 2210655 bytes, checksum: 9a6bb45b8f0787da19c027da2a262132 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-03-07T12:14:08Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rudyere N. Silva.pdf: 2210655 bytes, checksum: 9a6bb45b8f0787da19c027da2a262132 (MD5) / Made available in DSpace on 2017-03-07T12:14:08Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rudyere N. Silva.pdf: 2210655 bytes, checksum: 9a6bb45b8f0787da19c027da2a262132 (MD5) Previous issue date: 2016-10-14 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / Recently, Pt-based catalysts with core-shell structure have been shown to be an alternative promising in the catalysis of the oxygen reduction reaction (RRO), providing a significant reduction of this noble metal in its composition. This work had as objective the obtaining of electrocatalysts with this type of structure to investigate its activities in front of the RRO. The synthesis method employed was sequential chemical reduction, in which nanoparticles of less noble metals were first obtained by the reduction of their precursors with NaBH4. These nanoparticles acted as nuclei for further Pt coating by reducing with ascorbic acid. The catalysts chosen for the synthesis were SnO2@Pt/C, Ni@Pt/C and NiSn@Pt/C. X-ray diffraction and cyclic voltammetry revealed evidence that core-shell structures were obtained in the synthesis of these electrocatalysts. The rotating disk electrode analyzes, in turn, showed that the highest activity for O2 reduction was attributed to the NiSn@Pt/C catalyst, even exceeding in about 82% the activity of the commercial Pt/C catalyst (E-TEK). However, Ni@Pt/C was the catalyst of lower activity among the electrocatalysts. Considering the RRO activity in the presence of methanol, the catalysts with core-shell structure synthesized presented higher tolerance to alcohol, especially in low overpotential values. The NiSn@Pt/C catalyst continued to exhibit the highest activity for the RRO, this time in the presence of methanol. It was shown to be broadly superior to Pt/C, to the other core-shell and Pt/C (E-TEK) catalysts, with activity in the presence of methanol four times higher than the commercial catalyst. / Recentemente, catalisadores à base de Pt com estrutura do tipo core-shell demonstraram-se como alternativas promissoras na catálise da reação de redução de oxigênio (RRO) ao mesmo tempo que proporcionaram redução significativa deste metal nobre em sua composição. Este trabalho teve como objetivo a obtenção de catalisadores com este tipo de estrutura para então investigar suas atividades frente à RRO. O método de síntese empregado foi a redução química sequencial, na qual primeiramente obteve-se nanopartículas de metais menos nobres através da redução de seus precursores com NaBH4. Estas nanopartículas atuaram como núcleos para um posterior recobrimento de Pt pela redução de seu precursor através da utilização de ácido ascórbico. Os catalisadores escolhidos para a síntese foram SnO2@Pt/C, Ni@Pt/C e NiSn@Pt/C. As análises de difração de raios-X e voltametria cíclica revelaram indícios de que estruturas do tipo core-shell foram obtidas na síntese destes catalisadores. As análises de eletrodo de disco rotatório, por sua vez, mostraram que a maior atividade para a redução de O2 foi atribuída ao catalisador de NiSn@Pt/C, ultrapassando, inclusive, cerca de 82% a atividade apresentada pelo catalisador comercial Pt/C (E-TEK). Entretanto, Ni@Pt/C apresentou-se como o catalisador de menor atividade dentre os estudados. Considerando a atividade frente à RRO na presença de metanol, os catalisadores com estrutura core-shell sintetizados apresentaram maior tolerância ao álcool principalmente em baixos valores de sobrepotenciais. O catalisador de NiSn@Pt/C continuou a exibir a maior atividade para a RRO, desta vez na presença de metanol. O mesmo demonstrou-se amplamente superior à Pt/C, aos demais catalisadores core-shell e à Pt/C (E-TEK), apresentando atividade na presença de metanol quatro vezes maior que o catalisador comercial.
17

Comparison of mechanical behavior between conventional NiTi, CM, M-Wire and CM-EDM alloy instruments for cyclic fatigue and torsion fracture - evaluation of fracture surface in scanning electron microscope / Comparação do comportamento mecânico entre instrumentos de liga NiTi convencional, CM, M-Wire e CM-EDM quanto a fratura por fadiga cíclica e por torção avaliação da superfície da fratura em microscópio eletrônico de varredura

Furlan, Renan Diego 31 July 2018 (has links)
The aim of this study was to evaluate the cyclic and torsional fatigue resistance of Nickel-Titanium rotary instruments manufactured by different thermal treatments. Were tested a total of 140 rotary instruments (n=20): Genius (GN size 25, .04 taper), Trushape (TS size 25, .06 taper), Logic (LOG size 25, .06 taper), Vortex Blue (VB size 25, .06 taper), ProTaper Gold (PTG size 25, .08 taper), Hyflex CM (HCM size 25, .06 taper) and Hyflex EDM (EDM size 25, .08 taper). Cyclic fatigue resistance testing was performed using an artificial stainless steel canal with a curvature (60° angle and 5- mm radius) located at 5 mm from the tip. The files (n=10) rotated until fracture and time was recorded in seconds. The torsional test evaluated the angular deflection and torque at failure of the instruments (n=10) at 3 mm from the tip according to ISO 3630- 1. The fractured surface of five instruments of each brand was observed by using scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. The cyclic fatigue resistance value of EDM size 25, .08 taper was significantly higher than those of all instruments tested (P<0.05). The LOG size 25, .06 taper showed a higher cyclic fatigue resistance than those of GN size 25, .04 taper; TS size 25, .06 taper (P<0.05). There was no difference among the others groups. The torsional test showed that PTG size 25, .08 taper had the highest torsional strength value of all instruments tested followed by VB size 25, .06 taper and EDM size 25, .06 taper (P<0.05). The LOG size 25, .06 taper showed significant difference only with GN size 25, .04 taper (P<0.05). No difference was found among the others groups (P>0.05). In relation to angular deflection, the GN size 25, .04 taper; TS size 25, .06 taper; HCM size 25, .06 taper, and EDM size 25, .08 taper showed significantly higher values until fracture than the others groups (P<0.05). No difference was found among PTG size 25, .08 taper, LOG size 25, .06 taper, and VB size 25, .06 taper (P<0.05). The EDM size 25, .08 taper presented the highest cyclic fatigue resistance among all the tested instruments. For the torsional test, the PTG size 25, .08 taper showed highest torsional strength and lowest angular deflection values. / O objetivo deste estudo foi avaliar a resistência às fadigas cíclica e torsional de instrumentos rotatórios de Níquel - Titânio fabricados por diferentes tratamentos térmicos. Foram testados o total de 140 instrumentos (n=20): Genius (GN diâmetro 25, conicidade .04), Trushape (TS diâmetro 25, conicidade .06), Logic (LOG diâmetro 25, conicidade .06), Vortex Blue (VB diâmetro 25, conicidade .06), ProTaper Gold (PTG diâmetro 25, conicidade .08), Hyflex CM (HCM diâmetro 25, conicidade .06) e Hyflex EDM (EDM diâmetro 25, conicidade .08). O teste de resistência à fadiga cíclica foi realizado utilizando um canal artificial de aço inoxidável com curvatura (ângulo de 60° e raio de 5mm) localizada a 5 mm da ponta. Os instrumentos (n=10) foram rotacionados até a fratura e tempo foi registrado em segundos. O teste torsional avaliou a deflexão angular e torque até a falha dos instrumentos (n=10) a 3 mm da ponta de acordo com a ISO 3630-1. A superfície da fratura de 5 instrumentos de cada fabricante foi observado utilizando o microscópio eletrônico de varredura (MEV). A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. O valor de resistência a fadiga cíclica do EDM diâmetro 25, conicidade .08 foi significantemente maior que todos os instrumentos testados (P<0.05). A LOG diâmetro 25, conicidade .06 mostrou maior resistência à fadiga cíclica que o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06 (P<0.05). Não houve diferença significante entre os outros grupos. O teste torsional mostrou que PTG diâmetro 25, conicidade .08 obteve o maior valor de torque até a fratura de todos os instrumentos testados seguido por VB diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .06 (P<0.05). O LOG diâmetro 25, conicidade .06 mostrou diferença significativa apenas com com GN diâmetro 25, conicidade .04 (P<0.05). Não houve diferença significativa entre os outros grupos (P>0.05). Em relação a deflexão angula, o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06; HCM diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .08 apresentou significantimente o maior valor até a fratura que os outros grupos (P<0.05). Nao foi encontrado diferença significativa entre PTG diâmetro 25, conicidade .08, LOG diâmetro 25, conicidade .06, e VB diâmetro 25, conicidade .06 (P<0.05). O EDM diâmetro 25, conicidade .08 apresentou a maior resistência a fadiga cíclica entre todos os instrumentos testados. Para o teste torsional, o PTG diâmetro 25, conicidade .08 apresentou o maior valor de torque e menor deflexão angular.
18

Avaliação in vitro da capacidade de corte e deformação de limas rotatórias de níquel-titânio / In vitro evaluation of the capability of cut and deformation of rotary nickeltitanium files

Paulo Roberto Baptista Reis 05 August 2009 (has links)
Objetivo: A busca incessante de melhorar o preparo do canal radicular faz com que novos instrumentos sejam projetados. Porém, diversos fatores como ângulo de corte, secção transversal, conformação da ponta e conicidade influenciam NBA fratura desses instrumentos. Sendo assim, o propósito da presente investigação foi avaliar in vitro a capacidade de corte e deformação de lima rotatória F2 do sistema ProTaper Universal e da lima 25/06 do sistema EndoSequence, ambas de níqueltitânio em função do número de usos. Método: Para realização deste estudo foi utilizada uma amostra não aleatória por conveniência de dez limas rotatórias F2 do Sistema ProTaper Universal e dez limas rotatórias n 25/06 do Sistema EndoSequence. Resultados: Na análise estatística descritiva do somatório dos desgastes das limas ProTaper Universal, o coeficiente de variação foi de 8,7%, e para o EndoSequence foi de 9,12%. Quando comparada a eficiência de corte dos somatórios de desgastes não verificou-se diferença estatisticamente significante entre as limas ProTaper Universal e as EndoSequence.. As limas F2 ProTaper Universal analisadas demonstraram perda de corte progressiva a partir do primeiro uso com estatística significante até o quinto uso, enquanto as limas 25/0,6 EndoSequence também demonstraram perda de corte progressiva significante do primeiro ao quinto uso com exceção do quarto uso onde não houve perda de corte significante em relação ao terceiro uso. Acredita-se que em função do exposto acima, quando se comparou a perda de corte dos diferentes usos entre os dois grupos só houve diferença estatística significante na comparação entre o quarto uso na qual as limas EndoSequence demonstraram melhor desempenho que as limas ProTaper Universal, no restante da comparação não houve diferença estatística significante entre as limas estudadas. Quanto à deformação das limas estudadas verificou-se que não houve diferença estatisticamente significante quando observadas em microscópio eletrônico de varredura. Conclusões: Mediante a metodologia utilizada e com base nos resultados obtidos concluiu-se que as limas ProTaper e EndoSequence apresentaram capacidade de corte semelhantes; no que se refere à deformação das limas, verificou-se que entre estas duas marcas utilizadas não houve diferença estatisticamente significante. / Aim: The search to improve root canal preparation makes new instruments are designed. However, several factors such as cutting angle, cross section, forming the tip and taper influence the fracture of these instruments. Therefore, the purpose of this investigation was to evaluate in vitro the ability to cut and deformation of rotating file F2 ProTaper Universal system and file system EndoSequence of 25/06, both nickel-titanium based on the number of uses. Methods: For this study we used a non-random convenience sample of ten files rotary F2 ProTaper Universal System and ten rotary files number 25/06 of System EndoSequence. Results: In the descriptive statistical analysis of the sum of the loss of files ProTaper Universal, the coefficient of variation was 8,7%, and the EndoSequence was 9,12%. When compared to the cutting efficiency of summation of damage there was no statistically significant difference between the files ProTaper Universal and EndoSequence. The F2 ProTaper Universal files examined showed progressive loss of cut from the first use with statistically significant until the fifth use, while the 25/06 EndoSequence files also demonstrated significant progressive loss of cutting from the first to the fifth use except the forth use, where there was no loss of significant cuts in relation to the third use. It is believed that based on the last sentence, when were compared the loss of cutting of different uses between both groups, there was only one statistically significant difference in the comparison between the forth uses, where the used EndoSequence files shows better performance than the ProTaper Universal files, and the rest of the comparison was not statistically significant between the files studied. As the deformation of the files examined it was found that there was no statistically significant when seen in the scanning electron microscope. Conclusions: Using the methodology used and based on the results obtained it was concluded that the ProTaper files and EndoSequence showed similar ability to cut, in relation to deformation of files, found that between these two marks used no difference statistically significant.
19

\"Resistência à fadiga cíclica flexural de instrumentos rotatórios de Ni-Ti em razão do uso e do torque\" / Flexural cyclic fatigue resistance of NiTi rotatory instruments due to number of users and torque.

Kawakami, Dirce Akemi Sacaguti 14 March 2007 (has links)
O objetivo do presente estudo foi avaliar a resistência à fadiga cíclica flexural de instrumentos rotatórios de níquel-titânio de número 25, conicidade 0,04 e 25 mm de comprimento (K3, SybronEndo), submetidos a variados torques de acionamento e repetidos ciclos de usos em canais simulados, valendo-se de dispositivo apropriado para ensaios dinâmicos. Procurou-se determinar se, além do fator de variação número de uso, há influência relacionada com o torque e, ainda, a possibilidade de interação entre número de uso e torque. Valendo-se motor elétrico acionado à velocidade de 300 rpm foram instrumentados 320 canais simulados, utilizado-se 80 instrumentos divididos em 4 grupos com 20 espécimes cada, de acordo com os torques (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm) a que seriam submetidos. Cada grupo foi subdividido em 4 subgrupos com 5 espécimes, de acordo com o número de usos (1, 3, 5 e 7 ciclos de usos). Todos os instrumentos foram submetidos a ensaio de fadiga cíclica flexural que foi realizado num dispositivo que permitia ao instrumento girar livremente, reproduzindo a instrumentação rotatória num canal curvo (40º e raio de curvatura de 5 mm), simulando o movimento de pecking, onde o instrumento deslizava pelo sulco criado no anel de aço temperado. Foi utilizada peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 300 rpm e torque idêntico ao empregado durante a fase de preparo dos canais simulados. A fratura do instrumento era facilmente detectada pelo sensor, e neste momento o contador e o temporizador paravam imediatamente. Os dados registrados no contador e no temporizador foram tranformados em segundos. Para a avaliação estatística empregou-se ANOVA e o teste t de Student (p<0,01). No que diz respeito ao fator de variação número de uso, não houve diferença estatística significante, enquanto as comparações feitas com o torque de 6,0 Ncm apresentaram valores de t calculado altamente significativo, com p < 0,01. Também não ocorreu interação significante entre os fatores de variação número de usos e torque. Baseado nos resultados deste estudo pode-se concluir que o torque afetou a resistência à fadiga cíclica flexural dos instrumentos rotatórios de NiTi, sendo menor naqueles submetidos à torque elevado, enquanto o número de usos em até 7 vezes não afetou . / The aim of the present study was to evaluate the flexural cyclic fatigue resistance of nickel-titanium rotary instruments, number 25, taper 0,04, and length of 25mm (K3, SybronEndo), when submitted to several torque values and number of uses in simulated canal blocks, by using devices appropriated for dynamic tests. It was tried to detect whether, in addition to the factor number of uses, there would be an influence related to torque, or even the possibility of an interaction between number of uses and torque. The data was collected from 320 simulated canals that were prepared, driven by an electrical motor at 300 rpm, using 80 instruments divided in 4 groups of 20 sample each, based on torque values (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm). Each group was randomly divided in 4 subgroups of 5 samples each, according to the number of uses (1, 3, 5 and 7 cycles). All files were submitted to flexural cyclic fatigue test realized in a device that allows the instrument to freely rotate, reproducing the movement of an instrument rotating in a curved canal (40º angle and 5 mm of radius), simulating the pecking movement, where the instrument slide over the groove created in the hardened steel. An electric motor hand-piece was used with a contra-angle 16:1 reduction set at 300 rpm and torque value identical to that used during preparation of simulated canals. The fracture of the instrument was easily detected at moment which the counter and the timer were immediately stopped. Data collected by the counter and the timer were converted in seconds and analysed by ANOVA and t Student test (p<0.01). In regards to the number of uses factor, there was not a statistically significant difference, while comparisons made with torque value set at 6,0 Ncm showed t values significantly high, with p<0.01. It was not seen any interaction between both variables, number of uses and torque. Based on the results of this investigation, it can be concluded that torque affected the resistance to flexural cyclic fatigue of nickel-titanium rotary instruments, being low on those tested at high torque value; while the factor number of uses up to 7 times did not affect the results.
20

Tratamento de lixiviado de aterro sanitário utilizando contactor biológico rotatório visando a remoção de nitrogênio amoniacal

Molz, Carine Helena 20 December 2013 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2015-05-07T18:11:50Z No. of bitstreams: 1 Carine Molz.pdf: 2307899 bytes, checksum: b2478459c37bae0098da022c723daeba (MD5) / Made available in DSpace on 2015-05-07T18:11:50Z (GMT). No. of bitstreams: 1 Carine Molz.pdf: 2307899 bytes, checksum: b2478459c37bae0098da022c723daeba (MD5) Previous issue date: 2013-12-20 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / UNISINOS - Universidade do Vale do Rio dos Sinos / A presente pesquisa propõe a utilização de um contactor biológico rotatório (CBR) com 4 estágios, no tratamento de lixiviado de aterro sanitário visando à remoção de matéria orgânica e nitrogênio amoniacal. Para auxiliar na nitrificação do nitrogênio amoniacal foi utilizado glicerina como fonte externa de carbono. O monitoramento da unidade experimental foi dividido em três etapas: Etapa 1 consistiu no uso de três estágios do CBR, com alimentação de 5,1 L/h, TDH de 24 hs e 12 RPM, Etapa 2 com as mesmas condições hidráulicas e a introdução da recirculação de 1,32 L/h do efluente para um estágio localizado antes do Estágio 1, e Etapa 3 que operou com as mesmas condições da Etapa 2, mais a adição de glicerina na razão 4,2 DQO:N no estágio 1 (entrada). O monitoramento dos seguintes parâmetros ocorreu semanalmente: alcalinidade, demanda bioquímica de oxigênio, demanda química de oxigênio, oxigênio dissolvido, pH, carbono inorgânico, carbono orgânico e carbono orgânico total, nitrogênio amoniacal, nitritos, nitratos, sólidos totais, sólidos suspensos totais, fixos e voláteis e fosfato. Esta abordagem buscou avaliar o desempenho do CBR no tratamento de lixiviado de aterro sanitário com baixa relação DBO5:DQO, visando a nitrificação do nitrogênio amoniacal e redução da matéria orgânica carbonácea. Durante o monitoramento da Etapa 1 foi observado acúmulo de nitritos e baixa produção de nitratos. O consumo de nitrogênio amoniacal foi de 682±274 mg N/L, DQO 335±925 mg O2/L e DBO568±106 mg O2/L. Na Etapa 2 o consumo de alcalinidade aumentou, porém ainda observou-se acúmulo de nitritos. A produção de nitratos aumentou em relação à Etapa 1, o consumo de nitrogênio amoniacal foi de 1.182±367 mg N/L, DQO 2.365±2.273 mg O2/L e DBO5510±90 mg O2/L. No monitoramento da Etapa 3, a adição de glicerina possibilitou um aumento na produção de nitratos, observando-se aumento significativo de sua concentração. O consumo de nitrogênio amoniacal foi de 742 ±139 mg N/L, DQO 1.558±558 mg O2/L e DBO5421±162 mg O2/L. No decorrer do monitoramento das Etapas pode-se observar que a glicerina e a recirculação auxiliaram na produção das bactérias oxidadoras de nitritos, porém ainda não o suficiente para a nitrificação completa do nitrogênio amoniacal afluente. / This research proposes the use of a rotating biological contactor (CBR) with 4 stages in the treatment of landfill leachate seeking the removal of organic matter and ammonia nitrogen. To help nitrification of ammonium nitrogen was usedas external carbon source glycerol. The monitoring of the experimental unit was divided into three steps: Step 1 consisted of three stages with power of 5.1 L/h, TDH 24 hours and 12 RPM, Step 2 with the same hydraulic conditions and the introduction of recirculation of1.32 L/h the effluent to a stage located before the stage 1, Step 3 and which was operated with the same conditions as Step 2 plus the addition of glycerin in the ratio 4.2 COD:N in the first stage (input). The monitoring of the following parameters occurred weekly: alkalinity, biochemical oxygen demand, total suspended chemical oxygen demand, dissolved oxygen, pH, inorganic carbon, organic carbon and total organic carbon, ammonia, nitrites, nitrates, total solids, solid, fixed and volatile and phosphate. This approach sought to evaluate the performance of RBC for the treatment of landfill leachate with a low BOD:COD, aiming nitrification of ammonia nitrogen and reduction of residual carbonaceous organic matter. During monitoring of Step 1 accumulation of nitrite and low nitrate production was observed, the consumption of ammonia nitrogen was 682±274 mg N/L, COD 335±925 mg O2/L and BOD 68±106 mg O2 /L. In Step 2 the consumption of alkalinity increased, but still there was accumulation of nitrite, nitrate production increased compared to Step 1, the consumption of ammonia nitrogen was 1.182±367 mg N/L, COD 2.365±2.273 mg O2/ L and BOD 90±510 mg O2/ L. Already, in the monitoring of Step 3, the addition of glycerin assited produce nitrates occurring significant increase in their concentrations, the presence of significant concentrations of nitrites, ammonia nitrogen consumption was 742±139 mg N/L, COD 1,558±558 mg O2/ L and BOD5 421±162 mg O2/ L. In the course of monitoring steps may be notedthat the recirculation glycerin supported in the production of nitrite-oxidizing bacteria, but still not enough for complete nitrification.

Page generated in 0.0494 seconds