• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 4
  • 1
  • Tagged with
  • 12
  • 7
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Klimatkabinett : Komponenter och konstruktion

Ullbors, Anders January 2010 (has links)
<p>This report describes the construction of a climate-cabinet for testing of HV-cards (High Voltage) produced at VG Scienta. The main part of the report describes all the different components of the cabinet. The most important parts are a PID regulator from Eurotherm model 2408, a solid state contactor (SSC), a thermocouple, a finned resistor from DBK and different fans. The report even includes the connection between components by cable wiring, isolation, grounding, fuses and shaping of metal goods.</p><p>As the cabinet also communicates with a computer, the report includes the solution of the data communication using the software iTools from Eurotherm. The communication part includes information about a converter that converts EIA422 to USB.</p><p>The cabinet was produced at a company, called VG Scienta, in Uppsala during the spring 2010. The construction of an additional climate-cabinet was necessary because during the last year Scientas productivity increased, and it was important for the company to be able to manage the testing of an increased number of electronics.</p><p>Which solution is best for the heating of a cabinet? How does the communication work between a PC and a Eurotherm 2408 regulator? How to detect the temperature inside of the cabinet? These are some of the topics which are discussed.</p><p>The finished cabinet resembled the old cabinet in many ways. The difference between them is that the later one allows the testing of twice as many HV-cards, in an even more flexible way by the communication between the regulator and the computer. It means that the regulator parameters can be set continually and by programming it is possible to save the settings, the parameters and the curves.</p>
2

Klimatkabinett : Komponenter och konstruktion

Ullbors, Anders January 2010 (has links)
This report describes the construction of a climate-cabinet for testing of HV-cards (High Voltage) produced at VG Scienta. The main part of the report describes all the different components of the cabinet. The most important parts are a PID regulator from Eurotherm model 2408, a solid state contactor (SSC), a thermocouple, a finned resistor from DBK and different fans. The report even includes the connection between components by cable wiring, isolation, grounding, fuses and shaping of metal goods. As the cabinet also communicates with a computer, the report includes the solution of the data communication using the software iTools from Eurotherm. The communication part includes information about a converter that converts EIA422 to USB. The cabinet was produced at a company, called VG Scienta, in Uppsala during the spring 2010. The construction of an additional climate-cabinet was necessary because during the last year Scientas productivity increased, and it was important for the company to be able to manage the testing of an increased number of electronics. Which solution is best for the heating of a cabinet? How does the communication work between a PC and a Eurotherm 2408 regulator? How to detect the temperature inside of the cabinet? These are some of the topics which are discussed. The finished cabinet resembled the old cabinet in many ways. The difference between them is that the later one allows the testing of twice as many HV-cards, in an even more flexible way by the communication between the regulator and the computer. It means that the regulator parameters can be set continually and by programming it is possible to save the settings, the parameters and the curves.
3

Metoder för kartläggning av bränslebädd i rosterugn : framtagning av temperaturprofil &amp; undersökning av gasströmning / Methods of mapping the fuel bed of a grate fired oven : generation of temperature profile &amp; a gas flow study

Palmén, Carl, Olofsson, Per January 2012 (has links)
Metoder för analys av en bränslebädd i en biobränsleeldad rosterugn har utvecklats och utvärderats för att bedöma dess användbarhet. Dessa metoder omfattar framtagning av bränslebäddens utbredning, temperaturprofil och tryckfall genom bädden med hjälp av rostfria rör, termoelement, tryckmätare samt en laborationsuppställning. Metoderna producerade alla användbara resultat som gav snabb indikation på aktuella förhållanden.
4

Analys och korrelation av data från värmekamera

ALFEKY, AHMED January 2020 (has links)
The thesis is about seeing if there is any correlation between temperature deviation and selected variables to increase the understanding of what affects the camera. The work is an improvement method where R programs are used for mathematical solutions.  The methods used for this include data collection and scientific research. Based on the collected input data, the result could be obtained using these methods. An additional method was to connect two or more substances such as statistics and programming in a work where prior knowledge is used, the result is verified and the acquisition of knowledge continues.  The purpose was to use prior knowledge and software to see if there is any connection between input data that is on company’s database. The correlation between different variables is something that is used daily in society, industry and the international conventions. The correlation between two variables shows the extent to which they are related.  The result was obtained in the form of calculations, graphs and tables. There are indications that there is a weak correlation between camera angle and temperature deviation while there is a mean correlation between position and temperature deviation. There is a very weak correlation between holding times and temperature deviation, something that needs to be verified with several measuring points.  There are no definite results due to various factors such as the number of measuring points, although there are some indications that all camera angles except 25 ̊ can be a solution by performing several number of measuring points at both angles. The indication is largest for position in the camera's field of view. As for holding time, there is an indication that it does not affect the camera, but more measurements are needed to verify that indication.  The spread is also interesting. If the distribution is reasonably equal in the different cases, the position of the temperature deviation can always be adjusted with the aid of the emissivity.
5

En jämförande undersökning av helträelements värmeisoleringsförmåga

Petersson, Fredrik, Berggren, Oskar January 2009 (has links)
I drygt ett år har MHM-Scandinavia producerat massiva väggelement i Norden helt i trä. Detta är ett miljövänligt sätt att bygga på samtidigt som väggelementen har en god värmeisolerande förmåga. Genom att göra spår i lamellerna bildas luftkanaler inuti väggen som isolerar bättre än trä. Spåren gör att kontaktytorna mellan lamellerna blir mindre. Det medför att värmetransporten som i huvudsak sker genom ledning blir mindre och väggens värmeisolerande förmåga ökar.     Undersökningar av det massiva träelementets värmetransport är inte gjorda tidigare i Sverige. Vi har genom hjälpväggsmetoden jämfört tre olika typer av väggar. Väggarna har samma konstruktion fast med små avvikelser när det gäller luftkanalernas andel i lamellerna. Väggelementen är uppbyggda av korslagda lameller och förändringarna som gjorts i två av väggtyperna är endast utförda i de horisontella lamellerna.     Mätningarna indikerar att ju mindre kontaktytor och mer luft som finns i väggen desto bättre värmeisolerande förmåga.
6

En jämförande undersökning av helträelements värmeisoleringsförmåga

Petersson, Fredrik, Berggren, Oskar January 2009 (has links)
<p>I drygt ett år har MHM-Scandinavia producerat massiva väggelement i Norden helt i trä. Detta är ett miljövänligt sätt att bygga på samtidigt som väggelementen har en god värmeisolerande förmåga. Genom att göra spår i lamellerna bildas luftkanaler inuti väggen som isolerar bättre än trä. Spåren gör att kontaktytorna mellan lamellerna blir mindre. Det medför att värmetransporten som i huvudsak sker genom ledning blir mindre och väggens värmeisolerande förmåga ökar.     Undersökningar av det massiva träelementets värmetransport är inte gjorda tidigare i Sverige. Vi har genom hjälpväggsmetoden jämfört tre olika typer av väggar. Väggarna har samma konstruktion fast med små avvikelser när det gäller luftkanalernas andel i lamellerna. Väggelementen är uppbyggda av korslagda lameller och förändringarna som gjorts i två av väggtyperna är endast utförda i de horisontella lamellerna.     Mätningarna indikerar att ju mindre kontaktytor och mer luft som finns i väggen desto bättre värmeisolerande förmåga.</p>
7

Design of a Carbon Fiber Thermocouple for Elevated Temperature Measurements

Holmström, Marcus January 2020 (has links)
Thermocouples are one of the most commonly used instruments for thermometry at elevated  temperatures. As of today, there are only a few types of thermocouples that are built to withstand a temperature beyond 1600 °C,however they usually have a temperature measurement uncertainty of around 1% at these high temperatures. Beyond the 1600 °C temperature span, most high temperature thermocouples tend to drift in the measurements, causing it to output a faulty and inaccurate read of the actual temperature. This thesis explores the usage of carbon fibers as a material to be used in thermocouples, by the combination of two dissimilar carbon fibers. Polyacrylonitrile (PAN) and rayon based fibers were used up to a temperature of 200 °C, where the output voltage of the thermocouple was logged. The study shows a promising and stable linear output of the electromotive force for this type of thermocouple using commercially available carbon fibers at lower temperatures. A comparison is made between the commonly used thermocouples type K and S, results shows that the carbon thermocouple have around 21% of the thermoelectrical efficiency of that of a type K or S thermocouple at 25 °C. For the case of its functionality at higher temperatures, similar graphite material has been studied through literature and found a potential increase in the thermoelectrical stability at higher temperatures beyond 2000 °C, which show that carbon-based thermocouples are well suited for high temperature measurements. / Termoelement är ett av de mest använda instrumenten för temperaturavläsning vid upphöjda temperaturer. Idag finns det bara några få typer av termoelement som är byggda för temperaturer över 1600 ℃, däremot innehar dom vanligtvis en temperaturmätnings osäkerhet på cirka 1% vid dessa höga temperaturer. Över 1600 ℃ temperaturintervallet har de flesta högtemperatur termoelement en tendens att skifta i mätningarna vilket orsakar en felaktig och inexakt mätning av den faktiska temperaturen. Denna avhandling undersöker användningen av kolfiber som ett material för användning i termoelement, genom kombinationen av två olika grafitfibrer. Polyacrylonitrile- (PAN) och Rayon-baserade fibrer användes i en sammansatt kombination upp till en temperatur av 200 ℃, där spänningen mättes mot temperaturen. Studien visar en lovande och stabil linjär effekt av dess elektromotoriska spänning för denna typ av termoelement med kommersiellt tillgängliga kolfibrer vid lägre temperaturer. En jämförelse görs mellan de vanliga termoelementen av typ K och S vid rumstemperaturer, resultaten visar att grafittermoelementen har cirka 21% av den termoelektriska effektiviteten hos den för en typ K eller S termoelement vid 25 ℃. När det gäller dess funktionalitet vid högre temperaturer har liknande grafitmaterial studerats och funnit en potentiell ökning av den termoelektriska stabiliteten vid högre temperaturer över 2000 ℃, vilket visar att grafitbaserade termoelement gör sig väl lämpade för högtemperaturmätningar.
8

Cooling Strategy Influence on Temperature in ETD Center

Edinger, Oskar January 2021 (has links)
Striving for increased productivity while maintaining hole quality and high process robustness when drilling requires knowledge about the working principles of heat generation, mechanics and a proper cutting fluid that aids in cooling, lubricating and evacuating chips from the cutting zone. If the heat generated in the tool-workpiece and tool-chip interfaces does not exit the cutting zone adequately through the chips, the workpiece material or the redistribution of coolant the hole quality can be impacted negatively and breakdowns may occur which reduces overall productivity. During product testing, a sudden type of drill failure was observed when machining 316L stainless steel. When modifying the coolant design this was avoided which led to the assumption that the failure was caused by a large amount of heat being generated due to poor conductivity in the material combined with insuffcient cooling. However, this theory couldn't be investigated because of a lack of an existing method. To evaluate, three modifications of the CoroDrill 870 with dimensions Ø16mm and length 3xD were designed using Siemens NX 12 to observe whether coolant design choices have a significant impact on heat generation when drilling. To examine this a testing methodology was developed which utilizes IR-thermography and a combination of type K and J thermocouples inserted into the workpiece and onto the back surface, which measures its temperature in the cutting zone. Several tests were conducted with the developed setup to gather a larger data set to reduce impact from random error and to perform further analysis. Although the experiment setup is promising due to being simple and applicable to different materials there are large sources of variation associated with the placement of thermocouples. The results indicate some difference in registered temperature between the modifications however it is diffcult to draw conclusions based on the relatively few trustworthy measurements made. / För att förbättra produktiviteten vid borrning utan att kompromissa på hålkvalité och processäkerhet krävs bakomliggande kunskaper inom områden som, värmebildning, skärförlopp, och kylvätska vilket kyler, smörjer, och transporterar spånor från skärzonen. Om värmen som bildas i ytorna mellan verktyg-ämne och verktyg-spåna inte lämnar skärzonen på ett tillförlitligt sätt genom spånor, ämnet eller genom kylvätskans cirkulation kan hålkvalitén påverkas eller haverier kan orsakas vilket minskar produktivitet. Under en testning som genomfördes där 316L rostfritt stål borrades upptäcktes en ny typ av abrupt brott. När borrens kyllösning modiferades kunde detta fel undvikas varpå man drog slutsatsen att haveriet var en konsekvens av den stora temperaturgradient som bildas då materialets värmeledningsförmåga är relativt dålig. Dessvärre kunde denna teori inte prövas då det saknades en befintlig testmetodik. För att undersöka detta utvecklades tre modifikationer av CoroDrill 870 med dimension Ø16mm och längd 3xD i Siemens NX 12 i syfte att observera huruvida en signifikant temperaturskillnad skulle uppstå. För att utreda detta skapades en testuppställning som kombinerar IR-termografi med termoelement av typ K och typ J, fästa i ämnet respektive påämnets baksida vilket mäter materialets temperatur i skärzon. Ett flertal tester genomfördes med denna uppställning för att samla en större mängd data för fortsatt analys samt för att minska inverkan av slumpmässiga fel.Även om metoden är lovande då den är relativt enkel och tillämpbar på olika material så finns det stora potentiella källor till variation kopplade till mänsklig faktor och placering av termoelement. Resultatet som analyserats antyder att det finns en viss temperaturskillnad mellan modifikationerna men för att göra välgrundade slutsatser skulle fler mätningar behöva genomföras.
9

Optimalizace pohybu termoelektrického lineárního aktuátoru / Movement optimization of the thermoelectric linear actuator

Belháč, Jakub January 2011 (has links)
The thesis describes movement optimization of a linear thermoelectric actuator that is used for operating floor heating valves in modern buildings. Featuring experimental nature, the thesis deals with a problem specified by an industrial company within the following steps; definition of possible solutions based on problem research, experimental verification of selected propositions, the best solution selection resulting from the analysis of executed measurements, final verification with all product versions, benchmarking.
10

Temperature sensing on a linear wear test rig for plastic components / Temperaturmätning på en linjär testrigg gjord för nötning av plastkomponenter

Grahn, Anton, Granlund, Sebastian January 2022 (has links)
För att verifiera att komponenter håller under en förväntad livslängd kan en Accelererad Livstids Testning (ALT) användas. En av huvudaspekterna som kan förstöra ett ALT-test av plastkomponenter är om kontakttemperaturen överstiger glasövergångstemperaturen. Detta eftersom det förändrar testkomponentens materialegenskaper. För att förhindra att detta inträffar i en ALT byggdes en testrigg medtemperatursensorer för att övervaka kontakttemperaturen. Om kontaktpunkten modifieras med en temperatursensor förändrar det uppbyggnaden av ytan och gör testet ogiltigt. Metoden som används är istället att mäta temperaturen på ytan på testdelen och simulera kontakttemperaturen med en modell baserad på den Finita Elementmetoden. Denna avhandling jämför de två teknikerna Tunn Film RTD och Tunn Termoelement Tråd Typ T i samband med uppbyggnaden av en värmeöverföring FEM-modell. Det undersöktes också vilken teknologi av IR-enpunkts sensor och Tunn Film RTD som har högst prestanda med avseende på fyra kvalitetsparametrar under användning tillsammans med testriggen. Slutsatserna är att Tunn Film RTD och Tunn Termoelement Tråd av Typ T sensorerna båda ger en liknande precision i mätningar för att bygga en användbar FEM-modell. När de används på testriggen presterar Film RTD:n är bättre än IR-sensorn i tre av fyra områden med avseende på de fyra definierade kvalitetsparametrarna. Tunn Film RTD är den rekommenderade teknologin för denna typ av mätning. / To verify that components last for an expected lifetime an Accelerated Life Testing (ALT) can be used. One of the main aspects that can ruin an ALT of plastic components is if the contact temperature rises above the glass transition temperature, since this changes the material properties of the tested component. To prevent this from occurring in a ALT, a test rig was built with temperature sensors to monitor this contact temperature. If the contact point is modified with a temperature sensor, this will change the surface and make the test invalid. The method is instead to couple surface temperature measurements with a Finite Element Model (FEM) to estimate the contact temperature. This thesis compares the two techniques Thin Film RTD and Thin Thermocouple Wire Type T in conjunction with the building of a heat transfer Finite Element Method (FEM)-model. It also investigates which technology of Non Contact IR Single Point sensor or Thin Film RTD have the highest performance in use with the test rig with regard to four quality parameters. The conclusions are that RTD and the Thermocouple Type T sensors both provide equal precision in measurement to build a useful FEM model. In application on the test rig, the Thin Film RTD is better than the Infrared (IR)-sensor in three out of four areas when compared in the four defined quality parameters. Thin Film RTD is the recommended technology in this application.

Page generated in 0.0791 seconds