Spelling suggestions: "subject:"amostras"" "subject:"mostras""
21 |
Preparo de amostras e análise elementar de produtos farmacêuticos / Sample preparation and elemental analysis of pharmaceutical samplesGarcia, Mariana Ortega 17 August 2016 (has links)
Submitted by Alison Vanceto (alison-vanceto@hotmail.com) on 2017-05-02T11:45:04Z
No. of bitstreams: 1
DissMOG.pdf: 2518686 bytes, checksum: b36cdc87be463b9695f94ad353e145d0 (MD5) / Approved for entry into archive by Ronildo Prado (ronisp@ufscar.br) on 2017-05-04T12:43:58Z (GMT) No. of bitstreams: 1
DissMOG.pdf: 2518686 bytes, checksum: b36cdc87be463b9695f94ad353e145d0 (MD5) / Approved for entry into archive by Ronildo Prado (ronisp@ufscar.br) on 2017-05-04T12:44:05Z (GMT) No. of bitstreams: 1
DissMOG.pdf: 2518686 bytes, checksum: b36cdc87be463b9695f94ad353e145d0 (MD5) / Made available in DSpace on 2017-05-04T12:47:24Z (GMT). No. of bitstreams: 1
DissMOG.pdf: 2518686 bytes, checksum: b36cdc87be463b9695f94ad353e145d0 (MD5)
Previous issue date: 2016-08-17 / Não recebi financiamento / The medicine manufacture process may cause the final product contamination with
metallic residues to the detriment of human healthy. Aiming to regulate the
pharmaceutical production and establish standards of final products quality,
organizations such as the USP, EMA and ICH established regulations governing
maximum exposure to target elements, including some metals that are known to be
toxic to human health. Other elements, despite its essentiality in certain
concentrations, require exposure control. Regularly a sample to be measured by ICP
techniques requires its conversion to a representative solution, usually involving
microwave-assisted acid digestion. Once decomposed, the elemental analysis is done
using inductively coupled plasma techniques. This study aims to establish a general
method of sample preparation and elemental analysis of drug samples (excipients,
continuous use drugs, multivitamins, multiminerals and natural products), in order to
meet the demands of the pharmaceutical industry. In this sense, sample preparation
was based on microwave assisted acid digestion using the following reagents: nitric
acid, hydrochloric acid and hydrogen peroxide. The established procedure involves a
41 min heating program with a maximum temperature of 210 oC. The efficiency of
digestion was assessed by determination of dissolved organic carbon. Best digestions
were reached using 5 ml of inverted aqua regia for 500 mg of sample. The elemental
analysis techniques used were ICP OES and ICP-MS. In both cases, analytical
calibration curves were built based on the J value, established by USP, which takes
into account the permitted daily exposure to the target element, the maximum daily
dose of medicament and the sample dilution factor. Both techniques were suitable for
metal impurities determination. For ICP OES recoveries were close to 100% for most
analytes in all tested samples. For ICP-MS, despite being within the range from 70 to
150% set by USP, recoveries still require further evaluation. / O processo de manufatura de produtos farmacêuticos pode causar ao
produto final contaminação por resíduos metálicos acarretando potenciais prejuízos à
saúde humana. Com o objetivo de regulamentar a produção farmacêutica e
estabelecer padrões de qualidade para o produto final, organizações como USP, EMA
e ICH estipularam regulamentações para estabelecer a exposição máxima aos
elementos-alvo, incluindo elementos notórios pela toxicidade ao ser humano. Outros
elementos, apesar da essencialidade em certas concentrações requerem controle de
exposição. Em geral, para que uma amostra seja analisada por técnicas de ICP
requer-se que a mesma seja convertida em uma solução representativa, geralmente
envolvendo digestão ácida assistida por radiação micro-ondas. Este estudo buscou
estabelecer um método geral de preparo de amostra e análise elementar de amostras
de produtos farmacêuticos (entre excipientes e fármacos de uso contínuo,
multivitamínicos, multiminerais e produtos naturais) visando atender a demanda da
indústria farmacêutica. Iniciou-se o estudo de preparo de amostra avaliando-se as
possíveis misturas ácidas para a digestão assistida por radiação micro-ondas,
envolvendo ácido nítrico, ácido clorídrico e peróxido de hidrogênio. Para isso foi
utilizado um programa de aquecimento de 41 min com temperatura máxima de 210
oC. A eficiência da digestão foi avaliada determinando-se o carbono orgânico
dissolvido. O procedimento estabelecido envolveu o uso de 5 mL de água régia
invertida para cada 500 mg de amostra ( tanto excipiente quanto produto final)a ser
digerida. Para a análise elementar foram utilizadas as técnicas de ICP OES e ICPMS.
Em ambos os casos as curvas analíticas de calibração foram construídas com
base no J estabelecido pela USP, que considera a exposição diária permitida para o
elemento alvo, a máxima dose diária do medicamento e o fator de diluição da amostra.
Ambas as técnicas de mostraram adequadas para a determinação de impurezas
metálicas. As recuperações apresentaram resultados próximos a 100% para a maioria
das amostras para medidas usando ICP OES. Para a técnica de ICP-MS, apesar de
apresentar valores dentro da variação de 70 a 150% estabelecida pela USP, os
resultados de recuperação ainda requerem uma avaliação mais detalhada.
|
22 |
Identificação e quantificação de bismuto total em amostras de solo em regiões de falhas geológicas por análise eletroquímica / Electrochemical determination of lead and bismuth radioisotopes in geological fault zones and its correlationBorsato, Natíza Graziele Martins [UNESP] 11 August 2017 (has links)
Submitted by Natíza Graziele Martins Borsato null (natiza_gmb@hotmail.com) on 2017-09-22T13:29:54Z
No. of bitstreams: 1
DEFESA Natiza G M Borsato.pdf: 2718459 bytes, checksum: 27005db75663dcc081fd9ab405793b95 (MD5) / Rejected by Monique Sasaki (sayumi_sasaki@hotmail.com), reason: Solicitamos que realize uma nova submissão seguindo a orientação abaixo:
O arquivo submetido está sem a ficha catalográfica.
A versão submetida por você é considerada a versão final da dissertação/tese, portanto não poderá ocorrer qualquer alteração em seu conteúdo após a aprovação.
Corrija esta informação e realize uma nova submissão contendo o arquivo correto.
Agradecemos a compreensão. on 2017-09-27T18:30:18Z (GMT) / Submitted by Natíza Graziele Martins Borsato null (natiza_gmb@hotmail.com) on 2017-10-04T02:10:48Z
No. of bitstreams: 1
DEFESA Natiza G M Borsato.pdf: 2725342 bytes, checksum: 2ca43e2f0da0345b3a705c0777b90ef3 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-04T17:27:11Z (GMT) No. of bitstreams: 1
borsato_ngm_me_sjrp.pdf: 2725342 bytes, checksum: 2ca43e2f0da0345b3a705c0777b90ef3 (MD5) / Made available in DSpace on 2017-10-04T17:27:11Z (GMT). No. of bitstreams: 1
borsato_ngm_me_sjrp.pdf: 2725342 bytes, checksum: 2ca43e2f0da0345b3a705c0777b90ef3 (MD5)
Previous issue date: 2017-08-11 / No presente trabalho estudou-se, a concentração de bismuto total em áreas com falhas tectônicas e sua correlação com os níveis de radioisótopos de chumbo e de emissão de radônio-222. As determinações de bismuto total em diferentes solos foram realizadas por análise eletroquímica pela técnica de voltametria de redissolução anódica. Os valores de bismuto total aumentaram de acordo com o aumento da profundidade na extração do solo em estudo. Evidenciando a existência de bismuto decorrente da emanação de radônio-222 e sugerindo a existência de falhas geológicas nas áreas estudadas. Por análise estatística (ANOVA) verificou-se uma correlação da concentração de chumbo total e o nível de emissão de radônio-222 com a concentração de bismuto total. Essa correlação indica que a fonte de bismuto é proveniente da cadeia de decaimento radioativo do urânio-238 e tório-232. / In this work, the total concentration of bismuth areas with tectonic faults and their correlation and their correlation with the levels of lead radioisotopes and radon-222 emission. The determination of total bismuth in different soils were performed by electrochemical analysis using anodic redissolution voltammetry technique. The total bismuth values increased according to the depth increase in the extraction of the soil under study, evidencing the existence of bismuth due to the emanation of radon-222 and suggesting the existence of geological faults in the studied areas. Statistical analysis (ANOVA) showed a correlation between the total lead concentration and the emission level of radon-222 with the total bismuth concentration. This correlation indicates that the bismuth source is from the radioactive decay chain of uranium-238 and thorium-232.
|
23 |
Plasma ultrafrio em armadilha atômica / Ultracold plasma in a magneto optical trapDulce Cristina Jacinto Rezende 23 March 2005 (has links)
Neste trabalho nós produzimos um plasma neutro ultrafrio de 85Rb através da fotoionização dos átomos aprisionados em uma armadilha magneto-óptica. Medimos o número de partículas que evaporam do plasma no momento de sua criação usando a técnica de tempo-de-vôo. A partir disto realizamos o estudo da taxa de evaporação com relação a energia cinética inicial do elétron fornecida ao sistema, onde para isto criamos o plasma com diferentes comprimentos de onda do laser de fotoinização. Nossos resultados indicam que conforme fornecemos mais energia ao sistema mais partículas evaporam e constatamos que está de acordo com a literatura. Interpretamos o resultado com um modelo analítico que considera a distribuição de energia de Maxwell-Boltzmann e encontramos a temperatura do plasma com relação a temperatura inicial dos elétrons / In this work we produced an ultracold neutral plasma of 85Rb formed by the photoionization of laser-cooled atoms. We measured the number of particles evaporated from the plasma in the moment of its formation using the time-of-flight technique. After this, we studied the evaporation rate as a function of the initial electron kinetic energy, for this we created the plasma at different wavelengths of the photoinization laser. Our results indicate that as we supplied more energy to the system more particles evaporate and we verified that it is in agreement with the literature. We interpreted the result with an analytic model that considers the Maxwell-Boltzmann energy distribution and we found the plasma temperature as a function initial electron temperature
|
24 |
Extração de mercúrio de solos e sedimentos auxiliada por ultra-somCollasiol, André January 2004 (has links)
Desenvolveu-se uma metodologia que dispensa a dissolução completa da amostra para determinar Hg em solos, sedimentos fluvial e marinho. O Hg é quantitativamente extraído do sedimento marinho usando-se HNO3 30% (v/v), ultra-som (120 s, 70 W) e granulometria ≤ 120 µm. Condições similares são eficientes para sedimento fluvial e solo, exceto o tempo de sonicação (180 s) e a adição de KCl 0,15% (m/v). As suspensões sonicadas são centrifugadas e o Hg é determinado no sobrenadante por FI-CV AAS. A validação da metodologia foi feita com CRMs: PACS-2, MESS-3 (NRCC); Buffalo River (NIST 8704), Montana Soil (NIST 2710) e RS-3 (não certificada). Os parâmetros de mérito do método são: massa característica de 25 pg; LD (3s) de 0,2 µg l–1; LQ (10s) de 0,012 µg g–1 (800 µl de solução obtida de 1 g de amostra em 20 ml de suspensão). Aplicou-se a metodologia à análise de amostras reais (solo, sedimentos fluvial e marinho), as quais também foram preparadas com digestão ácida (85 °C durante 3 h) em mistura oxidante (K2S2O8 1 a 2% (m/v) e HNO3 30% (v/v)). Concentrações concordantes foram obtidas. Utilizou-se calibração externa e, quando necessário, ajuste de matriz com KCl ou K2S2O8. Para investigar a extração de Hg orgânico utilizando ultra-som, adicionou-se MeHg aos CRMs. Aproximadamente 5% do MeHg adicionado transformam-se em Hg2+ pelo método proposto, enquanto que chega a 100% quando a amostra é digerida. Assim, propõe-se uma especiação química semiquantitativa entre Hg inorgânico e orgânico, pois o Hg orgânico pode ser obtido pela diferença entre Hg total (determinado pela digestão) e Hg inorgânico (determinado pelo método proposto).
|
25 |
Contribuição para o conhecimento de aspectos clínicos e epidemiológicos da leishmaniose tegumentar americana em Pernambuco: avaliação do uso associado de método de coleta não invasivo e a técnica de PCR, para o diagnóstico da doençaBRITO, Maria Edileuza Felinto de 31 January 2013 (has links)
Submitted by Amanda Silva (amanda.osilva2@ufpe.br) on 2015-03-13T12:24:03Z
No. of bitstreams: 2
TESE Maria Edileuza Felinto de Brito.pdf: 11234347 bytes, checksum: 59279dc5f2f890ab0282f55e2fce09d8 (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-13T12:24:03Z (GMT). No. of bitstreams: 2
TESE Maria Edileuza Felinto de Brito.pdf: 11234347 bytes, checksum: 59279dc5f2f890ab0282f55e2fce09d8 (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2013 / A leishmaniose tegumentar americana (LTA) é uma doença complexa com características clínicas e epidemiológicas que podem variar em cada região. Devido ao seu caráter focal é imprescindível a compreensão da dinâmica da doença em nível local assim como a disponibilidade de métodos de diagnóstico efetivos para a implementação de estratégias de controle e prevenção. A definição de caso é feita através de exames clínicos associados aos dados epidemiológicos e exames laboratoriais. O diagnóstico clínico da LTA é difícil, por assemelhar-se a outras doenças dermatológicas. A confirmação laboratorial baseia-se em análises parasitológicas, imunológicas e moleculares. Um dos pontos críticos do diagnóstico é a coleta das amostras para análise, que emprega métodos invasivos, de difícil operacionalização e desconfortáveis para os pacientes. O estudo propõe avaliar um método de coleta de amostras não invasivo em pacientes de área endêmica em Pernambuco, Brasil para o diagnóstico da LTA. A análise da literatura mostra que a doença é endêmica em todas as regiões geográficas do Estado com maior prevalência na Mata Atlântica ocorrendo surtos esporádicos ocasionais nessa região e no Agreste, disseminando-se para outras áreas e com o aumento da incidência em todo o estado; o principal agente etiológico da LTA em Pernambuco é a Leishmania (Viannia) braziliensis; diversas espécies de flebotomíneos vetores são amplamente distribuídas em todo o território do estado, predominando Lutzomyia whitmani no intra e peridomicílio e L. complexa, L. choti e L. sordelli em remanescentes florestais; roedores silvestres e comensais participam no ciclo de manutenção e transmissão da LTA em Pernambuco. De transmissão vetorial, a LTA também pode ser adquirida como acidente ocupacional pela contaminação com material das lesões dos pacientes e manejo de animais e/ou cultura no laboratório. Dois casos de acidentes ocupacionais por Leishmania spp. foram diagnosticados através de PCR a partir de amostras coletadas por swab, método não invasivo. Estas ocorrências comprovam o potencial de risco em ambiente de laboratório e campo, com a necessidade de rígidos procedimentos de biossegurança nas rotinas diárias. Comparando os resultados das análises em amostras de material de lesões cutâneas de pacientes foi observado que apesar de considerado padrão ouro, apenas 70,6% dos pacientes foram positivos pelo método direto. Pela técnica de PCR tendo como alvo kDNA de minicírculos de Leishmania (Viannia) foi observada uma positividade de 79,5%. A análise estatística para comparação do desempenho das técnicas de coleta de amostras pareadas por swab e biópsia para o diagnóstico da LTA por PCR revelou que a coleta por swab é uma alternativa válida. Os resultados permitem concluir que pela simplicidade da coleta de amostra por swab, associada à alta sensibilidade e especificidade da PCR, o procedimento constitui uma importante contribuição para aperfeiçoamento do diagnóstico e para o sucesso do controle da LTA em áreas endêmicas.
|
26 |
\"Validação da metodologia analítica para a determinação do diclofenaco sódico em amostras de esgoto da estação de tratamento da cidade de Araraquara-SP\" / \"Validation of an analytical methodology to the determination of sodium diclofenac in slurry samples from the water treatment station of Araraquara-SP\"Keila Angélica Peron 26 March 2007 (has links)
Os resíduos de fármacos presentes em matrizes ambientais têm sido foco em pesquisas no mundo todo. Este tema tem sido bastante discutido devido ao fato de que fármacos são freqüentemente encontrados em efluentes de estações de tratamento de esgotos (ETE´s), águas de abastecimento público e em outras matrizes ambientais, tais como solos, sedimentos e águas naturais em concentrações na faixa de µg L-1 e ng L-1. A grande preocupação da presença de resíduos de fármacos na água são os potenciais efeitos adversos para a saúde humana, animal e de organismos aquáticos. Neste trabalho estudou-se o diclofenaco sódico, por ser um dos antiinflamatórios mais prescritos pelos médicos. O método utilizado para a extração do diclofenaco sódico de amostras de efluentes domésticos da ETE de Araraquara-SP foi à extração em fase sólida, e subseqüentemente a determinação por cromatografia líquida de alta eficiência com detector UV. O método foi validado e a recuperação foi de 94-105%. Constatou-se a presença do diclofenaco sódico nas amostras do efluente doméstico da cidade de Araraquara-SP antes e após o tratamento e as concentrações foram 2,12 e 3,52 µg L-1 na coleta feita em março e 18,0 e 22,0µg L-1 na coleta feita em setembro. / The pharmacos residues that are present in the environmental matrices has been a focus of research all over the world. This subject has been discussed because the fact that pharmacos are frequently found in effluents of sewage treatment plants (STPs), public water supply and in others environmental matrices, such as the soil, sediments and water springs in concentrations between µg L-1 and ng L-1. The biggest concern of pharmacos residues in the water are the adverse effects for the human health and the other species too. So, in this research the sodium diclofenac was studied for being the most prescribed anti-inflammatory by the doctors. The method used for the extraction of the sodium diclofenac of samples from the domestic effluent at STP-Araraquara (SP) was the extraction in solid phase, and subsequently the determination by liquid chromatography of high efficiency with UV detector. The method was validated and the recovery was of 94 to 105%. The results of the research have shown the presence of sodium diclofenac in the samples of Araraquara\'s domestic effluent before and after the treatment and the concentrations were 2,12 and 3,52 µg L-1 in the collection made in March and 18,0 and 22,0µg L-1 in the collection made in September.
|
27 |
Refinamento de estruturas cristalinas por difração de raios-x pelo método de mínimos quadrados utilizando dados de amostras policristalinas. / Refinement of crystal structures by x-ray diffraction using the method of least squares and data from polycrystalline samples.Carlos Alberto de Simone 11 March 1983 (has links)
A estrutura da florencita foi refinada pelo método de mínimos quadrados, utilizando dados experimentais obtidos através do método de Debye-Scherrer. A coleta dos dados das intensidades integradas foi feita através da leitura do difratograma de pó por um microdensitômetro óptico automático, e empregando métodos de análise numérica para fazer a integração da função (2θ,Y), tabelada a pontos eqüidistantes. Foram observados 14 picos de difração e as reflexões que se superpunham contribuindo para as intensidades dos picos foram identificadas e suas contribuições levadas em conta através de seus fatores de multiplicidade. O refinamento foi feito com o programa POWLS (Powder Least Squares) e inicialmente foram fornecidos os parâmetros posicionais dos átomos da Goyazita, que é isomorfa com a florencita. As intensidades observadas foram corrigidas pelos fatores de Lorentz-polarização e adsorção. O índice de discordância R atingido para os 14 picos de difração observados foi de 0.097. A fórmula molecular da florencita é CeAl3(PO4)2(OH)6. O composto cristaliza no sistema hexagonal com parâmetros de rede ao=6.96Å co=16.33Å α= β = 90° γ=120° V=685.07޵. O grupo espacial é R3m com Z=3 e densidade calculada igual a 3.67g.cm-3. / The crystal structure of the florencita was refined by least squares using experimental data obtained with the Debye-Scherrer method. An automatic optical microdensitometer was used for the data collection from powder difractogram and numerical analysis methods for the integration of the function (2θ,Y) which is tabulated at equidistant points. 14 diffraction peaks were observed, reflections which superpose contributing to the same peak were identified and their contributions were taken in account using multiplicity factors. The program POWLS (Powder Least Squares) was used for the refinement and initially the positional parameters of the atoms of the Goyazite, which is isomorfous with the florencita were used. Intensities were corrected for the Lorentz, polarization and absorption factors. The final R factor for the 14 peaks was of 0.097. The molecular formula of the florencitais CeAl3(PO4)2(OH)6. It crystallizes in the hexagonal system, space group R3m with cell ao=6.96Å co=16.33Å α= β = 90° γ=120° V=685.07޵.
|
28 |
Espécies de arsênio em moluscos bivalves determinadas por LC-ICP-MS E LC-CVG-ICP-MS após extração assistida por microondasSantos, Clarissa Marques Moreira dos 05 March 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work, the aim of this study is to evaluate sample preparation procedures and
liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS) and LC
coupled to chemical vapor generation (CVG) and ICP-MS (LC-CVG-ICP-MS) for
identification and quantification of As species in mollusks collected in BTS. Conditions
related to As species extraction were assessed with the use of microwave assisted extraction
(MAE) and ultrasound-assisted extraction (UAE). The influence of the main parameters
involved in extraction of As species such as the type and concentration of extraction solution,
sample mass, temperature and extraction time were evaluated. The extraction was possible
by using water at 80 °C (0.2 g sample and 6 mL of w ater) for 6 min using MAE. For the
chromatographic separation the type of mobile phase [(NH4)2CO3 and (NH4)2HPO4]
concentration (1 to 20 mmol L-1), pH (5.0 to 9.0), flow rate (1.05 to 1.45 mL min-1) and elution
mode (isocratic and gradient) were evaluated. The volume of sample injected into the
chromatograph was fixed to 200 μL. For the separation of As species an anion exchange
column (Hamilton PRP-X100, 250 x 4.1 mm) was used. Six As species were detected in the
mollusks being identified arsenobetaine (AsB), As(III), dimethylarsenic acid (DMA) and ρ-
arsanilic acid (ρ-ASA). The best separation of the As species was obtained by gradient
elution mode and using the following program: 0 to 1.4 min using 6 mmol L-1 (NH4)2HPO4 to
1.4 to 2.7 min using 20 mmol L-1 (NH4)2CO3 and 2.7 to 15 min using 6 mmol L-1 (NH4)2HPO4).
The mobile phase flow rate was set at 1.25 mL min-1. CVG parameters were evaluated and
the concentrations of NaBH4 and HCl, and carrier gas flow rate were set to 1.0% (m/v) 1.0
mol L-1 and 1.15 L min-1, respectively. The extraction procedures and determination of total
As were evaluated using certified reference materials BCR 627 (Tuna Fish Tissue), DORM-2
(Dogfish Muscle) and NIST 1566b (Oyster tissue). The agreement of the results obtained
was 95 ± 3 to 101 ± 5%, respectively. The sum of the concentrations of As species
determined by LC-ICP-MS and the total As concentration in digested samples and extracts
measured, determined by ICP OES were also in good agreement on a confidence level of
95% (Student t-Test). The developed methods by employing the LC-ICP-MS and LC-CVGICP-
MS for As speciation analyses in bivalves mollusks are considered suitable. / Neste trabalho foi avaliado o preparo da amostra e o uso da cromatografia a líquido
acoplada à espectrometria de massa com plasma indutivamente acoplado (LC-ICP-MS) e
LC acoplado ao sistema de geração química de vapor (CVG) e ICP-MS para a identificação
e quantificação das espécies de As presentes em tecidos de moluscos bivalves. Condições
relacionadas à extração das espécies de As foram avaliadas com o emprego de extração
assistida por micro-ondas (MAE) e ultrassom (UAE). A influência dos principais parâmetros
envolvidos na extração das espécies de As, como o tipo e concentração da solução
extratora, massa de amostra, temperatura e o tempo de extração por MAE e o tempo de
sonicação por US foram avaliados. Extração de As foi possível usando água a 80 °C (0,2 g
de amostra e 6 mL de água) durante 6 min com MAE. Para a separação cromatográfica
foram avaliados o tipo de fase móvel [(NH4)2CO3 e (NH4)2HPO4], a concentração (1 a 20
mmol L-1), o pH (5,0 a 9,0), a vazão (1,05 a 1,45 mL min-1) e o modo de eluição (isocrático e
gradiente). O volume de amostra injetada no cromatógrafo foi fixado em 200 μL. Para a
separação das espécies de As foi utilizada uma coluna de troca aniônica (Hamilton PRPX100,
250 x 4,1 mm). Foram detectadas seis espécies de As nos moluscos, sendo
identificadas somente a arsenobetaína (AsB), o As(III), o dimetilarsênio (DMA) e o ácido ρ-
arsanílico (ρ-ASA). A melhor separação das espécies de As foi obtida por eluição gradiente
utilizando as seguintes condições: 0 a 1,4 min empregando 6 mmol L-1 de (NH4)2HPO4, 1,4 a
2,7 min empregando 20 mmol L-1 de (NH4)2CO3 e 2,7 a 15 min utilizando 6 mmol L-1 de
(NH4)2HPO4. A vazão da fase móvel foi fixada em 1,25 mL min-1. Os parâmetros de CVG
avaliados foram a concentração de NaBH4 e HCl e a vazão do gás de arraste, as quais
foram fixadas em 1,0 % (m/v), 1,0 mol L-1 e 1,15 L min-1, respectivamente. Os procedimentos
de extração e determinação de As total foram avaliados utilizando os materiais de referência
certificados BCR 627 (Tuna Fish Tissue), DORM-2 (Dogfish Muscle) e NIST 1566b (Oyster
tissue). A concordância entre os resultados obtidos foi de 95 ± 3 a 101 ± 5%,
respectivamente. Os valores entre a soma das concentrações das espécies de As obtidos
por LC-ICP-MS e As total nos digeridos e extratos obtidos, determinado por ICP OES
também foram concordantes em um nível de confiança de 95% (Teste t-Student). Desta
forma, o método desenvolvido empregando LC-ICP-MS e LC-CVG-ICP-MS foi considerado
adequado para determinação de espécies de As em moluscos bivalves.
|
29 |
Desenvolvimento de método para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se em sangue por espectrometria de massas com fonte de plasma acoplado indutivamente (ICP-MS) utilizando diluição das amostras em meio alcalino / Development of a high-throughput method for assessment of Ag, As, Cd, Co, Mn, Ni, Pb and Se in blood samples by inductively coupled plasma mass spectrometry (ICP-MS)Nunes, Juliana Andrade 07 August 2009 (has links)
A técnica analítica mais utilizada para o monitoramento de exposição a metais tóxicos ou para avaliação de deficiência a elementos essenciais é a espectrometria de absorção atômica chama (FAAS) ou com forno de grafite (GF AAS). Entretanto, cada vez mais os laboratórios de pesquisa na área clínica estão mudando seus métodos de análise, baseados nestas técnicas, para a utilização da espectrometria de massas com plasma acoplado (ICP-MS). Isso vem acontecendo porque o ICP-MS permite a determinação de elementos químicos, em diversas matrizes, numa ampla faixa de concentração (ng L-1 a mg L-1), além de possibilitar alta rapidez de análise, capacidade multielementar e limites de detecção menores que outras técnicas analíticas. Uma das principais características do método a ser utilizado para a análise de elementos químicos em rotina por ICP-MS é que ele seja rápido, com o mínimo de manipulação da amostra. Neste sentido, métodos que propõem a análise direta de amostra são mais atrativos. Todavia, ainda é limitado o número de métodos que propõem análise direta de fluidos biológicos por ICP-MS. Neste sentido, o presente trabalho teve como objetivo o desenvolvimento de um método para análise direta de sangue por ICP-MS para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se. Para isso, amostras de sangue (200 µL) foram misturadas com 500 µL de hidróxido de tetrametilamônio (TMAH) (10% v/v) e incubadas por 10 minutos. Posteriormente, a solução resultante foi diluída para 10 mL com uma solução contendo 0,05% m/v EDTA; 0,005% v/v Triton® X-100. Em seguida, as amostras foram analisadas diretamente por ICP-MS (ELAN DRC II). Ródio (Rh) foi usado como padrão interno e a calibração das amostras foi feita por meio de ajuste de matriz com sangue base ovino. Os limites de detecção (LD) do método foram de 0,008; 0,02; 0,004; 0,009; 0,003; 0,09; 0,04; 0,1 µg L-1 para Ag, As, Cd, Co, Mn, Ni, Pb and Se, respectivamente. A validação dos resultados foi realizada com análise de um material de referência de sangue do Programa de Proficiência do Institut National de Santé Publique du Quebec, no Canadá. Validação adicional foi obtida pela comparação dos resultados obtidos pela análise de 20 amostras de sangue pelo método proposto e pela técnica de GF AAS. O método foi também comparado a outros dois existentes na literatura e comumente utilizados em laboratórios dos Estados Unidos e Suécia, apresentando limites de detecção comparáveis ou melhores e melhores exatidão e precisão. / The most used analytical technique for monitoring the exposure to toxic metals or for the assessment of the deficiency of essentials elements is the atomic absorption spectrometry with flame (FAAS) or graphite furnace (GF AAS). However, more and more clinical laboratories are changing their methods of analysis, based on this technique, to methods using inductively coupled plasma-mass spectrometry (ICP-MS). It occurs because ICP-MS allows the determination of chemical elements in various types of samples, at concentrations in a wide linear range (ng L-1 to mg L-1), providing high-throughput analysis with multielemental capability with lower detection limits. However, for routine porpuses the method of choice must be fast with minimal sample manipulation.On the other hand, the number of methods proposing direct introduction of biological fluids to the ICP-MS are still limited. This work aimed the development of a method for the direct analysis of blood samples by ICP-MS for the determination of Ag, As, Cd, Co, Mn, Ni, Pb and Se. For this, blood samples (200 L) were mixed with 500 L of tetramethylammonium hydroxide (TMAH) (10% v/v) and left at room temperature during 10 minutes. Subsequently, the resulting solution was diluted to 10 mL with a solution containing 0.05% m/v EDTA + 0005% v / v Triton ® X-100. Thus the samples were analyzed directly by ICP-MS (ELAN DRC II). Rhodium (Rh) was used as internal standard with matrix matching calibration. The method detection limits were: 0.008, 0.02, 0.004, 0.009, 0.003, 0.09, 0.04, 0.1 µg L-1 for Ag, As, Cd, Co, Mn, Ni , Pb, and Se respectively. Method validation was acquired with the analysis of blood reference material provided by the Institut National de Santé Publique du Quebec, Canada. Furthermore, for additional validation 20 ordinary blood samples were analyzed by the proposed method and by GF AAS. The method was also compared with two existing methods in the literature and commonly used in laboratories in the United States and Sweden where comparable or better detection limits and better accuracy and precision were obtained.
|
30 |
Desenvolvimento de método para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se em sangue por espectrometria de massas com fonte de plasma acoplado indutivamente (ICP-MS) utilizando diluição das amostras em meio alcalino / Development of a high-throughput method for assessment of Ag, As, Cd, Co, Mn, Ni, Pb and Se in blood samples by inductively coupled plasma mass spectrometry (ICP-MS)Juliana Andrade Nunes 07 August 2009 (has links)
A técnica analítica mais utilizada para o monitoramento de exposição a metais tóxicos ou para avaliação de deficiência a elementos essenciais é a espectrometria de absorção atômica chama (FAAS) ou com forno de grafite (GF AAS). Entretanto, cada vez mais os laboratórios de pesquisa na área clínica estão mudando seus métodos de análise, baseados nestas técnicas, para a utilização da espectrometria de massas com plasma acoplado (ICP-MS). Isso vem acontecendo porque o ICP-MS permite a determinação de elementos químicos, em diversas matrizes, numa ampla faixa de concentração (ng L-1 a mg L-1), além de possibilitar alta rapidez de análise, capacidade multielementar e limites de detecção menores que outras técnicas analíticas. Uma das principais características do método a ser utilizado para a análise de elementos químicos em rotina por ICP-MS é que ele seja rápido, com o mínimo de manipulação da amostra. Neste sentido, métodos que propõem a análise direta de amostra são mais atrativos. Todavia, ainda é limitado o número de métodos que propõem análise direta de fluidos biológicos por ICP-MS. Neste sentido, o presente trabalho teve como objetivo o desenvolvimento de um método para análise direta de sangue por ICP-MS para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se. Para isso, amostras de sangue (200 µL) foram misturadas com 500 µL de hidróxido de tetrametilamônio (TMAH) (10% v/v) e incubadas por 10 minutos. Posteriormente, a solução resultante foi diluída para 10 mL com uma solução contendo 0,05% m/v EDTA; 0,005% v/v Triton® X-100. Em seguida, as amostras foram analisadas diretamente por ICP-MS (ELAN DRC II). Ródio (Rh) foi usado como padrão interno e a calibração das amostras foi feita por meio de ajuste de matriz com sangue base ovino. Os limites de detecção (LD) do método foram de 0,008; 0,02; 0,004; 0,009; 0,003; 0,09; 0,04; 0,1 µg L-1 para Ag, As, Cd, Co, Mn, Ni, Pb and Se, respectivamente. A validação dos resultados foi realizada com análise de um material de referência de sangue do Programa de Proficiência do Institut National de Santé Publique du Quebec, no Canadá. Validação adicional foi obtida pela comparação dos resultados obtidos pela análise de 20 amostras de sangue pelo método proposto e pela técnica de GF AAS. O método foi também comparado a outros dois existentes na literatura e comumente utilizados em laboratórios dos Estados Unidos e Suécia, apresentando limites de detecção comparáveis ou melhores e melhores exatidão e precisão. / The most used analytical technique for monitoring the exposure to toxic metals or for the assessment of the deficiency of essentials elements is the atomic absorption spectrometry with flame (FAAS) or graphite furnace (GF AAS). However, more and more clinical laboratories are changing their methods of analysis, based on this technique, to methods using inductively coupled plasma-mass spectrometry (ICP-MS). It occurs because ICP-MS allows the determination of chemical elements in various types of samples, at concentrations in a wide linear range (ng L-1 to mg L-1), providing high-throughput analysis with multielemental capability with lower detection limits. However, for routine porpuses the method of choice must be fast with minimal sample manipulation.On the other hand, the number of methods proposing direct introduction of biological fluids to the ICP-MS are still limited. This work aimed the development of a method for the direct analysis of blood samples by ICP-MS for the determination of Ag, As, Cd, Co, Mn, Ni, Pb and Se. For this, blood samples (200 L) were mixed with 500 L of tetramethylammonium hydroxide (TMAH) (10% v/v) and left at room temperature during 10 minutes. Subsequently, the resulting solution was diluted to 10 mL with a solution containing 0.05% m/v EDTA + 0005% v / v Triton ® X-100. Thus the samples were analyzed directly by ICP-MS (ELAN DRC II). Rhodium (Rh) was used as internal standard with matrix matching calibration. The method detection limits were: 0.008, 0.02, 0.004, 0.009, 0.003, 0.09, 0.04, 0.1 µg L-1 for Ag, As, Cd, Co, Mn, Ni , Pb, and Se respectively. Method validation was acquired with the analysis of blood reference material provided by the Institut National de Santé Publique du Quebec, Canada. Furthermore, for additional validation 20 ordinary blood samples were analyzed by the proposed method and by GF AAS. The method was also compared with two existing methods in the literature and commonly used in laboratories in the United States and Sweden where comparable or better detection limits and better accuracy and precision were obtained.
|
Page generated in 0.0691 seconds