• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 96
  • 31
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 157
  • 87
  • 40
  • 36
  • 36
  • 31
  • 28
  • 27
  • 23
  • 23
  • 22
  • 20
  • 20
  • 20
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Limpeza das paredes dos canais radiculares promovida por agentes desmineralizantes e quelantes: estudo in vitro por microscopia eletrônica de varredura e espectrofotometria dos compostos / Root canal wall clean by demineralize and chelating agents: scanning electron microscope and atomic absorption spectroscopy in vitro study

Julio César Emboava Spanó 15 February 2008 (has links)
Este trabalho teve por objetivo estudar a capacidade da remoção da camada de smear das paredes do canal radicular, pelas soluções de EDTA a 15%, ácido cítrico a 10%, citrato de sódio a 10%, vinagre de maçã, ácido acético a 5%, ácido málico a 5% e hipoclorito de sódio a 1% por meio da microscopia eletrônica de varredura e quantificar a concentração de ions cálcio presentes nessas soluções após suas utilizações, por meio da espectrofotometria de absorção atômica de chama. Utilizaram-se 42 dentes incisivos centrais superiores, nos quais se realizou a cirurgia de acesso, remoção de ombro cervical e desgaste compensatório. Aferiu-se o comprimento de trabalho com uma lima tipo K, diâmetro #10 introduzida no canal radicular de cada dente até ser visualizada no ápice, subtraindo-se um milímetro. Determinou-se também o diâmetro anatômico do canal do dente no comprimento de trabalho por meio da introdução de instrumentos tipo K da primeira série com diâmetros sucessivamente maiores, que foi anotado quando um dos instrumentos sofresse resistência ao ser retirado do comprimento de trabalho. Todos os dentes que apresentaram diâmetro anatômico do canal acima de 40 centésimos de milímetros foram descartados e repostos por outros. Desta forma, garantiu-se o desgaste de 20 centésimos de milímetros no terço apical. A técnica utilizada foi a Free Tip Preparation (PECORA et al. 2002) até que um instrumento de diâmetro #60 e taper .04 percorresse todo o comprimento de trabalho. Utilizou-se a solução de hipoclorito de sódio a 1,0% durante todo o preparo biomecânico. Os dentes tiveram seus canais radiculares lavados com 20 mililitros de água deionizada para a remoção de possíveis raspas de dentina soltas no interior do canal radicular. Após o término do preparo biomecânico, os dentes foram divididos aleatoriamente em 7 grupos de 6 dentes cada, de acordo com a substância química utilizada para a irrigação final, a saber: G1 - solução de EDTA a 15,0%; G2 - solução de ácido cítrico a 10,0%; G3 - solução de citrato de sódio a 10,0%; G4 - vinagre de maçã; G5 - solução de ácido acético a 5,0%; G6 - solução de ácido málico a 5,0% e G7 - sem irrigação final (controle negativo). O tempo de permanência das soluções nos canais radiculares foi de 5 minutos. Os dentes foram clivados no sentido vestíbulo-palatino e encaminhados para a microscopia eletrônica de varredura, em que se obtiveram fotomicrografias com o aumento de 1000 vezes. As soluções coletadas foram encaminhadas para a análise química, realizada com um espectrofotômetro de absorção atômica de chama. Concluiu-se que o EDTA a 15% e o ácido cítrico a 10% são eficientes para a remoção da camada de smear. O vinagre de maçã, o citrato de sódio a 10%, os ácidos acético e málico a 5% e o hipoclorito de sódio não foram eficientes para a mesma finalidade. O EDTA a 15% apresentou a maior concentração de ions cálcio em solução; o ácido cítrico a 10% ficou na segunda posição e a terceira foi ocupada pelo vinagre de maçã e os ácidos acético e málico a 5%. A menor concentração de íons cálcio foi encontrada no citrato de sódio a 10%. / This study evaluated the smear layer removal capacity of 15% EDTA, 10% citric acid, 10% sodium citrate, apple vinegar, 5% acetic acid and 1% sodium hypochlorite using scanning electron microscopy and flame atomic absorption spectrophotometry. Forty two central superior incisives were used. On these teeth, it were accomplished the access surgery, removal of cervical shoulder and compensatory wear. The working length was checked with a #10 K-type file that was introduced in the radicular canal of each tooth until be visualized at the apex, then a millimeter was subtracted. The anatomical diameter of the canal in the working length was also determined through the introduction of K-type instruments of the first series with successively larger diameters. The anatomical diameter of the radicular canal was notated when one of the instruments showed resistance to be removed from the working length. All the teeth that presented the canal diameter in the working length above 40 hundredths millimeters were discarded and replaced by other. This way, it was obtained a standard wear of 20 hundredths millimeters in the apical third. The Free Tip Preparation technique (PECORA et al. 2002) was used until a #60- diameter instrument and .04 taper reached the entire working length. The 1.0% sodium hypoclorite solution was used during biomechanical preparation. The teeth had their radicular canals washed with 20 milliliters of deionized water, using Milli-Q® water purification system, for removal of possible dentine chips presented inside the root canal. After the biomechanical preparation, the teeth were randomly divided into 7 groups of 6 teeth each: group 1: teeth with final irrigation with 15% EDTA solution, group 2: teeth with final irrigation with 10%citric acid solution, group 3: final irrigation with 10% sodium citrate solution, group 4: final irrigation with apple vinegar, group 5: final irrigation with 5% acetic acid solution, group 6: final irrigation with 5% maleic acid solution and group 7: teeth only instrument and irrigated with sodium hypochlorite, without final irrigation. Each solution remained 5 minutes in the radicular canal. The cleavage of teeth was done in buccal-palatine direction and they were subjected to the scanning electron microscopy and photographed at 1000X. The collected solutions were submitted to chemical analysis through flame atomic absorption spectrophotometry. It was concluded that 15% EDTA and 10% citric acid, used for 5 minutes, are effective in removing the smear layer. The apple vinegar, 10% sodium citrate, 5% acetic and maleic acids and sodium hypochlorite were not effective in removing the smear layer from root canal. 15% EDTA presented a higher concentration of calcium ions in solution, followed by 10% citric acid. Intermediary results were observed by apple vinegar, 5% acetic and maleic acids, and the inferior concentration of calcium ions was obtained with the 10% sodium citrate.
42

Avaliação in vitro da remoção da camada residual (smear layer) de canais radiculares achatados instrumentados com quatro diferentes sistemas rotatórios com e sem associação de ultra-som e laser ER:YAG / Evaluation of smear layer removal of flatted canals after rotary instrumentation with four diferent NiTi instruments and association with Laser Er:YAG and ultrasonic

Alexandre Capelli 13 March 2008 (has links)
Estudou-se, por meio da microscopia eletrônica de varredura, a remoção da \"smear layer\" dos canais radiculares preparados com sistemas rotatórios com e sem \"radial land\". Após a preparação, as paredes dos canais radiculares foram submetidas aos tratamentos com ultra-som, aplicação do agente quelante EDTA a 15% e do laser Er:YAG. Noventa e seis incisivos inferiores humanos foram selecionados e divididos aleatoriamente em quatro grupos distintos, preparados com técnica rotatória Free Tip (Pecora et al, 2002) com instrumentos de níquel-titânio, 0,5 mm aquém do ápice anatômico, variando-se apenas o tratamento final das paredes do canal radicular. No grupo 1 utilizou-se o hipoclorito de sódio a 2,5% durante a instrumentação; no grupo 2 realizou-se irrigação com hipoclorito de sódio a 2,5% durante a instrumentação, recebendo posteriormente irradiação com laser Er:YAG (KaVo Key Laser II), com o auxílio de uma fibra óptica 30/28 de 285 &micro;m de diâmetro, gerando uma energia total de 42 J, freqüência de 15 Hz e potencia de 250mJ input (140mJ output). A cinemática utilizada na irradiação foi de movimento helicoidal de tração da fibra óptica, de apical para cervical, durante 10 segundos, sendo repetida quatro vezes; no grupo 3 utilizou-se a solução de hipoclorito de sódio a 2,5% ativada pelo ultra-som (MiniPiezon, EMS, Suíça); no grupo 4 utilizou-se a solução de hipoclorito de sódio a 2,5% e irrigação final com EDTA a 17%. Os espécimes foram preparados para microscopia eletrônica de varredura, e as fotomicrografias obtidas dos terços médio e apical submetidas a avaliação qualitativa por três observadores previamente calibrados, que atribuíam escores as imagens. A análise estatística revelou que a presença ou ausência da superfície radial de apoio (radial land) não interferiu na limpeza das paredes dos canais radiculares. Com relação ao tratamento final, o EDTA a 15% foi capaz de eliminar a \"smear layer\" com maior eficácia, sendo seguido pelo ultra-som e finalmente o laser Er:YAG. Houve diferença estatística significante entre os terços médio e apical dos canais radiculares. / This study evaluated, in vitro, smear layer removal in apical and middle root thirds after instrumentation with four different rotary Ni-Ti instruments and the use of Er:YAG laser, ultrasonic or EDTA. Nineth six mandibular incisors root canals were instrumented with Free Tip Technique, and irrigated with 10 ml of sodium hypochlorite. In Group 1, 24 teeth were instrumented and irrigated only with 10 ml of 2.5 % sodium hypochlorite. Group 24, instrumented as group 1 and irradiated laser Er:YAG in the following parameters: 30/28 fiber optic tip, 42 J, 15Hz and 250mJ input (140mJ output), with the tip activated at the apex and removed to the canal entrance in a helicoidal moviment. Group 3, instrumented as in group 1 and associated with ultrasonic. Group 4, instrumented as in group 1 and associated with with 15% EDTA. Electronic Microscope images were evaluated showed that group 4 had significantly less smear layer (p<0,05) than the group 1 and 2, with group 3 in intermediated position. We conclude that sodium hypochlorite associated with 15% EDTA lead to root canals with less smear layer. The middle third present less smear layer than apical third.
43

Prevalence and determinants of sputum smear non-conversion in smear positive tuberculosis patients at Ephraim Mogale Municipality, Limpopo Province, South Africa

Radingoana, Sylvia January 2017 (has links)
Thesis (MPH.) -- University of Limpopo, 2017. / The present study presents data about the prevalence and determinants of sputum smear non-conversion in smear positive tuberculosis patients. Despite the intervention by the Sekhukhune District Department of Health through continual training and workshops of professional nurses in respect of the NTCP, there are still more challenges observed in terms of TB management. Aim: To investigate the prevalence and determinants of sputum smear non-conversion in smear positive PTB patients after intensive phase of treatment. Method: Quantitative, descriptive retrospective study of TB records was conducted. Data collection was done by extracting data from ETR.net and exporting it to excel. Data cleaning was done before analysis. Data analysis was done using the computer Statistical Package Software for Social research (SPSS) volume 23.1. Findings: 834 TB patients’ records were extracted from the ETR.net database. 34% of records were available at 2 – months; 57% of the patients were males; also, 81% of the patients were diagnosed/treated at PHC facilities; 52% of the patients were HIV positive; 69% percent of the patients who were smear positive grading p+++ failed to convert after two months. In the univariate logistic regression patients with age 20 – 29 were observed to be 4.9 times likely (O.R. = 4.97) to be sputum positive (P = 0.142).Sputum grade 3(p+++) at the time of diagnosis was found to be significantly associated (P = 0.031) with sputum non – conversion after intensive phase of treatment. Conclusion: Two month sputum smear non-conversion is associated with pre-treatment sputum smear grading.
44

The association of socioeconomic status with cervical cancer risk misperceptions, Pap smear screening adherence and cervical outcomes among Ohio Appalachian women

Bernardo, Brittany Marie January 2020 (has links)
No description available.
45

Avaliação dos efeitos da irrigação ultrassônica passiva, por meio de microtomografia computadorizada, microscopia óptica e microscopia eletrônica de varredura / Evaluation of the effect of passive ultrasonic irrigation using computed microtomography, optical microscopy and scanning electron microscopy

Bem, Samuel Henrique Camara de 09 May 2016 (has links)
O presente trabalho teve como objetivo determinar, por meio de microtomografia computadorizada (&mu;CT), o aumento de volume interno, após realização da irrigação ultrassônica passiva (P.U.I.), em diferentes substratos (dentes humanos e bovinos); a remoção da camada de &ldquo;smear&rdquo; e &ldquo;debris&rdquo; do canal radicular, após a realização da P.U.I., com diferentes soluções irrigadoras finais, por meio de microscopia eletrônica de varredura (MEV) e microscopia óptica (MO). Para a verificação do aumento de volume interno vinte dentes (dez humanos e dez bovinos) foram selecionados e padronizados em 17 mm ± 1 mm de comprimento. Os dentes humanos foram preparados até o diâmetro final # 50/05, os dentes bovinos por possuírem canais amplos não receberam preparo biomecânico. Cada dente foi fixado na base da mesa giratória do aparelho de &mu;CT e realizou-se o primeiro exame &mu;CT. Os espécimes foram então submetidos a P.U.I. (aparelho EMS em frequência de 32 KHz) e em seguida foi realizado o segundo exame de &mu;CT respeitando os mesmos padrões do primeiro exame. As imagens capturadas foram comparadas antes e depois da P.U.I. Para a verificação, da remoção da camada de &ldquo;smear&rdquo; e &ldquo;debris&rdquo;, foram selecionados 46 caninos inferiores. Os dentes foram preparados até o diâmetro final # 50/05 e submetidos a P.U.I. com diferentes soluções irrigadoras finais: G3 (Soro fisiológico); G4 (NaOCl 1 %); G5 (EDTA-C 17 %); G6 (NaOCl 1 % / EDTA-C 17 %). Após a P.U.I. vinte e quatro dentes foram preparados e analisados em MEV e vinte e dois dentes foram submetidos ao processamento histológico e analisados em MO. A presença da camada de &ldquo;smear&rdquo; foi determinada a partir da atribuição de escores que variaram de 1 - 4. A presença de &ldquo;debris&rdquo; foi determinada a partir da grade de integração do software Image J. Os dados obtidos foram analisados com auxílio do software BioEstat 5.0. Os resultados mostraram que a P.U.I. aumentou significativamente o volume interno do canal radicular nos dentes humanos (p=0,008) e bovinos (p=0,002). A P.U.I. não removeu a camada de &ldquo;smear&rdquo;; e não removeu &ldquo;debris&rdquo; (p=0,1923) de forma estatisticamente significativa. Concluiu-se que a P.U.I. não é passiva, ela promove alteração de volume no canal radicular, aumentando seu volume interno independentemente do substrato testado; não removeu a camada de &ldquo;smear&rdquo;, mas reduziu significativamente o tempo necessário para que a solução quelante final agisse; não promoveu a remoção de &ldquo;debris&rdquo; estatisticamente significativa, mas independentemente da solução irrigadora final, realizar a P.U.I. aumenta qualitativamente a remoção de &ldquo;debris&rdquo; do canal radicular. / The aim of this study was to determine by &mu;CT the internal volume increasing, after using of P.U.I., in different dental substrates (human and bovine); the removal of the smear layer and debris from the root canal, after using P.U.I. with different irrigation solutions, using SEM e OM. In order to verify the internal volume increasing, 20 teeth (ten humans and ten bovine) were selected and standardized with 17 mm ± 1 mm of length. Human teeth were prepared to a final diameter of #50/05. As the bovine teeth presents large root canal, they did not receive biomechanical preparation. Each tooth was fixed on a movable platform on the &mu;CT device and the first test was carried out. The specimens were subjected to P.U.I. (EMS device with 32 KHz of frequency) in order to performed the second &mu;CT test respecting the same standards. Images were captured and compared before and after P.U.I. Fourth six mandibular canine teeth were selected to verify the smear layer and debris removal. The teeth were prepared to the final diameter of #50/05 and subjected to P.U.I. with different irrigation solutions: G3 (Saline); G4 (NaOCl 1 %); G5 (EDTA-C 17 %); G6 (NaOCl 1% / EDTA-C 17 %). After P.U.I. 24 teeth were prepared and analyzed using SEM and 22 teeth were subjected to histological processing and thus analyzed with OM. The present smear layer was determined by score s\' attribution ranging from 1 - 4. Presence of debris was determined by attribution of the screen integration from the Image J software. Data were analyzed with the support of BioEstat 5.0 software. The results showed that P.U.I. significantly increased the internal volume of root canal of human (p=0,008) and bovine teeth (p=0,002). The P.U.I. did not remove the smear layer nor debris (p=0,1923) statistically significant. It was concluded that P.U.I. is not passive, it increases the internal volume of root canal independently of the tested dental substrates; it did not remove the smear layer, but significantly decreased the onset of action of the final solution; it did not promote statistically significant differences regarding the debris removal however independently of the final irrigation solution to carry out P.U.I. increases the root canal debris removal.
46

Análise qualitativa da remoção do magma dentinário do terço apical de raízes curvas após irrigação convencional, sônica e ultrassônica / Qualitative analysis of smear layer removal, in the apical third of curved canals, after sonic, ultrasonic and conventional irrigation

Gonçalves, Luciana Magrin Blank 05 April 2011 (has links)
No presente estudo foi realizado a análise qualitativa da remoção do magma dentinário do terço apical de raízes curvas, quando submetidos a irrigação convencional, irrigação ultrassônica passiva e irrigação sônica. Como corpos de prova, foram utilizados 62 canais mésio-vestibulares com curvatura entre 20° e 40° de molares inferiores. Todos os condutos, após odontometria, foram instrumentados com o sistema rotatório até a lima F2. Destes, dois condutos foram utilizados como controle negativo, e os outros sessenta foram divididos aleatoriamente em três grupos experimentais conforme sua irrigação final: G1- irrigação convencional com seringa e agulha; G2- irrigação ultrassônica passiva; G3- irrigação sônica com sistema EndoActivator®. Em todos os grupos experimentais, foram utilizados 5mL de EDTA 17% por 1 minuto e 5mL de NaOCl 2,5% por 30 segundos. A observação da região apical, após clivagem, foi realizada através de microscopia eletrônica de varredura em aumento de 1000X. Isto posto, as imagens obtidas foram avaliadas por 3 examinadores calibrados pelo sistema de 3 pontos. Da análise dos resultados, pelo teste de Kruskal-Wallis, pode-se observar que os sistemas sônico e ultrassônico removeram significativamente o magma dentinário, sem diferença estatística entre os grupos. Quando comparados estes sistemas com a irrigação convencional, ambos mostraram-se mais eficientes, sendo os dois grupos estatisticamente diferentes do grupo convencional. Conclui-se que a irrigação sônica e irrigação ultrassônica passiva apresentam resultados semelhantes, aumentando a remoção do magma dentinário no terço apical de raízes curvas. / The aim of this study is to qualitative evaluate, the smear layer removal in the apical third of curved canals, after sonic, ultrasonic and conventional irrigation. Sixty two mesiobuccal root canals of mandibular molar with curvature degree between 20 and 40 degrees, were shaped with rotary system ProTaper® until file F2, and occasionally divided into three experimental groups (n=20) and one control group (n=2). The control group received no final irrigation after fitting of the master cone. The experimental groups received those final irrigations: G1- conventional irrigation with no agitation of the irrigant; G2- passive ultrasonic irrigation; G3- sonic irrigation with EndoActivator® system. In all groups, a final irrigation with 5mL EDTA 17% for 1 minute and 5mL NaOCl 2,5% for 30 seconds was procedure. Root canals were split longitudinally and subjected to scanning electron microscopy at a magnification of 1000X. The presence of smear layer was evaluated by three calibrated observers using a three-score scale. The differences in smear layer scores between the experimental groups were analyzed with Kruskal-Wallis test. Concerning the activations groups, both removed significantly smear layer, with no statistical significant difference. There were statistical significant differences when comparing this systems with conventional irrigation, the activation systems removed significantly more smear layer. The sonic and ultrasonic irrigation, in a similar way, enhance the removal of the smear layer, in the apical third of curved canals.
47

Características da superfície dentinária e do esfregaço formado por instrumentos abrasivos diamantados: rotatório convencional, CVD rotatório e CVD por ultra-som. Estudo in vitro / Characteristics of the dentinária surface and Smear Layer formed by diamantados abrasive instruments: rotatory conventional, rotatory CVD and CVD for ultrasound. Study in vitro

Macedo, Manoel Roberto de Paula 08 June 2005 (has links)
Recentemente surgiram os instrumentos abrasivos diamantados obtidos pela técnica Chemical Vapor Deposition (CVD) utilizados em ultra -som como uma nova possibilidade na técnica do preparo de cavidade. Tradicionalmente, os preparos cavitários são realizados com instrumentos abrasivos diamantados rotatórios convencionais (IADR) formando uma espessa camada de esfregaço. Com o desenvolvimento dos sistemas adesivos, tornou-se muito importante saber a qualidade e a espessura da camada de esfregaço e a topografia dentinária produzida. Com esse objetivo, foram avaliadas in vitro as características da superfície desgastada e a camada de esfregaço produzida em dentina após serem instrumentadas. Foram preparados 24 corpos de prova (cps) e divididos em 4 grupos (grupo 1 – cps preparados com IADR, grupo 2 – cps preparados com CVD rotatório, grupo 3 - cps preparado com CVD Tangencial por ultra-som e grupo 4 - cps preparados com CVD Impacto por ultra-som). Após os desgastes dentinários descritos, os corpos de prova foram desidratados e devidamente preparados para a observação em MEV. Em análise qualitativa as fotomicrografias realizadas no MEV demonstraram significantes diferenças. Os corpos de prova instrumentados com o sistema rotatório (IADR e CVD rotatório) apresentaram ranhuras com traçado retilíneo e paralelo, maior produção de espessura de esfregaço e maior comprimento de smear plug. Os corpos de prova instrumentados com o sistema ultra-sônico (CVD Tangencial eCVD Impacto) apresentaram padrões de ranhuras e traçados próprios, com menores espessuras de esfregaço e menor comprimento de smear plug. / Abrasive diamond instruments are a recent development, obtained through a technique called Chemical Vapor Deposition (CVD), used in ultrasound as a new possibility in dental cavity preparation. Traditionally, cavity preparations are made with conventional abrasive rotary diamond burs (IADR), forming a thick smear layer. Upon the development of new adhesive systems, it has become very important to know the quality and thickness of the smear layer, as well as the dentin topography produced after preparati on. For this purpose, we conducted an in vitro evaluation of the drilled surface and the smear layer produced in dentin after instrumentation. Twenty-four (24) samples were divided into four (4) groups: (group 1 – samples prepared with IADR, group 2 – samples prepared with rotary CVD, group 3 – samples prepared with Tangential ultrasound -guided CVD, and group 4 – groups prepared with Impact ultrasound-guided CVD). After the dentin drilling described, the samples were dehydrated and adequately prepared for SEM observation. A qualitative analysis conducted by SEM microphotography yielded significant differences. The samples worked with the rotary systems (IADR and rotary CVD) showed straight, parallel grooves, with thicker smear layers and longer smear plugs. The samples submitted to ultrasound-guided drilling (Tangential CVD and Impact CVD) showed distinctive groove and contour patterns, with the lowest smear thicknesses and smear plug lengths.
48

Análise comparativa da irrigação convencional, ultrassônica e sistema EndoSafe na remoção do magma dentinário do terço apical de raízes curvas / Comparative analysis of conventional irrigation, ultrasonic and EndoSafe system in removing the smear layer from the apical third of curved root

Kreling, Thalia Ferreira 02 June 2014 (has links)
O presente estudo teve por objetivo avaliar in vitro a eficiência dos sistemas de irrigação (convencional, ultrassônica e EndoSafe), na remoção do magma dentinário de canais mesiais curvos de molares inferiores, por meio de microscopia eletrônica de varredura. Foram utilizados canais mesiais com curvatura entre 200 e 400, de 47 molares inferiores, preparados com Reciproc (instrumento R25). Destes, dois condutos foram utilizados como controle negativo, e os outros foram divididos aleatoriamente em três grupos experimentais conforme a sua irrigação final: IC irrigação convencional com seringa e agulha; PUI irrigação ultrassônica passiva; EndoSafe irrigação com o sistema EndoSafe. Em todos os grupos foram utilizados 5mL de EDTA e 5mL de NaOCl por 30 segundos cada. A observação da região apical, após clivagem, foi realizada através de microscopia eletrônica de varredura em aumento de 1000X. Posteriormente, as imagens obtidas foram avaliadas por 3 examinadores calibrados pelo sistema de três pontos. Da análise dos resultados, pelo teste de Kruskal-Wallis, pode-se observar que o grupo ultrassônico e o EndoSafe apresentaram melhores resultados quando comparados ao grupo convencional, com diferença estatística entre os grupos (PIU: 40%; EndoSafe: 26,7% e IC: 6,7%; sem magma dentinário). Concluiu-se que a irrigação ultrassônica apresenta melhores resultados em comparação aos outros grupos, aumentando a remoção do magma dentinário no terço apical de raízes curvas. / The present study aimed to evaluate in vitro the efficiency of irrigation systems (conventional, ultrasound and EndoSafe system), on removing the smear layer of curved mesial root canals of mandibular molars by means of scanning electron microscopy to evaluate. Fourty seven mesial canals were used with curvature degree between 200 and 400, and were shaped with rotary system Reciproc (R25 instrument). Two of these were used as negative control, and the others were randomly divided into three groups according to their final irrigation: IC - irrigation with conventional syringe and needle; PUI - passive ultrasonic irrigation; EndoSafe - EndoSafe irrigation system. In all groups, 5mL of EDTA, and 5 mL of NaOCl was used for 30 seconds each. Root canals were split longitudinally and subjected to scanning electron microscopic at a magnification of 1000X. The presence of smear layer was evaluated by three calibrated observers using a three-score scale. Analyzing the results, using Kruskal-Wallis test, it could be observed that ultrasonic group and EndoSafe system showed better results when compared to the conventional group, statistical significance between groups (PIU: 40%; EndoSafe: 26.7% and CI: 6.7%; without smear layer). It was concluded that ultrasonic irrigation performs better compared to the other groups, increasing the removal of the smear layer in the apical third of curved roots.
49

Avaliação do cloridrato de tetraciclina na remoção da "smear layer" radicular, em diferentes concentrações, tempos e modos de aplicação. Análise através de microscopia eletrônica de varredura /

Mata, Ana Carolina da. January 2002 (has links)
Orientador: José Eduardo Cezar Sampaio / Banca: Benedicto Egbert Corrêa de Toledo / Banca: Marcio Fernando de Moraes Grisi / Resumo: O objetivo deste trabalho foi avaliar, in vitro, a capacidade do cloridrato de tetraciclina, na remoção da "smear layer" radicular formada após raspagem e aplainamento, em diferentes concentrações, tempos e modos de aplicação. Amostras foram obtidas das superfícies radiculares de dentes extraídos de humanos, sendo submetidos à instrumentação rotatória e raspagem e aplainamento radicular previamente a aplicação do agente condicionante. O cloridrato de tetraciclina foi aplicado por contato ou por fricção com bolinhas de algodão trocadas a cada 30 segundos, em diferentes concentrações: 50, 125, 250 e 500 mg/ml e em diferentes intervalos: 1, 2 e 3 minutos. O grupo controle consistiu de aplicação de soro fisiológico nos mesmos modos e tempos dos grupos testes. Concluímos que: -as concentrações de 125 e 250 mg/ml de tetraciclina foram as que apresentaram os melhores resultados na remoção da "smear layer"; - a aplicação por fricção mostrou ser mais eficiente na remoção da "smear layer"; - os resultados não foram tempo-dependentes. Quando verificou-se as variáveis conjugadas, a concentração de 50 mg/ml sob fricção por 1 minuto e a concentração de 125 mg/ml sob fricção por 1 minuto foram as que apresentaram os melhores resultados. / Abstract: The goal of this study is to assess the capacity of tetracycline HCl in removing -in vitro, in different concentrations, during different intervals and according to different modes of application-radicular smear layer resulting from scaling and planing root surfaces of human extracted teeth, which had been, previously, submitted to rotary instrumentation. Cotton pellets, soaked in a solution of tetracycline HCl, in concentrations of 50, 125, 250, or 500mg/ml, were either gently "placed" or "rubbed" on the prepared root surfaces for either one, two or three minutes. Pellets were changed every 30 seconds. The control group consisted of applying physiological serum during the same intervals and according to the same modes of application of those used for the testing-groups. As a conclusion, the strongestly recommended concentrations of tetracycline for removing radicular smear layer were the ones of 125 and 250 mg/ml; that rubbing root surfaces proved to be the most efficient on the removal of radicular smear layer; and that the results reached in the present study were not time-dependent. When all assessment criteria were simultaneously applied, the best results derived not only from rubbing the prepared surfaces in a concentration of 50 mg/ml of tetracycline HCl, during one minute, but also from rubbing them in a concentration of 125 mg/ml of tetracycline HCl, during one minute. / Mestre
50

Creating 3D Smear Frames for Animation

Drury, Matthew R 01 May 2016 (has links)
In the transition between 2D and 3D animation animators tried to be able to replicate all of the styles and techniques in 3D that they utilized in 2D. Motion blur eventually came to replace a popular 2D technique known as a smear frame. A smear frame is much more than a path of motion or a blur though, it has a style that cannot be replicated with such methods. I present a creative project with the intent on creating 3D smear frames in a self-made character rig. In order to achieve this I will be designing, modeling, texturing, rigging, animating, and rendering the character of Champ Champions.

Page generated in 0.1015 seconds