• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 190
  • 3
  • 2
  • Tagged with
  • 198
  • 76
  • 53
  • 38
  • 32
  • 31
  • 22
  • 20
  • 19
  • 19
  • 19
  • 18
  • 18
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Atividade moluscicida em Biomphalaria glabrata Say: revisão e avaliação do látex de Euphorbia umbellata (Pax) Bruyns (Euphorbiaceae) / Molluscicidal activity in Biomphalaria glabrata Say: review and evaluation of Euphorbia umbellata latex (Pax) Bruyns (Euphorbiaceae)

PEREIRA, Luciana Patrícia Lima Alves 06 April 2013 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-09-05T18:52:30Z No. of bitstreams: 1 LucianaAlves.pdf: 955999 bytes, checksum: 6c7aeb0334f4a832a4ef4f5804f697cc (MD5) / Made available in DSpace on 2017-09-05T18:52:30Z (GMT). No. of bitstreams: 1 LucianaAlves.pdf: 955999 bytes, checksum: 6c7aeb0334f4a832a4ef4f5804f697cc (MD5) Previous issue date: 2013-04-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Schistosomiasis is a parasitic disease caused by Schistosoma mansoni Sambon, that needs freshwater snails to complete their cycle. In Brazil, this disease affects thousands of people each year, being the Maranhão one of the states of higher occurrence. According to the World Health Organization, one of the measures need to reduce this disease is the control snails hosts through of the use of products known as molluscicides. Despite of the effectiveness of the use of niclosamide in this control, the high cost and environmental problems arising of this use has stimulated the search for new molluscicides safer, especially those of plant origin. Thus, this study aimed to perform a review of the plants and of the compounds of plant origin tested for the molluscicidal activity in Biomphalaria glabrata Say and analyze the chemical composition, the molluscicidal activity and toxicity of the latex of Euphorbia umbellata (Pax) Bruyns in adult fish species Danio rerio Hamilton-Buchanan. This dissertation was divided into two chapters. The chapter 1 consists of a review of the scientific studies which showed that extracts, fractions and compounds obtained of 200 plant species have already been tested by their molluscicidal activity and that 60, 75 and 95% of these, respectively, were actives according with the criteria established in this work. The chapter 2 aimed to perform a phytochemical screening and tests of toxicity in B. glabrata and D. rerio with the latex of E. umbellata. Phytochemical screening and evaluation of molluscicidal activity of the latex E. umbellata, cultivated plant in the state of Maranhão, revealed the presence of triterpenes and coumarins and high toxicity to B. glabrata. Experiments with D. rerio showed low toxicity of the latex. The results obtained showed the potential of natural products from plants, mainly the latex of E. umbellata, to produce molluscicidal agents that could be used to control of the schistosomiasis. It is expected that this work will contribute to the reduction in the number of cases of this disease in the state of Maranhão and for the preservation of plant studied. / A esquistossomose mansônica é uma doença parasitária causada pelo Schistosoma mansoni Sambon, que necessita de caramujos de águas doces para completar o seu ciclo. No Brasil, esta doença acomete milhares de pessoas anualmente, sendo o Maranhão um dos estados de maior ocorrência. Segundo a Organização Mundial de Saúde, uma das medidas necessárias para reduzir esta parasitose é o controle dos moluscos hospedeiros através do uso de produtos conhecidos como moluscicidas. Apesar do reconhecimento da eficácia do uso do produto químico niclosamida nesse controle, o alto custo e problemas ambientais decorrentes desta utilização vêm estimulando a pesquisa de novos moluscicidas mais seguros, destacando-se os de origem vegetal. Dessa forma, o presente trabalho objetivou realizar um levantamento das plantas e dos compostos de origem vegetal com estudos de atividade moluscicida em Biomphalaria glabrata Say bem como analisar a composição química, a atividade moluscicida e a toxicidade do látex de Euphorbia umbellata (Pax) Bruyns em peixes adultos da espécie Danio rerio Hamilton-Buchanan. Esta dissertação foi dividida em dois capítulos. O capítulo 1 consiste no artigo de revisão de literatura, onde foi possível verificar que extratos, frações e substâncias químicas de 200 espécies vegetais já foram avaliados quanto a esta atividade e que, 60, 75 e 95% destes, respectivamente, mostraram-se ativos segundo os critérios estabelecidos no trabalho. O capítulo 2 objetivou realizar uma triagem fitoquímica e testes de toxicidade em B. glabrata e D. rerio com o látex de E. umbellata. Prospecção fitoquímica e avaliação da atividade moluscicida do látex E. umbellata, planta cultivada no estado do Maranhão, revelaram a presença de triterpenos e cumarinas e a alta toxicidade contra B. glabrata. Os experimentos com D. rerio demonstraram baixa ictiotoxicidade do látex em estudo. Os resultados obtidos evidenciam o potencial dos produtos naturais de plantas, em especial do látex de E. umbellata, para a obtenção de agentes moluscicidas que possam ser empregados no controle da esquistossomose mansônica. Além do declínio no número de casos desta doença no estado do Maranhão, pretende-se que este trabalho contribua para a conservação da espécie vegetal estudada.
52

Emprego de sistema em fluxo a altas temperatura e pressão no preparo de amostras de leite e sangue de bovinos / Use of high temperature and high pressure flow system for bovine milk and blood sample preparation

Barros, Allen Lopes de 17 October 2008 (has links)
No presente trabalho, um sistema em fluxo operando sob altas temperaturas e pressão foi avaliado, com o objetivo de solubilizar amostras de sucos, leite e sangue de bovinos para a determinação de constituintes inorgânicos. O sistema emprega uma bomba de alta pressão utilizada em cromatografia líquida para o transporte dos líquidos através de um tubo capilar metálico aquecido e de um capilar restritor de menor diâmetro interno, com a finalidade de se obter digeridos ácidos das amostras em estudo. A eficiência da digestão foi avaliada a partir da determinação do carbono residual, realizada por espectrometria de emissão óptica com plasma de argônio indutivamente acoplado. Espectrometria de absorção atômica com chama e geração de hidretos voláteis foi usada para as determinações de selênio. Foram exploradas diferentes configurações relacionadas ao sistema, tais como emprego de um capilar restritor e da bobina digestora construída em aço inoxidável com diferentes comprimentos, pressões de trabalho e formas de introdução das amostras, além da proposta alternativa para a inserção de amostras que permitiu contornar a inconveniente precipitação das proteínas antes da entrada das amostras no sistema. Para isso, configuração que possibilitou mistura entre a amostra e os reagentes por confluência no interior do sistema sem prévia mistura foi avaliada. Os resultados indicaram a viabilidade do sistema, com a redução do carbono residual em mais de 60 %. Porém, problemas relacionados a perdas de elementos por volatilização necessitam ser contornados. / A flow injection system, operated under high temperature and high pressure conditions has been evaluated concerning the dissolution of fruit juices and samples of bovine milk and blood for the determination of inorganic constituents. In this system, a high pressure liquid chromatography pump was used for the transportation of liquid samples through a stainless steel heated capillary and finally through a restrictor capillary, which has a shorter inner diameter, so that the digestion of the samples could be attained. The residual carbon contents were determined by inductively coupled plasma atomic emission spectrometry. Hydride generation flame atomic absorption spectrometry was used for selenium determinations. Different configurations for the flow system were evaluated, such as variable lengths for the restrictor and digestion capillaries. Different working pressures as well as different ways for the sample introduction were tried out, being reached an alternative that avoided the precipitation of proteins before the introduction of the samples in the system. For this purpose, a configuration in which the contact between sample and reagents occurs inside the system, with no previous mixture, was evaluated. The results indicated the viability of the system which used the confluence configuration. Although digestion efficiency of 60 % was observed for milk samples, problems related to volatilization have to be circumvented.
53

Estudo sobre a determinação de paládio em amostras biológicas pelo método de análise por ativação com nêutrons / Study on the determination of palladium in biological samples for the method of analysis for activation with nêutrons

Cavalcante, Cassio Queiroz 12 April 2007 (has links)
O paládio é um dos elementos do grupo da platina presente em baixos teores na natureza. Nos últimos anos com o crescente uso deste elemento nos catalisadores automotivos e nas investigações para o desenvolvimento de drogas anti-tumorais, as suas determinações tornaram-se de grande interesse. No presente trabalho foi feito um estudo sobre a determinação de paládio em amostras biológicas e materiais de referência pelo método de análise por ativação puramente instrumental com nêutrons térmicos (INAA) e epitérmicos (ENAA) separadamente, bem como pela ENAA após separação do paládio por meio das técnicas de extração com solventes e de extração em uma coluna de fase sólida. As amostras analisadas no presente estudo foram: material de referência BCR 723 – Palladium, Platinum and Rhodium in road dust, material catalisador automotivo do teste de proficiência do CCQM-P63 e amostras de tecido bovino contendo Pd preparadas no laboratório. As irradiações das amostras e padrão para INAA e ENAA foram realizadas no reator IEA-R1 sob fluxo de nêutrons térmicos da ordem de 4 x 10 12 n cm-2 s-1 e por um período de 4 h nas irradiações térmicas e de 16 h nas epitérmicas. Depois de adequados tempos de decaimento as medições das atividades gama induzidas das amostras e padrões foram feitas usando um espectrômetro de raios gama constituído de um detector de Ge hiperpuro e eletrônica associada. A concentração de paládio foi calculada pelo método comparativo. O paládio foi medido pelo pico de 88,0 keV do 109Pd localizado numa região do espectro de baixa energia onde ocorre a interferência de picos de raios X, da radiação de freiamento e do efeito Compton do 24Na. A pré-separação do paládio dos elementos interferentes pelo método de extração com solventes foi feita por meio da extração do complexo formado entre o paládio e a dimetilglioxima em clorofórmio. O método de separação por meio da extração em fase sólida consistiu na retenção do paládio em uma coluna de fase sólida de octadecilsilano, contendo complexante N,N-dietil-N’-benzoil tiouréia (DEBT) adsorvido e em seguida fazendo a eluição de paládio com etanol. Alíquotas das soluções resultantes da préseparação, livres de elementos interferentes, foram pipetadas em cápsulas de polietileno e submetidas à ENAA. A comparação entre os resultados de paládio obtidos por diferentes procedimentos de ativação com nêutrons indicou uma boa concordância e uma boa precisão com desvios padrão relativos variando de 2 a 14%. Os rendimentos de recuperação na pré-separação de paládio variaram de 70,9 a 97,7 % e estes resultados dependem do tipo de matriz e da técnica de pré-separação aplicada. Os valores de limite de detecção obtidos para análise do tecido muscular bovino foram de 11,0 e 0,4 μg g-1 pelos métodos de INAA e ENAA, respectivamente. Para o caso do material de referência BCR-723 foram obtidos limites de 24,0 e 1,7 μg g-1, respectivamente na INAA e ENAA e estes resultados indicaram que o limite de detecção depende do tipo de matriz analisada. A irradiação com nêutrons epitérmicos permitiu aumento da sensibilidade devido à redução do problema de interferência e além disso a aplicação da separação prévia do paládio seguida de ENAA proporcionou um aumento da sensibilidade quando comparada com ENAA purament e instrumental. / Palladium is one of platinum group elements present in the nature at very low concentrations. However with the use of this element in the automobile catalyzers Pd became a new pollutant. Besides, Pd has been studied in the preparation of new antitumour drugs. Consequently, there is a need to determine Pd concentrations in biological and environmental samples. This study presents palladium results obtained in the analysis of biological samples and reference materials using instrumental thermal and epithermal neutron activation analysis (INAA and ENAA). The solvent extraction and solid phase extraction separation methods were also applied before ENAA. The samples analyzed in this study were, reference material BCR 723–Palladium, Platinium and Rhodium in road dust, CCQM-P63 automotive catalyst material of the Proficiency Test and bovine tissue samples containing palladium prepared in the laboratory. Samples and palladium synthetic standard were irradiated at the IEA-R1 nuclear research reactor under thermal neutron flux of about 4 x 10 12 n cm-2 s-1, during a period of 4 and 16 h for INAA and ENAA, respectively. The induced gamma activity of 109Pd to the sample and standard was measured using a hyperpure Ge detector coupled to a gamma ray spectrometer. The palladium concentration was calculated by comparative method. The gamma ray energy of 109Pd radioisotope measured was of 88.0 keV, located in a spectrum region of low energy where occurs the interference of X rays, “bremsstrahlung" radiations, as well as Compton effect of 24Na. The pre-separation of palladium from interfering elements by solvent extraction was performed using dimethylglyoxime complexant and chloroform as diluent. In the case of the pre separation procedure using solid reversed phase column, the palladium was retained using N,N-diethyl-N’-benzoyl thiourea complexant and eluted using ethanol. Aliquots of the resulting solutions from the pre-separations, free of interfering elements, were transfered to polyethylene capsules and analyzed by ENAA. Comparisons of palladium results obtained using different procedures of neutron activations analysis showed good agreement and precision. The relative standard deviations of palladium results varied between 2 and 14 %. The recovery yields obtained in the pre-separation procedure varied from 70.9 to 97.7 %, depending on the matrices analyzed and method of separation. Detection limits of 11.0 and 0.4 μg g-1 were obtained in the Pd determination in bovine muscle samples by INAA and ENAA, respectively. For reference material BCR- 723 road dust detection limits of 24.0 and 1.7 μg g-1 were obtained by INAA and ENAA, respectively. These results indicated that the detection limit depends on the matrix type to be analyzed and the epithermal neutron activation allowed high sensitivity for Pd determination due to the reduction of interferences. In regards to palladium determination using pre-separation procedures, the detection limit values indicated that the extraction procedure provides higher sensitivity, when compared to purely instrumental ENAA.
54

Avaliação de estratégias para melhoria da sensibilidade em análises por espectrometria de emissão óptica com plasma induzido por laser / Evaluation of strategies to improve sensitivity in analyzes by laser induced breakdown spectroscopy

Lázaro, Maisa Cristina [UNESP] 09 August 2017 (has links)
Submitted by MAISA CRISTINA LAZARO null (maisalazaro_mcl@hotmail.com) on 2017-09-05T15:09:44Z No. of bitstreams: 1 Dissertação Mestrado_Repositório.pdf: 1448238 bytes, checksum: f02ad2ea0e02cac8044c4645b5fd43f7 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-09-06T16:16:31Z (GMT) No. of bitstreams: 2 lazaro_mc_me_araiq_par.pdf: 540678 bytes, checksum: 2e6053c1e59ea8b435722b01fd52317a (MD5) lazaro_mc_me_araiq_int.pdf: 1448238 bytes, checksum: f02ad2ea0e02cac8044c4645b5fd43f7 (MD5) / Made available in DSpace on 2017-09-06T16:16:31Z (GMT). No. of bitstreams: 2 lazaro_mc_me_araiq_par.pdf: 540678 bytes, checksum: 2e6053c1e59ea8b435722b01fd52317a (MD5) lazaro_mc_me_araiq_int.pdf: 1448238 bytes, checksum: f02ad2ea0e02cac8044c4645b5fd43f7 (MD5) Previous issue date: 2017-08-09 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A espectrometria de emissão óptica em plasma induzido por laser (LIBS) é uma técnica que vem se desenvolvendo cada vez mais para determinações analíticas multielementares, com aplicações em diversas áreas. Possui várias vantagens, como por exemplo, ser uma técnica de análise rápida, minimamente destrutiva e ambientalmente amigável, enquanto que a maior dificuldade está baseada na sua relativa baixa sensibilidade. Muitos estudos têm sido desenvolvidos com a finalidade de melhorar a sensibilidade, porém os aprimoramentos elaborados demandam equipamentos mais sofisticados, aumentando o custo e comprometendo a portabilidade da técnica. O presente trabalho avaliou estratégias simples para melhorar a sensibilidade das medidas em LIBS, permitindo o uso de instrumentos compactos de pulso simples. As estratégias desenvolvidas se baseiam na proposição da introdução de uma etapa simples de pré-tratamento da amostra, capaz de agir na fragilização de estruturas químicas que por consequência levem ao aumento das intensidades de emissão das espécies componentes da amostra. As etapas de pré-tratamentos buscam em sua essencialidade não descaracterizar as vantagens analíticas de LIBS, tais como a simplicidade e a não utilização de reagentes potencialmente tóxicos, além de serem aplicáveis à diversos tipos de amostras. A ação da temperatura sobre a modificação de estruturas químicas foi avaliada utilizando aquecimento em mufla para amostra de material vegetal, solo e liga metálica e em forno de micro-ondas para amostra vegetal. Os tratamentos empregados utilizando aquecimento em mufla resultaram em aumentos nas intensidades de emissão em toda região espectral para todas as amostras avaliadas; para a amostra de folha, material para o qual foram obtidos os melhores resultados, foram verificados aumentos de 47x com relação à área de pico da linha de Ca I em 612,14 nm, além do aparecimento de linhas antes não observadas, como a de Sr II em 407,82 nm. Para a amostra de liga, a área da linha de Fe I em 489,22 nm teve um aumento de 8x e para a amostra de solo, a linha de Na em 588,89 nm, por exemplo, teve seu valor de área aumentado em 4x com a aplicação do tratamento térmico. O aquecimento em micro-ondas forneceu incrementos de intensidade menos pronunciados, comparados ao aquecimento em mufla. Adicionalmente foi avaliada a introdução de fundente à amostra de solo com o intuito de melhorar processos físicos, os quais poderiam culminar em aumento dos processos de emissão dos analitos da amostra, entretanto, esta estratégia não atingiu o objetivo proposto. Por fim, o tratamento térmico em mufla foi aplicado no desenvolvimento de um método para determinação de Sr em material foliar utilizando LIBS. O método desenvolvido apresentou curva analítica linear com coeficiente de correlação igual a 0,997, limite de detecção igual a 4,23 mg kg-1 e limite de quantificação igual a 14,09 mg kg-1. A análise de material de referência certificado foliar pelo método proposto indicou que a concentração de Sr determinada é concordante com o valor certificado a 95% de confiança (test t pareado). / Laser-induced breakdown spectroscopy (LIBS) is an analytical technique in development, increasingly applied for multielemental determinations in several areas. It shows several advantages, such as rapidity, minimally destructive and environmentally friendly, although the greatest difficulty is based on its relatively low sensitivity. Many efforts have been expended to improve LIBS sensitivity, but several proposals require more sophisticated equipment, increasing the cost and compromising the portability of the technique. The present work evaluated simple strategies to improve the sensitivity of LIBS measurements allowing the use of compact single pulse instruments. The proposed strategies are based on a simple sample pretreatment, able to promotes simplification of chemical structures, which could lead to an increase of emission intensities. The proposed pretreatment steps aimed to preserve the interesting LIBS analytical advantages, such as its simplicity and non-use of toxic reagents, and its applicability to several types of samples. Then the temperature action on the simplification of chemical structures was evaluated using conventional muffle oven, for samples of plant leaves, soil and metal alloy. Additionally, microwave oven heating was evaluated for plant leaves. The muffle oven treatments resulted in important increases of the emission intensities for all spectral region of all evaluated samples; for the plant leaves, material for which the best results were observed, the integrated peak area of the Ca I line at 612.14 nm was increased about 47x after the thermic treatment. Moreover, new emission lines, not observed before, such as Sr II line at 407.82 nm, appeared. In the alloy sample, the integrated area of Fe I line at 489.22 nm showed an increase of 8x and in soil sample the Na I line at 588.89 nm, showed an increasing of 4x. The microwave heating provided less pronounced intensity increments compared to the muffle heating. The mixture of the soil sample with chemical modifier was also evaluated in order to improve physical processes, which could lead to an increasing of the emission signals. Nevertheless, this strategy did not reach the expected. Finally, the heat treatment in muffle was applied in the development of a method for determination of Sr in leaf material using LIBS. The developed method presented a linear analytical curve with correlation coefficient of 0.997, limit of detection of 4.23 mg kg -1 and limit of quantification of 14.09 mg kg-1 . Analysis of leaf reference material by the proposed method indicated the determined concentration of Sr is in agreement with the certified value at 95% confidence (paired t-test). / CNPq: 830856/1999-4
55

Letramento, gênero, raça e ocupação no Brasil

Machado-Spence, Nádie Christina Ferreira January 2004 (has links)
O estudo buscou identificar as relações entre letramento/alfabetização e gênero, raça e condições de ocupação no Brasil e diferentes Unidades da Federação, tendo como base empírica os microdados da Pesquisa Nacional por Amostras de Domicílios (PNAD), realizada pelo Instituto Brasileiro de Geografia e Estatística (IBGE) em 2002. O modelo de análise foi elaborado com base nos níveis de letramento propostos por Ferraro (2002) a partir da variável “anos de estudo concluídos com êxito”, incluindo-se o nível 0, que corresponde a quem se declarou sem instrução ou com menos de um ano de estudo. Verificaram-se grandes desigualdades entre as regiões e as Unidades da Federação em termos de sua distribuição pelos diferentes níveis de letramento. Apenas o Distrito Federal e os estados de São Paulo e Rio de Janeiro, da Região Sudeste, e Paraná e Rio Grande do Sul, da Região sul, apresentaram, no nível mais alto de letramento, taxas superiores à do Brasil como um todo. No nível mais alto de letramento (Nível 4 - 11 anos ou mais anos de estudo), as mulheres superam os homens em todos os grupos de idade mais jovens, de 10 a 14 anos até 50 a 54 anos. Apenas nos grupos de idade mais avançada, de 55 ou mais anos, os homens continuam a superar a mulheres nesse nível de letramento Isto indica que, a partir de meados do século XX, foi verificando-se uma inversão histórica do fenômeno da desigualdade em educação, com vantagem, agora, para as mulheres no que se refere a níveis de letramento. A intersecção de raça e gênero revelou que essas duas dimensões se somam e se sobrepõem, mas mantendo cada uma dessas duas dimensões a sua especificidade. Com efeito, em todas as idades, independentemente de qual gênero leve vantagem em termos de letramento, os homens brancos sempre superam os homens negros, da mesma forma que as mulheres brancas sempre levam vantagem em relação às mulheres negras. As variáveis gênero e raça contribuíram também muito para o diagnóstico das desigualdades no estudo do letramento quando analisadas em relação à condição de ocupação das pessoas.
56

Desenvolvimento de métodos analíticos de rotina para análise de grãos de café verde utilizando amostragem sólida por espectrometria de absorção atômica em forno de grafite

Oleszczuk, Nédio January 2008 (has links)
O desenvolvimento de métodos para a determinação de manganês, cobre, cobalto e cádmio em café verde, usando amostragem direta por espectrometria de absorção atômica com forno de grafite, foi o principal objetivo do projeto. A motivação do estudo deveu-se ao fato que poucos elementos são necessários para a determinação da origem do café verde, não necessitando, assim, de técnicas multielementares. Manganês, cobre e cobalto foram escolhidos como elementosteste pois foram significativos em prévias investigações; cádmio foi incluído devido à sua toxicidade. Para a determinação de Mn, Co e Cd foi possível utilizar calibração versus padrões aquosos, enquanto que para a determinação de Cu foi necessário o uso de materiais de referência certificados (CRM). Os limites de detecção foram 0,012, 0,006, 0,004 e 0,001 μg g-1 para Mn, Cu, Co e Cd respectivamente. Vários CRM botânicos e amostras pré-analisadas de café verde foram utilizados na validação do método; espectrometria de emissão ótica por plasma indutivamente acoplado foi usada como método de referência. Não foi observada diferença significativa entre os resultados obtidos com o método proposto e os valores certificados ou determinados independentemente. Sete amostras de café verde brasileiro foram analisadas, porém não foi tentado correlacionar os valores com a origem, já que apenas uma amostra por plantação foi analisada. / A method has been developed for the determination of manganese, copper, cobalt and cadmium in green coffee using direct solid sampling graphite furnace atomic absorption spectrometry. The motivation for the study was that only a few elements might be necessary to determine the origin of green coffee and no multielement technique is necessary. Manganese, copper and cobalt were chosen as test elements as they have been found significant in previous investigations; cadmium was included because of its toxicity. Calibration against aqueous standards could be used for the determination of Mn, Co and Cd, but calibration against solid certified reference materials (CRM) was necessary for the determination of Cu; the limits of detection were 0,012, 0,006, 0,004 and 0,001 μg g-1 for Mn, Cu, Co and Cd respectively. Several botanical CRM and pre-analyzed samples of green coffee were used for method validation; inductively coupled plasma optical emission spectrometry was used as reference method. No significant difference was found between the results obtained with the proposed method and certified or independently determined values. Seven samples of Brazilian green coffee have been analyzed, but no attempt was made to correlate the values with the origin, as only one sample was analyzed for each growing area.
57

Avaliação de métodos analíticos para determinação da composição mineral em derivados de soja empregando técnicas espectrométricas

Barbosa, José Tiago Pereira 04 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-12T17:29:38Z No. of bitstreams: 1 Dissertação José Tiago Pereira Barbosa.pdf: 1750358 bytes, checksum: e01d971ee45a1ab67fd25d7981b87383 (MD5) / Approved for entry into archive by NUBIA OLIVEIRA (nubia.marilia@ufba.br) on 2016-09-12T18:21:30Z (GMT) No. of bitstreams: 1 Dissertação José Tiago Pereira Barbosa.pdf: 1750358 bytes, checksum: e01d971ee45a1ab67fd25d7981b87383 (MD5) / Made available in DSpace on 2016-09-12T18:21:31Z (GMT). No. of bitstreams: 1 Dissertação José Tiago Pereira Barbosa.pdf: 1750358 bytes, checksum: e01d971ee45a1ab67fd25d7981b87383 (MD5) / CAPEs / A proteína texturizada de soja possui alto conteúdo protéico e é usualmente utilizada como alternativa na substituição de uma porção de carne. O objetivo deste trabalho foi avaliar três procedimentos de decomposição úmida, visando determinação multielementar (Ca, K, Mg, P, Cr, Cu, Fe, Mn, Ni e Zn) em amostras de proteína texturizada de soja por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Nos procedimentos usando chapa aquecedora (PC) e bloco digestor (PB) foi utilizada a mistura de HNO3 e H2O2, enquanto que para o procedimento com forno de microondas focalizadas (PF) foi necessária a introdução também de H2SO4. As figuras analíticas de mérito, tais como precisão, limites de detecção (LOD) e quantificação (LOQ) e efeito de matriz, foram avaliadas para os procedimentos propostos. As concentrações de Al, Cd, Co e Pb, encontraram-se abaixo do LOQ dos procedimentos para as amostras. A exatidão foi verificada com material de referência certificado e por comparação com método de referência da AOAC. Além disso, foi otimizado um sistema miniaturizado de análise por injeção em fluxo visando a determinação de ferro nos digeridos com o reagente 1,10- fenantrolina e os resultados foram concordantes com o método de referência. / The texturized soy protein is a good source of protein and is usually used as an alternative to meat. The aim of this study was the evaluation of three wet decomposition procedures for multi-element analytical determination (Ca, K, Mg, P, Cr, Cu, Fe, Mn, Ni e Zn) in texturized soy protein samples using inductively coupled plasma optical emission spectrometry (ICP OES). In procedures using hot plate (PC) and heating block (PB), a mixture of HNO3 and H2O2 was used, whereas for decomposition in a focused-microwave-oven (PF), the use of H2SO4 was necessary. The analytical figures of merit of the developed analytical procedures such as precision, accuracy and matrix effect, were statistically assessed. The concentrations of Al, Cd, Co and Pb were found below oh the LOQ. The accuracy of the results was demonstrated using one certified reference material (spinach leaves NIST 1570a) and comparison with recommended AOAC official method. Moreover, a flow injection analysis microsystem for determination of iron with 1,10-phenantroline was optimized and the results were concordant with those obtained with the reference method.
58

Aplicação de técnicas quimiométricas na otimização de métodos usando a espectrometria de emissão óptica com plasma indutivamente acoplado e espectrometria de absorção atômica com chama visando a análise de amostras ambientais

Novaes, Cleber Galvão January 2011 (has links)
174f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-03T14:55:10Z No. of bitstreams: 1 Tese Cleber.pdf: 3023251 bytes, checksum: 3c19c67227656dc28f623ea371c6e7dd (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-23T15:23:58Z (GMT) No. of bitstreams: 1 Tese Cleber.pdf: 3023251 bytes, checksum: 3c19c67227656dc28f623ea371c6e7dd (MD5) / Made available in DSpace on 2013-04-23T15:23:58Z (GMT). No. of bitstreams: 1 Tese Cleber.pdf: 3023251 bytes, checksum: 3c19c67227656dc28f623ea371c6e7dd (MD5) Previous issue date: 2011 / CAPES / Nesta tese é apresentada a aplicação de técnicas quimiométricas na otimização de métodos usando a espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de absorção atômica com chama (F AAS) visando a análise de amostras ambientais. No primeiro trabalho, variáveis como potência de radiofrequência, vazão do gás do plasma, vazão do fluxo de nebulização, vazão do gás auxiliar, vazão da amostra e concentração de ácido nítrico na amostra foram otimizadas através da aplicação de planejamento fatorial completo e Box-Behnken. Parâmetros analíticos como precisão, robustez, sensibilidade e exatidão mostraram-se adequados para determinação de Al, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Si, Sn, Sr, Ti, Tl, V e Zn em amostras de água subterrânea, água de rio, efluente e solo usando ICP OES. A estratégia de medição e o tempo total de análise também foram otimizados. O novo método foi implantado na rotina do laboratório da CETREL e está proporcionando uma enorme redução no consumo do argônio, em torno de 35 %, gerando uma economia de aproximadamente 320 m3 de argônio anuais, além da redução nos custos associados a outros acessórios do ICP OES. No segundo trabalho, três variáveis de pré-concentração do chumbo (pH, concentração do tampão e vazão da amostra) foram otimizadas empregando planejamento fatorial completo 23. O método é baseado na sorção de Pb(II) em uma minicoluna recheada com uma resina de Amberlite XAD-4 funcionalizada com 4-(5´- bromo-2´-tiazolilazo)orcinol (Br-TAO). O método apresentou limite de quantificação de 1,7 μg L-1, faixa linear de 1,7-200 μg L-1 e fator de enriquecimento de 36, para 25,0 mL de amostra. A exatidão do método foi verificada pela determinação de chumbo em material de referência certificado de água doce NIST 1643d. O método foi aplicado na determinação de chumbo em amostras de água coletadas na cidade de Jequié-BA usando F AAS. Os teores de chumbo variaram de 4,1 a 5,7 μg L-1. As ferramentas quimiométricas utilizadas nos dois trabalhos foram muito eficazes na otimização de variáveis importantes e permitiu um estudo descritivo das variáveis e suas interações. Os dois métodos apresentaram parâmetros analíticos adequados para determinação de metais e metalóides em amostras ambientais / Salvador
59

Estimativa de valores de referência para Cd, Co, Cr, Cu, Ni, Pb,e Zn em solos do entorno da Baía do Iguape, Bahia, Brasil

Pinelli, Milena Santos January 2012 (has links)
94 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-08T14:08:02Z No. of bitstreams: 1 Dissertação_Milena Pinelli Versão CD.pdf: 8574876 bytes, checksum: f2c4d5fb3dab22669ba4ef48a90fa8a1 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-06-06T15:15:34Z (GMT) No. of bitstreams: 1 Dissertação_Milena Pinelli Versão CD.pdf: 8574876 bytes, checksum: f2c4d5fb3dab22669ba4ef48a90fa8a1 (MD5) / Made available in DSpace on 2013-06-06T15:15:34Z (GMT). No. of bitstreams: 1 Dissertação_Milena Pinelli Versão CD.pdf: 8574876 bytes, checksum: f2c4d5fb3dab22669ba4ef48a90fa8a1 (MD5) Previous issue date: 2012 / CAPES / Os metais têm origem natural como componentes das rochas e nesta situação não apresentam riscos aos seres vivos. Atualmente existem poucos estudos relacionados à obtenção de valores de referência para concentrações naturais de metais em solos do Brasil, o que dificulta a ação dos órgãos fiscalizadores e algumas instituições em monitorarem os ambientes que podem ter sido contaminados por indústrias ou outros tipos de empreendimentos. Este trabalho teve como objetivo propor valores de referência para concentração dos metais Cd, Co, Cr, Cu, Pb, Mn, Ni e Zn em solo do entorno na Baía do Iguape. As amostras foram digeridas em forno de micro-ondas com cavidade utilizando o procedimento da Agência de Proteção Ambiental, EPA 3051A e para as determinações dos analitos foi empregada a espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). As linhas de emissão selecionadas foram, em nm: Cd II 226,502; Co II 228,615 nm; Cr II 267,716; Cu Il 213,598; Mn II 257,610; Ni II 216,555; Pb II 220,353; e Zn I 213,857. A validação foi feita avaliando-se os limites de detecção (LOD) e de quantificação (LOQ), a faixa linear de trabalho, precisão, análise de material de referência certificado e testes de adição e recuperação. O procedimento validado foi aplicado na caracterização dos solos formados a partir de sedimentos da Formação Barreiras, Arenito e Folhelho, quanto às concentrações dos analitos Cd, Co, Cu, Cr, Mn, Ni, Pb e Zn no entorno da Baía de Iguape. As faixas de concentrações obtidas para as áreas estudadas foram, em mg kg-1: Barreiras encosta: Cd (0,57 - 1,7), Co (4,5 - 5,7), Cr (33 - 73), Cu (7,0 - 16), Mn (74 - 123), Ni (5,0 - 13), Pb (4,8 - 16) e Zn (12 - 30); Barreiras plana: Cd (0,20 - 0,67), Co (1,3 - 2,2), Cr (23 - 48), Cu (3,2 - 4,8), Mn (46 - 56), Ni (4,2 - 12), Pb (2,5 - 8,3) e Zn (12 - 24); Arenito 1 Cd (0,12 - 0,43), Co (0,30 - 0,90), Cr (4,9 - 14), Cu (1,7- 4,1), Mn (12 - 30), Ni (1,2 - 3,7), Pb (2,7 - 7,5) e Zn (1,8 - 8,6); Arenito 2 : Co (0,7- 2,0), Cr (5,6 - 19,8), Cu (1,7 - 3,1), Mn (10 - 28), Ni (1,9 - 4,0), Pb (1,7 - 4,4) e Zn (1,7 - 6,5); Arenito 3 Cd (0,10 - 0,23), Co (0,40 - 1,5), Cr (2,9 - 12), Cu (1,2 - 4,5), Mn (15 - 31), Ni (1,0 - 4,0), Pb (2,6 - 6,6) e Zn (2,1 - 7,3); Folhelho Cd (0,32 - 1,1), Co (0,92 - 1,7), Cr (37 - 63), Cu (3,6 - 7,2), Mn (27 - 39), Ni (4,4 - 9,3), Pb (3,2 - 11) e Zn (10 - 18). De um modo geral as concentrações obtidas variaram na seguinte ordem decrescente Barreiras> Folhelho> Arenito. Para propor valores de referência para solos com características similares aos analisados, foram selecionadas as áreas Barreira encosta e Arenito 3 e aplicou-se a correlação linear de Pearson e análise de componentes principais (PCA), para selecionar quais parâmetros (metais e atributos) contribuem de forma efetiva para a elaboração das equações do modelo estatístico. As concentrações das amostras foram estimadas de forma satisfatória com as equações elaboradas. Para os solos de Barreiras encosta apenas Co e Pb não apresentaram valores confiáveis de predição enquanto que para o Arenito 3, somente Ni não apresentou resultados confiáveis, devido ao seu baixo coeficiente de determinação. / Salvador
60

Desenvolvimento de um procedimento alternativo para determinação de elementos traço em arroz empregando digestão assistida por micro-ondas com ácido nítrico diluído

Tarantino, Taiana do Bomfim January 2012 (has links)
66 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-05T15:41:01Z No. of bitstreams: 1 Dissertação_definitiva_Taiana Tarantino.pdf: 1712573 bytes, checksum: 77c5b3c337efd24e474e48df29eef98a (MD5) / Rejected by Ana Hilda Fonseca(anahilda@ufba.br), reason: tirar tese e colocar dissertação on 2013-06-06T12:41:22Z (GMT) / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-06-06T12:43:14Z No. of bitstreams: 1 Dissertação_definitiva_Taiana Tarantino.pdf: 1712573 bytes, checksum: 77c5b3c337efd24e474e48df29eef98a (MD5) / Rejected by Ana Hilda Fonseca(anahilda@ufba.br), reason: trocar tese por dissertação on 2013-06-06T15:42:43Z (GMT) / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-06-06T15:44:50Z No. of bitstreams: 1 Dissertação_definitiva_Taiana Tarantino.pdf: 1712573 bytes, checksum: 77c5b3c337efd24e474e48df29eef98a (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-06-07T14:45:02Z (GMT) No. of bitstreams: 1 Dissertação_definitiva_Taiana Tarantino.pdf: 1712573 bytes, checksum: 77c5b3c337efd24e474e48df29eef98a (MD5) / Made available in DSpace on 2013-06-07T14:45:02Z (GMT). No. of bitstreams: 1 Dissertação_definitiva_Taiana Tarantino.pdf: 1712573 bytes, checksum: 77c5b3c337efd24e474e48df29eef98a (MD5) Previous issue date: 2012 / CAPES / O arroz (Oryza sativa) é um dos cereais mais produzidos e consumidos, sendo o alimento básico na dieta de mais da metade da população mundial. A digestão ácida assistida por radiação micro-ondas usando ácidos diluídos vem sendo bastante utilizada, principalmente, por reduzir a concentração ácida mantendo a eficiência da digestão, gerando menor volume de resíduo e diminuindo o fator de diluição antes da análise. A determinação dos teores de nutrientes é de grande relevância devido à capacidade nutricional do arroz, que pode conter espécies essenciais ou contaminantes a saúde humana. O objetivo deste trabalho foi propor um procedimento de digestão com HNO3 diluído empregando forno de micro-ondas com cavidade para determinação de macro, micro e elementos traço (As, Ca, Cd, Fe, K, Mg, Mn, Mo, P, Se, Zn) em amostras de arroz por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de massas com plasma indutivamente acoplado (ICP-MS). Foi realizado um planejamento fatorial 32 e Box-Behnken e as variáveis investigadas foram: volume de HNO3 destilado, temperatura e tempo, ambos no último patamar do programa de aquecimento. As condições otimizadas foram 2 mL de HNO3 e temperatura de 200 ºC durante o tempo de 20 minutos. O volume de H2O2 30%, a massa e a granulometria da amostra foram fixados em 1,0 mL, 250 mg e 500 m, respectivamente. A exatidão foi avaliada com o material de referência certificado NIST 1568a e do teste de recuperação para os analitos investigados, que variaram entre 80,1 e 102,1 % e 96,6 e 109,8 %, respectivamente. A precisão foi verificada pelo desvio padrão relativo, sendo sempre inferior a 10%, inclusive no teste de repetitividade. O procedimento proposto foi aplicado na determinação dos elementos em 23 amostras de arroz submetidas a três tipos de processamentos (polido, parboilizado e integral). As faixas de concentração para os elementos traço, em μg g-1, foram: Al (<2,4-15,3); As (<0,2-0,32); Cd (<0,004–0,017); Cu (0,2-2,2); Fe (<0,2- 17,4); Mn (2,8-34,9); Mo (<0,20-0,81); Se (<0,2-0,271) e Zn (4,8-14,9). De modo geral, os resultados obtidos encontram-se concordantes com as faixas de concentração descritas na literatura. / Salvador

Page generated in 0.0638 seconds