• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 106
  • 17
  • Tagged with
  • 123
  • 117
  • 57
  • 40
  • 40
  • 31
  • 24
  • 23
  • 23
  • 19
  • 18
  • 17
  • 16
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

[en] SHORT FATIGUE CRACKS DEPARTING FROM ELONGATED NOTCHED SPECIMENS AND THEIR EFFECT ON FATIGUE LIMIT / [pt] TRINCAS CURTAS DE FADIGA EMANANDO DA PONTA DE ENTALHES ALONGADOS E SEU EFEITO NO LIMITE DE FADIGA

MARCO VINICIO GUAMAN ALARCON 26 October 2017 (has links)
[pt] O projeto mecânico de componentes estruturais para vidas longas à fadiga requer limites de fadiga confiáveis. Porém, a previsão do limite de fadiga ainda apresenta alguns desafios, especialmente por causa dos inevitáveis entalhes e pela presença de pequenos defeitos intrínsecos do material que podem ser considerados como microtrincas. Os entalhes atuam como concentradores de tensão e microtrincas podem ser geradas na ponta destes. Tais microtrincas (geradas ou intrínsecas) podem propagar até provocar a falha do componente ou parar de propagar depois de crescer uma pequena distância e se tornarem não-propagantes, dependendo do nível de carga e do gradiente de tensão à frente do entalhe. Modelos empíricos e teóricos têm sido propostos para fazer previsão do limite de fadiga de componentes entalhados. Entre os teóricos, o chamado modelo do Gradiente de Tensão (GT), que utiliza conceitos da mecânica da fratura linear elástica, apresenta-se como um modelo promissor. No entanto, a validação experimental das previsões deste modelo ainda não tem sido completamente realizada. Neste contexto, corpos de prova tipo C(T) do aço 1020 e com vários valores do raio da ponta do entalhe foram testados sob controle de amplitude de carga constante, frequência de 40 Hz e razão de tensão R igual a 0.1 para avaliar o limite de fadiga através de testes acelerados com cargas tipo step up durante blocos de 3.10 elevado a sexta potência ciclos. O limite de fadiga determinado experimentalmente foi comparado com as previsões do modelo GT e do Método do Ponto, um dos métodos da chamada Teoria da Distância Crítica (TDC). No modelo GT foram considerados três métodos: GTc-p, GTs-e e GTquebra, segundo o método usado para achar o fator geométrico para determinar o fator de intensidade de tensão. As previsões dos modelos GTc-p, GTquebra e TDC são similares no caso de entalhes com raios de ponta grandes, e bem próximas do limite de fadiga medido experimentalmente, enquanto que eles são não-conservativos no caso de entalhes afiados (raios de ponta pequenos). As previsões do modelo GTs-e foram conservativas para entalhes afiados e não afiados. Devido a que os dois modelos são baseados em conceitos lineares elásticos, foi demonstrado que uma análise elástica apresenta limitações para modelar o comportamento à fadiga em entalhes afiados, pois nesses casos a tensão local no ponto crítico pode exceder o limite de escoamento do material. Alem disso, o modelo GT também permite estimar o tamanho da maior trinca curta não-propagante (TCNP) associada ao limite de fadiga. Tais TCNP foram monitoradas nas faces do C(T) através de técnicas não-destrutivas tais como microscopia óptica, correlação digital de imagens e tomografia; enquanto que as TCNP internas foram detectadas usando a técnica destrutiva da metalografia. Os tamanhos das TCNP detectadas foram muito menores do que as estimadas pelo modelo GT, dificultando ainda mais o problema de detecção daquelas trincas. / [en] The mechanical design of structural components for high cycle fatigue applications needs reliable fatigue limits. However, mainly because of notches and the unavoidable presence of small defects, such a task still presents some challenges. Notches cause a stress concentration effect that can initiate short cracks at their tips, but such short cracks may propagate or become non-propagating, depending not only on the load level, but on the stress gradient ahead of the notch tip as well. Notch-like defects, such as scratches, pores, and inclusions, behave in the same way. There are empirical and theoretical models to predict the fatigue limit of notched components. The latter includes the so-called Stress Gradient (SG) model, based on linear elastic fracture mechanics concepts and using the El Haddad-Topper-Smith (ETS) characteristic size aR, as a promissory approach. However, there is a lack of experimental data verifying their fatigue limit predictions. In this context, C(T)-like notched specimens of SAE 1020 steel with several notch root radii were tested under constant load amplitude control at 40 Hz and a stress ratio R equal 0.1, to evaluate their fatigue limit through accelerated tests involving step loading procedures with blocks of 3.10 to sixth power cycles. The experimental fatigue limit was compared with values predicted by SG model, following three approaches: SGc-p, SGs-e, and SGquebra, according to the determination of the geometric factor of the stress concentration factor; and with an alternative prediction by the Point Method based on the theory of critical-distance (TCD). SGc-p, SGquebra and TCD model predictions are almost coincident for blunt notches and they present a good agreement with experimental results, but they are non-conservatives in the case of sharp notches; while SGc-p predictions are conservative for both blunt and sharp notches. Since both models are based on linear elastic concepts, it was demonstrated that an elastic analysis presents limitations to model the behavior of short cracks emanating from sharp notches, due to the local stress at the critical point can exceed the yield strength of the material. Furthermore, according to SG model, the fatigue limit is related to the presence of non-propagating short cracks (NPSC). Such surface NPSCs on the face of the specimens were monitored by non-destructive techniques including optical microscopy, digital image correlation (DIC) and micro-computed tomography; whereas subsurface NPSCs were detected through destructive metallographic technique. The sizes of the detected NPSCs were much smaller than those values predicted by SG model, which in turn makes the detection of these cracks a more complex problem.
112

[en] FATIGUE CRACK PROPAGATION MODELLING BY ACCUMULATED DAMAGE INSIDE PLASTIC ZONE / [pt] MODELAGEM DA PROPAGAÇÃO DA TRINCA DE FADIGA ATRAVÉS DO DANO ACUMULADO NA ZONA PLÁSTICA

SAMUEL ELIAS FERREIRA 13 December 2018 (has links)
[pt] Após identificar que uma trinca de fadiga permanecia fechada durante parte do ciclo, Elber assumiu que o dano era induzido apenas pela fração do carregamento acima da carga necessária para abrir a trinca. Diversos modelos foram propostos utilizando o Delta Keff como força motriz da propagação, como os modelos da faixa plástica (strip-yield), que são amplamente utilizados para prever vida residual de componentes trincados. Embora o fenômeno do fechamento da trinca esteja provado, sua real importância na propagação da trinca de fadiga ainda é controversa. Outros mecanismos, além do fechamento da trinca, foram utilizados na tentativa de explicar os efeitos de sequência do carregamento na propagação em amplitude variável como o campo de tensão residual à frente da trinca. Mesmo após mais de 50 anos de pesquisas desde a proposição da primeira regra de propagação por Paris ainda não há consenso nem sobre o mecanismo nem sobre a modelagem. Esse trabalho tem como objetivo apresentar uma modelagem para prever propagação da trinca de fadiga com base na hipótese de que o dano acumulado por deformação plástica seria a força motriz para propagação. A modelagem proposta se diferença de outros modelos de acúmulo de dano por permitir que o contato existente entre as superfícies da trinca exerça influência sobre as deformações plástica à frente de sua ponta. Os resultados mostram que a modelagem proposta possui capacidade de reproduzir curvas de propagação semelhante ao modelo strip-yield. / [en] After identify that a fatigue crack remains closed during part of the load cycle, Elber assumed the damage was induced only by the cycle part over the load required to open the crack. Several models were developed based on Delta Keff as the strip-yield ones, which are widely used to predict residual lives of cracked components. Although the crack closure phenomenon is well proven its actual significance for the propagation is still controversial. Others mechanisms, beyond the crack closure, were used in trying to explain the sequence effects on variable amplitude crack propagation like the residual stress field ahead of the crack tip. However even after more than 50 years of research since the first propagation rule proposed by Paris there is no neither about the mechanism neither about modelling. This work has the aim of present a modelling to predict fatigue crack growth based on the hypothesis that the damage accumulated by cyclic plastic strain would be propagation the drive force. The modelling proposed differs from others damage accumulation models by allowing the existed contact between the crack surfaces to exercise its influence on plastic strain ahead of the crack tip. The results show that the proposed model is able to reproduce propagation curves similar to the model strip-yield.
113

[en] METROLOGICAL EVALUATION OF ZINC OXIDE VARISTORS OF MEDIUM VOLTAGE / [pt] AVALIAÇÃO METROLÓGICA DE VARISTORES DE ÓXIDO DE ZINCO PARA MÉDIA TENSÃO

FERNANDO ANTONIO TUPINAMBA BARBOSA 24 June 2005 (has links)
[pt] Apesar de seus muitos benefícios, uma das poucas desvantagens da tecnologia do semicondutor é a vulnerabilidade dos dispositivos de estado sólido à temperatura, sobretensões e sobre correntes. Mesmo os pulsos de tensão de energia muito baixos, podem produzir interferências e danos, às vezes com conseqüências de grande envergadura. Assim, enquanto a eletrônica é utilizada em mais e mais aplicações, a temperatura, a proteção contra sobretensão e a supressão de transientes transformam-se em fatores de suma importância para o desenvolvimento de um projeto. Os varistores provaram ser excelentes dispositivos protetores por causa da sua flexibilidade da aplicação e elevada confiabilidade. Os varistores do óxido do zinco (ZnO) são dispositivos eletrônicos de última geração, desenvolvidos para promover a proteção de circuitos elétricos contra a sobretensão, causada pelas descargas elétricas atmosféricas, tensões induzidas e manobras elétricas, e ideal para limitar a corrente de pico, bem como para absorver energia. O objetivo deste trabalho é propor uma metodologia para avaliação metrológica de varistores de óxido de zinco de média tensão, visando garantir o atendimento dos requisitos metrológicos para a proteção de circuitos elétricos, eletrônicos e de telecomunicações contra a sobretensão e supressão de transientes elétricos. Propõe-se ainda determinar a incerteza de medição dos parâmetros temperatura, tensão, corrente e resistência ôhmica de amostras comerciais de varistores de óxido de zinco. / [en] Despite its many benefits, one of the few disadvantages of semiconductor technology is the vulnerability of solid state devices to undesired increase in temperature, voltage and current . Even low voltage pulses can produce interference and damages with several consequences. Thus, as electronics are used in more and more applications, temperature, protection against surge and transient suppression are becoming factors of decisive importance in projects. Varistors have proven to be excellent protective devices due to their flexibility in applications and heightened trustworthiness. The zinc oxide varistors (ZnO) are state of the art electronic devices of last generation, developed to promote the protection of electric circuits against overvoltage, caused by atmospheric electric discharges, induced voltages and electric maneuvers, and suited to limit peak current, as well as absorbing energy. The purpose of this work is to propose a methodology for experimental characterization of zinc oxide varistors of average voltage, with the purpose of guarantee the attendance of the metrological requirements for protection of electric, electronic and telecommunication circuits against transient surges and suppression of electric transients. Uncertainty of measurement of the parameters temperature, voltage, current and ohmic resistance on commercial samples of zinc oxide varistors are also determined.
114

[pt] REOLOGIA DE OLEOS PARAFINICOS CRUS / [en] RHEOLOGY OF WAXY CRUDE OILS

10 November 2021 (has links)
[pt] Esta tese é sobre a reologia de óleos parafínicos crus. Um protocolo baseado na literatura relevante é desenvolvido para garantir que históricos térmico e de cisalhamento bem definidos sejam impostos em amostras que serão submetidas à medições reológicas. Com este protocolo, uma caracterização reológica quase completa de um óleo parafínico cru brasileiro é executada . Quatro experimentos reométricos são realizados, a saber, escoamento em estado estacionário, taxa de cisalhamento constante, tensão constante e rampa oscilatória de amplitude de tensão. Propriedades reológicas importantes, tais como, viscosidade, tensão limite de escoamento e módulos elástico e viscoso são medidos com o auxílio de técnicas diferentes em uma ampla faixa de condições. Além disso, uma comparação entre essas técnicas de medição é realizada. O processo de quebra da microestrutura do óleo parafínico brasileiro, assim como os efeitos na reologia do histórico do material e do tempo de repouso isotérmico são estudados. Fenômenos interessantes são observados, incluindo bifurcação da taxa de cisalhamento, dependência da tensão limite com os históricos térmico e de cisalhamento e independência dos resultados de regime permanente com relação à condição inicial após o resfriamento. Por fim, oportunidades para futuros desenvolvimentos e investigações são enfatizadas. / [en] This thesis deals with the rheology of waxy crude oils. A protocol based on the relevant literature is developed to guarantee well defined shear and thermal histories to waxy crude oil samples to be submitted to rheological measurements. With this protocol, a fair complete rheological characterization of a Brazilian waxy crude oil is performed. Four rheometric experiments, namely steady-state flow, constant shear rate, constant shear stress, and dynamic-stress-amplitude sweep are carried out. Important rheological properties, such as, viscosity, yield stress, and storage and loss moduli are measured with di↵erent techniques in a wide range of conditions and a comparison between the techniques is presented. The yielding as well as the history effects and the e↵ects of isothermal holding time on the microstructure and rheology of a Brazilian waxy crude oil are investigated. Interesting phenomena are observed, including bifurcation of shear rate, dependence of the yield stress with thermal and shear histories, and independence of the steady-state results with the post-cooling initial condition of the experiment. At last, opportunities for further developments are highlighted.
115

[en] LOCALLY STRESS-CONSTRAINED TOPOLOGY OPTIMIZATION WITH CONTINUOUSLY VARYING LOADING DIRECTION AND AMPLITUDE: TOWARD LARGE-SCALE PROBLEMS / [pt] OTIMIZAÇÃO TOPOLÓGICA COM RESTRIÇÕES LOCAIS DE TENSÃO E VARIAÇÃO CONTÍNUA DA DIREÇÃO E AMPLITUDE DO CARREGAMENTO: APLICAÇÕES EM PROBLEMAS DE GRANDE ESCALA

FERNANDO VASCONCELOS DA SENHORA 21 June 2022 (has links)
[pt] Otimização topológica (OT) é uma técnica de otimização estrutural capaz de gerar projetos incrivelmente detalhados para uma grande gama de problemas. No entanto, a maioria dos trabalhos de OT presentes na literatura está focada em problemas de minimização de flexibilidade, que não consideram a resistência dos materiais durante o processo de otimização, levando a soluções que não satisfazem limites de falha do material. Neste trabalho, focamos em problemas de OT baseados em tensão no qual introduzimos restrições de tensão no problema de otimização, para garantir a integridade estrutural do projeto final. A formulação de tensão de OT nos leva a um problema de engenharia muito mais natural que nos remete à seguinte pergunta: Qual a estrutura mais leve capaz de suportar as cargas as quais será submetida? Para ajudar a responder essa pergunta e para trazer a OT para mais próximo de aplicações reais, neste trabalho foi desenvolvido um sistema computacional em paralelo, baseado em GPU, considerando uma carga que pode variar a sua direção continuamente e capaz de resolver problemas de larga escala. A implementação em GPU apresenta soluções eficientes para os principais problemas de OT de larga escala, como o filtro, o algoritmo de otimização e a solução das equações de equilíbrio. Ao mesmo tempo, ao considerar uma carga variando continuamente que mais se aproxima das condições reais de carregamento usando uma estratégia de pior cenário, obtém-se soluções mais robustas e mais adequadas a aplicações de engenharia. Várias soluções numéricas são apresentadas, incluindo problemas 3D com mais de 45 milhões de restrições de tensão, que demonstram a efetividade das técnicas desenvolvidas neste trabalho. O sistema de larga escala baseado em GPU combinado com as soluções analíticas para a variação contínua de carga, tem o potencial de expandir o uso da OT na engenharia levando a novas e mais eficientes estruturas. / [en] In the field of structural optimization, Topology Optimization (TO) is one of the most general techniques because it is able to generate complex structures with intricate details for a wide range of problems. However, most of the works in TO have focused on compliance-based design that does not consider material strength in the design process leading to structures that do not satisfy material failure requirements. In this work, we focus on the stress-based design approach. We introduce stress constraints in the optimization procedure to guarantee the structural integrity of the final optimized design. This leads to a more natural formulation that addresses a simple engineering question: What is the lightest structure able to withstand its loads? We developed a large-scale GPU-based parallel stress-constrained TO framework considering a continuous range of varying load directions to answer this question and close the gap between TO and practical application. The developed GPU-based C++/CUDA framework efficiently addresses the main challenges of large-scale TO, filtering, optimization algorithm, and the solution of the equilibrium equations, only requiring a moderately affordable GPU hardware. At the same time, we obtain designs that are more suitable for engineering applications by considering a continuous variable range of load directions that more closely resemble real-life service loads using a worstcase analytical approach. We present several numerical results, including 3D problems with over 45 million local constraints providing detailed optimal structures that demonstrate the capabilities of the techniques developed in this work. The large-scale GPU framework, combined with the analytical solutions for continuously varying load cases, has the potential to expand the applications of TO techniques leading to improved engineering designs.
116

[en] METHODS BASED ON SYNCHRONIZED PHASOR MEASUREMENTS FOR VOLTAGE STABILITY MONITORING / [pt] MÉTODOS BASEADOS EM MEDIÇÕES FASORIAIS SINCRONIZADAS PARA O MONITORAMENTO DA ESTABILIDADE DE TENSÃO

DIOGO CARDOSO LIMA 03 December 2020 (has links)
[pt] O fenômeno associado à estabilidade de tensão se caracteriza pela existência de valores máximos de potência ativa e reativa que podem ser transferidas a uma barra de carga, ou injetada na rede através dos geradores e compensadores síncronos. Sua relevância para o setor elétrico é constantemente reforçada pelo registro de ocorrências de colapsos de tensão em diversos países do mundo e, embora a instabilidade de tensão manifeste-se localmente, suas consequências se refletem na ampla deterioração do sistema. Impulsionado pelo crescente interesse a respeito dos métodos baseados em medições fasoriais sincronizadas para a detecção do máximo carregamento, este trabalho apresenta os principais modelos encontrados na literatura baseados em medições locais e no vasto monitoramento do sistema, com maior ênfase aos métodos de Corsi-Taranto e Circuito Acoplado de Porta-Simples Aprimorado (CAPS Aprimorado). Algumas contribuições são sugeridas ao modelo CAPS Aprimorado tendo em vista sua aplicação ao conjunto de barras de transferência e de geração. Explora-se a utilização dos equivalentes multi-portas como índice de avaliação das condições de estabilidade de tensão, comparando a identificação da barra crítica aos métodos da matriz D e dos autovalores e autovetores. São evidenciadas as principais limitações dos modelos mediante a um conjunto de análises estáticas e dinâmicas, considerando diferentes cenários de carregamento, a sensibilidade dos modelos ao ruído e a resposta dos métodos em face da atuação dos limitadores de sobre-excitação. / [en] The voltage stability phenomenon is characterized by the existence of a maximum active and reactive power that can be transferred to a load bus or injected into the network through the generators and synchronous compensators. Its relevance to the electric power sector is constantly reinforced by the record of occurrences of voltage collapses in several countries around the world. Although the voltage instability manifests itself locally, its consequences is reflected in the wide deterioration of the system. Driven by growing interest in methods based on synchronized phasor measurements for maximum loadability detection, this work presents the main models found in the literature based on local measurements and wide area monitoring, emphasizing the Corsi-Taranto method and Improved Coupled Single-Port Circuit (Improved CAPS). Some contributions are suggested to the Improved CAPS model considering its application to the set of transit and controlled buses. The use of the multi-port equivalents is explored as the evaluation index of voltage stability conditions, comparing the identification of the critical bus to the D matrix method and eigenvalues and eigenvalues method. The main limitations of the models are demonstrated through a static and dynamic studies, as well different loading scenarios, the sensitivity of the models to the noise and the response of the methods when the over-excitation limiters are considered.
117

[es] ESTUDIO EXPERIMENTAL DEL RELAJAMIENTO DE UNA FIBRA SINTÉTICA DE ALTA RESISTENCIA / [pt] ESTUDO EXPERIMENTAL DA RELAXAÇÃO DE UMA FIBRA SINTÉTICA DE ALTA RESISTÊNCIA / [en] EXPERIMENTAL INVESTIGATION ON THE STRESS RELAXATION BEHAVIOR OF A HIGH-STRENGTH ARAMID FIBER

MARGARETH DA SILVA MAGALHAES 19 February 2001 (has links)
[pt] Neste trabalho é feito um estudo experimental da relaxação de uma fibra sintética de alta resistência, conhecida como Kevlar 49, empregada na fabricação de cabos que podem ser usados como cabos de protensão. O objetivo é obter uma equação para o cálculo da relaxação e verificar a influência de um condicionamento mecânico (aplicação e remoção de uma tensão). Foram realizados ensaios em seis amostras da fibra sob cinco níveis de tensão, equivalentes a 10%, 20%, 30%, 40% e 50% da tensão de ruptura do material. Os ensaios foram realizados com a temperatura e umidade relativa do ar controlados na faixa de 21oC + 2oC e 77% + 7% respectivamente. O tempo de duração de cada ensaio foi de 72 horas. Os resultados revelaram que as curvas de relaxação são lineares quando plotadas numa escala logarítmica do tempo e que o coeficiente de relaxação é bem representado por uma função potencial e depende da tensão aplicada. Em adição revelaram que um condicionamento mecânico não altera o comportamento da fibra. / [en] High-strength aramid fibers have been used in the production of a variety of cables and ropes which have found several applications as structural members in bridges and other types of structures. For such applications, a sound knowledge of the time dependent material properties is highly important. An experimental investigation on the stress relaxation behavior of a high-strength aramid fiber was carried out, with the purpose of studying the viscoelastic properties of the material and the effect of a mechanical conditioning (application and removal of stress prior to testing) on these properties. The fiber used in this investigation is commercially known as Kevlar 49. The tests were conducted at five different stress levels, at constant temperature and moisture. The results showed that the fiber has a non-linear viscoelastic behavior and that the effect of the mechanical conditioning isn´t important. An equation for the prediction of the stress relaxation is presented. / [es] En este trabajo se realiza un estudio experimental de la relajamiento de una fibra sintética de alta resistencia, conocida como Kevlar 49, empleada en la fabricación de cables que pueden ser usados como cables de protensión. El objetivo es obtener una ecuación para el cálculo dela relajamiento y verificar la influencia de un condicionamento mecánico. Fueron realizados ensayos en seis muestras de la fibra bajo cinco niveles de tensión, equivalentes a 10%, 20%, 30%, 40% y 50% de la tensión de ruptura del material. Los ensayos fueron realizados con la temperatura y la humedad relativa del aire controlados en la faja de 21oC + 2oC y 77% + 7% respectivamente. El tiempo de duración de cada ensayo fue de 72 horas. Los resultados revelaron que las curvas de relajamiento son lineales cuando se utiliza una escala logarítmica para el tiempo y que el coeficiente de relajamiento está bien representado por una función potencial, que depende de la tensión aplicada. Adicionalmente, los ensayos revelaron que un condicionamento mecánico no altera el comportamiento de la fibra.
118

[en] DESIGN AND DEVELOPMENT OF MEASUREMENT SYSTEM FOR IMPULSE VOLTAGE PUNCTURE TESTING ON INSULATORS / [pt] PROJETO E DESENVOLVIMENTO DE SISTEMA DE MEDIÇÃO PARA ENSAIOS DE IMPULSO DE PERFURAÇÃO EM ISOLADORES

IGHOR SOUZA DOS SANTOS 30 April 2020 (has links)
[pt] O ensaio de impulso para perfuração de isoladores é um ensaio normalizado descrito na IEC 61211:2004 e é fundamental para verificar em laboratório a qualidade de isoladores de vidro ou porcelana utilizados no sistema elétrico de potência. A norma IEC 60060-2:2010 recomenda que a calibração dos Sistemas de Medição utilizados em ensaios para Perfuração de Isoladores (SMIP) deve ser realizada por comparação com um padrão. Contudo, embora o ensaio de perfuração seja normalizado, ainda não existem padrões para rastrear esse sistema de medição na maioria dos institutos de pesquisas em âmbito global. Quantificar a amplitude de um impulso de perfuração, com todas as garantias metrológicas, não é uma tarefa trivial, por se tratar de um sinal impulsivo com amplitude de centenas de kilovolts e durações da ordem de 200 ns. Além disso, divisores de tensão com alto desempenho dinâmico para essa aplicação especifica também não estão disponíveis comercialmente. Deste modo, o objetivo desta dissertação foi projetar e desenvolver um SMIP. O divisor de tensão, integrante do sistema de medição, foi construído a fim de garantir uma mínima indutância e um alto desempenho dinâmico. Também foi desenvolvido um filtro para a remoção de interferências eletromagnéticas baseado na transformada wavelet, integrado a um software que controla aquisição, condicionamento do sinal, determinação e análise dos parâmetros do impulso de perfuração. O desempenho do sistema de medição foi avaliado em baixa tensão e em alta tensão, bem como foi estimada sua incerteza de medição, sendo então capaz de atender às exigências normativas e metrológicas do Laboratório de Referência em medição do Cepel. / [en] Impulse testing for puncture insulator is a standardized test described in IEC 61211:2004 and is essential for laboratory testing of the quality of glass or porcelain insulators used in the electrical power system. IEC 60060-2:2010 recommends that calibration of Measurement Systems used in Impulse Puncture Test on insulators (IPMS) should be performed by comparison against a standard. However, although the impulse puncture testing is standardized, there are still no standards for traceability of this measurement system at most research institutes globally. Quantifying the amplitude of an impulse puncture test, with all metrological guarantees, is not a trivial task, since it is an impulsive signal with amplitude of hundreds of kilovolts and durations of the order of 200 ns. In addition, high dynamic performance voltage dividers for this specific application are not commercially available either. Thus, the objective of this dissertation was to design and develop an IPMS. The voltage divider, which is part of the measuring system, is designed to ensure minimum inductance and high dynamic performance. A filter for electromagnetic interference removal based on the wavelet transform was also developed, integrated with software that controls acquisition, signal conditioning, determination and analysis of the impulse puncture testing parameters. The performance of the measuring system was evaluated at low voltage and high voltage, as well as its measurement uncertainty was estimated, being able to meet the normative and metrological requirements of the Cepel s Measurement Reference Laboratory.
119

[en] A LOAD MODELING METHODOLOGY FOR STEADY STATE AND DYNAMIC SIMULATIONS / [pt] UMA METODOLOGIA DE MODELAGEM DE CARGAS PARA SIMULAÇÕES EM REGIME PERMANENTE E DINÂMICAS

IGOR FERREIRA VISCONTI 21 May 2020 (has links)
[pt] Para simular, prever e controlar os sistemas de energia elétrica, engenheiros precisam de ferramentas computacionais para modelar os componentes dessa rede interconectada altamente complexa. Muitos esforços ao longo do século passado foram dedicados a desenvolver modelos matemáticos para geradores, linhas de transmissão, compensadores de potência reativa, transformadores e assim por diante. Os principais componentes dos sistemas de potência são representados precisamente através de modelos matemáticos, mas as cargas ainda são uma fonte de incerteza nas simulações, devido à sua característica de aleatoriedade. Modelos de carga conservadores superestimam a resposta de potência a desvios de tensão, enquanto modelos de carga excessivamente otimistas podem subestimar as margens de estabilidade, deixando o sistema muito próximo do seu limite operacional. É preciso estabelecer representações de cargas tão próximas da realidade quanto possível, a fim de explorar os recursos de rede de modo mais eficiente. Este trabalho fornece uma metodologia para modelagem de carga, investigando e resumindo as etapas do processo, que podem ser implementadas de diversas maneiras. O tratamento de dados, a escolha de uma representação matemática do modelo de carga e sua estimação de parâmetros são apresentados através de estudos de caso reais, tanto para uma aplicação focada na dinâmica do sistema elétrica, quanto para uma aplicação em regime permanente. Discute-se como otimização e conceitos de inferência estatística podem ser ferramentas efetivas para alcançar melhores aproximações sobre como a carga responderá a perturbações causadas por variações de tensão, sejam estas variações espontâneas, ou devido a ações de controle, ou causadas por curtos-circuitos. / [en] To simulate, predict and control Electric Power Systems (EPS), engineers need tools to model the components of this highly complex interconnected network. Many efforts over the past century were dedicated to develop mathematical models for generators, transmission lines, reactive power compensators, transformers and so on. The main components of the power systems are precisely represented by mathematical models, but the loads are still a source of uncertainty in the simulations, due to their random characteristics. It is well known that conservative load models super estimate power response to voltage deviations, and, on the other hand, over-optimistic load models may underestimate stability margins, leading a system to operate too close to its limit. It is necessary to stablish load representations as close to reality as possible, in order to fully exploit grid resources. This work provides a methodology for load modeling, investigating and summarizing the steps of the process, whose can be implemented in a wide variety of ways. Data treatment, the choice of a load model representation and their parameters estimation are presented through real case studies, both for dynamic simulation and a steady state application. It is discussed how optimization and statistical inference concepts can be effective tools to reach better approximations on how load will respond to disturbances caused by voltage variations, whether these were spontaneous, due to control actions, or caused by short-circuits.
120

[pt] MODELO DE TOLERÂNCIA ÀS TRINCAS CURTAS APLICADO A ANÁLISE ESTRUTURAL DE FRAGILIZAÇÃO PELO HIDROGÊNIO EM SISTEMAS DE SALMOURA CONTENDO H2S E HIDROGÊNIO GASOSO EM ALTA PRESSÃO / [en] TOLERANCE TO SHORT CRACK MODELING APPLIED TO THE STRUCTURAL ANALYSIS OF HYDROGEN EMBRITTLEMENT UNDER H2S BRINE SYSTEMS AND HIGH-PRESSURE GASEOUS HYDROGEN

RODRIGO VIEIRA LANDIM 10 October 2024 (has links)
[pt] O desenvolvimento de novas tecnologias com Hidrogênio como fonte de energia ressalta um antigo desafio nos meios de transporte e armazenamento desse, visto que todos materiais estruturais têm susceptibilidade a fragilização pelo hidrogênio. A forma usual de resolver esse problema é o uso de materiais nobres e mais resistentes a fragilização pelo hidrogênio. Uma alternativa para o dimensionamento mecânico em condições de fragilização pelo hidrogênio vem da modelagem de trincas curtas através da mecânica da fratura linear elástica ou Elasto-Plástica. Esses modelos consideram dois parâmetros do material, o Limite de Resistência ao Trincamento Assistido pelo Ambiente e o Limiar de Propagação de Trincas no meio. Nesse trabalho o modelo proposto é validado experimentalmente em condições de Corrosão sob Tensão Induzida por Sulfetos (aço de alta resistência e baixa liga e o aço inoxidável super martensítico UNS S41426 expostos ao sulfeto de hidrogênio), bem como o aço 17-4PH em 200bar(g) de H2. O método de teste T-WOL recomendado no código ASME BPVC para a obtenção da tenacidade à fratura sob alta pressão de H2 é avaliada para materiais com alta tenacidade, a qual não apresentou bons resultados. Como alternativa, uma metodologia modificada a partir da norma ASTM E1820 para obter a curva J-R em H2 a alta pressão é testada, obtendo o limiar de propagação de trincas em condições Elasto-Plásticas. Durante as atividades, uma célula de carga utilizada no interior da autoclave de teste falhou quando exposta a 200bar(g) de H2. Foi realizada análise de falha e redimensionamento, conforme o modelo de trincas curtas proposto, para que células semelhantes pudessem ser utilizadas nos testes subsequentes / [en] The development of new technologies with hydrogen as an energy source underscores a longstanding challenge in its transportation and storage, since all structural materials are susceptible to hydrogen embrittlement. The usual approach to solve this problem is to use nobler materials more resistant to hydrogen embrittlement. An alternative approach to mechanical design under hydrogen embrittlement conditions involves the modeling of the behavior of short cracks through linear elastic or elastoplastic fracture mechanics. These models consider two key material parameters: the Environmental Assisted Cracking Resistance Limit and the Crack Propagation Threshold in the environment. In this study, the proposed model is validated by suitable tests under sulfide stress corrosion cracking - High Strength and Low Alloy steel and a supermartensitic stainless steel UNS S41426 exposed to hydrogen sulfide, and in a 17-4PH steel exposed to high-pressure gaseous hydrogen, at 200 bar(g) of H2. A T-WOL test methodology recommended in ASME BPVC code for measuring the fracture toughness at high pressure of H2 for materials with high toughness is evaluated, and it yields unsatisfactory results. As an alternative, a modified ASTM E1820 test method is proposed to obtain the J-R curve under high-pressure H2, obtaining the crack propagation threshold at elastoplastic conditions. During these activities, a load cell used within the test autoclave failed when exposed to 200 bar(g) of H2. Failure analysis and a new design were conducted according the short crack tolerance model, to allow the use of similar load cells in the following tests.

Page generated in 0.0416 seconds