• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 10
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 43
  • 10
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Suivi par élastographie ultrasonore après réparation endovasculaire d’anévrisme aorto-iliaque : étude de faisabilité in vivo

Bertrand-Grenier, Antony 12 1900 (has links)
No description available.
42

Caractérisation de caillots sanguins par méthodes ultrasonores

Bosio, Guillaume 12 1900 (has links)
Les caillots sanguins sont responsables de nombreuses pathologies, telles que les thromboses veineuses profondes (TVP), les embolies pulmonaires (EP) ou les accidents vasculaires cérébraux (AVC). La thromboembolie veineuse, regroupant les thromboses veineuses profondes et les embolies pulmonaires, ainsi que les accidents vasculaires cérébraux sont parmi les principales causes de décès. La formation d’un caillot sanguin survient suite à une lésion de la paroi endothéliale, d’un changement hémodynamique de l’écoulement sanguin ou de conditions d’hypercoagulation du sang. Lors de situations pathologiques, le caillot ne se dissout pas naturellement et des anticoagulants sont prescrits. Leur but est d’empêcher l’évolution du caillot et de prévenir des risques de récidives. Dans le cas d’un accident vasculaire cérébral ou de certaines embolies pulmonaires, de l'activateur tissulaire du plasminogène recombinant (rt-PA) peut être prescrit pour dissoudre directement le caillot. Ces traitements comportent des risques d’hémorragie interne, et une incertitude persiste encore sur leur durée d’administration. La caractérisation des caillots sanguins vise à mieux comprendre leur développement pour pouvoir adapter les traitements et potentiellement à confirmer leur effet. Un moyen de caractériser les tissus est d’utiliser des méthodes ultrasonores. L’élastographie, une de ces méthodes, permet de calculer la rigidité d’un tissu, caractérisé par son module d’Young. On appelle élastographie dynamique les méthodes d’élastographie basées sur la propagation d’ondes de cisaillement dans le tissu pour calculer son module d’Young (relié à la vitesse de l’onde). Plusieurs études ont montré que le module d’Young de caillots sanguins augmentait avec le temps et que des caillots plus vieux et plus denses étaient plus résistants à la dissolution. La dispersion de l’onde de cisaillement reliée à la contribution visqueuse du tissu est un paramètre nouvellement disponible sur certains échographes cliniques qui est peu étudié dans le cadre des caillots sanguins. L’atténuation de l’onde de cisaillement est également un paramètre acoustique, non explorée dans le cas des caillots sanguins. L’utilisation de l’atténuation de l’onde de cisaillement a montré des résultats encourageant en simulations et sur fantômes. Cependant, avec les méthodes actuelles, le calcul de l’atténuation d’onde de cisaillement suppose un milieu homogène ne favorisant pas la présence de résonances acoustiques, ce qui n’est pas le cas pour des caillots cylindriques dans des vaisseaux sanguins. L’enveloppe ultrasonore peut également être étudiée de manière statistique et les paramètres issus de ces statistiques reflètent la microstructure des tissus imagés. L’objectif général de cette thèse est de caractériser les caillots sanguins pendant leur évolution à l’aide des différents paramètres découlant des ultrasons. Cette caractérisation vise à permettre aux soignants d’adapter l’administration du traitement. Un autre objectif consiste à évaluer l’effet du traitement sur les différents paramètres ultrasonores afin d’attester son efficacité. Pour réaliser ces objectifs l’étude se sépare en trois parties. La première partie est une étude in vivo en partenariat avec le centre hospitalier universitaire de Grenoble qui vise à étudier le module d’Young et les paramètres d’ultrasons statistiques au cours du temps chez des patients présentant des thromboses veineuses profondes. Les patients étaient sous anticoagulants ; le module d’Young n’a pas montré de changement significatif entre les mesures aux jours 0, 7 et 30. Les paramètres statistiques (étudiés suivant la distribution statistique homodyne K) ont montré une augmentation de l’intensité des rétrodiffuseurs (probablement liée à une augmentation du nombre de brins de fibrine et/ou du nombre de globules rouges) et une désorganisation des rétrodiffuseurs. Une des conclusions est que les paramètres statistiques pourraient permettre d’améliorer la caractérisation de caillots sanguins même quand le module d’Young ne varie pas significativement. La deuxième partie se concentre sur l’analyse du phénomène de résonance acoustique présent lors du passage d’ondes de cisaillement dans le caillot. Le but était de trouver une région d’intérêt où le calcul de l’atténuation de l’onde de cisaillement présente le moins de variation associée à ce phénomène. Les paramètres liés à la résonance, le module d’Young, la dispersion et l’atténuation de l’onde de cisaillement ont pu être reportés dans des fantômes de différents diamètres ainsi que dans des caillots in vitro pendant leur coagulation. Une région d’intérêt minimisant la résonance lors du calcul de l’atténuation de l’onde de cisaillement a pu être trouvée. La troisième étude porte sur l’effet de traitement avec du rt-PA sur le module d’Young, la dispersion de l’onde de cisaillement, l’atténuation de l’onde de cisaillement et les paramètres d’ultrasons statistiques. Du sang de porc a été collecté et 3 caillots par échantillon ont été préparés, chacun subissant une condition différente de traitement (pas de traitement, traitement à 20 minutes après le début de la coagulation et traitement à 60 minutes après cette phase initiale). Les résultats montrent que le module d’Young diminue significativement avec l’ajout du traitement, la dispersion de l’onde de cisaillement augmente pour les caillots traités à 60 minutes comparés à ceux non traités, l’atténuation de l’onde de cisaillement augmente pour les caillots traités à 20 minutes comparés à ceux non traités et l’intensité des rétrodiffuseurs diminue significativement dans les deux conditions de traitement. Ces paramètres pourraient aider à confirmer l’effet du traitement et déceler si des patients y sont résistants ou non. Cette thèse a permis une meilleure compréhension des propriétés mécaniques et acoustiques des caillots sanguins au cours de la coagulation et en fonction de traitements. Tout ceci constitue autant de propriétés qui pourraient être utilisées afin d’adapter la dose et la durée d’un traitement afin de réduire les effets secondaires lors de la prise en charge des patients. / Blood clots are the cause of numerous pathologies, including deep vein thrombosis (DVT), pulmonary embolism (PE) and stroke. Venous thromboembolism, which includes deep vein thrombosis and pulmonary embolism, and stroke are among the leading causes of death. Blood clots form as a result of damage to the endothelial lining, hemodynamic changes in blood flow or hypercoagulable blood conditions. In pathological situations, the clot does not dissolve naturally, and anticoagulants are prescribed. Their purpose is to prevent the clot from progressing and to reduce the risk of recurrence. In the case of stroke or certain pulmonary embolisms, recombinant tissue plasminogen activator (rt-PA) may be prescribed to dissolve the clot. While these treatments can be effective, they do pose a risk of causing internal bleeding, and there is currently uncertainty regarding the optimal duration for administering them. Blood clot characterization aims to better understand how blood clots develop, so as to be able to adapt treatments and potentially confirm their effect. One way of characterizing tissues is to use ultrasound methods. Elastography, one such method, calculates the stiffness of a tissue characterized by its Young's modulus. Elastography methods based on shear wave propagation in a tissue to calculate the Young's modulus (related to the wave velocity) are known as dynamic elastography approaches. Several studies have shown that the Young's modulus of blood clots increases with time, and that older and denser clots are more resistant to dissolution. Shear wave dispersion related to the viscous contribution of a tissue is a newly available parameter on some clinical ultrasound scanners. However, little is known in the context of blood clots. Shear wave attenuation is also an acoustic parameter related to tissue viscosity and it is unexplored in the case of blood clots. The use of shear wave attenuation has shown encouraging results in simulations and on phantoms. However, with current methods, the calculation of the shear wave attenuation assumes a resonance-free homogeneous medium, which is not the case for cylindrical clots in blood vessels. The ultrasound envelope can also be studied statistically, and the parameters derived from these statistics reflect the microstructure of the tissues imaged. The general aim of this thesis is to characterize blood clots as they evolve, using various parameters derived from ultrasound. This characterization is intended to enable caregivers to adapt treatment administration. Another objective is to evaluate the effect of treatment on the various ultrasound parameters, in order to attest its effectiveness. To achieve these objectives, the study is divided into three parts. The first part is an in vivo study in partnership with Grenoble University Hospital to investigate the Young's modulus and statistical ultrasound parameters over time in patients with deep vein thrombosis. The patients were on anticoagulants, and the Young's modulus showed no significant changes between measurements on days 0, 7 and 30. Statistical parameters (studied according to the homodyne K statistical distribution) showed an increase in the intensity of scatterers (probably linked to an increase in the number of fibrin strands and/or number of red blood cells) and a disorganization of scatterers. One conclusion is that statistical parameters might be used to improve the characterization of blood clots even when the Young's modulus does not vary significantly. The second part focuses on the analysis of the resonance phenomenon present when shear waves pass through the clot. The aim was to find a region of interest where the calculation of the shear wave attenuation shows the least possible variation due to this behavior. Parameters related to resonance, the Young's modulus, shear wave dispersion and shear wave attenuation were plotted in phantoms of different diameters and in in vitro blood clots during coagulation. A region of interest was found, which minimized resonances when calculating shear wave attenuation. The third study investigates the effect of in vitro treatments with rt-PA on the Young's modulus, shear wave dispersion, shear wave attenuation and statistical ultrasound parameters. Porcine blood was collected and 3 clots per sample were prepared, each undergoing a different treatment condition (no treatment, treatment at 20 minutes after the beginning of coagulation and treatment at 60 minutes after the onset of coagulation). The Young's modulus decreased significantly with treatment, the shear wave dispersion increased for clots treated at 60 minutes compared to those untreated, the shear wave attenuation increased for clots treated at 20 minutes compared to those untreated, and the backscatter intensity decreased significantly in both treatment conditions. These parameters might help confirm the effect of a treatment and detect whether or not patients are resistant to it. This thesis has led to a better understanding of the mechanical and acoustic properties of blood clots during coagulation and as a function of a treatment. These properties can be used to adapt the dose and duration of treatment to reduce side effects in the management of patients.
43

Ενδοαγγειακή απεικόνιση των αγγείων κάτωθεν του βουβωνικού συνδέσμου με Οπτική Συνεκτική Τομογραφία (Optical Coherence Tomography)

Παρασκευόπουλος, Ιωάννης 18 June 2014 (has links)
Η οπτική συνεκτική τομογραφία με τη χρήση συχνοτήτων ( FD-OCT) είναι μια ενδαγγειακή απεικονιστική μέθοδος που χρησιμοποιεί εγγύς στο υπέρυθρο φως, για να παράγει υψηλής ανάλυσης εικόνες του τοιχώματος του αυλού του αγγείου. Όπως και στην τεχνολογία υπερήχων, εκπέμπεται φωτεινή ενέργεια η οποία ανακλάται και εξασθενεί, σύμφωνα με την υφή του προσπιπτομένου ιστού. Το OCT μπορεί να απεικονίσει, με ανάλυση από 10 έως 20 μm, μικροδομές του αγγειακού τοιχώματος με εξαίσια λεπτομέρεια. Μέχρι σήμερα, η δυνατότητα εφαρμογής της μεθόδου είχε περιοριστεί σε μικρές αρτηρίες διαμέτρου έως 4mm και δεν είχε εφαρμοστεί in vivo στα αγγεία των κάτω άκρων, κάτωθεν του επιπέδου των βουβώνων. Σκοπός της παρούσας μελέτης είναι να αναφερθεί για παγκοσμίως πρώτη φορά η ασφάλεια και η σκοπιμότητα της απεικόνισης με Οπτική Συνεκτική Τομογραφία του αρτηριακού άξονα των κάτω άκρων , κάτωθεν του επιπέδου της βουβώνας ( μηροϊγνυακός άξονας και κνημιαία αγγεία), καθώς και οι σχετιζόμενες με το FD-OCT επιπλοκές. Επιπρόσθετα, να διερευνηθούν για πρώτη φορά, με τη χρήση FD-OCT, τα χαρακτηριστικά του αγγειακού τοιχώματος του ανωτέρω άξονα (τόσο πριν όσο και μετά από αγγειοπλαστική ή/και τοποθέτηση stent), η μορφολογία της αθηρωματικής πλάκας, η μορφολογία και η ποσοτικοποίηση της υπερπλασίας του νέου εσωτερικού χιτώνα (neointima) εντός του stent, η επαναστένωση εντός του stent (ISR) και η κακή εναπόθεση (malapposition) των stent struts σε μια σειρά από ασθενείς που πάσχουν από περιφερική αρτηριοπάθεια (PAD). Μελετήθηκαν, με ποσοτική ανάλυση του αυλού τους (Quantitative vascular analysis), αρτηρίες με διάμετρο έως 7 χιλιοστά. Μικτά χαρακτηριστικά από περιοχές πλούσιες σε λιπίδια, εναποθέσεις ασβεστίου και ασβεστοποιημένες πλάκες, νεκρωτικές περιοχές και ίνωση εντοπίστηκαν σε όλες τις απεικονιζόμενες αθηροσκληρωτικές βλάβες. Ωστόσο, με βάση το επικρατέστερο από τα παραπάνω απεικονιστικά χαρακτηριστικά, οι βλάβες στο πλαίσιο της έρευνας ταξινομήθηκαν ως αμιγώς ινωτικές, ως ινοασβεστοποιημένες, ως πλούσιες σε λιπίδια και τέλος ως νεκρωτικές/ασβεστοποιημένες. Συσσώρευση των μακροφάγων εντός της αθηρωματικής πλάκας σημειώθηκε σε μικρό ποσοστό των de novo αθηρωματικών αλλοιώσεων. Ποικίλοι βαθμοί υπερπλασίας του νέου έσω χιτώνα απεικονίσθηκαν σε όλες τις περιπτώσεις ISR αλλοιώσεων, με καθαρά ινωτικά χαρακτηριστικά και σημαντική νεοαγγείωση σε κάποιες από αυτές. Η νεοαγγείωση συνέπεσε με το επίπεδο της μέγιστης στένωσης του αγγειακού αυλού. Σημαντικού βαθμού διαχωρισμός με μεγάλο περιορισμό του αγγειακού αυλού, τέτοιος ώστε να απαιτηθεί να τοποθετηθεί ενδοαυλικό stent, ανιχνεύθηκε σε αρκετές περιπτώσεις της de novo αθηρωμάτωσης. Η ψηφιακή αφαιρετική αγγειογραφία παρέλειψε να προσδιορίσει μεγάλο ποσοστό των σοβαρών διαχωρισμών μετά από αγγειοπλαστική. Η νεοαθηροσκλήρυνση εντός του νέου έσω χιτώνα των κνημιαίων φαρμακευτικών stents (DES), είναι ένα συχνό εύρημα τόσο στους συμπτωματικούς όσο και στους ασυμπτωματικούς ασθενείς. Μπορούμε να υποθέσουμε ότι, κατά αναλογία με τα εμφυτευμένα DES στα στεφανιαία αγγεία, η ελαττωματική ενδοθηλιοποίηση που προκαλείται από την εκλυόμενη φαρμακευτική ουσία, μαζί με την νεοαγγείωση που αναπτύσσεται μεταξύ των stent struts, μπορούν να υποδαυλίσουν την νεοαθηροσκλήρυνση εντός του νέου έσω χιτώνα των κνημιαίων DES, η οποία μπορεί να οδηγήσει σε επαναστένωση εντός του stent (ISR) και απώλεια του εμβαδού του αυλού των περιφερικών αρτηριών. Οι παρατηρήσεις της μελέτης αυτής θέτουν σε αμφισβήτηση το παραδοσιακό τρόπο κατανόησης της περιφερειακής επαναστένωσης εντός του stent ως μιας απλής υπερπολλαπλασιαστικής απάντησης στο βαρότραυμα. Η απεικόνιση με FD-OCT είναι ένα βέλτιστο πειραματικό εργαλείο για την αξιολόγηση της εξέλιξης της αθηροσκληρωματικής νόσου και την επαναστένωση του αγγείου. Μπορεί να παρέχει υψηλής ευκρίνειας ενδοαγγειακή απεικόνιση κατά τη διάρκεια αγγειοπλαστικών επεμβάσεων στα κάτω άκρα και θα μπορούσε να αποδειχθεί κλινικά χρήσιμο για τον προσδιορισμό της εντός του stent πρόπτωσης ιστού και του strut malapposition. Παρ 'όλα αυτά, δεν πρέπει να χρησιμοποιηθεί ως εργαλείο για τη συνήθη κλινική πρακτική μέχρι να προκύψουν στοιχεία από περαιτέρω κλινικές δοκιμές για τον καθορισμό των ειδικών ενδείξεων της απεικόνισης με FD-OCT στις περιφερικές αρτηρίες. / Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. OCT can readily visualize vessel microstructure at a 10- to 20-μm resolution with exquisite detail. To date, however, applicability of the method has been limited to small diameter arteries (≤4 mm). To the best of the author’s knowledge, this study is the first worldwide that demonstrates the safety and clinical feasibility of frequency domain Optical Coherence Tomography (FD-OCT) imaging of infrainguinal vessels in vivo during infrainguinal angioplasty procedures. It is also the first study that reports the use of intravascular FD-OCT to detect and characterize in-stent neointimal tissue following infrapopliteal drug eluting stent (DES) placement in patients suffering from critical limb ischemia. Quantitative lumen analysis of arteries with diameter up to 7 mm was performed. High-resolution OCT images provided exquisite two-dimensional axial and longitudinal views of the infrainguinal arteries and allowed thorough investigation of a variety of angioplasty sequela, including and not limited to intimal tears and dissection flaps, white and red thrombus, stent mesh malapposition, and intrastent plaque prolapse. Of interest, OCT identified cases of suboptimal postangioplasty outcome that single-plane subtraction angiography did not recognize and accounted. Mixed features of lipid pool areas, calcium deposits and calcified plaques, necrotic areas, and fibrosis were identified in all of the imaged atherosclerotic lesions. However, based on the predominant baseline imaging findings, lesions under investigation were classified as purely fibrotic, fibrocalcific, mostly lipid-laden and necrotic/calcified. Intraplaque accumulation of macrophages was noted in some of de novo atheromatic lesions. Varying degrees of neointimal hyperplasia were demonstrated in all cases of in stent restenosis (ISR) lesions with purely fibrotic features and considerable neovascularization in some of them. The latter finding coincided with the level of maximum vessel stenosis in all cases. Neoatherosclerosis following infrapopliteal DES placement is a frequent finding in both symptomatic and asymptomatic patients. Our preliminary observations allow us to speculate that analogous to coronary implanted DES, defective endothelialization induced by the eluted drug, along with neovascularization developing between the stent struts, may incite neointimal neoatherosclerosis, which may result in ISR and lumen loss of the peripheral arteries. It also seems that infrapopliteal neoatherosclerosis may be a significant contributing factor for ISR rather than a minor and sporadic process, highlighting the clinical significance of the phenomenon. Our observations put in dispute the traditional way of understanding peripheral in-stent restenosis as a simple hyperproliferative response to barotraumas and may explain the paramount importance of aggressive risk factor modification strategies. Neointimal neoatherosclerosis as identified by FD-OCT may have a role in the development of below-the-knee restenosis and thus warrants further investigation by larger controlled studies. Moreover, it may prove clinically useful for the determination of intrastent tissue prolapse and strut malapposition. FD-OCT should not be utilized as a tool for routine clinical practice until evidence from further clinical trials emerge to determine the specific indications for OCT imaging of the peripheral arteries.

Page generated in 0.0296 seconds