• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1209
  • 44
  • 40
  • 39
  • 34
  • 27
  • 16
  • 12
  • 8
  • 8
  • 7
  • 5
  • 3
  • 1
  • 1
  • Tagged with
  • 1250
  • 648
  • 110
  • 102
  • 101
  • 101
  • 100
  • 92
  • 91
  • 86
  • 85
  • 76
  • 73
  • 73
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
451

Análise de parâmetros cinéticos em mulheres com Síndrome da Dor Femoropatelar no gesto de subida de escada /

Silva, Danilo de Oliveira. January 2015 (has links)
Orientador: Fábio Mícolis de Azevedo / Coorientador: Fernando Amâncio Aragão / Banca: Rafael Zambelli de Almeida Pinto / Banca: Fernando Henrique Magalhães / Resumo: A Síndrome da Dor Femoropatelar é exacerbada durante atividades funcionais, como subir degraus. Apesar de sua etiologia permanecer indefinida, sabe-se que ocorrem problemas no alinhamento do membro inferior acometido, decorrente de alterações locais, distais e proximais a patela. O estudo das forças de reação do solo e deslocamento do centro de pressão durante a subida de escadas é pouco utilizado para análise da Síndrome da Dor Femoropatelar, entretanto, identificar e entender se existe e como se dão essas alterações é extremamente importante para o entendimento desta disfunção. Neste contexto, este projeto tem como objetivo geral investigar os padrões dinâmicos cinéticos em mulheres com Síndrome da Dor Femoropatelar, durante subida de escadas. Foram recrutadas 62 mulheres para participarem do estudo, 31 com Síndrome da Dor Femoropatelar e 31 assintomáticas. As participantes subiram 5 vezes uma escada instrumentada de 7 degraus, com uma plataforma de força embutida no quarto degrau. Foram extraídos parâmetros referentes ao centro de pressão e da força vertical de reação solo... / Abstract: Patellofemoral Pain Syndrome often affects athletes and sedentary population, causing anterior knee pain that is exacerbated during functional activities such as climbing stairs. Despite its etiology remains inconclusive, it is known that problems occur in the affected lower limb alignment, resulting from changes in local, distal and proximal to the knee. The study of ground reaction and center of pressure displacement during stair climbing is hardly used for Patellofemoral Pain Syndrome analysis, however, identify and understand if there is and how these changes occur is extremely important for Patellofemoral Pain Syndrome understanding. In this context, the aim of this project was investigating kinetic dynamic patterns in women with Patellofemoral Pain Syndrome during stair climbing. 62 women were recruited to participate in the study, 31 with Patellofemoral Pain Syndrome and 31 pain free. The participants performed 5 stair ascents under an instrumented 7 steps stairs with an embedded force platform on the fourth step. Parameters related to the center of pressure and the vertical ground reaction force were extracted... / Mestre
452

Comportamento mecânico de sistemas prótese/implante em região dos elementos finitos e interferometria holográfica /

Corrêa, Cássia Bellotto. January 2013 (has links)
Orientador: Luís Geraldo Vaz / Coorientador: Rogério Margomar / Coorientador: Pedro Yoshito Noritomi / Banca: Carlos Alberto dos Santos Cruz / Banca: Valfrido Antonio Pereira Filho / Banca: Mário Augusto Pires Vaz / Banca: Rodrigo Alvarenga Rezende / Resumo: A proposta deste estudo foi analisar, por meio do método de elementos finitos (MEF), o comportamento mecânico das estruturas envolvidas em uma reabilitação implanto suportada de 4 elementos na região anterior de maxila, utilizando apenas 2 implantes, variando os posicionamentos dos implantes e o tipo de conexão protética (hexágono externo, hexágono interno e cone-Morse) e ainda validar metodologia de análise computacional por meio da interferometria holográfica, uma técnica experimental. Modelos tridimensionais baseados em um banco de tomografias computadorizadas foram criados para todas as situações estudadas (Implantes nos Incisivos Laterais - IL; Implantes nos Incisivos Centrais - IC e Implante no Incisivo Central e Incisivo Lateral - ILIC). Uma carga equivalente à 150N foi aplicada a 45° na região de cíngulo de cada elemento dentário. Para a validação da metodologia de elementos finitos por meio da interferometria holográfica, criou-se um modelo prototipado com as mesmas situações estudadas e comparou-se os deslocamentos direcionais resultantes da aplicação de 3 intensidades de força. Como resultado foi observado: o menor deslocamento da estrutura protética e maior deslocamento na estrutura óssea no grupo IC. No tecido ósseo, a tensão de von Misses localiza-se predominantemente na região cortical. O valor máximo de tensão de von Misses foi observado no implante vizinho ao cantilever no grupo ILIC. Na conexão cone Morse, o parafuso protético mostrou metade da tensão de von Misses em relação a conexão hexágono interno e hexágono externo. Comparando-se os deslocamentos direcionais nas duas metodologias, verificou-se que havia uma correlação positiva entre os resultados, porém os valores obtidos experimentalmente eram superiores aos do modelo computacional. Pode-se concluir... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to analyze, by finite element method (FEM), the mechanical behavior of structures involved in an implant supported rehabilitation of 4 elements in the anterior maxilla, using only 2 implants, varying the placements of the implants and prosthetic connection types (external hexagon, internal hexagon and Morse taper) Moreover to validate the methodology of MEF by holographic interferometry, an experimental technique. Three-dimensional models based on a database CT scans were created for all situations studied (Implants in Lateral Incisors - IL; Implants in Central Incisors IC and Implant in Central e Lateral Incisor - ILIC). An equivalent load of150N was applied at 45° in the cingulum of each tooth. To validate the finite element method by Holographic Interferometry, a prototyped model was created with the same situations studied and compared the directional displacements, resulting from the application of the 3 intensities of force. As results it was observed: the lowest prosthetic displacement structure and greater displacement in the bone structure in the IC group. In bone tissue, the von Mises stress is located predominantly in the cortical region. The maximum value of von Mises stress was observed in the implant neighboring to cantilever in the group ILIC. In Morse taper connection, the prosthetic screw showed half the von Misses stress in relation to internal and external hexagon connection. Comparing the directional displacement in both methodologies, an positive correlation between the results was found, although the experimentally values obtained were higher than those of the computational model. It can be concluded that the placement of implants and prosthetic connection type have influence in the intensity and distribution of stress/strain on the implant-supported rehabilitation of anterior... (Complete abstract click electronic access below) / Doutor
453

Desenvolvimento de um sistema de medição das forças de reação com o solo

Fraga, Carlos Eduardo Nadal January 2013 (has links)
Made available in DSpace on 2014-06-25T02:02:25Z (GMT). No. of bitstreams: 1 000458791-Texto+Completo-0.pdf: 3669979 bytes, checksum: ae987aef3866993412581decd95a00df (MD5) Previous issue date: 2013 / The development of a measurement system for the measurement of ground reaction forces can provide important information about human physical performance and the health of the locomotor system, as well as the magnitude and form of application of these forces on different surfaces. However, the majority of commercially available force plates have major limitations in respect of their lack of portability and ability to send data for interpretation and analysis using wireless technology. The purpose of this work is to develop a Measurement System with Reaction Forces Ground (SMFRS) portable that uses wireless communication allowing data transmission in real time. The methodology of work includes a development phase and a test phase components.The developed platform combined structure rigidity and low weight, being composed of the following systems: signal conditioner, for amplification and filtering of signals; data acquisition device USB6009, for analog-to-digital conversion of the signals collected by the data acquisition card; communication module operated through Bluetooth connection. Preliminary testing demonstrated adequate connectivity of the force plate. Further testing is required to assess its sensitivity and accuracy. It is believed that this system is capable of the remote measurement of ground reaction forces, whilst still retaining portability. This system has potential for application in the areas of aerospace, clinical and sports biomechanics, allowing, for example, the evaluation of ground reaction forces during human gait studies in simulated hypogravity. / O desenvolvimento de um sistema de medição das forças verticais de reação com o solo pode trazer informações importantes sobre o desempenho físico humano, a saúde do aparelho locomotor, bem como a magnitude e a forma de aplicação dessas forças em diferentes superfícies. Há, porém, uma grande limitação da maioria das plataformas de força comercialmente disponíveis no que diz respeito à sua portabilidade e ao envio de dados por tecnologia sem fio para interpretação e análise. A proposta deste trabalho é desenvolver um Sistema de Medição das Forças de Reação com o Solo (SMFRS) portátil que utilize comunicação sem fio permitindo o envio dos dados em tempo real. A metodologia do trabalho compreende uma fase de desenvolvimento e uma fase de teste dos componentes.A plataforma desenvolvida combina rigidez da estrutura e baixo peso, sendo composta pelos seguintes sistemas: condicionador de sinais, para amplificação e filtragem dos sinais; dispositivo de aquisição de dados USB6009, para conversão analógico-digital dos sinais coletados pela placa de aquisição; e módulo de comunicação por meio de conexão Bluetooth. Os testes preliminares mostraram que a Plataforma apresenta conectividade adequada, sendo que testes posteriores avaliarão sua sensibilidade e precisão. Acredita-se que esse sistema é capaz de medir as forças de reação com o solo de forma remota, permitindo ainda sua portabilidade. As aplicações desse sistema envolvem as áreas da biomecânica esportiva, clínica e aeroespacial, possibilitando, por exemplo, a avaliação das forças de reação com o solo durante estudos da marcha humana em simulações de hipogravidade.
454

Desenvolvimento de um estabilômetro para estudo do equilíbrio humano

Barros, Marcos Braga January 2008 (has links)
Made available in DSpace on 2013-08-07T18:52:55Z (GMT). No. of bitstreams: 1 000406566-Texto+Completo-0.pdf: 3690637 bytes, checksum: 1b053f63fbbfd86428f3ac323799607a (MD5) Previous issue date: 2008 / Stabilometry is defined as a biomechanical method that aims to quantify human balance by means of the measurement of a subject’s centre of pressure (COP). Dynamic platforms cause mechanical stimulation on a subject’s feet and are used to evaluate the balance human dynamic balance. This type of biomechanical tool, however, is not easily found in the Brazilian commercial market. Therefore, this study aimed to develop a Stabilometer based on a tri-axial accelerometer, according to Nasher’s platform. The results showed that the developed Stabilometer prototype has become more mechanically and electrically stable than the earlier developed prototypes (prototypes 1 &2). The developed prototype, based on a careful study of human physiology has shown itself to be quite stable and meets the proposed goals. It should be noted that the developed Stabilometer when built is easy to install and inexpensive when compared with commercial equipment. With this Stabilometer it is routinely possible to measure the balance of individuals requiring such assistance in the treatment and prevention of diseases that compromise the visual and sensory systems. / Define-se Estabilometria como um método biomecânico que visa quantificar o equilíbrio humano por meio da medição do centro de pressão (COP) dos pés de uma pessoa. As plataformas dinâmicas provocam a estimulação mecânica dos pés de um indivíduo e são usadas para avaliar o equilíbrio em indivíduos humanos. Este tipo de ferramenta biomecânica, porém, não é facilmente encontrada no mercado comercial brasileiro. Assim, este estudo teve como objetivo desenvolver um Estabilômetro baseado em um acelerômetro tri axial, de acordo com a plataforma de Nashner. Os resultados mostraram que o protótipo desenvolvido do Estabilômetro tornou-se mais estável mecanicamente e eletricamente que protótipos construídos anteriormente (protótipos 1 e 2). O protótipo desenvolvido foi baseado em um estudo criterioso da fisiologia humana mostra-se bastante estável e atende aos objetivos propostos. Cabe ressaltar, que o Estabilômetro construído é de fácil instalação e baixo custo, quando comparado com os equipamentos comerciais. Com este Estabilômetro é possível medir rotineiramente o equilíbrio de indivíduos, que necessitem deste auxílio no tratamento e na prevenção de doenças, que comprometem os sistemas visual, vestibular e somatosensorial.
455

Desenvolvimento e estudo in vitro de implante biorreabsorvível em poli (L-lactídeo) (PLLA) para artrodese de coluna lombar

Simões, Marcelo Simoni January 2007 (has links)
Made available in DSpace on 2013-08-07T18:55:07Z (GMT). No. of bitstreams: 1 000392095-Texto+Completo-0.pdf: 8066982 bytes, checksum: 885e520a0346e48e1e77c1dd4610477e (MD5) Previous issue date: 2007 / The current implants for spinal interbody fusion protect the graft against mechanical loading, potentially inducing a weak bone consolidation. The ideal behavior for those implants would be to keep its resistance until the occurrence of bone consolidation and, then, to be eliminated, leaving mechanical stresses over the new created bone. Poly(L-lactic acid) (PLLA) is a biocompatible and bioresorbable aliphatic polyester, already used as a material for orthopedic implants. With the objectives of obtaining data on the behavior of this polymer and developing a methodology to help in choosing materials for new studies, aiming at a future clinical application, the design and production of a lumbar interbody fusion implant in PLLA, followed by evaluation of its’ in vitro degradation for one year, was proceeded. The implant was developed with a computer assisted design (CAD) program, tested virtualy by finite element analisis (FEA) and produced by injection in industrial hardware. Studies of gel permeation chromatography (GPC), differential scanning calorimetry (DSC), mechanical compression and scanning electron microscopy (SEM), are performed on the non degraded implants and at tree months intevals of degradation. Mass loss of implants in degradation was also controlled. The implant showed excellent resistance and ductility during all time of the experiment, tolerating compression forces over 10000N. However, the amount of degradation in the period of observation was very low, with very slight changes in the implants’ mass and size of polymer chains, as detected by mass loss and GPC studies. Although the low degradation proved that PLLA is not adequate for this application, the goals of validating the methodology used and obtaining data on a preliminary model, for use in a second phase of research, were achieved. / Os implantes para artrodese intersomática da coluna utilizados atualmente protegem o enxerto do carregamento mecânico, podendo induzir uma consolidação óssea falha. O comportamento ideal desses implantes seria manter a resistência até a consolidação óssea e, após, ser eliminados, deixando que o tecido ósseo assuma as cargas. O poli(L-ácido lático) (PLLA) é um poliéster alifático biocompatível e biorreabsorvível, já utilizado como matéria-prima em implantes ortopédicos. Com os objetivos de obter dados sobre o comportamento deste polímero, bem como de desenvolver uma metodologia que possa auxiliar na escolha de matérias-primas para novos estudos, visando uma futura aplicação clínica, foram realizados o projeto e produção de um implante para artrodese intersomática lombar em PLLA, juntamente com a avaliação do seu comportamento de degradação in vitro pelo período de um ano. O implante foi desenvolvido em um programa de projeto assistido por computador (CAD), ensaiado computacionalmente por análise de elementos finitos (FEA) e produzido por injeção em maquinário industrial. Ensaios de cromatografia de permeação em gel (GPC), calorimetria exploratória diferencial (DSC), compressão mecânica e microscopia eletrônica de varredura (MEV) foram realizados nos implantes não degradados e a cada três meses de degradação. A perda de massa dos implantes em degradação também foi acompanhada.O implante apresentou resistência e ductlidade excelentes durante todo o período testado, suportando compressões acima de 10000N. A degradação no período observado foi, entretanto, muito baixa, havendo pouquíssima alteração na massa do implante e no tamanho das cadeias do polímero, conforme avaliado por ensaios de perda de massa e GPC. Embora a baixa degradação tenha provado que o PLLA não é o polímero mais adequado para a aplicação pretendida, o trabalho alcançou seus objetivos de validar a metodologia utilizada e testar um modelo inicial, obtendo os parâmetros para utilização em uma nova fase da pesquisa.
456

A importância da análise do apoio plantar em idosos: um estudo comparativo entre jovens e idosos

Chiappin, Daniela January 2007 (has links)
Made available in DSpace on 2013-08-07T18:56:29Z (GMT). No. of bitstreams: 1 000404133-Texto+Completo-0.pdf: 716570 bytes, checksum: 135b0491a12db941f5ad3e845f6494f0 (MD5) Previous issue date: 2007 / The measurement of the distribution of the plantar pressure is a method which has been used nowadays to evaluate possible feet pathologies. With aging physiologic changes take place, including the march, which has a relation to the distribution of plantar pressure. This study aimed to measure and also compares the distribution of the plantar pressure in groups of young adults and aged adults. The sample counted on 29 young participants (30,4 ± 5,0) and 29 old participants (68,1 ± 6,4), healthy, without any pathology on lower limbs and feet. The distribution of the plant pressure was carried out while walking, in a dynamic way, accomplished through the method with capacitive insoles (pedar novelgmbh ,2005) inserted in a standardized shoe for both genres, with the objective of analyzing the pressure peak and through the system of pressure plafform (emed-x novelgmbh ,2004) barefoot to evaluate the variable of the maximum peak of pressure, contact area and center of pressure. The foot was divided in three faces: rearfoot, forefoot and middlefoot. The result found was a smaller pressure on the total peak of the foot in the group of old ones who were wearing shoes. There was no difference regarding the group who was barefoot. The contact area was bigger in the group of old ones in the rearfoot region and the trajectory line of the center of pressure was similar for both of the groups. The conclusion of the present study shows that the hypothesis of the existence of significant differences between the distribution of the plantar pressure in the groups was correct, this happens with ageing, occurring a smaller plantar pressure during the walking, and it can show a more conservative march, with a bigger support in the first moment of the touching of the heel. This leads us to recommend that more studies can be carried out taking into consideration different ages, genres and bigger samples. / A mensuração da distribuição da pressão plantar é um método que atualmente tem sido utilizado para avaliar possíveis patologias dos pés. Com o avançar da idade, modificações fisiológicas vão acontecendo, inclusive na marcha, que possui relação com a distribuição da pressão plantar. Este estudo teve a finalidade de mensurar e comparar a distribuição da pressão plantar em grupos de adultos jovens e de adultos idosos. A amostra foram 29 participantes jovens (30,4 ± 5,0), e 29 participantes idosos (68,1 ± 6,4) saudáveis, sem patologias de membros inferiores e pés. A distribuição da pressão plantar foi realizada ao caminhar, de forma dinâmica, realizada através do método com palmilhas capacitivas (pedar novelgmbh, 2005) introduzidas em um calçado padronizado para ambos os gêneros, com objetivo de analisar o pico de pressão e através do sistema de plataforma de pressão (emedx novelgmbh, 2004) com os pés descalços, para avaliar as variáveis pico de pressão máxima, área de contato e centro de pressão. O pé foi dividido e três mascaras: retropé, mediopé e antepé. Os resultados encontrados foi uma pressão menor no pico total do pé no grupo dos idosos com os pés calçados. Não houve diferença com o grupo com os pés descalços. A área de contato foi maior nos idosos na região do retropé e a linha da trajetória do centro de pressão foi semelhante para ambos os grupos. A conclusão do presente estudo mostra que a hipótese de que existem diferenças significativas entre a distribuição da pressão plantar nos grupos foi acertada, isto acontece com o avançar da idade, ocorrendo menor pressão plantar durante a caminhada, podendo apresentar uma marcha mais conservadora, com maior apoio no primeiro momento do toque do calcanhar. Isto nos leva a recomendar que sejam realizados mais estudos, levando em conta diferentes idades, por gênero, amostras maiores.
457

Análise eletromiográfica e dinamométrica do tronco de jovens com e sem dor lombar crônica inespecífica

Rossi, Denise Martineli [UNESP] 24 April 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-04-24Bitstream added on 2014-06-13T19:48:17Z : No. of bitstreams: 1 rossi_dm_me_rcla_parcial.pdf: 112569 bytes, checksum: 6a054f5b73756d21441d9424a524700f (MD5) Bitstreams deleted on 2015-02-04T11:39:26Z: rossi_dm_me_rcla_parcial.pdf,Bitstream added on 2015-02-04T11:40:12Z : No. of bitstreams: 1 000713946.pdf: 439282 bytes, checksum: af0e9b43a3b1f178bf2e4d9d7792e7c3 (MD5) / A dor lombar crônica inespecífica é um sintoma musculoesquelético de grande incidência que leva a prejuízos na funcionalidade e na qualidade de vida, além de acarretar gastos significativos ao sistema de saúde. Esse sintoma apresenta etiologia multifatorial e está relacionado a variáveis neuromusculares, proprioceptivas e capacidades físicas como força e resistência muscular. Com isso, o objetivo deste estudo foi avaliar variáveis biomecânicas e verificar o poder de discriminação destas, entre jovens com dor lombar crônica inespecífica e assintomáticas. Participaram do estudo 28 indivíduos do gênero feminino, na faixa etária entre 18 e 30 anos, na qual foram divididas em dois grupos, conforme o relato de dor lombar nos seis meses prévios ao estudo, sendo um grupo com dor lombar (GDL, n=14) e um grupo controle (GC, n=14). No primeiro dia, as voluntárias foram submetidas a avaliação da intensidade da dor por meio da Escala Visual Analógica (EVA), avaliação proprioceptiva do tronco no Dinamômetro Isocinético por meio do teste de reposicionamento passivo do tronco, antes e após a avaliação de resistência muscular (Teste de Biering-Sorensen), a fim de investigar o efeito da fadiga na propriocepção do tronco. Neste mesmo dia, as voluntárias realizaram familiarização e avaliação isométrica do tronco. No segundo dia, foi repetido o protocolo de avaliação isométrica e simultaneamente a essa avaliação, foi coletado o sinal eletromiográfico dos músculos locais obliquo interno (OI) e multifidos (MU) e músculos globais, reto abdominal (RA) e longuíssimo do tórax (LT), bilateralmente. Neste estudo, também foram avaliadas as variáveis Taxa de Desenvolvimento de Força (TDF) e a Taxa de Aumento Eletromiográfico (TAE) partir de diferentes modos de processamento do sinal dinamométrico e eletromiográfico... / Nonspecific chronic low back pain is a musculoskeletal symptom of high incidence leading to losses in functionality and quality of life, and result in significant costs to the health system. This symptom has a multifactorial etiology and is related to neuromuscular and proprioceptive variables and physical abilities such as strength and muscular endurance. Thus, the aim of this study was to analyze the biomechanical variables between asymptomatic young and young with nonspecific chronic low back pain. The study included 28 healthy females, aged between 18 and 30 years, which were separated into two groups according to the report of back pain in the six months prior to the study, one group with low back pain (LBP, n = 14) and a control group (CG, n = 14). On the first day, the volunteers underwent trunk proprioceptive assessment in Isokinetic Dynamometer before and after a muscular endurance test in order to investigate the effect of fatigue on trunk proprioception. That same day, the volunteers performed familiarization and trunk isometric assessment. On the second day, was repeated the isometric evaluation and was simultaneously collected electromyographic signal of the local muscles, internal oblique (IO) and multifidus (MU) and global muscles, rectus abdominus (RA) and longissimus thoracis (LT), bilaterally. In this study, we evaluated the variables Rate of Force Development (RFD) and Rate Increase Electromyographic (RIE) from different processing modes dynamometric and electromyographic signal. The LBP had higher pain intensity compared to CG before testing resistance, but after the test, the groups did not were accepted each other. In addition, young people with low back pain had lower values of peak extensor torque (23%), peak extensor and flexor torque normalized by body mass, 30% and 19% respectively, compared... (Complete abstract click electronic access below)
458

Propriocepção e respostas musculares do tornozelo de atletas universitários de futebol

Almeida Neto, Antônio Francisco de [UNESP] 29 April 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-04-29Bitstream added on 2014-06-13T19:39:18Z : No. of bitstreams: 1 almeidaneto_af_me_rcla.pdf: 421955 bytes, checksum: 5a69474a1c0c60de8fd450eb23dd626a (MD5) / Introdução: o futebol é o esporte mais praticado no mundo, e por isso muitas pessoas estão expostas a lesões comuns de sua prática, sendo a mais comum o entorse de tornozelo. Em casos de entorses recidivos pode-se desenvolver a instabilidade funcional de tornozelo. O objetivo deste estudo foi comparar as respostas musculares e a propriocepção de atletas universitários de futebol e futsal com e sem instabilidade de tornozelo. Métodos: foram avaliados 20 atletas divididos em dois grupos: estável (GE: n=10; idade 23,89 ± 2,85 anos; estatura 1,75 ± 0,05m; massa corporal 79,40 ± 8,35kg) e instável (GI: n=10; idade 21,70 ± 2,71 anos; estatura 1,74 ± 0,04m; massa corporal 71,88 ± 6,94kg). Os atletas foram avaliados em dois dias. No primeiro dia foram realizados os testes de equilíbrio em apoio unipodal sobre uma plataforma de força e o de reposicionamento articular passivo do tornozelo em um dinamômetro isocinético. O teste de equilíbrio foi realizado com olhos abertos e fechados, foram feitas três tentativas para cada condição com duração de 20 segundos. A frequência de amostragem da plataforma de força foi ajustada em 2000 Hz. O teste de reposicionamento articular passivo foi realizado com ângulos alvo de 10º e 20º. No segundo dia foi realizado o teste de simulação de entorse enquanto eram coletados dados eletromiográficos e cinemáticos. No teste de simulação de entorse os atletas caminhavam sobre uma plataforma onde havia dispositivos para simular o movimento do entorse de tornozelo. O sinal eletromiográfico foi coletado nos músculos tibial anterior (TA), fibular longo (FL) e fibular curto (FC), com frequência de amostragem de 2000 Hz, filtro passa-banda de 20-500 Hz, ganho de 2000 vezes (20 vezes no pré-amplificador e 100 no conversor). A cinemática foi coletada a 250 quadros por segundo, com marcadores... / Introduction: soccer is the most practiced sport in the world, and several people are exposed to the common injuries of this sport, and the ankle sprain is the most common injury. In case of several ankle sprains, the functional ankle instability may occur. The aim of the present study was to compare the muscular responses and the proprioception of college soccer and futsal athletes with and without ankle instability. Methods: were evaluated 20 athletes divided into two groups: stable (GE: n=10; age 23,89 ± 2,85 years; height 1,75 ± 0,05m; body mass 79,40 ± 8,35kg) and unstable (GI: n=10; age 21,70 ± 2,71 years; height 1,74 ± 0,04m; body mass 71,88 ± 6,94kg). The athletes were evaluated in two days. On the first were performed the single-leg balance test on a force plate and the passive ankle joint repositioning test on the isokinetic dynamometer. The balance test was performed with eyes opened and closed, were recorded three trials of 20 seconds for each condition. The sample rate was set to 2000 Hz. The passive joint repositioning test was performed with target angles of 10º and 20º. On the second day, the ankle sprain simulation test was performed while electromyographic and kinematic data were collected. The athletes had to walk on a platform with ankle sprain simulation devices. The electromyographic signal of the tibialis anterior (TA), the peroneus longus (FL) and peroneus brevis (FC), with sample rate of 2000 Hz, band-pass filter of 20-500 Hz, gain of 2000 times (20 times on the pre-amplificator and 100 on the conversor). The kinematic was collected with sample rate of 250 frames per second, with fotorrelfexive markers attached to the lower limbs. The data obtained was relative to center of pressure displacements, absolute angular error in 10º and 20º, muscular response time, muscular activation, electromyographic... (Complete abstract click electronic access below)
459

Lesão do tendão flexor: sutura na região avascular ou vascularizada? Estudo biomecânico e histopatológico em coelhos

Sardenberg, Trajano [UNESP] 09 June 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-06-09Bitstream added on 2014-06-13T19:00:27Z : No. of bitstreams: 1 sardenberg_j_dr_botfm.pdf: 1588012 bytes, checksum: 25f659fb0a5ae4d2f5ea55bb53dae425 (MD5) / Fundação para o Desenvolvimento Médico e Hospitalar (Famesp) / Há dúvidas em relação à melhor localização da sutura no reparo da lesão do tendão flexor dos dedos da mão, uma vez que o ponto central colocado na região dorsal vascularizada, apesar de gerar maior resistência que o ponto na região palmar, poderia, entretanto, interferir no suprimento sangüíneo do tendão. O objetivo da presente investigação foi avaliar, por meio da biomecânica e histopatologia, o efeito da sutura central na região de tendão normal vascularizada e na região de tendão fibrocartilaginoso avascular, no processo de cicatrização do tendão flexor profundo dos dedos do pé do coelho. Foram estudados 83 coelhos submetidos à sutura central tipo Kessler na região de tendão normal (grupo TN) e na região de tendão fibrocartilaginoso (grupo FC), completada com sutura periférica circunferêncial contínua. Após a cirurgia, o membro operado foi imobilizado pelo período de três semanas. Os animais foram sacrificados no período imediato, duas, três e seis semanas de pós-operatório. Concluiu-se que a colocação da sutura central na região de tendão normal vascularizada ou fibrocartilaginosa avascular não apresenta diferenças em relação aos aspectos biomecânicos e histopatológicos na cicatrização do tendão flexor profundo dos dedos do pé do coelho. / There are doubts concerning the best place for suture in repairing the lesion at flexor tendon of fingers. Although the core suture at vascular dorsal region generates more resistance than at palm region it may however interfere in tendon blood supply. The objective of the present research was to evaluate through biomechanics and histopathology the effect of core suture at vascular normal region of tendon as well as at avascular fibrocartilagenous tendon during healing of deep flexor tendon at rabbit toes. Eighty-tree animals were submitted to core Kessler suture at normal tendon region (NT group) as well as at fibrocartilagenous tendon region (FC group) completed with continuous circumferential periphery suture. After surgery the operated extremity was immobilized for a three weeks . The animals were sacrificed immediately and after two, three and six weeks of surgery. It was concluded that core suture at normal or fibrocartilagenous tendon region showed no differences concerning biomechanical and histopathological aspects in healing of deep flexor tendon of rabbit toes.
460

Desenvolvimento de uma plataforma de forças para medição e análise dos esforços verticais para modelamento biodinâmico da caminhada humana

Toso, Marcelo André January 2012 (has links)
O corpo humano pode interagir com as estruturas e estas interações são desenvolvidas através da aplicação de forças devido ao seu movimento. Uma estrutura pode sofrer alterações no seu comportamento dinâmico quando sujeita a cargas. Neste trabalho, o projeto e a construção de uma plataforma de forças é apresentado para medir as Forças de Reação do Solo (FRS) e aceleração para análise da marcha humana. A plataforma é constituída por duas placas colocadas lado a lado em relação à direção da caminhada, de modo que o sinal de força de cada pé pode ser adquirido separadamente em cada placa. A plataforma é projetada de forma a ser compatível com as frequências envolvidas nas medições. Cada placa tem três células de carga do tipo anel instrumentadas com strain gauges. A plataforma foi calibrada com um procedimento padrão e com uma nova metodologia utilizando redes neurais artificiais as incertezas dos parâmetros medidos (força e posicionamento x, y) foram avaliados. Um modelo de elementos finitos foi utilizado para avaliar as características dinâmicas da plataforma. Os resultados foram valores de frequência muito próximos aos medidos na análise experimental e confirmaram sua adequação ao uso, pois as frequências foram maiores do que as envolvidas na marcha humana. Características relevantes da FRS, como os picos de apoio de força, impulso e também a força de impacto, podem ser observadas a partir dos dados coletados. Os dados da FRS assim como os dados de aceleração medidos estavam condizentes com os valores apresentados na literatura. / The human body may interact with the structures and these interactions are developed through the application of forces due to its motion. A structure may undergo changes in their dynamic behavior when subjected to loads. In this work, the design of a force platform is presented to measure the Ground Reaction Force (GRF) and acceleration for human gait analysis. The platform consists of two plates placed side by side in relation to the direction of walking, so that the signal from each foot can be acquired in separate in each plate. The platform is designed in order to be compatible with the frequencies involved in the measurements. Each plate has three ring-type load cells instrumented with strain gauges. The platform was calibrated with a standard procedure and with a new methodology using artificial neural networks the uncertainties of the measured parameters (force and position x, y) were evaluated. A finite element model was used to evaluate the dynamic characteristics of the platform. The results were frequencies values very close to those measured in the experimental analysis and confirm its adequacy to the use, because the frequencies were higher than the frequencies involved in the human gait. Relevant characteristics of GRF like the peaks of support force, impulse and the impact force could be observed from the data collected. The data of GRF as well as the measured acceleration data were consistent with values presented in the literature.

Page generated in 0.0175 seconds