• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 197
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • Tagged with
  • 198
  • 195
  • 98
  • 64
  • 38
  • 32
  • 25
  • 24
  • 24
  • 22
  • 22
  • 20
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Análise e quantificação tridimensional em imagens de ultra-som intravascular / Intravascular ultrasound: tridimensional quantification and analysis

Fernando José Ribeiro Sales 23 October 2009 (has links)
INTRODUÇÂO: A análise da composição das lesões in-vivo tem sido objeto de estudo de uma série de grupos de estudo sobre a doença aterosclerótica. Os métodos disponíveis para esse fim utilizam técnicas de análise espectral do sinal ultra-sônico retroespalhado antes deste ser transformado em imagens de ultra-som intravascular (IVUS), uma vez que não existem métodos que realizem tal inferência somente a partir das imagens. Neste trabalho, utilizamos técnicas de processamento de imagens e de reconhecimento de padrões para analisar a composição das lesões de acordo com a classificação proposta pela metodologia de Ultra-Som Intravascular com Histologia Virtual (IVUS-VH). MÉTODOS: Neste estudo utilizamos uma amostra de oito (08) artérias coronárias provenientes de cinco (05) pacientes, resultando num total de 96492 regiões de interesse para inferência da composição. Para a segmentação automática da interface lúmen-íntima e íntima-adventícia, aplicamos as técnicas de contornos ativos do tipo Snakes e para a determinação da energia potencial dos contornos, utilizamos técnicas de filtragem baseadas na difusão anisotrópica convencional e restritiva. Utilizamos três janelas quadradas diferentes de tamanhos 5x5, 7x7 e 9x9 pixels para extração dos atributos de texturas, dentre eles treze (13) baseados nas matrizes de co-ocorrência, seis (06) momentos invariantes à rotação, escala, translação e a ganho multiplicativo, baseados nos Momentos de Hu e propostos neste trabalho. Visando avaliar o efeito dos níveis de quantização das imagens nas matrizes de co-ocorrência, requantizamos originais de 256 níveis de cinza para 128, 64 e 32 tons. Como classificador, utilizamos o método dos k-vizinhos mais próximos (k-nn) e escolhemos os sete (07) vizinhos mais próximos como parâmetro de comparação. Como o k-nn é sensível com relação à métrica utilizada, testamos a distância euclidiana e a métrica de Mahalanobis. RESULTADOS: A segmentação automática da interface lúmen-íntima teve taxa média de acerto de 72,23% e a mediana da taxa de acertos foi de 81,20%, enquanto a taxa média de acertos para a interface íntima-adventícia foi de 80,86% e a mediana foi igual a 91,36%, considerando 495 quadros manualmente segmentados por um especialista. A melhor configuração do classificador foi utilizando a normalização de intensidades, com 256 níveis de cinza, com a janela 9x9 e usando a métrica de Mahalanobis. A taxa média de erros foi de 2.35%(DC), 20.51%(NC), 92.21%(FF) e 0.04%(FT), no entanto, se considerarmos somente três classes sem diferenciarmos os tecidos FF do FT temos a seguinte composição: 2.35% (DC), 20.51%(NC) e 0.04%(FT+FF), o que leva a uma taxa média de erros total de 5,15%. CONCLUSÕES: A classificação das lesões baseada somente em atributos de textura das imagens ainda não é possível com a nosso modelo se considerarmos os quatro tipos de tecido, uma vez que não conseguimos diferenciar de forma satisfatória dos componentes FF e FT. No entanto, se considerarmos somente três classes, temos resultados animadores, uma vez que conseguiremos identificar os componentes associados às placas ditas de maior risco de ruptura, os fibroateromas de capa fina (TCFA). Além disso, conseguimos um experimento associado ao trabalho, mostrar quantitativamente que há uma possível superestimação do componente NC ao redor de estruturas calcificadas nas imagens de IVUS-VH / INTRODUCTION: Several efforts for in vivo atherosclerotic plaque estimation has been realized worldwide. Current methods for related application are based on spectral analysis of backscattered ultrasound signals before intravascular image formation (IVUS), once there is not available techniques to perform composition analysis only from IVUS images. On this study, image processing and pattern recognition techniques has been used to classify plaques according to Intravascular Ultrasound Virtual Histology (IVUS-VH) classification. METHODS: A sample set of eight (08) coronary arteries from five (05) different patients, resulting on 96492 regions of interest for plaque analysis. For automatic segmentation of lumen-intima interface and intima-adventitia interface, active contours technique has been used. Conventional and restrictive anisotropic diffusion filters have been used for estimating the potential energy of active contours. Haralicks co-occurrence matrix and invariant moments based in Hu moments were used as features for pattern classification. Three different windows has been used on feature extraction procedure: 5x5,7x7 and 9x9 pixels. In order to analyze the influence of grey-scale quantization levels into Haralicks co-occurrence matrix, we tested four different types numbers of grey-scale levels: 32, 64,128 and 256. KNearest Neighbors algorithm as the classification rule, and we tested both Mahalanobis and Euclidian Metrics in this analysis. RESULTS: Segmentation of luminal-intimal layers average accuracy for was 72.30% and its median was 81.20%. Segmentation of intimal-adventitia layers average accuracy for was 80,86% and its median was 91,36%, for 495 manually segmented frames. Plaque classification according to IVUS-VH four classes scheme has shown not feasible with the proposed model, once average classification error-rate foe every component: 2.35%(DC), 20.51%(NC), 92.21%(FF) e 0.04%(FT). Our approach has not the ability to differentiate fibrotic tissue from fibro-fatty tissue. However, in the three classes scheme: DC, NC and (FF+FT), we achieved some encouraging results: 2.35% (DC), 20.51%(NC) e 0.04%(FT+FF), leading to an average error rate of 5,15%. With these results, a thin-cap fibroatheroma (TCFA) lesions detection algorithm for conventional IVUS images should be developed using our approach. Once TCFA plaques has been assigned to have an association with plaque rupture and sudden death, those results should be used for in vivo IVUS based TCFA detection. In an experiment related to this work, we have shown that there is an artifactual relationship between NC and DC components into VH images
162

Analise retrospectiva da aplicação do doppler transcraniano no diagnostico de morte encefalica em potenciais doadores de orgãos / Retrospective analysis of transcranial doppler examination for brain death confirmation in potential organ donors

Sardinha, Luiz Antonio da Costa 12 August 2018 (has links)
Orientadores: Sebastião Araujo, Venancio Pereira Dantas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T15:16:20Z (GMT). No. of bitstreams: 1 Sardinha_LuizAntoniodaCosta_M.pdf: 2011440 bytes, checksum: 851ec72bdf3a8bdfb52b9cb454b11066 (MD5) Previous issue date: 2008 / Resumo: Justificativa e Objetivo. No Brasil, o diagnóstico clínico de morte encefálica (ME) requer pelo menos um exame subsidiário para sua confirmação, e o Doppler transcraniano (DTC) tem sido aceito para documentar a parada circulatória cerebral (PCC). Assim, o principal objetivo do presente estudo é relatar nossa experiência com o uso do DTC na confirmação de ME. Método. Análise retrospectiva dos exames de DTC realizados entre janeiro/2001 e dezembro/2005 em 152 potenciais doadores de órgãos notificados à Organização de Procura de Órgãos do Hospital de Clínicas da Universidade Estadual de Campinas. O diagnóstico clínico de ME foi feito de acordo com o protocolo do Conselho Federal de Medicina (CFM). A artéria carótida interna (ACI) e as circulações arteriais cerebrais anteriores e posteriores foram examinadas. O achado de certos padrões específicos de alterações no DTC, conforme descritos em literatura, foram considerados para a confirmação de PCC. Resultados. Em 150 pacientes o DTC foi compatível com PCC no 1º exame. Em dois pacientes, o DTC mostrou fluxo sangüíneo cerebral residual, e um 2º exame realizado 12 horas mais tarde permaneceu ainda inconclusivo para a confirmação de PCC. Ambos foram descartados como doadores de órgãos, falecendo dentro de 48 horas. Conclusão. O DTC mostrou-se um excelente teste subsidiário para a confirmação do diagnóstico clínico de ME. O baixo custo e a portabilidade do equipamento, permitindo a realização do exame à beira do leito, têm permitido uma maior agilização e efetividade na procura e captação de órgãos para transplantes em nosso meio. / Abstract: Background and Objective. In Brazil, clinical diagnosis of brain death (BD) requires at least one ancillary test for its confirmation, and transcranial Doppler ultrasonography (TCD) has been accepted for determination of cerebral circulation arrest (CCA). The main objective of the present study is to report our experience with TCD to confirm BD in potential organ donors. Methods. Retrospective evaluation of TCD performed between January/2001 and December/2005 in 152 potential organ donors notified to an Organ Procurement Organization (OPO) at Campinas, São Paulo State, Brazil. Clinical determination of BD was done according to the protocol approved by the Brazilian Federal Council of Medicine. Internal carotid arteries and bilateral anterior and posterior cerebral circulation were insonated. The presence of specific TCD flow patterns, as previously described in medical literature, were considered for CCA confirmation. Results. In 150 patients TCD was compatible with CCA at the 1st examination. In two patients, TCD has shown residual cerebral blood flow. A 2nd examination was performed 12 hours later, remaining yet inconclusive for confirmation of CCA. Both patients were discarded as organ donors and had been died in 48 hours. Conclusion. TCD examination has shown to be an excellent ancillary test for BD confirmation. In our experience, equipment low cost and portability, allied to the possibility of bedside examination, avoiding patient transportation, has allowed a more agile and effective organ procurement for transplantation in our region. / Mestrado / Mestre em Cirurgia
163

CÃncer de mama: AvaliaÃÃo da concordÃncia imaginolÃgica e estudo anatomopatolÃgico apÃs quimioterapia neoadjuvante / Cancer of he/she suckles: evaluation of the agreement imaginological and I study anatomopatolÃgico after chemotherapy neoadjuvante.

Silvana Pinheiro de Oliveira 11 November 2005 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / O cÃncer de mama (CM) à um problema de saÃde pÃblica mundial. Uma em cada oito mulheres terà cÃncer de mama, tornando-se assim a neoplasia mais freqÃente entre as mulheres. O cÃncer de mama està ligado à identidade feminina no tocante a sua potÃncia orgÃstica e a sua sensualidade. Elaborar estratÃgicas cirÃrgicas confiÃveis pouco agressivas e menos multilantes tem sido busca de respostas a muitas pesquisas. Objetivo: O presente estudo visou avaliar a concordÃncia do volume tumoral entre a avaliaÃÃo anatomopatolÃgica e os mÃtodos de diagnÃstico por imagem dedicados a mama: Mamografia (MX), Ultra-som (US) e RessonÃncia magnÃtica (RMM), em mulheres com cÃncer de mama localmente avanÃado, submetidas à quimioterapia neoadjuvante. Pacientes e MÃtodos: Foram analisadas 95 mulheres portadoras de neoplasia mamÃria oriundas dos ambulatÃrios da Maternidade Escola Assis Chateaubriant (MEAC), Centro Regional e Integrado de Oncologia (CRIO) e Instituto do CÃncer do Cearà (ICC), no perÃodo de marÃo de 2003 a marÃo de 2005. Estas pacientes foram divididas em dois grupos. Grupo Tratamento (GT) com n=46 e Grupo Controle (GC) com n=49. Realizou-se anÃlise nÃo paramÃtrica correlacionando as variÃveis estudadas com o padrÃo ouro, ou seja, a anatomia patolÃgica. Os resultados mostraram concordÃncia na anÃlise volumÃtrica dos mÃtodos imaginolÃgicos e o padrÃo-ouro no GT nos seguintes percentuais: RMM: 0,70; US: 0,63 e MX: 0,42. Quando comparado ao grupo controle os valores encontrados foram RMM: 0,72; US: 0,70 e MX: 0,41. ConclusÃo: A RMM deteve os maiores valores de concordÃncia volumÃtrica em percentuais semelhantes nos dois grupos (GT e GC) e a MX, mÃtodo de imagem mais difundido, ofereceu os menores Ãndices de concordÃncia imaginolÃgica quando comparado com a avaliaÃÃo anatomopatolÃgica. A US apresentou valores de concordÃncia volumÃtrica satisfatÃria quando, comparada a RMM, devendo ressaltar que se trata de mÃtodo operador dependente. / The cancer of breast (CB) it is a problem of world public health. One in each eight women will have cancer of breast, becoming like this the most frequent neoplasia among the women. CB it is tied up the feminine identity concerning its potency of orgasm and her sensuality. To elaborate surgical strategic reliable not very aggressive and less mutilate has been search of answers to many researches. Objective: The present study was to evaluate the agreement of the volume of tumor to the evaluation anatomopathological and the diagnosis methods for image dedicated to he/she suckles her: Mammography (MX), Ultra-sound (US) and magnetic Resonance (RMM), in women with cancer of breast locally advanced, submitted to the neoadjuvante chemotherapy. Patient and Methods: 95 women carriers of mammary neoplasia originating from of the national health clinics of the Maternity Escola Assis Chateaubriant (MEAC), Center Regional and Integrated of Oncology (CRIO) and Institute of Cancer of Cearà (ICC) were analyzed at the period of 2003 March to 2005 March. These patient ones were divided in two groups. Treatment Group (TG) with n=46 and Control Group (CG) with n=49. Non parametric analysis correlating the variables was compared with the standard gold, the anatomopathological analysis. Results: The data showed agreement in it analyzes at volumÃtrica of the imaginolÃgicos methods and the pattern-gold in TG in the following percentages: RMM: 0.70; US: 0.63 and MX: 0.42, when compared to the control group, where were found values of RMM: 0.72; US: 0.70 and MX: 0.41. Conclusion: RMM stopped the largest values of agreement volumÃtrica in percentile similar in the two groups (GT and GC) and MX, spread image method, offered the smallest indexes of agreement imaginolÃgica when compared with the evaluation anatomopathological. US presented values of agreement satisfactory volumÃtrica when, compared RMM, should stand out that is method dependent operator.
164

DiagnÃstico da restriÃÃo de crescimento fetal pela relaÃÃo diÃmetro transverso do cerebelo/circunferÃncia abdominal / Diagnosis of the restriction of growth fetal for the relation diameter transverso of the abdominal cerebelo/circunferÃncia

Josà de Arimatea Barreto 21 May 2003 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Objetivos: testar a validade da relaÃÃo diÃmetro transverso do cerebelo (DTC) /circunferÃncia abdominal (CA) como mÃtodo diagnÃstico ultra-sonogrÃfico da restriÃÃo de crescimento fetal (RCF). Determinar, atravÃs de curva ROC (receiver operator characteristic), o melhor ponto de corte da relaÃÃo DTC/CA. Verificar se a relaÃÃo DTC/CA tem sua acurÃcia modificada na dependÃncia do tipo de RCF (simÃtrica ou assimÃtrica) ou do tempo entre a ultra-sonografia e o parto. Comparar DTC/CA, no ponto de corte obtido, com a relaÃÃo comprimento do fÃmur (CF) /circunferÃncia abdominal (CA). MÃtodo: estudo prospectivo, seccional, envolvendo 250 gestantes com gravidez Ãnica, idade gestacional precisa, feto vivo. Foram realizadas ultra-sonografias obstÃtricas atà a resoluÃÃo da gestaÃÃo, mas somente a Ãltima foi considerada para anÃlise. Os neonatos cujas relaÃÃes DTC/CA estiveram maiores do que o ponto de corte determinado pela curva ROC foram considerados acometidos por RCF. Idem para a relaÃÃo CF/CA. Considerou-se como padrÃo-ouro para o diagnÃstico de RCF os recÃm-nascidos cujos pesos situaram-se abaixo do percentil 10 para a idade gestacional nas curvas de Lubchenco et al. (1963), corrigidas para sexo. Definiu-se RCF simÃtrica neonatos com Ãndice ponderal de Rohrer situado entre 2,2 e 3.0. Aqueles com RCF cujos Ãndices fossem < 2,2 foram classificados como RCF assimÃtrica. Resultados: a prevalÃncia da RCF foi de 12,4%. O ponto de corte da relaÃÃo DTC/CA determinado pela curva ROC foi 16,15. A sensibilidade, especificidade, valores preditivos positivo e negativo, acurÃcia, razÃes de verossimilhanÃa positiva e negativa foram de 77,4%, 82,6%, 38,7%, 96,3%, 82%, 4,5 e 3,7, respectivamente. Na RCF simÃtrica a sensibilidade e especificidade foram de 80,8% e 81,7%, respectivamente. Na assimÃtrica a sensibilidade e especificidade foram 60% e 75%, respectivamente. Resultados menores do que na simÃtrica, porÃm, nÃo estatisticamente significantes (p > 0,05). No intervalo de zero a sete dias entre a Ãltima ultra-sonografia e o parto, a sensibilidade e especificidade foram de 81,5% e 82,1%, respectivamente. No intervalo de oito a 14 dias, a sensibilidade e especificidade foram de 50% e 84,3%, respectivamente, sem diferenÃa estatisticamente significante entre os dois intervalos (p > 0,05). O ponto de corte da relaÃÃo CF/CA foi de 22,65, com sensibilidade, especificidade, valores preditivos positivo e negativo, acurÃcia, razÃes de verossimilhanÃa positiva e negativa de 67,7%, 81,7%, 34,4%, 94,7%, 80%, 3,7 e 2,5, respectivamente. ConclusÃes: a relaÃÃo DTC/CA no ponto de corte 16,15 mostrou-se mÃtodo eficaz no diagnÃstico de RCF, tanto simÃtrica quanto assimÃtrica, nÃo sendo influenciada pelo tempo entre a Ãltima ultra-sonografia e o parto. Sendo mÃtodo independente da idade gestacional, à especialmente Ãtil nos casos em que este dado à ignorado. A relaÃÃo CF/CA mostrou-se menos eficaz do que a DTC/CA no diagnÃstico da RCF. / Objectives: to evaluate the validity of transverse cerebellar diameter (TCD)/abdominal circumference (AC) ratio as an ultrasonographic diagnosis method of fetal growth restriction (FGR). To calculate by receiver operator characteristic (ROC) curve the best cut-off value of TCD/AC ratio. To verify whether TCD/AC has its accuracy modified according to the dependence of type of FGR (symmetric and asymmetric) or according to the time between ultrasonography and deliverance. To compare TCD/AC ratio at its cut-off with the femur length (FL)/ abdominal circumference (AC) ratio. Method: a prospective cross-sectional study, carried out in 250 pregnant women with singleton pregnancies between 20 and 42 weeks of gestation, known accurate gestational age with ultrasound confirmation, living fetuses. Obstetrics sonographic examinations were accomplished until gestation resolution, but only the last one, within 14 days of the deliverance, was used for analysis. Neonates with TCD/AC ratio greater than the cut-off, established by ROC curve were diagnosed as FGR. The same was considered for FL/AC ratio. We classified as gold standard for FGR in new-born infants, who presented birth weight bellow 10th percentile of gestational age according to the growth curves of Lubchenco et al. (1963), corrected according to their sex. Neonates showing FGR and Rohrer ponderal index between 2,2 and 3,0 were labeled as symmetric FGR. Those showing FGR and ponderal index below 2,2 were labeled as asymmetric FGR. Results: prevalence of FGR among the study group was 12,4%. The best cut-off value calculated by ROC curve for TCD/AC ratio was 16,15. The sensitivity, specificity, accuracy, positive predictive values and negative predictive values, likelihood ratio for positive and negative tests were 77,4%, 82,6%, 38,7%, 96,3%, 82%, 4,5 and 3,7, respectively. In the symmetric FGR, sensitivity and specificity were 80,8% and 81,7%, respectively. In the asymmetric FGR, sensitivity and specificity were 60% and 75%, respectively. Results lower than in the symmetric FGR, but not statistically significant (p > 0,05). In the interval zero to seven days between sonographic examination and deliverance, sensitivity and specificity were 81,5% and 82,1%, respectively. In the interval of eight to 14 days, sensitivity and specificity were 50% and 84,3%, respectively, with no statistically significant difference (p > 0,05). The best cut-off value calculated by ROC curve for FL/AC ratio was 22,65, showing sensitivity, specificity, accuracy, positive predictive values and negative predictive values, likelihood ratio for positive and negative tests of 67,7%, 81,7%, 34,4%, 94,7%, 80%, 3,7 and 2,5, respectively. Conclusions: TCD/AC ratio at cut-off 16,15 proved to be an effective method in antenatal diagnosis of FGR, both symmetric as asymmetric, with no influence of interval between ultrasonography examination and deliverance. As a gestational age-independent method, it is useful enough in the occurrence of cases where these data are unknown. FL/AC ratio proved is not so effective as TCD/AC ratio in diagnosis of FGR.
165

Dynamic two-dimensional anorretal ultrasound in the diagnosis of Anismus in adult women - comparative study to the anal manometria and dynamic three-dimensional anorretal ultrasound / Ultra-som anorretal bi-dimensional dinÃmico no diagnÃstico de Anismus em mulheres adultas â estudo comparativo à manometria anal e ultra-som anorretal tri-dimensional dinÃmico

Rosilma Gorete Lima Barreto 30 July 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Anismus is one of the most frequent disease in carrying patients of obstructed defecation and it is being present in about 50.0% of the constipated patients. The aim of this study is to demonstrate the use of the bi-dimensional anorectal ultrasound (2-D USD) for the diagnosis of anismus and comparing the results with the anus manometry and the three-dimensional anorectal ultrasound (3-D USD). Sixty adult women with obstructed defecation symptoms were evaluated in this prospective and comparative study, coming from Colorectal Unit of the Hospital UniversitÃrio Walter CantÃdio of the Universidade Federal do CearÃ, between September 2006 to March 2007. All the patients were initially submitted to anus manometry (BAD) and then divided in two groups with 30 patients each. Group I was formed by patients without anismus at the mean age of 48,63 (24 the 69) years, while group II with carrying patients with anismus at the mean age of 51,20 (27 the 78) years. After that, patients of both groups were submitted to the 3-D and 2-D USD by an examiner who was unaware of the results of the manometries. The average size of the gotten angle with the 3-D USD at rest position of group I was 87.28  0.80 (76,5Â-96,2Â) and of 87.87  0.99 (78,5Â-109,4Â) in group II. (p=0,3220). The average size of the angle during the evacuatory effort of group I was of 93.25  1.49 (74,9Â-106,9Â) and of 85.27  1.35 (72,0Â- 101,8Â) in group II, (p=0.007). The average size of the gotten angle with the USD 2-D at rest positions of group I was 62.61  1.15 (50,9Â-75,0Â) and of 65.51  0.89 (50,8Â-73,0Â) in group II (p=0,0257). The average size of the angle during the evacuating effort of group I was of 59.75  1.42 (44,0Â-73,0Â) and of 69.40  1.06 (52,6Â-79,5Â) in group II, (p< 0,001). Comparing the differences of the angles size at rest position and during evacuatory effort of the patients of group I with group II, using 2-D and 3-D USD, there was statistically significant difference (p< 0,0001). Comparing the results between the 2-D USD with the manometry, there was agreement in 86,67% and 83,33% of the patients of group I and group II respectivelly. Comparing the results between the 2-D and 3-D USD, there was agreement of 93,33% in the evaluation of the patients of group I and of 90,0% of the patients of group II. The agreement among the three methods was 86,67% as positive predictive value and 83.33% as negative predictive value. It is concluded that the use the 2-D USD was considered efficient in the diagnosis of anismus by the high indication of agreement among the three used methods / Anismus à uma das afecÃÃes mais freqÃentes em pacientes portadores de evacuaÃÃo obstruÃda, estando presente em cerca de 50.0% dos pacientes constipados. O objetivo deste trabalho à avaliar se o USD 2-D faz o diagnÃstico de anismus, quando comparado a manometria anal e ao USD 3-D. Foram avaliadas neste estudo prospectivo e comparativo 60 mulheres adultas com sintomas de evacuaÃÃo obstruÃda, provenientes do ServiÃo de Coloproctologia do Hospital UniversitÃrio Walter CantÃdio da Universidade Federal do CearÃ, no perÃodo entre setembro de 2006 a marÃo de 2007. Todas as pacientes foram inicialmente submetidas à manometria anal (MA) e, distribuidas em dois grupos com 30 pacientes cada. O grupo I foi constituÃdo por pacientes sem anismus e com mÃdia de idade 48,63 (24 a 69) anos, enquanto o grupo II com pacientes portadoras de anismus e com mÃdia de idade 51,20 (27 a 78) anos. Em seguida, as pacientes de ambos os grupos foram submetidas à USD 3-D E 2-D por um examinador que desconhecia o resultado da manometria. O tamanho mÃdio do Ãngulo obtido com o USD 3-D no repouso do grupo I foi 87.28  0.80 (76,5Â-96,2Â) e de 87.87  0.99 (78,5Â-109,4Â) no grupo II. (p=0,3220). O tamanho mÃdio do Ãngulo no esforÃo evacuatÃrio do grupo I foi de 93.25  1.49Â(74,9Â-106,9Â) e de 85.27  1.35Â(72,0Â-101,8Â) no grupo II, (p=0.007). O tamanho mÃdio do Ãngulo obtido com a USD 2-D no repouso do grupo I foi 62.61  1.15Â(50,9Â-75,0Â) e de 65.51  0.89Â(50,8Â-73,0Â) no grupo II (p=0,0257). O tamanho mÃdio do Ãngulo no esforÃo evacuatÃrio do grupo I foi de 59.75  1.42Â(44,0Â-73,0Â) e de 69.40  1.06Â(52,6Â-79,5Â) no grupo II, (p<0.001). Comparando a diferenÃa do tamanho dos Ãngulos no repouso e no esforÃo evacuatÃrio dos pacientes do grupo I com o grupo II, ao USD 2-D e 3-D, foi observado diferenÃa estatisticamente significante (p< 0,0001). Comparando os resultados obtidos ao USD 2-D com a manometria, houve concordÃncia em 86,67% das pacientes de ambos os grupos. Comparando os resultados obtidos entre o USD 2-D com o 3-D, houve concordÃncia de 93,33% na avaliaÃÃo das pacientes do grupo I e de 90,0% das pacientes do grupo II.A concordÃncia entre os trÃs mÃtodos foi de 86,67% como valor preditivo positivo e 83,33% como valor preditivo negativo. Conclui-se que a o USD 2-D foi eficaz em averiguar o diagnÃstico do anismus pelo elevado Ãndice de concordÃncia entre os trÃs mÃtodos utilizados
166

MensuraÃÃo ultra-sonogrÃfica do colo uterino versus Ãndice de bishop na prediÃÃo do parto vaginal apÃs induÃÃo com misoprostol / The transvaginal ultrasound cervical assessment and Bishop score, in the prediction of vaginal delivery after induction of labor with misoprostol

Jose Richelmy Brazil Frota AragÃo 19 December 2008 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Objetivos: comparar a mensuraÃÃo ultra-sonogrÃfica transvaginal do colo uterino e o Ãndice de Bishop, na prediÃÃo do parto vaginal apÃs induÃÃo do trabalho de parto com misoprostol 25mcg, assim como, determinar os principais fatores relacionados à evoluÃÃo para parto vaginal. Sujeitos e MÃtodos: realizou-se estudo de validaÃÃo de tÃcnica diagnÃstica na Maternidade-Escola Assis Chateaubriand da Universidade Federal do CearÃ, com 126 gestantes com indicaÃÃo para induÃÃo do trabalho de parto que foram avaliadas pelo Ãndice de Bishop e ultra-sonografia transvaginal para mensuraÃÃo cervical. As pacientes foram submetidas à ultra-sonografia obstÃtrica transabdominal, para avaliaÃÃo da estÃtica e peso fetais e Ãndice de lÃquido amniÃtico, e à cardiotocografia basal para avaliaÃÃo da vitalidade fetal. Procedeu-se à induÃÃo do trabalho de parto com misoprostol vaginal e sublingual, um dos comprimidos contendo 25mcg da droga e o outro apenas placebo. Os comprimidos foram administrados a cada seis horas, em um numero mÃximo de oito. A anÃlise estatÃstica foi realizada com o programa SPSS 10.0 (SPSS Co, Chicago, IL, USA), utilizando-se distribuiÃÃo de frequÃncias, mÃdias, desvios-padrÃo e medianas; assim como, anÃlise univariada e construÃÃo de curvas ROC, correlacionando Ãndice de Bishop e parto vaginal, e medida ultra-sonogrÃfica do colo uterino e parto vaginal. Em anÃlise multivariada foram pesquisadas outras variÃveis relacionadas ao parto vaginal. Resultados: atravÃs de curva ROC correlacionando a mensuraÃÃo do colo uterino por ultra-sonografia transvaginal e a evoluÃÃo para o parto vaginal, evidenciou-se uma Ãrea sob a curva de 0,513 com p=0,801. Outra curva ROC, analisando a relaÃÃo da avaliaÃÃo cervical pelo Ãndice de Bishop com o parto vaginal, demonstrou Ãrea sob a curva de 0,617 com p=0,025. AtravÃs de anÃlise de regressÃo logÃstica mÃltipla, evidenciou-se paridade &#8805; 1, escore de Bishop &#8805; 4 e presenÃa de lÃquido amniÃtico claro como associados à evoluÃÃo para o parto vaginal. ConclusÃes: a medida ultra-sonogrÃfica transvaginal do colo uterino nÃo foi boa preditora da evoluÃÃo para parto vaginal em pacientes com trabalho de parto induzido com misoprostol. O Ãndice de Bishop foi melhor preditor para parto vaginal nestas circunstÃncias. Os fatores preditivos mais importantes para parto vaginal, apÃs induÃÃo com misoprostol, foram paridade &#8805; 1, Ãndice de Bishop &#8805; 4 e presenÃa de lÃquido amniÃtico claro
167

Acurária do estudo dos jatos ureterais à ultra-sonografia do Doppler Colorido no diagnóstico das hidronefroses / Diagnostic accuracy of color Doppler sonographic study of the ureteric jets in evaluation of hydronephrosis

José de Bessa Junior 10 August 2007 (has links)
Introdução e Objetivo: Hidronefrose e Obstrução são condições associadas, entretanto dilatações da via excretora podem ocorrer na ausência de obstruções clinicamente importantes. Ultra-sonografia convencional e Renograma com Diuréticos são os métodos diagnósticos complementares mais utilizados na avaliação das hidronefroses na infância. Recentes trabalhos têm demonstrado a possibilidade de observarmos os jatos ureterais com o Estudo Ultra-sonográfico com Doppler Colorido e sugerido a sua aplicação no diagnóstico diferencial das hidronefroses. O objetivo do presente trabalho foi avaliar a aplicabilidade do estudo dos jatos ureterais como método diagnóstico na identificação das hidronefroses obstrutivas e não obstrutivas na população pediátrica. Métodos: Foram estudadas 48 crianças (35 meninos e 13 meninas) com idade que variou de um mês a 14 anos (mediana de 4 anos), que se apresentaram com Hidronefroses Unilaterais, Graus III e IV, e com suspeita de obstrução da junção pieloureteral. Todos os sujeitos foram submetidos ao Estudo dos jatos ureterais e ao Renograma com Diuréticos num período de duas semanas. As unidades hidronefróticas foram consideradas obstruídas quando a Função Renal Diferencial era menor do que 40%, ou em indivíduos mais velhos que apresentavam dor lombar intermitente. Os jatos ureterais de cada meato foram contados por um período de 5 minutos e considerados separadamente. Freqüência Relativa dos Jatos (FRJ) foi definida como o numero de jatos ureterais no lado afetado dividido pela soma dos jatos ureterais observados bilateralmente. Resultados: Vinte e duas (45,8%) unidades hidronefróticas foram consideradas obstruídas.A média da FRJ diferiu significativamente entre as hidronefroses obstrutivas (0,09 ± 0,15) e não obstrutivas (0,41 ± 0,11). (p<0.001). Análise da Curva ROC revelou que FRJ < 0,25 é o melhor valor que distingue as hidronefroses obstrutivas e não obstrutivas e o faz corretamente em 91,2 % dos casos, com uma Sensibilidade de 86,4% (IC95%=78,6-98,2%) e Especificidade de of 96.15% (IC95%=87.8-99%). O Índice de Probabilidade Positivo foi de 22,45 e a Razão de Chances Diagnóstica de 158,3. A área sob a curva ROC foi de 0,91 (IC95%=0,86-0,98) indicando a excelente acurácia do método. Conclusões: FRJ < 25 % mostrou ser um bom indicador de obstrução nas hidronefroses unilaterais da infância. O estudo dos jatos ureterais a Ultrasonografia com Doppler Colorido é método simples, não invasivo e pode ser utilizado na abordagem inicial e no seguimento, na diferenciação das hidronefroses obstrutivas e não obstrutivas na população pediátrica / Introduction and Objective: Hydronephrosis (HN) and obstruction are closely associated, but upper urinary tract dilatation can occur without significant obstruction. Despite some pitfalls, conventional ultrasonography and diuretic renography (DR) are the main modalities in the evaluation of HN in children. Recent reports have demonstrated the usefulness of Color Doppler Ultrasonography (CDUS) as a reliable method to identify the ureteric jets (UJ) in the bladder. The aim of this study was to evaluate CDUS evaluation of the UJ in the bladder as a diagnostic tool to distinguish obstructive from non-obstructive dilatations of the upper tract in pediatric population. Methods: We evaluated 48 patients (35 boys and 13 girls), aged 1 month to 14 years (median = 4 ys.), who presented with unilateral grade III and IV hydronephrosis suspicious of pyeloureteral junction obstruction. All patients underwent DR and evaluation of UJ by transverse CDSG of the bladder within a maximum of 2 weeks. Obstruction was considered in the DR when the hydronephrotic unit showed Differential Renal Function of less than 40%, or when symptomatic intermittent renal colic was present in older children. The number of UJ was counted over a 5 min period and its frequency was calculated for each ureteral orifice. Relative Jet Frequency (RJF) was defined as the UJ frequency of hydronephrotic side divided by total UJ frequency. Receiver-Operating Characteristic (ROC) plots were constructed to determine the best cuttoff for RJF, in order to identify renal units with obstructive hydronephrosis. Results:Twenty-two(45.8%) hydronephrotic units were considered obstructed. The mean RJF differed significantly between obstructive (0.09 ± 0,15) and non-obstructive hydronephrosis (0.41± 0.11)(p<0.001). ROC analysis revealed that RJF< 0.25 was the best threshold and it correctly discriminates obstruction in 91.2% of the childrens with a sensitivity of 86.4% (95%CI=78.6-98.2%) and specificity of 96.15% (95%CI=87,8-99%). The Positive Likelihood Ratio was 22.45 and Diagnostic Odds Ratio was 158.3.The area under the ROC curve was 0.91 (95%CI=0.86-0.98), indicating excellent discrimination power. Conclusions: In this study RJF < 25% was found to be a good indicator of obstruction in children with unilateral hydronephrosis. CDUS evaluation of UJ is an easy and non-invasive method that can be used as an initial diagnostic tool and in follow-up cases, to differentiate obstructed from non-obstructed hydronephrosis in the pediatric population
168

Mobilidade diafragmática em pacientes com DPOC: avaliação ultra-sonográfica do deslocamento crânio-caudal do ramo esquerdo da veia porta / Diaphragm mobility in COPD patients: ultrasound assessment of the craniocaudal displacement of the left branch of the portal vein

Wellington Pereira dos Santos Yamaguti 22 June 2007 (has links)
O objetivo desse estudo foi avaliar a relação da mobilidade diafragmática com a função pulmonar e a força muscular respiratória em indivíduos com DPOC, utilizando a mensuração ultra-sonográfica do deslocamento crânio-caudal do ramo esquerdo da veia porta. Foram estudados 54 pacientes portadores de DPOC com hiperinsuflação pulmonar e 20 sujeitos saudáveis. Os parâmetros avaliados foram: mobilidade diafragmática, função pulmonar e as pressões respiratórias máximas. Pacientes com DPOC apresentaram menor mobilidade do diafragma (36,46 ± 10,90 mm) quando comparados a indivíduos saudáveis (46,33 ± 9,47) (p = 0,001). Nos indivíduos portadores de DPOC foram verificadas uma forte correlação com os parâmetros da função pulmonar que quantificam o aprisionamento de ar (VR: r = -0,60; p < 0,001; VR/CPT: r = -0,72; p < 0,001), uma moderada correlação com a obstrução de vias aéreas (VEF1: r = 0,55, p < 0,001; resistência das vias aéreas: r = -0,32, p = 0,02) e uma fraca correlação com a hiperinsuflação pulmonar (CPT: r = -0,28, p = 0,04). Não foi observada relação entre a mobilidade do diafragma e a força muscular respiratória (PImax: r = -0,11 e p = 0,43; PEmax: r = 0,03 e p = 0,80). Nossos resultados sugerem que a redução da mobilidade do diafragma em pacientes com DPOC ocorre principalmente devido ao aprisionamento de ar, não sendo influenciada pela hiperinsuflação pulmonar ou pela força muscular respiratória. / The purpose of this study was to use ultrasound to measure the craniocaudal displacement of the left branch of the portal vein in order to evaluate the relationship between pulmonary function and diaphragm mobility, as well as that between respiratory muscle strength and diaphragm mobility, in COPD patients. We studied 54 COPD patients with pulmonary hyperinflation, together with 20 healthy subjects. Pulmonary function, maximal respiratory pressures, and diaphragm mobility were evaluated. COPD patients presented less diaphragm mobility than did healthy individuals (36.46 +/- 10.90 mm vs. 46.33 +/- 9.47 mm, respectively) (p = 0.001). In COPD patients, we found that diaphragm mobility correlated strongly with pulmonary function parameters that quantify air trapping (RV: r = -0.60; p < 0.001; RV/TLC: r = -0.76; p < 0.001), moderately with airway obstruction (FEV1: r = 0.55, p < 0.001; airway resistance: r = -0.32, p = 0.02), and weakly with pulmonary hyperinflation (TLC: r = -0.28, p = 0.04). No relationship was observed between diaphragm mobility and respiratory muscle strength (maximal inspiratory pressure: r = -0.11 and p = 0.43; maximal expiratory pressure: r = 0.03 and p = 0.80). The results of this study suggest that the reduction in diaphragm mobility in COPD patients occurs mainly due to air trapping and is not influenced by respiratory muscle strength or pulmonary hyperinflation.
169

Ecocardiografia fetal no primeiro trimestre da gestação / First trimester fetal echocardiography

Sandra Regina Marques Carvalho 15 December 2006 (has links)
Os objetivos deste estudo foram determinar o índice sucesso na realização de um ecocardiograma fetal completo entre a 11ª e a 14ª semanas, estabelecer a semana mais adequada para a realização de um exame completo, mensurar os diâmetros dos anéis das valvas cardíacas e comparar os diâmetros obtidos com o comprimento crânio-nádegas (CCN) correlacionando a evolução das dimensões cardíacas com o crescimento fetal nesta fase evolutiva. Avaliamos por ecocardiografia 46 fetos que apresentavam translucência nucal e avaliação Doppler do fluxo do ducto venoso normais. O estudo ecocardiográfico fetal foi realizado por via transvaginal, entre a 11ª e a 14ª semanas, com intervalos seriados de uma semana. Em cada exame, foram obtidos os três principais planos ecocardiográficos básicos e os diâmetros das valvas aórtica, pulmonar, mitral e tricúspide. As medidas dos diâmetros valvares foram comparadas ao diâmetro do CCN. Os resultados demonstraram uma taxa de sucesso na obtenção de um ecocardiograma completo de 37% na 11ª semana, de 85% na 12ª semana e de 100% entre a 13ª e a 14ª semanas. O corte mais freqüentemente obtido, nas duas primeiras semanas, foi o eixo longo e o mais difícil de ser visibilizado foi o eixo curto. As curvas de crescimento dos diâmetros das valvas mitral, tricúspide, aórtica e pulmonar demonstraram uma correlação linear com o crescimento fetal com valores de r² de 0,74, 0,75, 0,77 e 0,73. Não houve diferença estatisticamente significativa entre os diâmetros das valvas atrioventriculares e entre os diâmetros das valvas ventriculoarteriais. A obtenção dos três planos ecocardiográficos básicos em 85% dos casos na 12ª semana e 100% dos casos, a partir da 13ª semana, demonstra que é possível a realização de um ecocardiograma fetal completo no primeiro trimeste da gestação, por via transvaginal. Houve correlação positiva entre os diâmetros valvares e o CCN demonstrando uma curva de crescimento neste período. A comparação entre diâmetros valvares mitral e tricúspide, do mesmo modo que, a comparação entre os diâmetros valvares aórtico e pulmonar não apresentaram diferenças estatisticamente significativas, sugerindo não haver dominância no tamanho destas estruturas, nesta fase do desenvolvimento em fetos normais. / The aim of this study was to assess the feasibility of performing a complete echocardiography study during the first trimester of pregnancy by transvaginal approach and to establish the best week to accomplish a complete evaluation. A correlation between the measurements of the diameters of the cardiac valves and the gestational age along this period of the fetal life was made. Forty-six fetuses with normal nuchal translucency and Doppler evaluation of the venous duct were submitted to fetal echocardiography studies by transvaginal approach between the 11 and 14 weeks of gestation with a week interval. The following measurements were obtained: mitral, tricuspid, aortic and pulmonary valves diameters and the crown-rump length (CRL). The obtained results of the cardiac dimensions were compared with the CRL in the four weeks determinations. The rates of complete echocardiography evaluation were 37%, 85% and 100% at 11, 12 and 13 – 14 weeks, respectively. The longitudinal view was the easiest to obtain (100% at 12 weeks) and the short view was the most difficult one. There was no statistically significant difference between neither the diameters of the mitral and tricuspid nor the aortic and pulmonary valves. The diameters of the valves were correlated with the CRL and a linear growing curve was obtained with values of r2 of 0.74, 0.75, 0.77 and 0.73 respectively. The study demonstrated the feasibility of a complete fetal echocardiography evaluation by transvaginal approach during the first trimester of gestation. The rate of a complete evaluation increased along the period and reached 100% at 13 weeks. The longitudinal view was the easiest to obtain with a success rate of 100% at 12 week. There was a linear correlation between de cardiac valves diameters and the cranial caudal measurement revealing a relationship between the cardiac and fetal development during this phase of fetal life. The absence of statistically significant difference between the left and right valves dimensions possibly means that there is no predominance of right or left chambers during this period of evaluation.
170

Avaliação do leito arterial distal em revascularização de membros inferiores: estudo comparativo entre ecografia-doppler, arteriografia e medidas diretas de fluxo no intra-operatório / Color-flow duplex hemodynamic assessment of runoff in ischemic lower limb revascularization: a comparative study among preoperative duplex scanning, arteriography and intraoperative direct out flow measurements

Fabio Henrique Rossi 22 September 2006 (has links)
A cirurgia de restauração circulatória arterial no paciente portador de isquemia crítica de membros inferiores apresenta indicações clínicas e técnica operatória já bastante estudadas e definidas. Ainda hoje, no entanto, um considerável número de enxertos evolui para oclusão. Entre as causas relacionadas à falência precoce, podemos destacar a resistência do leito distal receptor do enxerto. Interessou-nos estudar a existência de correlação hemodinâmica entre a Ecografia-Doppler, a Arteriografia pré-operatória, e medidas diretas intra-operatórias de resistência do leito arterial receptor do enxerto. Foram estudadas 68 operações de revascularização de membros inferiores portadores de isquemia crítica. A Ecografia-Doppler foi considerada tecnicamente satisfatória em 93,2%. Foi verificada a presença de correlação hemodinâmica positiva entre os métodos descritos acima (Teste de Pearson), particularmente para as artérias distais. Concluímos que a Ecografia-Doppler, além de definir as características anatômicas da artéria a ser revascularizada, pode auxiliar no estudo hemodinâmico do leito arterial receptor do enxerto e dessa forma auxiliar na definição do prognóstico do enxerto e no estabelecimento da melhor estratégia terapêutica a ser tomada ainda no período pré-operatório / The clinical indications and the surgical technique regarding arterial revascularization in patients with critical lower limb ischemia have been thoroughly studied and well determined in the literature. However, a considerable number of grafts evolutes to occlusion even nowadays. Among the factors known to contribute to early graft failure the resistance of the outflow arterial bed stands out. The purpose of this study is to verify Duplex Scanning hemodynamic correlation power with preoperative arteriography and direct intraoperative resistance measurements. Sixty-eight (68) lower limb revascularizations were studied. Preoperative Duplex Scanning was considered satisfactory in 93,2% of the cases. A positive hemodynamic correlation among the methods described above (Pearson\'s correlation test), particularly for distal arteries, has been verified. We conclude that preoperative Duplex Scanning, apart from defining the anatomic characteristics of the artery to be revascularized, can be helpful in the hemodynamic study of the arterial bed receiving the graft, making it easier to establish the graft prognosis and define the best therapeutic strategy to be adopted in the preoperative period.

Page generated in 0.0561 seconds