Spelling suggestions: "subject:"dimensões.""
131 |
Impact of organized sports on risk of bone fracture among adolescents : ABCD - growth study /Lynch, Kyle Robinson. January 2018 (has links)
Orientador: Rômulo Araújo Fernandes / Banca: Fabio Augusto Barbieri / Banca: Dimitris Vlachopoulos / Resumo: Objetivo: Analisar o risco de fraturas traumáticas de acordo com o engajamento em esportes com diferentes níveis de impacto, assim como identificar o potencial impacto da participação esportiva nos gastos entre adolescentes. Métodos: Estudo longitudinal com 24 meses de seguimento. A amostra foi composta por 285 adolescentes de ambos os sexos (202 meninos e 83 meninas) que foram contatados pelos pesquisadores em escolas (n= 104) e clubes esportivos (n= 181) localizados na região metropolitana de Presidente Prudente, SP, Brasil. Todos os adolescentes foram convidados considerando os seguintes critérios de inclusão: a) idade entre 10-19 anos, 2) assinatura dos pais no termo de consentimento, 3) se contatados em clubes esportivos, pelo menos um ano de treino; se contatados na escola, pelo menos um ano sem prática esportiva ou exercícios. Os grupos foram classificados em: Controle (n= 104), Natação (n= 34), e Esportes de Impacto (n= 147). A ocorrência de fraturas e gastos em saúde foram avaliadas mensalmente durante 12 meses antes da linha de base e 12 meses após linha de base. Sexo, idade, composição corporal, participação esportiva, maturação biológica e proteína CReativa (PCR) foram avaliados durante os 12 meses após a linha de base. Análise estatística foi composta por teste Mann-Whitney, qui-quadrado, Regressão de Cox, Kruskal-Wallis, Analise de Covariância e medidas de tamanho de efeito. A significância estatística foi fixada em p<0.05 e todas as análises foram realizadas no... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: To analyze the risk of traumatic fractures according to the engagement in sports with different levels of physical impact, as well as to identify the potential impact of sports participation on health care costs among adolescents. Methods: Longitudinal study with 24 months of follow-up. The sample was composed of 285 adolescents of both sexes (202 boys and 83 girls) who were contacted by the researchers in schools (n= 104) and sports clubs (n= 181) located in the metropolitan region of Presidente Prudente, Sao Paulo, Brazil. All adolescents were invited, considering the inclusion criteria: 1) 10-19 years-old, 2) parents' consent form signed, 3) if contacted in any sports club, at least one year of training experience; if contacted in any school unit, at least one year without regular practice of sport or exercise. The groups were classified as: Control (n= 104), Swimming (n= 34), and Impact Sports (n= 147). The occurrence of fractures and health care costs were assessed monthly during the 12 months before baseline, as well as 12 months after baseline. Sex, age, body composition, sports participation, peak height velocity (PHV) and C-reactive protein (CRP) were assessed during the 12 months of follow-up. Statistical analyses were composed of Mann-Whitney test, chisquare test, Cox Regression, Kruskal-Wallis test, Analysis of Covariance and measures of effect size. Statistical significance was set at p<0.05 and all analyzes were performed using BioEstat software (vers... (Complete abstract click electronic access below) / Mestre
|
132 |
Desenvolvimento de sistema computacional para cálculo de propriedades elásticas e análises de tensão-deformação em compósitos laminados poliméricos / Development of a computational system for calculation of elastic properties and stress analysis of laminated polymer compositesGavassa, Daniela 28 October 2009 (has links)
Durante os últimos anos tem-se observado um aumento crescente no uso de materiais compósitos. Isto se deve principalmente devido às vantagens que os mesmos apresentam em relação aos materiais convencionais tais como: alta resistência e rigidez associado à elevado desempenho estrutural, baixo peso e boa resistência à corrosão e oxidação, dentre outros. Contudo, o uso de materiais compósitos em projetos estruturais exige um bom conhecimento de suas propriedades elásticas e ferramentas adequadas para análise de falhas destes materiais. Algumas ferramentas comerciais já foram desenvolvidas, entretanto estas ferramentas apresentam arquitetura fechada que, na maioria das vezes, não permitem implementações específicas para as necessidades de cada usuário. Este trabalho desenvolve um sistema computacional para cálculo de propriedades elásticas e estadas de tensão - deformação nas diferentes camadas de laminados poliméricos, utilizando plataforma JAVA em código aberto e de baixo custo. Após a entrada dos dados de materiais e seqüência das lâminas, o sistema calcula as propriedades elásticas bem como o estado de tensões e deformações nas diferentes camadas, propiciando assim a aplicação de diferentes critérios de falhas. O sistema foi validado em estudos de caso da literatura com resultados satisfatórios. / During the past years a growing increase in the use of composite materials has been observed. This is due mainly to the advantages they present in relation to conventional materials such as: high strength and stiffness associate with low weight, good resistance to corrosion and oxidation and others. However, the use of composites in structural applications demands a good knowledge of their elastic properties as well as computational tools for failure analysis of these materials. Some commercial tools have been already developed, however these packages do not allow specific users implementations. This work develops a computational system for calculation of elastic properties and stress analysis along the different layers of a polymeric laminate, using JAVA platform in open code with low cost. After the material data input and laminate sequence, the system calculates the elastic properties as well as the stress state in the different layers, thus allowing the application of different failure criteria.
|
133 |
Análise fotoelástica da distribuição de tensões em prótese fixa unitária posterior com conexões hexágono externo, hexágono interno e cone morse / Photoelastic stress analysis for implant-supported single fixed posterior crowns with external hexagon, internal hexagon and morse taper implant/abutment connectionsGonzález Esquerra, Martha Margarita 28 November 2014 (has links)
O objetivo deste estudo foi avaliar a distribuição de tensões na região peri-implantar de próteses fixas unitárias cimentadas com conexões protéticas em hexágono externo (HE), hexágono interno (HI) e cone morse (CM), substituindo o 2° pré-molar mandibular; utilizando análise fotoelástica. Foram confeccionados 3 modelos fotoelásticos com implantes de diferentes conexões protéticas (HE, HI e CM) suportando coroas metalocerâmicas unitárias, com dentes adjacentes (1° molar e 1° pré-molar mandibular). Foram aplicados 2 tipos de cargas com diferentes intensidades, oclusal fisiológica (15, 20 e 25 Kgf) e pontual (10 e 15 Kgf) na fossa mesial das coroas implantossuportadas. As imagens obtidas foram inseridas no programa Fringes® (Laboratório de Projetos Mecânicos, Universidade Federal de Uberlândia, Uberlândia, Brasil), e selecionados 12 pontos a serem analisados. Foram realizadas análises quantitativa e qualitativa das tensões observadas. Os resultados das tensões (KPa) medias da região peri-implantar, para cada tipo e intensidade de carga, foram: Cargas fisiológicas: 1) 15 Kgf: HE 107,42; HI 88,81; CM 182,63; 2) 20 Kgf: HE 185,60; HI 123,77; CM 226,44; e 3) 25 Kgf: HE 207,90; HI 176,88; CM 320,65; Cargas pontuais: 1) 10 Kgf: HE 115,94; HI 108,14; CM 64,78; e 2) 15 Kgf: HE 147,25; HI 143,88; CM 177,87. Foi observado que para os carregamentos fisiológicos a HI apresentou os menores valores de tensão e melhor distribuição entre implante e dentes adjacentes; a CM apresentou os maiores valores de tensão, contudo a distribuição entre implante e dentes adjacentes também foi adequada; a HE mostrou a distribuição menos favorável com tensões na crista mesial do implante. Nos carregamentos pontuais a CM apresentou melhor distribuição de tensões ao longo do implante seguido pela HI e HE. Conclui-se que a distribuição de tensões foi influenciada pelo tipo de conexão protética; sendo que as tensões foram melhor distribuídas na carga oclusal fisiológica. O HI apresentou melhor distribuição de tensões para a carga fisiológica e o CM para a carga pontual, evidenciando melhor desempenho das conexões internas / This study aimed to evaluate the peri-implant stress fields generated from 3 different implant- abutment interfaces external hexagon (EH), internal hexagon (IH) and morse taper (MT); supporting single crowns corresponding to the 2nd mandibular pré-molar via photoelastic analysis. 3 photoelastic models with different implant-abutment connections (HE, HI, CM) supporting metal-ceramic single crowns with adjacent teeth (mandibular 1st molar and 2nd pre-molar) were fabricated. The models were submitted to different loads: physiologic occlusion (15, 20, 25Kgf) and punctual (10, 15Kgf) in the implant-supported crown at the mesial fossa region. The images obtained were inserted in the software Fringes® (Laboratório de Projetos Mecânicos, Universidade Federal de Uberlândia, Uberlândia, Brasil). The maximum stresses were determined and observed at 12 selected points, qualitative and quantitative analysis were performed. The results of the stress (KPa) average of peri-implant regions with the 2 different loads and their respective intensities (Kgf) were: Physiologic occlusion: 1) 15 Kgf: HE 107,42; HI 88,81; CM 182,63; 2) 20 Kgf: HE 185,60; HI 123,77; CM 226,44; and 3) 25 Kgf: HE 207,90; HI 176,88; CM 320,65; Punctual loads: 1) 10 Kgf: HE 115,94; HI 108,14; CM 64,78; and 2) 15 Kgf: HE 147,25; HI 143,88; CM 177,87. With the physiological load the IH showed the lowest stress values and a favorable distribution among implant and adjacent teeth; the MT showed the highest stress values, however a favorable distribution with the adjacent teeth; the EH showed stress values in the cervical mesial point of the implant. For the punctual load the MT showed the best stress distribution within the implant, followed by the IH and EH. It was concluded that stress patterns were influenced by the connection design and were more favorable with the physiological occlusion load for all connections. The IH showed better stress distribution with the physiological occlusion load and the MT with the punctual load, showing better performance for internal connections
|
134 |
Análise fotoelástica de modelo de vértebra sob influência de parafuso pedicular / Photoelastic analysis of a vertebra model under the pedicular screw influenceSiqueira, Dayana Pousa Paiva de 01 February 2008 (has links)
O sistema de fixação vertebral utilizando o parafuso pedicular é um dos métodos mais eficientes no tratamento de patologias da coluna vertebral. Quando o parafuso estiver submetido à força de arrancamento, ele gera tensões ao redor, principalmente próximo do canal medular, situação que pode ser analisada pela técnica da fotoelasticidade. O objetivo foi analisar as tensões internas geradas em modelos fotoelásticos de vértebras, utilizando diferentes medidas de parafusos do sistema de fixação vertebral, submetidos à força de arrancamento. Foi utilizado um modelo de vértebra lombar em material fotoelástico utilizando três medidas de diâmetros externos de parafusos pediculares (5, 6 e 7mm) do tipo USS1. As tensões internas ao redor do parafuso foram avaliadas em 18 pontos pré-determinados utilizando um polariscópio de transmissão plana. As regiões de maiores concentrações de tensões foram observadas entre o canal medular e as curvas do processo transverso. Nas comparações das médias das tensões cisalhantes entre os parafusos 5 e 7mm, e 6 e 7mm foram observadas diferenças estatísticas significativas, o que não ocorreu com os parafusos de 5 e 6mm onde não foram observadas diferenças estatisticamente significativas. Foi observado que as tensões internas são mais elevadas em áreas irregulares próximas do canal medular, o que sugere ser uma região crítica, em termos de esforços mecânicos. / The system of vertebrae fixation using the pedicular screw is one of the most efficient methods to treat vertebral spine pathologies. When the screw is submitted to pullout strength, it causes internal stress near the medullary canal and this situation can be analyzed using the photoelasticity technique. The objective of this study was to examine the internal stress of a photoelastic vertebrae model using different sizes of screws for the vertebral fixation submitted to pulling out. A lumbar vertebral model made of photoelastic material with three different pedicular screw sizes (5, 6 and 7mm), type USS1 was used. The internal stress around the screw were tested in 18 pre established points by a plain transmission polariscope. The areas of greater concentration of stress were placed between the medullary canal and the transverse process. Comparing the maximum average pulling out stress, statistical differences were observed between screws 5 and 7, and 6 and 7. On the other hand, when screws 5 and 6mm where compared no significant differences were found. This study identified that the internal stress are greater in irregular areas, near the medullary canal, suggesting that this may be a critical region.
|
135 |
Avaliação das tensões geradas nos componentes protéticos de próteses obturadoras maxilares classe I, II e IV de Aramany por meio de análise de elementos finitos / Evaluation of stress generated in maxillar obturators prosthesis of class I, II and IV of Aramany in Finite Element AnalysisMiyashita, Elcio Ricardo 20 March 2013 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves sequelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de próteses obturadoras maxilares Classe I, II e IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 4.0 foi utilizado para a geração da malha de elementos finitos no programa Ansys Workbench 14.0®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores das próteses obturadoras, para observação das tensões geradas sobre as próteses obturadoras. Os resultados são apresentados sob a forma de análise qualitativa, indicada pelo estudo de Tensão Máxima Principal para as estruturas acrílicas da prótese e estudo de Von Mises para as estruturas metálicas da prótese, e análise quantitativa, representada por valores em Mega Pascal (MPa). Tanto nos carregamentos posteriores como nos carregamentos anteriores, foram observadas dissipações de cargas significativas localizadas na placa palatina próxima a ressecção e na junção do metal com o acrílico, sendo os maiores valores alcançados na placa de retenção metálica para retenção do acrílico localizada posteriormente na condição de carregamento posterior em ordem crescente na Classe II de Aramany com 149,17 MPa, Classe I de Aramany com 344,08 MPa e Classe IV de Aramany alcançando valor de 390,25 MPa. No acrílico da prótese obturadora, no caso de Classe I de Aramany em carregamento posterior, foi observada uma concentração de tensão principal na região correspondente ao limite lateral e anterior da junção da placa de retenção e do acrílico no valor de 19,796 MPa de tração. Na Classe IV de Aramany em carregamento posterior, foi observada uma concentração de tensão na região posterior da junção da placa de retenção e do acrílico no valor de 18,33 MPa. Na Classe II de Aramany, em carregamento posterior foi observada uma concentração de tensão na região anterior próxima ao limite da ressecção anterior no valor de 25,45 MPa de tração. Concluiu-se que os valores quantitativos alcançados neste estudo parecem não apresentar riscos de fratura sobre a armação metálica de liga de CrCo, porem podem apresentar riscos de falha na retenção metal/acrílico da prótese obturadora maxilar. A configuração de placa de recobrimento palatino proporciona uma melhor distribuição das tensões ao longo de sua superfície. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, determine the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class I,II andIV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 4.0 and then it was used to develop the finite element mesh in the software Ansys Workbench 14.0 ®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum stress and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that in the posterior loadings as in the anterior loadings were observed charge dissipation plate located in significant palate resection and near the junction of the metal with the acrylic and the highest values obtained in the metal retaining plate for retaining acrylic located further provided that subsequently loaded in ascending order in Class II Aramany with 149.17 MPa, Aramany with Class I and Class IV 344.08 MPa Aramany reaching value of 390.25 MPa. In acrylic prosthesis obturator in the case of Class I Aramany in subsequent loading, was observed a stress concentration in the region corresponding to the limit lateral and anterior junction of the retaining plate and the value of acrylic 19.796 MPa. Class IV for loading Aramany later, it was observed a stress concentration in the posterior region of the junction of the retaining plate of acrylic and the value of 18.336 MPa. In Class II Aramany in load was later observed a stress concentration in the anterior region near the boundary of the anterior resection worth 25.455 MPa. It was concluded that the quantitative values obtained in this study do not appear to present a risk of fracture of the metal frame CrCo alloy, but may present risks of failure in the metal retention / acrylic obturator prostesis . The configuration of palatal plate coating provides a better stress distribution along its surface.
|
136 |
Estudo da aplicação de ultrassom na medição de tensões em estruturas de concreto / Study of application of ultrasound to measure stresses in concrete structuresSchiavon, Karen Fernanda Bompan 22 June 2015 (has links)
Os ensaios não destrutivos visam avaliar um elemento sem gerar danos a ele com a técnica empregada. Um tipo de ensaio não destrutivo é o método da velocidade do pulso de ondas ultrassônicas. Este método é comumente utilizado para determinar propriedades elásticas de um dado material e verificar danos no interior dos elementos estudados. Outra aplicação do ultrassom é a medição do nível de tensão num material por meio da propagação das ondas ultrassônicas, tendo como base a teoria da acustoelasticidade. Entretanto, o uso do ultrassom para esta finalidade ainda é pouco difundido, principalmente na aplicação em estruturas de concreto. Este trabalho teve como objetivo estudar a possibilidade de medir tensões em estruturas de concreto com o uso do ultrassom. Para tanto, foram realizados ensaios de compressão uniaxial em prismas de concreto. Durante os ensaios, foram emitidas ondas ultrassônicas nos elementos para cada nível de tensão aplicada no material. A partir destes ensaios, foi feito um estudo do comportamento acustoelástico do concreto. Verificou-se que as velocidades das ondas ultrassônicas variaram em função da intensidade das tensões normais de compressão existentes nos corpos de prova. Com base na variação das velocidades, os coeficientes acustoelásticos do concreto de cada prisma foram determinados e relacionados com propriedades do concreto. Verificou-se a possibilidade de se estimar o nível mínimo de tensão em determinadas estruturas de concreto a partir do conhecimento de seus coeficientes acustoelásticos. Concluiu-se que é possível estimar tensões em estruturas de concreto utilizando o ultrassom. / Nondestructive tests aim to analyze an element generating no damages. The pulse velocity of ultrasonic waves method is a type of nondestructive test. This method is commonly used to determine elastic properties of materials and to verify damages inside studied elements. Another application for ultrasound is the measurement of stress level in a material by means of propagation of ultrasonic waves. This application is based on the theory of acoustoelasticity. However, the use of ultrasound is still unusual for this purpose, mainly in application in concrete structures. This work intended to study the possibility of measuring stresses in concrete structures with the use of ultrasound. Uniaxial compression tests were performed on concrete prisms. During tests, ultrasonic waves were propagated in elements for each level of applied stress in the material. Then, a study about acoustoelastic behavior of concrete was performed. It was verified that the velocities of ultrasonic waves changed according to the intensity of normal compressive stresses there were in the specimens. Based on the variation of velocities, the acoustoelastic coefficients of concrete were determined for each prism. The coefficients were related with properties of concrete. The possibility of estimating the minimum level of stress in certain structures of concrete from their acoustoelastic coefficients was verified. It was concluded it is possible to estimate stresses in concrete structures using ultrasound.
|
137 |
Aplicação da técnica da fotoelasticidade na análise de fundações por estacas helicoidais / Aplication of the photoelastic method to the analysis of helical screw pile foundationsSchiavon, José Antonio 23 July 2010 (has links)
A técnica da fotoelasticidade pode ser particularmente útil na análise de tensões em sistemas com geometrias complexas. Em um equipamento chamado polariscópio, um feixe de luz polarizada atravessa o modelo fotoelástico que representa o protótipo. Ao submeter este modelo a um carregamento, faixas de diferentes cores poderão ser visualizadas. Cada cor é associada a um nível de tensão. As tensões observadas no modelo fotoelástico podem ser comparadas com as tensões determinadas nos modelos numéricos ou analíticos. Em casos específicos, o problema da distribuição de tensões em uma fundação pode ser analisado com emprego da fotoelasticidade. A análise do comportamento de estacas helicoidais através da técnica da fotoelasticidade pode ser então de grande valia para estudos mais aprofundados deste sistema. O principal objetivo desta pesquisa foi viabilizar este método experimental para ser aplicado no Departamento de Geotecnia da EESC em análises de tensões em sistemas geotécnicos. Para validar as análises experimentais, tensões observadas em modelos de geometria simples foram comparadas com as tensões determinadas por meio de modelagem numérica com o método dos elementos finitos. O comportamento da fundação por estaca helicoidal observado pela técnica da fotoelasticidade mostrou semelhança ao observado na modelagem numérica. Por meio da distribuição de tensões, foi possível avaliar a influência da geometria helicoidal da lâmina e da profundidade de instalação da ancoragem no terreno. / The photoelastic method can be particularly useful for stress analysis with complex geometry systems. In equipment called polariscope, a polarized light beam crosses the photoelastic model that represents the prototype. Submitting this model to a load, fringes of different colors can be visualized. Each color is associated to a stress level. The stresses corresponding to the observed fringes on the photoelastic model can be compared to the stresses obtained through analytical or numerical models. In specific cases, the stress distribution problem can be analyzed with the use of photoelasticity. The photoelastic analysis of the helical pile behavior can then be valuable for further studies of this system. The main objective of this research was enabling this experimental method to be applied in the Department of Geotechnical Engineering of EESC in geotechnical systems stress analysis. To validate the experimental analysis, stresses observed in simple geometry models have been compared to those stresses determined by numerical modeling with the finite element method. The observed behavior of the helical pile foundation by photoelastic method showed similarity to that one observed through numerical modeling. Stress distribution analyses allowed evaluating the influence of helical blade geometry and the depth of installation.
|
138 |
Flexão e flexo-compressão em elementos de alvenaria estrutural / Bending and bending and compression at structural masonry elementsJoaquim, Mauricio Martinelli 28 May 1999 (has links)
Este trabalho trata da verificação e dimensionamento de peças de alvenaria estrutural submetidas à flexão. Inicialmente são apresentados os conceitos básicos do método das tensões admissíveis e são desenvolvidos procedimentos para a análise do problema da flexão simples e composta reta. Em seguida discute-se o problema da flexão composta oblíqua, com ênfase à modelagem computacional necessária ao desenvolvimento de aplicativos para a análise de seções genéricas. São apresentados na seqüência dois programas computacionais, implementados a partir dos algoritmos e procedimentos desenvolvidos nos itens anteriores. Apresentam-se ainda tabelas e ábacos que permitem o cálculo das peças de alvenaria com rapidez, facilidade e segurança, algumas das quais nos moldes das já tradicionalmente utilizadas para o concreto armado. Por fim, diversos exemplos são apresentados, ilustrando a teoria exposta e a utilização de tabelas e ábacos apresentados. / This study deals with the design of structural masonry pieces subjected to bending loads. At first, basic concepts of the allowable stresses method are presented and procedures for the analysis of simple bending and composed bending are developed. Next, the oblique composed bending is discussed emphasising computational modelling for the analysis of generic cross sections. Two computational procedures based on the algorithms already developed are also shown. In addition, tables and abaci that allow analysing the design of masonry elements quickly, easily and safely are presented. Some of them are very similar to those used for reinforced concrete. Finally, several examples are presented.
|
139 |
Povos indígenas e saúde mental: a luta pelo habitar sereno e confiado / Indigenous peoples and mental health: the struggle to live serene and trustingSousa, Flaviana Rodrigues de 15 May 2018 (has links)
Esta pesquisa empirica discute pontos de tensoes emergidos no dialogo interetnico em torno das questoes de saude indigena, dando enfase ao tema da saude mental. As tensoes foram analisadas segundo diferentes pontos de vista sobre a promocao da saude indigena, identificadas a partir da producao de um mapeamento que expressa os conteudos discursivos marcados por um grande divisor: de um lado a perspectiva ocidental, composta pelo Estado, compreendido atraves das Politicas Publicas de Saude Indigena; do Sistema Unico de Saude e sua assistencia a saude; pelos Conselhos Federal e Regional de Psicologia e pela Organizacao Mundial da Saude. Do outro lado esta a perspectiva dos indigenas, especialmente do povo Mbya Guarani, analisados com apoio da literatura antropologica, a partir da nocao de Teko Pora (Bem Viver); dos noticiarios produzidos e veiculados por coletivos indigenas; do conteudo narrativo contido no documentario Teko Rexa - Saude Guarani Mbya e dos discursos presentes nos noticiarios produzidos por entidades indigenistas. As nocoes de saude e saude mental discutidas por Gadamer (2006), bem como as nocoes de saude e de ethos refletidas por de Figueiredo (2008), referencial teorico-metodologico assumido nesta dissertacao fundamentam sobre a importancia do territorio nos processos de saude/doenca para os povos indigenas, bem como auxiliam a refletir sobre as tensoes presentes em ambas as perspectivas. Os dados foram analisados a partir da nocao de multiplicacao dialogica (Guimaraes, 2013) no ambito do construtivismo semiotico-cultural em psicologia. A partir da identificacao de tensoes presentes, foram levantadas questoes a respeito de como estruturar o cuidado em psicologia, refletindo sobre as possibilidades de seu transito entre diferentes perspectivas em saude / This empirical research discusses points of tension emerging in the interethnic dialogue around indigenous health issues, emphasizing the theme of Mental Health. The tensions were analyzed according to different points of view on the promotion of indigenous health, identified from the production of a mapping that expresses the discursive contents marked by a great divide: on the one hand the western perspective, composed by the State, understood through Policies Public Health Indigenous; of the Unified Health System and its health care; by the Federal and Regional Councils of Psychology; and the World Health Organization. On the other side is the perspective of the indigenous people, especially the Mbya Guarani people, analyzed with the support of anthropological literature, based on the notion of Teko Pora (Bem Viver); of the news produced and transmitted by indigenous collectives; of the narrative content contained in the documentary \"Teko Rexa - Saude Guarani Mbya\" and the speeches present in the news produced by indigenist entities. The notions of \"health\" and \"mental health\" discussed by Gadamer (2006), as well as the notions of \"health\" and \"ethos\" reflected by de Figueiredo (2008), theoretical and methodological reference assumed in this dissertation, importance of the territory in health / disease processes for indigenous peoples, as well as helping to reflect on the tensions present in both perspectives. The data were analyzed from the notion of dialogical multiplication (Guimaraes, 2013), within the scope of semiotic-cultural constructivism in psychology. From the identification of present tensions, questions were raised about how to structure care in psychology, reflecting on the possibilities of its transit between different perspectives in health
|
140 |
"Influência da nitretação a plasma no comportamento em fadiga dos aços inoxidáveis austeníticos AISI-SAE 304 e 316" / Plasma nitriding influence in the fatigue behaviour of austenitic stainless steels AlSl 304 and 316Manfrinato, Marcos Dorigão 31 August 2006 (has links)
Os aços inoxidáveis austeníticos são materiais atrativos para serem utilizados em vários setores industriais que operam sob meios corrosivos, como por exemplo: indústria química, alcooleira, petroquímica, de papel e celulose, na prospecção de petróleo e nas indústrias têxtil e farmacêutica. Contudo, apresentam propriedades tribológicas pobres. No sentido de melhorar essas propriedades, como aumentar a dureza superficial, a resistência ao desgaste e a resistência à fadiga, vários métodos de tratamentos superficiais vêm sendo utilizados. Dentre eles, o mais eficiente é a nitretação por plasma. Este processo é realizado em uma câmara de vácuo sob uma mistura gasosa de hidrogênio e nitrogênio. É aplicada uma diferença de potencial entre o cátodo (porta amostras) e o ânodo (paredes da câmara), acelerando os íons contra a superfície da peça, aquecendo-a e arrancando elétrons de sua superfície. Os íons reagem com espécies da superfície do plasma formando compostos instáveis do tipo FeN que se recombinam para formarem nitretos estáveis. O sucesso deste tratamento se deve à baixa temperatura de operação, ao menor tempo efetivo de tratamento e ao controle da uniformidade da espessura da camada. A camada de nitretos formada durante o tratamento possui uma influência positiva na vida em fadiga de um componente, graças a dois motivos principais. O primeiro é o atraso na nucleação da trinca devido ao aumento da resistência mecânica superficial. O segundo motivo está relacionado com a introdução de tensões residuais compressivas durante o processo de endurecimento da superfície, que retarda a iniciação da trinca e diminui o fator de intensidade de tensão. Os corpos de prova foram nitretados a 400ºC durante 6 horas, com uma pressão de 4,5 mbar e utilizando uma mistura gasosa de 80% vol.H2 e 20%vol.N2. Ocorreu um aumento da resistência mecânica próxima á superfície, devido à camada de nitretos, o que ficou evidente com o sensível aumento no valor do limite de fadiga do material nitretado em relação ao não nitretado. O limite de fadiga do aço AISI 316 não tratado foi de 400MPa e do nitretado foi de 510MPa, enquanto que, para o aço AISI 304, o limite de fadiga do material não tratado foi de 380MPa e o limite para material submetido ao tratamento de nitretação foi de 560MPa. / The austenitic stainless steels are attractive materials to many industrial sectors which work on corrosive environments, as chemical industry alcohol, petrochemical, cellulose industries, in the petroleum prospection and pharmaceutical and textiles industries. However, they present poor tribological properties. In order to improve these properties, like increasing superficial hardness, wear and fatigue resistance superficial heat treatment methods have being used. The most efficient is the plasma nitriding process which occurs in a vacuum container under hydrogen and nitrogen gas mixture. A potential difference is applied between the cathode (samples receptor) and the anode (container walls), accelerating the ions against the piece, heating it and removing electron from the surface of material. These atoms react with the surface plasma species, producing unstable compounds like FeN, which recombine producing stable nitrides. The success of this treatment is due to the low temperature operation, the short effective time of treatment and to the uniformity control of the layers thickness. The nitrides layer produced during the treatment have a positive influence in the fatigue life of a component, thanks to two main reasons. The first is the retardation in crack nucleation due to increasing of superficial mechanical strength. The second reason is due to introduction of compressive residual stress during the surface hardening process, which retards de crack initiation process. The specimens were nitriding at 400°C during 6 hours, at a 4,5mbar pressure and using a gas mixture of 80% vol. H2 and 20% vol. N2. The surface mechanical strength increased, due to the nitrides layer, which was evident with the sensitive increase in the fatigue limit of the nitriding specimens, comparing to the untreated ones. The fatigue limit of the AlSl 316 steel in untreated condition was 400 MPa and in nitriding condition was 510 MPa, whereas AlSl 304 steel, the fatigue limit of the untreated condition was 480 MPa and the fatigue limit for the nitrided condition was 560 MPa.
|
Page generated in 0.059 seconds