Modélisation pharmacocinétique de la réponse tumorale à la thérapie photodynamique simultanément avec l'imagerie TEP

Boubacar, Paté January 2008 (has links)
L'objectif de ce travail consiste à étudier la réponse tumorale à la thérapie photodynamique (TPD), notamment en examinant les mécanismes d'action de 2 photosensibilisateurs utilisés pour cette TPD, à savoir l'Aluminium phtalocyanine tétrasulfonée (AlPcS[indice inférieur 4]), et le Zinc phtalocyanine disulfonée (ZnPcS[indice inférieur 2]). L'étude aborde le problème à travers la modélisation pharmacocinétique décrivant la captation tumorale du [18F]-fluorodésoxyglucose durant la thérapie phtodynamique sur les tumeurs, avec comme objectif de mettre en évidence les phénomènes métaboliques transitoires durant le traitement. La tomographie d'émission par positons, qui est un outil d'imagerie puissant et non invasif permettant d'étudier in vivo les processus biologiques et moléculaires au niveau oncologique, a été combinée à la TPD pour l'évaluation en temps réel de la réponse tumorale. Des travaux antérieurs, mis en oeuvre à travers un protocole qui comporte deux tumeurs dont l'une sera traitée tandis que l'autre a servi de contrôle, ont mis en évidence le potentiel énorme de cette combinaison. En effet, la faisabilité d'utiliser l'imagerie TEP en temps réel avec des infusions continues de FDG a été démontrée afin d'étudier la réponse métabolique tumorale durant la thérapie photodynamique chez un modèle de rongeur. La pertinence de la méthode a notamment été mise en évidence dans l'étude des changements métaboliques transitoires survenant aux niveaux tumoral et systémique pendant et tout de suite après la TPD, particulièrement pour la caractérisation des mécanismes d'action de différents PS. Une simple observation visuelle a permis de noter des différences significatives entre les profils de captation du FDG, dépendamment du PS utilisé. Ces différences offrent une façon rapide de distinguer entre un mécanisme de destruction directe ou indirecte des cellules tumorales et ce, en temps réel. Toutefois, cette approche basée sur des observations et des approximations comporte malheureusement un grand handicap. Elle ne permet pas, en toute rigueur, de prévoir les comportements tumoraux. Ce mémoire propose une approche plus formelle pour étudier les mécanismes d'action des PS à travers une modélisation pharmacocinétique de la réponse tumorale. C'est le modèle pharmacocinétique standard du FDG, modèle compartimental, qui a servi de base à notre étude. En effet, nous avons, dans une première approche, introduit la notion de perturbation pour caractériser l'effet du traitement sur le comportement normal d'une tumeur. Mais cette notion de perturbation a mis en évidence le fait que la courbe sanguine est aussi affectée. En tenant compte de cette réalité, il a fallu recourir à l'analyse factorielle pour pouvoir extraire la courbe sanguine qui servira de fonction d'entrée au modèle. Nous avons supposé que cette perturbation portait sur les constantes de transfert entre les compartiments. Cela a permis de relier l'effet du traitement aux paramètres et surtout a démontré l'inutilité probable de la durée prolongée de l'illumination. Une deuxième approche a consisté à modéliser la tumeur traitée comme un ensemble de deux populations cellulaires. Cela a permis d'abord de prendre en compte la tumeur contrôle du protocole comme une référence, mais surtout d'introduire la notion de survie cellulaire après le traitement.
12

Évaluation des performances du scanner LabPET

Bergeron, Mélanie January 2009 (has links)
Ce mémoire porte sur l'évaluation et l'amélioration des performances du premier appareil commercial de Tomographie d'Émission par Positrons (TEP) pour petits animaux basé sur des détecteurs à photodiode avalanche (PDA) et une électronique de traitement entièrement numérique. Cet appareil est la version améliorée d'un premier prototype TEP basé sur les PDA datant de 1995. Cette nouvelle version a été conçue sur une plateforme électronique numérique pour améliorer à la fois la résolution spatiale, permettant de détecter de plus petites structures chez la souris, et la sensibilité afin d'injecter une dose de radiotraceur plus faible à l'animal. Le but d'utiliser une électronique numérique était d'augmenter la flexibilité du traitement des signaux pour l'adapter selon de nouvelles applications. Afin de vérifier toutes ces caractéristiques potentielles, nous avons effectué une évaluation systématique et exhaustive des performances de ce nouveau scanner (désigné sous le sigle commercial « LabPET ») pour l'application en imagerie moléculaire. Des procédures d'ajustement automatique de plusieurs paramètres du scanner, dont la tension de polarisation des détecteurs PDA dans les conditions optimales d'opération, ont été mises au point pour faciliter l'étalonnage du grand nombre de détecteurs (1536 ou 3072 selon la version du scanner). Une technique pour normaliser les délais temporels de chaque détecteur a permis d'améliorer les performances temporelles du scanner et la qualité d'image. Cette technique a aussi servi à caractériser de façon individuelle les détecteurs au niveau de leur résolution en temps, ce qui permet de connaître leurs performances et de suivre leur possible dégradation à long terme. Par la suite, les performances de l'appareil pour l'imagerie, telles que la résolution spatiale et temporelle, la résolution en énergie, la sensibilité, le temps mort et le taux de comptage, ont été mesurées en suivant dans la mesure du possible les recommandations des normes de la National Electrical Manufacturers Association (NEMA) pour l'évaluation d'appareils d'imagerie. De plus, des balises pour l'élaboration de protocoles d'acquisition ont été établies afin d'obtenir des images optimales. Pour ce faire, une caractérisation plus exhaustive de la qualité d'image à l'aide de mires et d'images de rats et de souris a été réalisée. Deux appareils avec champ axial de 3.75 et 7.5 cm ont été caractérisés dans le cadre de ce projet de maîtrise. À la suite de toutes les améliorations apportées à l'appareil et à la lumière des résultats obtenus, la plupart des concepts utilisés pour la fabrication de l'appareil ont conduit à des images de qualité supérieure.
13

Évaluation longitudinale des changements morphologiques et métaboliques survenant chez un modèle raton de convulsions fébriles atypiques

Clerk-Lamalice, Olivier January 2010 (has links)
Les convulsions fébriles (CF) surviennent chez 2 à 5 % des jeunes enfants. La grande majorité de ces épisodes sont complètement bénins et aucune conséquence ne découle de ces convulsions. Une récente étude a par contre démontré qu'au sein d'une population pédiatrique atteinte d'épilepsie du lobe temporal (ELT), plusieurs enfants ont développé des CF avant l'apparition de ce trouble neurologique. De plus, cette étude a démontré une prévalence élevée de double pathologie chez ces enfants (sclérose de l'hippocampe et malformation corticale), suggérant un lien de causalité entre les CF, la malformation corticale et le développement de l'ELT. En se basant sur ces observations cliniques, la présente étude a pour but d'étudier les changements morphologiques et métaboliques cérébraux survenant suite aux convulsions hyperthermiques chez un modèle raton atteint de dysplasie corticale focale. Pour ce faire, une analyse du changement d'intensité de signal IRM en pondération-T[indice inférieur 2] et de multiples images TEP obtenues à l'aide de différents radiotraceurs([[indice supérieur 18]F]-FDG, [[indice supérieur 13]N]-NH[indice inférieur 3], [[indice supérieur 11]C]-acétoacétate) a été effectuée. De plus, un suivi longitudinal du développement volumétrique de l'hippocampe et des ventricules latéraux a été effectué. Les résultats de cette étude présentent une atteinte plus prononcée de l'hippocampe suite aux convulsions hyperthermiques chez le cerveau avec dysplasie corticale. En effet, 5 h après l'induction des convulsions hyperthermiques, un hyposignal IRM T[indice inférieur 2] est présent dans l'hippocampe de ce groupe comparativement au groupe contrôle atteint de dysplasie corticale seule. Les images TEP acquises pendant des convulsions hyperthermiques prolongées révèlent une inhomogénéité importante de captation du [[indice supérieur 18]F]-FDG au sein des structures cérébrales. L'hippocampe est d'ailleurs la structure avec la plus faible captation de [[indice supérieur 18]F]-FDG. À P38, une atrophie de l'hippocampe dorsal et une dilatation des ventricules latéraux sont mesurées au sein du groupe d'intérêt. Nos observations nous amènent à poser l'hypothèse que les perturbations remarquées chez le rat adulte sont causées par une vascularisation immature et inhomogène de l'hippocampe à P10 causant une atteinte hypoxique durant l'épisode de convulsion fébrile atypique. Ces résultats suggèrent donc que l'hypoxie durant un épisode de convulsions fébrile atypique mérite d'être davantage investiguée afin de développer de nouvelles avenues thérapeutiques pouvant diminuer l'impact des convulsions fébriles atypiques sur le développement cérébral.
14

Correction de l'effet de volume partiel en tomographie d'émission par positrons chez le modelé animal

Guillette, Nicolas January 2011 (has links)
La quantification de la concentration de radiotraceur en imagerie par tomographie d'émission par positrons (TEP) est capitale, que ce soit au niveau clinique, mais majoritairement dans le domaine de la recherche, notamment pour l'analyse pharmacocinétique, appliquée chez l'humain et l'animal. Parmi les corrections importantes en imagerie TEP, l'effet de volume partiel (EVP) est l'un des plus complexes à corriger. Il dépend de divers phénomènes physiques liés aux performances de l'appareil, à la reconstruction de l'image ainsi qu'aux propriétés de l'objet mesuré.La correction pour l'EVP est cruciale afin de pallier la faible résolution spatiale de l'appareil TEP. Les conséquences principales de l'EVP sont une sous-estimation de la concentration d'un radiotraceur dans les objets de petite taille ainsi qu'une difficulté à cerner correctement les contours de l'objet observé. De nombreuses méthodes appliquées directement sur les images reconstruites sont proposées dans la littérature et sont utilisées dans certains cas, mais aucun consensus sur une méthode n'a encore été établi jusqu'à présent. Ce travail porte sur la compréhension de la problématique de l'EVP par différents tests mathématiques et des simulations, ainsi que sur le développement et l'application d'une nouvelle méthode de correction appliquée à l'imagerie TEP. L'argument principal de cette technique de correction est que le défaut de la résolution spatiale est enregistré au niveau des détecteurs et la correction pour ce défaut devrait être effectuée avant la reconstruction de l'image. En outre, la technique proposée a l'avantage de tenir compte non seulement de la taille, mais également de la forme de l'objet selon les différentes projections, ce qui représente un bénéfice par rapport aux approches appliquées directement sur l'image.La correction est basée sur la déconvolution des projections mesurées par des fonctions d'étalement appropriées. Celles-ci sont obtenues expérimentalement à partir de mires de cylindres de différents diamètres. Pour tester les capacités de cette technique, l'étude s'est limitée à la correction d'objets initialement isolés par régions d'intérêt sur l'image.La technique a ensuite été testée sur des images de tumeurs isolées et du coeur chez le rat, obtenues par injection de [indice supérieur 18] F-fluorodésoxy-D-glucose (FDG). Les conséquences de la correction de l'EVP ont enfin été étudiées par l'application du modèle d'analyse pharmacocinétique compartimentale du FDG dans le coeur de rat.
15

Positron Emission Tomography (PET) for the early detection of sunitinib-induced cardiotoxicity

Marrero Cofino, Gisela January 2014 (has links)
Abstract: Sunitinib (Sutent®) is a multitargeted, small molecule receptor tyrosine kinase inhibitor used as an anti-cancer drug. It has increased the overall survival rate of metastatic renal cell carcinoma patients as well as the survival time of patients with pancreatic neuroendocrine tumors. Although the clinical use of sunitinib is a significant leap forward in the therapy of those cancers, its induction of cardiac toxicity in a substantial fraction of patients remains a critical problem. Sunitinib may cause hypertension, arrhythmias, drop of the left ventricular ejection fraction and congestive heart failure, fatal in some cases. These side effects are a frequent reason for interruption of its use. The mechanism(s) underlying sunitinib cardiotoxicity are not fully understood. Similar to other receptor tyrosine kinase inhibitors, it binds to a large number of cellular kinases, thus it can affect multiple cellular processes. In vivo, the pattern of toxicity is complex and unpredictable, with symptomatic heart failure sometimes observed early during treatment. The pattern of events preceding the onset of symptomatic cardiac dysfunction during treatment is not established. This represents a significant problem for the clinical diagnosis of cardiovascular complications before they become symptomatic. The identification and early detection of those events would be highly-beneficial for the clinical management of anti-cancer therapy with sunitinib. Positron Emission Tomography (PET) is recognized for its ability to probe metabolic and functional aspects of myocardial function. Under the working concept that heart failure can occur early during sunitinib treatment, and may be sustained by early myocardial metabolic and structural alterations, we performed a study with the objective of assessing the use of PET for the early detection of sunitinib-induced ardiotoxicity. For this, we established a model of cardiotoxicity in C57BL/6 male mice given 80mg/Kg/day of sunitinib or water, orally for 4 weeks. General and cardiac toxicity were monitored by biochemical, microscopical (H&E, immunofluorescence and electron microscopy) as well as gene expression analyses and blood pressure measurements. PET scans were performed weekly using [superscript 11]C-acetate and [superscript 18]F-FDG to evaluated the myocardial blood flow (MBF), myocardial oxidative metabolism through the quantification of oxygen consumption (MVO[subscript 2]), glucose uptake (K[subscript i]), myocardial metabolic rate of glucose (MMRG) and the left ventricular ejection fractions (LVEF). We found that sunitibib was cardiotoxic as revealed by histopathology, immunostaining and electron microscopy. Signs of inflammation and tissue remodeling were found by gene expression analyses and collagen staining. No hypertension or renal damage were detected on the study. FDG-PET revealed an early decrease of the LVEF, indicative of cardiac dysfunction, which developed into grade-2 heart failure by the end of the study. However, no signs of alterations in cardiac metabolism were uncovered by FDG- or [superscript 11]C-acetate-PET. Our results hint that the onset of sunitinib-induced contractile dysfunction may occur in the absence of hypertension or overt metabolic damage and call for further studies with longer treatments to clearly mark the onset of metabolic cardiotoxicity. // Résumé: Le sunitinib est un inhibiteur de tyrosine kinase qui est utilisée comme agent anticancéreux. Bien que l'utilisation clinique du sunitinib représente une percée significative pour le traitement de certains cancers, ce médicament s’avère cardiotoxique chez plusieurs patients, une situation qui est problématique. Le sunitinib peut provoquer une hypertension, des arythmies, une chute de la fraction d'éjection ventriculaire gauche et une insuffisance cardiaque congestive qui peut être fatale. Le mécanisme responsable de la cardiotoxicité de sunitinib n’est pas encore bien compris. Comme plusieurs autres inhibiteurs des récepteurs de la tyrosine kinase, il se lie à un grand nombre de kinases et peut affecter de nombreux processus cellulaires. In vivo, les mécanismes responsables de la toxicité sont complexes et imprévisibles et une insuffisance cardiaque est parfois observée tôt pendant le traitement. La séquence des évènements menant à l'apparition d’une dysfonction cardiaque pendant le traitement n’est pas connue. Cela pose un problème important pour le diagnostic de complications cardiovasculaires avant qu'elles ne deviennent symptomatiques. Une identification précoce de ces événements néfastes serait très bénéfique pour le suivi du traitement au sunitinib. La tomographie d'émission par positrons (TEP) est une méthode reconnue pour l’évaluation du métabolisme et de la fonctionnalité du myocarde. Selon notre hypothèse de travail, une insuffisance cardiaque peut survenir rapidement pendant le traitement au sunitinib, elle est l’expression d’altérations structurelles et métaboliques au niveau du myocarde; ces modifications se produisent tôt pendant le traitement. Nous avons effectué une étude pour évaluer la faisabilité d’utiliser l’imagerie TEP pour la détection précoce de la cardiotoxicité induite par le sunitinib. La première étape a été de développer un modèle de cardiotoxicité chez des souris. L’induction de la cardiotoxicité s’est faite par administration orale pour une période de quatre semaines, soit de sunitinib 80mg/Kg/jour ou d'eau pour les souris contrôles. Le suivi inclut la mesure de la pression sanguine, l’évaluation des altérations biochimiques, l’expression de certains gènes et un examen histologique du myocarde. Un suivi par imagerie TEP a été effectué chaque semaine avec du [indice supérieur 11]C-acétate et du [indice supérieur 18]F-FDG afin d'évaluer le flux sanguin myocardique (MBF), le métabolisme oxydatif du myocarde incluant la consommation d'oxygène (MVO2), l'absorption du glucose (K[indice inférieur i]), le taux métabolique oxydatif du glucose (MMRG) ainsi que la fraction d'éjection ventriculaire gauche (FEVG). Les résultats que nous avons obtenus par histopathologie, immunocoloration et microscopie électronique montrent que notre modèle est capable d’induire une cardiotoxicité. Nous avons également observé des évidences d'inflammation et de remodelage tissulaire à partir de l’étude de l'expression de certains gènes et de l’analyse de l’accumulation de collagène. Nous n’avons pas observé d’hypertension ni de lésions rénales. La TEP avec [indice supérieur 18]FDG a montré une diminution rapide de la FEVG, une indication d’une dysfonction cardiaque qui a été classée comme insuffisance cardiaque de grade 2 à la fin de l'étude. Cependant, aucun signe de modifications du métabolisme cardiaque n’a été mis en évidence par TEP/[indice supérieur 18]FDG- ou TEP/[indice supérieur 11]C-acétate. Nos résultats laissent penser que l'apparition de la dysfonction contractile induite par sunitinib peut se produire en l'absence d'hypertension ou de dommages métaboliques manifestes. De nouvelles études avec des traitements plus longs permettraient peut être de mieux définir le début de la cardiotoxicité métabolique.
16

Réalisation d'un nouveau prototype combiné TEP/TDM pour l'imagerie moléculaire de petits animaux

Bérard, Philippe January 2010 (has links)
Au cours des dernières années, la tomographie d'émission par positrons (TEP) s'est imposée comme l'outil diagnostique par excellence pour déceler la présence de tumeurs et caractériser leur statut métabolique. Comme les images TEP souffrent généralement d'une localisation anatomique imprécise, le diagnostic est d'autant plus fiable lorsque l'information fonctionnelle et moléculaire fournie par la TEP peut être complétée par l'information anatomique détaillée obtenue par une autre modalité d'imagerie comme la tomodensitométrie (TDM) ou l'imagerie par résonance magnétique (IRM). L'émergence de l'imagerie multi-modale TEP/TDM (ou"PET/CT") permet d'obtenir, à tour de rôle, l'information anatomique et métabolique du patient en effectuant successivement les examens TDM et TEP sans avoir à déplacer le patient d'une salle à l'autre, ce qui facilite beaucoup les procédures de recalage d'images. Toutefois, il peut arriver, vu le déplacement du lit du patient d'un scanner à l'autre, que le patient bouge volontairement ou involontairement (mouvement péristaltique, cardiaque ou pulmonaire), ce qui cause des imprécisions dans les images fusionnées. Afin d'éviter ce problème, un simulateur TEP/TDM reposant sur un système de détection commun, celui du scanner LabPET(TM), a été développé. Détectant à la fois le rayonnement émis par le radiotraceur utilisé en TEP et les rayons-X de plus faible énergie utilisée en TDM, des images TEP/TDM ont été obtenues sans aucun déplacement du sujet. Pour obtenir ces images, des algorithmes numériques de traitement de signal ont été développés afin de diminuer l'empilement de signaux et ainsi mieux discerner les photons incidents du niveau de bruit électronique. De plus, des algorithmes de reconstruction d'images adaptés à la géométrie du simulateur ont été développés. Les résultats obtenus ont démontré qu'il est possible d'obtenir, avec relativement peu de radiations ionisantes, des images anatomiques avec un contraste suffisant pour l'imagerie moléculaire. Cependant, la résolution spatiale obtenue avec cet appareil n'était pas suffisante pour bien identifier les structures anatomiques fines chez la souris (le modèle animal par excellence en recherche biomédicale). Le détecteur LabPET II, dont les pixels font 1.2 × 1 2 mm[indice supérieur 2] a donc été développé afin d'atteindre une résolution submillimétrique en imagerie TEP et de l'ordre de 500 [micro]m en imagerie TDM. Fabriqué à partir de deux matrices de photodiodes avalanches, ce détecteur comptant 64 canaux d'acquisition individuels a été caractérisé ainsi que son électronique. Le rehaussement du simulateur avec ces détecteurs permettra de construire sous peu le premier appareil TEP/TDM avec un nouveau système de détection. Les applications de ce type d'appareil en recherche sur modèle animal sont nombreuses et diversifiées : étude de la croissance normale, étude de l'évolution des maladies et évaluation de l'efficacité des thérapies, développement de produits radiopharmaceutiques, etc.... Chez l'humain, l'approche TEP/TDM combinée proposée permettra d'améliorer la détection précoce des cancers et de faciliter le suivi des patients sous thérapie grâce à une réduction importante des doses de radiations.
17

Conception et réalisation de l'électronique frontale numérique 3D pour une matrice de détecteurs monophotoniques destinée à la tomographie d'émission par positrons

Tétrault, Marc-André January 2017 (has links)
La recherche en médecine et en biologie s'appuie sur des appareils de mesure divers qui facilitent le diagnostic et le suivi du traitement. Parmi ces appareils, ceux visant l'imagerie moléculaire, par exemple la tomographie d'émission par positrons (TEP), se démarquent par leur capacité à apercevoir les signes distinctifs des maladies comme le cancer dès les premiers stades, et ce grâce à des traceurs métaboliques et/ou fonctionnels spécifiques. En plus du diagnostic, ces appareils permettent de mieux comprendre et étudier ces maladies en vue de développer de nouveaux ou meilleurs traitements. Pour appuyer les biologistes et médecins dans leur travail, les développeurs cherchent toujours à améliorer la qualité des images TEP, notamment grâce à la mesure du temps de vol (TDV) des rayons ionisant issus du positron. Le Groupe de Recherche en Appareillage Médical de Sherbrooke propose un concept de détecteur novateur destiné aux scanners TEP avec TDV, suivant la chaîne de détection connue d'un cristal scintillateur, un photodétecteur et l'électronique de lecture. L'architecture proposée exploite une matrice de photodiodes à avalanche monophotonique (PAMP) à numérisation directe plutôt que par somme en courant. Cette méthode permet de distinguer et compter individuellement chaque photon lumineux sortant du scintillateur, à condition que l'électronique frontale soit assez rapide dans les conditions d'utilisation normale. Afin de maximiser ce potentiel, toute l'électronique doit être intégrée à même le photodétecteur. Puisque l'électronique de détection et de traitement partage a priori la même surface de semi-conducteur, les concepteurs doivent choisir un équilibre entre la surface sensible et le niveau d'intelligence intégrée. Or, la densité croissante des canaux de détection TEP exige de plus en plus de traitement en temps réel pour avoir un appareil d'intérêt pour les biologistes. L'intégration verticale apparaît comme la solution naturelle pour ce problème en permettant de placer les circuits intelligents sous la matrice de photodétection. Ce projet de doctorat vise la conception de l'architecture d'acquisition et l'intégration des sous-systèmes électroniques de ce microsystème. Ces travaux ont mené au développement d'un discriminateur de bruit numérique sans dégradation de la mesure temporelle, à la fabrication et la caractérisation d'un prototype d'architecture à intégration verticale avec un circuit de conversion temps numérique (CTN) par canal, et enfin à une étude qui guidera les développements futurs pour la conception de détecteurs à plusieurs CTN. Ces contributions sont détaillées en trois articles distincts intégrés à la thèse. La recherche conclu que pour le cristal LYSO, d'avoir un ou quelques CTN précis et à faible gigue est plus importante que d'en avoir en grand nombre. Par contre, pour les matériaux à venir, ce nombre de CTN aura aussi un impact significatif sur le résultat final, changeant ainsi le paradigme initial de conception du microsystème.
18

Méthodes hilbertiennes pour la correction d'atténuation en Tomographie d'Émission Monophotonique

Nasr, Elie 11 July 2008 (has links) (PDF)
Cette thèse traite de reconstruction d'images à partir de projections parallèles atténuées. Ce problème mathématique trouve son application principale en imagerie médicale, et en particulier en tomographie d'émission monophotonique avec correction d'atténuation sous l'hypothèse que l'atténuation (supposée quelconque) est connue et quelconque sur la région d'émission. Dans un premier temps, nous décrivons les principes physiologiques et mathématiques de la tomographie d'émission monophotonique. Ensuite, nous présentons une méthode de reconstruction itérative basée sur la prise en considération du phénomène d'atténuation, principal élément perturbateur en imagerie par émission monophotonique. Cette méthode est une généralisation de l'algorithme de reconstruction algébrique classique (ART); elle introduit un terme de correction d'atténuation exact. Finalement, nous exposerons des exemples numériques et nous discuterons de la performance de notre algorithme selon le choix de plusieurs paramètres.
19

Amélioration des algorithmes de reconstruction d'image pour la tomographie d'émission par collimation à trous larges et longs

Simonnet, Richard 29 November 2010 (has links) (PDF)
Le projet CACAO - Caméra A Collimation Assistée par Ordinateur - a pour but d'améliorer la qualité des images scintigraphiques. Des collimateurs à trous plus larges et profonds sur les gamma caméras, ainsi qu'un mouvement de balayage supplémentaire dans le protocole d'acquisition permettraient d'améliorer à la fois la résolution spatiale et la sensibilité des caméras; mais cela implique l'utilisation de nouveaux algorithmes de reconstruction. Avant cette thèse, la reconstruction des images CACAO se basait sur un algorithme utilisant pour la déconvolution la transformée de Fourier rapide qui présente un avantage en terme de rapidité et a donné des résultats très intéressants. Cependant un travail basé sur la théorie de l'information nous fait penser qu'il est possible d'obtenir de meilleurs résultats. L'étape limitante du projet étant la déconvolution, le travail de thèse avait pour but d'étudier et d'améliorer cette étape avec de nouveaux algorithmes. Plusieurs algorithmes basés sur une déconvolution appelée minimale avec un traitement ligne par ligne de l'image et l'utilisation de programmation linéaire ont été développés et donnent de bons résultats dans plusieurs cas sur des données exactes. Nous avons ensuite appliqué cette idée au problème dans son ensemble, ce qui donne de bons résultats sur des données exactes et permet également de simplifier la reconstruction. Nous avons aussi effectué la dualisation de nos données qui permet de réduire le temps de calcul et de traiter de plus grandes images. Enfin, nous avons mis au point la déconvolution médiane qui se montre efficace pour des images bruitées.
20

Étalonnage automatique des détecteurs pour scanner LabPET II

Jürgensen, Nadia January 2017 (has links)
Depuis une vingtaine d'années, le GRAMS et le CIMS travaillent en collaboration dans le domaine de l'imagerie médicale, plus précisément sur la tomographie d'émission par positrons destinée à la recherche préclinique sur petits animaux. Après le scanner TEP Sherbrooke en 1994 et le LabPET I commercialisé par Advanced Molecular Imaging (AMI) Inc., Gamma Medica Ideas et GE Healthcare au cours des années 2000, l'aspiration vers de meilleures performances est le moteur de la réalisation d'une nouvelle version : le LabPET II. L'augmentation importante du nombre de détecteurs, nécessaire pour atteindre une meilleure résolution spatiale, amène de nouveaux défis autant sur le plan matériel que logiciel. Un des défis est de compenser les disparités en gain des détecteurs à base de photodiodes à avalanche (PDA) qui engendrent des différences intercanaux. Le but de ce projet de maîtrise est de développer et d'implémenter un algorithme capable de corriger ces différences de façon automatisée.