• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 85
  • 1
  • Tagged with
  • 86
  • 86
  • 76
  • 66
  • 21
  • 18
  • 18
  • 14
  • 13
  • 13
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Medida de rugosidade por correlação angular de speckle / Measure of roughness by angle speckle correlation

Borbely, Luiz Alberto 18 January 2005 (has links)
Esse trabalho apresenta o método de correlação angular de speckle. Esse método foi melhorado para ser aplicado na medição de rugosidade na faixa de 30 m a 0,1 m. Um programa de computador foi desenvolvido para processar imagens e calcular a correlação angular, e novas fórmulas matemáticas foram deduzidas. / This work presents the speckle pattem angular correlation method. This method was improving to be applicable in the roughness measuring in the range of 0,1 m to 30 m. A software was developed to process image and to calculate the angular correlation, and new mathematical equations were formulating.
52

Comportamento mecânico, resistência de união e longevidade de pilares e coroas de zircônia obtidas por sistema CAD-CAM: influência de diferentes tratamentos de superfície / Mechanical behavior, bond strength and reliability of YTZP abutments and crowns processed by CAD/CAM: The role of surface treatments

Dantas, Talita Souza 29 April 2015 (has links)
O objetivo do estudo foi avaliar a resistência de união à zircônia após diferentes tratamentos de superfície e o comportamento mecânico de pilares e coroas de zircônia associados aos mesmos tratamentos. Na primeira fase, 95 discos em zircônia foram obtidos e divididos em cinco grupos (n = 19): GC (grupo controle, sem nenhum tipo de tratamento); GAL (jateamento com partículas de Al2O3 antes da sinterização); GALS (jateamento com partículas de Al2O3 após sinterização); GRO (silanização com sistema Rocatec antes da sinterização) e GROS (silanização com sistema Rocatec após sinterização). Três amostras de cada grupo tiveram a superfície analisada em MEV e MCVL. Dez amostras de cada grupo foram submetidas a ensaio de microcisalhamento e as seis restantes foram submetidas à análise de interface por meio de MEV. A análise estatística utilizou modelo de regressão linear com efeitos mistos e teste de Tukey (p < 0,01). Na segunda fase, 70 pilares do tipo hexágono externo foram obtidos em zircônia e associados a coroas totais com copings de zircônia. Os conjuntos análogo-pilar-coroa também foram divididos em cinco grupos (n=14) e submetidos aos mesmos tratamentos previamente descritos. Ainda, foram realizadas mensurações para verificação da adaptação dos copings sobre os pilares e rugosidade superficial dos discos, copings e pilares em MCVL. Foi realizado ensaio de fadiga mecânica dos conjuntos com carga progressiva de 80, 120, 160, 200, 240, 280 e 320 N, frequência de 5 Hz, totalizando 20.000 ciclos em cada estágio. A ciclagem térmica foi realizada com temperaturas entre 5º C e 55º C. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (probabilidade de sobrevida, teste de Log-Rang, p < 0,05) Os resultados apontaram que o grupo ROS apresentou valores de resistência de união significativamente superiores (p < 0,01) e que a rugosidade superficial foi semelhante para discos e copings (p = 0,22) e para discos e pilares (p = 0,96), e diferente entre copings e pilares (p < 0,01). A desadaptação marginal foi maior para o grupo RO (p < 0,01) e a probabilidade de sobrevida dos conjuntos foi similar para todos os grupos testados (p = 0,57). Concluiu-se que a utilização do Rocatec aumenta os valores de resistência de união à zircônia, não compromete o comportamento mecânico do material e sua utilização é viável em peças já sinterizadas. / The aim of this study was to evaluate the bond strength to zirconia after different surface treatments and to evaluate the mechanical behavior of zirconia abutments and crowns associated with these treatments. In the first phase, 95 discs in zirconia were obtained and divided into five groups (n = 19): GC (control group, without any treatment), GAL (air particle abrasion with Al2O3 particles before sintering), GALS (air particle abrasion with Al2O3 particles after sintering), GRO (silanization with Rocatec system before sintering) and GROS (silanization with Rocatec system after sintering). Three samples of each group had the surfaces analyzed in SEM and CLSM. Ten samples of each group were subjected to microshear test and the other remaining six had their interface examined by SEM. The statistical analysis used a linear regression model with mixed effects and Tukey test (p <0.01). In the second stage, 70 external hex abutments were obtained in zirconia and associated with crowns and zirconia copings. The analog-abutment-crown assemblies were also divided into five groups (n = 14) and subjected to the same treatments described previously. Measurements to verify the adaptation of copings on the abutments and surface roughness of the discs, copings and abutments were performed in CLSM. A fatigue test was carried with progressive load of 80, 120, 160, 200, 240, 280 and 320 N, frequency of 5 Hz and 20,000 cycles at each stage. Thermal cycling was performed with temperatures between 5° C and 55° C. After mechanical tests, the results were subjected to statistical analysis (survival probability, Log-Rang test, p <0.05) The results showed that the ROS group had significantly higher bond strength values (p < 0.01) and that the surface roughness was similar for discs and copings (p = 0.22) and for discs and abutments (p = 0.96), and was different between copings and abutments (p < 0.01). The marginal gap was higher for RO group (p < 0.01) and the survival probability of the sets was similar for all tested groups (p = 0.57). It was concluded that the use of Rocatec increases the bond strength values to zirconia, does not compromise the mechanical behavior of the material and its use is now feasible in sintered parts.
53

Efeito da escovação e enxaguatório bucal na alteração de cor e rugosidade de resinas compostas / Effect of toothbrushing and mouthwash on the color change and surface roughness of composite resins.

Trauth, Keico Graciela Sano 30 July 2010 (has links)
O presente estudo avaliou in vitro a influência de diferentes tipos de enxaguatórios bucais associados com a escovação, na alteração de cor e rugosidade superficial de diferentes tipos de resinas compostas diretas (M1- Filtek Supreme XT, M2- Z100, M3- Ice) por meio do espectrocolorímetro PCB 6807 da BYK-Gradner, rugosímetro modelo SJ-201P Mitutoyo e Microscopia Eletrônica de Varredura. Foram preparados 300 corpos de prova (n=10) para a variável alteração de cor, e destes espécimes 180 (n=6) foram submetidos ao ensaio de rugosidade superficial. Os espécimes foram polidos com discos Soft Lex, na sequência de abrasividade decrescente e armazenados em saliva artificial a 37°(±1°C) até o momento de serem submetidos nas soluções S1- Solução com álcool e com corante, Colgate Plax Fresh Mint; S2- Solução sem álcool e com corante, Oral-B; S3- Solução com álcool e sem corante, Cepacol; S4- Solução sem álcool e sem corante, Colgate Plax e S5- Grupo controle, Saliva Artificial e realização das leituras das variáveis em estudo, nos tempos T0- imediatamente após o polimento, T1- 7dias, T2- 14dias, e T3- 21dias. Todos os espécimes dos grupos experimentais foram imersos sob agitação, nos diferentes enxaguatórios bucais, 1 vez ao dia, por 2 minutos, durante 5 dias na semana. Após a realização de todas as leituras do estudo foram selecionados dois espécimes de maneira aleatória, de cada grupo experimental, totalizando 30 espécimes que foram submetidos a observação por médio de Microscopia Eletrônica de Varredura. Os dados de alteração de cor e de rugosidade superficial para cada uma das resinas, individualmente e para comparação das três resinas submetidas à escovação foram analisados por meio do teste ANOVA e Tukey (p&le;0,05). Os resultados para alteracao de cor mostraram que: o fator Solução foi significante somente para a resina Filtek Supreme XT, sendo a menor média S1 e a maior S3, por outro lado S2, S3, S4 e S5 foram estatisticamente iguais. O fator tratamento escovação foi significante para as resinas M2 e M3, sendo que para M2 a condição CES determinou maior média que SES e para M3, SES foi maior que CES. Para as três resinas o fator Tempo foi estatisticamente significante: a) M1 no T1 a média foi menor que em T2 e T3; b) para M2 a média em T1 foi menor que T2 e maior que T3; c) em M3, T1 foi igual a T2 que por sua vez foram menores que T3. Comparando o comportamento das três resinas constatou-se que M1 e M3 tiveram medias estatisticamente iguais e maiores que M2. Com relação à rugosidade superficial dos materiais M2 e M3, submetidos aos enxaguatórios utilizados neste estudo verificou-se que este fator não teve efeito estatisticamente significante; enquanto que para M1 houve diferença significante, assim, as médias de S1, S2 e S3 foram iguais e menores que as médias de S4 e S5. O fator tratamento escovação teve efeito significante somente para M1 sendo que a condição SES apresentou maior media que a CES. Com relação ao fator tempo verificou-se que para M1, a partir de T1, T2 e T3 as medias foram iguais entre si e maiores que T0; para M2 a maior media foi em T2 havendo igualdade estatística entre T0, T1 e T3; já para M3 as medias em T2 e T3 foram estatisticamente iguais e maiores que T0. Comparando as três resinas M1 apresentou maior rugosidade que M2 e M3 que foram estatisticamente iguais entre si. De acordo com a metodologia utilizada conclui-se que a alteração de cor das resinas estudadas foi influenciada pelo tempo; o tratamento escovação determinou alteração de cor para M2 e M3 e não foram influenciadas pelas soluções em estudo; M2 apresentou menor alteração que M1 e M3. Para rugosidade superficial conclui-se que o fator solução e o fator tratamento foram significantes somente para M1. O fator tempo influenciou a rugosidade das três resinas compostas. Relevância clinica: Há necessidade que o cirurgião dentista conheça as características das resinas compostas a ser utilizada no tratamento restaurador, além dos prováveis efeitos que os enxaguatórios bucais possam ter nas propriedades físicas do material, para assim indicá-los corretamente. / The present study evaluated in vitro the influence of different types of mouthwash associated with brushing, the color change and surface roughness of different types of direct composite resins (M1 - Filtek Supreme XT, M2 - Z100, M3 - Ice) through a PCB 6807 spectrocolorimeter of BYK-Gradner, rugosimeter model Mitutoyo SJ-201P and scanning electron microscopy. 300 specimens (n = 10) for the color alteration variable were prepared; of these, 180 specimens (n = 6) were subjected to tests surface roughness. The specimens were polished with discs Soft Lex (3M), following the decreasing abrasiveness sequence and stored in artificial saliva at 37 ° (±1 ° C) until be submitted in solutions S1 - solution with alcohol and dye, Colgate Plax Fresh Mint; S2 - solution without alcohol and with dye, Oral-B; S3 -solution with alcohol and without dye, Cepacol, S4 - Solution without alcohol and dye, Colgate Plax; S5 - Control Group, Artificial Saliva. The readings of the variables in study occurred in T0 - immediately after polishing, T1 7 days after, T2 14 days after and T3 21 days after. All specimens of the experimental groups were immersed with agitation in the different mouthrinses, once a day, for 2 minutes, during 5 days per week. After performing all readings of the study, two randomly selected specimens were chose from each experimental group, a total of 30 specimens were selected randomly and subjected to observation by scanning electronic microscopy. The data on color change and surface roughness for each resin were analyzed separately and together for comparison across the tests ANOVA and Turkey (p &le; 0.05). The results for color change demonstrated that the factor solution was significant only for Filtek Supreme XT resin, with S1 being the smallest and S3 the largest average. Still, S2, S3, S4 and S5 were statistically equal. The brushing treatment factor was significant for M2 and M3 resins, as the CES (with brushing) condition had a higher average than the SES (without brushing) one for M2; and for M3, SES was higher than CES. For the three resins, the time factor was significant: a) M1 at T1, the average was lower than in T2 and T3, b) to the M2 medium was lower than in T1 and T2 greater than T3, c) in M3, t1 was equal to t2 and both lower than T3. Comparing the behavior of the three resins, it was found that M1 and M3 average were statistically equal and higher than M2. Regarding the surface roughness of materials M2 and M3, submitted to rinses utilized in this study it was found that this factor had no statistically significant effect, while for M1 was significant difference, with the average of S1, S2 and S3 were equal and lower than the averages of S4 and S5. The factor brushing treatment effect was significant only for M1 being that the condition SES had a higher rating than the CES. Regarding the time factor, it was found that for M1, from T1, T2 and T3, the average was equal and higher than T0, for M2, the higher average was in T2, with statistical equality among T0, T1 and T3; for M3 average in T2 and T3 were statistically equal and greater than T0. Comparing the three resins, M1 showed higher roughness than M2 and M3 who were statistically equal. According to the used methodology, concludes that the color change of the resins was influenced by the time; treatment brushing determinate the color change for M2 and M3 and both were not influenced by the solutions under study; M2 showed lowest change than M1 and M3. For surface roughness is concluded that the factor solution and factor treatment were significant only for M1. The time factor influenced the roughness of the three composite resins. Clinical Relevance: It is necessary that dental surgeon know the characteristics of composite resins to be used in restorative treatment, beyond the likely effects that the mouthrinses may have on the physical properties of the material, to have correct indications.
54

Ultra-baixo coeficiente de atrito entre o par cerâmico Si3N4-Al2O3 em água. / Ultra-low friction coefficient between Si3N4-Al2O3 in water.

Ferreira, Vanderlei 08 September 2008 (has links)
Neste trabalho, foi investigado o comportamento tribológico dos pares cerâmicos aluminanitreto de silício no deslizamento em água e em uma suspensão de sílica coloidal em água (hidrosol). O objetivo foi verificar a possibilidade de atingir um coeficiente de atrito da ordem de unidades de milésimos, aqui chamado de ultra-baixo coeficiente de atrito (UBCA), verificar se a mudança do meio, de água para hidrosol, diminui o running-in do coeficiente de atrito, e verificar o efeito da variação da rugosidade inicial da alumina no comportamento do atrito. Os ensaios foram realizados na configuração de teste esferasobre- disco, no qual a esfera foi de nitreto de silício e o disco de alumina, sob carga normal de 54 N e velocidade de 1 m/s. A água utilizada nos ensaios foi destilada e deionizada, e a sílica coloidal amorfa, hidrofílica, sem porosidade e de tamanho médio de partícula de 12 nm foi a Aerosil® 200, e o hidrosol foi preparado com pH 8,5 num eletrólito de NaCl de 1 mM. A esfera de nitreto de silício, adquirida comercialmente, e a alumina, sinterizada em laboratório, foram caracterizadas quanto a densidade, as fases foram determinadas por difração de raios X, microscopia eletrônica de varedura (MEV) observada em amostras ceramográficas atacadas. Algumas propriedades mecânicas como dureza, módulo de elasticidade e tenacidade à fratura foram determinadas. Duas condições de rugosidade dos discos de alumina foram utilizadas nos ensaios tribológicos, 350 nm e 10 nm RMS. Em todos os ensaios, em água, em hidrosol e independentemente da rugosidade inicial do disco o coeficiente de atrito no regime permanente apresentou pequena dispersão de valores de 0,002 a 0,006, e não foi possível estabelecer diferença entre elas. A menor rugosidade do disco de alumina acarretou menor desgaste e menor período de running-in de coeficiente de atrito, tanto em água quanto em hidrosol. Os ensaios em meio de hidrosol acarretaram menor desgaste das cerâmicas e apresentaram menor running-in de coeficiente de atrito, comparados aos ensaios com água. O disco de alumina apresentou menor desgaste do que a esfera de nitreto de silício, em todas as condições estudadas. Com a análise das perdas volumétricas, da rugosidade final das superfícies desgastadas, das curvas de coeficiente de atrito e das espessuras mínimas de filme lubrificante, calculadas com uso de modelo da literatura, foi possível relacionar a diminuição do desgaste e do running-in de coeficiente de atrito em meio de hidrosol, com a presença da sílica na superfície ou próxima dela. / In this work, the tribological behavior of the alumina-silicon nitride couple was investigated under water and hydrosol (colloidal silica suspensions in water) lubricated sliding. The purposes were to study how an ultra-low friction coefficient can be achieved and to analyze the effects of the environment, lubricant and alumina roughness changes on the friction behavior. Ball-on-disk tests with a normal load of 54 N and a sliding speed of 1 m/s were carried out, using a silicon nitride ball and an alumina disk. The water used as lubricant was distilled and deionized. The silica was amorphous colloidal and hydrophilic, without porous and with a 12 nm medium particle diameter, commercially named Aerosil ® 200. The hydrosol was obtained with a pH value of 8,5 and a 1mM NaCl electrolyte. To estimate the minimum film thickness, formed during the lubricated sliding tests, a theory model was used. The commercial silicon nitride balls and the alumina disks, which were conformed and sintered in laboratory, were characterized by density, X-ray diffraction and scanning electron microscopy measurements. The mechanical properties such as hardness, Young modulus and fracture toughness were determined. The friction coefficient values obtained in the steady state regime showed low standard deviations (0,002 to 0,006) under all conditions. A shorter period of running-in was observed with the lower disk roughness, both in water and hydrosol lubrication. The hydrosol lubricated sliding produced a lower wear and friction running-in comparing with the tests under water lubrication. The alumina disk always showed lower wear than the silicon nitride ball. The volume loss, friction coefficients, worn surfaces roughness and minimum film thickness results suggest that the wear and friction coefficient running-in decrease was caused by the presence of silica on the sliding surfaces or on the near surface regions.
55

Comportamento mecânico, resistência de união e longevidade de pilares e coroas de zircônia obtidas por sistema CAD-CAM: influência de diferentes tratamentos de superfície / Mechanical behavior, bond strength and reliability of YTZP abutments and crowns processed by CAD/CAM: The role of surface treatments

Talita Souza Dantas 29 April 2015 (has links)
O objetivo do estudo foi avaliar a resistência de união à zircônia após diferentes tratamentos de superfície e o comportamento mecânico de pilares e coroas de zircônia associados aos mesmos tratamentos. Na primeira fase, 95 discos em zircônia foram obtidos e divididos em cinco grupos (n = 19): GC (grupo controle, sem nenhum tipo de tratamento); GAL (jateamento com partículas de Al2O3 antes da sinterização); GALS (jateamento com partículas de Al2O3 após sinterização); GRO (silanização com sistema Rocatec antes da sinterização) e GROS (silanização com sistema Rocatec após sinterização). Três amostras de cada grupo tiveram a superfície analisada em MEV e MCVL. Dez amostras de cada grupo foram submetidas a ensaio de microcisalhamento e as seis restantes foram submetidas à análise de interface por meio de MEV. A análise estatística utilizou modelo de regressão linear com efeitos mistos e teste de Tukey (p < 0,01). Na segunda fase, 70 pilares do tipo hexágono externo foram obtidos em zircônia e associados a coroas totais com copings de zircônia. Os conjuntos análogo-pilar-coroa também foram divididos em cinco grupos (n=14) e submetidos aos mesmos tratamentos previamente descritos. Ainda, foram realizadas mensurações para verificação da adaptação dos copings sobre os pilares e rugosidade superficial dos discos, copings e pilares em MCVL. Foi realizado ensaio de fadiga mecânica dos conjuntos com carga progressiva de 80, 120, 160, 200, 240, 280 e 320 N, frequência de 5 Hz, totalizando 20.000 ciclos em cada estágio. A ciclagem térmica foi realizada com temperaturas entre 5º C e 55º C. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (probabilidade de sobrevida, teste de Log-Rang, p < 0,05) Os resultados apontaram que o grupo ROS apresentou valores de resistência de união significativamente superiores (p < 0,01) e que a rugosidade superficial foi semelhante para discos e copings (p = 0,22) e para discos e pilares (p = 0,96), e diferente entre copings e pilares (p < 0,01). A desadaptação marginal foi maior para o grupo RO (p < 0,01) e a probabilidade de sobrevida dos conjuntos foi similar para todos os grupos testados (p = 0,57). Concluiu-se que a utilização do Rocatec aumenta os valores de resistência de união à zircônia, não compromete o comportamento mecânico do material e sua utilização é viável em peças já sinterizadas. / The aim of this study was to evaluate the bond strength to zirconia after different surface treatments and to evaluate the mechanical behavior of zirconia abutments and crowns associated with these treatments. In the first phase, 95 discs in zirconia were obtained and divided into five groups (n = 19): GC (control group, without any treatment), GAL (air particle abrasion with Al2O3 particles before sintering), GALS (air particle abrasion with Al2O3 particles after sintering), GRO (silanization with Rocatec system before sintering) and GROS (silanization with Rocatec system after sintering). Three samples of each group had the surfaces analyzed in SEM and CLSM. Ten samples of each group were subjected to microshear test and the other remaining six had their interface examined by SEM. The statistical analysis used a linear regression model with mixed effects and Tukey test (p <0.01). In the second stage, 70 external hex abutments were obtained in zirconia and associated with crowns and zirconia copings. The analog-abutment-crown assemblies were also divided into five groups (n = 14) and subjected to the same treatments described previously. Measurements to verify the adaptation of copings on the abutments and surface roughness of the discs, copings and abutments were performed in CLSM. A fatigue test was carried with progressive load of 80, 120, 160, 200, 240, 280 and 320 N, frequency of 5 Hz and 20,000 cycles at each stage. Thermal cycling was performed with temperatures between 5° C and 55° C. After mechanical tests, the results were subjected to statistical analysis (survival probability, Log-Rang test, p <0.05) The results showed that the ROS group had significantly higher bond strength values (p < 0.01) and that the surface roughness was similar for discs and copings (p = 0.22) and for discs and abutments (p = 0.96), and was different between copings and abutments (p < 0.01). The marginal gap was higher for RO group (p < 0.01) and the survival probability of the sets was similar for all tested groups (p = 0.57). It was concluded that the use of Rocatec increases the bond strength values to zirconia, does not compromise the mechanical behavior of the material and its use is now feasible in sintered parts.
56

Efeito da escovação e enxaguatório bucal na alteração de cor e rugosidade de resinas compostas / Effect of toothbrushing and mouthwash on the color change and surface roughness of composite resins.

Keico Graciela Sano Trauth 30 July 2010 (has links)
O presente estudo avaliou in vitro a influência de diferentes tipos de enxaguatórios bucais associados com a escovação, na alteração de cor e rugosidade superficial de diferentes tipos de resinas compostas diretas (M1- Filtek Supreme XT, M2- Z100, M3- Ice) por meio do espectrocolorímetro PCB 6807 da BYK-Gradner, rugosímetro modelo SJ-201P Mitutoyo e Microscopia Eletrônica de Varredura. Foram preparados 300 corpos de prova (n=10) para a variável alteração de cor, e destes espécimes 180 (n=6) foram submetidos ao ensaio de rugosidade superficial. Os espécimes foram polidos com discos Soft Lex, na sequência de abrasividade decrescente e armazenados em saliva artificial a 37°(±1°C) até o momento de serem submetidos nas soluções S1- Solução com álcool e com corante, Colgate Plax Fresh Mint; S2- Solução sem álcool e com corante, Oral-B; S3- Solução com álcool e sem corante, Cepacol; S4- Solução sem álcool e sem corante, Colgate Plax e S5- Grupo controle, Saliva Artificial e realização das leituras das variáveis em estudo, nos tempos T0- imediatamente após o polimento, T1- 7dias, T2- 14dias, e T3- 21dias. Todos os espécimes dos grupos experimentais foram imersos sob agitação, nos diferentes enxaguatórios bucais, 1 vez ao dia, por 2 minutos, durante 5 dias na semana. Após a realização de todas as leituras do estudo foram selecionados dois espécimes de maneira aleatória, de cada grupo experimental, totalizando 30 espécimes que foram submetidos a observação por médio de Microscopia Eletrônica de Varredura. Os dados de alteração de cor e de rugosidade superficial para cada uma das resinas, individualmente e para comparação das três resinas submetidas à escovação foram analisados por meio do teste ANOVA e Tukey (p&le;0,05). Os resultados para alteracao de cor mostraram que: o fator Solução foi significante somente para a resina Filtek Supreme XT, sendo a menor média S1 e a maior S3, por outro lado S2, S3, S4 e S5 foram estatisticamente iguais. O fator tratamento escovação foi significante para as resinas M2 e M3, sendo que para M2 a condição CES determinou maior média que SES e para M3, SES foi maior que CES. Para as três resinas o fator Tempo foi estatisticamente significante: a) M1 no T1 a média foi menor que em T2 e T3; b) para M2 a média em T1 foi menor que T2 e maior que T3; c) em M3, T1 foi igual a T2 que por sua vez foram menores que T3. Comparando o comportamento das três resinas constatou-se que M1 e M3 tiveram medias estatisticamente iguais e maiores que M2. Com relação à rugosidade superficial dos materiais M2 e M3, submetidos aos enxaguatórios utilizados neste estudo verificou-se que este fator não teve efeito estatisticamente significante; enquanto que para M1 houve diferença significante, assim, as médias de S1, S2 e S3 foram iguais e menores que as médias de S4 e S5. O fator tratamento escovação teve efeito significante somente para M1 sendo que a condição SES apresentou maior media que a CES. Com relação ao fator tempo verificou-se que para M1, a partir de T1, T2 e T3 as medias foram iguais entre si e maiores que T0; para M2 a maior media foi em T2 havendo igualdade estatística entre T0, T1 e T3; já para M3 as medias em T2 e T3 foram estatisticamente iguais e maiores que T0. Comparando as três resinas M1 apresentou maior rugosidade que M2 e M3 que foram estatisticamente iguais entre si. De acordo com a metodologia utilizada conclui-se que a alteração de cor das resinas estudadas foi influenciada pelo tempo; o tratamento escovação determinou alteração de cor para M2 e M3 e não foram influenciadas pelas soluções em estudo; M2 apresentou menor alteração que M1 e M3. Para rugosidade superficial conclui-se que o fator solução e o fator tratamento foram significantes somente para M1. O fator tempo influenciou a rugosidade das três resinas compostas. Relevância clinica: Há necessidade que o cirurgião dentista conheça as características das resinas compostas a ser utilizada no tratamento restaurador, além dos prováveis efeitos que os enxaguatórios bucais possam ter nas propriedades físicas do material, para assim indicá-los corretamente. / The present study evaluated in vitro the influence of different types of mouthwash associated with brushing, the color change and surface roughness of different types of direct composite resins (M1 - Filtek Supreme XT, M2 - Z100, M3 - Ice) through a PCB 6807 spectrocolorimeter of BYK-Gradner, rugosimeter model Mitutoyo SJ-201P and scanning electron microscopy. 300 specimens (n = 10) for the color alteration variable were prepared; of these, 180 specimens (n = 6) were subjected to tests surface roughness. The specimens were polished with discs Soft Lex (3M), following the decreasing abrasiveness sequence and stored in artificial saliva at 37 ° (±1 ° C) until be submitted in solutions S1 - solution with alcohol and dye, Colgate Plax Fresh Mint; S2 - solution without alcohol and with dye, Oral-B; S3 -solution with alcohol and without dye, Cepacol, S4 - Solution without alcohol and dye, Colgate Plax; S5 - Control Group, Artificial Saliva. The readings of the variables in study occurred in T0 - immediately after polishing, T1 7 days after, T2 14 days after and T3 21 days after. All specimens of the experimental groups were immersed with agitation in the different mouthrinses, once a day, for 2 minutes, during 5 days per week. After performing all readings of the study, two randomly selected specimens were chose from each experimental group, a total of 30 specimens were selected randomly and subjected to observation by scanning electronic microscopy. The data on color change and surface roughness for each resin were analyzed separately and together for comparison across the tests ANOVA and Turkey (p &le; 0.05). The results for color change demonstrated that the factor solution was significant only for Filtek Supreme XT resin, with S1 being the smallest and S3 the largest average. Still, S2, S3, S4 and S5 were statistically equal. The brushing treatment factor was significant for M2 and M3 resins, as the CES (with brushing) condition had a higher average than the SES (without brushing) one for M2; and for M3, SES was higher than CES. For the three resins, the time factor was significant: a) M1 at T1, the average was lower than in T2 and T3, b) to the M2 medium was lower than in T1 and T2 greater than T3, c) in M3, t1 was equal to t2 and both lower than T3. Comparing the behavior of the three resins, it was found that M1 and M3 average were statistically equal and higher than M2. Regarding the surface roughness of materials M2 and M3, submitted to rinses utilized in this study it was found that this factor had no statistically significant effect, while for M1 was significant difference, with the average of S1, S2 and S3 were equal and lower than the averages of S4 and S5. The factor brushing treatment effect was significant only for M1 being that the condition SES had a higher rating than the CES. Regarding the time factor, it was found that for M1, from T1, T2 and T3, the average was equal and higher than T0, for M2, the higher average was in T2, with statistical equality among T0, T1 and T3; for M3 average in T2 and T3 were statistically equal and greater than T0. Comparing the three resins, M1 showed higher roughness than M2 and M3 who were statistically equal. According to the used methodology, concludes that the color change of the resins was influenced by the time; treatment brushing determinate the color change for M2 and M3 and both were not influenced by the solutions under study; M2 showed lowest change than M1 and M3. For surface roughness is concluded that the factor solution and factor treatment were significant only for M1. The time factor influenced the roughness of the three composite resins. Clinical Relevance: It is necessary that dental surgeon know the characteristics of composite resins to be used in restorative treatment, beyond the likely effects that the mouthrinses may have on the physical properties of the material, to have correct indications.
57

Caracterização da usinabilidade de ultraprecisão em ligas de alumínio fabricadas no Brasil / not available

Jasinevicius, Renato Goulart 26 August 1994 (has links)
O objetivo deste trabalho foi identificar a influência das condições de usinagem sobre o acabamento superficial no faceamento de uma liga de alumínio com ferramenta de diamante. Os parâmetros de corte variados foram: velocidade de corte, avanço e profundidade de corte. De acordo com a bibliografia consultada apenas o avanço e o raio de ponta da ferramenta afetam diretamente o acabamento superficial, sendo que quanto menor o avanço e maior o raio de ponta melhor será o resultado em termos de rugosidade superficial. A profundidade de corte é dita apenas influenciar na força de corte e não no acabamento. Outro parâmetro de corte que segundo a bibliografia não apresenta influência seria a velocidade de corte, sendo que sua variação não afeta os resultados de acabamento superficial. Os ensaios demonstraram que dentre as condições de corte estudadas o avanço é o parâmetro de maior influência, com os menores valores de rugosidade obtidos para um avanço de 2 &#956m/rev. A profundidade de corte apresentou pouca influência no acabamento, apresentando um efeito previsto pela literatura, o \"size effect\", a uma profundidade de corte de 3 &#956m, e a velocidade de corte não apresentou influência. A liga de alumínio testada foi a 7075-T6. Utilizou-se uma ferramenta de diamante monocristalino nova com raio de ponta de 1.524 mm e ângulos de folga e de saída de 11º e 0º, respectivamente. / The objective of this work was to identify the influence of the cutting conditions on surface roughness of an aluminum alloy faced with a single-point diamond tool. The cutting parameters to be varied were: feedrate, depth of cut and cutting speed. According to the literature, only the feedrate and the tool nose radius have direct influence on surface roughness, in the following way: The lower the feedrate and the greater the nose radius, the better the surface roughness. The depth of cut is said only to influence on the cutting forces and do not affect the surface roughness. The cutting speed also has no influence on surface roughness, according to the literature. Experimental investigation has demonstrated that, among the tested cutting conditions, the feedrate has the most influence with low values of surface roughness obtained at a feedrate of 2 &#956m/rev. The depth of cut has very little influence on the surface finish. lt just showed an effect foreseen by the literature, the size effect, at a depth of cut of 3 &#956m and the cutting speed has not showed any influence. The aluminum alloy investigated was 7075-T6. A fresh diamond tool was used, with a nose radius of 1.524 mm and 11º and 0º clearance and rake angle, respectively.
58

Influência de agentes clareadores na rugosidade de compósitos dentários / Influence of bleaching gels on roughness of dental composites

Eduardo Varanda 18 December 2009 (has links)
O clareamento dental é o meio disponível mais simples, comum e conservador para o cirurgião-dentista proporcionar aos pacientes o padrão de cor de seus dentes mais desejado. Em alguns casos, os dentes que vão ser clareados podem apresentar restaurações realizadas com compósitos dentais, que são mais suscetíveis a alterações químicas, quando comparados a outros materiais restauradores. Alguns estudos mostraram que diferentes concentrações de agentes clareadores levaram a um aumento significativo da rugosidade superficial e das porosidades em compósitos dentais. Este estudo avaliou o efeito de dois agentes clareadores (Whiteness HP Blue 20%, Whiteness HP Max) sobre a rugosidade superficial de dois compósitos dentais, um micro-híbrido (Esthet X, Denstply) e outro nanoparticulado (Z 350, 3M ESPE). Um total de oito corpos de prova (9 x 2 mm) foram confeccionados com auxílio de uma matriz de teflon, sendo divididos em 4 grupos (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), sendo n=2. Os corpos de prova foram armazenados em saliva artificial neutra e, após 24 horas, foram polidos com discos de óxido de Alumínio (Sof-lex, 3M ESPE). Após sete dias de imersão salivar, cada corpo de prova foi levado a um microscópio de força atômica para obtenção do valor inicial de rugosidade superficial (Ra em nm). Em seguida, sem remover o corpo de prova do microscópio, o agente clareador foi aplicado sobre a superfície do corpo de prova, segundo as instruções do fabricante, de modo que permitisse uma posterior observação da mesma área do corpo de prova observada inicialmente, para obtenção do valor final de rugosidade superficial. Imagens em duas e três dimensões foram obtidas de cada corpo de prova para observação de alterações da topografia. Os resultados foram tratados estatisticamente por ANOVA e pelo teste de contraste Student-Newman-Keuls (p < 0,05). Não houve alteração significativa na rugosidade superficial (Ra) dos corpos da prova de compósitos micro-híbrido e nanoparticulado, submetidos aos agentes clareadores Whiteness HP Blue 20% e Whiteness HP Maxx. No entanto, independente do agente clareador utilizado, foram observadas maiores alterações topográficas nas imagens de microscopia de força atômica da superfície do compósito micro-híbrido do que nas imagens do nanoparticulado. / Dental bleaching is the simplest, the most common and conservative available way for dentists to offer their patients the standard color of teeth more desired. In some cases, the teeth that will be bleached may include restorations made of resin composites, which are more prone to chemical alteration compared with other restoration materials. Some studies have showed that different concentrations of bleaching gels might lead to a significant increase in surface roughness and amount of porosities in composite resins. This study evaluated the effect of two bleaching gels (Whiteness HP Blue 20%, Whiteness HP Max) on surface roughness of two resin composites, micro-hybrid (Esthet X, Denstply) and nanoparticled (Z350, 3M ESPE). A total of eight specimens (9 x 2 mm) were produced with a Teflon mold help, and were divided into four groups (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), with n=2. They were stored in neutral artificial saliva and, after 24 hours, were polished with aluminium oxide discs (Sof-lex, 3M ESPE). After seven days of salivary immersion, each specimen was taken to an atomic force microscope for recording initial value of surface roughness (Ra in nm). After that procedure, without removing the specimen from microscope, the bleaching gel was applied on the surface of the specimen, following manufacturers instructions, in order to allow posterior observation of the same area of the specimen initially observed, for recording the final value of surface roughness. Two-dimensional and 3D images were taken from each specimen group for observation of surface alterations. The results were statistically analyzed by ANOVA and the SNK test (p< 0.05). There were no statistically significant differences in the surface roughness (Ra) for specimens of micro-hybrid and nanoparticled composites, submitted to the bleaching agents Whiteness HP Blue 20% and Whiteness HP Maxx. However, there were noticed larger surface alterations in atomic force microscope images on the surface of micro-hybrid composites than on the nanoparticled, independently of the bleaching agent used.
59

Caracterização da usinabilidade de ultraprecisão em ligas de alumínio fabricadas no Brasil / not available

Renato Goulart Jasinevicius 26 August 1994 (has links)
O objetivo deste trabalho foi identificar a influência das condições de usinagem sobre o acabamento superficial no faceamento de uma liga de alumínio com ferramenta de diamante. Os parâmetros de corte variados foram: velocidade de corte, avanço e profundidade de corte. De acordo com a bibliografia consultada apenas o avanço e o raio de ponta da ferramenta afetam diretamente o acabamento superficial, sendo que quanto menor o avanço e maior o raio de ponta melhor será o resultado em termos de rugosidade superficial. A profundidade de corte é dita apenas influenciar na força de corte e não no acabamento. Outro parâmetro de corte que segundo a bibliografia não apresenta influência seria a velocidade de corte, sendo que sua variação não afeta os resultados de acabamento superficial. Os ensaios demonstraram que dentre as condições de corte estudadas o avanço é o parâmetro de maior influência, com os menores valores de rugosidade obtidos para um avanço de 2 &#956m/rev. A profundidade de corte apresentou pouca influência no acabamento, apresentando um efeito previsto pela literatura, o \"size effect\", a uma profundidade de corte de 3 &#956m, e a velocidade de corte não apresentou influência. A liga de alumínio testada foi a 7075-T6. Utilizou-se uma ferramenta de diamante monocristalino nova com raio de ponta de 1.524 mm e ângulos de folga e de saída de 11º e 0º, respectivamente. / The objective of this work was to identify the influence of the cutting conditions on surface roughness of an aluminum alloy faced with a single-point diamond tool. The cutting parameters to be varied were: feedrate, depth of cut and cutting speed. According to the literature, only the feedrate and the tool nose radius have direct influence on surface roughness, in the following way: The lower the feedrate and the greater the nose radius, the better the surface roughness. The depth of cut is said only to influence on the cutting forces and do not affect the surface roughness. The cutting speed also has no influence on surface roughness, according to the literature. Experimental investigation has demonstrated that, among the tested cutting conditions, the feedrate has the most influence with low values of surface roughness obtained at a feedrate of 2 &#956m/rev. The depth of cut has very little influence on the surface finish. lt just showed an effect foreseen by the literature, the size effect, at a depth of cut of 3 &#956m and the cutting speed has not showed any influence. The aluminum alloy investigated was 7075-T6. A fresh diamond tool was used, with a nose radius of 1.524 mm and 11º and 0º clearance and rake angle, respectively.
60

Avaliação de diversos métodos para remoção da resina remanescente após descolagem de bráquetes ortodônticos

Cabral, Fátima Gouveia January 2006 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:11:38Z No. of bitstreams: 1 Dissertação - Fatima Cabral.pdf: 3063741 bytes, checksum: 2fef60738a8888a178499680d9647e2d (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:35:58Z (GMT) No. of bitstreams: 1 Dissertação - Fatima Cabral.pdf: 3063741 bytes, checksum: 2fef60738a8888a178499680d9647e2d (MD5) / Made available in DSpace on 2013-05-08T12:35:58Z (GMT). No. of bitstreams: 1 Dissertação - Fatima Cabral.pdf: 3063741 bytes, checksum: 2fef60738a8888a178499680d9647e2d (MD5) Previous issue date: 2006 / O objetivo deste estudo foi avaliar as alterações na superfície do esmalte, decorrentes da utilização de 5 técnicas distintas para a remoção da resina remanescente após a descolagem de bráquetes ortodônticos. Foram analisados 50 pré-molares humanos, extraídos por fins ortodônticos e periodontais, cujas faces vestibulares foram submetidas à análise rugosimétrica de superfície, executada em 3 momentos distintos: 1- inicial; 2- após a colagem, remoção de bráquetes e eliminação da resina remanescente; 3- após o polimento final. Nos grupos 1 e 2, utilizou-se a broca carbide de tungstênio em baixa e alta rotação, respectivamente. Para os grupos 3 e 4, o instrumento empregado foi a broca carbide de tungstênio proposta por Radlanski, também em baixa e alta rotação, respectivamente. Nestes 4 primeiros grupos, o polimento consistiu na utilização de discos de óxido de alumínio de granulação superfina. O grupo 5 foi representado pela associação de alicate removedor de resina e ponta de carboneto de silício em alta rotação, seguidos por polimento com pontas de borracha com grânulos de diamante em baixa rotação. Os resultados demonstraram que, após a remoção da resina, os menores valores de rugosidade superficial foram obtidos com a utilização da broca carbide de tungstênio em baixa rotação (grupo 1) e com as brocas propostas por Radlanski, tanto em baixa (grupo 3) quanto em alta rotação (grupo 4). Já a broca carbide de tungstênio em alta rotação (grupo 2) e o alicate removedor de resina associado às pontas de carboneto de silício e borracha (grupo 5)apresentaram valores de rugosidade média estatisticamente superiores aos demais grupos. Com o polimento, passou a existir diferença estatisticamente significante apenas em relação ao grupo 5, o qual revelou maior rugosidade do que os demais. A avaliação visual foi realizada por 3 examinadores e não detectou diferença estatisticamente significante entre os métodos utilizados. A partir destes dados, concluiu-se que a broca carbide de tungstênio em baixa rotação (grupo 1) e as brocas propostas por Radlanski (grupos 3 e 4) representaram métodos menos agressivos ao esmalte dentário para a remoção da resina remanescente após a descolagem de bráquetes. / Salvador

Page generated in 0.0686 seconds