• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 54
  • 46
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 209
  • 209
  • 109
  • 73
  • 69
  • 58
  • 49
  • 49
  • 47
  • 40
  • 38
  • 36
  • 31
  • 29
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Determinação simultânia de Cd/Pb em cimento usando TI como padrão interno e de Cr/Mn em alumina por espectrometria de absorção atômica com amostragem de suspensão / Simultaneous determination of Cd/Pb in cement using Tl as internal standard and Cr/Mn in alumina by atomic absorption spectrometry with slurry sampling

Alexandre Luiz de Souza 18 September 2007 (has links)
O objetivo desse trabalho foi o desenvolvimento de métodos analíticos para a determinação simultânea de Cd/Pb em cimento e Cr/Mn em alumina por espectrometria de absorção atômica com atomização eletrotérmica (SIMAAS) e amostragem de suspensão. Considerando os erros de amostragem de suspensão e as condições compromissadas impostas para a determinação simultânea, foi também objetivo do trabalho estudar a aplicação de padrão interno para corrigir erros sistemático e aleatório. A viabilidade de se usar o Tl como padrão interno foi explorada na determinação de Cd e Pb em cimento. O uso do padrão interno se baseou na hipótese de que o elemento Tl deveria adsorver quantitativamente sobre as partículas do material em suspensão. Foi feito o estudo térmico dos elementos Cd, Pb e Tl em soluções aquosas e suspensões, na presença e ausência de diferentes modificadores químicos. O melhor modificador químico (5 µg Pd + 3 µg Mg) foi escolhido com base nos gráficos de correlação. As melhores temperaturas de pirólise e atomização para a determinação simultânea de Cd e Pb foram 600°C e 2000°C, respectivamente. A preparação das amostras foi feita com suspensões contendo 30 µg L-1 de Tl em 0,1 % (v v-1) de HNO3 + 0,025 % (m v-1) de Triton X-100. A avaliação da exatidão foi feita com a determinação de Cd e Pb em cimento de construção civil e dentário com análise de solução e análise de materiais de referência de sedimento marinho (MESS1 e BCSS 1) e de rio (Buffalo River, IEAEA 356). Os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD) obtidos foram 0,14 µg L-1 (1,4pg) para o Cd e de 1,2 µg L-1 (12 pg) para Pb. As massas características foram 1,2 pg e 25 pg para Cd e Pb, respectivamente. Na determinação simultânea de Cr e Mn em alumina não foi utilizado padrão interno. O estudo envolveu a obtenção de curvas de pirólise e atomização em presença de diferentes modificadores. Estudos de interferência mostraram que 100 mg L-1 de Al provocaram aumento nos sinais analíticos dos elementos que foi eliminado com o modificador químico NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combinado com 350 µg de Nb. Nessa condição as temperaturas de pirólise e atomização foram 1400°C e 2400°C, respectivamente. As suspensões de alumina foram preparadas em 2 % (v v-1) HNO3. A avaliação da exatidão foi feita com a determinação de Cr e Mn em material de referência de alumina (Alumina Reduction Grade - 699) e os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD), estimados a partir da variabilidade de 20 medidas consecutivas de uma solução contendo 2 % (v v-1) HNO3 foram 0,11 µg L-1 (2,2 pg) para Cr e 0,17 µg L-1 (3,5 pg) para o Mn. As massas características foram 10 pg e 1,3 pg para Cr e Mn, respectivamente. / The aim of this work was the development of analytical methods for the simultaneous determination of Cd/Pb in cement and Cr/Mn in alumina by electrothermal atomic absorption spectrometry (SIMAAS) and slurry sampling. Considering the errors of slurry sampling and the imposed compromissed conditions for the simultaneous determination, it was also the aiming of this work to study the application of internal standard for the sistematic and random errors correction. The viability of using Tl as internal standard was investigated for Cd and Pb determination in cement. The internal standard aplicability was based on the hypothesis of the element Tl would have to adsorver quantitatively on the particles of the material in suspension. The thermal behaviour of Cd, Pb and Tl in aqueous solutions and suspensions was obtained in presence and absence of different chemical modifiers. The best chemical modifier (5 mg Pd + 3 mg Mg) was chosen based on correlation graphs. The pyrolysis and atomization temperatures for the simultaneous determination of Pb were 600°C and 2000°C, respectively. The sample the preparation was made with 30 mg L-1 of Tl in 0,1% (v v-1) of HNO3 + 0.025% (m v-1 of Triton X-100. The evaluation of the accuracy was made with the determination of Cd and Pb in cement, microwave extraction in acid media and analysis of marine sediment reference materials (MESS1 and BCSS 1) and river sediment (Buffalo River, IEAEA 356). The results are concordant at 95% of confidence level using Studen\'s t-test. The detention limits (LD) was 0.14 µg L-1 (1.4 pg) for Cd and 1.2 µg L-1(12 pg) for Pb. The characteristic masses were 1.2 pg and 25 pg for Cd and Pb, respectively. The simultaneous determination of Cr and Mn in alumina was done without internal standard. Pyrolysis and atomization temperaturas were obtained in presence of different modifiers. Studies of interference shown that 100 mg L-1 of Al provoked increase in the analytical signals of Cr and Mn that was eliminated with the chemical modifier NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combined with 350 mg of Nb as permanent chemical modifier. In this condition pyrolysis and atomization temperatures were 1400 °C and 2400 °C, respectively. The alumina suspensions were prepared in 2% (v v-1) HNO3. The evaluation of the accuracy was made with the determination of Cr and Mn in alumina reference material (Reduction Alumina Grating - 699) and the results were concordant at 95 % of the confidence level using Student\'s t-test. The detention limits (LD) were 0.11 µg L-1 (2.2 pg) for Cr and 0.17 µg L-1 (3.5 pg) for Mn. The characteristic masses were 10 and 1.3 pg for Cr and Mn, respectively.
32

The Determination for Cadmium in Biological Materials

Young, Ronald E. 12 1900 (has links)
<p> With the increasing concern about pollution the need has arisen for accurate trace analysis of hazardous or toxic trace elements such as cadmium. While the modern analytical chemist has at his disposal a great many different techniques for analysis, surveys of inter-laboratory analyses have often produced serious discrepancies among results done by different methods and/or workers. The purpose of this thesis will be to review the different methods for trace analysis of cadmium in biological samples and to experimentally compare two of these, atomic-absorption spectrometry and neutron-activation analysis.</p> / Thesis / Master of Science (MSc)
33

Design and Synthesis of Novel Cage-Functionalized Crown Ethers: A New Class of Ag Complexants.

Lai, Huiguo 08 1900 (has links)
Three different types of cage crown ethers have been prepared and their complexation properties with Ag(I) have been studied. Atomic absorption, fluorescence quenching, and UV absorption have been used to study the interaction between the hosts (cage crown ethers) and guests (Ag+). For the cage-annulated crown ethers that contain aromatic rings, cation-π and π-π interactions may contribute significantly to the overall complexation ability of the host system. Piperazine groups may cooperate, and the piperazine nitrogen atoms provide unshared electrons, which may form a complex with Ag+. In addition, relatively soft donor atoms (e.g., Br) are well-suited for complexation with Ag+, which is a softer Lewis acid than alkali metal cations.
34

Estudo da influência de processos de conservação na distribuição de espécies elementares em água de coco por espectrometria de absorção e emissão atômica / Study of influence of conservation processes in the distribution of elemental species in coconut water by atomic absorption spectrometry and optical emission spectrometry

Naozuka, Juliana 23 July 2004 (has links)
A água de coco é um isotônico natural, uma bebida pouco calórica e muito nutritiva, representando 1,4 % do mercado de refrigerantes e de isotônicos artificiais. Aliado ao crescente mercado interno e externo, surge os processos de conservação com o intuito de preservação da água de coco fora do fruto, facilitando a comercialização e aumentando o tempo de vida de prateleira. Considerando o pressuposto, esse trabalho teve como objetivo principal avaliar a influência dos processos de conservação, ultrafiltração, congelamento e pasteurização, na concentração de Al, Ca, Cu, Fe, K, Mg, Mn, Na, Se e Zn em água de coco. As determinações foram feitas por espectrometria de emissão óptica com plasma indutivamente acoplado e espectrometria de absorção atômica com atomização eletrotérmica. Investigação no sentido de determinar espécies livres de Se4+ e Se6+, em água de coco, por geração de hidretos e pré-concentração na superfície de um tubo de grafite modificada com Ir também foi objetivo desse trabalho. Os estudos foram realizados por meio das determinações das concentrações totais dos elementos e em diferentes frações (filtrado e resíduo), obtidas após ultrafiltração com membrana de celulose (0,100 e 0,025 &#181;m). Em todos os processos de conservação estudados, exceto na ultrafiltração, as concentrações totais dos elementos de interesse foram preservadas. A ultrafiltração com filtro de 0,025 &#956;m promoveu a retenção de uma quantidade significativa de Fe (30%) e Zn (50 %). A influência dos processos de conservação, com base na distribuição dos elementos de interesse, mostrou uma tendência de variação na distribuição de Cu, Fe e Zn na água de coco pasteurizada e em todos os elementos na congelada, sobretudo para aquelas com tempo de congelamento superior a 30 dias. A especiação de Se6+ e Se4+ foi feita após redução do Se6+ com 2,0 mol L-1 HCl + 1 mol L-1 KBr e aquecimento por microondas focalizadas em microfrascos, apresentando cerca de 95 % de eficiência na redução na ausência da amostra de água de coco. / The coconut water is a natural isotonic, nutritive and low caloric drink, corresponding to 1.4 % of the soft drink and artificial isotonic market store. The conservation processes of the coconut water appear in association to the expansion of the internal and external market, increasing the shelf-life of the product and its comercialization. The objective of this work was evaluate the influence of the conservation processes, such as, ultrafiltration, freezing and pasteurization based on the concentrations of Al, Ca, Cu, Fe, K, Mg, Mn, Na, Se and Zn in the coconut water. The determinations were done by inductively coupled plasma-optical emission spectrometry and electrothermal atomic absorption spectrometry. The investigation of free-species of Se4+ and Se6+, in coconut water, by hydride generation and pre-concentration on the modified graphite tube surface with Ir was also the aim of this project. The studies were carried out through the determinations of the total concentration of the interest elements and in different fractions (filtrate and residue), obtained after ultrafiltration with cellulose membrane filters (0.100 and 0.025 &#181;m). In all processes of conservation studied, except the ultrafiltration, the total concentrations were preserved. The ultrafiltration with filters of 0.025 &#181;m promoted the retention of significant concentration of Fe (30%) e Zn (50%). Considering the distribuituion of the interest elements, the influence of the conservation processes showed a tendency of the variation in the Cu, Fe and Zn distribuition for the pasteurized coconut water, and for all elements in the frozen, mainly for frozen samples storaged for more than 30 days. The speciation of Se4+ and Se6+ was carried out after reduction of Se6+ with 2 mol L-1 HCl + 1 mol L-1 KBr and using microvials heated in a focused microwave. The reduction efficiency of the Se6+ to Se4+ was 95 %, in absence of coconut water.
35

"Avaliação da concentração de metais em amostras de sedimentos do Reservatório Billings, Braço Rio Grande, São Paulo, Brasil" / Assessment of metal concentrations in sediment samples from Billings reservoir, Rio Grande tributary, São Paulo, Brazil

Bostelmann, Eleine 22 June 2006 (has links)
O presente estudo consistiu em caracterizar quimicamente amostras de sedimentos da represa Billings, braço Rio Grande, na região Metropolitana de São Paulo, por meio da determinação da concentração de metais e outros elementos de interesse. Os parâmetros químicos escolhidos para esta caracterização, foram as concentrações de Alumínio, Arsênio, Bário, Cádmio, Chumbo, Cobre, Cromo, Ferro, Manganês, Mercúrio, Níquel, Selênio e Zinco. Esses parâmetros são também utilizados na determinação do Índice de Qualidade das Águas (com exceção do Selênio). As determinações foram efetuadas pelas técnicas analíticas de espectrometria de absorção atômica (FAAS, GFAAS e CVAAS), espectrometria de emissão ótica (ICP OES) e análise por ativação neutrônica (AAN). Essas metodologias analíticas foram avaliadas quanto à precisão, exatidão e limite de detecção e/ou quantificação para os elementos determinados, nas amostras de sedimentos. Foram discutidas também as vantagens e desvantagens de cada técnica utilizada, para cada elemento, dependendo de sua concentração. A partir dessa análise, selecionou-se a técnica mais apropriada para a determinação de cada elemento, para a implementação em análise de rotina de amostras de sedimentos. Dessa forma verificou-se que a digestão efetuada assistida por microondas em sistema fechado com ácido nítrico é eficiente para a quantificação da concentração de metais extraíveis de interesse ambiental. Verificou-se também que as técnicas escolhidas para as determinações dos metais eram igualmente eficientes. No caso dos metais Cd e Pb, com a técnica de FAAS obteve-se resultados melhores do que a técnica de ICP OES, por não apresentar interferência de matriz. Os valores de concentração para os metais As, Cd, Cu, Cr, Hg, Ni, Pb e Zn nas amostras de sedimentos foram comparados com os valores orientadores (TEL e PEL) do Canadian Council of Minister of the Environment (CCME). Esse projeto definiu as técnicas analíticas e parâmetros, para um melhor monitoramento dos níveis de contaminação de sedimentos por metais, fornecendo dados que possam ser utilizados para direcionar atitudes e manejos de sistemas aquáticos. / The present study chemically characterized sediment samples from the Billings reservoir, Rio Grande tributary, in the Metropolitan region of São Paulo, by determining metal concentration and other elements of interest. The chosen chemical parameters for this characterization were Aluminum, Arsenic, Barium, Cadmium, Copper, Chromium, Iron, Lead, Manganese, Mercury, Nickel, Selenium and Zinc. These parameters are also used in the water quality index, with the exception of Selenium. The concentrations were determined through different analytical techniques such as atomic absorption spectrometry (FAAS, GFAAS and CVAAS), optical emission spectrometry (ICP OES) and neutron activation analysis. These analytical methodologies were assessed for precision, accuracy and detection and/or quantification limits for the sediment elements in question. Advantages and disadvantages of each technique for each element and its concentration were also discussed. From these assessment the most adequate technique was selected for the routine analysis of sediment samples for each element concentration determination. This assessment verified also that digestion in a closed microwave system with nitric acid is efficient for the evaluation of extracted metals of environmental interest. The analytical techniques chosen were equally efficient for metals determination. In the case of Cd and Pb, the FAAS technique was selected due to better results than ICP OES, as it does not present matrix interference. The concentration values obtained for metals As, Cd, Cu, Cr, Hg, Ni, Pb and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) TEL and PEL values.
36

Carbonato de lítio: utilização da espectrofotometria de absorção atômica em bioequivalência e perfil de uso na pediatria. / Lithium carbonate: atomic absortion spectrophotometry in bioequivalence and pediatric pattern of use.

Guilherme, Marcia Cristina Guimarães 16 July 2007 (has links)
A tese objetivou beneficiar pacientes usuários de lítio por meio de dois estudos: (1) análise da bioequivalência de duas formulações de lítio; e (2) investigação do uso do lítio na pediatria. Para o estudo de bioequivalência, voluntários sadios (N=24) foram tratados com comprimidos (300mg) de carbonato de lítio de duas formulações: teste-Neurolithium e referência-Carbolitium. Após administrar cada formulação em períodos diferentes, foram coletadas amostras de plasma para quantificar íons lítio, utilizando espectrofotometria de absorção atômica. O método desenvolvido neste estudo apresentou limite de quantificação de 0,07mg/L. A média geométrica e o intervalo de confiança de 90% teste/referência foi de 104,77 (98,60-111,33%) para Cmax e 101,99 (96,81-107,44%) para ASClast. Seguindo os parâmetros propostos pelo FDA e ANVISA, concluiu-se que o Neurolithium é bioequivalente ao Carbolitium. Desta forma, este estudo assegura a comercialização de uma formulação de qualidade e o possível registro de um medicamento genérico com custo reduzido. O FDA não recomenda o uso de lítio em crianças menores de 12 anos, pois ainda não tem informações sobre segurança e eficácia da medicação nesses pacientes. Assim, o segundo estudo investigou o uso do lítio em pacientes pediátricos, divididos em dois grupos: (A) menores e (B) maiores de 12 anos. Pacientes que receberam prescrição de lítio no HC da Unicamp, entre 2000 e 2006, foram identificados e os prontuários médicos dos menores de 21 anos (N=77) foram revisados. Houve administração de menores doses nos pacientes do grupo A. Os níveis séricos e índice de efeitos colaterais não diferiram entre os grupos. O grupo A apresentou motivo de prescrição de lítio (agressividade) e eficácia (71%) diferentes do grupo B (alterações de humor; 83%). Uma vez que os índices de eficácia dos grupos foram condizentes com os da literatura e não houve diferença no aparecimento de efeitos colaterais, concluiu-se que é viável a utilização de lítio em menores de 12 anos. / The ideal of this thesis is to benefit patients that use lithium, through two studies: (1) comparison of the bioavailability of two lithium formulations; and (2) investigation of lithium use in children and adolescents. In order to analyze the bioequivalence, healthy volunteers (N=24), of both genders, were treated with two lithium carbonate formulations (300 mg): test ? Neurolithium and reference-Carbolitium. After administrate each formulation in separate periods, plasma samples were collected to quantify lithium, using atomic absorption spectrophotometry. The method was developed specially to this study and it showed 0,07mg/L quantification limit. The geometric media and the 90% confiance interval test/reference was 104,77 (98,60-111,33%) to Cmax and 101,99 (96,81-107,44%) to ASClast. Based on FDA and ANVISA parameters, we concluded that Neurolithium is bioequivalent to Carbolitium. Therefore, this study assures the commercialization of a qualified formulation and makes possible the register of a generic medication with low cost. Since information regarding the safety and effectiveness of lithium in children under 12 years of age is not available, its use in such patients is not recommended at this time. Therefore, the second study has investigated the use of lithium in pediatric patients, divided in two groups: (A) under and (B) over 12 years old. Patients that received lithium prescription inside of HC in Unicamp, between 2000 and 2006, were identified. Only clinical register of patients (N=77) under 21 years old, were revised. Fewer doses were administrated in group A. Seric levels and side effects indexes were not different between groups. Group A showed reason for lithium prescription (aggressiveness) and effectiveness (71%) different from group B (humor oscillation; 83%). Since indexes effectiveness from both groups were in accordance with those found in literature and there was no difference in side effects number per patient, we concluded that the use of lithium in patients under 12 years old is feasible.
37

Explorando a espectrometria de absorção atômica com atomização eletrotérmica e amostragem direta em superfície metálica para a determinação de bário / Feasibility to use metalic platform to the graphite tube of the electrothermal atomic absorption spectrometry for barium determination

Scatamachia, Daniela de Santi 17 March 2006 (has links)
A eficiência de atomização do bário, em superfície grafítica, é fortemente afetada pela formação de espécies refratárias, como carbetos e óxidos. Várias tentativas vêm sendo propostas no sentido de melhorar o limite de detecção do bário em espectrometria de absorção atômica com forno de grafite. Nesse sentido, o presente trabalho teve como objetivo estudar a viabilidade de se utilizar uma plataforma de tungstênio adaptada ao tubo de grafite do espectrômetro de absorção atômica, visando melhorar a eficiência de atomização do bário bem como a sua determinação em petróleo, óleos lubrificantes, água do mar e água mineral. O sistema proposto constituiu-se de uma plataforma de tungstênio com superfície modificada eletroliticamente com ródio, adaptada a um tubo de grafite com parede interna modificada com irídio. A mistura de 10% (v/v-1) H2 + 90% (v/v-1) Ar como gás de purga aumentou a eficiência de atomização, o tempo de vida do tubo de grafite e da plataforma. O uso de 10 µg de (NH4)2HPO4 como modificador químico foi indispensável para a determinação de bário em água mineral e de mar. O limite de detecção foi de 3,5+/-0,3 µg L-1 e a massa característica de 2,1 pg. Com a plataforma de tungstênio modificada com ródio foi possível gerar um sinal transiente de absorbância com temperatura de atomização de 2400 oC, com tempo de residência de, aproximadamente, 0,5 s, contra uma temperatura de atomização de 2600 oC para o forno de grafite, com tempo de residência de 15 s. A vida útil da plataforma de tungstênio, modificada com ródio, e do tubo de grafite foram, respectivamente, 200 e 750 ciclos de aquecimento. / The atomization efficiency of barium in graphite furnace is strongly affected by the refractory species formation, such as, carbides and oxides. Several attempts have been done to overcome these drawbacks and to improve the sensitivity of barium in electrothermal atomic absorption spectrometry. Thus the aim of the present work was to propose a tungsten platform inserted into the graphite tube of the atomic absorption spectrometer for the determination of barium in petrol, lubrificating oil, drinking water and seawater. The proposed system consisted of a tungsten platform electrolitically modified with rhodium and a graphite tube with the internal wall modified with iridium. The mixture of 10 % (v/v-1) H2 + 90% (v/v-1) Ar was used as purge gas, increasing the atomization efficiency, the graphite tube and the tungsten platform lifetime. The use of 10 µg de (NH4)2HPO4 as chemical modifier was imperative for the determination of barium in drinking water and seawater. After the optimization, the detection limit was 3.5+/-0.3 µg L-1 and the characteristic mass was 2.1 pg. By using the tungsten platform modified with rhodium it was possible to obtain a transient absorbance signal at 2400 oC atomization temperature, with residence time of 0.5 s, against 2600 oC atomization temperature in graphite tube platform, with residence time of 15 s. The lifetimes of the tungsten platform modified with rhodium and the graphite tube were 200 and 750 heating cycles, respectively.
38

Estudo de sedimentos da bacia hidrográfica do Moji-Guaçu, com ênfase na determinação de metais. / Studies of sediments Hydrographic Mogi-Guaçu Basin emphasys in the determination of metals.

Silva, Maria Raimunda Chagas 14 May 2002 (has links)
Este trabalho teve como principal objetivo analisar os sedimentos do rio Moji-Guaçu, numa tentativa de avaliação do impacto dos metais sobre o meio ambiente. A Bacia Hidrográfica do Moji-Guaçu, localizada entre os estados de São Paulo e Minas Gerais, é um importante sistema de sustento de diversas atividades econômicas regionalizadas. Em decorrência de atividades antropogênicas, tais como uso e ocupação inadequada do solo; utilização de pesticidas e fertilizantes nas lavouras; lançamento de esgoto sanitários in natura e de efluentes industriais; desmatamento e extração de areia e argila, entre outras, verificou-se que o rio Moji-Guaçu sofre diferentes graus de degradação ao longo do seu curso. Para avaliar os efeitos desses impactos, foram realizadas coletas de sedimentos, em quatro épocas diferentes, duas no período seco (agosto de 2000 e junho de 2001) e duas no chuvoso (novembro de 2000 e março de 2001),15 pontos de coleta distribuídas desde a nascente até a foz. Foram analisadas as porcentagens de matéria orgânica e inorgânica, a granulometria e os metais presentes. A análise qualitativa dos metais foi feita pela técnica espectroscópica de fluorescência de raios-X e a quantitativa foi realizada por absorção atômica. Os resultados mostraram que as porcentagens de matéria orgânica foram consideradas elevada para rios, e ocorreram na quase totalidade dos pontos e em todos os períodos de amostragem. A análise granulométrica indicou a presença de uma elevada fração de argila e silte na maioria dos pontos de amostragem, sugerindo que os sedimentos dos trechos paulista e mineiro têm importante papel na redistribuição dos metais na coluna d'água. A espectroscopia de fluorescência de raios-X mostrou a presença dos metais Zr, Cu, Fe, Cr, Ti, Ca, K, P, S, Si e Al. De um modo geral, as concentrações dos metais totais de Cd, Pb apresentaram-se elevadas para todos os pontos e Fe, Cu, Cr e Mn em alguns pontos, o que pode caracterizar um ambiente impactado e um sistema com alto grau de contaminação e interferência antrópica. / The main objective of this work was to analyze the sediments of the river Moji-Guaçu, to attempt evaluate the impact of the metals on the environment. The Hydrographic Basin of Moji-Guaçu, located in the States of São Paulo and Minas Gerais, is an important support system of several economical activities. It was verified that the river Moji-Guaçu suffers different degrees of degradation along your course due to anthropogenic activities such as: inadequate use and occupation of the soil, use of pesticides and fertilizers in the agriculture, release of sewage and industrial effluents, deforestation and extraction of sand and clay, etc. To evaluate the effects of those impacts, collecting of sediments were accomplished, in four different times, two in the dry period (August of 2000 and June of 2001) and two in the rainy period (November of 2000 and March of 2001), 15 collecting points distributed from the nascent to the mouth. The percentages of organic and inorganic matter, the granulometry of sediment and the metals present were determined. The qualitative analysis of the metals was made by the spectroscopic ray-X fluorescence technique and the quantitative analyses by atomic absorption spectroscopy. The percentages of organic matter were considered high for almost all the points and the periods of samplings. The granulometric analysis indicated the presence of a high fraction of clay and silt in most of the sampling points, suggesting that the sediments have important role in the redistribution of the metals in the water’s column. The ray-X fluorescence showed the presence of Zr, Cu, Fe, Cr, Ti, Ca, K, P, S, and Al. In a general way, the concentrations of the total metals of Cd, Pb showed high for all the points and, Fe, Cu, Cr and Mn in some points, which characterize an impacted environment and a system with high degree of contamination and human interference.
39

\"Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de alumínio\" / \"Evaluation of tungsten coil electrothermal atomic absorption spectrometry for aluminium determination\"

Godoi, Quienly 27 October 2006 (has links)
Este trabalho teve como objetivo avaliar o filamento de tungstênio de 150 W (OSRAM) como atomizador eletrotérmico para determinação de alumínio em amostras de águas, incluindo um estudo sistemático sobre o seu comportamento eletrotérmico na presença de até 1000 mg l-1 de sódio, potássio, cálcio, magnésio e/ou da mistura destes elementos. Alguns parâmetros, como comprimento de onda, corrente da lâmpada de catodo oco, altura de observação e temperatura de atomização do alumínio foram avaliados visando à melhoria da qualidade dos resultados e do limite de detecção. Após uma primeira avaliação, fixaram-se o comprimento de onda em 309,3 nm e a corrente da lâmpada de catodo oco em 10 mA, elegendo-se altura de observação de 1,5 mm e temperatura de atomização de 2860 oC (13,0 V). No programa de aquecimento usado no desenvolvimento deste trabalho adotou-se rampa invertida de voltagem variando entre 0,65 a 0,30 V durante 50 s para secagem de 10 µl, 2,8 V durante 10 s para pirólise e 13,0 V durante 1 s para atomização. As soluções usadas no desenvolvimento deste trabalho formam preparadas, em sua maioria, em meio 0,1 % v/v HNO3. A avaliação dos potenciais interferentes Na, K, Ca, Mg e a mistura desses elementos foi realizada nas alturas de observação de 0,0 a 2,0 mm e nas composições do gás de proteção de 90% Ar/10% H2, 80% Ar/20% H2, 65% Ar/35% H2. Pode-se inferir que o aumento do hidrogênio na composição do gás de proteção não acarretou melhora significativa na ação dos interferentes na atomização do alumínio. Não foram observadas interferências significativas em até 1000 mg l-1 Na e K na atomização de 100 µg l-1 Al na altura de observação de 0,0 mm. Na mesma condição de altura de observação, a mistura dos interferentes não afetou significativamente a atomização do alumínio. Observaram-se interferências em torno de 40 % na atomização de 100 µg l-1 Al em 0,1 % v/v HNO3 na altura de observação de 0,0 mm na presença de até 100 mg l-1 de Ca e Mg. Nessa mesma condição, mas com a mistura 65 % Ar/35 % H2, a supressão do sinal de absorbância de alumínio foi da ordem 90%. Os resultados obtidos na determinação de alumínio em amostras de água foram obtidos nas condições anteriormente citadas, utilizando gás de proteção 90% Ar/ 10% H2. Nestas condições, o limite de detecção foi de 2,3 µg l-1 Al e a massa característica de 69 pg Al. Os resultados encontrados foram satisfatórios e concordantes com aqueles encontrados quando se utilizou o forno de grafite como método de comparação. Aproximadamente 500 queimas foram feitas com um único filamento de tungstênio. / The aim of this paper was to evaluate the 150 W (OSRAM) tungsten coil as electrothermal atomizer in order to determine aluminum in water samples as well as a systematic study of its electrothermal behavior in the presence of up to 1000 mg l-1 of sodium, potassium, calcium, magnesium and/or of mixture of these elements. Some parameters, such as wavelength, hollow cathode lamp current, observation height and atomization temperature were evaluated in order to improve the quality of results and the detection limit. After a first evaluation, measurements were always carried out at 309,3 nm as well as the hollow cathode lamp current at 10 mA, and it was adopted an observation height of 1,5 mm and atomization temperature at 2860 oC (13,0 V). In the heating program defined experimentally, the inverted voltage ramp was adopted for drying 10 &#956;l of sample solution by varying the applied voltage from 0,65 to 0,30 V during 50 s, with further application of 2,8 V for 10 s in the pyrolysis step and 13,0 V for 1 s in the atomization step. Most solutions were prepared in 0,1% v/v HNO3. The evaluation of the potential interfering elements such as Na, K, Ca, Mg an the mixture of these elements, was carried out in observations heights from 0,0 to 2,0 mm at different gas compositions: 90% Ar/ 10% H2 , 80 % Ar/ 20% H2 and 65 % Ar/ 35% H2. It can be inferred that the hydrogen increase in the protection gas did not change the interference behavior of the studied concomitants on aluminum atomization. Significant interferences were not observed up to 1000 mg l-1 of Na and K in the atomization of 100 &#956;g l-1 Al when the optical beam was intercepting the atomizer (0,0 mm observation height). In the same condition, the mixture of the interfering species did not significantly affect the aluminum atomization. In addition, 100 mg l-1 of Ca and Mg depressed the absorbance of 100 &#956;g l-1 Al in 0,1 % v/v HNO3 by approximately 40 %. When the atomization was made in the presence of 65 % Ar/ 35 % H2, the suppression of the aluminum absorbance signal was about 90 %. The results obtained in the determination of aluminum in water samples were achieved in the conditions previously mentioned, using protection gas of 90 % / 10 % H. In these conditions, the detection limit was 2,3 &#956;g l-1 Al and the characteristic mass was 69 pg Al. The results were reasonable and in agreement with those found by atomic absorption with graphite furnace as a comparative method. Approximately 500 firings were made with a single tungsten coil.
40

Direct determination of lead in airborne particulate matter by graphite furnace atomic absorption spectrometry.

January 1997 (has links)
by Lai Yuen Kwan. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1997. / Includes bibliographical references (leaves 41-45). / Abstract --- p.i / Acknowledgement --- p.ii / Contents --- p.iii / List of Figures --- p.vi / List of Tables --- p.vii / Chapter 1. --- INTRODUCTION / Chapter 1.1 --- Air Pollution in Hong Kong --- p.1 / Chapter 1.2 --- Lead in Air and its Harmful Effects on Human --- p.3 / Chapter 1.3 --- Sampling of Air Particulates --- p.6 / Chapter 1.3.1 --- Principles of filter sampling --- p.6 / Chapter 1.3.2 --- Filter media for air sampling --- p.7 / Chapter 1.4 --- Sample Treatment --- p.9 / Chapter 1.4.1 --- Acid digestion - standard method for analysis of metals --- p.9 / Chapter 1.4.2 --- Slurry sampling - direct method for analysis of metals --- p.9 / Chapter 1.4.3 --- Literature survey on slurry sampling --- p.10 / Chapter 1.4.4 --- Comparison between acid digestion and slurry sampling methods --- p.10 / Chapter 1.5 --- Instrumental Analysis --- p.11 / Chapter 1.5.1 --- Graphite furnace atomic absorption spectrometry --- p.11 / Chapter 1.5.2 --- Background correction by the Zeeman effect --- p.12 / Chapter 2. --- EXPERIMENTAL / Chapter 2.1 --- Apparatus --- p.14 / Chapter 2.2 --- Reagents --- p.14 / Chapter 2.3 --- Procedure --- p.15 / Chapter 2.3.1 --- Selection of sample introduction technique --- p.15 / Chapter 2.3.2 --- Recovery study of lead in standard reference material (SRM) in 1-decanol --- p.16 / Chapter 2.3.3 --- Study of suspension behavior of solvents with SRM --- p.16 / Chapter 2.3.4 --- Recovery study of lead in SRM in ethylene glycol --- p.17 / Chapter 2.3.5 --- Determination of lead in SRM by the developed method --- p.17 / Chapter 2.3.6 --- Determination of lead in SRM by the acid digestion method --- p.18 / Chapter 2.3.7 --- Application of the developed method on the analysis of real sample --- p.18 / Chapter 3. --- RESULTS AND DISCUSSION / Chapter 3.1 --- Choice of Solvents for Suspension of Air Particulates --- p.20 / Chapter 3.2 --- Sample Introduction Technique --- p.20 / Chapter 3.3 --- Recovery Study of lead in SRM in 1-Decanol --- p.22 / Chapter 3.3.1 --- Drying stage of the temperature program for analysis --- p.23 / Chapter 3.3.2 --- Effect of 1-decanol on the absorbance signal of the analyte --- p.24 / Chapter 3.3.3 --- Sample injection volume --- p.25 / Chapter 3.3.4 --- Design of temperature program for analysis --- p.25 / Chapter 3.4 --- Study of Suspension Behavior of Solvents --- p.27 / Chapter 3.5 --- Recovery Study of lead in SRM in Ethylene Glycol --- p.32 / Chapter 3.6 --- Evaluation of the Developed Method --- p.33 / Chapter 3.6.1 --- Determination of lead in SRM --- p.33 / Chapter 3.6.2 --- Application of non-linear standard addition method --- p.35 / Chapter 3.6.3 --- precision and accuracy of the developed method --- p.36 / Chapter 3.7 --- Recovery Study with the Acid Digestion Method --- p.36 / Chapter 3.8 --- Analysis of Real Sample by the Developed Method --- p.37 / Chapter 3.8.1 --- Principles of TEOM® on mass measurement --- p.37 / Chapter 3.8.2 --- Selection of filter media for air sampling --- p.37 / Chapter 3.8.3 --- Study of dislodging efficiency of air particulates from Teflon filter --- p.38 / Chapter 3.8.4 --- Comparison with the acid digestion method --- p.39 / Chapter 4. --- CONCLUSION --- p.40 / Chapter 5. --- REFERENCES --- p.41 / Chapter 6. --- APPENDIX --- p.46

Page generated in 0.0884 seconds