• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 2
  • Tagged with
  • 54
  • 54
  • 45
  • 36
  • 36
  • 19
  • 16
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

[en] ANALYSIS OF THE APPLICATION OF PVDF IN PIPES FOR MEASURING WATER FLOW RATE / [pt] ANÁLISE DA APLICAÇÃO DO PVDF EM TUBULAÇÕES PARA MEDIÇÃO DE VAZÃO DE ÁGUA

KHRISSY ARACELLY REIS MEDEIROS 09 January 2019 (has links)
[pt] As propriedades mecânicas, reológicas e elétricas do polímero poli (fluoreto de vinilideno) – PVDF – têm sido extensivamente estudadas, mas em particular é sua propriedade piezoelétrica que motiva a maior parte dos trabalhos, visto que a piezoeletricidade ocorre em poucos materiais e é mais intensa no PVDF em relação a outros polímeros. O fator chave que define a faixa de aplicação de polímeros piezoelétricos é a sua utilização na concepção de transdutores, sensores e atuadores. Neste sentido, a presente pesquisa analisa a aplicabilidade do polímero PVDF em tubulações para medição de vazão de água, empregando como método de medição de vazão a técnica de Flow Induced Vibration (FIV), considerando as propriedades piezoelétricas peculiares do polimorfo PVDF-B(beta). De modo geral, a FIV é um fenômeno que causa instabilidade das tubulações que transportam fluidos, tido como um problema operacional que ocorre em muitas plantas industriais. No entanto, este fenômeno passou a ser investigado como uma técnica de medição de vazão, a qual considera que a massa de um fluido pode ser indiretamente medida, medindo-se a aceleração que ela transmite para outro corpo, de modo que o desvio padrão do sinal da vibração medida aumenta com a vazão, sendo mais bem ajustado por um polinômio de segundo grau. A metodologia de trabalho consistiu em caracterizar o material espectroscopicamente, por meio de técnicas de Espectroscopia no Infravermelho com Transformada de Fourier (FTIR) e Difração de Raios-X (DRX); eletromecanicamente, em um shaker mecânico no Laboratório de Sensores a Fibras Ópticas do Departamento de Engenharia Mecânica da PUC-Rio; e finalmente em um circuito hidráulico de testes do Laboratório de Escoamento de Fluidos do Departamento de Engenharia Mecânica da PUC-Rio. Ensaios foram realizados de forma a identificar os níveis de tensões elétricas geradas pela vibração oriunda da passagem da água no tubo de PVDF. Visando à comparação com os sinais de vibração, foram realizadas medições simultâneas com acelerômetros e um filme de PVDF. Para medir a deformação no tubo adotaram-se sensores de Rede de Bragg. Os resultados dos ensaios de FIV permitiram concluir que o desvio padrão do sinal da tensão medida pelo tubo de PVDF é proporcional à vazão. No entanto, algumas variáveis precisaram ser controladas. As incertezas associadas à medição de vazão pelo tubo mostraram uma considerável redução nos níveis mais altos de vazão. Por outro lado, nos níveis mais baixos de vazão observou-se uma instabilidade muito grande, possivelmente devido ao processo de acomodação mecânica inicial do tubo. Apesar disso, uma forte relação entre o sinal gerado pelo tubo de PVDF e a vazão que induziu esta vibração permitiu que a aplicabilidade do tubo de PVDF como medidor de vazão de água fosse comprovada. / [en] The mechanical, rheological and electrical properties of polymer poly (vinylidene fluoride) - PVDF - have been extensively studied, but in particular it is its piezoelectric property that motivates most of the works, since the piezoelectricity occurs in few materials and is more intense in PVDF relative to other polymers. The key factor that defines the range of applications of piezoelectric polymers is their use in the conception of transducers, sensors and actuators. In this sense, the present research analyzes the applicability of the PVDF polymer in pipes for the measurement of water flow rate, using as flow measurement method the Flow Induced Vibration (FIV) technique, considering the peculiar piezoelectric properties of the polymorph PVDF-B(beta). In general, the FIV is a phenomenon that causes instability of the pipes that transport fluids, considered as an operational problem that occurs in many industrial plants. However, this phenomenon has been investigated as a flow rate measurement technique, which considers that the mass of a fluid can be indirectly measured by measuring the acceleration it transmits to another body, so that the standard deviation of the signal of the measured vibration increases with the flow rate, being better adjusted by a second degree polynomial. The work methodology consisted in characterizing the material spectroscopically, using Fourier Transform Infrared Spectroscopy (FTIR) and X-Ray Diffraction (XRD) techniques; electromechanically, in a mechanical shaker at the Optical Fiber Sensors Laboratory of the Mechanical Engineering Department of PUC-Rio; and finally in a test hydraulic circuit of the Laboratory of Fluid Flow of the Department of Mechanical Engineering of PUC-Rio. Tests were carried out in order to identify the levels of electrical voltages generated by the vibration caused by the passage of water in the PVDF tube. In order to compare the vibration signals, simultaneous measurements were made with accelerometers and a PVDF film. To measure the deformation in the tube, Bragg Network sensors were adopted. The results of the FIV tests allowed concluding that the standard deviation of the voltage signal measured by the PVDF tube is proportional to the flow rate. However, some variables had to be controlled. The uncertainties associated with flow rate measurement by tube showed a considerable reduction in the higher flow rates. On the other hand, in the lower levels of flow rate a very great instability was observed, possibly due to the process of initial mechanical accommodation of the tube. Nevertheless, a strong relationship between the signal generated by the PVDF tube and the flow rate that induced this vibration allowed that the applicability of the PVDF tube as a water flow meter was proved.
12

[en] USE OF ULTRASONIC FLOW METERS FOR TRANSFER CUSTODY OF NATURAL GAS / [pt] UTILIZAÇÃO DE MEDIDORES ULTRASSÔNICOS PARA MEDIÇÃO FISCAL DE VAZÃO DE GÁS NATURAL

CLAUDINEI MARCHETI JUNIOR 09 February 2018 (has links)
[pt] A medição de gás natural pelo princípio do ultrassom se mostra competitiva, sob diversos aspectos, quando comparada com medidores deprimogênios, em especial a placa de orifício. O presente trabalho apresenta uma avaliação técnica da utilização de medidores ultrassônicos de múltiplos feixes em sistemas fiscais e para transferência de custódia. Uma avaliação de conformidade em relação às principais normas internacionais relativas à medição de vazão de gás natural pelo princípio do ultrassom é realizada através de dados coletados, para um mesmo medidor, durante sua calibração em laboratório e durante sua operação no campo. Apresenta também uma análise das ferramentas de diagnósticos disponíveis pelo medidor, comparando os resultados obtidos em laboratório e no campo. Foi proposta uma metodologia para a determinação das estimativas de incerteza da medição da vazão instantânea e do volume de gás em determinado intervalo de tempo. As avaliações de conformidade com as normas e as análises das ferramentas de diagnósticos disponíveis mostram que a utilização de medidores ultrassônicos na medição fiscal de gás natural é tecnicamente viável; além disto, considerando um intervalo de tempo conveniente para a totalização dos volumes medidos, a incerteza de medição pode ser bastante reduzida. / [en] The measurement of natural gas by the ultrasonic principle is shown to be competitive in several aspects when compared with orifice plate meters. This paper presents a technical evaluation of the use of multipath ultrasonic meters for custody transfer. The analysis of the meter performance matching with the requirements of principal international standards for measuring of natural gas flowrate by the ultrasonic principle is made using data collected for the same meter during the calibration in laboratory and during operation in the field. It also presents an analysis of the diagnostic tools available by the meter, comparing the results obtained in laboratory and field. A methodology for determining estimates of measurement uncertainty of flow rate and totalize gas in a given time interval is proposed. Evaluations of compliance with the standards and the analysis of the diagnostic tools available show that the use of ultrasonic meters in the fiscal measurement of natural gas is technically feasible, and that, by varying the time for measuring volumes, the uncertainty of measurement can be quite reduced.
13

[en] FLOW MEASUREMENT OF OIL AND NATURAL GÁS IN BRAZIL: MANAGEMENT AND REGULATION / [pt] MEDIÇÃO DE PETRÓLEO E GÁS NATURAL: ANÁLISE CRÍTICA DOS ASPECTOS DE GESTÃO METROLÓGICA E DE REGULAÇÃO NO BRASIL

JOSE CARLOS NOGUEIRA SIQUEIRA 10 June 2010 (has links)
[pt] Dadas as expectativas de grandes descobertas de petróleo no Brasil (que incluem o pré-sal) a recente legislação que regulamenta a medição de vazão de petróleo e gás natural no país - e que faz intenso uso de infra-estrutura laboratorial- está sendo revista. A presente pesquisa de mestrado tem por objetivo desenvolver uma análise crítica envolvendo aspectos técnicos e legais do Regulamento Técnico de Medição de Petróleo e Gás Natural (RTM) instituído pela Portaria Conjunta ANP-INMETRO 001/2000. A motivação institucional para o desenvolvimento da pesquisa origina-se do interesse da Petrobrás em colaborar para o avanço do conhecimento relacionado às tecnologias e aos aspectos legais da medição. E, também, da experiência do autor no setor de contratos da Petrobrás cuja problemática da medição da produção de petróleo e gás natural está sendo revista. O trabalho foi desenvolvido no contexto de recentes descobertas de campos gigantes em águas profundas e ultra-profundas. Após o anúncio dessas novas reservas, agentes econômicos têm pressionado a Agência Nacional de Petróleo (ANP) para revisar e reavaliar o Regulamento Técnico de Medição instituído pela Portaria Conjunta ANP-INMETRO 001/2000. O trabalho seguiu os seguintes preceitos metodológicos (i) estudo de legislações aplicáveis à medição de petróleo e gás de países industrializados; (ii) entrevista com especialistas do INMETRO, ANP, Petrobrás (CENPES, divisão de contratos) e com dirigentes técnicos dos principais laboratórios de medição de vazão de petróleo e gás ern operação no país (IPT, CT-PETRO, CT-GÁS, CONAUT, METROVAL, EMERSON) para avaliar pontos críticos da Portaria Conjunta ANP-INMETRO; (iii) análise da consistência e adequação técnica e jurídica da referida Portaria e (iv) identificar novas demandas e necessidades da indústria de petróleo e gás natural no país. Dentre os resultados da pesquisa destacam-se a identificação e a classificação de aspectos técnicos e legais da Portaria ANP-INMETRO 001/2000 que carecem de revisão. Como conclusão, o trabalho sugere a adaptação da legislação vigente para fazer frente a novos desafios impostos ao setor. / [en] Because of the expectation for further massive oil fmdings in Brazil`s continen tal platform-including the presalt play-, the existing laws which regnlate the oil and natural gás measurement involving intensive use of laboratory infras-tructure are being reviewed. The objective of this M.Sc.`s research project is to assess legal and technical aspects of the Joint Administrative Rule ANP-INMETRO / 001/2000, specifically the Technical Regulation of Oil and Natural Gás Measurement (RTM).The inotivation of this work emerged frorn the anthors own experience at the legal department of Petrobras dealing with custody transfer contracts where measurements of the production of oiland natural gás play a key economic role. Following the announcements of the ultra-deep giant fields, the work was developed in an economic context where agents are pressing the Brazilian Petroleum Agency (ANP) the national oil and gás regulator to review and reassess the applicable Technical Regulation of Measurement (RMO). The project followed four methodological precepts (i) study of applicable laws to the flow measuremeut of oil and gás in developed countries; (ii) interview with experts of INMETRO, ANP, PETOBRAS (CENPES, division of contracts) and technical managers of themain laboratories involved in flow measurements (IPT, CT-PETRO, CTGAS, CONAUT, METROVAL, EMERSON) to ascertain criticai points in the Joint Administrative Rule ANP-INMETRO; (iii) analysis of consistency of legal and technical aspects of the Administrative Rule and (iv) identify new demands and needs of the oil and gás industry in the country. As the main result, the work identified and characterized technical and legal aspects of the legislation related to oil and gás flow measnrements to help reformulate and update the Administrative Rule, ANP-INMETRO 001/2000. In conclusion, the oil and gás legislation conccrning the Technical Regulation and Measurement should be adapted to new exploration challenges.
14

[en] METROLOGICAL ANALYSIS ON THE ECONOMICAL IMPACT OF REAL TIME FLUID PROPERTY CORRECTION IN NATURAL GAS FLOW MEASUREMENT ON THE TRANSPORTATION PIPELINES / [pt] MEDIÇÃO DE VAZÃO DE GÁS NATURAL POR PLACA DE ORIFÍCIO. AVALIAÇÃO METROLÓGICA E IMPACTOS ECONÔMICOS

LILIAN ALVES MARTINS 03 March 2006 (has links)
[pt] A presente dissertação de mestrado faz uma análise metrológica focada na medição da vazão e totalização do volume de gás natural através de placa de orifício. O trabalho considera no cômputo da vazão a determinação das propriedades físico-químicas do combustível e a utilização desses parâmetros na medição de volume de gás natural. O trabalho também considera aspectos relativos à aquisição eletrônica de outras variáveis como pressão, temperatura e pressão diferencial, comumente amostradas em uma estação de medição de vazão de gás natural por placa de orifício. Não obstante, o estudo reflete uma permanente preocupação da Petrobras em garantir a confiabilidade de suas medições e encontra sua motivação em mostrar que metrologia constitui-se, de fato, em importante insumo para avaliação de impacto técnico e econômico. O estudo considera três alternativas para aplicação da composição química do gás natural no cálculo da vazão de gás natural em cada um dos pontos de transferência de custódia da malha de gasodutos da Petrobras. Cada uma das soluções técnicas está associada a investimentos em instalação, operação e manutenção de complexos equipamentos, criando inusitadas oportunidades para análise da confiabilidade metrológica capazes de produzir impacto econômico, cabendo aqui lembrar que incertezas e erros associados ao processo de medição não necessariamente são reduzidos com o aumento dos investimentos em tecnologia e instrumentação. O estudo dessas questões torna-se ainda mais atraente quando se considera que a malha de gasodutos da Petrobras distribuem cerca de 35 dos 45 milhões de m3 de gás natural consumidos diariamente no Brasil. Cabe ainda salientar a relevância deste estudo no âmbito das melhorias estruturais propostas, uma vez que a presente dissertação mostra que é possível garantir controle metrológico a um custo justificado, agregando benefícios que não se limitam à malha de gasodutos existente. / [en] This study presents a metrological analysis focused on the natural gas flow and volume measurement by orifice plate measurement systems. It takes into account the determination of chemical and physical properties and the application of these parameters in the flow and volume measurement. The study also considers aspects related to the electronic sampling of other process information such as pressure, temperature and differential pressure. Nevertheless, it demonstrates that metrology is, in fact, an important input of economical and technical analysis and shows a permanent concern of Petrobras: to guarantee measurement reliability. The dissertation presents three alternatives to the application of the natural gas composition in the computation of flow and volume measurement. When measuring natural gas flow and volume at the custody transfer points, the invoicing process begins to take place. Therefore, each one of the alternatives is associated to benefits, such as reduction of uncertainty, and costs and investments in equipments. It`s worthy to mention that it creates interesting opportunities to develop metrological analysis capable of generate economical impact. This study is even more attractive when referring to a 50 million cubic meters scenario, the Brazilian daily natural gas volume consumption. The relevance of this study is to show that is possible guarantee metrological control to a justified cost.
15

[en] COMPARISON OF AGENT AND OBJECT ORIENTED PROJECTS USING THE GEORISC PLATFORM / [pt] COMPARAÇÃO DE PROJETO BASEADO EM AGENTES E ORIENTAÇÃO A OBJETOS NA PLATAFORMA GEORISC

SERGIO LUIZ RUIVACE CERQUEIRA 08 September 2011 (has links)
[pt] Diversas tecnologias de implementação de software são discutidas na literatura. Duas dessas tecnologias são a orientação a objetos, que se encontra consolidada, e a orientação a agentes, que vem sendo objeto de muitos estudos e experimentos. Esses estudos indicam a orientação a agentes como muito promissora e como uma evolução da orientação a objetos. No entanto, há poucos trabalhos comparando essas duas técnicas e os poucos trabalhos se baseiam em comparações ideológicas e qualitativas. Essa dissertação tem por objetivo desenvolver e avaliar modos sistemáticos de avaliação de duas arquiteturas de implementação de sistemas. As duas tecnologias apresentadas foram comparadas e foi determinado se a utilização de uma tecnologia trouxe benefícios, desvantagens ou foi indiferente face à outra. A comparação foi realizada tomando por base um problema real, ou seja, foram criadas duas implementações que solucionam o problema de modo similar cada uma usando uma tecnologia. Para o desenvolvimento desse trabalho foi criado um plano de medição com base na técnica Goal Question Metric. O plano de medição foi aplicado às duas implementações e resultados obtidos foram avaliados definindo os benefícios de cada técnica. Por fim, foi feita uma crítica da utilização do modelo GQM em um projeto real. / [en] There are several software development technologies currently in the literature. Two such technologies are object orientation, which is consolidated, and agent orientation, which has been the subject of many studies and experiments. These studies indicate the agent orientation as very promising and an evolution of object orientation. However, there is only a few studies comparing these two techniques and these studies have been based on ideological and qualitative comparisons. This dissertation aims to develop and evaluate methods of systematic evaluation of two architectures for implementing systems. The two technologies presented were compared and determined whether the use of technology has brought benefits, disadvantages or was indifferent to the other. The comparison was performed based on taking a real problem; in other words, two implementations have been created that address the problem similarly each using a technology. To develop this work, it was created a measurement plan based on the technique Goal Question Metric. The measurement plan was applied to both implementations and results were evaluated by defining the benefits of each technique. Finally was done a discussion about the use of the GQM model in a real project.
16

[en] STUDY OF THE WHITE TARIFF FOR HOUSEHOLD CONSUMERS BY MEASUREMENT OF ENERGY CONSUMPTION AND BY THE SURVEY OF POSSESSION AND HABITS / [pt] ESTUDO DA TARIFA BRANCA PARA A CLASSE RESIDENCIAL PELA MEDIÇÃO DE CONSUMO DE ENERGIA E DE PESQUISA DE POSSES E HÁBITOS

MARCOS ALEXANDRE LIMBERGER 26 September 2016 (has links)
[pt] Esta dissertação de mestrado teve por objetivo demonstrar, por meio da análise de medições inteligentes e de pesquisas de posse de equipamentos e hábitos de uso (PPHs), quais os perfis de consumidores residenciais que poderão se beneficiar caso adotem a tarifa branca, reduzindo os custos de suas faturas de energia sem comprometer drasticamente seu conforto e tornando seu consumo de energia mais sustentável. Foi realizado um estudo de caso na área de concessão da distribuidora Coelce. A motivação para realização desse estudo de caso resultou do fato de ser um tema novo para o consumidor residencial brasileiro, com escassa literatura nacional, e que será objeto de diversos questionamentos, exigindo uma postura mais ativa do consumidor no sentindo de gerenciar seu consumo e reduzir os desperdícios, tornando mais complexa as relações consumidor versus concessionária e consumo de energia. A metodologia se utiliza do tratamento de dados e análises estatísticas de medições provenientes de medidores eletrônicos providos de memória de massa que registram leituras de consumo a cada 15 minutos em alguns equipamentos e no ramal de entrada. Utilizaram-se informações de PPHs como apoio às análises. Os resultados permitiram identificar quais as faixas de consumo que mais se beneficiariam da adesão à tarifa branca, quais equipamentos podem ter seu consumo deslocado e quais ações de gerenciamento de carga podem vir a ser adotadas. Concluiu-se que 55 por cento dos consumidores seriam beneficiados pela tarifa branca – outros 25 por cento teriam potencial –, obtendo descontos de 1,62 por cento a 14,60 por cento em suas faturas de energia. / [en] This thesis aimed to demonstrate, through the analysis of intelligent measurement and survey of possession and habits (PPHs), which profiles of residential consumers that will be able to benefit if they adopt the white-tariff, cutting down the costs of their energy bills without quite compromising your comfort, and making your consumption of energy more sustainable. A case study was done conducted in the concession area of the Coelce power utility. The motivation for conducting this case study resulted from the fact that it is a new theme for Brazilian household consumers, with little national literature, and will be subject to several questions, requiring a more active stance of the consumer to manage their consumption and reduce the losses, becoming more complex the relationship as consumer versus utility and energy consumption. The methodology makes use of data processing and statistical analysis of measurements from smart meters equipped with mass memory which record consumption readings every 15 minutes in some equipment and the input extension of energy. PPHs information were used as supporting analyzes. The results showed which are the ranges of consumption that would most benefit from joining the white-tariff, which equipment may have shifted their energy consumption and what actions of load management can be adopted. The conclusion was reached that 55 percent of consumers would be benefited by the white tariff – another 25 percent had potential – getting discounts of 1.62 percent to 14.60 percent on their energy bills.
17

[en] METROLOGICAL RELIABILITY OF HIGH FREQUENCY SURGICAL EQUIPMENT / [pt] CONFIABILIDADE METROLÓGICA DE UNIDADES ELETROCIRÚRGICAS DE ALTA FREQÜÊNCIA

ROSARIO DEL PILAR ALVA PALOMARES 28 March 2006 (has links)
[pt] A garantia da confiabilidade metrológica de equipamentos médicohospitalares, apesar de essencial para garantir a obtenção do efeito desejado e evitar efeitos adversos, em geral não é realizada durante o período de uso (pós-comercialização). Dentre as principais causas possíveis desta realidade se encontra a falta de informação por parte dos profissionais usuários quanto aos riscos, ou seja, a reduzida cultura metrológica no ambiente da saúde. A partir da identificação de alguns pontos vulneráveis e de graves repercussões na utilização inadequada de bisturis eletrônicos, esta dissertação avaliou parâmetros para a confiabilidade metrológica destes equipamentos, tanto em nível técnico e normativo, quanto em termos da utilização em ambientes hospitalar.Foi realizada uma busca e identificação da normalização nacional, e avaliada a abrangência das normas para garantir de forma completa a utilização dos equipamentos. Os trabalhos práticos para a avaliação metrológica das unidades eletrocirúrgicas foram realizados em três hospitais. Os resultados obtidos auxiliaram na avaliação da confiabilidade metrológica das unidades eletrocirúrgicas em uso, apontando para a necessidade não só de um controle metrológico periódico, como também da inserção de parâmetros de avaliação que não constam na norma aplicável ao equipamento em estudo. Parte desta dissertação foi financiada, através do Convênio referência FINEP n° 22.01.0692.00, pelo Programa Tecnologia Industrial Básica e Serviços Tecnológicos para a Inovação e Competitividade MCT/FINEP/FNDCT/Fundo Verde Amarelo, um programa cooperativo universidade-empresa. / [en] The metrological reliability of electromedical equipment, although essential in order to guarantee the desired effects and to avoid adverse effects, is often not verified after the equipment is sold and being used (post-sale period). This is partially due to the fact that, usually, health-care takers that use the equipment are unaware of the risks involved, in other words, there is a low metrological culture in the healthcare environment. In this dissertation, vulnerable aspects regarding the inadequate use of high frequency surgical equipment, also known as electrosurgical unit (ESU), were identified, and their consequences evaluated. Based on these results, technical and standard parameters important for the metrological reliability of ESUs, were evaluated. This dissertation also includes a detailed bibliographical research of basic principles, technical specifications, and international procedures that guarantee the metrological reliability of electrosurgical units. The scope of national standards was evaluated in order to guarantee the correct use of all of the ESU´s functions and modes. Experimental data for the metrological evaluation of the EUSs were collected in three (3) hospitals, one (1) private and two (2) public. The results are helpful for evaluating their metrological reliability, and indicate that not only that there is a need for a periodical metrological evaluation, but also that other parameters should be included in existing standards. Part of this dissertation was financed by the Convênio referência FINEP n° 22.01.0692.00 of the Programa Tecnologia Industrial Básica e Serviços Tecnológicos para a Inovação e Competitividade MCT/FINEP/FNDCT/Fundo Verde Amarelo, a universitycompany cooperative program.
18

[en] CALIBRATING THE ELECTRICAL APPLIANCES ONWERSHIP SURVEYS THROUGH ELECTRONICS DEVICES MEASUREMENTS OF ENDUSES CONSUMPTION / [pt] CALIBRAÇÃO DE RESULTADOS DE PESQUISAS DE POSSES E HÁBITOS PELA MEDIÇÃO ELETRÔNICA DE CONSUMO DE ELETRODOMÉSTICOS

JOSE AGUINALDO MENDES PINHO 03 September 2013 (has links)
[pt] Nesta dissertação, é apresentado um procedimento estatístico para a estimação de perfis de curvas de carga por aparelhos para consumidores residenciais atendidos na BT (Baixa Tensão). O modelo desenvolvido utiliza informações de duas fontes distintas: PPHs (Pesquisas de Posses e Hábitos de Aparelhos Elétricos) e Medições de consumo com medidores eletrônicos com memória de massa que gravam leituras de consumo por aparelhos a cada 15 minutos. Através das PPHs desenvolvidas por Procel/Eletrobrás em 1996, obtêm-se um perfil aproximado da curva de carga do domicilio por aparelho. Entretanto, esta curva tende a ser imprecisa, pois é obtida por declarações de uso dos aparelhos. Para reduzir esta imprecisão, foi montado um experimento onde uma sub-amostra de domicílios auditados pelas PPHs, teve os principais aparelhos da residência medidos por medidores eletrônicos em intervalos de 15 minutos. A partir das curvas de utilização destes aparelhos, obtidas pelos dois procedimentos, utilizou-se um modelo estatístico de regressão linear para estimar coeficientes de ajustes para correção das curvas declaradas para cada hora do dia, para os principais eletrodomésticos do domicílio. Os resultados foram aplicados a duas distribuidoras do grupo ENDESA: AMPLA e COELCE. / [en] In this thesis, it is presented a statistical based model that allows the estimation of the load shape curve for appliances (end uses) for residential consumers that belong to low voltage group (BT clients), using information from two sources: PPHs (Energy Audit on Ownership and Usage of Electrical Appliances) and household measurements through specific devices that provide not only the total consumption (15 minute intervals) as well as the breakdown of this consumption for each device (end use) existing in the household. Through energy audits (PPHs) developed by Procel/Eletrobrás in 1996, one has a rough idea of the load shape curves by appliance. However, the curves obtained this way tend to be rather imprecise, as they are obtained by the consumer information of usage of the equipments on the surveys, which tend to be rather vague. In order to reduce such imprecision, an experiment was set where a subsample of the original survey sample is selected and the main appliances consumption measured by electronic meters at intervals of 15 minutes. The end use load shape obtained by these meters are then compared with the corresponding curve obtained by usage declaration. Using the linear regression model, the correction coefficients of the declarations are obtained for each hour of the day, for the main appliances. The results were applied to two distribution utilities of the ENDESA group: AMPLA and COELCE.
19

[en] REMOTE MEASUREMENT AS STRATEGY TO MONITOR STATIONARY BATTERIES: CASE STUDY IN AN ELETRIC POWER SUBSTATION / [pt] MEDIÇÃO REMOTA COMO ESTRATÉGIA DE MONITORAMENTO DE BATERIAS ESTACIONÁRIAS: ESTUDO DE CASO EM UMA SUBESTAÇÃO DE ENERGIA ELÉTRICA

GILCINEA RANGEL PESENTI 01 October 2013 (has links)
[pt] A presente dissertação tem por objetivo geral validar em condições reais de operação, a técnica (desenvolvida em ambiente laboratorial) de monitoramento remoto de baterias estacionárias e como objetivos específicos identificar as limitações das tecnologias convencionais de monitoramento de baterias estacionárias, avaliar a confiabilidade do método de monitoramento remoto proposto e justificar a alternativa tecnológica proposta à luz do impacto econômico que dela decorrem. O desenvolvimento deste tema de dissertação de mestrado foi motivado pelas contribuições que poderá produzir para a Light e demais empresas dos setores elétricos, óleo e gás, bancário, de telecomunicações, entre outros setores que utilizam baterias estacionárias. A Light e o CPqD realizaram o projeto de PeD Light-Aneel 033/2008. Este projeto teve como objetivo o aumento da confiabilidade dos serviços auxiliares das subestações e redução dos custos de manutenção. Para tal efeito, foi desenvolvido um sistema automatizado de monitoramento e gestão individual e remota de todos os elementos que compõe o banco de baterias. A pesquisa de mestrado avaliou, quantitativamente, a confiabilidade da medição remota realizada na subestação Baependi da Light, na cidade do Rio de Janeiro. A metodologia aplicada na presente dissertação consiste em estudos estatísticos (Testes de hipóteses paramétricos e não paramétricos) para comparação de resultados de tensão elétrica e impedância obtidos em condições reais de operação (Medições SIMBA-GEBAT) em relação ao equipamento portátil de medição. A pesquisa validou aos níveis de significância de 90 por cento, 95 por cento e 99 por cento, a metodologia empregada para avaliação remota de baterias para os ensaios de impedância e tensão elétrica e identificou a repetitividade da metodologia da avaliação remota. O resultado da pesquisa foi fundamental para provar a credibilidade do sistema de monitoramento remoto de baterias. A utilização desse sistema ora validado contribuirá para o aumento da confiabilidade dos equipamentos que utilizam sistema de backup, além de redução dos custos de manutenção preventiva. / [en] The present work has the general objective of validating, under real operation conditions, the technique (developed in a laboratorial environment) of remote monitoring of stationery batteries. The development of this MsC dissertation theme was motivated by the contributions that it is expected to give to the Light S.E.S.A. and other companies of the Electric Sector, Oil and Gas, Bank, IT and many others which use stationary batteries in their DC energy supply. Light and CPqD developed together a Research and Development Project named ReD Light-ANEEL 033/2008. This project had as its main objective to increase the reliability of the ancillary services of substations and to reduce their maintenance costs. To reach this target, was developed an automated monitoring system and a remote individual management of all elements that form the batteries bank. The MSc research evaluated, quantitatively, the reliability of the remote metering, performed to the Light’s Baependi substation, which is located in the south zone of Rio de Janeiro City. The methodology applied in this dissertation consists of statistical studies (Hypothesis testing parametric and nonparametric), for comparison of voltage and impedance results obtained in actual operating conditions (Measurements SIMBA-GEBAT) compared to portable measurement. The research has validated, to the significance levels of 90 per cent, 95 per cent and 99 per cent, the methodology used to the remote evaluation of batteries relatively to the impedance and voltage essays, and has also identified the repetitivity of the remote evaluation methodology. The research results were fundamental to prove the credibility of the remote monitoring system of batteries. The use of this system will contribute to increase the reliability of the equipments which use backup systems, besides promoting a cost reduction of the predictive maintenance.
20

[en] METROLOGICAL EVALUATION OF THE INFLUENCE OF THE COMPOSITION OF THE NATURAL GAS ON FLOW RATE MEASUREMENTS IN PRESSURE RELIEF FLARE SYSTEMS / [pt] AVALIAÇÃO METROLÓGICA DA INFLUÊNCIA DA COMPOSIÇÃO DO GÁS NATURAL NA MEDIÇÃO DE VAZÃO EM SISTEMAS DE ALÍVIO DE PRESSÃO TIPO TOCHA

FAGNER GEOVANI DE SÁ 25 March 2015 (has links)
[pt] Esta dissertação de mestrado teve por objetivo avaliar a influência da composição do gás natural na medição de vazão pela técnica de ultrassom em sistemas de alívio de pressão tipo tocha. A inclusão da composição do gás na correção da medição da vazão do gás em sistemas de tocha constitui uma exigência legal imposta pelo regulador brasileiro do setor de petróleo, gás natural e biocombustíveis. A histórica dificuldade técnica associada à coleta de amostras de gás em sistemas de tocha e os constantes questionamentos sobre a representatividade das amostras coletadas são as principais motivações para a realização deste estudo. A metodologia utilizada fundamentou-se em pesquisa bibliográfica, documental e de campo. Por meio de pesquisa bibliográfica, documental e normativa realizou-se o embasamento técnico e teórico do estudo. A pesquisa de campo teve por finalidade coletar informações de estações de medição de gás em sistemas de tocha de uma unidade marítima de produção de petróleo e gás. A partir do tratamento das informações coletadas, os resultados da pesquisa permitiram quantificar que o erro máximo na medição de vazão de gás por ultrassom devido ao desconhecimento de sua real composição é 0,04 porcento. Dentre as conclusões, (i) as amostras de gás coletadas em sistemas de tocha não representam de forma adequada o volume de gás medido e (ii) o erro máximo estimado associado à totalização do volume de gás mostrou-se desprezível quando comparado ao volume total de gás documentado nos históricos de medição e aos erros aleatórios aceitáveis para o tipo de estação de medição considerado. / [en] The objective of this dissertation is to evaluate the influence of the composition of the natural gas on the flow rate measurements in pressure relief flare systems. The consideration of the gas composition in the correction of the gas flow rate measurements in the flare system is a legal requirement imposed by the Brazilian regulating agency for oil, natural gas and biofuels. The historical technical difficulties associated with collecting gas samples from flare systems and the constant questions about the representativeness of the collected samples are the main motivations for this study. The methodology used was based on literature, documental and field research. Through literature, documental and normative research was conducted at the technical and theoretical foundation of the study. The field research aimed at collecting information of measurement systems of gas flare in a maritime unit of oil and gas production. From the treatment of collected information, the research results allowed to quantify that the maximum error in the measurement of gas flow rate by ultrasonic meters due to the lack of knowledge of its actual composition is 0.04 percent. Among the conclusions, (i) the collected gas samples in flare systems do not adequately represent the volume of measured gas and (ii) the estimated maximum error associated with the totalization of the gas volume was found to be negligible compared to the documented total volume gas on historical measurements and to acceptable random errors for the type of the considered measurement system.

Page generated in 0.1459 seconds