[en] METROLOGICAL RELIABILITY OF FLOW RATE MEASUREMENT IN HYDROELECTRICAL COOLING WATER SYSTEM / [pt] CONFIABILIDADE METROLÓGICA DA SUPERVISÃO DE VAZÃO EM SISTEMA DE RESFRIAMENTO A ÁGUA EM USINAS HIDRELÉTRICAS

CARLA CITO ACCIOLY 30 August 2007 (has links)
[pt] A supervisão da vazão da água de resfriamento em equipamentos de produção de energia de usinas hidrelétricas tem sido uma questão de preocupação devido à possibilidade de obstrução dos equipamentos de medição pela água sem tratamento. Outrossim, por razões econômicas, um instrumento barato e confiável deve ser escolhido para os vários pontos de monitoramento. Neste trabalho, um dispositivo não intrusivo foi desenvolvido, tendo seu desempenho avaliado para a medição da vazão da água na faixa de 0,7 a 7 m3/h. O princípio básico de operação é a variação da freqüência de formação de vórtices como função da vazão. Um acelerômetro colocado na parede externa de uma tubulação mede a freqüência de vibração induzida pelos vórtices. Vários testes mostraram que o instrumento é sensível a ruídos, que devem ser filtrados para a redução da incerteza de medição. O número de Strouhal foi avaliado como função do número de Reynolds do escoamento, mostrando um comportamento assintótico para números de Reynolds elevados. O instrumento diferencia nitidamente a existência ou não de escoamento. Presentemente, um esforço para condicionamento do sinal está sendo feito para a redução da incerteza de medição da vazão, que é estimada nesta dissertação. / [en] The supervision of the cooling water flow rate in power producing equipments of hydro-electric plants has been an issue of concern due to the possibility of clogging up measurement instruments by the used non treated flowing water. Furthermore, for economic reasons, a cheap and reliable instrument must be chosen for each of the many monitoring points. In this work, a non-intrusive device was developed and its performance analized for measuring water flow rate in the 0,7 to 7 m3/h range. The basic operating principle is the variation of the vortex shedding frequency with flow rate. An accelerometer placed outside the pipe wall measures the vortex induced vibration frequency. Several tests showed that the instrument is noise sensitive, which must be filtered to reduce the uncertainty of measurement. The Strouhal number was plotted as a function of the flow Reynolds number, showing an asymptotic trend towards an approximately constant value at high Reynolds numbers. The instrument sharply differenciates between flow and non-flow situations. Presently, a signal conditioning effort is being conducted to reduce the uncertainty of measurement of the flow rate, which is estimated in this dissertation.
22

[en] A METHODOLOGY FOR METROLOGICAL EVALUATION AND DETERMINATION THE FREQUENCY OF CALIBRATION IN FISCAL AND ALLOCATION NATURAL GAS MEASUREMENT SYSTEMS / [pt] METODOLOGIA PARA AVALIAÇÃO METROLÓGICA E DETERMINAÇÃO DA PERIODICIDADE DE CALIBRAÇÃO EM SISTEMAS DE MEDIÇÃO FISCAL E APROPRIAÇÃO DE GÁS

JOSE LUIZ DIAS 13 December 2007 (has links)
[pt] No presente trabalho, de interesse da indústria de petróleo, é desenvolvida uma metodologia para avaliação metrológica e determinação da periodicidade de calibração em sistemas de medição de vazão de gás natural com placas de orifício, usando históricos de dados bimestrais de medidores instalados em pontos fiscais da bacia de Campos. O estudo analisa dados de calibração de medidores de temperatura, pressão e pressão diferencial de um transmissor eletrônico de vazão multivariável, contribuindo para o entendimento do impacto das incertezas destas variáveis na incerteza total do sistema de medição como um todo. Como resultados das avaliações metrológicas, foram determinados intervalos entre calibrações sucessivas, de modo que as exigências de incerteza de medição da portaria conjunta no 1 ANP/INMETRO de 19/6/2000 possam ainda ser atendidas nos pontos de medição fiscal e de apropriação . Inicialmente, foi mostrado que os valores de incertezas calculadas de vazão pela norma ISO 5167-2 (2003) atendem os requisitos da portaria. Finalmente, foi mostrado que o intervalo entre calibrações sucessivas dos medidores poderia ser aumentado do valor atualmente requerido pela portaria (2 meses) para pelo menos 6 meses para pressão diferencial e pressão, e 14 meses para temperatura. Este resultado tem um impacto econômico e operacional nas empresas de gás natural. / [en] In the present work, of interest of the oil industry, a methodology was developed for metrological evaluating and determination the frequency of calibration of natural gas flow rate measurement systems with orifice plates, using calibration data obtained every two months from measurement instruments installed in fiscal points of the Campos Basin. The study evaluates the calibration data of temperature, pressure and differential pressure measurement from a multivariable transmitter, contributing to a better understanding of the influence of those variables in the uncertainty of flow rate as a result of the methodological evaluating, the intervals between two successive calibrations was determined, so that the requirements of the Portaria Conjunta n° 1 ANP/INMETRO, 19/06/2000, could be met in the fiscal and allocation points. First of all, it was shown that the flow rate uncertainty values, as calculated by ISO 5167-2 standard was fully covered by the requirements. Finally, it was shown the interval between successive calibrations could be increased of the value nowadays required by portaria (2 months) to 6 months for pressure and differential pressure, and to 14 months for temperature. This results has an economic and operational impact in the natural gas industry.
23

[en] PRIMARY AND HARMONIZATION OF THE REFERENCE VALUES: INTERNATIONAL EXPERIENCE AS CONTRIBUTION TO A BRAZILIAN SYSTEM FOR MEASURING THE FLOW OF NATURAL GAS / [pt] PADRONIZAÇÃO PRIMÁRIA E HARMONIZAÇÃO DE VALORES DE REFERÊNCIA: CONTRIBUIÇÃO DA EXPERIÊNCIA INTERNACIONAL À FORMULAÇÃO DE UM SISTEMA BRASILEIRO PARA MEDIÇÃO DE VAZÃO DE GÁS NATURAL

JULIO CESAR DA COSTA COMINGES 30 October 2008 (has links)
[pt] Objetivo da presente dissertação de mestrado é contribuir para a estruturação da cadeia metrológica de vazão de gás natural em alta pressão no Brasil, tomando como base experiências bem sucedidas de laboratórios nacionais de metrologia de vazão de países industrializados. O estudo fundamenta-se na padronização primária e na harmonização de valores padrões de referência para a medição de vazão. A falta de infra-estrutura metrológica para padronização primária de medição de vazão volumétrica de gás natural no Brasil constituiu-se na motivação da Petrobras para eliminar essa importante vulnerabilidade e, dessa forma, contribuir para o estabelecimento do controle metrológico no setor. A escolha do projeto de pesquisa também foi motivada pelo interesse pessoal do autor em contribuir para o tema tendo em vista sua trajetória profissional na Petrobras. A exemplo da experiência de outros países produtores de petróleo e gás natural, o trabalho se desenvolveu no contexto da regulação do setor, que criou oportunidades de investimentos e impôs desafios à metrologia brasileira. Demandas por medição fiscal de apoio a contratos de transferência de custódia exigiram a introdução de uma legislação específica e o desenvolvimento de procedimentos de avaliação da conformidade do gás natural, promissor insumo na matriz energética brasileira. O trabalho desenvolveu-se de acordo com a seguinte metodologia: (i) revisão das melhores práticas laboratoriais e dos modelos de padronização em uso por conceituados Institutos Nacionais de Metrologia de países produtores de petróleo e gás e (ii) na interpretação dos procedimentos de harmonização dos valores de referência utilizados pelos institutos nacionais de metrologia estudados. Dentre os resultados do estudo destaca-se a caracterização das cadeias de rastreabilidade para medição de vazão de gás natural em alta pressão em uso por institutos nacionais de metrologia que acordaram harmonizar seus valores de referência (PTB/Alemanha, LNE/França, NMi/Holanda). Disponibiliza-se, assim, um acervo de informações relevantes que poderá subsidiar a estruturação de um sistema de padronização primária no País. Como conclusão, o trabalho propõe a implementação de um modelo de poadronização primária para medição de vazão volumétrica de gás natural no Brasil. / [en] The objective of this Master dissertation in metrology is to contribute for structuring the Brazilian traceability chain for flow measurement of natural gas at high pressure, based on successful experiences of national metrology laboratories of highly industrialized countries. The study takes into account the primary standardization and harmonization of reference measurement standards. The lack of an adequate infrastructure for primary standardization of volumetric flow measurement of natural gas in Brazil was a motivation motivation for Petrobras to invest substantially to overcome this important vulnerability, thus contributing to the establishment of the metrological control in the gas sector. The choice of the research project was also motivated by the author`s personal interest to contribute to the advance knowledge in an area that he has been working for many years at Petrobras. Following the experience of other oil and gas producing countries, this project was developed in the context of the regulation for the sector creating opportunities for investment on quality infrastructure, imposing challenges for the Brazilian metrology. The need to implement a measuring fiscal scheme to support contracts for custody transfer required a specific legislation and the development of procedures for conformity assessment of natural gas. The work was developed in accordance with the following methodology: (i) review of best practices and models of laboratory standardization in use by authoritative national institutes of metrology of oil and gas producing countries and (ii) interpretation of procedures for harmonization of reference values used by the National Metrology Institutes studied. The main results obtained is the characterization of the traceability chain associated with natural gas for measurement at high pressure in use by European national metrology institutes (PTB/Germany, LNE/France, NMi/Netherlands) which have agreed to harmonize their reference values. Strategic information is then made available that could subsidize the structuring of a system of primary standardization of flow measurement in Brazil. In conclusion, this work has suggested a metrological scheme for implementing a sound gas flow measurement metrology primary standardization.
24

[en] METROLOGICAL RELIABILITY OF LUNG VENTILATORS / [pt] CONFIABILIDADE METROLÓGICA DE VENTILADORES PULMONARES

JORGE CALDERON ROMERO 01 November 2006 (has links)
[pt] O presente trabalho apresenta a avaliação da garantia da confiabilidade metrológica de um equipamento eletromédico (EEM), o ventilador pulmonar, também conhecido como ventilador mecânico. A falta de confiabilidade metrológica nesses equipamentos pode resultar na ocorrência de efeitos danosos, conforme a sua qualificação quanto ao potencial de risco à saúde dos usuários (operadores e pacientes). Apesar de ser fundamental para garantir o efeito desejado, a avaliação da confiabilidade geralmente não é realizada durante o período de uso (póscomercialização). Considerando a falta de informação em metrologia no ambiente da saúde e os poucos estudos de metrologia aplicados a esta área indicando os riscos da falta de avaliação metrológica, é de especial relevância a realização de investigações neste campo de pesquisa. Na presente dissertação foram realizadas medições para avaliação da confiabilidade metrológica de ventiladores pulmonares utilizando informações técnicas e normativas. Realizou-se um estudo bibliográfico minucioso dos princípios básicos de funcionamento dos ventiladores pulmonares e suas especificações técnicas. Para a realização das medições foram estudadas referências tais como normas nacionais e internacionais, manuais dos fabricantes do equipamento e publicações sobre manutenção de EEM. Medições para a avaliação metrológica de dez (10) ventiladores pulmonares, 6 da marca I modelo I.1 e 4 da marca II modelo II.2, foram realizadas em um hospital público. A exceção de um ventilador novo, todos os ventiladores pulmonares avaliados apresentaram não conformidades. Os resultados obtidos na avaliação da confiabilidade metrológica dos ventiladores pulmonares assinalam a urgente necessidade de avaliação metrológica periódica destes EEM. Verificou-se também a necessidade de avaliação de parâmetros cuja obrigatoriedade de medição não consta na norma aplicável. De uma forma ampla, o presente trabalho contribui para a conscientização de profissionais da saúde e da área de metrologia quanto à importância da avaliação da confiabilidade metrológica periódica de ventiladores pulmonares. / [en] The present Masters dissertation evaluates the metrological reliability of pulmonary ventilators, also known as mechanical ventilators. Pulmonary ventilators are electromedical equipment (EEM). The absence of metrological reliability of a pulmonary ventilator may result in dangerous consequences, according to its classification by the potential risk to the health of users (operators and patients). Even though it is of fundamental importance to guarantee the desired effect, the evaluation of reliability, in general, is not performed during the post-sale period. Considering the lack of information in metrology in the field of health, and that there are few studies indicating the risks of the absence of metrological evaluations, research in this field are especially relevant. In the present dissertation, measurements based on technical and regulatory information were performed in order to evaluate the metrological reliability of pulmonary ventilators. A meticulous bibliographical study of the basic principles and technical specifications of pulmonary ventilators was performed. The measurements were based on national and international standards, manufacturer manuals, and EEM maintenance publications. Measurements for the metrological evaluation of ten (10) pulmonary ventilators, 6 of brand I model I.1 and 4 of brand II model II.2, were performed in a public hospital. Except for a new unit, all evaluated pulmonary ventilators presented non- conformities. These results indicate an urgent need for periodic metrological evaluations of these EEMs. In addition, the need for evaluations of parameters not included in the current standards was verified. The present work contributes for increasing the awareness of health and metrology professionals regarding the importance of periodical evaluations of the metrological reliability of pulmonary ventilators.
25

[en] GAS FLOW MEASUREMENT IN FLARE SYSTEMS / [pt] MEDIÇÃO DE VAZÃO DE GÁS EM SISTEMAS DE FLARE (TOCHA)

TABITA YALING CHENG LOUREIRO 26 February 2019 (has links)
[pt] Anualmente, mais de 100 bilhões de metros cúbicos de gás são queimados mundialmente em flares nas instalações de petróleo e gás natural. Esse número era ainda maior a alguns anos atrás. No passado, o holofote estava sobre o petróleo e o gás natural era visto como uma fonte de energia não rentável. A preocupação mundial com o aquecimento global impulsionou as ações para redução das emissões de gases causadores do efeito estufa. A crescente mobilização dos órgãos reguladores de diversos países para imposição de restrições de queima e ventilação do gás natural vem contribuindo para a melhoria dos índices de aproveitamento do gás associado. Muito embora já tenha havido um avanço relevante, o montante de gás desperdiçado ainda precisa ser reduzido. Neste contexto, a necessidade de se quantificar corretamente os volumes desperdiçados de gás fica evidente. As ações para redução da queima ou ventilação de gás natural se baseiam fortemente em medições precisas. O reflexo disto são as constantes publicações de diretrizes regulatórias voltadas para as medições de vazão de gás dos sistemas de alívio/tocha. Apesar da medição de gás de flare não ser uma técnica nova, ela ainda é considerada desafiadora e bem diferente das demais aplicações de medição de vazão. A natureza imprevisível da queima de gás natural, associada a instalações inadequadas, torna a medição extremamente difícil e complexa. O presente trabalho traz uma visão geral da queima de gás natural, da regulação do tema no Brasil e no mundo e das características e desafios da medição de gás de flare. Adicionalmente, foram feitos estudos de incerteza sobre os volumes diários medidos nos pontos fiscais de gás de uma instalação típica, de forma a analisar a influência da incerteza da medição do gás de tocha sobre a incerteza da produção mensal de gás natural, que é a base de cálculo para as devidas participações governamentais. Também foram calculadas as diferenças obtidas entre a medição indireta (balanço volumétrico de gás) e a medição direta (medição ultrassônica) da queima de gás natural e as incertezas relacionadas à medição indireta. / [en] Annually, more than 100 billion cubic meters of gas are flared from upstream oil and gas facilities. This number was even higher a few years ago. In the past, the spotlight was on oil and natural gas was seen as a non-profitable source of energy. The worldwide concern over global warming spurred actions to reduce emissions of greenhouses effect gases, contributing to change the scenario above. The increased mobilization of regulators from many countries enforcing gas flaring and venting restrictions has contributed to the improvement of gas use. However, although some progress has been already achieved, the amount of wasted gas still needs to be reduced. In this context, the need to correctly quantify the volumes of gas flared is evident. Actions to reduce the flaring or venting of natural gas rely heavily on accurate measurements. This reflects on the rigorous flare measurement guidelines introduced by many countries to support flaring legislation. Although the flare gas measurement is not a new technique, it is still considered a challenging task and quite unique compared to other flow measurement applications. The unpredictable nature of the flaring, many times happening at inadequate facility, makes measuring it extremely difficult and complex. This work provides an overview of gas flaring, regulatory requirements in Brazil and worldwide and the characteristics and challenges of flare gas measurement. In addition, uncertainty studies were made over the daily volumes measured in the fiscal points of a typical installation, in order to analyze the influence of the uncertainty of flared gas measurement on the uncertainty of monthly gas production, which is the basis for calculating the government takes. The differences obtained between the gas flaring indirect measurement (bydifference method) and direct measurement (ultrasonic measurement) were also calculated, as well as the uncertainties related to the indirect measurement.
26

[en] PROPOSITION AND VALIDATION OF A GRAVIMETRIC SYSTEM FOR CALIBRATION OF FLOW RATE METERS FOR LIQUIDS / [pt] PROPOSIÇÃO E VALIDAÇÃO DE SISTEMA GRAVIMÉTRICO PARA CALIBRAÇÃO DE MEDIDORES DE VAZÃO DE LÍQUIDOS

JOSE DANIEL HERNANDEZ VASQUEZ 12 March 2019 (has links)
[pt] A dissertação tem por objetivo propor e validar um sistema gravimétrico para a calibração de medidores de vazão de líquidos. A motivação pela escolha do tema resultou da necessidade identificada junto ao setor de petróleo e gás para assegurar que as medições de vazão demandadas pelo setor sejam rastreáveis a padrões nacionais e satisfaçam as exigências contratuais e regulatórias aplicáveis. A metodologia utilizada permitiu avaliar a confiabilidade metrológica dos instrumentos não-automáticos de pesagem (em conexão ao sistema gravimétrico) e intercomparar, metrologicamente, diferentes alternativas de medição do volume dos reservatórios integrados ao sistema gravimétrico. Os resultados da pesquisa permitiram (i) estimar a confiabilidade metrológica dos instrumentos não-automáticos de pesagem em 0,04 kg para a balança Alfa modelo 3107 e 0,14 g para a balança OHAUS modelo Explorer Pro; e (ii) definir uma faixa de incerteza de 0,02 por cento a 0,05 por cento associada à calibração do sistema gravimétrico, dependendo do volume de fluido de trabalho transferido no processo de calibração. Como conclusão, o sistema gravimétrico para calibração de medidores de vazão de líquidos foi considerado validado à luz das incertezas reportadas, assim contribuindo para o avanço do conhecimento na área da metrologia de vazão. / [en] The objective of this MSc. dissertation is to propose and to validate a gravimetric system for the calibration of flow meters for liquids. The motivation for the choice of this theme resulted from the need identified by the oil and gas sector to ensure that measurements of flow rate demanded by the sector can be traceable to national standards and attend the contractual and regulatory requirements. The methodology used allowed to evaluate the metrological reliability of non-automatic weighing instruments (in connection with the gravimetric system) and compare, metrologically, different options for measurement of volume of reservoirs in connection with the gravimetric system. The research results allowed (i) to estimate the metrological reliability of non-automatic weighing instruments in 0,04 kg for the balance Alfa model 3107 and 0,14 g for the balance OHAUS model Explorer Pro; and (ii) to define an uncertainty range of 0.02 percent to 0.05 percent associated with the gravimetric system, depending of volume of the working fluid transferred in the calibration process. In conclusion, the gravimetric system for calibration of flow meters liquid was considered valid with the reported uncertainties, thus contributing to the advancement of knowledge in the area of flow metrology.
27

[en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS / [pt] MEDIÇÃO DE ILUMINÂNCIA POR DISPOSITIVOS MÓVEIS: UMA ANÁLISE COMPARATIVA DE DIFERENTES PLATAFORMAS E APLICATIVOS

VIVIANE GODINHO VAZ 31 January 2019 (has links)
[pt] A iluminância do ambiente apresenta impacto fisiológico, emocional e de produtividade, em função das atividades que os indivíduos estejam desempenhando. Normas técnicas internacionais, que são adotadas no Brasil pela ABNT, apresentam requisitos necessários para os níveis de iluminância existentes em ambientes indoor de forma a garantir segurança, conforto e eficiência em tarefas visuais durante todo um período de trabalho. Instrumentos de medição, como luxímetros, em geral, não são utilizados no quotidiano. No entanto, a possibilidade de que os sensores já existentes em dispositivos móveis possam realizar essas medições de iluminância tornará viável sua aplicação no quotidiano do usuário, permitindo avaliar a adequação dessa grandeza durante suas atividades diárias. Resultados preliminares disponíveis na literatura, comparando o desempenho de dispositivos móveis associados a diferentes aplicativos comparados aos resultados de medição fornecidos por um luxímetro, apontam para a inadequação da resposta dos dispositivos móveis. Por outro lado, há possibilidade de que o uso de uma cúpula difusora acoplada ao dispositivo móvel possa impactar em seu desempenho de forma a viabilizar a aplicação na medição de iluminância. Assim, neste trabalho são realizados estudos para análise da confiabilidade dos resultados de medição da iluminância obtidos pelos sensores já existentes em smartphones e tablets, utilizando ou não uma cúpula difusora. As medições foram feitas utilizando um luxímetro digital, e um conjunto de dispositivos de telefonia móvel ou tablet associados a diferentes aplicativos, com e sem cúpula difusora anexada. Dois arranjos experimentais foram desenvolvidos: um para medições utilizando uma lâmpada LED, e outra montagem utilizando uma lâmpada de xenônio. Com a análise comparativa evidenciou-se o impacto da utilização da cúpula difusora, a qual possibilitou que algumas das combinações dispositivo/aplicativo alcançassem desempenho adequado para sua aplicação na avaliação quotidiana de iluminância. / [en] The illuminance of the environment has a physiological, emotional and productivity impact, depending on the activities that individuals are performing. International technical standards, such as ISO 8995-1: 2002 (CIE S 008 / E: 2001), also adopted in Brazil by ABNT, present requirements for the levels of illuminance existing in indoor environments in order to guarantee safety, comfort and efficiency in visual tasks throughout a work period. Measuring instruments such as luxmeters, are not used in everyday life. However, the possibility that the existing sensors in mobile devices can perform these measurements of illuminance will make its application viable in the daily life of the user, allowing to evaluate the adequacy of this greatness during his daily activities. Preliminary results available in the literature, comparing the performance of mobile devices associated with different applications in relation to the measurement results provided by a luxmeter, point to the inadequacy of the response of the mobile devices. On the other hand, it is possible that the use of a diffuser dome coupled to the mobile device may impact its performance to enable the application in the illuminance measurement. Thus, in this work are carried out studies to analyze the reliability of the illuminance values obtained by sensors already existing in smartphones and tablets, using or not a dome diffuser. The measurements were made using as reference, a digital luxmeter, and a set of mobile or tablet devices associated with different applications, in situations with and without diffuser dome attached. Two experimental arrangements were developed: one for measurements using a LED lamp, and another assembly using a xenon lamp. With the comparative analysis, the impact of the use of the diffusion dome was evidenced. The attachment of the dome enabled some of the device/application combinations to achieve adequate performance for application in the daily assessment of illuminance.
28

[en] EFFECTIVENESS OF A TECHNOLOGICAL SOLUTION FOR REDUCING ELECTRICAL ENERGY PILFERAGE IN DISTRIBUTION COMPANIES: A CASE STUDY / [pt] EFICÁCIA DE SOLUÇÃO TECNOLÓGICA PARA REDUÇÃO DE FURTOS DE ENERGIA ELÉTRICA EM EMPRESAS DISTRIBUIDORAS: ESTUDO DE CASO

CLAUDIA ZUCCOLOTTO REIS 03 March 2006 (has links)
[pt] As perdas de energia elétrica, particularmente as comerciais, constituem problema importante e complexo para as empresas distribuidoras. O problema só se apresenta de forma aguda nos países em desenvolvimento, onde o percentual de perdas por furto é elevado e adquire importantes conotações sociais, políticas e culturais. Isso explica o fato de empresas brasileiras de distribuição de energia elétrica investirem recursos apreciáveis para mitigar esse problema e ressalta a importância de um tema ainda pouco explorado na literatura técnico-científica. Esta dissertação, de caráter exploratório, tem como objetivo estudar o problema de perda de energia por desvio e a eficácia de soluções tecnológicas investigando o caso de uma empresa e os resultados obtidos em projeto recente. Ao tempo do estudo, a empresa implantava uma tecnologia cujo objetivo principal era identificar os clientes que desviam energia elétrica e, posteriormente, tornar o processo de faturamento automatizado. O estudo partiu de algumas questões julgadas mais relevantes, incluindo: Quanto a empresa ganhou com a instalação desta tecnologia? Como se comporta o consumo dos clientes antes e depois da instalação da tecnologia? Há correlação entre o ganho da empresa e o poder aquisitivo da população da área? Há efeito demonstração de uma área sobre suas vizinhas? A partir destas questões foram analisadas séries de dados referentes ao consumo medido antes e após a instalação da nova tecnologia. Os resultados indicam a viabilidade da tecnologia como eficaz paliativo de curto-prazo para o problema cuja solução definitiva envolve tratamento concomitante dos aspectos sociais, políticos e culturais. / [en] Electrical energy losses, chiefly, commercial losses, constitute an important and complex problem for energy distribution companies worldwide. However, only in developing countries the problem becomes acute because theft losses are large, and coupled with social, legal, political and cultural issues. This explains why Brazilian energy distribution companies dedicate sizable investments for mitigating the problem, and stresses the importance of a theme still largely unexplored in the technical-scientific literature. This thesis, of exploratory nature, addresses the problem and assesses the effectiveness of technological solutions by investigating the case of a recent project developed in a Brazilian company. At the time of the research, the company was implementing a new and original technology, whose main objective was to identify pilfering clients, and later on, to make the billing process more automated. The study started with some questions judged more relevant, including: How large was the gain yielded by the new technology? How does the energy consumption behave after the technological change? Is there a correlation between the gain obtained and the areas of lesser purchasing power? Is there a demonstration effect upon neighboring areas? Starting from these questions, series of historical data on measured consumption before and after the new technology were analyzed. The results indicate the feasibility of the technology as an effective shortterm palliative for the problem whose ultimate solution involves the concurrent treatment of the social, legal, political e cultural aspects.
29

[en] METROLOGICAL EVALUATION OF PROCEDURES FOR QUALIFICATION AND ACCEPTANCE OF BATTERIES FOR PHOTOVOLTAIC SYSTEMS / [pt] AVALIAÇÃO METROLÓGICA DE PROCEDIMENTOS DE QUALIFICAÇÃO E ACEITAÇÃO DE BATERIAS PARA SISTEMAS FOTOVOLTAICOS

MARGARETH NUNES SILVA 06 November 2006 (has links)
[pt] Este trabalho visa a analisar criticamente os procedimentos disponíveis para ensaios de baterias e sugerir modificações que os aperfeiçoem no âmbito do Programa Brasileiro de Etiquetagem (PBE), de modo a fornecer elementos que permitam avaliar o desempenho de Sistemas Fotovoltaicos para geração de energia elétrica em uma gama variada de situações. Para cada um dos procedimentos avaliados utilizou-se uma bateria com características elétricas semelhantes, porém, de fabricantes diferentes. Os resultados foram posteriormente processados utilizando-se o programa MATLAB. Com base na incerteza de medição estimada da capacidade da bateria, foram estabelecidos critérios para qualificação e aceitação do seu desempenho.Como ponto crítico dos ensaios, foi observado que a temperatura de teste e o nível de tensão de carga devem ser cuidadosamente estabelecidos para que os resultados sejam representativos do desempenho da bateria. Foi concluído que a temperatura e a corrente de descarga são as variáveis de maior influência na medição da capacidade da bateria, e que a eficácia dos critérios para qualificação e aceitação do desempenho da bateria fica comprometida sem a utilização de sua incerteza de medição. / [en] The purpose of this work is to critically analyze the available procedures to test batteries and to suggest modifications that improve them in the context of the Brazilian Labeling Program (PBE), in order to provide elements to evaluate the performance of Photovoltaic Systems for electric energy generation under different operating conditions. Different types of batteries were used for each of the two testing procedures, from different manufactures. The results were processed using a MATLAB software. The uncertainty of measurement of the measured battery load was used to establish a criterium for qualifications and acceptance of its performance. As a critical point, it is observed that test temperature was a key factor and must be carefully taken into account so that the results be representative of the battery performance. Finally it was concluded that temperature and the discharge current have a larger contribution to measuring its load, and that the qualification and acceptance criterium is not complete if the uncertainty of measurement is not taken into account.
30

[en] EVALUATION OF VOLUMES CORRECTION METHODS OF LIQUID PETROLEUM DERIVATIVES / [pt] AVALIAÇÃO DE MÉTODOS DE CORREÇÃO DE VOLUMES DE DERIVADOS LÍQUIDOS DE PETRÓLEO

CARLOS VINICIUS CALDAS CAMPOS 20 September 2018 (has links)
[pt] O objetivo desta dissertação é quantificar e analisar as possíveis diferenças oriundas de métodos de correção de volume de diferentes normas na medição de derivados líquidos de petróleo. Essas correções são necessárias pois variações na temperatura e pressão a que esses fluidos estão submetidos geram variações de volume que podem levar a grandes diferenças entre os volumes medidos por clientes e fornecedores, em virtude de variações nas condições operacionais. De forma a minimizar a influência dessas variações nos volumes a serem considerados, estabeleceu-se uma condição padrão (20 graus Celsius e 101,325 kPa) para a qual todos os volumes medidos nas transações realizadas no Brasil devem ser corrigidos. A motivação deste trabalho advém do fato da regulamentação brasileira que rege essas correções ser muito antiga (anos 1970). Esse trabalho é uma oportunidade para analisar métodos de correção de volume mais recentes. Esses métodos podem gerar erros menores nas suas correções a depender das hipóteses adotadas em seus desenvolvimentos. Além disso, uma análise do impacto econômico da adoção desses métodos é realizada. Para estudar estas possíveis diferenças, a metodologia aplicada utiliza distribuições que modelam a variação da massa específica dos produtos ao longo do processo produtivo e, para outros, dados coletados ao longo de certos períodos especificados. São, então, obtidas massas específicas resultantes da aplicação de cada método. De posse das massas específicas calculadas nos resultados, são verificadas diferenças estatisticamente relevantes entre as correções efetuadas por cada método. As conclusões demonstram que essas diferenças justificam a atualização da regulamentação com os métodos contidos nos padrões mais atuais. / [en] The aim of this dissertation is to quantify and analyze the possible differences caused by the application of the correction methods defined on different standards for the measurement of the volume of liquid petroleum derivatives. This correction is necessary because pressure and temperature variations can cause considerable differences between measurements made by customer and supplier, due to operational conditions variations. To standardize this measurement, it was established that all volumes used on transactions in Brazil should be corrected to a base condition (in Brazil, 20 degrees Celsius and 101.325 kPa). This work s motivation comes from the fact that the Brazilian regulation is quite old (from the 1970s). This work is an opportunity to analyze more recent correction methods. These methods can give smaller errors depending on the hypothesis adopted in its developments. Besides that, an economic impact analysis of these methods adoption in realized. To study these possible differences, the applied methodology uses statistical distributions that model the specific gravity of the products during the productive process and, in other cases, uses data collected during certain periods. Corrected specific gravity values are, then, obtained for each method. With these values at hand, some statistically relevant differences are verified. Conclusions demonstrate that these differences justify the update of Brazilian regulation with the methods contained in standards that are more recent.