• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 89
  • 14
  • 8
  • 7
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 274
  • 274
  • 97
  • 93
  • 73
  • 65
  • 50
  • 43
  • 39
  • 31
  • 27
  • 25
  • 24
  • 23
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Applied Visual Analytics in Molecular, Cellular, and Microbiology

Dabdoub, Shareef Majed 19 December 2011 (has links)
No description available.
242

Utveckling av automatiserad urinflödesmätare / Development of an Automated Urine Flow Meter

Mohamed, Abdirahman January 2021 (has links)
Detta kandidatexamensarbete som utförts på uppdrag av ST-läkare i urologi Per Nordlund hade målet att bygga en urinflödesmätare. Eftersökta mätvärden att registrera var tidpunkt för miktionstillfället, mängden urin per tidsenhet (ml/s), flödesmönster, total mikterad volym (ml) samt miktionstid (sek). Urinflödesmätaren syftar till att förbättra initial bedömning samt uppföljning av personer med vattenkastningssvårigheter, en vanlig orsak till sjukvårdskontakt hos svenska män. För utvärdering av patienters vattenkastning ombeds patienten idag själv registrera och mäta urinvolym, en metod som ofta innebär besvär för patienten och kan innehålla inkomplett och felaktig data. Vid urologmottagningar ges möjligheten att elektroniskt mäta urinflöde och volym. Då en stor variation över dygn och miktionstillfälle föreligger kan en felaktig bild över symtom presenteras. Detta har gett upphov till idén att skapa en urinflödesmätare vars uppgift är att automatisera mätningsprocessen i hemmet.  Arbetet utfördes genom att programmera en Arduino mikrokontroller samt användning av en flödessensor. Flödessensorns konstruktion bestod av en magnet, halleffektsensor samt en turbin. Halleffektsensorns uppgift var att mäta det elektriska fältet som uppstår då magneten som sitter på flödessensorns turbin roterar. Genom att utnyttja turbinrotationen kan bland annat volym beräknas. Arbetet har även inneburit användning av Python med syftet att spara det mätvärde från mikrokontrollern i en CSV fil som kan öppnas av en vårdgivare med applikationer som Excel. / This bachelor's degree project which was carried out on behalf of Per Nordlund, urology resident, had the goal of building a urine flow meter. The sought-after values to register each time of the micturition; the amount of urine per unit time (ml/ s), flow pattern, total micturized volume (ml) and micturition time (sec). The urine flow meter aims to improve initial assessment and follow-up of people with urination difficulties, a common cause of medical contact in Swedish men. Today, when evaluating patients urination, the patient is asked to register and measure urine volume themselves, a method that often causes problems for the patient and may contain incomplete and incorrect data. At urology clinics, individuals are given the opportunity to electronically measure urine flow and volume. When there is a large variation over day and occasion of micturition, an incorrect picture of symptoms can be presented. This has given rise to the idea of creating a urine flow meter whose task is to automate the measurement process in the home.  The work was performed by programming an Arduino microcontroller and using a flow sensor. The design of the flow sensor consisted of a magnet, a hall-effect sensor and a turbine. The task of the hall-effect sensor was to measure the electric field that arises when the magnet attached on the flow sensor's turbine rotates. By utilizing the turbine rotation, volume can be calculated. The work has also involved the use of Python with the aim of saving the output values from the microcontroller in a CSV file that can be opened by a healthcare provider with applications such as Excel.
243

Évaluation de l’utilité clinique d’une méthode de dépistage de l’hématurie féline

Khenifar, Elodie 03 1900 (has links)
No description available.
244

Estudo comparativo entre microesferas de 100-300um e 300-500um utlizadas na embolização das artérias prostáticas para o tratamento dos sintomas urinários decorrentes da hiperplasia prostática benigna / A comparative study between microspheres of 100-300 um and 300-500 um used in prostatic artery embolization for the treatment of urinary symptoms of benign prostatic hyperplasia

Octavio Meneghelli Galvão Gonçalves 05 February 2018 (has links)
Introdução: O desenvolvimento de novos procedimentos cirúrgicos minimamente invasivos para o tratamento dos sintomas do trato urinário inferior (LUTS), relacionados à hiperplasia prostática benigna (HPB), está se tornando importante campo de pesquisa, na medida em que tenta minimizar os efeitos adversos e complicações decorrentes dos tratamentos convencionais. A embolização das artérias prostáticas (EAP) vem sendo utilizada como alternativa para o tratamento de pacientes com HPB. O objetivo deste trabalho é avaliar e comparar a segurança e eficácia da EAP para o tratamento dos LUTS em pacientes com HPB, utilizando microesferas (Embospheres®) de 100-300 um e 300-500 um. Métodos: Realizou-se estudo de ensaio clínico fase II, prospectivo, no período entre agosto de 2011 e junho de 2013, pela Disciplina de Urologia e Departamento de Radiologia do HCFMUSP. O protocolo de pesquisa foi aprovado pela Comissão de Ética para Análise de Projetos de Pesquisa (CAPPesq) do HCFMUSP. Foram selecionados 30 pacientes com sintomas moderados ou graves (IPSS > 7), refratários ao tratamento clínico para HPB, com volume prostático entre 30g e 100g pela ressonância magnética (RM). Foram excluídos os pacientes com câncer de próstata comprovado por biópsia; prostatite ou infecção ativa do trato urinário; cirurgia ou intervenção prévia para HPB; doença com impacto sobre funcionamento da bexiga; impossibilidade para realizar RM; e distúrbio de coagulação não corrigido clinicamente. Os pacientes foram avaliados de acordo com os sintomas clínicos (IPSS e QoL), toque retal, exames laboratoriais de rotina incluindo o antígeno prostático específico (PSA), urofluxometria livre (Qmax) e RM em diferentes períodos de acompanhamento. Os procedimentos foram realizados no Serviço de Radiologia Intervencionista do HCFMUSP, por meio de punção unilateral da artéria femoral comum, sob anestesia local, usando-se microcateter, agente embolizante do tipo microesferas 100-300 ?m em 15 pacientes (Grupo A) e 300-500 ?m em 15 pacientes (Grupo B). Foi considerado sucesso técnico a identificação, cateterismo e embolização bilateral das artérias prostáticas. Definiu-se como sucesso clínico a retirada da sonda vesical nos pacientes em retenção urinária, melhora dos sintomas de acordo com o escore IPSS < 8 e índice QoL < 3. Considerou-se o valor de p < 0,05 como estatisticamente significante. Resultados: Sucesso técnico foi obtido em todos os casos. Ambos os grupos apresentaram melhoria significativa do IPSS, QoL e do Qmax, assim como redução do PSA e do volume prostático em relação aos dados demográficos (p < 0,05). Houve um aumento volumétrico prostático significativo entre 3 e 12 meses no grupo A (p < 0,05). As diferenças observadas entre os dois grupos não foram significativas, com maior ocorrência de eventos adversos (p = 0,066) e maior redução do PSA no acompanhamento de 3 meses (p = 0,056) nos pacientes tratados com microesferas de 100-300 um. Conclusão: As microesferas de 100-300 ?m e 300-500 um demonstraram serem agentes embolizantes seguros e eficazes na EAP para o tratamento dos LUTS relacionados à HPB. Embora os resultados clínicos e por imagem não tenham diferido significativamente entre os grupos de estudo, os pacientes tratados com 100-300 um apresentaram mais eventos adversos do que aqueles tratados com 300-500 um. O volume da próstata aumentou significativamente entre o terceiro e o décimo segundo mês após EAP no grupo tratado com microesferas 100-300 um, embora se mantivesse significativamente menor que antes da EAP / Introduction: The development of new minimally invasive surgical procedures for the treatment of low urinary tract symptoms (LUTS), related to benign prostatic hyperplasia (BPH), is becoming an important field of research as it attempts to minimize adverse effects and complications resulting from conventional treatments. Prostatic artery embolization (PAE) is increasingly being used as an alternative for the treatment of patients with BPH. The aim of this study was to evaluate and compare the safety and efficacy of PAE for the treatment of LUTS in patients with BPH, using microspheres (Embosphere®) of 100-300 um and 300-500 um. Methods: A prospective Phase II clinical trial was conducted between August 2011 and June 2013 by the Urology Department and the Radiology Department. The research protocol was approved by the Ethics Committee for Analysis of Research Projects (CAPPesq) of HC-FMUSP. In fact, 30 patients with moderate or severe symptoms (IPSS > 7), refractory to the clinical treatment for BPH, with a prostatic volume of 30 g and 100 g were selected by magnetic resonance imaging (MRI). Patients with the following conditions were excluded from the study: biopsy-proven prostate cancer; prostatitis or active urinary tract infection; surgery or previous intervention for BPH; diseases affecting the bladder function; impossibility to perform MRI; and clinically uncorrected coagulation disorders. Patients were evaluated according to clinical symptoms (IPSS and QoL), rectal examination, laboratory tests (PSA), uroflowmetry (Qmax) and imaging (MR) at different follow-up periods. Procedures were performed at the interventional radiology suite of the HCFMUSP, by means of unilateral puncture of the common femoral artery, under local anesthesia, using a microcatheter, microspheres type 100-300 um in 15 patients (Group A) and 300-500 um in 15 patients (Group B). Identification, catheterization and bilateral embolization of the prostatic arteries were considered technical success. Clinical success was defined as the removal of the bladder catheter and improvement of symptoms according to the IPSS score < 8 and QoL index < 3. Results: The PAE was technically successful in all cases. Both groups showed a significant improvement in IPSS, QoL and Qmax, as well as reduction of PSA and prostate volume in relation to demographic data (p < 0.05). There was a significant prostatic volumetric increase between 3 and 12 months in group A (p < 0.05). Differences observed between the two groups were not significant, with a higher number of adverse events (p = 0.066) and lower level of blood PSA at 3 months follow-up (p = 0.056) in Group A (100-300 um). Conclusion: Microspheres of 100-300 ?m and 300-500 ?m are safe and effective embolic agents in PAE for the treatment of LUTS related to BPH. Although functional results did not differ significantly between study groups, patients treated with 100-300 ?m reported more adverse events than those treated with 300-500 um. The prostate volume increased significantly between the third and the twelfth month post-PAE in the group treated with 100-300 um microspheres, although it remained significantly lower than pre-PAE
245

Biofeedback EMG ou eletroestimulação transcutânea parassacral em crianças com disfunção do trato urinário inferior: estudo prospectivo e randomizado / EMG Biofeedback or parasacral transcutaneous eletrical nerve stimulation in children with lower urinary tract dysfunction: study prospective randomized

Reis, Joceara Neves dos 30 November 2015 (has links)
INTRODUÇÃO: A disfunção do trato urinário inferior (DTUI) pode decorrer de contrações vesicais durante a fase de enchimento (hiperatividade do detrusor) ou a falta de coordenação entre a contração vesical e o relaxamento dos músculos do assoalho pélvico durante o esvaziamento vesical (disfunção miccional). Várias publicações sugerem benefícios do uso de biofeedback eletromiográfico (EMG) e eletroestimulação transcutânea parassacral (ENTP) no tratamento destas condições. Contudo faltam estudos controlados comparando estas duas formas de tratamento. OBJETIVO: Comparar a eficácia das técnicas de biofeedback EMG e ENTP em crianças com DTUI. MÉTODOS: Estudo prospectivo e randomizado com 64 crianças, sendo 43 meninas e 21 meninos com idade média 9,39 anos. As crianças foram divididas em dois grupos de tratamento: grupo biofeedback (GB) e grupo de ENTP (GE). Os critérios para avaliar a eficácia do tratamento foram a taxa de resolução dos sintomas noturnos e diurnos, comprovados por diário miccional, urofluxometria, questionários (DVSS - Dysfunction voiding symptoms score), avaliação da qualidade de vida (QV), melhora da constipação e do número de episódios de infecção do trato urinário (ITU).RESULTADOS: No GB 54,9% das crianças tiveram resposta completa e no GE 60,6% em relação a melhora diurna (p=0,483) e 29,6% e 25% em relação a melhora noturna respectivamente (p=0,461). Em relação ao diário miccional, urofluxometria e DVSS, ambos os grupos tiveram melhora estatisticamente significante (p=0,001), porém a QV não teve diferença entre os grupos (p=0,959 e p=0,065). Na avaliação da constipação, houve decréscimo no GB de 61,3% para 19,4% (p=0,002) e no GE de 33,3% para 6,2% (p=0,013). Nenhuma criança apresentou ITU após o término do tratamento (p < 001). CONCLUSÃO: O biofeedback EMG e a ENTP são efetivos para o tratamento de DTUI.Esta eficácia se traduz por melhora dos sintomas diurnos e noturnos bem como na avaliação feita por questionário e urofluxometria. Ambas as técnicas se mostrarm eficazes, embora o biofeedback tenha requerido um menor número de sessões / INTRODUCTION: The lower urinary tract dysfunction (LUTD) may be due to bladder contractions during the filling phase (detrusor overactivity) or the lack of coordination between bladder contraction and relaxation of the pelvic floor muscles during bladder emptying (voiding dysfunction ). Several publications have suggested benefits of using electromyographic biofeedback (EMG) and parasacral transcutaneous electrical nerve stimulation (TENS) in treating these conditions. However there is a lack of controlled studies comparing these two forms of treatment. OBJECTIVE: To compare the effectiveness of EMG biofeedback and parasacral TENS techniques in children with DTUI. METHODS: A prospective and randomized study with 64 children, 43 girls and 21 boys, mean age 9.39 years. The children were divided into two treatment groups: biofeedback group and parasacral TENS. The criteria for assessing the effectiveness of techniques were the rate of resolution of daytime and nighttime symptoms, improvements in voiding diary, uroflowmetry and questionnaires. (DVSS - Dysfunction voiding symptoms score). We also acessed changes in quality of life (QOL) constipation and number of episodes of lower urinary tract infection (UTI). RESULTS: GB 54.9% of children had complete response in EMG biofeedback group and 60.6% in those treated by parasacral TENS in daytime symptoms (p = 0.483) and 29.6% and 25% in night time respectively (p = 0.461). Regarding the voiding diary, uroflowmetry and DVSS, both groups had statistically significant improvement (p = 0.001), but the QOL showed no difference between groups (p = 0.959 and p = 0.065). In the evaluation of constipation, there was a decrease in EMG biofeedback group 61.3% to 19.4% (p = 0.002) and in parasacral TENS group 33.3% to 6.2% (p = 0.013). No child had UTI after the end of treatment (p <.001). CONCLUSION: EMG biofeedback and the parasacral TENS are effective for treating DTUI. This efficiency translates into improved daytime and nighttime symptoms as well as in the evaluation made by questionnaire and uroflowmetry. Both techniques showed excellent results, although biofeedback required a fewer number of sessions
246

Estudo comparativo entre microesferas de 100-300um e 300-500um utlizadas na embolização das artérias prostáticas para o tratamento dos sintomas urinários decorrentes da hiperplasia prostática benigna / A comparative study between microspheres of 100-300 um and 300-500 um used in prostatic artery embolization for the treatment of urinary symptoms of benign prostatic hyperplasia

Gonçalves, Octavio Meneghelli Galvão 05 February 2018 (has links)
Introdução: O desenvolvimento de novos procedimentos cirúrgicos minimamente invasivos para o tratamento dos sintomas do trato urinário inferior (LUTS), relacionados à hiperplasia prostática benigna (HPB), está se tornando importante campo de pesquisa, na medida em que tenta minimizar os efeitos adversos e complicações decorrentes dos tratamentos convencionais. A embolização das artérias prostáticas (EAP) vem sendo utilizada como alternativa para o tratamento de pacientes com HPB. O objetivo deste trabalho é avaliar e comparar a segurança e eficácia da EAP para o tratamento dos LUTS em pacientes com HPB, utilizando microesferas (Embospheres®) de 100-300 um e 300-500 um. Métodos: Realizou-se estudo de ensaio clínico fase II, prospectivo, no período entre agosto de 2011 e junho de 2013, pela Disciplina de Urologia e Departamento de Radiologia do HCFMUSP. O protocolo de pesquisa foi aprovado pela Comissão de Ética para Análise de Projetos de Pesquisa (CAPPesq) do HCFMUSP. Foram selecionados 30 pacientes com sintomas moderados ou graves (IPSS > 7), refratários ao tratamento clínico para HPB, com volume prostático entre 30g e 100g pela ressonância magnética (RM). Foram excluídos os pacientes com câncer de próstata comprovado por biópsia; prostatite ou infecção ativa do trato urinário; cirurgia ou intervenção prévia para HPB; doença com impacto sobre funcionamento da bexiga; impossibilidade para realizar RM; e distúrbio de coagulação não corrigido clinicamente. Os pacientes foram avaliados de acordo com os sintomas clínicos (IPSS e QoL), toque retal, exames laboratoriais de rotina incluindo o antígeno prostático específico (PSA), urofluxometria livre (Qmax) e RM em diferentes períodos de acompanhamento. Os procedimentos foram realizados no Serviço de Radiologia Intervencionista do HCFMUSP, por meio de punção unilateral da artéria femoral comum, sob anestesia local, usando-se microcateter, agente embolizante do tipo microesferas 100-300 ?m em 15 pacientes (Grupo A) e 300-500 ?m em 15 pacientes (Grupo B). Foi considerado sucesso técnico a identificação, cateterismo e embolização bilateral das artérias prostáticas. Definiu-se como sucesso clínico a retirada da sonda vesical nos pacientes em retenção urinária, melhora dos sintomas de acordo com o escore IPSS < 8 e índice QoL < 3. Considerou-se o valor de p < 0,05 como estatisticamente significante. Resultados: Sucesso técnico foi obtido em todos os casos. Ambos os grupos apresentaram melhoria significativa do IPSS, QoL e do Qmax, assim como redução do PSA e do volume prostático em relação aos dados demográficos (p < 0,05). Houve um aumento volumétrico prostático significativo entre 3 e 12 meses no grupo A (p < 0,05). As diferenças observadas entre os dois grupos não foram significativas, com maior ocorrência de eventos adversos (p = 0,066) e maior redução do PSA no acompanhamento de 3 meses (p = 0,056) nos pacientes tratados com microesferas de 100-300 um. Conclusão: As microesferas de 100-300 ?m e 300-500 um demonstraram serem agentes embolizantes seguros e eficazes na EAP para o tratamento dos LUTS relacionados à HPB. Embora os resultados clínicos e por imagem não tenham diferido significativamente entre os grupos de estudo, os pacientes tratados com 100-300 um apresentaram mais eventos adversos do que aqueles tratados com 300-500 um. O volume da próstata aumentou significativamente entre o terceiro e o décimo segundo mês após EAP no grupo tratado com microesferas 100-300 um, embora se mantivesse significativamente menor que antes da EAP / Introduction: The development of new minimally invasive surgical procedures for the treatment of low urinary tract symptoms (LUTS), related to benign prostatic hyperplasia (BPH), is becoming an important field of research as it attempts to minimize adverse effects and complications resulting from conventional treatments. Prostatic artery embolization (PAE) is increasingly being used as an alternative for the treatment of patients with BPH. The aim of this study was to evaluate and compare the safety and efficacy of PAE for the treatment of LUTS in patients with BPH, using microspheres (Embosphere®) of 100-300 um and 300-500 um. Methods: A prospective Phase II clinical trial was conducted between August 2011 and June 2013 by the Urology Department and the Radiology Department. The research protocol was approved by the Ethics Committee for Analysis of Research Projects (CAPPesq) of HC-FMUSP. In fact, 30 patients with moderate or severe symptoms (IPSS > 7), refractory to the clinical treatment for BPH, with a prostatic volume of 30 g and 100 g were selected by magnetic resonance imaging (MRI). Patients with the following conditions were excluded from the study: biopsy-proven prostate cancer; prostatitis or active urinary tract infection; surgery or previous intervention for BPH; diseases affecting the bladder function; impossibility to perform MRI; and clinically uncorrected coagulation disorders. Patients were evaluated according to clinical symptoms (IPSS and QoL), rectal examination, laboratory tests (PSA), uroflowmetry (Qmax) and imaging (MR) at different follow-up periods. Procedures were performed at the interventional radiology suite of the HCFMUSP, by means of unilateral puncture of the common femoral artery, under local anesthesia, using a microcatheter, microspheres type 100-300 um in 15 patients (Group A) and 300-500 um in 15 patients (Group B). Identification, catheterization and bilateral embolization of the prostatic arteries were considered technical success. Clinical success was defined as the removal of the bladder catheter and improvement of symptoms according to the IPSS score < 8 and QoL index < 3. Results: The PAE was technically successful in all cases. Both groups showed a significant improvement in IPSS, QoL and Qmax, as well as reduction of PSA and prostate volume in relation to demographic data (p < 0.05). There was a significant prostatic volumetric increase between 3 and 12 months in group A (p < 0.05). Differences observed between the two groups were not significant, with a higher number of adverse events (p = 0.066) and lower level of blood PSA at 3 months follow-up (p = 0.056) in Group A (100-300 um). Conclusion: Microspheres of 100-300 ?m and 300-500 ?m are safe and effective embolic agents in PAE for the treatment of LUTS related to BPH. Although functional results did not differ significantly between study groups, patients treated with 100-300 ?m reported more adverse events than those treated with 300-500 um. The prostate volume increased significantly between the third and the twelfth month post-PAE in the group treated with 100-300 um microspheres, although it remained significantly lower than pre-PAE
247

Infecção urinária comunitária: aspectos epidemiológicos, clínicos e laboratoriais em crianças e adolescentes / Community-acquired urinary tract infection: epidemiological, clinical and laboratory aspects in children and adolescents

Lo, Denise Swei 31 October 2017 (has links)
INTRODUÇÃO: Infecção do trato urinário (ITU) é doença cujos sinais e sintomas são frequentemente inespecíficos, especialmente em lactentes. Portanto, o conhecimento de seus aspectos epidemiológicos, clínicos e laboratoriais são relevantes para a adequada abordagem clínica. OBJETIVOS PRINCIPAIS: Descrever: a prevalência de ITU como motivo de atendimento em pronto-socorro geral de Pediatria; a variabilidade da frequência de ITU e dos agentes etiológicos em diversas faixas etárias e sexo; o perfil de sensibilidade antimicrobiana de Escherichia coli; o quadro clínico, laboratorial e evolutivo de lactentes jovens. OBJETIVOS SECUNDÁRIOS: Cálculo de sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do corte de leucocitúria >= 10.000 leucócitos/mL para o diagnóstico de ITU em lactentes jovens. Comparar as diferenças de ITU por Escherichia coli e Staphylococcus saprophyticus em adolescentes do sexo feminino e discutir as melhores escolhas de terapia antimicrobiana empírica para uso na população estudada. MÉTODO: Estudo retrospectivo, descritivo, incluindo todos os casos de ITU (urocultura quantitativa com >= 50.000 UFC/mL por sondagem vesical ou >= 100.000 UFC/mL por jato médio) atendidos no Pronto-Socorro de Pediatria do Hospital Universitário da Universidade de São Paulo, de 01/01/2010 a 31/12/2012, idades entre zero a 15 anos incompletos. Resultados: Do total de 188.460 atendimentos realizados, 7994 colheram urocultura por suspeita de ITU; este diagnóstico foi confirmado em 1071 casos (prevalência: 0,57% do total de atendimentos e 13,4% das uroculturas incluídas). A proporção de casos entre sexo masculino e feminino foi: 1:0,3 em menores de três meses; 1:3,9 entre três meses a 12 anos e 1:12 entre 12 a 15 anos. Escherichia coli foi o principal agente responsável por 73,2% dos casos totais de ITU. Entretanto, outros agentes importantes foram Klebsiella pneumoniae (18,46%) e Enterococcus faecalis (7,7%) em lactentes jovens (menores de três meses de idade); Proteus mirabilis (30,8%) em meninos de três meses a 12 anos; Staphylococcus saprophyticus (25%) em adolescentes do sexo feminino entre 12 a 15 anos. A sensibilidade antimicrobiana de Escherichia coli foi observada acima de 80% para: amoxicilina/ácido clavulânico (87%), cefuroxima (98%), cefotaxima (98%), ceftriaxona (100%), cefepime (99%), amicacina (100%), gentamicina (97%), ciprofloxacina (98%), norfloxacina (94%), ácido nalidíxico (93%) e nitrofurantoína (97%). Em lactentes jovens, febre sem sinais localizatórios foi o sintoma mais frequente de ITU (77,8%). Exames subsidiários de hemograma e proteína C reativa foram de pouca utilidade clínica. O teste de nitrito positivo apresentou baixa sensibilidade: 30,8% (IC 95%: 19,9%-43,4%), porém elevada especificidade e valor preditivo positivo. Enquanto que o corte de leucocitúria > 10.000 leucócitos/mL para ITU revelou boa sensibilidade: 87,7% (IC 95%: 77,2%-94,5%), porém baixa especificidade e valor preditivo positivo. Nas adolescentes do sexo feminino entre 12 a 15 anos, houve menor positividade do teste do nitrito nas ITU por Staphylococcus saprophyticus do que nas ITU por Escherichia coli. Na população do presente estudo, a terapia empírica inicial recomendada seria: zero a três meses: tratamento parenteral com aminoglicosídeo ou cefalosporina de terceira geração; podendo associar ampicilina para cobertura de Enterococcus faecalis. Entre três meses a 15 anos: amoxicilina/ácido clavulânico ou cefuroxima ou ceftriaxona ou aminoglicosídeos. CONCLUSÕES: ITU é doença frequente em atendimentos de pronto-socorro. Os aspectos epidemiológicos, clínicos e laboratoriais são variáveis nas diversas faixas etárias e sexos; portanto, a abordagem deve ser individualizada em cada um destes segmentos / INTRODUCTION: Urinary tract infection (UTI) frequently presents with nonspecific signs and symptoms, particularly in infants. Therefore, the understanding of its epidemiological, clinical and laboratory aspects are relevant to its appropriate clinical approach. MAIN OBJECTIVES: To describe: the prevalence of UTI as a cause for attending the pediatric emergency department; the variability of the frequency of UTI and etiological agents in different age groups and sexes; the antimicrobial sensitivity profile of Escherichia coli; the clinical features, laboratory findings and treatment outcomes in young infants. SECONDARY OBJECTIVES: To evaluate sensitivity, specificity, positive predictive value and negative predictive value of pyuria >= 10,000 leukocytes/mL for screening UTI in young infants. To compare UTI due to Escherichia coli with UTI due to Staphylococcus saprophyticus in female adolescents and to discuss the best empirical antimicrobial treatment in the population studied. METHODS: Retrospective, descriptive study, including all cases of UTI (urine culture of >= 50,000 CFU/mL obtained by bladder catheterization or >= 100,000 CFU/mL obtained by midstream-voided method) attended at the pediatric emergency department of University Hospital of the University of São Paulo, from 01/01/2010 to 12/31/2012, ages from zero to 15 years old. Results: Of 188,460 visits in this period, 7994 collected urine culture on suspicion of UTI. This diagnosis was confirmed in 1071 cases (prevalence: 0.57% of total visits and 13.4% of urine cultures included). The proportion of cases between male and female was: 1: 0.3 in children younger than three months old; 1: 3.9 from three months to 12 years old and 1:12 from 12 to 15 years old. Escherichia coli was the main etiology responsible for 73.2% of total cases of UTI. However, other important agents were Klebsiella pneumoniae (18.46%) and Enterococcus faecalis (7.7%) in young infants (under three months of age); Proteus mirabilis (30.8%) in boys from three months to 12 years old; Staphylococcus saprophyticus (25%) in female adolescents aged 12-15 years. The antimicrobial sensitivity of Escherichia coli was still above 80% for amoxicillin / clavulanic acid (87%), cefuroxime (98%), cefotaxime (98%), ceftriaxone (100%), cefepime (99%), amikacin (100%), gentamicin (97%), ciprofloxacin (98%), norfloxacin (94%), nalidixic acid (93%) and nitrofurantoin (97%). In young infants, the absence of another source of fever was the most frequent UTI symptom (77.8%). Laboratory parameters including peripheral white blood cell count and C-reactive protein concentration were of limited clinical usefulness. The sensitivity of nitrite testing for bacteriuria was low: 30.8% (95% CI: 19.9%-43.4%), but had high specificity and positive predictive value. Pyuria> 10,000 leukocytes / mL for identifying UTI had high sensitivity: 87.7% (95% CI: 77.2%-94.5%), but low specificity and positive predictive value. In female adolescents aged 12 to 15 years old, there were few positive nitrite tests in UTI due to Staphylococcus saprophyticus compared with UTI due to Escherichia coli. In the population studied, the initial empirical therapy recommended would be: from zero to three months old: parenteral treatment with aminoglycoside or third generation cephalosporin; it could be associated with ampicillin to treat Enterococcus faecalis. Between three months to 15 years old: amoxicillin / clavulanic acid or cefuroxime or ceftriaxone or aminoglycosides. In cystitis: in addition to amoxicillin / clavulanic acid or cefuroxime; nitrofurantoin is also a good option for Staphylococcus saprophyticus UTI whereas nalidixic acid is also a nice choice for Proteus mirabilis UTI. CONCLUSIONS: UTI is a common disease in emergency department visits. The epidemiological, clinical and laboratory aspects are variable in the different age and sex groups; therefore, the approach must be individualized in each of these groups
248

Conception et Réalisation de Capteurs et de Biocapteurs Électrochimiques à Base de Nanomatériaux pour le Contrôle de la Qualité en Agroalimentaire et pour l'Analyse Biomédicale / Design and Achievement of Electrochemical Sensors and Biosensors Based on Nanomaterials for Food Quality Control and Biomedical Analysis

El Alami el Hassani, Nadia 19 December 2018 (has links)
Au cours des dernières décennies, les capteurs et les biocapteurs électrochimiques ont connu un développement considérable en raison de leur simplicité, fiabilité, rapidité et sélectivité. Ils ont constitué les alternatives les plus séduisantes pour les méthodes analytiques classiques dans des domaines aussi variés que l'agro-alimentaire, la médecine et la biologie clinique, ou le contrôle de la qualité de l'environnement. Dans ce travail de recherche, nous nous sommes intéressés, dans un premier volet, aux développements des immunocapteurs et capteurs électrochimiques à base des polymères à empreintes moléculaires (MIPs) pour le contrôle de la qualité des miels. La première partie de ce volet concerne le développement des immunocapteurs sur des structures dites Bio-MEMS basées sur des microélectrodes en or. L'élaboration de ces immunocapteurs a été dédiée à la détection des résidus d'antibiotiques à savoir la sulfapyridine (SPy) et la tétracycline (TC). Une nouvelle structure des nanoparticules magnétiques (MNPs) revêtues du copolymère poly (acide pyrrole-co-pyrrole-2-carboxylique) a été exploitée dans ces travaux pour leur réseau d'immobilisation tridimensionnel ainsi que pour leur stabilité pendant de longues périodes. La détection de la SPy et de la TC a été réalisée par différentes approches compétitives en utilisant des anticorps polyclonaux. Dans la deuxième partie de ce volet, nous avons fabriqué des capteurs à base des MIPs pour la détection de la sulfaguanidine, la doxycycline et le chloramphénicol dans le miel. Ces dispositifs ont été développés sur la surface des électrodes sérigraphiées en or en employant une matrice polymérique du polyacrylamide en présence des molécules empreintes. Les performances de ces capteurs et biocapteurs (limite de détection, sélectivité, reproductibilité, application dans les milieux réels) ont ensuite été évaluées. Dans un deuxième volet, nous nous sommes parvenus à appliquer un dispositif de la langue électronique voltammétrique (Langue-EV) pour des analyses agroalimentaires et biomédicales. Dans un premier temps, nous avons discriminé les miels issus de quatorze régions de la France et du Maroc par le dispositif de la Langue-EV. Nous nous sommes aussi parvenus à démontrer la fiabilité de ce dispositif à prédire les résultats des différents paramètres physico-chimiques d'après les réponses des méthodes analytiques utilisées. Dans un deuxième temps, nous sommes passés à l'application du dispositif de la Langue-EV en analyse biomédicale dans le but de discriminer les urines des patientes souffrants des infections urinaires avec celles des femmes saines / In recent decades, the use of electrochemical sensors and biosensors have grown considerably due to their simplicity, reliability, rapidity, and selectivity. They were the most attractive alternative tools for conventional analytical methods in various fields such as food control, medicine, and clinical biology or environmental control. In this research works, we focused, in the first part, on the development of immunosensors and electrochemical sensors based on molecularly imprinted polymers (MIPs) for the quality control of honey. In the second part, we managed to apply a voltammetric electronic tongue (VE-tongue) for food monitoring and biomedical analyzes. The first part of our research work concerns the development of immunosensors based on gold microelectrodes of the Bio-MEMS devices. The development of these immunosensors was dedicated to the detection of antibiotic residues namely sulfapyridine (SPy) and tetracycline (TC). A new structure of magnetic nanoparticles (MNPs) coated with the poly (pyrrole-co-pyrrole-2-carboxylic acid) copolymer has been exploited in this work for their three-dimensional immobilization network as well as for their stability for long periods. The detection of SPy and TC was performed by different competitive approaches using polyclonal antibodies. In this part, we have also synthesized the MIP sensors dedicated to the detection of sulfaguanidine, doxycycline, and chloramphenicol in honey. These devices have been developed on the surface of the screen-printed gold electrodes by employing a polyacrylamide matrix in the presence of the target molecules. The performances of these sensors and biosensors (limit of detection, selectivity, reproducibility, applications in real samples) were then evaluated. Regarding the second part of our research works, it involved the discrimination between honeys from fourteen regions from France and Morocco. We have succeeded in demonstrating the reliability of this device in predicting the results of the different physico-chemical parameters of honey samples according to the responses of the used analytical methods. In other steps, we proceeded to the application of the VE-tongue in biomedical analyzes to discriminate urine specimens of patients suffering from urinary tract infections and those of healthy subjects
249

Avaliação clínico-laboratorial da obstrução uretral em felinos domésticos

Schaefer, Gabriela da Cruz January 2017 (has links)
A obstrução uretral é uma condição clínica comum em gatos, caracterizada por alterações metabólicas e do equilíbrio hidroeletrolítico e ácido-básico que são potencialmente fatais. Dentre as causas de obstrução uretral, a cistite idiopática é a mais frequentemente observada em diversos estudos. Outras causas incluem urolitíase, tampões uretrais e infecção do trato urinário. Em muitos casos, os gatos encontram-se em estado crítico e a morte pode ocorrer em decorrência de alterações metabólicas, como estado urêmico avançado e hipercalemia. As principais alterações eletrolíticas e do equilíbrio ácido-básico relatadas são hipercalemia, acidose metabólica, hiponatremia e hipocalcemia ionizada. Embora a obstrução uretral seja muito frequente na rotina clínica, estudos para caracterizar a população de gatos acometida ainda são escassos no Brasil. Características relacionadas ao manejo, dieta e perfil dos tutores podem influenciar na manifestação da doença. Os objetivos do presente estudo foram avaliar os parâmetros clínicos e as alterações hematológicas, bioquímicas, urinárias, eletrolíticas e ácido-básicas presentes em gatos com obstrução uretral e a associação entre estas variáveis. Além disso, objetivou-se conhecer as principais causas de obstrução uretral nos gatos atendidos no Hospital de Clínicas Veterinárias da Universidade Federal do Rio Grande do Sul. Para isso, foram incluídos no estudo 28 gatos com diagnóstico de obstrução uretral no período de dezembro de 2015 a dezembro de 2016. Foram obtidos dados referentes ao histórico, exame físico, coletados sangue e urina, além da realização de exames de imagem (radiografia e ultrassonografia abdominal). Em todos os gatos foram realizados hemograma, bioquímica sérica, análise de pH, gases e eletrólitos sanguíneos, urinálise e urocultura. Após, todos os pacientes foram tratados de acordo com um protocolo pré-estabelecido. A causa mais comum de obstrução uretral neste estudo foi a cistite idiopática, que ocorreu em mais de 60% dos casos, seguida de tampões uretrais e infecção do trato urinário. Nenhum caso de urolitíase foi diagnosticado, o que pode ser explicado por fatores como idade, ambiente e estilo de vida dos animais. A maioria dos gatos obstruídos apresentou múltiplos sinais sistêmicos, assim como alterações metabólicas, eletrolíticas e do equilíbrio ácido-básico, principalmente azotemia, hiperlactatemia, acidose metabólica, hipercalemia e hipocalcemia ionizada. Hipotermia, depressão do estado mental, bradicardia e desidratação foram os parâmetros clínicos que tiveram maior quantidade de associação com as alterações metabólicas e podem ser considerados bons preditores clínicos destas desordens. Por outro lado, o lactato não foi considerado um bom preditor de alterações clínicas e laboratoriais neste estudo. / Urethral obstruction is a common and potentially life-threatening condition, characterized by severe metabolic, electrolyte and acid-base disturbances. Among the causes of urethral obstruction, idiopathic cystitis is the most frequent in several studies. Other causes include urolithiasis, urethral plugs and urinary tract infection. In many cases, cats are critically ill and death may occur due to metabolic alterations, such as advanced uremic status and hyperkalemia. The main electrolyte and acid-base balance disorders reported are hyperkalemia, metabolic acidosis, hyponatremia and ionized hypocalcemia. Although urethral obstruction is a very common condition, there are few studies characterizing the population affected by the disease in Brazil. Characteristics related to management, diet and owner’s profile can influence the manifestation of the disease. The aim of the present study was to evaluate the association of clinical, haematological, biochemical, urinary, hydroelectrolyte and acid-base parameters in male cats with urethral obstruction. In addition, the objective was to determine the causes of urethral obstruction in male cats admitted to the Veterinary Teaching Hospital of Federal University of Rio Grande do Sul. Twenty-eight cats diagnosed with urethral obstruction were included in the study between December 2015 and December 2016. Data regarding medical history and physical examination were obtained. Blood and urine were collected, and imaging tests were performed (abdominal radiography and ultrasonography). Complete blood count, serum chemistry, blood pH, gas and electrolyte, urinalysis and urine culture were performed. All patients were treated accordingly to a previous established protocol. The most common cause of urethral obstruction in this study was idiopathic cystitis, which occurred in more than 60% of cases, followed by urethral plugs and urinary tract infection. No diagnosis of urolithiasis was achieved which could be explained by factors like age, environment and life style of cats. Most of obstructed cats presented with multiple systemic clinical signs, as well as, metabolic, electrolyte and acid-base alterations. The main disorders found were azotemia, hyperlactatemia, metabolic acidosis, hyperkalemia and ionized hypocalcemia. Hypothermia, depressed mental status, bradycardia and dehydration were the clinical parameters with the greatest amount of associations with the metabolic alterations and can be considered as good predictors of metabolic disorders. On the other hand, lactate was not considered a good predictor of clinical and laboratory abnormalities in this study.
250

Caracterização de Escherichia coli uropatogênicas isoladas de crianças com infecção urinária. / Characterization of uropathogenic Escherichia coli isolated from children with urinary infection.

Silva Junior, Silvio Marciano da 22 May 2012 (has links)
Infecção do Trato Urinário (ITU) é o segundo tipo de infecção bacteriana mais comum em crianças. Nesse estudo amostras de urina de 6012 pacientes pediátricos foram analisadas, a prevalência de ITU foi determinada, os uropatógenos foram identificados e o perfil antimicrobiano dos mesmos foi determinado. Os resultados mostraram que a prevalência de ITU varia de acordo com o sexo e a idade do paciente. Bactérias Gram-negativas foram responsáveis por 89 % de todos os casos de ITU e Escherichia coli foi a espécie mais prevalente. Os uropatógenos foram resistentes a ampicilina 63 %, a nitrofurantoina 37 % e ao trimethoprim-sulfamethoxazole 28 %. Todavia, 99 % deles foram sensíveis a cefalexina e 96 % ao cloranfenicol. Resultados obtidos com a caracterização de 90 isolados de E. coli, mostraram que todas as amostras foram positivas para os marcadores fimA e fimH, 53 % para pap, 32 % para sfa, 10 % para o marcador genético da toxina pic e 29 % foram capazes de produzir hemolisina-a. Esses isolados se distribuíram entre os grupos filogenéticos da seguinte maneira: B2 42 %, D 25 %, A 21 % e B1 11 %. Dessas amostras 19 % não foram tipáveis (ONT), 15,56 % pertenceram ao sorogrupo O2 e 12,22 % aos sorogrupos O6 e OR. A maioria dos isolados de E. coli aderiu às células epiteliais, poliestireno e PVC. / Urinary Tract Infection (UTI) is the second most common type of bacterial infection in children. In this study, 6012 urine samples from pediatric patients were analyzed, the prevalence of UTI was determined, the uropathogens were identified and their antimicrobial profile was determined. The results have shown that the prevalence of UTI varies according to the sex and age of the patient. Gram negative bacteria were responsible for 89 % of all cases of UTI and E. coli was the most prevalent species. The uropathogens were resistant to: ampicillin 63 %, nitrofurantoin 37 % and trimethoprim-sulfamethoxazole 28 %. However, 99 % of them were sensitive to cephalexin and 96 % to chloramphenicol. Results obtained with the characterization of 90 isolates of E. coli showed that all of them were positive for fimA and fimH, 53 % were positive for pap, 32 % were positive for sfa, 10 % were positive for the genetic marker of pic and 29 % were able to produce hemolysin-a. These isolates were distributed between the phylogenetic groups as follows: B2 42 %, D 25 %, A 21 % and B1 11 %. Nineteen percent of these samples were untypeable (ONT), 15.56 % belonged to O2 serogroup and 12,22 % belonged to the O6 and OR serogroups. Most E. coli isolates were able to adhere to epithelial cells, polystyrene and PVC.

Page generated in 0.1005 seconds