• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 223
  • 126
  • 38
  • 23
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 413
  • 182
  • 171
  • 171
  • 135
  • 132
  • 131
  • 131
  • 131
  • 131
  • 114
  • 103
  • 83
  • 78
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Laser de baixa intensidade na viabilidade do retalho musculofasciocutâneo transverso do músculo reto do abdome em ratos / Low level laser therapy in viability of transverse rectus abdominis musculocutaneous flap in rats

Pinfildi, Carlos Eduardo [UNIFESP] January 2008 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:47:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2008 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Introdução: A terapia a laser de baixa intensidade tem sido utilizada com o objetivo de aumentar a perfusão vascular de retalhos cutâneos e musculofasciocutâneos. Objetivo: Avaliar o efeito da terapia a laser de baixa intensidade na viabilidade do retalho musculofasciocutâneo transverso do reto do abdome em ratos. Método: Foram utilizados 84 ratos Wistar-EPM1 que foram randomicamente distribuídos em 7 grupos com 12 animais cada. O Grupo 1 (simulação), grupo 2 (3J/cm2 com 1 ponto), grupo 3 (3J/cm2 24 pontos), grupo 4 (72J/cm2 1 ponto), grupo 5 (6J/cm2 1 ponto), grupo 6 (6J/cm2 24 pontos) e grupo 7 (144J/cm2 1 ponto). Todos os grupos experimentais foram submetidos a terapia a laser imediatamente após a realização do TRAM e nos outros dois dias subseqüentes. A porcentagem da área de necrose foi calculada no quarto dia pós-operatório por meio do gabarito de papel. Duas amostras foram coletadas por um punch para realizar as avaliações de mastócitos, vasos sanguíneos (1A4) e VEGF. Resultados: Foram encontradas diferenças significantes entre as porcentagens de necrose de todos os grupos, com os valores mais elevados para o grupo 1 comparado aos grupos experimentais. Entre os grupos 3 à 7 não foram encontradas diferenças significantes com p<0,292. Para as avaliações de mastócitos e VEGF os grupos 5 e 7 mostraram um aumento significante quando comparado aos outros grupos. Para avaliação de vasos sanguíneos (1A4) houve um aumento significante para os grupos 3 e 5 quando comparado aos outros grupos. Conclusão: A terapia a laser de baixa intensidade nas fluências de 6 e 144J/cm2 foi eficaz no aumento da viabilidade do retalho musculofasciocutâneo transverso do reto do abdome em ratos. / Introduction: The LLLT has been used with the aim to improve the perfusion vascular of the skin and musculocutaneous flaps. Objective: To assess the effect of low intensity laser therapy on the transverse rectus abdominis musculocutaneous flap (TRAM) viability. Methods: Were used 84 Wistar rats that random divided in 7 groups with 12 rats in each one. The Group 1 (sham laser), group 2 received 3J/cm2 with 1 point, group 3 (3J/cm2 24 points), group 4 (72J/cm2 1point), group 5 (6J/cm2 1point), group 6 (6J/cm2 24 points) and group 7 (144J/cm2 1 point). All experimental groups were undergoing to LLLT immediately after the TRAM operation, and at the next two subsequent days, and so, animals underwent 3 days with applications. The percentage of skin flap necrosis area was calculated on the fourth postoperative day through the paper template method and 2 samples of skin were collected by a 1 cm2 punch in order to perform mat cells evaluation, blood vessels with 1A4 and VEGF evaluations. Results: Were found statistically significant differences among necrosis percentage, and higher values were seen in Group 1, over all other values. Among Groups 3 to 7 statistically significant differences were not found, with p<0.292. To mast cells and VEGF evaluation the group 5 and 7 showed a significant increase when compared to another groups. The 1A4 evaluations showed that the groups 3 and 5 had a increase when compared to another groups. Conclusion: Low level laser therapy on the fluences 6 and 144J/cm2 was efficient to increase transverse rectus abdominis musculocutaneous flap (TRAM) viability in rats. / BV UNIFESP: Teses e dissertações
62

Impacto dos stents e do sirolimus por via oral na vasomotricidade coronariana dependente e independente do endotélio / Impact of stenting and oral sirolimus on endothelium dependent and independent coronary vasomotion

Fernandes, Rósley Weber Alvarenga [UNIFESP] 30 May 2012 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-30. Added 1 bitstream(s) on 2015-08-11T03:26:18Z : No. of bitstreams: 1 Publico-13256.pdf: 2482735 bytes, checksum: eaf78b153b33731b3ff4250c42b843ae (MD5) / Introdução: não há consenso na literatura a respeito do impacto que angioplastia com implante de stents teria sobre a função endotelial vasomotriz. Inúmeros trabalhos têm mostrado piora da função endotelial após o implante de stents farmacológicos quando comparados aos stents convencionais. Objetivos: o principal objetivo deste trabalho foi avaliar o impacto dos stents convencionais e do Sirolimus, administrado por via oral, sobre a função endotelial vasomotriz. Material e métodos: foram selecionados pacientes em três grupos: grupo 1 - stent convencional com alta dose de Sirolimus (15 mg de ataque seguidos de 6 mg diariamente por 4 semanas); grupo 2 - stents convencionais com baixa dose de Sirolimus (6 mg de dose de ataque seguidos de 2 mg diariamente por 4 semanas) e grupo 3 - stent convencional sem Sirolimus. Modificações na vasomotricidade foram avaliadas com uso de infusão de acetilcolina intracoronariana em doses crescentes. A função vasomotriz independente do endotélio foi avaliada com uso de nitroglicerina. O segmento alvo de análise foram os 15 mm distais à borda do stent. Este segmento também foi avaliado com ultrassonografia intracoronariana. Resultados: os três grupos apresentavam características clínicas e angiográficas semelhantes. A porcentagem de variação do diâmetro foi semelhante em todos os três grupos nos dois momentos da avaliação (4 horas após implante do stent e aos 8 meses de acompanhamento) (p=0,469). Quatro horas após implante dos stents o segmento alvo apresentou disfunção endotelial leve a moderada caracterizada por vasoconstrição em média de -3% que se manteve aos oito meses e foi semelhante entre os grupos. Não houve correlação do volume de placa pela ultrassonografia com o grau de disfunção endotelial nos dois momentos da avaliação. A função vasomotriz independente do endotélio encontrava-se preservada nos dois momentos da avaliação nos três grupos. Conclusão: a disfunção endotelial foi semelhante entre os grupos nos dois momentos da avaliação e não sofreu alteração com implante dos stents e nem com o uso do Sirolimus oral por 4 semanas. Não houve correlação do volume de placa com disfunção endotelial. / Rationale: There is no consensus regarding the impact of stenting on long-term endothelial function. There have been reports of increased endothelial dysfunction with Sirolimus-eluting stents as compared to bare metal stenting (SC). Objectives: This study aims to assess the impact of SC and the effect of oral Sirolimus on endothelial function. Methods: Forty-five patients were randomized into three groups: SC + high-dose oral Sirolimus (initial dose of 15 mg, followed by 6 mg/day during four weeks); SC + lowdose Sirolimus (6 mg followed by 2 mg daily during four weeks); and SC without Sirolimus. Changes in vasoconstriction or vasodilation in a 15 mm segment starting at the distal stent end in response to acetylcholine and nitroglycerin were assessed by quantitative angiography. Results: The groups had similar angiographic characteristics. The percent variation in diameter in response to acetylcholine was similar in all groups at the two time points (p = 0.469). Four hours after stenting, the target segment presented an endothelial dysfunction that was maintained after eight months in all groups. In all groups, endothelium-independent vasomotion in response to nitroglycerin was similar at four hours and eight months, with increased target segment diameter after nitroglycerin infusion (p = 0.001). Conclusions: The endothelial dysfunction was similarly present at the 15 mm segment distal to the treated segment, at 4 hours and 8 months after stenting. Sirolimus administered orally during 4 weeks to prevent restenosis did not affect the status of endothelium-dependent and independent vasomotion. / TEDE / BV UNIFESP: Teses e dissertações
63

Avaliação de estanqueidade em vasos de pressão de pequeno porte

Marció, Bruno Silva January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:31:06Z (GMT). No. of bitstreams: 1 332286.pdf: 7274119 bytes, checksum: 1977fff4a302fb340880d76641e81057 (MD5) Previous issue date: 2014 / Na fabricação de vasos de pressão, ensaios não destrutivos são amplamente adotados para garantir a integridade e confiabilidade dos bens produzidos. No caso específico de compressores herméticos para refrigeração, os respectivos ensaios são principalmente aplicados visando assegurar característica essencial do produto, a estanqueidade. Pesquisas realizadas mostraram que métodos para avaliação de estanqueidade atualmente utilizados por fabricantes de compressores herméticos apresentam um desempenho aquém às expectativas, em consequência da baixa eficácia ou do elevado custo para empregá-los. Em vista disso, o presente trabalho apresenta o desenvolvimento de um conceito de sistema de avaliação de estanqueidade para compressores herméticos capaz de ser implantado em linhas de produção. Como parte do trabalho, foi realizado um levantamento bibliográfico, a partir da literatura científica e normas da área, com o objetivo de selecionar um método de ensaio não destrutivo adequado para avaliar estanqueidade em vasos de pressão, particularmente compressores herméticos. Com base nos conceitos do método escolhido, desenvolveu-se um sistema de medição da vibração da carcaça de compressores, provocada pela presença de vazamentos no objeto avaliado. A partir do sistema de avaliação de estanqueidade concebido, ensaios foram realizados para determinar seu desempenho tanto em laboratório quanto em fábrica. O respectivo sistema alcançou um excelente desempenho em laboratório no que se refere à identificação de compressores com vazamento. Porém, tal comportamento não se reproduziu no chão-de-fábrica devido, principalmente, às condições ambientais do local correspondente. Com o intuito de isolar o objeto avaliado do meio externo, uma cabine acústica foi concebida, e ensaios preliminares em laboratório - simulando o ambiente fabril - evidenciaram resultados extremamente promissores. Desse modo, acredita-se que o sistema de avaliação de estanqueidade desenvolvido se torne uma alternativa viável para implantação em linhas de produção.<br> / Abstract: Nondestructive tests are widely used for the assurance of the integrity and reliability of pressure vessels. In relation to hermetic refrigeration compressors, these tests are mainly used to ensure the leak tightness, which is an essential feature of the product. However, researches demonstrated that current leak tightness evaluation methods used by hermetic compressors manufacturers show poor performance, as a result of the low effectiveness and high cost. Thus, this study presents the development of a concept of a leak tightness evaluation system to be used in production lines. The literature was reviewed in order to select a nondestructive testing method suitable for the evaluation of leak tightness in pressure vessels, especially hermetic compressors. It was developed a measurement system able to evaluate the vibration of compressor shell caused by the presence of leaks. Tests were conducted to evaluate its performance in laboratory and in the production line environment. The system achieved excellent performance related to leak detection in laboratory. However, the same performance was not achieved in the production line, mainly due to local environment conditions. An acoustic enclosure was developed to isolate the object under test from external environment. Preliminary tests, performed in laboratory to simulate the factory environment, showed promising results. Thus, it is believed that the developed leak tightness evaluation system might be a suitable alternative to be used in production line.
64

Desenvolvimento de um reator biológico tecidual muscular a partir de vasos de celulose bacteriana

Colla, Guilherme January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:59:20Z (GMT). No. of bitstreams: 1 328682.pdf: 1289481 bytes, checksum: d3c73b57b619fdfc6698fa38bc425b09 (MD5) Previous issue date: 2014 / Doenças cardiovasculares são uma das principais causas de mortalidade em muitas partes do mundo, com a aterosclerose figurando como principal causa de oclusão coronariana, acidente vascular cerebral e aneurisma da aorta. A veia safena é a prótese vascular mais comumente usada para enxertos vasculares de pequeno calibre (< 6 mm). No entanto, 10% -40% dos pacientes não têm uma veia safena adequada para substituição de prótese devido à incompatibilidade de tamanho ou doença venosa. Abordagens de engenharia de tecidos estão sendo usadas para desenvolver métodos paliativos para essas patologias, como a construção de vasos sanguíneos artificiais. Este trabalho teve como objetivo a biossíntese de vasos artificiais a partir de celulose bacteriana (CB) produzida por Gluconacetobacter hansenii. Os vasos obtidos exibiram propriedades mecânicas comparáveis às dos vasos nativos e sua análise morfológica mostrou a presença de fases ligadas entre si, uma superfície densa e outra porosa, imitando a túnica íntima e média dos vasos nativos, respectivamente. A cultura in vitro das células musculares lisas de aorta humana no interior dos vasos de CB demonstrou a sua capacidade de suportar a colonização celular, tendo as células permanecido viáveis após 14 dias de cultura e apresentando uma morfologia alongada. Os vasos colonizados por sete dias seguiram para um reator de fluxo pulsante, onde permaneceram por mais sete dias em condição dinâmica. O vaso de celulose tecidual muscular apresentou a formação de uma monocamada confluente e direcionada paralelamente à direção do fluxo contínuo. Em condições de cultura dinâmica as células apresentaram maior viabilidade e capacidade de proliferação do que no controle estático, indicando que o ambiente celular propiciado pelo reator de perfusão mimetizam aqueles encontrados no sistema vascular natural. Estes vasos de CB constituem uma plataforma para aplicações como biorreator tecidual, permitindo ensaios com células e outros agentes terapêuticos, através de interações com a monocamada de células confluentes que responde à estimulação dinâmica de fluxo pulsante.<br> / Abstract : Cardiovascular diseases are one of the main causes of mortality in many parts of the world, with atherosclerosis figuring as the principal cause of coronary occlusion, stroke and aortic aneurysm. Saphenous vein is the most commonly used vascular prosthesis for small-caliber (< 6 mm) vascular grafts, however, 10%?40% of patients do not have a saphenous vein suitable for prosthetic replacement due to size mismatch or venous disease. Tissue engineering approaches are being used to develop palliative methods for these pathologies such as the construction of artificial blood vessels. Here we describe the biosynthesis of artificial blood vessels using Gluconacetobacter hasenii?s bacterial cellulose (BC) as scaffolding. The vessels obtained exhibited morphological and mechanical properties similar to native vessels and their morphology showed the presence of a dense and a porous phase, connected as a basis to mimic the intimal and medial layers of a blood vessel, respectively. In vitro cultures of human aortic smooth cells HASMCs in the presence of cellulose tubular scaffolds demonstrated their ability to support cell colonization, with cells remaining viable after 14 days of culture and showing an elongated morphology. Vessels colonized for seven days were placed in a pulsed flow reactor, where they remained for another seven days in dynamic condition. The cellulose muscle tissue vessel showed the formation of a confluent monolayer oriented parallel to direction in the continuous flow. In the interior of the vessels, cells in dynamic culture condition showed greater proliferation and cell viability compared to the static control. These BC vessels have proved to be a promising platform for the development of an in vivo-like bioreactor, allowing cell and drug assays on the confluent cell monolayer which responds to the dynamic stimulation of pulsatile flow.
65

Filmes de colágeno - polissacarídeo sulfatado como matrizes com propriedades antitrombogênicas: preparação e caracterização. / Collagen - sulfated polysaccharide films with antithrombogenic properties: preparation and characterization.

Macedo, Ana Angélica Mathias January 2006 (has links)
MACEDO, A. A. M. Filmes de colágeno - polissacarídeo sulfatado como matrizes com propriedades antitrombogênicas: preparação e caracterização. 2006. 77 f. Dissertação (Mestrado em Bioquímica) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2006. / Submitted by Francisco Lacerda (lacerda@ufc.br) on 2014-10-06T18:24:22Z No. of bitstreams: 1 2006_dis_aammacedo.pdf: 1291383 bytes, checksum: 82d27442aec13166192157ba1d4a7a47 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2015-01-19T17:43:50Z (GMT) No. of bitstreams: 1 2006_dis_aammacedo.pdf: 1291383 bytes, checksum: 82d27442aec13166192157ba1d4a7a47 (MD5) / Made available in DSpace on 2015-01-19T17:43:50Z (GMT). No. of bitstreams: 1 2006_dis_aammacedo.pdf: 1291383 bytes, checksum: 82d27442aec13166192157ba1d4a7a47 (MD5) Previous issue date: 2006 / This work reports the preparation and characterization of collagen-sulfated polysaccharide films and applications in coating of cardiovascular prostheses. The films were prepared by adding the sulfated polysaccharide solution on soluble collagen (0, 5, 10, 20 and 25 %). The blends of collagen-sulfated polysaccharide were casted in acrylic molds, and dried at low temperature. The physico-chemical properties of collagen-sulfated polysaccharide films, were studied using infrared spectroscopy that showed absorptions typical of collagen and sulphated polysaccharide; the thermal analysis (DSC) showed that the structural integrity of collagen was unmodified during the extraction process and the polysaccharide present in the samples did not decrease the thermal stability of the collagen, which was higher for the concentrations of 20 %. In the thermal analysis (DTG), the addition of the polysaccharide caused a small decrease of the stability of thermal degradation and when was adding 5 % of the sulfated polysaccharide to the collagen, a reduction in its stability occurs, however, in the concentrations of 10, 20 and 25 %, the stability of thermal degradation of the film increased. In the impedance spectroscopy, the results are associated possibly, to the interactions between the macromolecules. The blood compatibility was analyzed by platelet adhesion and the results showed that the films possess hemocompatibility and antitrombogenic properties. / Este trabalho aborda sobre o preparo e a caracterização de filmes de colágeno-polissacarídeo sulfatado e sua aplicação para revestimento de próteses vasculares. Os filmes foram obtidos a partir da mistura de solução de colágeno e polissacarídeo sulfatado, nas concentrações 0, 5, 10, 20 e 25 % do polissacarídeo. As soluções de colágeno-polissacarídeo sulfatado foram formatadas em moldes de acrílico em condições de baixa umidade e temperatura. A caracterização físico-química dos filmes de colágeno-polissacarídeo sulfatado foi estudada por espectrometria no infravermelho que mostraram bandas típicas do colágeno e bandas típicas do polissacarídeo sulfatado; a análise térmica por DSC mostra que a integridade estrutural do colágeno foi preservada no processo de extração e que a adição do polissacarídeo nas amostras não diminuiu a estabilidade térmica do colágeno tendo sido maior na concentração de 20 %. Na análise térmica por DTG, a adição do polissacarídeo causa um pequeno decréscimo da estabilidade de degradação térmica e ao adicionarmos 5 % do polissacarídeo sulfatado ao colágeno, ocorre uma redução em sua estabilidade, porém, a partir daí, nas concentrações 10, 20 e 25 %, a estabilidade de degradação térmica do filme vai aumentando. Na espectroscopia de impedância, os resultados estão associados, possivelmente, a interações entre as macromoléculas. A compatibilidade sangüínea foi analisada por adesão de plaquetas e os resultados mostraram que os filmes possuem hemocompatibilidade e propriedades antitrombogênicas.
66

Custo efetividade de tecnologias contemporâneas no manejo da doença arterial coronariana : stents farmacológicos e cateter de medida de fluxo (FFR)

Stella, Steffan Frosi January 2014 (has links)
Resumo não disponível
67

Desenvolvimento de transdutor de pressão aplicável em câmaras de compressão de pequeno volume

Pierri, Lidiani Cristina January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnologico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2012. / Made available in DSpace on 2013-07-16T04:29:41Z (GMT). No. of bitstreams: 1 317266.pdf: 2141142 bytes, checksum: 8727df5e34df1eddced55e776d20bcd6 (MD5) / Compressores de refrigeração cada vez menores vêm sendo desenvolvidos e fabricados. Em função disso, as câmaras de compressão também diminuem de tamanho. Para garantir a qualidade do projeto e da fabricação de compressores, ensaios para a verificação de desempenho são realizados. Um dos mais importantes é o levantamento do diagrama pressão-volume, com o qual se pode determinar a eficiência do compressor. Os transdutores de pressão atualmente empregados para determinar a grandeza pressão do interior da câmara do compressor provocam o aumento do que é chamado de volume morto, alterando o volume final da câmara e, consequentemente, introduzindo erro no processo. Sendo assim, quanto menor o volume da câmara, menos adequados são os transdutores atuais. Um trabalho anterior a este analisou possíveis tecnologias e procedimentos de construção de transdutores adequados para tal finalidade e apontou como mais promissora a utilização de extensômetros resistivos metálicos. Este trabalho avança nessa linha, desenvolvendo um transdutor e fazendo uma avaliação preliminar do seu comportamento metrológico. Alternativas para melhorias de vedação são apresentadas, assim como um estudo, via elementos finitos, da interferência da deformação da placa-válvula no transdutor. Além disso, diversos ensaios foram realizados com protótipos e estes apresentaram baixo erro de linearidade e boa repetibilidade. Análises em diferentes temperaturas indicaram comportamentos diferentes em ciclos de aquecimento e resfriamento do transdutor, mostrando um grande desafio ainda a ser vencido. Passos no sentido da solução foram dados neste trabalho e propostas de ações futuras são apresentadas.<br> / Abstract : Market and application requirements are inducing refrigeration compressors industries to develop and manufacture compressors with reduced dimensions. As a consequence, the compression chambers are also reducing in volume. For ensuring quality to the compressors design and production, tests for performance verifications must be carried out. One of the most important tests is the evaluation of the pressure-volume diagram that is directly related to the compressor efficiency assessment. A drawback of the transducers currently used for measuring the pressure in compressor chambers is the dead volume associated to their assembly. This dead volume changes the chamber volume and affects the pressure during the compression cycle. In a previous dissertation were examined suitable technologies and procedures for constructing pressure transducers. It was pointed out that metallic resistive strain gages is the most promising technology. The current dissertation presents the use of this technology for developing a transducer and preliminary assessments of its metrological behavior. Moreover, alternative techniques are presented for sealing improvement, as well as finite element simulations for evaluating the influence of the transducer seat deformation. Furthermore, several tests were performed and low linearity error and good repeatability could be observed. Analysis at different temperatures indicated unlike behaviors at heating and cooling cycles of the transducer, these results shown that there still is a great challenge to be overcome. Steps towards the solution were given in this dissertation and proposals for future actions are presented.
68

Análise de efeitos de teste hidrostático em vaso de pressão

Pereira Filho, Jorge dos Santos January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Mecânica / Made available in DSpace on 2012-10-21T11:47:41Z (GMT). No. of bitstreams: 1 214310.pdf: 1178570 bytes, checksum: 357336f85a436ce2f39669fcf588e908 (MD5) / Objetiva-se analisar a propagação subcrítica e crítica de descontinuidades durante a execução de testes hidrostáticos em vasos de pressão. Considera-se principalmente o teste hidrostático periódico, originado de requisitos legais, e pressões de teste da ordem de 1,5 vezes a pressão máxima admissível. Duas situações distintas foram consideradas, para permitir uma maior abrangência de análise: a primeira, representada por um vaso de pressão fabricado em aço carbono, não sujeito a mecanismos de danos durante a sua vida operacional, e contendo um defeito de fabricação do tipo falta de fusão em um bocal; a segunda é representada por uma coluna de processo fabricada em aço inoxidável austenítico, que foi submetida a corrosão-sob-tensão sob isolamento, e apresentou trincas ramificadas na superfície metálica. A análise se desenvolveu pela verificação da estabilidade e cálculo dos parâmetros relacionados à integral J. Para tanto, utilizou-se de documentos como a BS-7910 e API 579, além de formulações para cálculo de J. As tensões foram calculadas pelo método dos elementos finitos, resultando na linearização das mesmas na seção de interesse. Também foi avaliada a propagação por fadiga e corrosão-sob-tensão combinadas, e também pelo critério "leak before break". Verificou-se que no caso do vaso de aço carbono não houve qualquer propagação, enquanto que no caso da coluna de aço inoxidável houve propagações para as maiores profundidades de trincas, durante o teste hidrostático. As conclusões resultantes deste trabalho estão relacionadas a haver ou não alguma alteração durante o teste hidrostático periódico em relação ao teste hidrostático original, realizado após a fabricação. O fluxograma desenvolvido caracteriza os aspectos determinantes de uma possível propagação, devendo ser utilizado previamente à realização de um teste hidrostático periódico.
69

Análise de efeitos de teste hidrostático em vaso de pressão

Pereira Filho, Jorge dos Santos January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Mecânica / Made available in DSpace on 2012-10-22T05:52:45Z (GMT). No. of bitstreams: 1 250100.pdf: 1178570 bytes, checksum: 357336f85a436ce2f39669fcf588e908 (MD5) / Objetiva-se analisar a propagação subcrítica e crítica de descontinuidades durante a execução de testes hidrostáticos em vasos de pressão. Considera-se principalmente o teste hidrostático periódico, originado de requisitos legais, e pressões de teste da ordem de 1,5 vezes a pressão máxima admissível. Duas situações distintas foram consideradas, para permitir uma maior abrangência de análise: a primeira, representada por um vaso de pressão fabricado em aço carbono, não sujeito a mecanismos de danos durante a sua vida operacional, e contendo um defeito de fabricação do tipo falta de fusão em um bocal; a segunda é representada por uma coluna de processo fabricada em aço inoxidável austenítico, que foi submetida a corrosão-sob-tensão sob isolamento, e apresentou trincas ramificadas na superfície metálica. A análise se desenvolveu pela verificação da estabilidade e cálculo dos parâmetros relacionados à integral J. Para tanto, utilizou-se de documentos como a BS-7910 e API 579, além de formulações para cálculo de J. As tensões foram calculadas pelo método dos elementos finitos, resultando na linearização das mesmas na seção de interesse. Também foi avaliada a propagação por fadiga e corrosão-sob-tensão combinadas, e também pelo critério "leak before break". Verificou-se que no caso do vaso de aço carbono não houve qualquer propagação, enquanto que no caso da coluna de aço inoxidável houve propagações para as maiores profundidades de trincas, durante o teste hidrostático. As conclusões resultantes deste trabalho estão relacionadas a haver ou não alguma alteração durante o teste hidrostático periódico em relação ao teste hidrostático original, realizado após a fabricação. O fluxograma desenvolvido caracteriza os aspectos determinantes de uma possível propagação, devendo ser utilizado previamente à realização de um teste hidrostático periódico.
70

Efeitos do LRP6 e Frizzled6 na diferenciação endotelial de DPSC

Silva, Gleyce Oliveira [UNESP] 31 July 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:54:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-31. Added 1 bitstream(s) on 2016-04-01T18:00:34Z : No. of bitstreams: 1 000860768.pdf: 1686526 bytes, checksum: 979e2944f4a6b89a46fd9bb6b0302204 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar a função da via de sinalização Wnt/β- catenina através dos receptores LRP6 e Frizzled6 na diferenciação de células-tronco de polpa dental de dentes permanentes (DPSC) em células endoteliais. DPSC foram transduzidas com marcadores eGFP e vetores lentivirais shRNA (LRP6, Frizzled6 ou vetor vazio - controle) para os experimentos. Os testes in vitro avaliaram a expressão de GSK3-β e β- catenina por western blot na presença de rhWnt1 e rhVEGF165 e de VEGF e CXCL-8 (IL-8) por ELISA. A expressão de marcadores endoteliais (western blot e PCR) e formação de túbulos capilares foram analisados após a diferenciação endotelial das DPSCs. In vivo, fatias dentárias/matrizes condutivas semeadas com DPSCs-shRNA foram implantadas em subcutâneo de dorso de camundongos imunodeprimidos por 28 dias e o número de vasos sanguíneos foi determinado por imunohistoquímica para eGFP e coloração por HE. β-catenina ativa foi mais expressa em shRNA-LRP6 e shRNA-Frizzled6 que nas células controle, e sua expressão aumentou com a suplementação com rhVEGF165 e rhWnt1. A expressão de GSK3-β fosforilado foi menor, porém também aumenta ou permanece estável com rhVEGF165 ou rhWnt1. Quanto à expressão de VEGF, em shRNA-Frizzled6 foi maior que nas células controle e em shRNA-LRP6 (p<0,05), enquanto que a expressão de IL8 foi menor em shRNA-LRP6, diferindo estatisticamente das outras células. A expressão dos marcadores endoteliais CD31 e VEGFR2 diminuiu nas células shRNA-LRP6, enquanto que em shRNAFrizzled6 a expressão de VEGFR2 foi aumentada. A formação de túbulos capilares de shRNA-Frizzled6 e shRNA-LRP6 foi menor quando comparado ao controle, porém shRNA-Frizzled6 obteve uma tendência de aumento na proliferação de capilares em 144h. In vivo, DPSC-shRNALRP6 apresentou menor número de capilares formados quando comparados com as outras duas... / The aim of this study was to evaluate the function of Wnt/β-catenin signaling through LRP-6 and Frizzled-6 receptors in the differentiation of dental pulp stem cells from permanent teeth (DPSC) into endothelial cells. DPSC were transduced with EGFP-tagged lentiviral shRNA vectors (LRP6, Frizzled6 or empty vector - control) for experiments. In vitro assay evaluated GSK3-β and β-catenin expression by western blot in rhWnt1 and rhVEGF165 presence, and VEGF and CXCL-8 (IL-8) expression by ELISA. Endothelial markers expression (western blot and PCR) and tube formation were analyzed after endothelial differentiation of DPSCs. In vivo, tooth slices/scaffolds seeded with transduced DPSCs were implanted subcutaneously in back of immunodefficient mice and blood vessels were counted per immunohistochemistry for eGFP and HE staining. Active β- catenin was more expressed in shRNA-LRP6 and shRNA-Frizzled6 than in control cells, and increased with rhVEGF165 and rhWnt1 supplementation. Phosphorylated GSK3-β expression was lower, however also increased or maintained with rhVEGF165 or rhWnt1. VEGF expression was higher in shRNA-Frizzled6 than in control and shRNA-LRP6 (p<0,05), IL8 expression was lower in shRNA-LRP6, with statistically difference of the others cells. Endothelial markers CD31 and VEGFR2 expression decreased in shRNA-LRP6, but VEGFR2 expression increased in shRNAFrizzled6. shRNA-Frizzled6 and shRNA-LRP6 tube formation was lower when compared to control, however shRNA-Frizzled6 had tendency to increase proliferation in 144h. In vivo, shRNA-LRP6 showed fewer blood vessels formed than other cells (p<0,05). Collectively, the results of this study suggest that Wnt/β-catenin signaling regulates endothelial differentiation of DPSC through LRP6

Page generated in 0.0557 seconds