Spelling suggestions: "subject:"ventilador"" "subject:"ventilación""
1 |
Desenvolvimento de um sistema de ventila??o for?ada para secar o fio m?quina na lamina??o a frio de vergalh?esRocha, F?bio Augusto Costa da 29 May 2012 (has links)
Made available in DSpace on 2015-04-14T13:58:51Z (GMT). No. of bitstreams: 1
439945.pdf: 2035621 bytes, checksum: 74dbb8f5ad2bb0c294b36e4fbd0fa10c (MD5)
Previous issue date: 2012-05-29 / The national steel industry has been modernized. Indeed, its processes seek stability in the production area. The cold rolling of rebars is a process which is evolving: technological advance allows such machines, for example, reach speeds up to 17 m/s. However, high speeds bring the probability of interruptions in production. At Gerdau, the cold rolling mills are common, and one of the main reasons identified by stopping production units throughout Brazil is just a interruption in machinery because of wire rod wet by the rain water. This fact is because the lubricant and has very small particles with the passage of the wire rod wet, expands, and deposited on the cassettes - the equipment responsible for a reduction of the wire rod - locking the bearings of the rolls. The solution adopted for the removal of water from the wire rod was the installation of a system compound of a tube with bearings at the ends two nozzles spaced 120? from e ach other. In theses nozzles are hoses coupled, in turn, are connected to a centrifugal fan. The implementation of this system guaranteed, thus, the stability of the process, even on rainy days. / A siderurgia nacional vem se modernizando. Logo, seus processos buscam a estabilidade na ?rea de produ??o. A lamina??o a frio de vergalh?es ? um processo que vem evoluindo: o avan?o tecnol?gico permite a tais m?quinas, por exemplo, alcan?ar velocidades de at? 17 m/s. Entretanto, altas velocidades trazem consigo a probabilidade de interrup??es na produ??o. Na Gerdau, os laminadores a frio s?o comuns, e um dos principais motivos de parada identificado pelas unidades de produ??o espalhadas pelo Brasil ? justamente a interrup??o das m?quinas em virtude de fio m?quina molhado pela ?gua da chuva. Tal fato se d? porque o lubrificante possui part?culas muito pequenas e, com a passagem do fio m?quina molhado, se expande, e com o arraste, se aglomera sobre os cassetes equipamentos respons?veis pela redu??o da ?rea do fio m?quina trancando os rolamentos dos rolos laminadores. A solu??o adotada para a retirada da ?gua do fio m?quina foi a instala??o de um sistema composto por um tubo com mancais nas pontas mais dois bicos distanciados 120? um do outro. Nesses bicos est?o acopladas mangueiras que, por sua vez, est?o conectadas a um ventilador centr?fugo. A implanta??o desse sistema garantiu, dessa forma, a estabilidade do processo, mesmo em dias chuvosos.
|
2 |
Estrat?gias de ventila??o natural e sua influ?ncia na renova??o do ar em uma edifica??o hospitalar: anteprojeto de um novo ambulat?rio para o Hospital Universit?rio Onofre LopesClemente, Fabiano Fechine Torres 31 July 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-03-12T20:24:38Z
No. of bitstreams: 1
FabianoFechineTorresClemente_DISSERT.pdf: 35056002 bytes, checksum: 41ba19bd8f6d578f57a68b5233e5a621 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-03-16T20:05:40Z (GMT) No. of bitstreams: 1
FabianoFechineTorresClemente_DISSERT.pdf: 35056002 bytes, checksum: 41ba19bd8f6d578f57a68b5233e5a621 (MD5) / Made available in DSpace on 2018-03-16T20:05:40Z (GMT). No. of bitstreams: 1
FabianoFechineTorresClemente_DISSERT.pdf: 35056002 bytes, checksum: 41ba19bd8f6d578f57a68b5233e5a621 (MD5)
Previous issue date: 2017-07-31 / Alguns s?tios na cidade de Natal/RN possuem agrad?veis condi??es de ventila??o
natural, no entanto, as edifica??es constru?das dependem excessivamente de
sistemas de ar-condicionado para renova??o do ar, muitas vezes fruto de um
planejamento inadequado que n?o prioriza aspectos do conforto ambiental. Sendo
assim, o trabalho a seguir trata-se do anteprojeto arquitet?nico de um novo
ambulat?rio para o Hospital Universit?rio Onofre Lopes com ?nfase na aplica??o de
estrat?gias passivas de ventila??o natural com objetivo de promover um maior n?mero
de trocas de ar no interior dos ambientes. O pr?dio possui uma ?rea constru?da de
31.998,97m?, distribu?dos ao longo de 10 pavimentos, sendo um t?rreo e mais 06
andares superiores, al?m de tr?s subsolos, a ser edificado na ?rea 01 do Campus
Biom?dico da Sa?de, localizado no Bairro de Petr?polis. A ado??o do partido
arquitet?nico levou em considera??o uma s?rie de condicionantes tais como
topografia do terreno, dire??o e velocidade dos ventos predominantes, sistema
construtivo, al?m daquelas de ordem normativas, com destaque para NBR-15220 e
C?digo de Combate a Inc?ndio. Os procedimentos metodol?gicos adotados
envolveram o c?lculo do fluxo e n?mero de trocas de ar por hora nas salas de espera,
consult?rios e mecanoterapia/termoterapia que foram registrados em mem?rias de
c?lculo, para o qual foi necess?rio o conhecimento das velocidades dos ventos no
interior dos ambientes analisados, de dados obtidos na base de dados do Laborat?rio
de Conforto Ambiental da Universidade Federal do Rio Grande do Norte, al?m da
utiliza??o de refer?ncias bibliogr?ficas sobre o tema do conforto t?rmico. Os
resultados obtidos mostram que as estrat?gias de ventila??o cruzada aplicadas no
projeto, tais como utiliza??o de sheds na cobertura para captar o vento em dire??o a
po?os de ventila??o, aliados a ?trios internos e loca??o de aberturas em pontos
opostos com diferentes coeficientes de press?o, dimensionadas e sombreadas
adequadamente, provocam um aumento no fluxo e n?mero de trocas de ar por hora
no interior dos ambientes quando comparado ? ventila??o unilateral. Dessa forma
permite-se que cada um seja ocupado por uma maior quantidade de pessoas,
requisito esse importante para a funcionalidade do pr?dio, j? que o hospital trata-se
de uma institui??o de ensino. Dessa forma, potencializa-se o uso da ventila??o natural
e cria-se as condi??es para minimizar o consumo de ar condicionado, que contribui
para o planejamento de uma arquitetura com mais efici?ncia energ?tica. / Some sites in the city of Natal / RN have pleasant conditions of natural ventilation,
however, the built buildings rely heavily on air conditioning systems for air renovation,
often the result of inadequate planning that does not prioritize aspects of environmental
comfort. Therefore, the following work deals with the architectural design of a new
outpatient clinic for the University Hospital Onofre Lopes, with emphasis on the
application of passive strategies of natural ventilation with the objective of promoting a
greater number of air changes within the environments. The building has a built area
of 31,998.97m?, distributed over 10 floors, one ground floor and a further six floors, in
addition to three basements, to be built in area 01 of the Biomedical Health Campus,
located in the Petropolis District. The adoption of the architectural party took into
account a series of constraints such as topography of the terrain, direction and speed
of prevailing winds, construction system, besides those of normative order, especially
NBR-15220 and Fire Code. The methodological procedures adopted involved
calculating the flow and number of air changes per hour in the waiting rooms, clinics
and mechanotherapy / thermotherapy that were recorded in calculation memories, for
which it was necessary to know the velocities of the winds inside the environments
analyzed, from data obtained from the Laboratory of Environmental Comfort of the
Federal University of Rio Grande do Norte, in addition to the use of bibliographical
references on the topic of thermal comfort. The results show that the cross ventilation
strategies applied in the design, such as the use of sheds in the roof to capture the
wind towards ventilation wells, allied to internal atria and rent of openings in opposite
points with different pressure coefficients, dimensioned and properly shaded, cause
an increase in the flow and number of air changes per hour inside the environments
when compared to unilateral ventilation. In this way, each one is allowed to be occupied
by a larger number of people, a requirement that is important for the functionality of the
building, since the hospital is a teaching institution. In this way, the use of natural
ventilation is potentiated and conditions are created to minimize the consumption of air
conditioning, which contributes to the planning of a more energy efficient architecture.
|
3 |
Os efeitos do balan?o h?drico positivo em lactentes menores de um ano com bronquiolite viral aguda submetidos ? ventila??o mec?nicaKorb, Cecilia 30 August 2013 (has links)
Made available in DSpace on 2015-04-14T13:33:08Z (GMT). No. of bitstreams: 1
451920.pdf: 503995 bytes, checksum: 18877f49594a02c1abdbc2ab1583ecfb (MD5)
Previous issue date: 2013-08-30 / Objective : to evaluate the effects of positive fluid balance in infants under one year with bronchiolitis undergoing mechanical ventilation. Methodos : retrospective cohort study based on analysis of medical records of infants under one year admitted from April 2008 to September 2011 with bronchiolitis requiring mechanical ventilation in a tertiary Pediatric Intensive Care Unit (PICU) in southern of Brazil. We excluded patients with chronic lung disease, tracheostomy and previous use of mechanical ventilation due to acute pulmonary disease. We calculated the cumulative fluid balance within the first 3 days of the onset of mechanical ventilation. The outcomes assessed were ventilator-free days, length of stay in PICU, ventilator parameters used on the third day. Results : eighty-one patients were included in the study, 49 males (60.5%). The mean cumulative fluid balance on the third day of mechanical ventilation was 139 ? 68 ml/kg, the ventilator-free days was 19.7 ? 5.7 and the length of stay in PICU was 10.4 ? 5 6 days. In multivariate analysis, increasing cumulative fluid balance on the third day of mechanical ventilation was associated with a lower number of ventilatorfree days (β -.03; 95% CI -.05, -.01; p <.001). The increasing cumulative fluid balance on the third day was also associated with higher PEEP and higher FiO2 used on the same day (β .01; 95% CI.006, .019; p <.001 and β .09; 95% CI .053, .136; p <.001 respectively). There was no relationship between cumulative fluid balance and length of stay in PICU (p = .950). Conclusion : cumulative fluid balance on the third day of mechanical ventilation is an independent risk factor for a lower number of ventilator-free days in infants under one year with bronchiolitis. There is also an association between higher cumulative fluid balance on the third day of mechanical ventilation and higher PEEP and higher FiO2 on the same day. / Objetivo : avaliar os efeitos do balan?o h?drico positivo em lactentes menores de um ano com bronquiolite viral aguda submetidos ? ventila??o mec?nica. Material e m?todo : estudo de coorte retrospectivo baseado na an?lise de prontu?rios de lactentes menores de um ano admitidos no per?odo de abril de 2008 a setembro de 2011 por bronquiolite viral aguda e submetidos ? ventila??o mec?nica em uma Unidade de Terapia Intensiva Pedi?trica (UTIP) terci?ria no sul do Brasil. Foram exclu?dos os pacientes com doen?a pulmonar cr?nica, traqueostomizados e com uso pr?vio de ventila??o mec?nica devido ? doen?a pulmonar aguda. Foi calculado o balan?o h?drico cumulativo nos primeiros 3 dias do in?cio da ventila??o mec?nica. Os desfechos avaliados foram: dias livres de ventila??o mec?nica, tempo de interna??o na UTIP e par?metros de ventila??o mec?nica utilizados no terceiro dia. Resultados : oitenta e um pacientes foram inclu?dos no estudo, sendo 49 meninos (60,5%). A m?dia do balan?o h?drico cumulativo no terceiro dia de ventila??o mec?nica foi de 139 ? 68 ml/kg, de dias livres de ventila??o mec?nica foi 19,7 ? 5,7 e do tempo de interna??o na UTIP foi 10,4 ? 5,6 dias. Na an?lise multivari?vel, um maior balan?o h?drico cumulativo no terceiro dia de ventila??o mec?nica apresentou associa??o com um menor n?mero de dias livres de ventila??o mec?nica (β -0,03; IC 95% -0,05 a -0,01; p <0,001). O balan?o h?drico cumulativo no terceiro dia tamb?m apresentou associa??o com a utiliza??o de maior PEEP e FiO2 neste mesmo dia (β 0,01; IC 95% 0,006 a 0,019; p <0,001 e β 0,09; IC 95% 0,053 a 0,136; p <0,001 respectivamente). N?o houve rela??o entre balan?o h?drico cumulativo e tempo de interna??o na UTIP (p=0,950). Conclus?o : o balan?o h?drico cumulativo no terceiro dia de ventila??o mec?nica constitui fator de risco independente para um menor n?mero de dias livres de ventila??o mec?nica em lactentes menores do um ano com bronquiolite viral aguda. Existe, tamb?m, associa??o entre um maior balan?o h?drico cumulativo no terceiro dia de ventila??o mec?nica e a utiliza??o de maior PEEP e maior FiO2 neste mesmo dia.
|
4 |
Redu??o da demanda de energia el?trica utilizando par?metros construtivos visando ao conforto t?rmicoBaltar, Marta Garcia 30 August 2006 (has links)
Made available in DSpace on 2015-04-14T13:56:08Z (GMT). No. of bitstreams: 1
384715.pdf: 1956020 bytes, checksum: 3db73ba49319745144db2d25f7331e16 (MD5)
Previous issue date: 2006-08-30 / Este trabalho tem por objetivo avaliar a influ?ncia de par?metros construtivos na demanda e consumo de energia el?trica para fins de condicionamento t?rmico ambiental. Os par?metros construtivos avaliados englobam tipos de vidros, cores externas das fachadas e revestimento nas paredes internas. As an?lises s?o realizadas atrav?s do programa de simula??o termoenerg?tica EnergyPlus e avaliadas a partir de um m?todo desenvolvido para analisar a efic?cia das alternativas construtivas. As avalia??es s?o realizadas tendo como base a edifica??o do Hospital Bruno Born, localizado em Lajeado, Rio Grande do Sul. A an?lise visa minimizar o consumo de energia el?trica no sistema de ar condicionado e atender todos os requisitos de conforto e assepsia de treze quartos de interna??o do estabelecimento hospitalar, de acordo com os ?ndices de temperatura especificados na NBR-6401. Visando averiguar as condi??es do ambiente t?rmico e o consumo de energia el?trica, s?o avaliados os ?ndices de conforto t?rmico, as temperaturas internas e a pot?ncia necess?ria do ar condicionado de expans?o direta para cada um dos treze quartos de interna??o do hospital, verificando o consumo energ?tico das alternativas utilizadas e a rela??o custo-benef?cio da melhor alternativa. Atrav?s das simula??es constatou-se que com a utiliza??o de materiais eficientes termicamente as trocas t?rmicas do interior com o exterior s?o minimizadas, diminuindo o consumo energ?tico do sistema de ar condicionado.
|
5 |
Interven??es n?o farmacol?gicas para o controle das doen?as pulmonares cr?nicasPires, Bruna Souza Vargas 29 August 2014 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-07-01T21:18:48Z
No. of bitstreams: 1
471590 - Texto Parcial.pdf: 399268 bytes, checksum: 811650fee8352c7477a6f3dfc7117912 (MD5) / Made available in DSpace on 2015-07-01T21:18:48Z (GMT). No. of bitstreams: 1
471590 - Texto Parcial.pdf: 399268 bytes, checksum: 811650fee8352c7477a6f3dfc7117912 (MD5)
Previous issue date: 2014-08-29 / Introduction: Pulmonary rehabilitation has been indicated for lung transplant candidates as a preventive and therapeutic intervention to improve patients? functional capacity and quality of life. Objective: To evaluate the benefits of pulmonary rehabilitation on functional capacity and quality of life of patients in the waiting list or who have already been transplanted. Methodology: The potential eligible studies published until June 2014 were identified through a database search in MEDLINE, EMBASE, LILACS, Cochrane Central Register of Controlled Trials, Pedro, Web of Science, and in reference of the articles. The search was conducted using a combination of the following terms: ?Pulmonary Rehabilitation? AND ?Lung Transplant? OR ?Lung Transplant Candidates?. Trials which the intervention consisted of pre and/or postoperative pulmonary rehabilitation programs were included. Articles that the rehabilitation included only nutritional and/or drug and/or psychosocial interventions; research that did not have pulmonary rehabilitation as the main focus and that were related to other transplanted organs; and even the ones that did not differentiate the results obtained by the transplanted organ were excluded. The main study outcomes were functional capacity and health-related quality of life, survival was shown as a secondary one. Two reviewers independently assessed the articles regarding their eligibility criteria. A third reviewer determined the inclusion of items in situations of disagreement between the other reviewers. The quality criteria of the articles were assessed by the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) instrument and in evidence-based medicine. Results: Seven articles were included in this systematic review, totaling 314 patients with a mean age of 32.5 years. There was an increase on average of 47.6 meters in the 6-minute walk test for preoperative pulmonary rehabilitation programs and 122 meters in the postoperative rehabilitation program. The maximal oxygen consumption (VO2 peak) increased, on average, 0.41 in postoperative pulmonary rehabilitation programs using cycle ergometers. The domains of physical and mental health of the SF-36 questionnaire had significant increases in the preoperative period. There was significant improvement in all domains of the SF-36 with the postoperative pulmonary rehabilitation program. The Chronic Respiratory Questionnaire (CRQ) was mentioned in just one article in the postoperative period which showed improvement in dyspnea with an increase of 0.6 points. Conclusion: Pulmonary rehabilitation is an effective intervention for both pre and post-lung transplantation. The findings suggest significant changes in functional capacity and quality of life of these patients. Methodologically, the studies should provide accurate and valid data for pre and postoperative pulmonary rehabilitation. New clinical trials on the benefits of rehabilitation should be started, keeping the concern with ethics, randomization, homogeneous groups and the logistical challenges of such tests. / Introdu??o: A reabilita??o pulmonar tem sido indicada para os pacientes candidatos a transplante pulmonar como uma interven??o preventiva e terap?utica para a melhora da capacidade funcional e da qualidade de vida. Objetivo: avaliar os benef?cios da reabilita??o pulmonar na capacidade funcional e na qualidade de vida em pacientes em lista de espera ou transplantados pulmonar. Metodologia: Os potenciais estudos eleg?veis publicados at? junho 2014 foram identificados a partir da pesquisa nas bases de dados MEDLINE, EMBASE, LILACS, Cochrane Central Register of Controlled Trials, Pedro, Web of Science e na lista de refer?ncias dos artigos. A pesquisa foi realizada utilizando a combina??o dos seguintes termos: ?Pulmonary Rehabilitation? AND ?Lung Transplant? OR ?Candidates Lung Transplant?. Foram inclu?dos ensaios cl?nicos que a interven??o consistiu em programas de reabilita??o pr? e/ou p?s-transplante pulmonar. Foram exclu?dos os artigos que a reabilita??o incluiu apenas interven??es nutricionais e/ou medicamentosa e/ou psicossociais; pesquisas que n?o trouxessem a reabilita??o pulmonar como enfoque principal e que se relacionaram a outros ?rg?os transplantados, ou ainda que n?o diferenciaram os resultados obtidos por ?rg?o transplantado. Os desfechos principais do estudo foram ? capacidade funcional e a qualidade de vida relacionada ? sa?de sendo a sobrevida o desfecho secund?rio. Dois revisores analisaram independentemente artigos quanto aos crit?rios de elegibilidade. Um terceiro pesquisador definiu a inclus?o dos artigos em situa??es de discord?ncia entre os revisores. Os crit?rios de qualidade dos artigos foram avaliados mediante instrumento QUADAS e na medicina baseada em evid?ncias. Resultados: Sete artigos foram inclu?dos na presente revis?o sistem?tica, totalizando 314 pacientes com idade m?dia de 32,5 anos. Houve um aumento em m?dia de 47,6 metros no Teste de Caminhada de 6 Minutos os programas de reabilita??o pr?-pulmonar e 122 metros no programa p?s- reabilita??o. O consumo de oxig?nio de pico (VO2 peak) aumentou em m?dia em 0,41 nos programas de reabilita??o p?s-transplante, atrav?s de cicloerg?metros. Os dom?nios de sa?de f?sica e mental do question?rio SF-36 obtiveram aumentos significativos no per?odo pr?-transplante. Houve melhora significativa em todos os dom?nios do SF-36 com o programa de reabilita??o p?s-transplante pulmonar. Apenas 1 artigo utilizou o question?rio Chronic Respiratory Questionnaire (CRQ) no per?odo p?s-transplante pulmonar, que referenciou melhora apenas no quesito dispneia com um aumento de 0,6 pontos. Conclus?o: A reabilita??o pulmonar ? uma interven??o efetiva para o manejo tanto pr? quanto p?s-transplante pulmonar. Os achados encontrados sugerem mudan?as relevantes na capacidade funcional e na qualidade de vida desses pacientes. Metodologicamente, os estudos devem prover dados precisos e v?lidos para a reabilita??o pulmonar pr? e p?s-transplante. Novos ensaios cl?nicos sobre os benef?cios da reabilita??o devem ser iniciados, mantendo a preocupa??o com a ?tica, a randomiza??o, em rela??o aos grupos homog?neos e com os desafios log?sticos desses ensaios.
|
6 |
An?lise da resposta de fator de necrose tumoral-alfa e interleucina-10 no lavado traqueobr?nquico de rec?m-nascidos prematuros submetidos ventila??o mec?nicaCorso, Andr?a L?cia 25 August 2006 (has links)
Made available in DSpace on 2015-04-14T13:32:37Z (GMT). No. of bitstreams: 1
312693-2_protected.pdf: 2061691 bytes, checksum: ddde3037f4a47aecbfeeb5308651bd9e (MD5)
Previous issue date: 2006-08-25 / Objetivos: Analisar a resposta inflamat?ria pulmonar em rec?m-nascidos (RNs) prematuros em ventila??o mec?nica atrav?s da mensura??o seriada do fator de necrose tumoral-α (TNF-α) e interleucina (IL) -10 no lavado traqueobr?nquico (LTB), verificando a sua associa??o com fatores perinatais e com fun??o pulmonar. Pacientes e M?todos: prematuros com idade gestacional igual ou inferior a 32 semanas, que necessitaram de ventila??o mec?nica nas primeiras 24 horas por insufici?ncia ventilat?ria foram selecionados para o estudo. Foram mensuradas as concentra??es das interleucinas TNF-α e IL-10 no LTB coletado dentro das primeiras 24 a 48 horas de intuba??o endotraqueal pela t?cnica de ELISA. Amostras subseq?entes foram colhidas nos dias 3, 5, 7, 10, 15 e 20 ap?s intuba??o, naqueles RNs que permaneceram em ventila??o mec?nica por esse per?odo. Os pacientes foram acompanhados no ambulat?rio de Pneumologia Pedi?trica e foram realizados testes de fun??o pulmonar ap?s 40 semanas de idade corrigida.
Resultados: Foram obtidas 70 amostras seq?enciais de LTB de 25 prematuros inclu?dos no estudo. N?veis detect?veis de TNF-α foram observados em quarenta e sete amostras (67%) e de IL-10 em dezoito (26%). N?o houve associa??o significativa dos n?veis de TNF-α e IL-10 com idade gestacional, peso ao nascimento, doen?a da membrana hialina, tempo em ventila??o mec?nica, dura??o de suplementa??o de oxig?nio e ?bito. Nas amostras coletadas no dia 2, foi encontrada uma associa??o significativa entre a concentra??o de TNF-a e IL-10 e o tempo de ruptura das membranas amni?ticas (p = 0,002, r = 0,652 e p < 0,001, r = 0,57, respectivamente). Em rela??o ao estudo da fun??o pulmonar, houve uma associa??o negativa entre a concentra??o de TNF-a no dia 2 e o FEF75 (p = 0,03 e r = 0,7). Conclus?es: TNF-α e IL-10 s?o detect?veis no LTB de prematuros em ventila??o mec?nica. Foi observada uma rela??o direta entre suas concentra??es e o tempo de ruptura das membranas amni?ticas. Houve uma correla??o inversa significativa entre os n?veis de TNF-α e o FEF75 nos pacientes submetidos ao teste de fun??o pulmonar.
|
7 |
Avalia??o de um modo de ventila??o mec?nica experimental em ventilador convencionalRovaris, Fernanda Velho 23 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:32:50Z (GMT). No. of bitstreams: 1
432631.pdf: 1291691 bytes, checksum: dd151d1233cec72e309aa31b59c82e9c (MD5)
Previous issue date: 2011-03-23 / Objetivo: Comparar dois m?todos de ventila??o mec?nica em porcos rec?m-nascidos com doen?a pulmonar grave, em um modelo animal de doen?a da membrana hialina. M?todos: Nove porcos rec?m-nascidos, sexo masculino, peso m?dio 1720g, foram inclu?dos no estudo, anestesiados e artificialmente depletados de surfactante end?geno, atrav?s de sucessivas lavagens pulmonares com soro fisiol?gico, at? atingir uma PaO2 < 60 mmHg em ventila??o com 100% de oxig?nio e TME < 100 (teste das microbolhas est?veis) no aspirado traqueal. Posteriormente, os porcos foram divididos em (1) grupo tempo inspirat?rio curto (n=5) e (2) grupo em ventila??o convencional (n=4). Gasometrias e mec?nica ventilat?ria foram avaliadas antes e ap?s a lavagem pulmonar e ap?s 60 e 120 minutos de tratamento. Foi realizado an?lise morfom?trica ap?s a retirada dos pulm?es. Os testes estat?sticos utilizados foram teste t e ANOVA. Resultados: As caracter?sticas dos animais eram semelhantes nos grupos e n?o houve diferen?a significativa nos valores das gasometrias arteriais e da mec?nica ventilat?ria nos quatro momentos do estudo, mas o grupo 2 apresentou uma tend?ncia ? hiperventila??o. Conclus?o: Neste estudo, todos os animais desenvolveram doen?a pulmonar grave e apresentaram melhora significativa nos dois modos de ventila??o.
|
8 |
Escore de risco para ventila??o mec?nica prolongada em pacientes p?s-cirurgia de revasculariza??o mioc?rdicaDallazen, Fernanda 05 October 2018 (has links)
Submitted by PPG Medicina e Ci?ncias da Sa?de (medicina-pg@pucrs.br) on 2018-12-11T13:17:23Z
No. of bitstreams: 1
FERNANDA DALLAZEN.pdf: 1913250 bytes, checksum: 643c26e233052ab4843690b459dd637d (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-12-13T12:27:07Z (GMT) No. of bitstreams: 1
FERNANDA DALLAZEN.pdf: 1913250 bytes, checksum: 643c26e233052ab4843690b459dd637d (MD5) / Made available in DSpace on 2018-12-13T12:40:00Z (GMT). No. of bitstreams: 1
FERNANDA DALLAZEN.pdf: 1913250 bytes, checksum: 643c26e233052ab4843690b459dd637d (MD5)
Previous issue date: 2018-10-05 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Objective: To construct a risk score model for prolonged mechanical ventilation (PMV) in patients undergoing coronary after bypass grafting (CABG). Methods: An observational, retrospective and historical cohort study, with 4.165 patients submitted to coronary artery bypass grafting, between January 1996 and December 2016. The duration of ?12 hours on mechanical ventilation defined as prolonged. The multiple logistic regression was used to evaluate the predictor variables. The modeling database, divided in 2/3 of the sample (2.746 patients) generated the preliminary model and its performance was tested in the validation database, divided in 1/3 of the sample (1.419 patients). The final risk score was validated in the total database and the accuracy of the model was tested by performance statistics. Results: The incidence of PMV was 18.8% (783). The variables associated with prolonged PMV were: age ?65 years (OR=1.91; [CI95%=1.62-2.24]; p<0.001); urgent/emergency surgery (OR=2.79; [CI95%=2.09-3.73]; p<0,001); obesity (OR=1.49; [CI95%= 1.21-1.84]; p<0.001); chronic renal failure (OR=1.98; [CI95%=1.61-2.44]; p<0.001); chronic obstructive pulmonary disease (OR=1.43; [CI95%=1.16-1.76];p<0,001) and extracorporeal circulation time ?120 minutes (OR=1.75; [IC95%=1.42-2.16]; p<0.001). The area under de the ROC curve was 0.66 (IC95%=0.64-0.68), the chi-square was 3.38 and the correlation coefficient of r=0.99 (p<0.000). Conclusion: The preoperative predictor variables (age ?65 years, urgent/emergency surgery, obesity, chronic renal failure and chronic obstructive pulmonary disease) and perioperative (extracorporeal circulation time ?120 minutes) were associated with PMV and allowed the constructed of risk score classified in low, medium, high and very high. / Objetivo: Construir um modelo de escore de risco para ventila??o mec?nica prolongada (VMP) em pacientes p?s-cirurgia de revasculariza??o mioc?rdica (CRM).
M?todos: Estudo observacional, retrospectivo e de coorte hist?rica, com 4.165 pacientes submetidos ? CRM, entre janeiro de 1996 a dezembro de 2016. A perman?ncia >12 horas em ventila??o mec?nica foi definida como prolongada. A regress?o log?stica m?ltipla foi utilizada para avaliar as vari?veis preditoras. O banco de dados modelagem, dividido em 2/3 da amostra (2.746 pacientes) gerou o modelo preliminar e seu desempenho foi testado no banco valida??o, dividido em 1/3 da amostra (1.419 pacientes). O escore final foi validado no banco total e a acur?cia do modelo foi testada pelas estat?sticas de desempenho.
Resultados: A incid?ncia de VMP foi de 18,8% (783). As vari?veis associadas ? VMP foram: idade ?65 anos (OR=1,91; [IC95%=1,62-2,24]; p<0,001); cirurgia de urg?ncia/emerg?ncia (OR=2,79; [IC95%=2,09-3,73]; p<0,001); obesidade (OR=1,49; [IC95%= 1,21-1,84]; p<0,001); insufici?ncia renal cr?nica (OR=1,98; [IC95%=1,61-2,44]; p<0,001); doen?a pulmonar obstrutiva cr?nica (OR=1,43; [IC95%=1,16-1,76]; p<0,001) e tempo de circula??o extracorp?rea ?120 minutos (OR=1,75; [IC95%=1,42-2,16]; p<0,001). A ?rea sob a curva ROC foi 0,66 (IC95%=0,64-0,68), o qui-quadrado de 3,38 (p=0,642) e o coeficiente de correla??o de r=0,99 (p<0,000).
Conclus?o: As vari?veis preditoras pr?-operat?rias (idade ?65 anos, cirurgia de urg?ncia/emerg?ncia, obesidade, insufici?ncia renal cr?nica e doen?a pulmonar obstrutiva cr?nica) e perioperat?ria (tempo de circula??o extracorp?rea ?120 minutos) estiveram associadas com a VMP e permitiram a constru??o do escore de risco classificado em baixo, m?dio, alto e muito alto.
|
9 |
Ventila??o e prescri??es urban?sticas: uma aplica??o simulada para a Orla da Praia do Meio em Natal/RNMarques, Ricardo Souza 21 July 2003 (has links)
Made available in DSpace on 2014-12-17T13:56:50Z (GMT). No. of bitstreams: 1
RicardoSM.pdf: 5804329 bytes, checksum: 9deae83693b85d7c92acfe8d4535dbbd (MD5)
Previous issue date: 2003-07-21 / This work analyses a study on natural ventilation and its relation to the urban legislation versus the building types in an urban fraction of coastal area of Praia do Meio in the city of Natal/RN, approaching the type or types of land use most appropriate to this limited urban fraction. The objective of this study is to analyse the effects of the present legislation as well as the types of buildings in this area on the natural ventilation. This urban fraction was selected because it is one of the sites from where the wind flows into the city of Natal. This research is based on the hypothesis stating that the reduction on the porosity of the urban soil (decrease in the set back/boundary clearance), and an increase in the form (height of the buildings) rise the level of the ventilation gradient, consequently causing a reduction on the wind speed at the lowest part of the buildings. Three-dimensional computational models were used to produce the modes of occupation allowed in the urban fraction within the area under study. A Computational Fluid Dynamics (CFD) software was also used to analyse the modes of land occupation. Following simulation, a statistical assessment was carried out for validation of the hypothesis. It was concluded that the reduction in the soil porosity as a consequence of the rates that defined the minimum boundary clearance between the building and the boundary of the plot (and consequently the set back), as well as the increase in the building form (height of the buildings) caused a reduction in the wind speed, thus creating heat islands / Analisa um estudo da ventila??o natural e sua rela??o com as prescri??es urban?sticas x tipologia edil?cia numa fra??o urbana da Orla da Praia do Meio em Natal/RN, abordando qual ou quais usos mais se adequam ? fra??o urbana delimitada. Tem como objetivo analisar os efeitos das normas e das tipologias edil?cias sobre a ventila??o natural. A fra??o urbana foi escolhida por ser uma das ?reas de entrada dos ventos em Natal/RN. A pesquisa parte da hip?tese de que a redu??o da porosidade da malha urbana (diminui??o dos recuos) e o aumento do gabarito (altura das edifica??es), elevam o n?vel do gradiente de ventila??o, reduzindo conseq?entemente a velocidade dos ventos nas camadas mais baixas das edifica??es. A abordagem foi desenvolvida atrav?s de modelos computacionais tridimensionais, produzindo os modos de ocupa??o permitidos na fra??o urbana da ?rea de estudo, submetidos posteriormente ? an?lise computacional em software de Mec?nica de Fluidos. Ap?s simula??o, realizou-se avalia??o estat?stica, para valida??o das hip?teses. Concluiu-se que a diminui??o da porosidade em conseq??ncia da redu??o dos ?ndices que definem os afastamentos m?nimos (recuos) entre o edif?cio e o limite do lote (e conseq?entemente entre os edif?cios), e o aumento do gabarito das edifica??es (altura da edifica??o) reduziram a velocidade dos ventos, possibilitando assim a forma??o de ilhas de calor
|
10 |
Ventila??o e prescri??es urban?sticas: uma aplica??o simulada no bairro de Petr?polis em Natal/RNCosta, Fernando Jos? de Medeiros 18 April 2001 (has links)
Made available in DSpace on 2014-12-17T13:57:18Z (GMT). No. of bitstreams: 1
FernandoJMC_ate_referencias.pdf: 2000893 bytes, checksum: 7383eee0619fc2770d78eab5d841f5cd (MD5)
Previous issue date: 2001-04-18 / The present work studies the natural ventilation and its relationship with the urban standards, which establishes the form of occupation and use of the land in our cities. The method simulates the application of the urban standards of the City Master Plan over the last three years. The simulation takes place in the District of Petr?polis, in the city of Natal , Brazil and analyses the effects of the standards of natural ventilation. The formulated hypothesis states that the reductions in the urban spaces between buildings rises up the vertical profile of ventilation, reducing, therefore, the velocity of the wind at the lower levels of the buildings. To develop the study, occupation models were built, using computerized, three-dimensional models. These occupation models were analyzed using the CFD (Computational Fluid Dynamics) code. The conclusion is that the more we reduce the urban space between buildings, the more we reduce the wind speed in constructed areas, increasing, therefore, the possibility to generate heat islands / O objetivo deste trabalho ? o estudo da ventila??o natural e a sua rela??o com as normas edil?cias. O trabalho simula a aplica??o das prescri??es urban?sticas dos ?ltimos tr?s Planos Diretores de Natal em um trecho do tecido urbano do bairro de Petr?polis, analisando os efeitos sobre a ventila??o natural. A pesquisa parte da hip?tese de que a redu??o dos recuos e a conseq?ente diminui??o da porosidade na massa edificada, eleva o n?vel do gradiente de ventila??o, reduzindo a velocidade dos ventos nos n?veis mais baixos das edifica??es. Para o desenvolvimento do estudo, s?o produzidos modelos de ocupa??o com recursos de modelagens computadorizadas em tr?s dimens?es, as quais s?o posteriormente submetidas ? an?lise em programa de Mec?nica dos Fluidos Computadorizada. Conclui-se que a redu??o sucessiva nos ?ndices que definem os afastamentos m?nimos entre os edif?cios, produz a redu??o da velocidade dos ventos em ?reas adensadas, aumentando a possibilidade de forma??o de ilhas de calor
|
Page generated in 0.0689 seconds