• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 197
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • Tagged with
  • 198
  • 195
  • 98
  • 64
  • 38
  • 32
  • 25
  • 24
  • 24
  • 22
  • 22
  • 20
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Resultados perinatais em gestaÃÃes com centralizaÃÃo de fluxo fetal ao estudo dopplervelocimÃtrico arterial / Perinatais results in gestations with centralization of fetal flow to the arterial dopplervelocimÃtrico study

Rodney Paiva Vasconcelos 11 September 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / avaliar os resultados perinatais em gestaÃÃes com centralizaÃÃo do fluxo fetal ao estudo dopplervelocimÃtrico e identificar os principais fatores prognÃsticos associados com o Ãbito neonatal. MÃtodos: estudo transversal a partir dos prontuÃrios das gestantes com diagnÃstico de centralizaÃÃo do fluxo fetal (CF), diÃstole zero (DZ) ou reversa (DR) acompanhadas no ServiÃo de Medicina Materno-Fetal da Maternidade-Escola Assis Chateaubriand â Universidade Federal do CearÃ. Foram analisadas 143 pacientes com gestaÃÃes Ãnicas, sem anomalias estruturais ou cromossÃmicas, apresentando idade gestacional superior a 22 semanas e com peso fetal igual ou acima de 500 gramas. Construiu-se curva ROC para idade gestacional e peso ao nascer (variÃveis independentes) e Ãbito neonatal (variÃvel dependente). Os resultados perinatais foram avaliados na populaÃÃo geral e em cada grupo (CF, DZ e DR), sendo posteriormente comparados entre si. Para a avaliaÃÃo estatÃstica, utilizou-se os testes: Shapiro-Wilk, Levene, t Student, Mann-Whitney, ANOVA, Kruskal Wallis, Exato de Fisher, Chi-quadrado de Pearson, RegressÃo LogÃstica e Multinomial. Todos foram considerados estatisticamente significantes quando p<0,05. Resultados: a maioria das gestantes (78,3%) apresentou algum distÃrbio hipertensivo associado à gravidez. A gestaÃÃo foi resolvida nas primeiras 24 horas apÃs o diagnÃstico dopplervelocimÃtrico na maioria dos casos (74,8%), sendo a via abdominal utilizada em 96,5% das vezes. No momento do parto, a idade gestacional mÃdia foi 33,6 semanas e o peso foi 1684g. Os recÃm-nascidos foram classificados como pequenos para idade gestacional em 69,6% e necessitaram de internamento em UTI em 63% dos casos. Os Ãndices de mortalidade perinatal para CF, DZ e DR foram, respectivamente, de 11,1, 31,1 e 70,6%. O peso do RN (Ãrea sob a curva ROC 0,934, p=0,000) e idade gestacional ao nascer (Ãrea 0,909, p=0,000) mostraram ser bons preditores de Ãbito neonatal. O ponto de corte calculado para o peso foi 1010g e para a idade gestacional foi 32,5 semanas. A incidÃncia do Ãndice de lÃquido amniÃtico (ILA) diminuÃdo nas gestaÃÃes com desfecho perinatal letal foi 41,2% e naquelas sem letalidade foi 41,3%. ConclusÃes: fetos com diagnÃstico de CF, DZ e DR apresentaram prognÃsticos progressivamente piores e estatisticamente diferentes entre si. A idade gestacional e peso ao nascer mostraram excelente correlaÃÃo com mortalidade neonatal. O ILA nÃo demonstrou associaÃÃo com taxa de letalidade. / evaluate the perinatal results in pregnancies with fetal brain sparing on the Doppler velocimetric study and identify the main prognostic factors associated with neonatal death. Methods: it is a transverse study from the charts of pregnant women with diagnosis of brain sparing, absent or reversed end-diastolic flow in the umbilical artery, followed at the Service of Maternal-Fetal Medicine of Maternidade-Escola Assis Chateaubriand â Universidade Federal do CearÃ. There were analyzed 143 patients with single pregnancies, without structural or chromosomal anomalies, presenting gestational age above 22 weeks and fetal weight equal or above 500 grams. ROC curve was constructed for gestational age and weight at birth (independent variables) and neonatal death (dependent variable). The perinatal results were evaluated on the general population and on each group (brain sparing, absent and reversed end-diastolic flow), later compared with each other. For the statistical analisys it was utilized the tests: Shapiro-Wilk, Levene, t Student, Mann-Whitney, ANOVA, Kruskal Wallis, Fisher, Chi-square, Logistical and Multinomial Regression. All were considered statistically significant when p < 0.05. Results: the majority of pregnant women (78.3%) presented some hypertensive disturb associated to the pregnancy. The pregnancy was resolved in the first 24 hours after Doppler velocimetric diagnosis on most cases (74.8%), being the abdominal access utilized in 96.5% of the times. At the moment of delivery, the average gestational age was 33.6 weeks and the weight was 1684g. The newborns were classified as small for gestational age in 69.6% and needed ICU admission in 63% of the cases. The indexes of perinatal mortality for brain sparing, absent and reversed end-diastolic flow were respectively 11.1, 31.1 and 70.6%. The weight of the newborn (area bellow the ROC curve 0.934, p=0.000) and gestational age at birth (area 0.909, p=0.000) have shown to be good predictors of neonatal death. The cutoff point calculated for the weight was 1010g and for the gestational age was 32.5 weeks. The incidence of diminished amniotic fluid index (AFI) in the pregnancies with lethal perinatal outcome was 41.2% and in those without lethality was 41.3%. Conclusions: fetuses with diagnosis of brain sparing, absent and reversed end-diastolic flow presented progressively worse and statistically different with each other prognosis. The gestational age and weight at birth showed excellent correlation with neonatal mortality. The AFI did not demonstrate association with lethality rate.
122

AvaliaÃÃo da eficÃcia da ultra-sonografia anorretal tridimensional dinÃmica no diagnÃstico de animus em mulheres com evacuaÃÃo obstruÃda comparando com a eletromanometria anorretal / Evaluation of the dynamic three-dimensional anorectal ultra-sonography effectiveness in animus assessment in women with obstructed defecation comparing with anorectal manometry

Doryane Maria dos Reis Lima 19 December 2006 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Aproximadamente metade dos pacientes constipados apresenta sintomas de evacuaÃÃo obstruÃda, sendo o anismus uma das principais causas. O objetivo à demonstrar uma nova tÃcnica utilizando a ultra-sonografia anorretal tridimensional dinÃmica (USD-3D) para o diagnÃstico do anismus e comparando os resultados com a eletromanometria anorretal. Foram utilizadas neste estudo prospectivo e comparativo 70 mulheres adultas com sintomas de evacuaÃÃo obstruÃda provenientes do ServiÃo de Coloproctologia do Hospital UniversitÃrio Walter CantÃdio da Universidade Federal do CearÃ, no perÃodo entre maio de 2005 a agosto de 2006. A idade variou de 23-79, na mÃdia de 48.72 anos. Todas as pacientes foram inicialmente submetidas à eletromanometria anorretal e, a partir dos resultados, divididas em grupo I, constituÃdo por 40 pacientes normais apresentando relaxamento da musculatura esfincteriana estriada ao esforÃo evacuatÃrio e grupo II com as 30 pacientes restantes com diagnÃstico de anismus. Em seguida, as pacientes de ambos os grupos foram submetidas à ultra-sonografia anorretal tridimensional dinÃmica. A tÃcnica consistiu em dois escaneamentos e as imagens estÃticas e dinÃmicas foram devidamente analisadas nos planos axial e longitudinal, observando-se as posiÃÃes do mÃsculo PR entre o repouso e o esforÃo evacuatÃrio. Visando quantificar de forma objetiva os movimentos do mÃsculo PR, foi desenvolvido no plano longitudinal mediano um Ãngulo constituÃdo por uma linha traÃada paralela à borda interna do PR ( 1.5cm ) com uma outra linha vertical, longitudinal ao eixo do canal anal. Esse Ãngulo à calculado no repouso e no esforÃo evacuatÃrio, sendo a mÃdia no repouso de 88.37   4.05 no grupo I e de 89.13   5.73 no grupo II. NÃo houve diferenÃa significativa entre os dois grupos no repouso ( p=0.51 ). A mÃdia do Ãngulo no esforÃo evacuatÃrio no grupo I foi de 98.19   1.18 e no grupo II, de 84.94   1.31, ocorrendo diferenÃa estatisticamente significante entre os dois grupos ( p<0.001 ). A ultra-sonografia anorretal tridimensional dinÃmica demonstrou resultados concordantes com a eletromanometria anorretal em 92,86 % com relaÃÃo ao diagnÃstico de anismus em pacientes com sintomas de evacuaÃÃo obstruÃda. Conclui-se que a tÃcnica de ultra-sonografia anorretal dinÃmica apresentada neste estudo pode ser considerada eficaz no diagnÃstico do anismus e com a vantagem de demonstrar simultaneamente a conformaÃÃo anatÃmica dos mÃsculos esfincterianos. . / Aproximadamente metade dos pacientes constipados apresenta sintomas de evacuaÃÃo obstruÃda, sendo o anismus uma das principais causas. O objetivo à demonstrar uma nova tÃcnica utilizando a ultra-sonografia anorretal tridimensional dinÃmica (USD-3D) para o diagnÃstico do anismus e comparando os resultados com a eletromanometria anorretal. Foram utilizadas neste estudo prospectivo e comparativo 70 mulheres adultas com sintomas de evacuaÃÃo obstruÃda provenientes do ServiÃo de Coloproctologia do Hospital UniversitÃrio Walter CantÃdio da Universidade Federal do CearÃ, no perÃodo entre maio de 2005 a agosto de 2006. A idade variou de 23-79, na mÃdia de 48.72 anos. Todas as pacientes foram inicialmente submetidas à eletromanometria anorretal e, a partir dos resultados, divididas em grupo I, constituÃdo por 40 pacientes normais apresentando relaxamento da musculatura esfincteriana estriada ao esforÃo evacuatÃrio e grupo II com as 30 pacientes restantes com diagnÃstico de anismus. Em seguida, as pacientes de ambos os grupos foram submetidas à ultra-sonografia anorretal tridimensional dinÃmica. A tÃcnica consistiu em dois escaneamentos e as imagens estÃticas e dinÃmicas foram devidamente analisadas nos planos axial e longitudinal, observando-se as posiÃÃes do mÃsculo PR entre o repouso e o esforÃo evacuatÃrio. Visando quantificar de forma objetiva os movimentos do mÃsculo PR, foi desenvolvido no plano longitudinal mediano um Ãngulo constituÃdo por uma linha traÃada paralela à borda interna do PR ( 1.5cm ) com uma outra linha vertical, longitudinal ao eixo do canal anal. Esse Ãngulo à calculado no repouso e no esforÃo evacuatÃrio, sendo a mÃdia no repouso de 88.37   4.05 no grupo I e de 89.13   5.73 no grupo II. NÃo houve diferenÃa significativa entre os dois grupos no repouso ( p=0.51 ). A mÃdia do Ãngulo no esforÃo evacuatÃrio no grupo I foi de 98.19   1.18 e no grupo II, de 84.94   1.31, ocorrendo diferenÃa estatisticamente significante entre os dois grupos ( p<0.001 ). A ultra-sonografia anorretal tridimensional dinÃmica demonstrou resultados concordantes com a eletromanometria anorretal em 92,86 % com relaÃÃo ao diagnÃstico de anismus em pacientes com sintomas de evacuaÃÃo obstruÃda. Conclui-se que a tÃcnica de ultra-sonografia anorretal dinÃmica apresentada neste estudo pode ser considerada eficaz no diagnÃstico do anismus e com a vantagem de demonstrar simultaneamente a conformaÃÃo anatÃmica dos mÃsculos esfincterianos. . / Aproximadamente metade dos pacientes constipados apresenta sintomas de evacuaÃÃo obstruÃda, sendo o anismus uma das principais causas. O objetivo à demonstrar uma nova tÃcnica utilizando a ultra-sonografia anorretal tridimensional dinÃmica (USD-3D) para o diagnÃstico do anismus e comparando os resultados com a eletromanometria anorretal. Foram utilizadas neste estudo prospectivo e comparativo 70 mulheres adultas com sintomas de evacuaÃÃo obstruÃda provenientes do ServiÃo de Coloproctologia do Hospital UniversitÃrio Walter CantÃdio da Universidade Federal do CearÃ, no perÃodo entre maio de 2005 a agosto de 2006. A idade variou de 23-79, na mÃdia de 48.72 anos. Todas as pacientes foram inicialmente submetidas à eletromanometria anorretal e, a partir dos resultados, divididas em grupo I, constituÃdo por 40 pacientes normais apresentando relaxamento da musculatura esfincteriana estriada ao esforÃo evacuatÃrio e grupo II com as 30 pacientes restantes com diagnÃstico de anismus. Em seguida, as pacientes de ambos os grupos foram submetidas à ultra-sonografia anorretal tridimensional dinÃmica. A tÃcnica consistiu em dois escaneamentos e as imagens estÃticas e dinÃmicas foram devidamente analisadas nos planos axial e longitudinal, observando-se as posiÃÃes do mÃsculo PR entre o repouso e o esforÃo evacuatÃrio. Visando quantificar de forma objetiva os movimentos do mÃsculo PR, foi desenvolvido no plano longitudinal mediano um Ãngulo constituÃdo por uma linha traÃada paralela à borda interna do PR ( 1.5cm ) com uma outra linha vertical, longitudinal ao eixo do canal anal. Esse Ãngulo à calculado no repouso e no esforÃo evacuatÃrio, sendo a mÃdia no repouso de 88.37   4.05 no grupo I e de 89.13   5.73 no grupo II. NÃo houve diferenÃa significativa entre os dois grupos no repouso ( p=0.51 ). A mÃdia do Ãngulo no esforÃo evacuatÃrio no grupo I foi de 98.19   1.18 e no grupo II, de 84.94   1.31, ocorrendo diferenÃa estatisticamente significante entre os dois grupos ( p<0.001 ). A ultra-sonografia anorretal tridimensional dinÃmica demonstrou resultados concordantes com a eletromanometria anorretal em 92,86 % com relaÃÃo ao diagnÃstico de anismus em pacientes com sintomas de evacuaÃÃo obstruÃda. Conclui-se que a tÃcnica de ultra-sonografia anorretal dinÃmica apresentada neste estudo pode ser considerada eficaz no diagnÃstico do anismus e com a vantagem de demonstrar simultaneamente a conformaÃÃo anatÃmica dos mÃsculos esfincterianos. . / Approximately half of the constipated patients shows symptoms of obstructed defecation and anismus is one of the main causes. The aim of this study is to demonstrate a new technique using dynamic three-dimensional anorectal ultrasonography for diagnosis of anismus and compare the results with anorectal manometry. This prospective and comparative study was carried out by seventy women with symptoms of obstructed defecation selected from the Colorectal Unit of the Walter CantÃdio University Hospital of the Federal University of the CearÃ, between may 2005 and august 2006. The mean age was 48 years old (range 23 â 79). All the patients were initially submitted to anorectal manometry and then, depending on the results, separated into two groups. Group I, consisting of forty patients with normal results and presenting anal striated muscles relaxation during straining and group II with the thirty remaining patients with diagnosis of anismus. Subsequently, the patients from both groups were submitted to dynamic three-dimensional anorectal ultrasonography. The method consisted of two automatic scans at rest and during straining. Then, both images were analyzed in the axial and longitudinal planes in order to identify the PR movements. The technique consisted to determine an angle between a line traced parallel to the internal edge of the PR ( 1.5cm ) with another vertical and perpendicular line with the anal canal axis. This angle is calculated at rest and during straining and the average resting angle size was 88.37   4.05 in group I and 89.13   5.73 in group II, without significant difference between them ( p=0.51 ). The mean angle size during straining was of 98.19   1.18 in group I and 84.94   1.31 in group II, showing significant statistical difference ( p<0.001 ). Thus, the dynamic three-dimensional anorectal ultrasonography showed the same results of the anal manometry in 92.86 % of the patients regarding anismus diagnosis in patients with symptoms of obstructed defecation. As a conclusion, the dynamic ultrasonography technique showed to be considered efficient for anismus diagnosis, with the advantage to simultaneously demonstrate the anatomical conformation of the anal canal. / Approximately half of the constipated patients shows symptoms of obstructed defecation and anismus is one of the main causes. The aim of this study is to demonstrate a new technique using dynamic three-dimensional anorectal ultrasonography for diagnosis of anismus and compare the results with anorectal manometry. This prospective and comparative study was carried out by seventy women with symptoms of obstructed defecation selected from the Colorectal Unit of the Walter CantÃdio University Hospital of the Federal University of the CearÃ, between may 2005 and august 2006. The mean age was 48 years old (range 23 â 79). All the patients were initially submitted to anorectal manometry and then, depending on the results, separated into two groups. Group I, consisting of forty patients with normal results and presenting anal striated muscles relaxation during straining and group II with the thirty remaining patients with diagnosis of anismus. Subsequently, the patients from both groups were submitted to dynamic three-dimensional anorectal ultrasonography. The method consisted of two automatic scans at rest and during straining. Then, both images were analyzed in the axial and longitudinal planes in order to identify the PR movements. The technique consisted to determine an angle between a line traced parallel to the internal edge of the PR ( 1.5cm ) with another vertical and perpendicular line with the anal canal axis. This angle is calculated at rest and during straining and the average resting angle size was 88.37   4.05 in group I and 89.13   5.73 in group II, without significant difference between them ( p=0.51 ). The mean angle size during straining was of 98.19   1.18 in group I and 84.94   1.31 in group II, showing significant statistical difference ( p<0.001 ). Thus, the dynamic three-dimensional anorectal ultrasonography showed the same results of the anal manometry in 92.86 % of the patients regarding anismus diagnosis in patients with symptoms of obstructed defecation. As a conclusion, the dynamic ultrasonography technique showed to be considered efficient for anismus diagnosis, with the advantage to simultaneously demonstrate the anatomical conformation of the anal canal. / Approximately half of the constipated patients shows symptoms of obstructed defecation and anismus is one of the main causes. The aim of this study is to demonstrate a new technique using dynamic three-dimensional anorectal ultrasonography for diagnosis of anismus and compare the results with anorectal manometry. This prospective and comparative study was carried out by seventy women with symptoms of obstructed defecation selected from the Colorectal Unit of the Walter CantÃdio University Hospital of the Federal University of the CearÃ, between may 2005 and august 2006. The mean age was 48 years old (range 23 â 79). All the patients were initially submitted to anorectal manometry and then, depending on the results, separated into two groups. Group I, consisting of forty patients with normal results and presenting anal striated muscles relaxation during straining and group II with the thirty remaining patients with diagnosis of anismus. Subsequently, the patients from both groups were submitted to dynamic three-dimensional anorectal ultrasonography. The method consisted of two automatic scans at rest and during straining. Then, both images were analyzed in the axial and longitudinal planes in order to identify the PR movements. The technique consisted to determine an angle between a line traced parallel to the internal edge of the PR ( 1.5cm ) with another vertical and perpendicular line with the anal canal axis. This angle is calculated at rest and during straining and the average resting angle size was 88.37   4.05 in group I and 89.13   5.73 in group II, without significant difference between them ( p=0.51 ). The mean angle size during straining was of 98.19   1.18 in group I and 84.94   1.31 in group II, showing significant statistical difference ( p<0.001 ). Thus, the dynamic three-dimensional anorectal ultrasonography showed the same results of the anal manometry in 92.86 % of the patients regarding anismus diagnosis in patients with symptoms of obstructed defecation. As a conclusion, the dynamic ultrasonography technique showed to be considered efficient for anismus diagnosis, with the advantage to simultaneously demonstrate the anatomical conformation of the anal canal.
123

Estimativas de parâmetros genéticos de características de carcaças feitas por ultra-sonografia em bovinos da raça Nelore / Genetic parameters for carcass traits measured trough ultrasound in Nelore cattle

Luís Gustavo Girardi Figueiredo 24 May 2001 (has links)
O presente trabalho teve como objetivo estimar parâmetros genéticos de características de carcaças feitas por ultra-sonografia em bovinos da raça Nelore bem como as suas correlações genéticas com características de desenvolvimento ponderal e com escores visuais. Os dados coletados pertencem a três fazendas, duas pertencentes a Agropecuária CFM (Rebanho 1) que foram analisadas em conjunto com 1696 animais e uma pertencente a Manah Agropastoril Ltda. com 951 animais (rebanho 2). As características analisadas foram: área de olho de lombo (AOL), espessura de gordura subcutânea (EGS), peso a desmama (PESDES), ganho de peso da esmama ao sobreano (GP345), peso ao sobreano (PESSOB) e altura (ALT). E os escores visuais analisados foram: musculosidade (MUSC), conformação (CONF) e precocidade (PREC). Os componentes de (co)variância foram estimados por verossimilhança restrita, utilizando-se o software MTDFREML. Foram realizadas análises uni-características em que foram estimadas as herdabilidades das características AOL e EGS e análises bi-características em que foram estimadas as correlações genéticas das características de AOL e EGS com as características de desempenho ponderal e escores visuais. As estimativas herdabilidades para AOL foram de 0,19 (rebanho 1) e de 0,41 (rebanho 2), para a EGS foram de 0,04 (rebanho 1) e de 0,19 (rebanho 2). Estas herdabilidades sugerem que as características são passíveis de seleção. São sugeridos estudos adicionais de estimativas de componentes de (co)variância para medidas de ultra-sonografia para bovinos da raça Nelore. / This research was conducted to estimate variance components and genetic parameters of carcass traits of Nelore cattle, measured through ultrasound equipment, and also the genetic relationship of those traits with growth traits and visual scores. Data came from three different herds. 1,696 animals were measured in two farms owned by Agro-Pecuaria CFM Ltda. (herd 1) and 951 animals were measured at Fazenda Mundo Novo, owned by Manah Agropastoril Ltda. (herd 2). The traits analyzed were: loin-eye are (AOL, cm2), subcutaneous fat thickness (EGS, mm), weaning weight (PESDES, kg), weight gain from weaning to yearling (GP345, kg), yearling weight (PESSOB, kg), and height (ALT, cm). Visual scores were muscle score (MUSC), body conformation (CONF) e precocity (PREC). (Co)variance components were estimated by REML methods, using the software MTDFREML, under single traits (to estimate components for AOL and EGS) and twotraits analysis to estimate genetic correlations among AOL and EGS and the other traits. Heritability estimates for AOL were 0.19 (herd 1) and 0.41 (herd 2). While for EGS the values estimated were 0.04 (herd 1) and 0.19 (herd 2). The heritability coefficients estimated suggest that the traits can be selected. Further studies are suggested as related to (co)variance components estimation for ultrasound measurements in Nelore cattle.
124

Análise da vascularização da mandíbula edêntula pós-fratura: estudo por ultra-som doppler colorido / Analysis of the blood supply to post-fracture edentulous mandible. Study by color Doppler ultrasonography

Julio Cezar Marques Assad Mancini 25 March 2008 (has links)
O tratamento das fraturas de mandíbulas edêntulas é motivo de controvérsias na literatura e um dos fatores que tornam seu tratamento complexo é o suprimento sanguíneo reduzido. Nesse contexto, o ultra-som Doppler consiste em exame nãoinvasivo o qual pode ser utilizado na análise de alterações da vascularização de diversos segmentos corpóreos e influenciar decisões clínicas. Este trabalho teve como objetivo avaliar a vascularização mandibular de pacientes edêntulos que foram submetidos a tratamento de fratura de mandíbula (grupo experimental), por meio de ultra-som doppler colorido. Possíveis correlações entre os dados clínicos, radiográficos e a vascularização mandibular foram analisadas. O fluxo arterial de vasos, como carótida externa, maxilar, facial, mentual, submentual e sublingual, após o tratamento, foi comparado ao fluxo arterial dos mesmos vasos em um grupo controle composto por pacientes edêntulos livres de fratura. Com o emprego do transdutor linear, de maneira extra-oral, foram obtidos velocidade pico-sistólica (VPS), velocidade diastólica final (VDF), índice de resistência (IR), índice de pulsatilidade (IP) e aceleração, de cada artéria. Além disso, foram obtidos detalhes do tratamento por meio de avaliação clínica e radiográfica, assim como da avaliação dos prontuários. Houve diferenças estatisticamente significantes para os valores de IR da artéria mentual, IP da artéria maxilar, VPS, IP e aceleração da artéria submentual. Além disso, na pesquisa de fatores vasculares locais obstrutivos, de acordo com a artéria e os fatores estudados, houve diferenças estatisticamente significantes para o VPS, VDF e IP da artéria facial, IR da artéria sublingual, os quais apresentaram valores menores quando da presença desses fatores. Os grupos experimental e controle foram semelhantes quanto à ocorrência de variações de sentido de fluxo. Na análise das correlações entre os fatores estudados e o grau de atrofia alveolar, foram observadas diferenças estatisticamente significantes para os valores de VPS e VDF da artéria submentual, maiores no grupo não-atrófico. O exame de ultra-som doppler colorido foi capaz de demonstrar alterações em algumas artérias que suprem a mandíbula de pacientes edêntulos submetidos a tratamento de fratura, havendo poucas correlações com o grau de atrofia alveolar. / The treatment of edentulous mandibular fractures is motive of controversies in literature and one of the factors that make this treatment complex is the reduced blood supply. In this context, the doppler ultrasound is a non-invasive method that can be used in the analysis of changes in the vascularization of several corporeous segments and influence clinical decisions. The purpose of this study is to assess the vascular supply of edentulous patients, that have been treated of mandibluar fracture (experimental group), using the colored Doppler ultrasound. Possible correlations between the alveolar atrophy degree and the mandibular blood supply were analyzed. The arterial flow of vessels like external carotid, maxilar, facial, mentual, submentual and sublingual, after treatment, was compared with the arterial flow of the same vessels in a control group, consisting of edentulous fracture-free patients. With the use of linear probe extra-orally, the systolic-peak maximum velocity (SPV), final diastolic velocity (FDV), resistive index (RI), pulsatility index (PI) and acceleration of each artery, was obtained. Also, treatment details were obtained through clinical, radiological investigations, and hospital notes assessments. There was significant statistic differences to the values mentual artery RI, maxilar artery PI, submentual artery SPV, PI and acceleration. Also, in the analysis of the presence of obstructive vascular local factors, according to the artery and studied factors, statistically significant differences were observed to facial artery SPV, FDV and PI, sublingual artery RI, that present lower values when these factors were present. The experimental and control groups were similar in respect to variations in flow direction occurrence. In the analysis of the correlations between the studied factors and alveolar atrophy degree, statistically significant differences were observed to the submentual artery SPV and FDV, higher in non-atrophic group. The color doppler sonography was able to show changes in some arteries that supply the mandible of edentulous patients submitted to fracture treatment, with few correlations with the alveolar atrophy degree.
125

Contribuição da ultra-sonografia para o diagnóstico das alterações histopatológicas presentes na hepatite C crônica, com ênfase na esteatose hepática / Ultrasonographic contribution for the diagnosis of the histopathological alterations in chronic hepatitis C, with emphasis in hepatic steatosis

Marcia Wang Matsuoka 15 May 2008 (has links)
INTRODUÇÃO: A utilização da ultra-sonografia (USG) como método de diagnóstico por imagem na avaliação das afecções abdominais, em particular para o acompanhamento de pacientes portadores de hepatite C crônica, vem sendo rotineiramente empregada. Neste trabalho, avaliamos a contribuição da USG na avaliação das alterações histopatológicas encontradas neste grupo de doentes, com ênfase para a esteatose hepática (EH), afecção bastante freqüente na hepatite causada pelo vírus C. MÉTODO: Comparamos os achados ultra-sonográficos de 192 pacientes consecutivos, portadores de hepatite crônica pelo vírus C, submetidos à biópsia hepática, com os achados histopatológicos dos fragmentos hepáticos obtidos. Todos os pacientes foram biopsiados sob orientação USG, sendo a ultra-sonografia assim como a biópsia hepática realizadas cada qual por um médico especialista e sempre o mesmo. Todos os exames ultra-sonográficos obedeceram a um mesmo protocolo, sendo analisados os seguintes parâmetros ultra-sonográficos: 1) com relação às características ecográficas do parênquima: ecogenicidade, ecotextura e atenuação; 2) com relação à utilização da USG para o diagnóstico da EH: biometria da parede abdominal, dimensões e contornos hepáticos. Posteriormente os pacientes estudados foram agrupados em: A) grupo com alterações ultra-sonográficas e B) sem alterações ultra-sonográficas, e comparados com as alterações histopatológicas presentes. Foram realizados também cálculos de regressão logística com os parâmetros USG avaliados para a avaliação da acurácia deste método de imagem para o diagnóstico da EH. RESULTADOS: Entre as alterações histopatológicas presentes, a alteração arquitetural e a EH apresentaram diferença estatística significante entre os grupos A (com alterações USG) e B (sem alterações USG). Observou-se também diferença estatística significante entre: a) espessura da parede abdominal e as dimensões hepáticas com relação à presença de EH, b) contornos hepáticos irregulares e a presença de EH. E dentre os componentes ultra-sonográficos avaliados, a atenuação foi o que apresentou melhor correlação com a EH. A utilização das variáveis idade, sexo, atenuação, espessura da parede abdominal e dimensões hepáticas, foram as que apresentaram melhores resultados nos cálculos de regressão logística, com sensibilidade de 60,5% e especificidade de 83,9% em diagnosticar EH. CONCLUSÕES: Neste trabalho, o estudo ultra-sonográfico do fígado de pacientes com hepatite C crônica apresentou correlação com as alterações arquiteturais e com a EH encontradas na histopatologia. A utilização da USG para o diagnóstico da EH apresentou relação estatística com a espessura da parede abdominal, dimensões e contornos hepáticos, e a atenuação foi o melhor componente ultra-sonográfico para o diagnóstico da EH. / INTRODUCTION: Ultrasonography is consistently utilized as the method of diagnostic imaging while evaluating abdominal infections particularly in patients with chronic hepatitis C. We studied the contribution of the ultrasonography in the evaluation of histopathologic alterations in this group of patients with emphasis in hepatic steatosis (HS), sufficiently frequent in hepatitis caused by the C virus. METHODS: We compared the findings from the ultrasounds of 192 carrying patients of chronic hepatitis C virus, who had undergone hepatic biopsy, with the histopathogical findings of the hepatic fragments obtained. All patients who have undergone liver biopsy guided by ultrasonography were always evaluated by the same medical specialist for both sonogram or hepatic biopsy. All ultrasound examinations followed the same protocol, analyzing the following parameters: 1) regarding to the echographic characteristics of parenchyma: echogenicity, echotexture and attenuation; 2) regarding to the use of the sonography for the diagnosis of the HS: biometry of the abdominal wall, hepatic dimensions and contours. Post results, patients had been grouped in: A) altered ultrasound group and B) ultrasound group without ultrasound alterations, both compared with present histopathological alterations. Calculations of logistic regression with ultrasonography parameters had also been performed to determine the accuracy of this method for the HS diagnosis. RESULTS: Of the histopathological alterations present, the architectural alteration and the HS had presented significant statistical difference between the groups (altered ultrasound group) and the B (without ultrasound alterations). We also noted significant statistical difference between: a) thickness of the abdominal wall and the hepatic dimensions with regard to presence of HS, b) irregular hepatic contours and the presence of HS. Amongst the evaluated ultrasound components, attenuation presented better correlation with the HS. The variables age, sex, attenuation, thickness of the abdominal wall and hepatic dimensions of the right lobe, presented better results in the calculations of logistic regression, with 60,5% sensitivity and specificity of 83,9% in diagnosing HS. CONCLUSIONS: In this research, the hepatic ultrasonography of patients with chronic hepatitis C presented correlation with the architectural alterations and the HS found at the histopathology. The utilization of the ultrasonography for the diagnosis of the HS presented statistical relationship with the thickness of the abdominal wall, hepatic dimensions and contours, and the sonographic attenuation was the best component for the diagnosis of ES.
126

Alterações seqüenciais da deformação miocárdica longitudinal e radial (strain/strain rate) e das velocidades do Doppler tecidual pulsado em neonatos normais / Sequential changes of longitudinal and radial deformation (strain/strain rate) and pulsed wave tissue Doppler in normal neonates

José Luiz Barros Pena 20 January 2006 (has links)
Introdução: O Doppler tecidual (DT) surgiu como uma técnica ecocardiográfica para registro das velocidades do miocárdio e evoluiu para a determinação da deformação miocárdica regional com medida do strain rate (SR) e strain longitudinal e radial unidimensionais. Nosso objetivo foi determinar padrões de normalidade em neonatos e analisar seqüencialmente esses índices em períodos de alta e baixa resistência vascular pulmonar. Casuística e Método: Selecionaram-se 55 crianças com idade média de 20,14 ± 14,0 horas, constituindo o Grupo I (G I). Um segundo exame foi realizado em 30 crianças que retornaram após 31,9 ± 2,9 dias de vida, constituindo o Grupo II (G II). As velocidades do DT pulsado foram obtidas em cortes transversais (R) e longitudinais (L) do ventrículo esquerdo (VE) em posições apical 4 e 2 câmaras e no VD (paredes livre e inferior). Foram medidas velocidades sistólicas (onda Sm), diastólica inicial (Em), diastólica final (Am) de pico e a relação Em/Am. Pelo menos três ciclos cardíacos consecutivos com taxa de quadros/s superior a 300 foram digitalmente obtidos nos cortes mencionados e analisados posteriormente utilizando programa específico para medida das curvas de SR/strain e seus componentes sistólico, diastólico inicial e final. Resultados: As velocidades demonstraram gradiente bem definido com redução progressiva na direção base-ápice do coração. As velocidades do VD foram superiores às do VE quando comparadas com as medidas nas paredes septal (S), anterior (A) e lateral (L). No GI verificamos diferença significativa entre as medidas do SR/strain sistólicos do segmento basal da parede S em relação à apical (-1,90 ± 0,61, - 25,90 ± 4,90 vs -1,66 ± 0,25, - 24,23 ± 3,08), p=0,04 e p=0,02 e do segmento médio em relação ao apical (p=0,01 e 0,02). A avaliação regional do VD demonstrou strain sistólico maior no segmento médio em relação ao basal (-33,20 ± 6,34 vs -28,38 ± 4,90, p=0,00) e em relação ao segmento apical (-33,20 ± 6,34 vs -31,95 ± 5,06, p=0,021). Os valores absolutos de SR/strain e todos os seus componentes foram maiores na direção R quando comparados com a L (SR sistólico 2,99 ± 0,78 s-1 vs (-)1,90 ± 0,60 s-1 strain sistólico 49,72% ± 12,86% vs (-) 25,86% ± 4,83 p=0,00). Quando comparamos os GI e GII verificamos redução do strain sistólico do VE na direção R e L nas paredes S, L e A em todos os segmentos. O SR sistólico reduziu apenas na porção basal da parede L (-1,91 ± 0,46 s-1 vs - 1,71 ± 0,33 s-1, p=0,02). O VD apresentou no GII aumento significativo do strain sistólico e diastólico inicial em todos os segmentos e paredes. O SR sistólico também apresentou aumento dos valores nos segmentos basal e médio de sua parede livre e na parede inferior. A correlação entre a onda Sm e SR/strain sistólicos não foi significativa. Conclusão: Os índices regionais de deformação miocárdica constituem técnica clínica reproduzível em neonatos e podem monitorar alterações seqüenciais fisiológicas da circulação neonatal precoce e tardia. São mais robustos que as velocidades na quantificação da função regional. / Background: Color Doppler myocardial imaging (CDMI) has emerged as an echocardiographic technique for determining myocardial velocities and has been further developed to allow the determination of one-dimension regional longitudinal and radial strain rate (SR)and strain. Our goal was to determine normal values in neonates and sequentially analyse these indices in periods of high and low pulmonary vascular resistance. Study population and methods: Fifty-five term newborns with mean age of 20.14 ± 14.0 hours were selected to be part of Group I (GI). A second echo study was performed on 30 children that had returned with 31.9 ± 2.9 days after birth, being Group II (GII). Pulsed wave Doppler tissue velocities (PWDTV) were obtained in short axis (R) and longitudinal (L) axis of the left ventricle (LV) in apical 4 and 2 chamber view and in 4 and 2 chamber of the right ventricle (RV), including RV free lateral and inferior walls. Peak systolic (Sm), peak early diastolic (Em) and peak late diastolic (Am) motion velocities and Em/Am ratio were measured. At least three consecutive cardiac cycles with frame rate more than 300 fps were stored in digital format from the mentioned views for offline analysis by using dedicated software for measuring peak systolic and peak early and late diastolic SR/strain. Results: PWTDV have shown a well-defined gradient with progressive peak reduction from base to apex. RV velocities were higher than those of the LV whem compared to septal (S), anterior (A) and lateral (L) walls. In GI there was a significant difference between systolic SR/strain measurement of basal S segment in relation to apical (-1.90 ± 0.61, -25.90 ± 4.90 vs -1.66 ± 0.25, - 24.23 ± 3.08), p=0.04 e p=0.02 and from the mid in relation to the apical segment (p=0.01 e 0.02). Regional RV longitudinal function showed that systolic strain recorded from the mid segment was significantly higher than that recorded from the basal segment (-33.20 ± 6.34 vs -28.38 ± 4.90, p=0.00) and that from the apical segment (-33.20 ± 6.34 vs ?31.95 ± 5.06, p=0.021). The absolute and all components of SR/strain were significantly higher in R direction when compared to the L ones (systolic SR 2.99 ± 0.78 s-1 vs (-)1.90 ± 0.60 s-1 systolic strain 49.72% ± 12.86% vs (-)25.86% ± 4.83 p=0.00). When comparing data from GI and GII, we noticed reduction of LV systolic strain in the second group for both R and L, in all segments of S, L and A walls. Systolic SR showed reduction of the values in GII only in the basal segment of the L wall (-1.91 ± 0.46 s-1 vs ?1.71 ± 0.33s-1, p=0.02). Regional RV function showed systolic and early diastolic strain significantly higher in all segments of wall in GII. Systolic SR also showed higher values in the basal and mid segments of RV free lateral and inferior wall in GII when comparing to GI. The correlation between peak systolic velocity Sm and peak systolic SR/strain was not significant. Conclusion: Regional myocardial deformation indices are reproducible clinical techniques in neonates and can monitor physiological sequential circulatory changes of the early and late neonatal period. They are more robust than velocities in the quantification of the regional myocardial function.
127

Avaliação anatômica de artérias coronárias humanas por ressonância magnética, ultra-som intravascular e anatomia patológica \"in vitro\" / Anatomical evaluation of human coronary arteries by magnetic resonance, intravascular ultrasound and pathological anatomy \"in vitro\"

Gomes, Everli Pinheiro de Souza Gonçalves 15 September 2008 (has links)
INTRODUÇÃO: A avaliação da morfologia das artérias coronárias é objeto de interesse dentro do desenvolvimento de uma melhor qualidade de imagem que possibilite um diagnóstico fidedigno das lesões coronárias. Para isso, estudos com ressonância magnética (RM) e ultra-som intravascular coronário (UIV) tem se desenvolvido na tentativa de mensurar e caracterizar melhor a doença coronária in vivo. OBJETIVO: Determinar a capacidade da ressonância magnética em detectar alterações na luz e na parede das artérias coronárias com aterosclerose, tendo como padrões o ultra-som intracoronário e a anatomia patológica.MÉTODOS: Estudamos 13 corações de pacientes, falecidos por infarto do miocárdio. Os corações foram fixados com solução de formol a 10% sob perfusão com pressão constante de 80 mmHg. Em seguida as artérias coronárias interventricular anterior, direita e circunflexa esquerda foram dissecadas, preservando-se a adventícia e parte da aorta. As seguintes medidas foram feitas: área total do vaso (ATV), área da luz (AL), maior (MaDV) e menor (MeDV) diâmetro do vaso, diâmetro mínimo (DminL) e máximo (DmaxL) da luz do vaso e espessura mínima (EminP) e máxima (EMaxP) da parede pelos seguintes métodos: UIV, RM e anatomia patológica (AP). Foram analisadas 38 artérias, correspondendo a 355 segmentos arteriais. Utilizamos em média os 3 primeiros centímetros de cada artéria, e em cada centímetro foram avaliados 3 segmentos: proximal, médio e distal. As medidas obtidas nos 3 métodos foram comparadas através do teste de correlação de Pearson e método de Bland Altman Plot. As comparações entre os 3 métodos, pelas suas respectivas médias e desvios padrão, foram realizadas pela análise de variância para medidas repetidas.RESULTADOS: As médias das variáveis na RM,UIV e AP foram respectivamente: ATV 15,46 ± 4,83, 13,86 ± 5,20 e 11,87 ± 4,57; MaDV 4,75 ± 0,84, 4,40 ± 0,87 e 4,18 ± 0,87; MeDV 4,23 ± 0,73, 3,75 ± 0,72 e 3,48 ± 0,70; AL 5,59 ± 2,93, 6,86 ± 3,18 e 5,57 ± 2,46; DmiL 2,54 ± 0,64, 2,55 ± 0,57 e 2,32 ± 0,52; DmaxL 3,07 ± 0,65, 3,34 ± 0,76 e 3,04 ± 0,83; EminP 0,76 ± 0,25, 0,38 ± 0,18 e 0,34 ± 0,17; EmaxP 1,11 ± 0,39, 0,88 ± 0,37 e 0,90 ± 0,48. As correlações com maior significância foram: 1. APxRM: ATV e AL (r=0,767 e r=0,805); 2. RMxUIV ATV e AL (r=0,836 e r=0,770); 3. APxUIV ATV e MeDV (r=0,89 e r=0,692). As variáveis que tiveram melhor correlação foram a ATV, MaDV, MeDV e AL nos 3 métodos. A EminP e EmaxP tiveram fraca correlação. As médias das variáveis DminL e DmáxL nos 3 métodos foram muito próximas. Na variável ATV notamos que a média superestimou a medida do vaso. CONCLUSÃO: A RM correlacionou-se com o UIV para a maioria das medidas, em especial: ATV, MaDV, MeDV, AL e DmaxL. As medidas nesses 2 métodos se correlacionaram em menor intensidade com a AP, sendo nesta sempre com valores menores. Assim, a RM pode vir a ser método fidedigno para o diagnóstico e prognóstico na doença aterosclerótica coronariana, na dependência do desenvolvimento tecnológico permitindo maior rapidez na aquisição de imagens / INTRODUCTION: Numerous studies in the area of image have been conducted to evaluate the morphology of the coronary arteries. Major technical advances have provided better image quality that allows a reliable diagnosis of coronary lesions. For this, studies with cardiovascular magnetic resonance (CMR) and coronary intravascular ultrasound has been developed in an attempt to better measure and characterize coronary heart disease \"in vivo\". PURPOSE: To determine the capacity of CMR to detect changes in the lumen and the wall of the coronary arteries caused by atherosclerosis, using as references intravascular ultrasound (IVUS) and pathology measurements. METHODS: We examined 13 hearts of patients that died of myocardial infarction. The hearts were fixed with formalin solution to the 10% with constant pressure of 80 mmHg. Then the left anterior descending (LAD), left circumflex (LCx) and right coronary (RCA) arteries were dissected from the the aorta and epicardial fat and isolated as pathological specimens. The arteries were analyzed by CMR, IVUS and pathology and the images were subjected to analysis of the following parameters: total vessel area (TVA), lumen area (LA), major (MaVD) and minor vessel diameter (MiVD), minor (MiLD) and major lumen diameter (MaLD), minor (MiWT) and major wall thickness (MaWT). We analyzed the entire 355 arterial segments, using at least the first proximal 2 cm, in most cases 3 cm or more of each artery. In every centimeter we measured the parameters of the proximal, mid and distal segments. The measures obtained in the three methods were compared using Pearson correlation and the method of Bland and Altman plot. Comparisons among the three methods, by their respective averages and standard deviations, were carried out by analysis of variance with repeated measures. RESULTS: Measures in CMR,IVUS e PA were as follow respectively: TVA 15.46 ± 4.83, 13.86 ± 5.20 and 11.87 ± 4.57; MaVD 4.75 ± 0.84, 4.40 ± 0.87 and 4.18 ± 0.87; MeVD 4.23 ± 0.73, 3.75 ± 0.72 and 3.48 ± 0.70; LA 5.59 ± 2.93, 6.86 ± 3.18 and 5.57 ± 2.46; MiLD 2.54 ± 0.64, 2.55 ± 0.57 and 2.32 ± 0.52; MaLD 3.07 ± 0.65, 3.34 ± 0.76 and 3.04 ± 0.83; MiWT 0.76 ± 0.25, 0.38 ± 0.18 and 0.34 ± 0.17; MaWT 1.11 ± 0.39, 0.88 ± 0.37 and 0.90 ± 0.48.The best correlations were: 1. PAxCMR: TVA and LA (r=0.767 and r=0.805); 2. CMRxIVUS: TVA and LA (r=0.836 and r=0.770); 3. PAxIVUS: TVA and MiVD (r=0.89 and r=0.692). The variables that have shown the best correlations were TVA, MaVD, MiVD and LA in the 3 methods. The MiWT and MaWT had a weak correlation. The averages of variables MiLD and MaLD in the 3 three methods were very similar. CONCLUSION: CMR correlated well with IVUS for the majority of measures done and in especial for TVA, LA, MaVD, MiVD and MaLD. Measures in both methods had lower correlation with pathology that showed the lower values of all. As a perspective CMR may be a reliable method for measuring coronary artery dimensions, depending on new technical development for faster image acquirer
128

O valor da ultra-sonografia na avaliação do traumatismo abdominal fechado / Value of ultrasound in the evaluation of blunt abdominal trauma

Jayanthi, Shri Krishna 13 March 2008 (has links)
O trauma é uma das principais causas de morbidade e mortalidade em uma faixa etária que compreende adolescentes e adultos jovens, em proporção dominante do sexo masculino, com grande impacto econômico e social. Dentro do complexo do trauma, o traumatismo abdominal fechado (TAF) é um evento bastante freqüente e apresenta dificuldade na avaliação e manejo, uma vez que o exame clínico apresenta baixa sensibilidade e especificidade. A detecção de hemoperitônio é um dos métodos de avaliação indireta de possíveis lesões intra-abdominais, inicialmente pela punção abdominal diagnóstica e posteriormente pela lavagem peritoneal diagnóstica, que, apesar da eficácia, apresentam inconvenientes invasividade e impossibilidade na quantificação do hemoperitônio e no estadiamento da lesão, resultando em laparotomias não-terapêuticas. Os métodos de imagem prestam utilidade na investigação de lesões intra-abdominais, como a radiografia convencional e contrastada, ultra-sonografia (US) e a tomografia computadorizada (TC), esta última o método que apresenta melhor resolutividade, porém como desvantagens o custo, acessibilidade, o uso de radiação ionizante e meio de contraste e o deslocamento do paciente até o aparelho. A US apresenta-se como alternativa na avaliação inicial destes pacientes como método não invasivo e com potencial de dano virtualmente ausente, de baixo custo, de rápida realização e portátil. Apesar disso, este método também apresenta suas limitações, como na de lesões intra-abdominais na ausência de líquido livre. Este estudo foi realizado com a finalidade de estabelecer o desempenho da US neste contexto, permitindo racionalizar o uso da TC. Com essa finalidade foram estudados 163 pacientes atendidos pelo PS-HC/FMUSP, com a realização consecutiva de US e TC. A população estudada enquadra-se no perfil usual das vítimas de trauma, sendo 83% do sexo masculino e 56% na faixa etária entre 20 e 39 anos e em 73% dos casos eram vítimas de acidentes de trânsito. Eles foram trazidos ao serviço num tempo médio de 51 minutos, na maior parte estáveis e com nível de consciência satisfatório. A US levou em média 5 minutos para ser realizada e o intervalo médio até a realização da TC foi de155 minutos. Dos 163 pacientes 31 (19%) apresentaram US positiva e 132 (81%) apresentaram US negativa. Dos mesmos 163 pacientes 33 (20,2%) apresentaram TC positiva e 130 (79,8%) apresentaram TC negativa, resultando em sensibilidade de 73%, especificidade de 95%, acurácia de 90% em prevalência de 20%, com valor preditivo positivo de 77% e valor preditivo negativo de 93%. Corrigindo quanto à detecção de líquido livre, resulta-se em sensibilidade de 64%, especificidade de 98%, acurácia de 89% em prevalência de 27,6% e valor preditivo positivo de 93% e valor preditivo negativo de 88%. Ao se considerar a evolução dos pacientes, o desempenho da US foi semelhante ao da TC. Ao se considerar a necessidade de cirurgia a US apresentou acurácia de 87%, com valor preditivo positivo de 58% e valor preditivo negativo de 94%, próximo da TC, com 91% de acurácia, 67% de valor preditivo positivo e 97% de valor preditivo negativo. 24% dos pacientes com lesões intra-abdominais não apresentavam líquido livre, registrados pela TC. O espaço hepatorrenal e a pelve são os locais mais freqüentes do encontro de líquido, sendo 74% e 67% à US e 51% e 62% à TC, respectivamente. Entre os fatores que indicaram tendência de necessidade cirúrgica destaca-se a presença de líquido no espaço hepatorrenal (14 de 20 pacientes) e somatória dos bolsões de líquido acima de 3,0 cm. A detecção de lesões em víscera parenquimatosa foi baixa: 4 casos em 33, sendo que apenas 2 deles se confirmaram. Dentre os fatores que limitam o estudo pela US estão as lesões intraparenquimatosas que não se associam a líquido livre e hematomas retroperitoneais. A experiência do examinador não influenciou no número de casos positivos ou negativos, mas notou-se uma tendência a falso-positivos em examinadores mais experientes e falso-negativos em menos experientes. Assim, a US apresenta-se como ferramenta útil na avaliação inicial de traumatismo abdominal fechado, fornecendo subsídios para avaliação clínica, que associado aos demais dados, permite determinar a conduta. / Trauma is a major cause of morbidity and mortality in an age group including from teenagers to young adults, in a male dominat proportion, resulting in great economic and social impact. Within the complex of trauma, blunt abdominal trauma (BAT) is frequent event and presents difficulty in the evaluation and management since the clinical examination shows low sensitivity and specificity. The detection of hemoperitoneum is one of the methods of evaluation of possible indirect intra-abdominal injuries, initially using direct diagnostic abdominal paracentesis and posteriorly the diagnostic peritoneal lavage, that despite the effectiveness, have drawbacks such as invasiveness and the inability of hemoperitoneum quantification and the lesion staging, resulting in non-therapeutic laparotomies. Imaging methods provide useful information in the investigation of abdominal injuries, such as conventional and contrast radiology, ultrasound (US) and computed tomography (CT), which is the best effective method, but has its own drawbacks, such as cost, accessibility, use of ionizing radiation and contrast media and the displacement of the patient to the machine. US presents itself as an alternative in the initial evaluation of these patients as noninvasive method, with lack of harmfulness, low cost, fast answer and portability. Nevertheless, this method also has its limitations, as in cases of abdominal injuries without free fluid. This study was conducted in order to establish the performance of the US in this setting, allowing to rationalise the use of CT. For this purpose we studied 163 patients treated in the ER of HC/FMUSP, with the completion of consecutive US and CT. The population fits the usual profile of trauma victims, with 83% male, 56% in the age group between 20 and 39 years and in 73% of cases victims of traffic accidents. They were brought to the service in an average time of 51 minutes, mainly stable and with satisfactory level of consciousness. US took on average 5 minutes to be performed and the average interval until CT completion was 155 minutes. 31 (19%) of 163 patients showed positive US and 132 (81%) had negative US. 33 (20.2%) of the same 163 patients had positive CT and 130 (79.8%) had negative CT, resulting in a sensitivity of 73%, specificity of 95%, accuracy of 90% in 20% prevalence, with 77% of positive predictive value and 93% of negative predictive value. Correcting the detection of free fluid, results in 64% of sensitivity 98% of specificity 89% of accuracy in 28% of prevalence, with 93% of positive predictive value and 88% of negative predictive value of 88%. Considering the evolution of the patients, US performance was similar to that of CT. Considering need for surgery the US presented accuracy of 87%, positive predictive value of 58% and negative predictive value of 94%, near CT, with accuracy of 91%, predictive value of 67% and negative predictive value of 97%. 24% of patients with abdominal injuries did not have free fluid, as recorded by CT. The hepatorrenal space and pelvis were the most frequent sites fluid finding, 74% and 67% at US and 51% and 62% at CT, respectively. Among the factors that showed a tendency for surgery requirement were the presence of fluid in hepatorrenal space (14 of 20 patients) and the sum of liquid pockets over 3.0 cm. Detection of parenchymal lesions was low: 4 cases in 33, while only 2 of them confirmed. Among the factors that limit the US study are parenchymal lesions not associated with free fluid and retroperitoneal hematomas. Examiner experience did not influence the number of negative or positive cases, but there was a tendency to false positive with most experienced examiners and false negative with less experienced. Thus, US is an useful tool in the initial evaluation of blunt abdominal trauma, providing information for clinical evaluation, which associated with other data, tailors the management.
129

Dopplervelocimetria do fluxo normal da valva tricúspide fetal entre 11 e 13 semanas e 6 dias de gestação / Normal fetal tricuspid valve dopplervelocimetry at 11 to 13 weeks and 6 days

Ninno, Milena Almeida Prado 14 April 2010 (has links)
Objetivo: Determinar os valores dopplervelocimétricos normais do fluxo através da valva tricúspide em gestações únicas, entre 11 e 13 semanas e seis dias. Examinar a reprodutibilidade dos parâmetros avaliados e sua correlação com variáveis clínicas maternas e obstétricas. Métodos: Estudo prospectivo envolvendo 166 gestações únicas, com desfecho normal, examinadas entre 11 e 13 semanas e seis dias, no período de fevereiro de 2006 a agosto de 2008. Foram aferidas as velocidades máximas das ondas E e A, duração do ciclo cardíaco completo e sua fase diastólica e calculadas as relações onda E/onda A e diástole/ciclo. Os valores normais foram descritos pelas respectivas médias e desvio-padrão. Para análise da reprodutibilidade desses parâmetros foi calculado o coeficiente de correlação intra-classes em 12 casos examinados por dois examinadores. Regressão linear simples e multivariada foram empregadas para examinar a correlação dos parâmetros dopplervelocimétricos entre si e com a idade gestacional, a medida da translucência nucal e variáveis maternas. Resultados: Neste intervalo gestacional, os valores normais encontrados foram: onda E, 25 (± 4,6) cm/s; onda A, 42,9 (± 5,9) cm/s; relação E/A, 0,58 (± 0,07); ciclo cardíaco, 390 (± 21,1) ms; diástole, 147 (± 18) ms; relação diástole/ciclo, 0,38 (± 0,04). Entre as variáveis dopplervelocimétricas, foi observada correlação significativa entre o ciclo cardíaco e diástole (r=0,53; p<0,0001), diástole e onda A (r=-0,15; p=0,05), ondas E e A (r=0,77; p<0,0001), onda E e relação D/C (r=0,16; p=0,04), onda A e relação diástole/ciclo (r=-0,17; p=0,03). Todas as variáveis, exceto a velocidade da onda A, correlacionaram-se positivamente com a idade gestacional. Não foi observada correlação significativa das variáveis com a medida da translucência nucal, e, na comparação com as variáveis maternas, apenas a onda E e a idade materna apresentaram correlação significativa (r=-0,18, p=0,04). Os coeficientes de correlação intra-classes para a avaliação interobservador e intra-observador (examinadores um e dois) foram: onda E = 0,53 (0,53 e 0,64); onda A = 0,45 (0,46 e 0,49); ciclo cardíaco = 0,70 (0,79 e 0,84) e diástole = 0,63 (0,85 e 0,82). Conclusão: O presente estudo estabeleceu os valores normais dos parâmetros dopplervelocimétricos do fluxo através da valva tricúspide e demonstrou que tais parâmetros, com exceção da onda A, correlacionaram-se de forma positiva com a idade gestacional, e apresentaram reprodutibilidade boa/moderada. / Objective: To establish the measurements of normal tricuspid valve flow velocities at 11 to 13 weeks and 6 days to determine E-wave, A-wave, E/A ratio, cardiac cycle length, diastole length, diastole/cardiac cycle ratio, and their relationship with gestational age, nuchal translucency thickness, the characteristics of the study population, and to assess the reproducibility of flow measurements. Methods: Between February, 2006, and August, 2008, a total of 166 women with a singleton normal pregnancy between 11 and 13 + 6 weeks of gestation consented to participate in the study. Analysis of the waveforms consisted of calculation of peak velocity (cm/s) of the E-wave and A-wave, E-wave/A-wave ratio, cardiac cycle length (ms), diastole length (ms) and diastole/cardiac cycle ratio. To evaluate the intraobserver and interobserver agreement, a subgroup of 12 patients, chosen randomly, was examined twice by each examiner. For descriptive analysis of the results were calculated average and standard deviation. Simple and multivariate linear regression was used to establish the correlation between dopplervelocimetry among parameters and with gestational age, nuchal translucency thickness and the characteristics of the study population. Results: The average (± standard deviation) for transtricuspid flow-velocities waveforms parameters were: E-wave 25 (± 4.6) cm/s; A-wave 42.9 (± 5.9) cm/s; E/A ratio 0.58 (± 0.07); cardiac cycle length 390 (± 21.1) ms; diastole length 147 (± 18) ms; diastole/cardiac cycle length 0,38 (± 0.04). A statistically significant linear increase relative to gestational age was established for all parameters, except A-wave. Nuchal translucency thickness was not correlated with any parameter. A statistically significant negative regression coefficient was established for E-wave to maternal age (r=-0,18, p=0,04). A statistically significant relationship was established between: cardiac cycle length and diastole length (r=0.53; p<0.0001); diastole length and A-wave velocity (r=-0.15; p=0.05); E-wave and A-wave velocities (r=0.77; p<0.0001); E-wave velocity and D/C ratio (r=0.16; p=0.04); A-wave velocity and D/C ratio (r=-0.17; p=0.03). The intraclass correlation coeficients of interobserver and intraobsever evaluations (examiners 1 and 2) were: Ewave = 0.53 (0.53 and 0.64); A-wave = 0.45 (0.46 and 0.49); cardiac cycle = 0.70 (0.79 and 0.84) and diastole= 0.63 (0.85 and 0.82). Conclusions: These data determine normal parameters for tricuspid valve dopplervelocimetry and shows that these parameters, except A-wave, have positive correlation with gestational age, and good/moderate reproducibility.
130

Ecocardiografia fetal no primeiro trimestre da gestação / First trimester fetal echocardiography

Carvalho, Sandra Regina Marques 15 December 2006 (has links)
Os objetivos deste estudo foram determinar o índice sucesso na realização de um ecocardiograma fetal completo entre a 11ª e a 14ª semanas, estabelecer a semana mais adequada para a realização de um exame completo, mensurar os diâmetros dos anéis das valvas cardíacas e comparar os diâmetros obtidos com o comprimento crânio-nádegas (CCN) correlacionando a evolução das dimensões cardíacas com o crescimento fetal nesta fase evolutiva. Avaliamos por ecocardiografia 46 fetos que apresentavam translucência nucal e avaliação Doppler do fluxo do ducto venoso normais. O estudo ecocardiográfico fetal foi realizado por via transvaginal, entre a 11ª e a 14ª semanas, com intervalos seriados de uma semana. Em cada exame, foram obtidos os três principais planos ecocardiográficos básicos e os diâmetros das valvas aórtica, pulmonar, mitral e tricúspide. As medidas dos diâmetros valvares foram comparadas ao diâmetro do CCN. Os resultados demonstraram uma taxa de sucesso na obtenção de um ecocardiograma completo de 37% na 11ª semana, de 85% na 12ª semana e de 100% entre a 13ª e a 14ª semanas. O corte mais freqüentemente obtido, nas duas primeiras semanas, foi o eixo longo e o mais difícil de ser visibilizado foi o eixo curto. As curvas de crescimento dos diâmetros das valvas mitral, tricúspide, aórtica e pulmonar demonstraram uma correlação linear com o crescimento fetal com valores de r² de 0,74, 0,75, 0,77 e 0,73. Não houve diferença estatisticamente significativa entre os diâmetros das valvas atrioventriculares e entre os diâmetros das valvas ventriculoarteriais. A obtenção dos três planos ecocardiográficos básicos em 85% dos casos na 12ª semana e 100% dos casos, a partir da 13ª semana, demonstra que é possível a realização de um ecocardiograma fetal completo no primeiro trimeste da gestação, por via transvaginal. Houve correlação positiva entre os diâmetros valvares e o CCN demonstrando uma curva de crescimento neste período. A comparação entre diâmetros valvares mitral e tricúspide, do mesmo modo que, a comparação entre os diâmetros valvares aórtico e pulmonar não apresentaram diferenças estatisticamente significativas, sugerindo não haver dominância no tamanho destas estruturas, nesta fase do desenvolvimento em fetos normais. / The aim of this study was to assess the feasibility of performing a complete echocardiography study during the first trimester of pregnancy by transvaginal approach and to establish the best week to accomplish a complete evaluation. A correlation between the measurements of the diameters of the cardiac valves and the gestational age along this period of the fetal life was made. Forty-six fetuses with normal nuchal translucency and Doppler evaluation of the venous duct were submitted to fetal echocardiography studies by transvaginal approach between the 11 and 14 weeks of gestation with a week interval. The following measurements were obtained: mitral, tricuspid, aortic and pulmonary valves diameters and the crown-rump length (CRL). The obtained results of the cardiac dimensions were compared with the CRL in the four weeks determinations. The rates of complete echocardiography evaluation were 37%, 85% and 100% at 11, 12 and 13 – 14 weeks, respectively. The longitudinal view was the easiest to obtain (100% at 12 weeks) and the short view was the most difficult one. There was no statistically significant difference between neither the diameters of the mitral and tricuspid nor the aortic and pulmonary valves. The diameters of the valves were correlated with the CRL and a linear growing curve was obtained with values of r2 of 0.74, 0.75, 0.77 and 0.73 respectively. The study demonstrated the feasibility of a complete fetal echocardiography evaluation by transvaginal approach during the first trimester of gestation. The rate of a complete evaluation increased along the period and reached 100% at 13 weeks. The longitudinal view was the easiest to obtain with a success rate of 100% at 12 week. There was a linear correlation between de cardiac valves diameters and the cranial caudal measurement revealing a relationship between the cardiac and fetal development during this phase of fetal life. The absence of statistically significant difference between the left and right valves dimensions possibly means that there is no predominance of right or left chambers during this period of evaluation.

Page generated in 0.1108 seconds