• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 9
  • 9
  • 2
  • Tagged with
  • 43
  • 20
  • 18
  • 17
  • 16
  • 15
  • 12
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Qualidade de vida em gestantes no terceiro trimestre com pirose e/ou regurgitação : contribuição da cafeína, acido ascórbico e ácidos graxos

Dall'Alba, Valesca January 2003 (has links)
Introdução: Pirose e regurgitação são manifestações da Doença do Refluxo Gastresofágico (DRGE) que ocorrem freqüentemente no terceiro trimestre da gravidez, porém seu impacto na qualidade de vida de gestantes é pouco conhecido. Objetivos: 1. Mensurar a qualidade de vida em gestantes no terceiro trimestre da gravidez com Pirose e Regurgitação; 2. Avaliar a relação entre Pirose e Regurgitação e a dieta. Pacientes e Métodos: Gestantes no terceiro trimestre acompanhadas ambulatorialmente foram entrevistadas para colher dados referentes à história obstétrica, freqüência, intensidade e passado de P e R, qualidade de vida (mensurada a partir do questionário genérico SF-36), ingestão alimentar (avaliada por recordatório de 24h) e medidas antropométricas; Resultados: Foram estudadas consecutivamente 82 gestantes: 62 com pirose e/ou regurgitação e 20 assintomáticas. Pirose foi relatada por 62 (76%) gestantes e regurgitação por 58 (71%). A idade gestacional média foi 33,8±3,7 semanas, 35 (43%) apresentavam história familiar positiva de pirose e/ou regurgitação e 57 (70%) não apresentavam tais sintomas fora da gravidez. Houve redução estatisticamente significativa na qualidade de vida das gestantes sintomáticas nos seguintes domínios: Para pirose, em Limitação Física e Aspectos Sociais; para regurgitação, em Limitação Física, Aspectos Sociais, Aspectos Emocionais e Dor. Houve concordância entre presença de pirose em gestações passadas e a atual. Gestantes com pirose apresentaram-se significativamente com maior peso corporal. Ácidos graxos poli e monoinsaturados, cafeína, ácido ascórbico e sulfato ferroso foram significativamente associados com pirose e/ou regurgitação. Conclusões: 1.Pirose e / ou regurgitação diminuíram a qualidade de vida em gestantes no terceiro trimestre; 2. ácidos graxos, cafeína, ácido ascórbico e sulfato ferroso estiveram associados com pirose e/ou regurgitação. / Goals: (1) To measure health-related quality of life of third-trimester pregnant women with heartburn and/or regurgitation; (2) to investigate the association between these symptoms and diet. Background: Heartburn and regurgitation are frequent in the third trimester of pregnancy, but their impact on health-related quality of life has not been thoroughly investigated. Methods: The following data were collected for 82 third-trimester pregnant women: obstetric history, heartburn and regurgitation frequency and intensity, history of heartburn and regurgitation, health-related quality of life (SF-36 questionnaire), diet (24-hour recall), and anthropometrical measurements. Results: Sixty-two women (76%) had heartburn, and 58 (71%), regurgitation; 20 were asymptomatic. Mean gestational age was 33.8±3.7 weeks; 35 (43%) women had a family history of heartburn and/or regurgitation, and 57 (70%) did not have these symptoms before pregnancy. A significant reduction in quality of life was observed in terms of physical problems and social functioning for women with heartburn; physical problems, social functioning, emotional problems, and pain for women with regurgitation. There was agreement between reports of heartburn for present and previous pregnancies. Weight was significantly greater in pregnant women with heartburn. Polyunsaturated and monounsaturated fatty acids, caffeine, ascorbic acid and ferrous sulphate were significantly associated with heartburn and regurgitation. Conclusions: Heartburn and/or regurgitation affected health-related quality of life of third trimester pregnant women; (2) fatty acids, caffeine, ascorbic acid and ferrous sulphate were significantly associated with heartburn and regurgitation.
32

Avaliação da resposta fetal à estimulação auditiva a partir da 13° semana de gestação: estimativa temporal da viabilidade neurológica fetal

Luz, Sérgio Hecker January 2005 (has links)
Resumo não disponível
33

Estudo das Regiões Controladoras de Imprinting 1 e 2 em Oócitos, Embriões e Placentas de Primeiro Trimestre / Imprinting Control Regions 1 and 2 in Oocytes, Embryos and Early Placenta

Cristiana Libardi Miranda Furtado 10 April 2012 (has links)
O imprinting genômico é um processo epigenético essencial para o desenvolvimento normal de mamíferos com placenta e refere-se à expressão gênica alelo-específica, de acordo com a origem parental. A expressão dos genes marcados por imprinting é controlada por regiões diferencialmente metiladas (DMRs), situadas em regiões controladoras de imprinting (ICRs). O cromossomo 29 de Bos taurus possui dois domínios cromossômicos semelhantes à região 11p15.5 de humanos, que são denominados KvDMR1 (na ICR2) e H19DMR (na ICR1). Essas ICRs controlam um cluster de genes importantes para o crescimento e desenvolvimento, sendo a KvDMR1 metilada no alelo materno e a e H19DMR metilada no alelo paterno. No presente trabalho, foi verificado o padrão de metilação da KvDMR1 e da H19DMR em oócitos não maturados (Vg) e maturados in vitro (MII) e nos blastocistos inicial (Bi) e expandido (Bx) bovinos e em placentas bovinas e humanas de primeiro trimestre. Foram coletados oócitos e embriões pré-implantação no estágio de blastocisto produzidos pela técnica de Fertilização in vitro. Também foram coletados o tecido placentário e de um feto bovino de 49 dias e de uma placenta humana, com idade gestacional de 12 semanas. O DNA genômico foi extraído e modificado com bissulfito de sódio. O padrão de metilação das regiões KvDMR1 e H19DMR foi verificado por meio de clonagem e seqüenciamento do DNA modificado com bissulfito de sódio. Para as análises de expressão gênica nos oócitos e blastocistos, foi realizada a extração do RNA e em seguida o cDNA foi produzido para a quantificação relativa da expressão gênica por meio da técnica de PCR em tempo real. Os resultados de metilação para a amostra controle de espermatozóide apresentaram um perfil hipometilado para a KvDMR1 e hipermetilado para a H19DMR. Os oócitos Vg e MII mostraram um perfil hipermetilado para a KvDMR1 e nos Bi e Bx foi observado um perfil hipermetilado e hipometilado, respectivamente. Para a H19DMR, foi observado um perfil hipermetilado para as amostras Vg e MII, sendo que para os Bi foi observado um perfil hipometilado e, para os Bx, um perfil monoalélico de expressão. A expressão dos genes LIT1 e IGF2 foi relativamente baixa nas amostras analisadas, sendo que o gene LIT1 foi expresso nos mesmos níveis para todas as amostras e o IGF2 não foi expresso nos Bi e Bx. Os oócitos MII apresentaram altos níveis de expressão do IGF2 quando comparados com os oócitos Vg. Nas placentas precoces de bovinos, a porcentagem de metilação para a KvDMR1 variou entre os cotilédones de 39,6%. e 88,9%. A porcentagem de metilação para a H19DMR nos cotilédones variou entre 35,0% e 57,0% , sendo que apenas uma amostra apresentava-se completamente demetilada para esta ICR. Nas análises das vilosidades humanas, foi observado um perfil hipermetilado em todas as amostras analisadas, em que as porcentagens de metilação para a KvDMR1 e H19DMR variaram entre 84,4% e 97,9%. Os resultados mostram um perfil alterado de metilação nos oóctios MII para as duas regiões analisadas, e uma alteração nas amostras de oócitos Vg para a H19DMR. Para os blastocistos, o esperado seria um perfil monoalélico para as duas regiões, no entanto, esse resultado só foi encontrado para os Bx na H19DMR. Em bovinos, as DMRs apresentaram um funcionamento antagônico, enquanto a KvDMR1 tende a uma hipermetilação a H19DMR tende a uma hipometilação. O resultado das análises comparativas das placentas bovina e humana não sugerem uma relação do padrão de metilação dessas regiões entre essas duas espécies, no entanto, servem de base para o conhecimento do imprinting na placenta. Os estudos nos oócitos e blastocistos realizados representam um passo inicial na investigação da influencia das tecnologias de reprodução assistida no desenvolvimento embrionário, sendo o primeiro relato do funcionamento dessas DMRs nas amostras de oócitos e embriões pré-implantação bovinos. / Genomic imprinting is an epigenetic process that plays an essential role in the development of placental mammals with a parent-of-origin-specific manner of gene expression, in which only one allele is expressed. The imprinted gene expression is controlled by differentially methylated regions (DMRs), located in imprinting control regions (ICRs). In Bos Taurus, chromosome 29 presents two imprinted domains similar to human 11p15.5 region which are named KDMR1 (in the ICR2) and H19DMR (in the ICR1). Several genes that play an essential role in growth and development are under the control of the ICRs, in which the KvDMR1 is methylated on the maternal allele and the H19DMR is methylated on the paternal allele. In this study, the DNA methylation status of the KvDMR1 and H19DMR was verified in bovine non-matured germinative vesicle (GV) in vitro matured (MII) oocytes, as well in early (EA) and expanded (EX) blastocysts, and in bovine and human early placenta. The oocytes and blastocysts were collected after in vitro fertilization (IVF) techniques. Tissues from bovine placenta and fetus with 49 days of gestational age and human placenta with 12 weeks of gestational age were also collected. The DNA was extracted and modified by sodium bisulfite. The methylation pattern of KvDMR1 e H19DMR was verified by cloning and bisulfite sequencing. RNA extraction and cDNA synthesis for the relative quantification of gene expression by real time PCR were performed for oocytes and blastocysts. The methylation profile for the control sample of sperm was hypomethylated for KvDMR1 and hypermethylated for H19DMR. The GV and MII oocytes showed a hypermethylated pattern for KvDMR1 and in the EA and EX was hypermethylated and hypomethylated, respectively. The H19DMR displayed a hypermethylated pattern for GV and MII oocytes. For EA was observed a hypomethylated profile and EX presented a monoallelic expression. The LIT1 and IGF2 gene expression were low for all samples, however the LIT1 had the same level of expression in all samples while the IGF2 was not expressed in EA and EX. The MII oocytes showed high levels of IGF2 gene expression when compared with GV oocytes. The methylation levels for KvDMR1 in bovine early placenta varied between the cotyledons (39,6% and 88,9%). The percentage of methylation for H19DMR in cotyledons varied between 57.0% to 35.0%. Only one sample was not methylated for this ICR1. In human villous, a hypermethylated profile was observed for all samples, and the percentage of methylation for KvDMR1 and H19DMR varied between 84.4% e 97.9%. The results show an altered methylation profile in MII oocytes for two analysed regions and an alteration of H19DMR in GV oocytes. The expected for blastocysts was a monoallelic profile for KvDMR1 and H19DMR, however these results were observed only in EX for H19DMR. In bovine, the methylation levels of KvDMR1 and H19DMR seems to work antagonistically. While the KvDMR1 tended to hypermethylation, the ICR1 tended to a hypomethylation. The comparative analysis of bovine and human early placentas does not suggest a relationship between the methylation patterns of these regions in these two species. However, these studies provide the basis for the understanding of imprinting in the placenta. The study in oocytes and blastocysts represent an initial investigation in understanding how the assisted reproductive technologies affect the embryo growth and development, and this is the first report on the methylation patterns of KvDMR1 and H19DMR in bovine oocytes and blastocysts.
34

Ecocardiografia fetal no primeiro trimestre da gestação / First trimester fetal echocardiography

Sandra Regina Marques Carvalho 15 December 2006 (has links)
Os objetivos deste estudo foram determinar o índice sucesso na realização de um ecocardiograma fetal completo entre a 11ª e a 14ª semanas, estabelecer a semana mais adequada para a realização de um exame completo, mensurar os diâmetros dos anéis das valvas cardíacas e comparar os diâmetros obtidos com o comprimento crânio-nádegas (CCN) correlacionando a evolução das dimensões cardíacas com o crescimento fetal nesta fase evolutiva. Avaliamos por ecocardiografia 46 fetos que apresentavam translucência nucal e avaliação Doppler do fluxo do ducto venoso normais. O estudo ecocardiográfico fetal foi realizado por via transvaginal, entre a 11ª e a 14ª semanas, com intervalos seriados de uma semana. Em cada exame, foram obtidos os três principais planos ecocardiográficos básicos e os diâmetros das valvas aórtica, pulmonar, mitral e tricúspide. As medidas dos diâmetros valvares foram comparadas ao diâmetro do CCN. Os resultados demonstraram uma taxa de sucesso na obtenção de um ecocardiograma completo de 37% na 11ª semana, de 85% na 12ª semana e de 100% entre a 13ª e a 14ª semanas. O corte mais freqüentemente obtido, nas duas primeiras semanas, foi o eixo longo e o mais difícil de ser visibilizado foi o eixo curto. As curvas de crescimento dos diâmetros das valvas mitral, tricúspide, aórtica e pulmonar demonstraram uma correlação linear com o crescimento fetal com valores de r² de 0,74, 0,75, 0,77 e 0,73. Não houve diferença estatisticamente significativa entre os diâmetros das valvas atrioventriculares e entre os diâmetros das valvas ventriculoarteriais. A obtenção dos três planos ecocardiográficos básicos em 85% dos casos na 12ª semana e 100% dos casos, a partir da 13ª semana, demonstra que é possível a realização de um ecocardiograma fetal completo no primeiro trimeste da gestação, por via transvaginal. Houve correlação positiva entre os diâmetros valvares e o CCN demonstrando uma curva de crescimento neste período. A comparação entre diâmetros valvares mitral e tricúspide, do mesmo modo que, a comparação entre os diâmetros valvares aórtico e pulmonar não apresentaram diferenças estatisticamente significativas, sugerindo não haver dominância no tamanho destas estruturas, nesta fase do desenvolvimento em fetos normais. / The aim of this study was to assess the feasibility of performing a complete echocardiography study during the first trimester of pregnancy by transvaginal approach and to establish the best week to accomplish a complete evaluation. A correlation between the measurements of the diameters of the cardiac valves and the gestational age along this period of the fetal life was made. Forty-six fetuses with normal nuchal translucency and Doppler evaluation of the venous duct were submitted to fetal echocardiography studies by transvaginal approach between the 11 and 14 weeks of gestation with a week interval. The following measurements were obtained: mitral, tricuspid, aortic and pulmonary valves diameters and the crown-rump length (CRL). The obtained results of the cardiac dimensions were compared with the CRL in the four weeks determinations. The rates of complete echocardiography evaluation were 37%, 85% and 100% at 11, 12 and 13 – 14 weeks, respectively. The longitudinal view was the easiest to obtain (100% at 12 weeks) and the short view was the most difficult one. There was no statistically significant difference between neither the diameters of the mitral and tricuspid nor the aortic and pulmonary valves. The diameters of the valves were correlated with the CRL and a linear growing curve was obtained with values of r2 of 0.74, 0.75, 0.77 and 0.73 respectively. The study demonstrated the feasibility of a complete fetal echocardiography evaluation by transvaginal approach during the first trimester of gestation. The rate of a complete evaluation increased along the period and reached 100% at 13 weeks. The longitudinal view was the easiest to obtain with a success rate of 100% at 12 week. There was a linear correlation between de cardiac valves diameters and the cranial caudal measurement revealing a relationship between the cardiac and fetal development during this phase of fetal life. The absence of statistically significant difference between the left and right valves dimensions possibly means that there is no predominance of right or left chambers during this period of evaluation.
35

Acompanhamento pré e pós-natal dos casos com translucência nucal fetal aumentada / Prenatal and postnatal Follow-up of cases with increased fetal nuchal translucency thickness

Saldanha, Fatima Aparecida Targino 15 December 2004 (has links)
Objetivo: analisar o resultado das gestações e pós-natal dos fetos com translucência nucal (TN) aumentada. Método: Duzentos e setenta e cinco fetos com TN aumentada foram avaliados no setor de Medicina Fetal da Clínica Obstétrica do HC-FMUSP, com análise do cariótipo, ultra-sonografia seriada, ecocardiografias fetal e pós-natal e avaliação clinica genética pós-natal. Resultados: 14,2% apresentaram cariótipos alterados e 85,8% normais. A ultra-sonografia morfológica esteve alterada em 73,1% dos casos com cariótipo anormal e em 24,7% dos normais, destes, um terço apresentou malformações estruturais maiores, sendo 35,7% cardíacas. Resultados gestacionais adversos, como abortamento, óbitos intra-útero e neonatal ocorreram em 76,5% dos fetos com anomalias cromossômicas e em 10,2% com cariótipos normais. A avaliação pós-natal foi realizada em 72,7% das crianças, mostrando-se alterada em 14,8% dos casos. A freqüência de criança viva e saudável diminuiu com a medida da TN, que variou de 37,5%, nos casos com cariótipos normais, a 18,8% com cariótipos desconhecidos, quando a TN foi igual ou maior que 4,5 mm. Conclusão: Quanto maior a TN maior o risco de anomalias cromossômicas e, nos casos com cariótipos normais, maior a freqüência de malformações estruturais, em especial defeitos cardíacos, resultados gestacionais adversos e alterações à avaliação pós-natal / The aim of this study was to evaluate pregnancy and postnatal outcomes in fetuses with increased nuchal translucency thickness (NT). Two hundred seventy five fetuses with increased NT were examined with karyotyping analysys, serial ultrasound scans, ecocardiography and postnatal clinical and genetic evaluation at the Fetal Medicine Unit - Departament of Obstetrics - São Paulo University. The karyotype was abnormal in 14.2% of the cases and normal in 85.8%. At the anomaly scan, 73.1% of the abnormal karyotype and 24.7% of the normal fetuses presented structural abnormalities, one third of these were major malformations with 35.7% of cardiac defects. Adverse pregnancy outcome as miscarriages, intrauterine and neonatal deaths occurred in 76.5% of the abnormal karyotype group and in 10.2% of the normal. 72.7% of the infants with normal karyotype had postnatal examination with 14,8% presenting abnormalities. The chances of having a live and healthy child decreased with increased NT thickness. For NT above 4.5mm this varied from 18.8%, for an unknown karyotype result, to 37.5% for a normal karyotype. The chances of abnormal karyotype increased with NT thickness. In addition, when the karyotype was normal, the frequency of fetal malformations, specially heart defects, adverse pregnancy outcome and postnatal abnormalities increased with NT thickness
36

Avaliação da relação entre os índices vasculares placentários e a exposição individual à poluição atmosférica no primeiro trimestre / Evaluation of the placental vascular indices and individual exposure to air pollution in the first trimester

Karen Hettfleisch 17 February 2016 (has links)
OBJETIVO: Avaliar a influência dos efeitos da poluição atmosférica sobre o volume e a vascularização placentários no primeiro trimestre. MÉTODOS: O presente estudo é uma coorte prospectiva  realizada de outubro de 2011 a março de 2014, em São Paulo, Brasil. Os critérios de inclusão foram: feto único, idade gestacional entre 11 semanas e 13 semanas e 6 dias, ausência de doença materna, ausência de malformações e utilização correta do amostrador passivo individual de poluentes. Os critérios de exclusão foram: gestação gemelar, malformações e abortamento diagnosticados à ultrassonografia, mudança de endereço para fora da área de recrutamento, desistência da paciente, doença materna diagnosticada durante o acompanhamento. A exposição à poluição foi avaliada por 7 a 18 dias, antes da avaliação ultrassonográfica, utilizando-se amostrador passivo individual dos poluentes NO2 e de O3. Após uso do filtro, as gestantes eram avaliadas na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina de São Paulo (FMUSP). Nesse local, elas foram submetidas à ultrassonografia morfológica entre 11 semanas e 13 semanas e 6 dias e à avaliação placentária pela técnica tridimensional associada ao power Doppler. Por meio desse exame foram avaliados quantitativamente o volume da placenta e seus índices vasculares placentários (com o software VOCAL), os quais compreendem: índice de vascularização (IV), índice de fluxo (IF) e índice de vascularização e fluxo (IVF). A influência dos níveis de poluentes na vascularização e volume placentários log-transformada foi analisada utilizando modelos de regressão linear múltipla que controlavam a idade gestacional, índice de massa corpórea, tabagismo, localização da placenta e paridade. RESULTADOS: Foram avaliadas 229 gestantes no primeiro. O aumento dos níveis de NO2 no primeiro trimestre teve um efeito negativo significativo sobre o IV (p = 0,012 e beta = 0,160) e IVF (p = 0,015 e beta = -0,159). Não houve influência de NO2 e O3 no volume placentário ou IF. CONCLUSÃO: A exposição materna ao NO2 foi significativamente associada com diminuição do índice de vascularização e do índice de vascularização e fluxo no primeiro trimestre da gravidez, o que sugere que esse poluente e outros poluentes primários e secundários, os quais estão associados ao NO2, influenciam na placentação, reduzindo sua vascularização / OBJECTIVE: To evaluate the influence of air pollution on the volume and placental vascularization in the first trimester. METHODS: This study is a prospective cohort conducted from October 2011 to March 2014 in São Paulo, Brazil. The inclusion criteria were single fetus, gestational age between 11 weeks and 13 weeks and 6 days, the absence of maternal disease, fetal defects and correct use of passive personal monitors pollutants. The exclusion criteria were twin pregnancy, abortion and malformations diagnosed on ultrasound, change of address out of the area of recruitment, patient abandonment, and maternal disease diagnosed during follow-up. The pollution exposure was evaluated by 7 to 18 days, before the ultrasound evaluation, using passive personal monitors pollutants of NO2 and O3. After using the filter, the pregnant women were evaluated at Obstetrics Department from Hospital das Clinicas of Faculdade de Medicina de São Paulo (FMUSP). In this place, they were subjected to morphological ultrasound between 11 weeks and 13 weeks and 6 days and placental evaluation by the three dimensional ultrasound power Doppler. Through the ultrasound examination were quantitatively evaluated the volume of the placenta and their placental vascular indices (with VOCAL software), which comprise the vascularization index (VI), flow index (FI) and vascularization flow index (VFI). The influence of pollutant levels on logtransformed placental vascularization and volume was analyzed using multiple linear regression models that controlled for gestational age, body mass index, smoking status, placental location and parity. RESULTS: In the first trimester 229 pregnant women were evaluation. NO2 levels increased in the first trimester had a significant negative effect on the VI (p=0.012 and beta= -0.160) and the VFI (p = 0.015 and beta= -0.159). No effect of NO2 and O3 on the log of placental volume or FI was observed. CONCLUSION: NO2 exposure was significantly associated with a diminished Vascularization Index and Vascularization and Flow Index in the first trimester of pregnancy, which suggests that this pollutant and other primary and secondary pollutants that are associated with NO2 influence placentation and decrease vascularization
37

Acompanhamento pré e pós-natal dos casos com translucência nucal fetal aumentada / Prenatal and postnatal Follow-up of cases with increased fetal nuchal translucency thickness

Fatima Aparecida Targino Saldanha 15 December 2004 (has links)
Objetivo: analisar o resultado das gestações e pós-natal dos fetos com translucência nucal (TN) aumentada. Método: Duzentos e setenta e cinco fetos com TN aumentada foram avaliados no setor de Medicina Fetal da Clínica Obstétrica do HC-FMUSP, com análise do cariótipo, ultra-sonografia seriada, ecocardiografias fetal e pós-natal e avaliação clinica genética pós-natal. Resultados: 14,2% apresentaram cariótipos alterados e 85,8% normais. A ultra-sonografia morfológica esteve alterada em 73,1% dos casos com cariótipo anormal e em 24,7% dos normais, destes, um terço apresentou malformações estruturais maiores, sendo 35,7% cardíacas. Resultados gestacionais adversos, como abortamento, óbitos intra-útero e neonatal ocorreram em 76,5% dos fetos com anomalias cromossômicas e em 10,2% com cariótipos normais. A avaliação pós-natal foi realizada em 72,7% das crianças, mostrando-se alterada em 14,8% dos casos. A freqüência de criança viva e saudável diminuiu com a medida da TN, que variou de 37,5%, nos casos com cariótipos normais, a 18,8% com cariótipos desconhecidos, quando a TN foi igual ou maior que 4,5 mm. Conclusão: Quanto maior a TN maior o risco de anomalias cromossômicas e, nos casos com cariótipos normais, maior a freqüência de malformações estruturais, em especial defeitos cardíacos, resultados gestacionais adversos e alterações à avaliação pós-natal / The aim of this study was to evaluate pregnancy and postnatal outcomes in fetuses with increased nuchal translucency thickness (NT). Two hundred seventy five fetuses with increased NT were examined with karyotyping analysys, serial ultrasound scans, ecocardiography and postnatal clinical and genetic evaluation at the Fetal Medicine Unit - Departament of Obstetrics - São Paulo University. The karyotype was abnormal in 14.2% of the cases and normal in 85.8%. At the anomaly scan, 73.1% of the abnormal karyotype and 24.7% of the normal fetuses presented structural abnormalities, one third of these were major malformations with 35.7% of cardiac defects. Adverse pregnancy outcome as miscarriages, intrauterine and neonatal deaths occurred in 76.5% of the abnormal karyotype group and in 10.2% of the normal. 72.7% of the infants with normal karyotype had postnatal examination with 14,8% presenting abnormalities. The chances of having a live and healthy child decreased with increased NT thickness. For NT above 4.5mm this varied from 18.8%, for an unknown karyotype result, to 37.5% for a normal karyotype. The chances of abnormal karyotype increased with NT thickness. In addition, when the karyotype was normal, the frequency of fetal malformations, specially heart defects, adverse pregnancy outcome and postnatal abnormalities increased with NT thickness
38

Avaliação da relação entre os índices vasculares placentários e a exposição individual à poluição atmosférica no primeiro trimestre / Evaluation of the placental vascular indices and individual exposure to air pollution in the first trimester

Hettfleisch, Karen 17 February 2016 (has links)
OBJETIVO: Avaliar a influência dos efeitos da poluição atmosférica sobre o volume e a vascularização placentários no primeiro trimestre. MÉTODOS: O presente estudo é uma coorte prospectiva  realizada de outubro de 2011 a março de 2014, em São Paulo, Brasil. Os critérios de inclusão foram: feto único, idade gestacional entre 11 semanas e 13 semanas e 6 dias, ausência de doença materna, ausência de malformações e utilização correta do amostrador passivo individual de poluentes. Os critérios de exclusão foram: gestação gemelar, malformações e abortamento diagnosticados à ultrassonografia, mudança de endereço para fora da área de recrutamento, desistência da paciente, doença materna diagnosticada durante o acompanhamento. A exposição à poluição foi avaliada por 7 a 18 dias, antes da avaliação ultrassonográfica, utilizando-se amostrador passivo individual dos poluentes NO2 e de O3. Após uso do filtro, as gestantes eram avaliadas na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina de São Paulo (FMUSP). Nesse local, elas foram submetidas à ultrassonografia morfológica entre 11 semanas e 13 semanas e 6 dias e à avaliação placentária pela técnica tridimensional associada ao power Doppler. Por meio desse exame foram avaliados quantitativamente o volume da placenta e seus índices vasculares placentários (com o software VOCAL), os quais compreendem: índice de vascularização (IV), índice de fluxo (IF) e índice de vascularização e fluxo (IVF). A influência dos níveis de poluentes na vascularização e volume placentários log-transformada foi analisada utilizando modelos de regressão linear múltipla que controlavam a idade gestacional, índice de massa corpórea, tabagismo, localização da placenta e paridade. RESULTADOS: Foram avaliadas 229 gestantes no primeiro. O aumento dos níveis de NO2 no primeiro trimestre teve um efeito negativo significativo sobre o IV (p = 0,012 e beta = 0,160) e IVF (p = 0,015 e beta = -0,159). Não houve influência de NO2 e O3 no volume placentário ou IF. CONCLUSÃO: A exposição materna ao NO2 foi significativamente associada com diminuição do índice de vascularização e do índice de vascularização e fluxo no primeiro trimestre da gravidez, o que sugere que esse poluente e outros poluentes primários e secundários, os quais estão associados ao NO2, influenciam na placentação, reduzindo sua vascularização / OBJECTIVE: To evaluate the influence of air pollution on the volume and placental vascularization in the first trimester. METHODS: This study is a prospective cohort conducted from October 2011 to March 2014 in São Paulo, Brazil. The inclusion criteria were single fetus, gestational age between 11 weeks and 13 weeks and 6 days, the absence of maternal disease, fetal defects and correct use of passive personal monitors pollutants. The exclusion criteria were twin pregnancy, abortion and malformations diagnosed on ultrasound, change of address out of the area of recruitment, patient abandonment, and maternal disease diagnosed during follow-up. The pollution exposure was evaluated by 7 to 18 days, before the ultrasound evaluation, using passive personal monitors pollutants of NO2 and O3. After using the filter, the pregnant women were evaluated at Obstetrics Department from Hospital das Clinicas of Faculdade de Medicina de São Paulo (FMUSP). In this place, they were subjected to morphological ultrasound between 11 weeks and 13 weeks and 6 days and placental evaluation by the three dimensional ultrasound power Doppler. Through the ultrasound examination were quantitatively evaluated the volume of the placenta and their placental vascular indices (with VOCAL software), which comprise the vascularization index (VI), flow index (FI) and vascularization flow index (VFI). The influence of pollutant levels on logtransformed placental vascularization and volume was analyzed using multiple linear regression models that controlled for gestational age, body mass index, smoking status, placental location and parity. RESULTS: In the first trimester 229 pregnant women were evaluation. NO2 levels increased in the first trimester had a significant negative effect on the VI (p=0.012 and beta= -0.160) and the VFI (p = 0.015 and beta= -0.159). No effect of NO2 and O3 on the log of placental volume or FI was observed. CONCLUSION: NO2 exposure was significantly associated with a diminished Vascularization Index and Vascularization and Flow Index in the first trimester of pregnancy, which suggests that this pollutant and other primary and secondary pollutants that are associated with NO2 influence placentation and decrease vascularization
39

Expression et régulation des sous-unités beta de l’hCG au cours de la différenciation du trophoblaste humain au premier trimestre de grossesse / Expression and regulation of hCG beta subunit during human trophoblast differentiation in the first trimester of pregnancy

Cocquebert, Mélanie 04 April 2012 (has links)
Le placenta humain est un organe indispensable au maintien de la grossesse et au développement foetal. Son unité structurale et fonctionnelle est la villosité choriale constituée principalement de trophoblastes qui se différencient selon la voie villeuse endocrine ou extravilleuse invasive. Ces deux populations trophoblastiques sécrètent de l'hormone chorionique gonadotrope humaine (hCG), hormone indispensable à la grossesse. C'est une glycoprotéine constituée de deux sous-unités: la sous-unité alpha commune avec la LH, FSH et la TSH et la sous-unité beta, spécifique à chaque hormone, codée par un cluster de gênes regroupés en type I (gêne beta 7) et type II (gênes beta 3, 5 et 8). L'hCG est sécrétée dans le compartiment maternel où elle joue un rôle endocrine essentiel au maintien de la grossesse en stimulant la production de progestérone par l'ovaire. L'hCG joue également un rôle localement en stimulant la différenciation de chaque type de trophoblaste. Elle présente, dans le sang maternel, un pic de sécrétion à 10-12 semaines d'aménorrhée (SA), période ou le statut oxydatif placentaire change. En effet, les bouchons trophoblastiques obstruant la lumière des artères spiralées utérines se délitent à cette période, permettant l'entrée progressive du sang maternel dans la chambre intervilleuse. La pression en oxygène augmente de 18 mm/Hg (8-9 SA, 1er trimestre précoce) à 60 mm/Hg (12-14 SA, 1er trimestre tardif). Dans mon travail de thèse, j'ai cherché à mettre en évidence in situ et in vitro l'impact de ce changement de statut oxydatif sur la différenciation des trophoblastes villeux du 1er trimestre, et plus particulièrement sur l'expression des hCG beta de type I et de type II. J'ai ainsi mis en évidence que les trophoblastes villeux mononucléés du 1er trimestre précoce sécrétaient plus d'hCG beta de type I et II, fusionnaient plus rapidement et exprimaient un panel de facteurs de transcription différents par rapport aux trophoblastes villeux du 1er trimestre tardif. Dans un deuxième temps, j'ai comparé in vitro l'expression et la régulation des deux types d'hCG beta entre les trophoblastes villeux et extravilleux. J'ai montré que: 1) les trophoblastes villeux expriment plus d'hCG beta de type I et II que les trophoblastes extravilleux, 2) dans les deux cas l'hCG beta de type II est majoritaire et 3) PPAR gamma régule de façon opposée ces deux types d'hCG entre les trophoblastes villeux et extravilleux. Enfin j'ai mis en évidence que l'expression de ces deux types d'hCG était dérégulée dans la pré-éclampsie et le RCIU. L'étude des mécanismes impliqués dans la régulation des gênes codants pour l'hCG représente un enjeu important pour la compréhension de la différenciation du trophoblaste humain, du développement précoce du placenta et des pathologies de la grossesse. / The human placenta is an essential organ to maintain pregnancy and for foetal growth. Its structural and functional unit is the chorionic villous, which is mainly composed of cytotrophoblasts that follow two differentiation pathways: the endocrine villous and the invasive extravillous trophoblasts. These two trophoblastic subtypes secrete the human chorionic gonadotropin hormone (hCG), an essential hormone for trophoblast differentiation, placental development and pregnancy. hCG is a glycoprotein composed of two subunits: the alpha subunit, which is common to LH, FSH and TSH, and the beta subunit that confers hormone specificity. A gene cluster encodes the beta subunit, type I (CGB7) and type II (CGB3, 5 and 8), that code for two different proteins. hCG is detected in the maternal blood from the first week of pregnancy, with a peak level at 10-12 weeks of gestation (WG). During the first trimester the oxygen concentration in the intervillous space changes from about 2% (prior to 10 WG) to approximately 6-8% (after 12 WG) due to development of blood flow to the placenta. During my PhD work, I studied in situ and in vitro the impact of these different environments during the first trimester on villous cytotrophoblast differentiation, and more specifically on the type I and type II beta hCG gene expression. I showed that type I and type II beta hCG are more expressed in early first trimester cytotrophoblasts and that these cells exibit more fusion features and express a different panel of transcription factors compare to cells from late first trimester. In the second part of my work, I compared the expression and the regulation in vitro of the two types of beta hCG between villous and extravillous cytotrophoblasts. I demonstrated: 1) villous trophoblast express more type I and type II beta hCG compared to the extravillous trophoblast, 2) in both case type II hCG beta is the major form of beta hCG and 3) PPAR gamma differentially regulates type I and type II beta hCG expression in villous and extravillous trophoblasts. Lastly I showed that the expression of type I and type II beta hCG is deregulated in pre-eclampsia and FGR. The study of the mechanisms involved in hCG regulation represents an important issue for the understanding of human trophoblast differenciation and pregnancy pathophysiology.
40

Avaliação sequencial do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina -símile na predição do parto prematuro / Sequential evaluation of the cervix and test for phosphorylated insulin-like growth factor binding protein-1 in the prediction of preterm delivery

Rolnik, Daniel Lorber 06 November 2013 (has links)
INTRODUÇÃO: O antecedente de parto prematuro espontâneo em gestação anterior é considerado o principal e mais importante fator de risco clínico para prematuridade, principal causa de morbidade e mortalidade neonatal. Cerca de 25% das pacientes que tiveram parto prematuro apresentarão recorrência. A prevenção secundária consiste na pesquisa de marcadores de maior risco, com o intuito de instituir medidas terapêuticas apropriadas e de evitar tratamentos desnecessários. A hipótese do presente estudo é a de que existe correlação entre os resultados da avaliação do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina-símile (phIGFBP-1) e que a utilização de ambos em associação possa predizer a ocorrência de parto prematuro com maior sensibilidade. OBJETIVOS: Averiguar a utilidade da medida do comprimento do colo uterino e do teste para phIGFBP-1 na predição do parto prematuro antes de 37 e de 34 semanas, a existência de relação dos testes entre si, o melhor valor de corte da medida do colo em diferentes idades gestacionais e a melhor época de realização de cada um dos exames. MÉTODO: Foram compilados e submetidos a análise secundária os dados de 101 gestantes com antecedente de parto prematuro atendidas no Setor de Baixo Peso Fetal da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 2003 e 2008. A medida do comprimento cervical e o teste para phIGFBP-1 foram realizados a cada três semanas, entre 24 e 34 semanas de gestação, e comparados com o desfecho de parto prematuro e nascimento com 34 semanas ou menos, e o melhor valor de corte do colo uterino foi estabelecido por meio de curva de características operacionais. RESULTADOS: Das 101 gestações estudadas, 25 (24,8%) terminaram em parto prematuro, das quais 12 (11,9%) ocorreram com 34 semanas ou menos. As idades gestacionais médias de avaliação foram de 24, 27, 30 e 33 semanas, e os valores de corte do colo uterino foram de 22, 21, 20 e 16 mm, respectivamente. A medida do comprimento do colo apresentou maior sensibilidade (cerca de 70%) e foi capaz de predizer o parto prematuro em todas as avaliações. O teste para phIGFBP-1 não foi útil com 24 semanas, porém foi capaz de detectar de forma independente o risco de prematuridade com 27, com 30 e com 33 semanas. Houve associação estatística dos exames entre si, de forma que o comprimento cervical médio foi menor em gestantes com teste positivo para phIGFBP-1. A associação dos exames elevou a sensibilidade e o valor preditivo negativo de forma significativa. CONCLUSÕES: A medida do comprimento do colo pela ultrassonografia transvaginal constitui bom marcador de risco para parto prematuro com 24 semanas, e o teste para phIGFBP-1 é útil após 27 semanas. A associação dos dois exames possui alta sensibilidade e alto valor preditivo negativo em gestantes de alto risco para prematuridade espontânea, e a realização do primeiro com 24 semanas e do segundo com 27 semanas constitui bom modelo preditivo para o parto prematuro / INTRODUCTION: The history of spontaneous preterm birth in a previous pregnancy is considered the main and most important clinical risk factor for preterm birth, the leading cause of neonatal morbidity and mortality. About 25% of these patients will deliver prematurely again. Secondary prevention consists in the search for markers of increased risk, in order to institute appropriate therapeutic actions and to avoid unnecessary treatments. The hypothesis of this study is that there is a correlation between the results of the evaluation of the cervix and the test for phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) and that the use of both in combination can predict the occurrence of preterm delivery with higher sensitivity. OBJECTIVES: To investigate the usefulness of the measurement of the cervical length and phIGFBP-1 rapid test in the prediction of preterm birth before 37 and 34 weeks, the existence of a relationship between the tests themselves, the best cutoff value of cervical length measurement at different gestational ages and the best time to carry out each of the exams. METHODS: Data of 101 women with previous preterm birth assisted at the Obstetrical Clinic of the Hospital das Clínicas, Faculty of Medicine, University of São Paulo between 2003 and 2008 were collected and subjected to secondary analysis. The measurement of cervical length and the phIGFBP-1 test were performed every three weeks, between 24 and 34 weeks gestation, and compared with the outcome of premature birth before 37 and 34 weeks, and the best cutoff value of the cervix was determined by receiver operator characteristic curves. RESULTS: Of the 101 pregnancies studied, 25 (24.8%) ended in preterm birth, of which 12 (11.9%) occurred at 34 weeks or less. The mean gestational age in each evaluation was 24, 27, 30 and 33 weeks, and the cutoff of the cervix were 22, 21, 20 and 16 millimeters, respectively. The measurement of cervical length showed the highest sensitivity (approximately 70%) and was able to predict preterm birth in all evaluations. The phIGFBP-1 test was not useful at 24 weeks, but was able to independently detect the risk of prematurity at 27, 30 and 33 weeks. Statistical association between the exams was observed, so that the mean cervical length was lower in pregnant women testing positive for phIGFBP-1. The combination of both tests significantly increased the sensitivity and negative predictive value. CONCLUSIONS: The measurement of cervical length by transvaginal ultrasound is a good marker of risk for preterm delivery at 24 weeks, and the test for phIGFBP-1 is useful after 27 weeks. The association of the two tests is valuable and shows high sensitivity and high negative predictive value in women at high risk for spontaneous preterm birth, when the first is preformed with 24 weeks, and the second with 27 weeks

Page generated in 0.23 seconds