• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 21
  • 10
  • 1
  • Tagged with
  • 80
  • 80
  • 44
  • 34
  • 30
  • 21
  • 18
  • 18
  • 14
  • 13
  • 13
  • 12
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Traitement des eaux grises par réacteur à lit fluidisé et dangers liés à leur utilisation pour l'irrigation d'espaces verts urbains / Greywater treatment by a fluidized bed reactor and impacts related to their use for irrigation of urban green spaces

David, Pierre-Luc 26 November 2013 (has links)
Les eaux grises (EG) peuvent être considérées comme une ressource alternative à l’eau potable et peuvent donc être réutilisées, par exemple, pour l'arrosage d'espaces verts pour lequel une qualité ''eau destinée à la consommation humaine'' ne semble pas nécessaire. Toutefois la présence de microorganismes pathogènes et de composés organiques peut entraîner des risques sanitaires et environnementaux. Il est donc nécessaire de traiter ces EG avant de les réutiliser et caractériser les risques liés à leur recyclage, jusqu'à présent peu connus. Pour répondre à ces objectifs, la démarche a consisté à caractériser les EG afin de choisir un traitement adapté. Le procédé biologique retenu est un réacteur à lit fluidisé aérobie. Son optimisation a été basée sur l’étude de son comportement hydrodynamique et sur la cinétique de biodégradation des EG. Ses performances épuratoires ont également été déterminées. La qualité des EG traitées produites atteint les objectifs attendus par la réglementation française pour l'irrigation d'espaces verts avec des eaux usées traitées. En effet, la DCO et les MES obtenues dans l'effluent traité sont respectivement de 26 mg O2.L-1 et 5,6 mg.L-1. Le réacteur a permis de traiter 144 L.j-1 d'EG durant 16 mois. Trois parcelles de pelouse ont été irriguées respectivement par des EG brutes, des EG traitées et par de l’eau potable. Contrairement à la parcelle irriguée par les EG brutes, l'analyse de risques n'a montré aucune différence significative entre celle irriguée par les EG traitées et celle irriguée par l'eau potable. Ces travaux démontrent que les EG traitées produites dans cette étude peuvent être employées pour l’irrigation d’espaces verts. / A level of water quality intended for human consumption does not seem necessary for domestic uses such as irrigation of green spaces. Alternative water supplies like the use of greywater (GW) can thus be considered. However, GW contains pathogenic microorganisms and organic compounds which can cause environmental and health risks. As the risks related to recycling are unknown, GW treatment is necessary before reusing. To describe the risks related to GW reuses, the scientific approach performed in this study was to characterize domestic GW in order to select an appropriate treatment. The biological process chosen is an aerobic fluidized bed reactor. As this process has never been developed for GW, an optimization step based on the study of its hydrodynamic behavior and the kinetics of biodegradation of GW was performed. The treatment performances were then determined. The treated GW produced in this study reached the threshold values expected by the French regulation for irrigation of green spaces with treated wastewater. Indeed, the COD and the TSS obtained in treated GW were respectively 26 mg O2.L-1 and 5.6 mg.L-1. The fluidized bed reactor has been used to treat 144 L.d-1 of GW for 16 months. Three lawn plots were irrigated respectively with raw GW, treated GW and tap water asa reference. Contrary to the lawn plot irrigated with raw GW, the risk analysis performed in this study has shown no significant difference between the law plot irrigated with treated GW and the one irrigated with tap water. This study shows that treated GW produced from the fluidized bed reactor developed in this experiment can be used for irrigation of green spaces.
52

Evaluation d'un système de traitement à base de biomasse végétale pour le traitement décentralisé des eaux usées : du pilote à l'échelle industrielle / Evaluation of a lignocellulosic biomass-based processing system for decentralized wastewater treatment : from pilot plant to full-scale

Villalobos Garcia, Jésus 15 June 2018 (has links)
L'assainissement a de tout temps été une préoccupation majeure pour des questions d'hygiène et de santé publique. Une installation d'assainissement non collectif (ANC) assure la collecte, le transport, le traitement et l'évacuation des eaux usées domestiques. En France, l’ANC représente 20 % des installations de traitement des eaux usées domestiques. Cela concerne une population de 12 millions d'habitants, soit environ cinq millions d'installations en zones rurales. Parmi les technologies utilisées dans l’ANC, les systèmes de filtration biologique utilisant un milieu filtrant sont souvent mis en oeuvre. Le traitement des eaux usées (élimination des matières en suspension et de la matière organique) est effectué par les actions conjointes de filtration, et de biodégradation par des bactéries se développant au sein du milieu filtrant. Historiquement, des matériaux comme le sable et la tourbe sont les plus utilisés, et plus récemment des milieux à base de copeaux de coco venus remplacer la tourbe dont l’extraction est interdite, sont en développement croissant. Cependant, l’empreinte carbone produite par l'importation depuis l'étranger de matériaux tels que ce dernier est très importante. Dès lors l’utilisation de sousproduits agro-industriels locaux pourrait la diminuer et rendre l’utilisation de ces nouveaux milieux filtrants plus compatible avec des critères environnementaux. Le premier objectif de cette thèse est de déterminer le degré de fiabilité en conditions réelles d’un milieu filtrant innovant d’origine végétale ayant fait ses preuves en conditions de laboratoire. L’étude est basée sur la mise en parallèle de résultats obtenus en laboratoire et sur le terrain. Au laboratoire, une approche hydraulique a permis de caractériser le fonctionnement du lit filtrant. Sur le terrain, l’évaluation d’un filtre compact qui fonctionne de façon continue depuis plus de quatre ans et de cinq autres installations a été réalisée. Pour l’ensemble des installations, le milieu filtrant testé permet d’obtenir une qualité des eaux rejetées en accord avec la règlementation en vigueur. Les pourcentages moyens de réduction estimés de la DCO, de la DBO5 et des MES sont respectivement de plus de 79 %, 98 % et 88 %, confirmant ainsi la forte dégradation de la matière carbonée et de la pollution particulaire. Le second objectif de cette thèse consiste à établir un jeu de paramètres physicochimiques permettant de guider le choix de nouveaux matériaux potentiellement utilisables en ANC. Pour ce faire, la caractérisation des paramètres physicochimiques clés de nouveaux matériaux et des paramètres hydrauliques des lits filtrants correspondants a été effectuée. Une analyse statistique a permis d’étudier les corrélations entre ces paramètres et les performances épuratoires des matériaux. Au final, une méthodologie de sélection a été proposée. / Sanitation has always been a major concern for hygiene and public health issues. An on-site sewage facility (OSSF) ensures the collection, transportation, treatment and disposal of domestic wastewater. In France, the OSSF represents 20% of domestic wastewater treatment facilities. This represents a population of 12 million or about five million rural settlements. Among the technologies used in the OSSF, biological filtration systems using a filter media are often implemented. The treatment of wastewater (removal of suspended solids and organic matter) is carried out by the joint actions of filtration, and biodegradation by bacteria developing within the filter media. Historically, materials such as sand and peat are the most used. More recently coconut-based media to replace peat, the extraction of which is prohibited, are in increasing development. However, the carbon footprint of foreign imports of materials such as coconut is very important. Therefore, the use of local agro-industrial by-products could reduce the carbon footprint and make the use of these new filter media more compatible with environmental criteria. The first objective of this PhD thesis is to determine the degree of reliability under real conditions of an innovative filtering medium of lignocellulosic origin that has been proven successful in laboratory conditions. The study is based on the comparison of results obtained in the laboratory and in the field. In the laboratory, a hydraulic approach allowed the characterisation of the filter bed operation. In the field, the evaluation of a compact filter that has been running continuously for more than four years and five other installations has been completed. For all installations, the filter media tested allowed a quality of the discharged water in accordance with the current regulations. The estimated average reduction percentages of COD, BOD5 and TSS, are respectively over 79%, 98% and 88%, thus confirming the important degradation of the organic matter and particulate pollution. The second objective of this PhD thesis is to establish a set of physicochemical parameters to guide the choice of new materials potentially usable in OSSF. To do this, the characterisation of the key physicochemical parameters of new materials and the hydraulic parameters of the corresponding filter beds were carried out. Statistical analysis made it possible to study the correlations between these parameters and the purification performances of the materials. In the end, a selection methodology has been proposed.
53

Colonisation végétale des basins d’infiltration et de rétention : caractérisation de la flore et évolution des caractéristiques physico-chimiques de l’horizon de surface végétalisé / Vegetation of stormwater basins : flora inventory and physico-chemical characterization of vegetated surface

Saulais, Muriel 15 November 2011 (has links)
Les bassins de gestion des eaux pluviales, dont l’horizon de surface est parfois fortement contaminé, peuvent être naturellement ou volontairement colonisés par la végétation. L’objectif de ce travail est de mieux comprendre le rôle de la végétation dans le contrôle de la mobilité des métaux lourds comme le Zinc, le Cuivre et le Cadmium. Le premier volet de ces travaux, consacré à la caractérisation de la végétation se développant dans ces bassins, a montré que ces ouvrages abritaient une flore diversifiée, allant d’une végétation rudérale éparse à une végétation dense caractéristique de zones humides. Ensuite, une analyse physico-chimique multiparamétrique d’échantillons prélévés à la surface de bassins colonisés par des espèces végétales dominantes a été réalisée. Nous avons montré que les carbonates et la matière organique contrôlaient particulièrement la mobilité du Cu, Cd et Zn dans ces milieux. Les paramètres les plus variables temporellement et spatialement, sont essentiellement liés au cycle de la matière organique (nitrates, fraction métallique lié à la matière organique) mais également à l’apport de particules anthropiques (texture, métaux). Lorsque la plante est à son maximum de croissance, la mobilité potentielle des métaux est la plus élevée alors que la phase de sénescence de la plante semble conduire à un meilleur piégeage de ces contaminants. Cette thèse invite à considérer la végétation comme un agent de transformation de l’horizon de surface et à intégrer cette composante dans les futurs travaux sur la contamination des ouvrages d’assainissement urbain. / Urban stormwater basins surfaces can be highly contaminated and can be spontaneously or intentionaly vegetated. The aim of this work is to better characterize the role of the vegetation on heavy metal (Zn, Cd, Cu) mobility. Firstly, vegetation inventory has pointed out the high species diversity in these devices (from ruderal vegetation to wetland plants). Then, a physico-chemical characterization of surface samples vegetated by dominant species has been carried out. We have shown that carbonates and organic matter play a major role in the control of heavy metal mobility. The parameters which are the most spatially and temporally variable are essentially related to organic matter cycle (nitrate, heavy metal fraction bound to organic matter), and to the introduction of stormwater suspended matter (heavy metals, texture). At the maximum of plant growth phase, heavy metal mobility is enhanced and the period of plant death leads to a better heavy metal retention in the basin surface. This thesis invites us to consider plants as agents of surface stormwater basin transformation and to include plants in future research work.
54

Amélioration des connaissances sur le colmatage des systèmes d’infiltration d’eaux pluviales / Improvement of knowledge about clogging stormwater infiltration systems

Gonzalez-Merchan, Carolina 15 May 2012 (has links)
Les ouvrages d’infiltration sont utilisés aujourd’hui comme alternative au réseau d’assainissement pluvial. Ils réduisent les risques d’inondation, contribuent au piégeage de polluants permettant ainsi de limiter la détérioration des milieux aquatiques superficiels et sont reconnus pour recharger la nappe. Cependant leur fonctionnement est affecté à long terme par le colmatage réduisant leur performance hydraulique. Par ailleurs, lorsque ces systèmes sont munis de surverses, le colmatage limite les capacités d’interception des flux d’eau et des polluants. Le colmatage constitue donc un facteur clé dans le fonctionnement de ces systèmes tant sur un plan hydraulique qu’environnemental. Cette thèse a pour but de mesurer et de comprendre l’évolution spatio-temporelle du colmatage à une échelle mégascopique (l’échelle d’un ouvrage extensif type) et diachronique (sur le moyen terme). Pour cela une approche expérimentale a été menée au sein de l’Observatoire de Terrain en Hydrologie Urbaine (OTHU) selon trois niveaux d’investigation sur un même ouvrage en conditions réelles de fonctionnement. Un premier niveau (échelle globale) a consisté à mesurer l’évolution temporelle du système pris dans son ensemble grâce au calage de la résistance hydraulique au sens du modèle de Bouwer. Cette étape a nécessité de mesurer et d’exploiter des données en continu de flux d’eau, de sédiments, de matière organique apportés au système, les facteurs environnementaux comme la température d’air et d’eau, l’ensoleillement, le rythme, la nature des événements pluvieux, la saisonnalité, etc., sur un historique de 8 ans. Cette étape nous a mis en évidence la dynamique d’évolution du colmatage et le rôle bénéfique du développement de la végétation sur le maintien de la capacité d’infiltration globale d’un ouvrage de ce type. Un deuxième niveau (échelle semi globale) nous permettant de distinguer l’évolution temporelle du colmatage du fond et des parois, a montré leur dynamique respective (rapide pour le fond, très lente voire inexistante pour les parois). Un troisième niveau (échelle locale) a tenté d’explorer la répartition spatiale et temporelle du colmatage sur le fond des ouvrages sur des échelles de temps plus courtes. L’approche expérimentale a consisté à caractériser la couche colmatante en terme physico chimique et dans une moindre mesure biologique (conductivité hydraulique à saturation, granulométrie, porosité, masse volumique apparente, masse volumique des particules solides, matière organique, biomasse). Elle a analysé également le rôle de la végétation spontanée sur la capacité d’infiltration vis-à-vis des caractéristiques de l’horizon de surface et la structure aérienne et racinaire des espèces présentes. Enfin des analyses statistiques de l’évolution du colmatage à chaque échelle a mis en évidence la part potentiellement importante du colmatage biologique sur ces systèmes alors que, pour la gestion des eaux pluviales ce facteur est généralement négligé. / Infiltration systems are widely used in urban stormwater management. Infiltration systems can significantly reduce stormwater discharges to sewer systems and may therefore contribute to the mitigation of flooding problems. In addition infiltrations systems also help to reduce stormwater pollution, contribute to groundwater recharge and to water course protection. However, the hydraulic performance of infiltration systems decreases with time due to clogging effects. A clogged layer limits the transfer of water and pollutants in infiltrations systems. The clogging has a significant impact on the long-term performance of a system. The aim of this PhD study is to better understand spatio-temporal evolution of clogging on large infiltration systems involving different scales: (i) global scale, (ii) semi - global (the whole bottom and the sides), (iii) local scale (different part of the bottom). An experimental approach has been carried out in the OTHU project (Field Observatory on Urban Hydrology, www.othu.org). An infiltration basin studied with three investigations scales under real operation conditions. In a global scale, the temporal clogging evolution of the system was evaluated in terms of hydraulic resistance. This clogging indicator was calibrated from Bouwer’s model. Water inflow, TSS, COD, climatic factors (air temperature and solar energy), stormwater events and season variations were measured. The results describe the clogging evolution over 8 years. It indicates that vegetation may have a beneficial effect on infiltration capacity. In a semi global scale study, clogging evolution at the bottom and the sides, of the infiltration basin was evaluated. It proved that the clogging mainly occurs at the bottom, that is, the bottom was clogged fast and the clogging at the sides was slow. Local scale study, spatial distribution and temporal evolution of clogging at the bottom with in situ measurements during 2 years were investigated. The study characterised the clogged layer, with bio physic-chemical parameters (i.e., were investigated hydraulic conductivity, porosity, grain size, dry bulk density, organic matter and biomass content). This analyze compared also the role of different types of spontaneous vegetation. The result showed the high spatio-temporal heterogeneity on the infiltration surface. Statistical analysis of clogging evolution in each scale showed the significant impacts of biological activity in the stormwater infiltration basins, which was often neglected
55

Procédés physico-chimiques de décontamination et impact des rejets aqueux de la filière traitement de surface : approches chimique et écotoxicologique / Physicochemical processes for decontamination and impact of surface treatment wastewaters : Chemical and ecotoxicological approaches

Charles, Jérémie 10 December 2012 (has links)
Les traitements de surfaces (TS) utilisent d’importants volumes d’eau et de nombreux produits chimiques dans leurs procédés industriels. Le principal problème environnemental de la filière TS est celui de la forte charge polluante de leurs eaux usées. En effet, celles-ci sont complexes et difficiles à traiter. Ce travail de thèse a permis d’étudier plusieurs stations de décontamination de la filière TS avec comme principal objectif de démontrer l’intérêt, à la fois chimique et écotoxicologique, de leur optimisation. Pour atteindre notre objectif, les procédés de décontamination industriels ont été étudiés et optimisés. L’intérêt des traitements proposés en matière d’efficacité environnemental a également été évalué en mettant en œuvre des bio-essais basés sur l’utilisation de trois bio-indicateurs. Les résultats ont mis en évidence que les rejets du TS sont caractérisés par une polycontamination, organique et surtout métallique, fortement variable dans le temps. En outre, ces rejets ont une toxicité élevée envers les trois bio-indicateurs étudiés. Des bio-essais in vivo ont confirmé le rôle prépondérant des métaux dans la toxicité des rejets. L’optimisation des stations de décontamination a été réalisée en laboratoire, puis transposée et validée sur site industriel. Cette optimisation a permis d’améliorer significativement les abattements chimiques et il a également été démontré que l’utilisation de traitements de finition permet de tendre vers le rejet zéro. Après mise en œuvre des traitements, la toxicité des rejets a été considérablement réduite, démontrant ainsi l’existence d’une relation entre « efficacité chimique » et « réduction des impacts environnementaux ». / The surface treatment (ST) industry is currently undergoing major upheavals, particularly concerning environmental aspects, due to increasingly stringent standards. ST uses large volumes of water and chemicals in its manufacturing processes and its wastewater is acknowledged as being among the most polluting. The main environmental problem facing ST plants is the high pollution load of the effluent they generate. In this thesis, we analyzed and optimized three physicochemical units for the treatment of ST industrial wastewaters. We present the abatements obtained in the levels of pollution after the various chemical optimizations validated in the laboratory and then transposed to the industrial site. To evaluate the utility of each optimization proposal, bioassays using three bioindicators (Daphnia magna, Gammarus pulex, Lactuca sativa) were also carried out on the effluents of the treatment plants. The results showed that discharge waters were characterized by a polycontamination, organic and metallic, highly variable in time. These effluents also presented a high toxicity towards the bioindicators studied. Bioassays confirmed the preponderant role of metal in the toxicity. The optimization of the station and chemical treatment proposed reduced the organic load and the concentrations of metals. Decreasing pollutant concentrations in the wastewaters led to a significant reduction of their toxicity on the three bioindicators. This demonstrates that there is a relationship between “chemical efficiency” and “reduction of environmental impact”.
56

Optimisation d'un procédé de traitement des eaux par ozonation catalytique / Optimization of a wastewater treatment process by catalytic ozonation

Abouzlam, Manhal 10 January 2014 (has links)
Le principal objectif de la thèse est l'optimisation d'un procédé d'oxydation avancée par la mise en œuvre des outils de l'automatique moderne.Le procédé considéré concerne l'ozonation catalytique utilisé pour traiter les eaux résiduaires industrielles. L'optimisation de ce procédé consiste à contrôler l'abattement des polluants tout en minimisant le coût de fonctionnement du procédé. La mesure en ligne de la concentration en polluant est fournie par l'absorbance, grandeur corrélée à la DCO. Le procédé est alors considéré comme un système à une entrée, la puissance du générateur d'ozone, et deux sorties, l'ozone dans les évents et l'absorbance.L'identification du procédé a mené à l'estimation d'un modèle linéaire pour construire les lois de commande et d'un modèle non-linéaire, de type modèle de Wiener, pour tester les correcteurs en simulation avant les essais expérimentaux.Les trois commandes testées, la commande par modèle interne, la commande optimale et la commande H∞, permettent de rejeter des perturbations sur la concentration en polluant dans les effluents à traiter. Des analyses de stabilité du système bouclé, vis-à-vis de retards sur la commande, ont été menées.Les résultats expérimentaux obtenus ont permis de conclure sur les gains significatifs apportés par ces développements.La méthodologie développée pour cette application peut être étendue à d'autres procédés afin de faciliter le développement industriel des procédés d'oxydation avancée. / The main goal of the PhD thesis focuses on the optimization of an advanced oxidation process by implementing the modern control tools.The considered process is a lab-scale pilot of industrial wastewater treatment by catalytic ozonation. The optimization of this process is achieved by controlling the pollutant abatement while minimizing the high operating costs. The online measurement of the pollutant concentration is provided by the absorbance which is correlated with COD. Therefore, the process is considered as a system with one input, the ozone generator power, and two outputs, the ozone gas concentration at the top of the reactor and the absorbance.A linear model of the process was identified. It allowed calculating the control laws. And a nonlinear model, with a so-called Wiener model structure, was also identified to test the controllers in simulation before the experiments.The three control methods applied, the internal model control, the optimal control and the H∞ control, allow rejecting disturbance on the pollutant concentration of the effluent to be treated.The stability of closed-loop system with delayed control input was analyzed.The experimental results show the significant benefits provided by this closed-loop system.The methodology developed for this application can be extended to other processes to facilitate the industrial development of advanced oxidation processes.
57

Procédés de Fenton et photo-Fenton homogène et hétérogène : impact d’un agent complexant du fer, l’acide éthylènediamine-N,N’-disuccinique (EDDS) / Homogeneous and heterogeneous Fenton and photo-Fenton processes : impact of iron complexing agent ethylenediamine-N,N'-disuccinic acid (EDDS)

Huang, Wenyu 25 May 2012 (has links)
Dans cette étude nous avons utilisé le bisphénol A (BPA) comme polluant modèle pour analyser l’efficacité des différents processus de Fenton et photo-Fenton mis en place. Dans un premier temps nous avons étudié le processus de Fenton en présence du complexe Fe(III)-EDDS utilisé comme source de fer. Différents paramètres physico-chimiques (concentrations en H2O2, Fe(III)-EDDS, O2 et le pH) ont été testés afin d’optimiser l’efficacité du système en termes de dégradation du BPA. Parallèlement, le même type d’étude a été mené en présence de lumière (de 300 à 450 nm) afin d’étudier le processus de photo-Fenton. Dans les 2 cas nous avons mis en évidence un effet du pH peu commun puisque la dégradation de BPA est plus rapide et importante plus le pH est élevé dans une gamme allant de 3,0 à 9,0. Dans le but de comprendre le mécanisme mis en jeu des expériences d’inhibition de radicaux (·OH et HO2●/O2●-) ont été réalisées. Une des conclusions importantes de ce travail est que dans les deux systèmes le complexe Fe(III)-EDDS joue un rôle très positif pour la dégradation du BPA. De plus, nous avons également montré que ces processus étaient très efficaces pour des pH proches de la neutralité et faiblement basiques. La comparaison avec d’autres complexant du fer (EDTA, citrate, oxalate) montre qu’en présence du complexe Fe(III)-EDDS nous obtenons l’efficacité la plus importante. Ce résultat et le fait que les processus soient très efficaces à pH neutre ou faiblement basiques montrent que le complexe Fe(III)-EDDS est vraiment une source de fer très prometteuse dans les processus de Fenton et photo-Fenton. Dans une troisième partie nous avons regardé l’effet d’EDDS dans un système hétérogène en présence de Goethite comme source de fer. Dans ce chapitre il a été mis en évidence que l’EDDS inhibe le processus de Fenton, EDDS s’adsorbe fortement à la surface et limite la réactivité de H2O2 avec la surface de la Goethite. Par contre dans le processus de photo-Fenton, EDDS augmente l’efficacité de dégradation du BPA à pH proche de la neutralité et à faible concentration en H2O2. / In this study we used the bisphenol A (BPA) as a model pollutant to analyse the efficiency of the Fenton and photo-Fenton processes. In the first part of the thesis, we studied the Fenton process in the presence of the complex Fe(III)-EDDS used as iron source. Different physicochemical parameters (concentrations of H2O2, Fe(III)-EDDS, O2 and pH) were tested with the goal to optimized the efficiency of the system in terms of BPA degradation. In the same time, the same kind of experiments were performed in the presence of light (emission from 300 to 450 nm) to study the photo-Fenton process. In the two cases (Fenton and photo-Fenton), we observed a strong and not usual pH effect. Indeed, the degradation of BPA is faster and more important when the pH is higher in the range between 3.0 and 9.0. To understand the mechanisms involved in such processes, some inhibition experiments of radicals (·OH and HO2●/O2●-) were performed. One of the most important conclusion of this research work is that the Fe(III)-EDDS complex plays a very positive role for the degradation of BPA. Moreover, in the presence of Fe(III)-EDDS the Fenton and photo-Fenton processes are very efficient in neutral and slightly basic pH. The comparison with other iron complexes (EDTA,citrate, oxalate) shows that in the presence of Fe(III)-EDDS complex we obtained the better efficiency for the degradation of BPA. This result and the fact that Fe(III)-EDDS is efficient until pH 9.0 show that Fe(III)-EDDS complex is really a promising iron source for the Fenton and photo-Fenton processes. In a third part, we studied the effect of EDDS in a heterogeneous system in the presence of Goethite as an iron source. In this chapter, we demonstrated that the presence of EDDS is detrimental for the Fenton process and leads to an inhibition of the process. In fact, EDDS is strongly adsorbed at the surface of the Goethite and avoid the reactivity of H2O2 at the Goethite surface. On the contrary, in the photo-Fenton process EDDS increases the efficiency of the BPA degradation for pHs near 7.0 and at low H2O2 concentrations.
58

Identification des paramètres de bioprocédés environnementaux à partir des mesures accessibles issues de la respiration / Parameters indentification of environmental bioprocesses unsing accessibles measurements from respiration

Lemaire, Cyril 29 June 2015 (has links)
Les bioprocédés environnementaux prennent une place de plus en plus importante dans le paysage industriel mondial. La complexité et la diversité des processus impliqués dans les réactions biologiques de dégradation des polluants limitent considérablement la compréhension et l’utilisation de ces procédés. De plus, les mesures disponibles pour le suivi de cette activité sont souvent hors-ligne et/ou indirectes. Dans ce cadre, les outils de modélisation phénoménologique permettent, via le choix d’hypothèses judicieuses, de lier les observations du système aux processus biologiques sous-jacents. Ces méthodes nécessitent néanmoins l’application d’une étude rigoureuse d’identifiabilité afin de pouvoir exploiter correctement les résultats obtenus. Les modèles ainsi développés permettent de capitaliser des connaissances sur la description des processus biologiques grâce aux mesures effectuées sur le système. Cette approche a été développé au travers de deux cas d’étude, correspondant à deux domaines d’application industrielle. La bioremédiation des sols contaminés aux hydrocarbures constitue la méthode la plus écologique de traitement des sols. Néanmoins, le processus de biodégradation peut être long, voire inexistant en fonction des conditions environnementales. Afin de mesurer l’efficacité de la dégradation, la mesure de la respiration en phase gaz apparaît comme étant l’observation la plus facile à mettre en œuvre. Le problème est que la simple mesure de la consommation d’oxygène est généralement insuffisante. Pour répondre à cette limite, un modèle capable d’expliquer les évolutions du quotient respiratoire apparent grâce aux différentes étapes de la biodégradation a été développé. Cette mesure pourrait alors donner une indication sur l’efficacité de la biodégradation. La seconde partie de ce travail, plus conséquente, s’intéresse à l’épuration des eaux usées par boues activées, elle reprend et amplifie l’approche méthodologique développée pour la biomédiation des sols. L’efficacité de ce traitement des eaux est grandement liée à la production de boues en excès, exprimée par le rendement hétérotrophe. Ce paramètre difficile à maitriser constitue une information primordiale pour la modélisation et la conduite des stations d’épurations. Il apparaît néanmoins que sa définition usuelle ne suffit pas à expliquer ses variations observées. Dans ce cadre, différents modèles phénoménologiques issus des travaux du groupe de travail ASM (Activated Sludge Modeling) ont été étudiés afin de décrire les variations de ce rendement apparent en introduisant les hypothèses réactionnelles liées au stockage du substrat. Une étude expérimentale en laboratoire a permis de confronter ces hypothèses à des mesures de dégradation de substrats purs par des boues activées en respiromètre. L’équilibre entre le stockage du substrat et la croissance bactérienne a ainsi été proposé comme source d’influence majeure sur la valeur du rendement. Ce travail a abouti à une clarification nécessaire de la définition du rendement hétérotrophe. / Environmental bioprocesses are gaining importance in the industrial landscape. Nevertheless, the complexity of mechanisms involved in biological reactions stays an issue for their implementation. Moreover, available measurements of biological activity are often off-tine and/or indirect. ln this context, phenomenological modeling tools are a solution to link observations of the system to underlying biological reactions, considering the right hypotheses. These methods require a rigorous sensitivity analysis in order to properly process the results. Thus, the models permit to obtain precise knowledge about biological systems thanks to indirect measurement. This approach was developed throughout two cases of study corresponding to two industrial fields of application. Bioremediation is the most ecological method for hydrocarbons contaminated soils remediation. Nevertheless, biodegradation can be long or absent depending on environmental conditions. In order to measure its efficiency, respiration measurement in the gas phase seems to be the easiest observation to implement. Oxygen measurement can be insufficient on its own, that is why a model able to describe the evolution of the apparent respiratory quotient has been developed considering the different steps of biodegradation. This observation alone could give insights on the efficiency of biodegradation. The second part of this work deals with activated sludge wastewater treatment using the theoretical approach developed for soil bioremediation. The eftïciency ofthe process depends on the excess production of sludge, which is linked to the heterotrophic yield of the reaction. This parameter is a key component for modeling and optimization of wastewater treatment plant. Most of the time, its common definition is not sufficient to explain its observed variations. In this context, several phenomenological models derived from the activated sludge models were studied to explain these variations, taking into account the substrate storage process. An experimental study was conducted in order to confront the reactional hypothesis of the models to actual measurements of single substrate degradations in respirometer. The balance between substrate storage and direct growth was proposed as a main component of the yield value. This study resulted in a necessary clarification of the heterotrophic yield definition.
59

Simulation de l’écoulement par des approches de Mécanique des Fluides Numérique et évaluation de la dispersion de principes actifs utilisés pour traiter les plans d’eau eutrophisés / Applications of Computational Fluid Dynamics (CFD) for water flow simulation and evaluation of the dispersion of an active substance used for the treatment of eutrophicated water bodies

Moussoh, Amahoué François 23 May 2016 (has links)
Ce travail se situe dans le cadre d’un projet global visant à développer un procédé innovant pour un traitement ciblé de plantes aquatiques invasives dans une masse d’eau lentique. L’un des enjeux est d’optimiser la concentration de substance active nécessaire pour éliminer les plantes ciblées sans créer de potentiels dommages écologiques. Une méthodologie basée sur une approche de modélisation ascendante a été appliquée en utilisant la Mécanique des Fluides Numérique (MFN) afin de pouvoir définir des conditions optimales pour un traitement efficace. Cette approche de modélisation a été appliquée pour la simulation de l’écoulement et la dispersion des substances actives de l’échelle d’un pilote de 1m3 à celle de plans d’eau alimentés en surface et par le fond. Cinq modèles de turbulence ont été présélectionnés afin d’évaluer leur influence sur les résultats de simulation. Le modèle RNG k-ε a été choisi définitivement après sa validation par des traçages expérimentaux à l’échelle du pilote mimant le fonctionnement hydrodynamique d’un plan d’eau réel. Des mesures expérimentales sur pilote et des simulations numériques réalisées à l’échelle de celui-ci et sur quatre configurations de plans d’eau ont permis d’évaluer l’impact de plusieurs paramètres hydrodynamiques (débit, nombre d’entrées et sorties, type d’alimentation en eau, …) et des forçages extérieurs (vent, température) sur le maintien de la concentration algicide au cours du traitement. Le vent joue principalement le rôle d'un diffuseur naturel provoquant 95% de la dilution de la concentration algicide. La prise en compte de la vitesse de réaction chimique de la substance active dans l’eau indique également une diminution de la concentration locale de substance active. Le traitement optimal ne serait donc pas seulement lié à la maîtrise de la concentration à injecter mais à une bonne compréhension de l’écoulement local / This work is part of an overall project to develop an innovative process for targeted treatment of invasive aquatic plants in a lentic water body. One of the challenges is to optimize the concentration of active substance required to remove the target plants without creating potential ecological damage. A methodology based on a bottom-up modeling approach was applied using Computational Fluid Dynamics (CFD) in order to define optimal conditions for effective treatment. This modeling approach was used for the flow and the dispersion of active substance simulations from a 1 m3 pilot to lentic water bodies fed by surface water or groundwater. Five turbulence models were preselected in order to assess their influence on the simulation results. The RNG k-ε model was selected after final validation by tracer experiments at pilot scale mimicking the hydrodynamics of a real lentic water bodies. Experimental measurements on pilot and numerical simulations carried out on scale thereof with four configurations of lentic water bodies have allowed to evaluate the impact of several hydrodynamic parameters (water flow, number of inlets and outlets, type of water supply, …) and external forcing (wind, temperature) on maintaining of algaecide concentration during the treatment. The wind mainly acts as a natural diffuser causing 95% of diluting the algaecide concentration. Taking account of the rate of chemical reaction of the active substance in water also indicates a decrease of the local concentration of active substance. The optimal treatment is not only based to the control of injected concentration but it is also related to a good understanding of the local water flow
60

Study of the influence of electrode material in the application of electrochemical advanced oxidation processes to removal of pharmaceutic pollutants from water / Étude de l'influence du matériel d'électrode dans l'application des procédés électrochimiques d'oxydation avancée au traitement des polluants pharmaceutiques

Sopaj, Flamur 06 December 2013 (has links)
La production ainsi que l'utilisation massive des produits chimiques pour divers usages, a résulté à leur introduction et accumulation dans l'environnement. Ces produits peuvent se transporter par différentes façons de leur source à des régions très lointaines de la planète, ce qui dépend de leur propriété physico-chimiques. Une quantité et variété importante de composés organiques sont utilisées dans l'agriculture comme pesticides, afin de protéger les cultures et augmenter les rendements. Les résidus de ces produits peuvent toujours se trouver dans les champs, puis sous l'effet des précipitations ils passent par lixiviation dans les fleuves et d'autres system aqueux. Les produits pharmaceutiques et les produits de soins personnels sont introduits dans l'environnement de façon continue par les eaux usés municipales. Ces substances manifestent, dans la plus part des cas, des effets perturbants sur les organismes vivants. Malgré leur concentration faible dans les eaux naturelles, le contact permanent des organismes aquatiques peut avoir des conséquences négatives telles que la modification du comportement sexuel observé chez les poissons d'eau douce. Dans le but de réduire ou éliminer la pollution chimique des eaux des nombreuses méthodes ont vu le jour, telles que: l'adsorption des polluants sur des adsorbants, la filtration membranaire, le traitement microbiologique, l'oxydation chimique et les procédés d'oxydation avancée. La plus part des méthodes utilisées dans les stations d'épuration des eaux ne détruisent pas efficacement les contaminants organiques. L'utilisation des méthodes physiques permet de les séparer de l'eau, ce qui nécessite des opérations supplémentaires pour leur élimination. Au contraire, les procédés d'oxydation avancée et en particulier les procédés électrochimiques d'oxydation avancée (méthodes développées récemment) se montrent plus efficace dans l'élimination des polluants toxiques et non-biodégradables, car ces procédés sont capables à conduire jusqu'à minéralisation totale de la matière organique. Le sujet de cette thèse repose donc sur l'application du procédé électro-Fenton qui est un procédé électrochimique d'oxydation avancée pour la destruction des contaminants organiques dans l'eau. Cette méthode fait appel aux radicaux hydroxyles (espèces très oxydantes et extrêmement réactives) pour l'élimination des polluants récalcitrants, qui sont produit in situ à travers le réactif du Fenton (H2O2 + Fe2+). Ce réactif est généré in situ électrochimiquement. . Dans ce procédé la nature du matériau de l'électrode a une importance cruciale. Ainsi nous avons étudié dans ce travail l'influence du matériel de l'anode et de la cathode sur l'efficacité du procédé électro-Fenton. Dans un premier temps nous avons étudié de manière systématique le pouvoir d'oxydation d'anode comme de différentes matériaux d'anodes tels que : BDD, Pt, DSA, PbO2, Feutre de carbone, Graphite et Fibre de carbone dans l'oxydation de l'antibiotique amoxicilline (AMX). Dans tous les cas une électrode d'acier inox a été utilisée comme cathode. La dégradation de AMX a été suivie par l'analyse CLHP alors que la minéralisation de ses solutions par l'analyseur du carbone organique totale (COT). Il s'est avéré que l'anode BDD a était l'anode la plus puissante pour l'oxydation de l'AMX tandis que l'anode DSA a présenté les performances les plus faibles. D'autre part, le feutre de carbone a présenté un comportement caractéristique; il était très efficace sur l'oxydation de l'AMX mais ces performances en minéralisation étaient médiocres. Dans l'étape suivante, quatre anodes (Pt, BDD, DSA and Feutre de carbone) ont été testées pour élucider leur influence sur l'efficacité du procédé électro-Fenton, en utilisant toujours une cathode de feutre de carbone. L'antibiotique sulfamethazine (SMT) a été choisi comme polluant modèle (...) / Permanent production and use of organic chemicals for many purposes has resulted in their introduction and accumulation in the environment. Depending on their physicochemical properties they can be transported by different ways from the source to very remote regions of the planet. Many organic chemicals are used in agriculture as pesticides for cultures protection or nutrient. Residues of these chemicals can always be found in fields, and under the effect of precipitations they leach and pass in streams and rivers. Pharmaceuticals and personal health care products and other house holding chemicals are continuously introduced in the environment through municipal wastewaters. These substances exhibit, in most of the cases, perturbation effects towards the living organisms, moreover the effect of many of them is not known yet. Despite their concentration in water is low, the exposure of organisms for long periods can lead to negative consequences, but these effects cannot be measured instantly. In order to reduce or avoid the pollution of water with chemicals many water treatment methods has been developed like adsorption of pollutants on adsorbents, membrane filtration, microbiological treatment, chemical oxidation with oxidizing agents and advanced oxidation processes. Most of the methods used in waste water treatment plants (WWTP) do not completely destroy the organic contaminants or they only separate the contaminants from water. Then they have to be deposed somewhere else remaining always a potential source of contamination. Advanced oxidation processes and in particular electrochemical advanced oxidation processes are methods developed later and are proven as more effective as they can completely oxidize the organic matter in water. The subject of this thesis is the use of electro-Fenton, an electrochemical advanced oxidation process for efficient destruction of organic pollutants in aqueous medium. In this method, organic pollutants are eliminated by H hydroxyl radicals (high oxidation power species) which are produced in situ through the Fenton's reagent (H2O2 + Fe2+) itself generated in the solution electrochemically and continuously. In this process, the electrode material is of fundamental importance in order to have an efficient process, so we have studied at large extent the influence of both cathode and anode material in this work. Firstly a systematic study on the oxidation capacity of the process of amoxicillin (AMX) as model pollutant with several anodes materials: BDD, Pt, DSA, PbO2 Carbon felt, Graphite and Carbon fibre was realised. In all cases a stainless steel electrode was used as cathode. The degradation of AMX was followed by HPLC analysis whereas the mineralization efficiency ot the process was measured by total organic carbon analyser (TOC). This revealed that BDD was the most efficient anode for AMX oxidation and DSA was the weakest one. Carbon felt showed a characteristic behaviour; it was very efficient on AMX oxidation but it could not transform AMX to CO2 and H2O. Afterwards four anodes were tested for their influence on electro-Fenton process efficiency namely Pt, BDD, DSA and Carbon felt, the cathode was always carbon felt. Sulfamethazine (SMT) was used as model pollutant. Apparent rate constants have given only moderate values of mineralization for currents lower than 100 mA. Here again the BDD anode was distinguished for its excellent mineralization capacity owing to the additional hydroxyl radicals and other oxidizing species introduced in the system. When electro-Fenton applied good degradation and mineralization results were obtained even with the DSA anode (...)

Page generated in 0.1113 seconds