• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 197
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • Tagged with
  • 198
  • 195
  • 98
  • 64
  • 38
  • 32
  • 25
  • 24
  • 24
  • 22
  • 22
  • 20
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Efeito cicatricial do extrato de Calendula Officinalis L. associado à aplicação do ultrasom terapêutico em feridas induzidas em pele de ratos / Patricia Pacheco Tyski Suckow ; orientadora, Auristela Duarte de Lima Moser

Suckow, Patricia Pacheco Tyski January 2012 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Bibliografia: f, 89-95 / Introdução. A cicatrização constitui um conjunto dinâmico de alterações teciduais, importantes na manutenção da integridade do organismo e surge como resposta a uma agressão tecidual. O Ultrassom Terapêutico (UST) é um recurso que promove a aceleração da / Introduction. Healing is a dynamic set of tissue changes, important in maintaining the integrity of the body and emerges as a response to a tissue aggression. Therapeutic ultrasound is a resource that promotes acceleration of wound healing of injuries, th
72

Ultra-sonografia ovariana e concentrações séricas de progesterona em novilhas Holandesas, Gir e mestiças Holandês-Gir / Ovarian ultrasonography and progesterone concentration in Holstein, Gir and crossbred heifers

Almeida, Cláudia D’Avila de 17 April 1998 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-06-23T09:43:16Z No. of bitstreams: 1 texto completo.pdf: 191840 bytes, checksum: 42829f2287c16813d005452b0de95e37 (MD5) / Made available in DSpace on 2016-06-23T09:43:16Z (GMT). No. of bitstreams: 1 texto completo.pdf: 191840 bytes, checksum: 42829f2287c16813d005452b0de95e37 (MD5) Previous issue date: 1998-04-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A pesquisa foi conduzida utilizando-se 21 novilhas, apresentando ciclo estral regular, de três grupos genéticos (Holandês, Gir e Mestiças Holandês-Gir); que foram mantidas nas mesmas condições de manejo e alimentação. Cada animal recebeu uma aplicação de luteolítico e, aqueles que não apresentaram estro, receberam uma segunda aplicação 11 dias após. A partir do estro, a atividade ovariana foi monitorada por exames ultra-sonográficos e foram coletadas amostras sangüíneas, a cada dois dias, para dosagem de progesterona, por radioimunoensaio (RIA), durante dois ciclos estrais consecutivos. As áreas dos ovários e o diâmetro do maior folículo presente nos ovários foram mensurados, e os folículos presentes nos ovários foram contados. As novilhas mestiças apresentaram maior área de ovário que as novilhas Gir e Holandesas, que não diferiram entre si. O número de folículos (≥4mm) foi maior nas novilhas Gir, e o diâmetro do maior folículo foi maior nas novilhas Holandesas. A concentração média de progesterona foi mais elevada nos animais mestiços que nos outros grupos genéticos. Em todas as avaliações das características reprodutivas as novilhas mestiças apresentaram valores superiores ou iguais aos da raça que se destacou no presente estudo. / Twenty one heifers with regular estrus cycle from the three genetics groups (Crossbred Holstein-Gir, Gir and Holstein) in the same management and nutrition conditions, received an application of luteolytic and those animals that did not showed estrus behavior received a second application eleven days later. From the onset of estrus on, the ovarian activity was monitored by ultrasonographyc examination and blood samples were collected for the progesterone determination by radioimunoessay (RIA), both in alternate days, during two consecutive estrous cycles. The ovary area and the diameter from the biggest follicle were mensuared, and the follicles (≥ 4mm) were counted. The ovary area from crossbred heifers was greatest than the Gir and Holstein ones, and the last ones did not differ between themselves. The number of follicles (≥ 4mm) was greater in the Gir heifers, and the diameter of the biggest follicle was greater in the Holstein heifers. The progesterone level was increased in crossbred animals as compared to the other genetics groups of heifers. The crossbred heifers showed greater or similar values as compared to the ones from the other genetics groups on the reproductive characteristics studied. / Não foram encontrados o currículo lattes e o CPF do autor.
73

Nível sérico de ácido hialurônico e sua relação com o escore ultra-sonográfico na avaliação da hepatopatia em pacientes com fibrose cística

Rocha, Renata Gonçalves January 2007 (has links)
A hepatopatia da fibrose cística (FC) é uma complicação grave sendo descrita como terceira causa de morte nestes pacientes. Sua prevalência é muito variável, desde 14,3% até 41% em crianças e adolescentes. A discrepância entre os diferentes estudos clínicos se deve à forma utilizada para o diagnóstico da hepatopatia (características clínicas, bioquímicas e/ou ultra-sonográficas), à idade dos pacientes selecionados, ao tipo de estudo empregado (transversal ou longitudinal) e também, à falta de um marcador específico e sensível de disfunção hepatobiliar. Em 1995, Williams et al, elaboraram um escore ultra-sonográfico que mostrou boa relação com as alterações laboratoriais hepáticas pretendendo, desta forma, graduar o nível da lesão hepática. O escore foi elaborado por meio da avaliação do padrão do parênquima hepático, do contorno do fígado e do grau de ecogenicidade periportal. Quanto aos marcadores não invasivos para diagnosticar a doença hepática, vários tem sido estudados, entre eles o ácido hialurônico (AH).O AH é o maior mucopolissacarídeo componente da matriz extracelular, é encontrado na maioria dos tecidos e fluidos corporais, particularmente abundante em tecido conectivo frouxo. É sintetizado na membrana citoplasmática de fibroblastos e de outras células, sendo que uma pequena parte é metabolizada neste local. Através dos vasos linfáticos chega à corrente sanguínea e é rapidamente eliminada pelo fígado, ao nível do sinusóide hepático. Neste estudo buscamos relacionar as alterações ultra-sonográficas com o nível sérico de AH e, desta forma, realizar o diagnóstico precoce da hepatopatia da FC. Foi realizado um estudo transversal em 57 pacientes com FC, todos caucasóides, que apresentavam uma média de idade de 10,2 + 4,9 anos. A avaliação constou de dados clínicos, laboratoriais e ultra-sonográficos. Os pacientes foram classificados de acordo com um escore ultra-sonográfico em:Grupo 1 (G1) – ausência de doença hepática: escore 3; - Grupo 2 (G2) – doença hepática moderada: escore 4 – 6; - Grupo 3 (G3) – doença hepática grave: escore 7 - 9. O nível sérico do ácido hialurônico foi medido através da técnica de ELISA (Enzyme Linked Immunoassay) e comparado com 23 controles saudáveis. Vinte e nove pacientes foram incluídos no G1, dezoito pacientes no G2 e dez pacientes no G3. Os pacientes do sexo masculino apresentaram escore ultra-sonográfico mais alterado (P= 0,018). O nível sérico da ALT e da AST foram consideravelmente mais elevados no G3 do que no G1. O nível sérico da GGT foi mais elevado no G3 do que no G1 e G2. A porcentagem do volume expiratório forçado no primeiro segundo (%VEF1) apresentou uma correlação positiva fraca com o escore Z P/I (r= 0,31/P= 0,031). O nível sérico de AH variou de 1,8 a 45 ng/mL (mediana= 13,9), apresentou uma mediana semelhante entre os grupos 1,2,3 e o grupo controle (P= 0,431), entre os grupos 1,2 e 3 (P= 0,24) e também, quando comparado cada grupo com o grupo controle (todos P> 0,1). Não houve correlação entre o nível sérico de AH e o escore ultra-sonográfico (P= 0,164). Desta forma, concluímos que o AH isoladamente não se mostrou um marcador da hepatopatia causada pela fibrose cística. / Cystic fibrosis (CF) liver disease (LD) is a serious complication, being described as the third cause of death in these patients. Its prevalence varies widely, from 14.3% to 41.0% in children and adolescents. The discrepancy shown by the various clinical studies is due to the method employed for the diagnosis of LD (clinical, biochemical and/or ultrasonographic characteristics), the age of selected patients, the type of study (crosssectional or longitudinal) and the absence of a specific and sensitive marker. In 1995, WILLIAMS et al, developed an ultrasonographic score that showed a good relation to liver biochemical alterations, in order to measure the liver involvement. The score was elaborated through an evaluation of three cardinal features of hepatic ultrasound in CF: coarseness of the parenchyma, nodularity of the liver edge and increased periportal echogenicity. Regarding non-invasive markers to diagnose the hepatic disease, several have been studied, among them the hyaluronic acid (HA). Hyaluronic acid is a major mucopolysaccharide in the extracellular matrix, found in most body tissues and fluids, particularly abundant in loose connective tissue. It is synthetized in the cytoplasmatic membrane of fibroblasts and other cells, with a small part being metabolized there. Through the lymph vessels, it reaches the bloodstream and is rapidly eliminated by the liver, at the hepatic sinusoid level. In this study, we attempted to correlate the ultrasound findings with HA serum level, and thus, obtain the early diagnosis of CFLD. A cross-sectional study was performed with 57 patients with CF, all white individuals presenting mean age of 10.2 + 4.9 years. The evaluation considered clinical, laboratorial and ultrasonographic data. The patients were classified according to an ultrasonographic score into: - Group 1 (G1) – absence of liver disease: score 3- Group 2 (G2) – moderate liver disease: score 4 – 6; - Group 3 (G3) – severe liver disease: score 7 - 9. HA serum level was measured by ELISA (Enzyme Linked Immunoassay) in the CF patients and 23 healthy controls. Twenty-nine patients were included in G1, 18 in G2 and 10 in G3. The male patients presented an ultrasonographic score with more alterations (P= 0,018). The serum levels of ALT and AST in G3 were considerably higher than in G1. The serum level of GGT in G3 was higher than in G1 and G2. The percent of forced expiratory volume in the first second (%FEV1) presented a small positive correlation with Z score W/A (r= 0.31/P= 0.031). HA serum level ranged from 1.8 to 45 ng/mL (mean = 13.9), and presented a similar mean value between Groups 1,2,3 and the control group (P= 0.431), among Groups 1,2 and 3 (P= 0.24), as well as when comparing each group to the control group (all P> 0.1). There was no correlation between HA serum level and ultrasonographic score (P= 0.164). Thus, we concluded that HA lonely cannot be considered as a marker of liver disease caused by cystic fibrosis.
74

Rastreamento da insuficiência placentária através do Doppler das artérias uterinas por via transvaginal entre 22 e 24 semanas de gestação

Dias, Ricardo dos Santos Palma January 2005 (has links)
Resumo não disponível
75

Comparação entre a ultra-sonografia com dopplervelocimetria e análise hormonal na predição do achado de espermatozóides em biópsia testicular de pacientes com azoospermia

Souza, Carlos Augusto Bastos de January 2004 (has links)
Resumo não disponível.
76

Dopplervelocimetria renal em gatos Persas: valores de referência / Renal dopplervelocimetry in Persian cats: normal parameters

Cibele Figueira Carvalho 15 October 2009 (has links)
As afecções renais são frequentes em pequenos animais, especialmente em gatos. O ultrassom Doppler é uma técnica complementar à metodologia convencional com diversas aplicações na avaliação do sistema urinário. A literatura veterinária apresenta uma grande lacuna em relação a estudos determinando os parâmetros de normalidade e suas variações. Este estudo teve como objetivos determinar valores dopplervelocimétricos de referência na avaliação renal em gatos. Foi realizado um estudo prospectivo com 50 unidades renais de gatos adultos jovens da raça Persa, as quais foram examinadas ao ultrassom Doppler, sendo 13 fêmeas e 12 machos com idade entre 12 e 60 meses. Os animais foram selecionados como hígidos, através de exames laboratoriais, pressão arterial sistólica e ultrassonografia modo-B. Mensurou-se o calibre da aorta (AO) e das artérias renais (AR). Determinaram-se os parâmetros dopplervelocimétricos normais para as artérias renais e interlobares (AI) em cada animal: velocidade de pico sistólico (VPS), aceleração sistólica inicial (ASi) e os índices de resistividade (IR). Para a AO obteve-se VPS 53,17 ± 13,46 cm/s e média de diâmetro de 0,38 ± 0,04 cm. A média do diâmetro da AR foi de 0,15 ± 0,02 cm. Não foram observadas diferenças estatisticamente significantes nos dados obtidos nas AR e AI entre os lados e entre si. Considerando-se ambas as AR obteve-se a média de VPS 41,17 ± 9,40 cm/s, ASi 1,12 ± 1,14 m/s2 e IR 0,53 ± 0,07. Correlacionando-se os valores de VPS entre AR e AO obteve-se um índice de relação renal/ aorta com média de 0,82 ± 0,30 e um valor normal máximo de 1,52. Nas AI obteve-se VPS 31 ± 9 cm/s e IR 0,52 ± 0,07. Correlacionandose os valores de VPS entre AR e AI obteve-se um índice de relação renal/interlobar com um valor máximo de 3,5. Foram estabelecidos parâmetros dopplervelocimétricos normais do rim em gatos Persa e um índice renal/aórtico e renal/interlobar semelhante ao utilizado em humanos para monitorar alterações hemodinâmicas renais. Estes resultados podem balizar o início de outros estudos para determinar se a idade e outras condições clínicas ocasionam efeito nestes valores / Renal diseases are usual in small animals, especially in cats. Doppler ultrasound is a complementary tool for conventional method with several indications evaluates urinary system. There are few articles in veterinary literature studying normal parameters. This study has a goal to determine dopplervelocimetrics values for renal evaluation. Prospective study was made performing Doppler ultrasound exams of fifty renal units of adult Persian cats. The animals were classified as healthy by means of laboratorial exams, measurement of arterial systolic pressure and B-mode ultrasonography. Aortic (AA) and renal (RA) arteries diameters were measured. Normal Doppler velocimetric parameters were evaluated for renal and interlobar arteries (IA) of each animal: maximal systolic blood flow velocity (MSV), initial systolic acceleration of blood flow (ISA) and resistivity index (RI). Renal arterial diameter was 0.15 ± 0.02 cm. It was calculated aorta VPS 53.17 ± 13.46 cm/s and diameter of 0.38 ± 0.04 cm. It was not observed any statistical significant difference between the sides or arteries themselves. Considering both renal arteries it was calculated MSV 41.17 ± 9.40 cm/s, ISA 1.12 ± 1.14 m/s2 and RI 0.54 ± 0.07. Correlation of velocities of renal artery and aorta resulted in a renal/aortic ratio of 0.82 ± 0.30 and with 1.52 as maximal normal value. It was calculated for all interlobar arteries MSV 31 ± 9 cm/s and RI 0.52 ± 0.07. Correlation of velocities of renal and interlobar arteries resulted in a renal/interlobar ratio with 3.5 as maximal normal value. Normal dopplervelocimetric parameters of renal vasculature and an index renal-aortic ratio and renal-interlobar ratio were established in Persian cats similar as used in humans to monitorizing renal hemodynamic changes. These results may provide the starting of further studies to determine if age and others clinical conditions have an effect on these values
77

Usabilidade aplicada ao design ergonômico de transdutores de ultra-sonografia: uma proposta metodológica para avaliação e análise do produto.

Paschoarelli, Luis Carlos 01 January 2003 (has links)
Made available in DSpace on 2016-06-02T19:50:01Z (GMT). No. of bitstreams: 1 TeseLCP.pdf: 9583238 bytes, checksum: c2137a635f05713171b01b2d0f229f21 (MD5) Previous issue date: 2003-01-01 / The usability is one of the main aspects of the performance and quality of the interface hand/instruments whose applicability is based on methodologies of ergonomic design. In spite of the technological evolution, some hand instruments still do not attend the criteria of usability and may generate ergonomic problems in users. An example of it is the transductor employed in breast ultrasonography (US) occupational activities, which requires large biomechanical efforts. This study aimed at proposing a method of assessment and analysis based on subjective and physiological records during the application of criteria of usability in the ergonomic redesign of the transductor for US breast examinations. In order to conductthe physiological records, a Biometrics electrogoniometer was used for the analysis of wrist movements, and FSRs sensors were used for the analysis of palmar pressure. As for the subjective assesments, graphic scales of perception were applied. The collection of data occurred in experimental phases: First Experimentation assessment of wrist postures during the simulation of activity with two commercial types of transductors (n= 18); Ergonomic design application of the criteria of usability in the redesign and prepraration of the mock-up; Second Experimentation assessment of the postures and points of palmar pressure during the simulation of activity with the new mock-up and the commercial transductors (n = 10); Ergonomic design/project revision revision of the criteria of usability and development of two new mock-ups; Third experimentation assessment of the postures and points of palmar pressure during the simulation of activity with the new mock-ups and the commercial transductors (n = 10); Fourth experimentation subjective assessment of all the transductors (n = 11). The results of the first experimentation indicated high median and maximal amplitudes. The ergonomic design turned up into mock-up 01. The results of the second experimentation indicated that mock-up 01 did not present improvements in terms of wrist posture, but rather a better distribution of pressure in the palmar region. The ergonomic design/project revision turned up into two new mock-ups, 02 and 03, which presented (in the results of the third experimentation) a lower amplitude for movements and a better distribution of the percentage of time in the different pre-established ranges of amplitude, as well as in the pressure of the palmar region, mainly when mock-up 02 is concerned. Statistically meaningful differences (p < 0,05) were found only in the third experimentation, indicating that mock-ups 02 and 03 presented better performance. The results of the fourth experimentation indicated similar results from the physiological assessment, corroborating its results. Such procedures characterized a consistent alternative to the traditional methods for assessing and analyzing hand instruments in ergonomic design. / A usabilidade é um dos principais aspectos do desempenho e qualidade da interface mão/instrumentos, cuja aplicação baseia-se em metodologias de design ergonômico. Apesar da evolução tecnológica, alguns instrumentos manuais ainda não atendem aos critérios da usabilidade e podem gerar problemas ergonômicos em seus usuários. Um exemplo disso é o transdutor utilizado nas atividades ocupacionais da ultra-sonografia (US) de mama, o qual exige grandes esforços biomecânicos. Este estudo teve como objetivo propor um método de avaliação e análise, com base em registros fisiológicos e subjetivos, durante a aplicação de critérios de usabilidade no redesenho ergonômico do transdutor de US de mama. Para a realização dos registros fisiológicos, foi utilizado um eletrogoniômetro Biometrics, para análise dos movimentos do punho, e sensores FSRs para análise de pressão palmar. Para as avaliações subjetivas, foram aplicadas escalas gráficas de percepção. A coleta dos dados ocorreu em fases experimentais: Primeira experimentação - avaliação das posturas de punho durante simulação da atividade com dois modelos comerciais de transdutores (n = 18); Design ergonômico - aplicação dos critérios de usabilidade no redesenho e confecção de mock-up; Segunda experimentação - avaliação das posturas e pontos de pressão palmar, durante simulação da atividade com o novo mock-up e os transdutores comerciais (n = 10); Design ergonômico/Revisão projetual - revisão dos critérios de usabilidade e desenvolvimento de dois novos mockups; Terceira experimentação - avaliação de posturas e pontos de pressão palmar, durante simulação da atividade com os novos mock-ups e os transdutores comerciais (n= 10); Quarta experimentação - avaliação subjetiva de todos os transdutores (n = 11). Os resultados da Primeira experimentação demonstraram elevadas amplitudes médias e máximas. O Design ergonômico resultou no Mock-up 01. Os resultados da Segunda experimentação demonstraram que o Mock-up 01 não apresentou melhorias quanto a posturas de punho, mas uma melhor distribuição de pressão na região palmar. O Design ergonômico/Revisão projetual resultou em dois novos Mock-ups, 02 e 03, os quais apresentaram (nos resultados da terceira experimentação) uma menor amplitude de movimentos e uma melhor distribuição da porcentagem de tempo nas diferentes faixas de amplitude preestabelecidas, bem como da pressão na região palmar, principalmente quanto ao Mock-up 02. Diferenças estatisticamente significativas (p _ 0,05) foram encontradas somente na terceira experimentação, indicando em quais situações os Mock-up 02 e 03 apresentaram melhor desempenho. Os resultados da Quarta experimentação demonstraram o mesmo indicativo da avaliação fisiológica, corroborando seus resultados. Esses procedimentos caracterizaram um método de avaliação e análise de instrumentos manuais, expressivo e complementar para as metodologias de design ergonômico.
78

Uso da análise computacional de imagens ultra-sonográficas na avaliação da função luteal em bovinos / Use of computer-assisted ultrasound image analysis to evaluate bovine luteal function

Siqueira, Luiz Gustavo Bruno 27 February 2007 (has links)
Made available in DSpace on 2015-03-26T13:55:29Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2231606 bytes, checksum: b29196071c5e84791111ab5a3acb8e50 (MD5) Previous issue date: 2007-02-27 / Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Ultrasound image attributes, quantified by computer-assisted analysis, are a good indication of corpora lutea (CL) physiological and functional status. However, a standard method to capture and processing images has not been established for bovine. The purposes of this research were to establish a methodology for capture, processing and computer-assisted analysis; to evaluate CL morphological and echotexture changes throughout a natural estrous cycle or a luteolysis induced estrous cycle; and to determine whether computer-assisted analysis is efficient or not for embryo recipient selection. In the first study, evaluations were made of methods to capture images, systems of capture and the minimum representative sample area. For transrectal (TR) images, the minimum established area was 0.25 cm² (4.42% of the major area). A correlation was found in mean pixel values (r = 0.9930; P<0.001) and heterogeneity (r = 0.9861; P<0.001) between images videotaped or direct digitized. In a second study, two experiments were developed: natural estrous cycle and induced luteolysis (day 10) estrous cycle. Echotexture parameters of the CL, in the expt. 1, were analyzed after data adjustment to the onset of luteolysis. In both experiments, mean pixel values did not differ throughout the days of the cycle (P>0.10) and there was no correlation between plasma progesterone and mean pixel value (r = -0.39 and r = -0.28; P>0.10). Pixel heterogeneity varied through the days in a cycle with natural luteolysis (P<0.01), but did not in a luteolysis induced cycle (P>0.10). Correlations were observed between pixel heterogeneity and plasma P4 in both of the experiments (r = - 0.69 and r = -0.48; P<0.05). In a third study, embryo recipients (n=259) were examined by transrectal ultrasonography on the embryo transfer day (ET). The same type of analysis was done to assess image attributes, as previously tested in the 1st and 2nd studies. Good quality embryos (grades 1 and 2) collected after conventional superovulatory treatment (MOET; n=94) or in vitro produced (IVP; 88) were transferred to the recipients. Pregnancy rates were 56.4% and 30.2% for MOET and IVP, respectively. Plasma progesterone concentration values were greater in the recipients later diagnosed as pregnant, than in non-pregnant (5.88±0.77 vs 3.98±0.48 ng/mL, respectively; P<0.05). There was no difference in plasma P4 between pregnant and non pregnant IVP recipients (3.97±0.57 vs 3.52±0.23; P>0.10). Corpus luteum and luteal tissue area did not differ between pregnant and non-pregnant animals. In addition, no difference in mean pixel values (71.80±1.29 vs 71.19±1.14; P>0.10; scale of 0 to 255) and heterogeneity (14.80 vs 14.52; P>0.10) was observed, between pregnant and non pregnant MOET or IVP recipients. Echotexture parameters (mean pixel value and heterogeneity) showed correlations with plasma P4 (0.17 and 0.18, respectively; P<0.01). In conclusion, differences between capture, processing and image analysis methods should be considered in luteal echotexture evaluation; if on one hand, pixel heterogeneity in ultrasound images is a strong indicative of functional status and steroidogenic capacity of luteal gland, on the other hand, mean pixel values are a poor indicator of these characteristics. Finally, in this approach computer-assisted analysis of ultrasound images was not efficient on embryo recipient selection, probably due to other variables which strongly influence overall pregnancy rate. / Atributos de imagens de ultra-som, quantificados por análise computacional, têm o potencial de indicar o status fisiológico e funcional de corpos lúteos (CL). Ainda não foi estabelecido, contudo, um padrão de captura e processamento das imagens para bovinos. Os objetivos desta pesquisa foram estabelecer uma metodologia para aquisição, processamento e análise computacional de imagens; avaliar as mudanças morfológicas e de ecotextura do CL ao longo do ciclo estral natural ou após indução da luteólise; e verificar a eficiência da técnica de análise computacional na seleção e triagem de receptoras de embrião. No primeiro estudo, foram avaliados métodos de geração de imagens, sistemas de captura e área de amostragem mínima representativa. Para imagens geradas por via transretal (TR), a área mínima estabelecida foi de 0,25 cm² (4,42% de variação em relação à maior área). Foi constatada uma correlação nos valores médios de pixel (r=0,99; P<0,001) e heterogeneidade (r=0,99; P<0,001) entre imagens gravadas em fitas VHS e com digitalização direta. No segundo estudo, foram realizados dois experimentos: avaliação do ciclo natural ou após luteólise induzida no 10º dia do ciclo. No experimento 1, os parâmetros de ecotextura do CL foram analisados após o ajuste dos dados para o momento da luteólise. Em ambos os experimentos, o valor médio dos pixels não variou em função dos dias (P>0,10) e não foi observada relação entre a concentração de progesterona [P4] plasmática e este parâmetro (r = -0,39 e r = -0,28; P>0,10). A heterogeneidade variou em função dos dias na luteólise natural (P<0,01), mas não na induzida (P>0,10). Ainda, foram observadas relações entre heterogeneidade e a [P4] plasmática nos dois experimentos (r = -0,69 e r = -0,48; P<0,05). No terceiro estudo, receptoras de embrião (n=259) foram examinadas por ultra-sonografia no dia da transferência de embriões (TE). Foi feito o mesmo tipo de análise dos atributos das imagens previamente testado nos estudos 1 e 2. Foram transferidos embriões de boa qualidade (1 e 2) obtidos por superovulação convencional (TE; n=94) ou produzidos in vitro (PIV; n=88). As taxas de gestação foram de 56,4% e 30,2% para embriões TE e PIV, respectivamente. Nas receptoras TE, os valores de [P4] plasmática foram maiores nos animais posteriormente diagnosticados como gestantes que nos não gestantes (5,88±0,77 vs 3,98±0,48 ng/mL, respectivamente; P<0,05). No entanto, nas receptoras PIV não houve diferenças entre gestantes ou não (3,97±0,57 vs 3,52±0,23; P>0,10). A área do CL e área de tecido luteal entre gestantes e não gestantes não diferiu. Não foram observadas diferenças nos valores médios (71,80±1,29 vs 71,19±1,14; P>0,10; escala de 0 a 255) e na heterogeneidade (14,80 vs 14,52; P>0,10) dos pixels, em receptoras gestantes ou não gestantes, que receberam embriões TE ou PIV. Os parâmetros de ecotextura (média dos pixels e heterogeneidade) apresentaram baixas relações com a [P4] plasmática (0,17 e 0,18; respectivamente; P<0,01). Conclui-se que as diferenças nos métodos de captura, processamento e análise de imagens devem ser consideradas quando se avalia a ecotextura luteal; a heterogeneidade, ao contrário do valor médio, de pixels em imagens ultrasonográficas é indicativo de funcionalidade e capacidade esteroidogênica da glândula luteal; e a análise computacional de imagens não foi eficiente no auxílio à seleção e triagem de receptoras de embriões, possivelmente pela forte influência que outras variáveis exercem sobre a taxa de gestação final.
79

Efeitos da estimulação ultra-sônica pulsada e contínua no processo cicatricial de ratos submetidos à celiotomia / Pulsed and continuos ultrasound stimulation in rats healing celiotomy

Olsson, Débora Cristina 23 February 2005 (has links)
Made available in DSpace on 2016-12-08T16:24:03Z (GMT). No. of bitstreams: 1 PGCV05MA002.pdf: 1691913 bytes, checksum: 713d1f5baaea9131f22eecaf7a6e63bc (MD5) Previous issue date: 2005-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work two protocols of ultrasound therapy were used, in way continuous and pulsed, to evaluate the cicatrization of surgical wounds in mice submitted the celiotomy. Forty five female mice were used, rantomized in 3 experimental groups with 15 animals each group. The evaluation healing was accomplished by morphometry being evaluated the proportion size of the representatives tissue and cellular of samples of obtained tissues of the abdominal wall in time zero, 48, 96 and 144 hours after celiotomy. Twenty-four hours after the surgical intervention, the ultrasound application began on the surgical wound. The application of US in the pulsed way resulted larger proportion polymorphonuclear size, fibroblasts and angiogenesis at the 48 hours when compared with the group control and the group that it received ultrasound application in the continuous way (p 0,05). T hose resul ts suggest that the application of US in the pulsed way can be recommended in the treatment of surgical wounds in the abdominal cavity / Neste trabalho foram utilizados dois protocolos de ultra-som terapia, nos modos contínuo e pulsado, para avaliar a cicatrização de feridas cirúrgicas em ratos submetidos a celiotomia. Foram utilizados 45 ratos, fêmeas, separados aleatoriamente em 3 grupos experimentais com 15 animais por grupo. A avaliação da cicatrização foi realizada por esteriometria avaliando-se a proporção volumétrica dos constituintes tissulares e celulares de amostras de tecidos obtidos da parede abdominal às zero, 48, 96 e 144 horas após celiotomia. Vinte e quatro horas após a intervenção cirúrgica iniciou-se a aplicação de ultra-som sobre a ferida cirúrgica. A aplicação de US no modo pulsado determinou maior proporção volumétrica de polimorfonucleares, fibroblastos e angiogênese às 48 horas quando comparado com o grupo controle e o grupo que recebeu aplicação de ultra-som no modo contínuo (p 0,05). Esses resultados sugerem que aplicação de US, no modo pulsado pode ser recomendado como adjuvante no tratamento de feridas cirúrgicas na parede abdominal
80

Morfologia e sedimentologia dos recifes da plataforma continental externa norte do RN

Silva, Luzia Liniane do Nascimento 24 February 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-06-02T21:22:09Z No. of bitstreams: 1 LuziaLinianeDoNascimentoSilva_DISSERT.pdf: 11385354 bytes, checksum: 2d90e69f54674eb5848d7ade3b31a1f4 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-06-06T23:17:12Z (GMT) No. of bitstreams: 1 LuziaLinianeDoNascimentoSilva_DISSERT.pdf: 11385354 bytes, checksum: 2d90e69f54674eb5848d7ade3b31a1f4 (MD5) / Made available in DSpace on 2017-06-06T23:17:12Z (GMT). No. of bitstreams: 1 LuziaLinianeDoNascimentoSilva_DISSERT.pdf: 11385354 bytes, checksum: 2d90e69f54674eb5848d7ade3b31a1f4 (MD5) Previous issue date: 2017-02-24 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / A plataforma continental externa, setentrional do Rio Grande do Norte ? uma zona de transi??o fisiogr?fica, sedimentol?gica e de processos oceanogr?ficos marcada pelas varia??es eust?ticas do Quatern?rio. Neste estudo, n?s investigamos os ambientes recifais para entender a evolu??o geodin?mica da plataforma externa. Para tanto, o sonar de varredura lateral foi utilizado para mapear uma ?rea de 500 km?, entre os munic?pios de Macau e S?o Bento do Norte, paralelamente ? quebra da plataforma, al?m de 74 amostras sedimentares e da integra??o dos dados com fotografias subaqu?ticas e batimetria j? existentes para ?rea, a fim de validar as interpreta??es sonogr?ficas. Os principais objetivos deste trabalho s?o compreender como a geomorfologia antecedente da plataforma pode afetar o desenvolvimento dos recifes, e como os recifes se estabeleceram durante as varia??es holoc?ncias do n?vel do mar. Como resultados, foram identificados 7 padr?es de retroespalhamento (P1 a P7) associados a 11 f?ceis sedimentares (f?ceis biocl?sticas e silicicl?sticas), recifes distribu?dos em mont?culos, por vezes, orientados na dire??o NW-SE, e o paleovale do rio A?u. A f?cies areia biocl?stica com gr?nulos ? predominante, estando relacionada ao padr?o de retroespalhamento P6. Esta f?ceis ? respons?vel pela elevada porcentagem dos teores de mat?ria org?nica e carbonato da ?rea. Os recifes mapeados est?o situados em ?guas de 35 m de profundidade, e apresentam extens?o de dezenas a quil?metros de metros. ? poss?vel ver o alinhamento desses recifes em algumas regi?es, o que pode ser ind?cio de substratos antecedentes de antigas linhas de costa. Al?m disso, a fisiografia da plataforma em batentes e terra?os, a pouca sedimenta??o e as r?pidas varia??es do n?vel do mar no Holoceno controlaram a evolu??o dos recifes. / The outer continental shelf, northern Rio Grande do Norte is a zone of physiographic transition, sedimentological and oceanographic processes marked by eustatic variations of the Quaternary. In this study, we investigated the reef environments to understand the geodynamic evolution of the outer shelf. Therefore, the side scan sonar was used to map an area of 500 km?, between the municipalities of Macau and S?o Bento do Norte, in parallel with the shelf break, in addition to 74 sedimentary samples and and the integration of the data with underwater photographs and bathymetry already existent to the area, in order to validate the sonographic interpretations.The main aims of this study are to understand how the antecedent geomorphology of the shelf can affect the development of the reefs, and how the reefs settled during the sea level Holocene variations. As a result, 7 backscatter patterns (P1 to P7) were associated with 11 sedimentary faceis (bioclastic and siliciclastic faceis), reefs distributed in mounds, sometimes oriented in the NW-SE direction, and the paleovalley of the A?u river. The bioclastic sand facies with granules is predominant, being related to the backscatter pattern P6. This sedimentary faceis is responsible for the high percentage of the organic matter and carbonate contents of the area. The reefs mapped are located in waters of 35 m depth, and themselves extend from tens to kilometers of meters. It is possible to see the alignment of these reefs, mainly in the western region, which may be indicative of antecedent substrates of old coastlines. In addition, the physiography of the shelf on steps and terraces, low sedimentation and rapid variations in sea level in the Holocene controlled the evolution of reefs.

Page generated in 0.0404 seconds