• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 333
  • 307
  • 188
  • 38
  • 30
  • 26
  • 18
  • 13
  • 12
  • 6
  • 6
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1075
  • 327
  • 171
  • 139
  • 96
  • 88
  • 75
  • 73
  • 71
  • 70
  • 69
  • 63
  • 61
  • 60
  • 58
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Estudo das repercussões hemodinâmicas através da cardioimpedância durante o uso de metilmetacrilato em cirurgia de artroplastia de quadril sob raquianestesia / Haemodynamic effects of methylmethacrilate on hip arthroplasty surgery under spinal anesthesia

Bonjorno Junior, José Carlos 30 August 2013 (has links)
O envelhecimento promove o aparecimento de doenças crônicodegenerativas, entre elas a osteoartrose. Artroplastia Total de Quadril (ATQ) tem sido procedimento comumente frequentemente com uso de cimento ósseo metilmetacrilato (MTC). Por outro lado, importantes alterações hemodinâmicas são descritas durante o procedimento de cimentação. A raquianestesia é um procedimento anestésico que produz menores efeitos hemodinâmicos e melhor analgesia pós-operatória em comparação a anestesia geral para a ATQ. Entretanto, especificamente neste procedimento cirúrgico tais alterações permanecem a ser investigadas. Buscamos avaliar os efeitos hemodinâmicos através da técnica de cardioimpedância em pacientes idosos submetidos à cirurgia de ATQ com o uso de MTC e raquianestesia. Utilizamos um estudo transversal, observacional, comparativo, inter-metodológico e com intervenção ativa. Método: Doze pacientes de ambos os sexos, > 65 anos, com indicação ortopédica para ATQ foram estudados. Os sujeitos receberam avaliação pré-anestésica e realizaram exames laboratoriais préoperatórios. Foram submetidos à cirurgia de ATQ com utilização de raquianestesia e implante de cimento de MTC. Os pacientes foram monitorados hemodinamicamente por meio da cardiografia de impedância, da saturação de oxigênio e pressão arterial, no intra-operatório, no momento acordado, durante a indução anestésica, na colocação do MTC e após este procedimento. Após a expansão volêmica observamos que houve aumento do DC quando comparado a raquianestesia, cimentação, inserção, redução da prótese e ao final da cirurgia (P<0,05). Tais resultados foram de certa forma, atenuados na presença de efedrina. No entanto, o VS sofreu alterações nos eventos supracitados na presença ou não da droga. Por outro lado, a FC, o IC e a RVS sofreu poucas alterações durante os eventos estudados. O DC, IC e o VS se correlacionaram com a massa corporal (r = 0,81, 0,60 e 0,67 respectivamente), o VS se correlacionou negativamente com a idade (r = -0.67), o IC se correlacionou negativamente com a classe funcional pela NYHA (r = -0,61) e o DC se correlacionou positivamente com a quantidade de efedrina administrada (r = 0,70). Conclusão: O procedimento cirúrgico de ATQ com MTC sob raquianestesia produz alterações hemodinâmicas e a cardioimpedância foi um instrumento útil para guiar os procedimentos e conduta do intraoperatório, configurando-se como uma técnica interessante para monitorização não invasiva. / Aging promotes the onset of chronic diseases, including osteoarthritis. Hip arthroplasty procedure has been commonly often the use of methylmethacrylate bone cement (MMA) has been used in the surgical procedure. On the other hand, significant hemodynamic changes are described in the cementation procedure. Spinal anesthesia is an anesthetic that produces less hemodynamic effects and better postoperative analgesia compared to general anesthesia for surgery arthroplasty. However, this particular surgical procedure (hip arthroplasty) such changes remain to be investigated. To evaluate the hemodynamic effects through cardioimpedance technique in elderly patients undergoing surgery for hip arthroplasty with the use of MMA for prosthetic hip and spinal. Twelve patients of both sexes, > 65 years, with orthopedic indication for hip arthroplasty were studied. The subjects received preanesthetic evaluation and underwent preoperative laboratory. From then underwent surgery for hip arthroplasty with use of spinal anesthesia and MMA cement. Patients were haemodynamically monitored by impedance cardiography, oxygen saturation and blood pressure intraoperative, when awake, during anesthesia induction, installing the MMA cement and after this procedure. After volume expansion, we observed that there was increase in CO when compared to spinal anesthesia, cementing, insertion, and reduction of the prosthesis at surgery (P<0.05). These results were somewhat attenuated in the presence of ephedrine. However, the SV underwent changes at aforementioned event on the presence or not of drugs. On the other hand, HR, CI and SVR has a few changed during the studied event. The CO, CI and the SV was correlated with body mass (r = 0.81, 0.60 and 0.67 respectively), SV was negatively correlated with age (r = -0.67), the CI was negatively correlated with NYHA functional class (r = -0.61) and CO was positively correlated with the amount of ephedrine administered (r = 0.70).Conclusion: The surgical procedure for hip arthroplasty under spinal anesthesia with MMA produces haemodynamic changes and cardioimpedance was a useful tool to guide the procedures and conduct of the intraoperative considering as interesting technique for noninvasive monitoring.
372

Telemetria de resposta neural: repercussões dos fatores etiológicos e no reconhecimento de fala após o implante coclear / Neural response telemetry: repercussions of etiological factors and speech recognition after cochlear implant

Guedes, Mariana Cardoso 04 December 2007 (has links)
INTRODUÇÃO: O Potencial de Ação Composto Evocado Eletricamente(PACEE) é a medida da atividade sincrônica das fibras neurais eliciadas pelo implante coclear. O potencial é registrado diretamente da cóclea, utilizando os eletrodos como geradores do estímulo e gravadores da resposta, procedimento denominado Telemetria de Resposta Neural (TRN). A análise das características da resposta neural pode ser útil no conhecimento sobre a funcionalidade do nervo auditivo e das estruturas neurais sobreviventes. A presença do PACEE pode estar, portanto, relacionada ao resíduo auditivo e influenciar no desempenho para processar os estímulos de fala. OBJETIVO: Identificar os possíveis fatores associados à ausência do PACEE na condição intra-operatória e avaliar a repercussão da ausência de resposta neural no desempenho em testes de reconhecimento de fala após 06 meses de uso contínuo do implante coclear. MÉTODOS: Clínico longitudinal retrospectivo. Participaram do estudo todos os indivíduos operados entre 2003 e 2006 com o implante N24 e cujos exames evidenciaram inserção completa e ausência de alterações nas impedâncias (n = 97). A ausência da resposta neural foi estabelecida quando não se encontrava registro de onda com reprodutibilidade em nenhuma das séries de otimização em todos os eletrodos pesquisados. Os processadores de fala foram ativados com parâmetros sugeridos pelo fabricante e os níveis de corrente determinados pelo método psicoacústico. Os testes de percepção de fala foram realizados após seis meses de uso contínuo e sem leitura orofacial ou apoio de gestos. Os indivíduos foram divididos em grupos de acordo com a presença do PACEE: Grupo \"TRN presente\" e Grupo \"TRN ausente\". A média dos resultados nos testes de reconhecimento de fala foi comparada entre os dois grupos utilizandose o teste não paramétrico U de Mann-Whitney, Teste exato de Fisher e teste do Quiquadrado. RESULTADOS: No Grupo TNR ausente a prevalência de surdez por meningite foi de 48% e no Grupo TNR presente de 13.9% (p < 0,001). O risco relativo para um indivíduo com surdez pós-meningite não apresentar respostas neurais para o estímulo elétrico no intra-operatório é 3.1 vezes maior do que o de um indivíduo com surdez por outras causas. A amostra foi estratificada por etiologia. Os resultados mostraram forte associação entre a ausência do PACEE e piores resultados em testes de reconhecimento de fala. OS resultadoS dos indivíduos em que o potencial foi ausente foram significantemente menor que a média dos indivíduos com PACEE presente (p = 0,002), independente da etiologia da surdez. CONCLUSÃO: A ausência do PACEE em usuários do implante coclear sugere pobre capacidade de despolarização e de condução neural diante da estimulação elétrica. A etiologia de surdez por meningite esteve associada à ausência do potencial e à piores resultados nos testes de reconhecimento de fala. Independentemente deste fator, a presença do potencial no momento intra-operatório esteve associada ao melhor desempenho para processar estímulos de fala, sugerindo um bom prognóstico com o dispositivo. / INTRODUCTION: The Electrically Evoked Compound Action Potential (ECAP) is the register of synchronic activity o neural fibers stimulated by Cochlear Implant. The potential is registered directly from the cochlea using the electrodes as stimulus probe and recorder. This procedure is called Neural Response Telemetry (NRT). The analysis of ECAP can be useful to understand the auditory system function and the surviving neural population. The ECAP presence could be, though, related to auditory residual and influence the ability to process the speech stimulus. Objective: to identify the factors associated to the absent NRT responses and the consequence repercussions for speech recognition after six months of cochlear implant use. METHODS: longitudinal retrospective clinical study. Selection criteria: individual who received N24 cochlear implant model between 2003 and 2006 and presented exams showing complete insertion of electrode array and normal impedances results (n = 97). The NRT absent responses were established when there was no reproducible register in any optimization series of all electrodes searched. The implant speech processors were mapped according to the manufactures default. The current levels were determined by psychoacoustic method. The speech perception battery tests were performed after six months of continual use of device, without lipreading or gestures. The individuals were divided in two groups: Group \"NRT present\" and Group \"NRT absent\". The average of speech perception tests results were compared between groups using the non-parametric Mann-Whitney U test, Exact Fisher\'s test and Chi-square test. RESULTS: In NRT absent group the prevalence of post meningitis hearing loss was 48% and in NRT present group of 13.9% (p < 0.001). The results showed strong association between the absence of ECAP and lower performance in speech recognition sentence test. In these results, the average of subjects whose potential were absent was significantly lower than the ones with ECAP present by intraoperative NRT, regardless the hearing loss etiology (p = 0.002). CONCLUSION: The ECAP absence in cochlear implant users suggests poor neural conduction under electrical stimulus. The post meningitis hearing loss was associated to the absence of potential and poor performance in the speech recognition tests. However, the presence of reproducible ECAP waves was associated to a better performance in processing speech stimulus and suggests a good prognosis with the cochlear implant device.
373

Comunicação pré-linguística e aquisição de linguagem em crianças com implante coclear / Prelinguistic communication and language aquisition in children with cochlear implants

Antonio, Fernanda de Lourdes 21 March 2014 (has links)
Os programas de implante coclear têm recebido crianças com diagnóstico de deficiência auditiva sensorioneural ou com Desordem do Espectro da Neuropatia Auditiva ambos de grau severo e/ou profundo, que não se beneficiam com os aparelhos de amplificação sonora individuais, em idade precoce. Essas crianças são candidatas a realizar a cirurgia de implante coclear ainda nos primeiros anos de vida, período considerado sensível para a plasticidade neuronal. Nesta perspectiva, é um desafio para os profissionais da área determinar precocemente quais crianças podem obter os maiores benefícios com o implante coclear, pois devido a pouca idade, são muito sutis as respostas apresentadas e o comportamento comunicativo ainda incipiente. Este estudo teve como objetivo investigar a correlação entre os comportamentos de comunicação pré-linguística em crianças candidatas à cirurgia de implante coclear e a aquisição da linguagem falada subsequente ao uso do dispositivo. Participaram 11 crianças com deficiência auditiva sensorioneural severo e/ou profundo bilateral pré-lingual e duas crianças com Desordem do Espectro da Neuropatia Auditiva bilateral de grau severo e/ou profundo. O estudo de caráter longitudinal prospectivo avaliou os participantes da pesquisa em quatro tempos distintos, sendo o primeiro tempo no momento pré-cirúrgico e os demais tempos após a ativação do implante coclear, ao longo do primeiro ano de uso do dispositivo. Os dados foram coletados em entrevistas com os pais dos participantes da pesquisa, análise dos registros dos prontuários e avaliação da comunicação pré-linguística e de linguagem falada de cada criança. Foram utilizados os instrumentos: Denver Developmental Screening Test II DDST II, MacArthur - Bates Communicative Development Inventory (CDI) Parte II Ações e Gestos, Escala de Compreensão e Expressão Reynell Developmental Language Scales RDLS e a Escala de avaliação de desenvolvimento familiar. Os instrumentos utilizados para avaliar as habilidades comunicativas e de linguagem falada guardaram correlação positiva entre eles. O grupo estudado apresentou evolução no comportamento pré-linguístico e na aquisição da linguagem falada ao longo do uso do implante coclear. Houve correlação positiva entre a comunicação pré-linguística e a aquisição da linguagem falada das crianças participantes do estudo. / The cochlear implants programs have received early age children diagnosed with bilateral prelingual severe-to-profound sensorineural hearing loss or bilateral prelingual severe-to-profound Auditory Neuropathy Spectrum Disorder, who didnt benefit from hearing aids. These children are candidates for cochlear implant surgery still in the early years of life, period considered sensitive for neuronal plasticity In this perspective, it is a challenge for professionals is to determine precociously which children can get the greatest benefits with the cochlear implant, because due to their young age, the answers provided are very subtle and the communicative behavior still very incipient. The purpose of this study was to investigate the relationship between prelinguistic communication behaviors in implantation candidates and subsequent language development after cochlear implant use. The study included 11 bilateral prelingual severe-to-profound sensorineural hearing loss children and two children with bilateral prelingual severe-to-profound Auditory Neuropathy Spectrum Disorder. The prospective longitudinal study assessed the children in preimplantation period and during the first year of use after cochlear implant activation, totaling four assessments for each participant. Datas were collected through interviews with the participants parents, analysis of medical records and assessment evaluation of prelinguistic communication and spoken language of each child. Denver Developmental Screening Test II DDST II, MacArthur-Bates Communicative Development Inventory - CDI, Reynell Developmental Language Scales RDLS and Family Involvement Pating were used. There was a positive correlations between instruments used to assess the prelinguistic communication behaviors and spoken language. The group investigated showed an increase in prelinguistic behavior and the acquisition of spoken language throughout the cochlear implant use. There was a positive correlation between prelinguistic communication and the acquisition of spoken language of the participating children in the study.
374

Modificação superficial de titânio para promoção de osteointegração / Titanium modification for the promotion of osteointegration

Aburaya, Jim Heiji 09 May 2011 (has links)
O titânio é considerado um biomaterial (material biocompatível) pela baixa reatividade e pela grande estabilidade da sua camada de óxido superficial. Pelas suas propriedades mecânicas ele é usualmente utilizado na fabricação de substitutos ósseos e implantes dentários. Visando contribuir para o desenvolvimento de novas superfícies osteointegráveis, neste trabalho foram estudadas duas superfícies de titânio modificadas com implantação iônica de P e BF2 com energia de 30 e 77keV, respectivamente. As superfícies foram submetidas a ensaios in vitro de cultura celular de células osteoblásticas (MG-63) e os resultados foram comparados com duas superfícies comerciais: poliestireno tratado para meio de cultura celular (PC) e titânio comum utilizado em implante dentário (TI). A atividade enzimática da fosfatase alcalina (FA) associadas à formação de biofilme mineralizado pelas células diferenciadas foram avaliadas. Concentrações de cálcio e fósforo no biofilme foram determinadas por espectroscopia de raios-X induzida por prótons, PIXE. Imagens superficiais com microscopia eletrônica de varredura serviram para verificar a homogeneidade e integridade dos biofilmes formados. Medidas de ângulo de contato foram realizadas para determinar o caráter hidrofílico das superfícies e do biofilme formado. As superfícies PC e TI se apresentaram hidrofílicas com formação de biofilme menos homogêneo que as apresentadas pelas superfícies PT e BFT, ambas hidrofóbicas. As concentrações de FA medidas no meio de cultura indicaram consumo maior que a secreção em PC e TI. Em PT e BFT foram observados acúmulos de FA no meio de cultura. Concentrações maiores de cálcio e fósforo foram observadas em PC e TI. Destas observações, as quatro superfícies podem ser consideradas biocompatíveis (não citotóxicas) pela formação de biofilme mineralizado e pelas medidas de atividade enzimática. / Titanium is considered a biomaterial (biocompatible material) due to its low reactivity and the great stability of its surface native oxide layer. With excellent mechanical properties, titanium is widely used as bone substitutes and dental implants. Aiming to contribute for the development of new surfaces to promote osteoblastic cell grow, two ion-beam-modified titanium samples were compared with two commercially available surfaces: polystyrene treated for cellular cultures (PC), and regular titanium used in dental implants (TI). The modified titanium samples were ion beam implanted with 30 and 77 keV phosphorous and BF2, respectively. All surfaces were employed for in vitro assays using cultures of osteoblastic cells (MG-63). The Phosphatase Alkaline Enzymatic Activity (ALP) was measured and associated with the mineralized bio-film formed by the differentiated cells. The concentration of calcium and phosphorus in the mineralized bio-film was measured by Proton Induced X-ray Emission, PIXE. Scanning Electron Microscope images were used to access the bio-film homogeneity and integrity. Contact angle measurements were used to characterize the wettability of the surfaces and the resulting bio-film. In spite of being more hydrophilic, the surfaces PC and TI formed of a less homogeneous bio-film than the PT and BFT surfaces, which were less hydrophilic. The ALP in the cell culture medium indicated greater consumption than secretion for PC and TI, while for PT and BFT accumulation of ALP was observed. Concentrations of calcium and phosphorus were greater for PC and TI samples. The four surfaces can be considered biocompatible (not cytotoxic) due to mineral bio-film formation and enzymatic activity measurements.
375

Resolução temporal auditiva de crianças usuárias de implante coclear / Auditory temporal resolution in children using cochlear implantation

Comerlatto Junior, Ademir Antonio 15 July 2011 (has links)
A resolução temporal auditiva é considerada uma das habilidades mais importantes para o processamento do sinal acústico ao longo do tempo. Ela permite identificar diferenças finas dos aspectos segmentais da fala, como a identificação de fonemas, e o início e o final de palavras em frases encadeadas. Crianças usuárias de Implante Coclear (IC) apresentam características próprias de decodificação e processamento do sinal da fala ao longo do tempo, realizada pelo IC. Diante do exposto, esta pesquisa teve por objetivo verificar o desempenho de crianças usuárias de IC em tarefas de resolução temporal. A amostra foi composta por 20 crianças usuárias de IC Nucleus 24/SPRINT (Grupo Experimental - GE) e 20 crianças sem alterações auditivas (Grupo Controle - GC). Foram aplicados o Random Gap Detection Test (RGDT) e o teste Gaps In Noise (GIN) para avaliar a habilidade de resolução temporal por meio de tarefas de detecção de gap. Os testes foram aplicados em campo livre e a 40dBNS. Os testes estatísticos utilizados para a análise dos dados foram o teste t de Student para dados independentes, e o teste de Mann Whitney e o Coeficiente de Correlação de Pearson. As crianças usuárias de IC obtiveram limiares de gap no RGDT de 74,13±51 ms e no teste GIN de 12,12±2,53 ms, sendo que apenas quatro das 20 crianças realizaram o teste GIN. Os limiares de gap do GC foram de 18,77±12,29 ms no RGDT e de 6,13±1,27 ms no teste GIN. A diferença entre os dois grupos foi estatisticamente significante. Além disso, houve diferença significativa na comparação dos resultados dos testes entre os sexos do GE, sendo o masculino melhor que o feminino. Não houve correlação entre a idade e os limiares de detecção de gap em ambos os grupos e, também, não houve significância entre o tempo de uso de IC e os resultados nos testes no GE. Mesmo avaliando a mesma habilidade auditiva, não houve correlação significante entre os resultados dos testes aplicados. Foi observado que crianças usuárias de IC apresentam os limiares de detecção de gap significativamente maiores que crianças sem alterações auditivas. / Auditory temporal resolution is considered one of the most important skills for acoustic signal processing along the time. It allows the identification of fine differences of speech segmental aspects, such as phonemes and the beginning and end of words in linked phrases. Children using a cochlear implant (CI) present specific characteristics of speech sign decoding and processing, along the time, performed by the CI. Thus, this research aimed at verifying the performance of children fitted with CIs, in temporal resolution tasks. The sample comprised 20 children using CI Nucleus 24/SPRINT (Experimental group - EG) and 20 children with no auditory alterations (Control Group - CG). The Random Gap Detection (RGDT) and Gaps In Noise (GIN) tests were applied to assess the temporal resolution skill through gap detection tests which were applied in free field and 40 dBSL. The statistical tests utilized for data analysis were Student´s t test, for independent data, Mann Whitney´s test and Pearson´s Correlation Coefficient. The children fitted with CIs achieved gap thresholds of 74,13±51 ms on the RGDT and 12,12±2,53 ms on the GIN test, the latter performed by only four out of the 20 children. Gap thresholds for the CG were 18,77±12,29 ms on the RGDT and 6,13±1,27 ms on the GIN test. The difference between the two groups was statistically significant. There was a significant difference in the comparison of the results of tests between the genders of EG, with males outdoing females. No correlation was seen between age and gap detection thresholds for both groups and there was no significance between the time of CI use and the results on the tests for the EG. Even assessing the same hearing skill, no significant correlation was seen between the results of the tests applied. Thus, it was observed that children fitted with cochlear implantation present gap detection thresholds significantly worse than those presented by normally hearing children.
376

Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysis

Martins, Renato 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
377

Laboratórios de bacteriologia da tuberculose / Tuberculosis bacteriological laboratories

Niero, Rinaldo 27 November 1975 (has links)
Este trabalho teve por objetivo contribuir para a implantação de uma Rede de Laboratórios de Bacteriologia da Tuberculose no Estado de São Paulo, visando a obter uma modificação efetiva da situação epidemiológica da tuberculose em nosso meio. O autor justifica inicialmente a bacteriologia como medida diagnóstica prioritária nos atuais programas de luta contra a doença. Apresenta, a seguir, um estudo preliminar sobre a implantação de Uma Rede de Laboratórios em uma das Divisões Regionais de Saúde do Estado de São Paulo, mostrando a sua viabilidade e exequibilidade. / The objective of this paper was to contribute to the implementation of a network of Tuberculosis Bacteriological Laboratories throughout the State of São Paulo (Brazil), designed to change effectively the epidemiological situation of tuberculosis among us. The author justifies bacteriology as the priority diagnostic procedure in the current programmes aiming the control of the disease, and presents a preliminary study regarding the implementation of a network of laboratories in a Regional Health Division of the State of São Paulo, showing its viability and operational possibility.
378

\"Resistência à perda de corte de instrumentos rotatórios de níquel-titânio submetidos à implantação iônica de nitrogênio\" / utting ability resistance in nickel-titanium instruments submitted to nitrogen ion implantation

Costa, Cristiane da 05 December 2006 (has links)
O presente estudo verificou o aumento da resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio, após tratamento de implantação iônica de nitrogênio. Para tal, foram utilizados vinte e um instrumentos da marca K3 ?ENDO, de n° 25.02, com 21 mm, divididos em dois grupos. O grupo 1 foi constituído por onze instrumentos submetidos à ação de uma câmara de implantação iônica de nitrogênio, servindo um deles como controle para a determinação da quantidade de íons implantados. O grupo 2 foi composto por dez instrumentos não submetidos ao processo de implantação iônica. Cada lima instrumentou 20 blocos de canais simulados 20.02 de 21 mm, previamente lavados em cuba ultra-sônica com detergente a 40°C por 10 minutos e depois com água bidestilada por mais 10 minutos. Os mesmos foram secos com jato de ar, voltaram para estufa a 40°C por 2 dias e finalmente pesados em balança analítica. Após cada instrumentação os blocos foram lavados em cuba ultra-sônica com detergente a 40°C por 20 minutos e pesados novamente. O ensaio de resistência à perda de corte foi realizado mediante a instrumentação de cada bloco com auxílio de um simulador de ação da instrumentação endodôntica, sendo a amplitude percorrida pelo contra-ângulo padronizada em 2,5 mm a cada penetração por 8 vezes atingindo um total de 2,0 cm para dentro do canal simulado, com força de penetração de 1,5 N. Quanto a resistência à perda de corte os resultados mostraram que os instrumentos implantados não apresentaram diferença estatisticamente significante em nível de 5 % (? = 0,5 %) até 20 usos. Porém, os instrumentos não implantados mostraram diferença estatisticamente significante (? = 0,5 %) entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Ao compararem-se instrumentos implantados e não implantados, observou-se que em 5 e 10 usos não houve diferença estatisticamente significante (p>5%). Já na comparação entre ambos com 15 e 20 usos a diferença foi estatisticamente significante (? = 0,5 %). Lícito foi concluir, portanto, que o processo de implantação de íons de nitrogênio manteve a resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio até 20 usos. Os instrumentos não implantados mostraram perda progressiva do poder de corte significativamente entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Comparando-se instrumentos implantados e não implantados, observou-se que até 10 usos ambos comportaram-se igualmente no que respeita à perda de corte. Já na comparação entre ambos com 15 e 20 usos a diferença foi significativa. / The present study investigated the cutting ability resistance in nickel-titanium instruments after nitrogen ion implantation treatment. Twenty-one instruments of K3 ?ENDO brand, number 20.02, with 21 mm, were divided in two groups. The group 1 submitted 11 instruments to nitrogen ion implantation chamber, while on served as positive control for the determination of the ion implantation quantity. In group 2, the 10 instruments were not submitted to ion implantation treatment. Each file instrumented 20 acrylic blocks 20.02 with 21 mm, previously washed in ultrasonic container with detergent in 40°C for 10 minutes and then with bidestiled water for 10 minutes. They were dried and put in a 40°C stove for 2 days and finally weighed in analytic balance. After instrumentation the blocks were washed for 20 minutes and weighed again. The usage essay was realized through the instrumentation of each block using an endodontic instrumentation simulated action, with a 2,5 mm standardized distance for 8 times, getting a total of 2,0 cm inside the simulated canal with a strong penetration of 1,5 N. The results showed that there was no statistical difference in cutting resistance of instruments treated with ionic implantation process until 20 uses. Although in the non treated instruments there was a gradual reduce in cutting ability resistance from 5 to 20 uses. The conclusion was that the nitrogen ion implantation process increases the cutting resistance of nickel-titanium instruments.
379

Qualidade de vida de crianças com implante coclear / Quality of life of children with cochlear implants

Silva, Joice de Moura 07 February 2018 (has links)
Diversos fatores influenciam sobre o desempenho das habilidades auditivas, da linguagem falada e da qualidade de vida de crianças com implante coclear. Investigar o impacto multidimensional da deficiência auditiva nas várias demandas da vida da criança pode auxiliar na identificação das variáveis de maior influência sobre os resultados desta população. O alcance dos maiores benefícios proporcionados pelo uso do dispositivo eletrônico depende da inserção efetiva na terapia fonoaudiológica especializada e dos investimentos na participação da família no processo de habilitação e reabilitação auditivas. Este estudo teve como objetivo avaliar a qualidade de vida de crianças com deficiência auditiva pré-lingual usuárias de implante coclear e analisar a correlação com os resultados da percepção auditiva da fala, com o desempenho da linguagem falada e com o grau de permeabilidade familiar no processo terapêutico. Participaram da pesquisa 30 crianças de ambos os sexos, com idade entre seis anos completos a 12 anos incompletos, usuárias de implante coclear e seus respectivos pais e/ou responsáveis legais. As crianças foram avaliadas quanto à percepção auditiva da fala, o desempenho da linguagem falada, a permeabilidade familiar e a qualidade de vida. A avaliação das habilidades auditivas mostrou correlação estatisticamente significante entre a escala de audição Categories Auditory Performance (CAP) e a Categoria de Linguagem. Na avaliação da linguagem falada não foram observados resultados estatisticamente significantes entre as variáveis do estudo. A permeabilidade familiar revelou correlações estatisticamente significantes com a CAP. Na perspectiva dos pais o IC melhorou a qualidade de vida em todos os domínios relacionados à criança e em um dos domínios referente à família. A subescala relações sociais apresentou maior escore entre os domínios. O aumento da idade cronológica impactou positivamente sobre os aspectos educacionais da qualidade de vida. Crianças com maiores categorias de audição apresentaram influência sobre a comunicação e a educação, a comunicação foi influenciada também pela categoria de linguagem. As habilidades de linguagem se correlacionaram com a autonomia das crianças e os pais mais permeáveis à reabilitação impactaram sobre a comunicação e a educação. Não foram encontradas correlações estatisticamente significantes entre a qualidade de vida e a idade na cirurgia e a idade auditiva. No entanto, a correlação negativa entre a idade na cirurgia e a qualidade de vida sugere que crianças implantadas mais cedo tendem a ter melhor qualidade de vida. Concluiuse, portanto, que a variável linguagem oral influenciou a qualidade de vida nos domínios comunicação e autonomia da criança. As variáveis desempenho auditivo e permeabilidade familiar influenciaram a qualidade de vida nos domínios comunicação e educação. A qualidade de vida no domínio educação também foi influenciada pela idade cronológica da criança. / Several factors have influence on the performance of hearing abilities, spoken language and quality of life of children with cochlear implants (CI). Investigating the multidimensional impact of hearing impairment on the various demands of the child\'s life can help identifying the variables that most influence on results of this population. The achievement of the greatest benefits provided by the use of the electronic device depends on effective insertion in specialized speech therapy and investments in family participation in the auditory habilitation and rehabilitation process. This study aimed to evaluate the quality of life of children with prelingual hearing loss who use cochlear implants and to analyze the correlation with the results of auditory perception of speech, the performance of spoken language and the degree of family permeability in the therapeutic process. Thirty children of both sexes, ranging from six complete years to 12 incomplete years, who use cochlear implants and their respective parents and/or legal guardians participated in the study. The children were evaluated for auditory perception of speech, performance of spoken language, familial permeability and quality of life. The evaluation of hearing abilities showed a statistically significant correlation between the auditory scale Categories Auditory Performance (CAP) and Language Category. In the evaluation of spoken language, no statistically significant results were observed among the studied variables. Familial permeability revealed statistically significant correlations with CAP. From the perspective of parents, CI improved quality of life in all domains related to the child and in one of the domains related to the family. The subscale social relations presented a higher score among the domains. The increase of chronological age had a positive impact on the educational aspects of quality of life. Children with higher hearing categories had an influence on communication and education, and communication was also influenced by language category. Language skills were correlated with the autonomy of children, and parents more permeable to rehabilitation impacted on communication and education. No statistically significant correlations were found between quality of life and age at surgery and hearing age. However, the negative correlation between age at surgery and quality of life suggests that early implanted children tend to have a better quality of life. Therefore, it was concluded that the variable oral language influenced the quality of life in the domains communication and autonomy of the child. The variables auditory performance and familial permeability influenced on quality of life in communication and education domains. Quality of life in the education domain was also influenced by the chronological age of the child.
380

Resistência à corrosão do aço inoxidável AISI 304 com implantação de íons de cobre

Canabarro, Felipe Ariel Furlan January 2018 (has links)
O efeito bactericida de íons cobre é bem conhecido; no entanto a atividade inibitória depende diretamente da concentração desses íons no material base. Contudo, essa concentração deve ser controlada, pois o excesso destes íons pode ser tóxico e além disso, a implantação de cobre pode comprometer a resistência a corrosão do substrato metálico. A propriedade bactericida é desejável para aplicação em ligas metálicas empregadas em diversos setores, na assepsia de materiais que tenham contato direto com subprodutos que necessitam alta pureza e com baixíssimos índices de contaminação. O aço inoxidável austenítico AISI 304 é amplamente utilizado devido às suas propriedades mecânicas e de resistência à corrosão. Considerando isso, o aço AISI 304 é o foco do presente estudo, mesclando as características anticorrosivas naturais com a assepsia oligodinâmica proveniente da dopagem com íons de cobre. Nesse sentido, avaliou a resistência à corrosão do aço inoxidável AISI 304 com diferentes doses de cobre implantado (1015 íons.cm-2 e 1016 íons.cm-2) por monitoramento do potencial de circuito aberto e voltametria cíclica em uma solução eletrolítica de NaCl 3,5 % em peso. Através de simulações computacionais, previu-se que nos parâmetros escolhidos, a profundidade de implantação dos íons no substrato atingiu até 40 nm da superfície, com uma concentração de pico, maior teor de cobre, na profundidade de 12 nm. As amostras com doses de 1015 íons.cm-2 de cobre apresentaram o potencial de pites semelhante ao aço inoxidável austenítico AISI 304 sem implantação de Cu. Na análise de EDS observou-se que as áreas que não sofreram corrosão, apresentaram melhor distribuição dos elementos de liga e do cobre implantado em comparação com as regiões com maior incidência de pites. A maior intensidade de pites foi encontrada para a amostra com maior dose de cobre implantado (1016 íons.cm-2 de cobre). / The bactericidal effect of copper ions is well known; however, the inhibitory activity depends directly on the concentration of these ions in the base material. However, this concentration should be controlled because the excess of these ions can be toxic and the implantation of copper may compromise the corrosion resistance of the metal substrate. The bactericidal property is desirable for application in metal alloys used in the several sectors, in the asepsis of materials that have direct contact with by-products that require high purity and with very low contamination rates. The AISI 304 austenitic stainless steel is widely used because of its mechanical properties and corrosion resistance. Considering this, the AISI 304 is the focus of the present study, mixing the natural anticorrosive characteristics with the oligodynamic aseptic from the copper ions doping. The corrosion resistance of AISI 304 stainless steel with different doses of implanted copper (1015 ions.cm-2 and 1016 ions.cm-2) was evaluated by monitoring the open circuit potential and cyclic voltammetry in an electrolytic solution of NaCl 3,5% by weight. Through computational simulations, it was predicted that in the chosen parameters, the implantation depth of the ions in the substrate reached up to 40 nm from the surface, with a peak concentration, higher copper content, at the depth of 12 nm. The samples with doses of 1015 ions.cm-2 of copper had the pit potential similar to the austenitic stainless steel AISI 304 without implantation of Cu. In EDS analysis, it was observed that the areas that did not undergo corrosion had better distribution of the alloying elements and of the implanted copper compared to the regions with a higher incidence of pitting. The highest pitting intensity was found for the sample with the highest dose of implanted copper (1016 ions.cm-2 copper).

Page generated in 0.0387 seconds