• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 367
  • 111
  • 70
  • 37
  • 34
  • 13
  • 10
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 856
  • 856
  • 145
  • 91
  • 89
  • 86
  • 84
  • 64
  • 63
  • 61
  • 60
  • 60
  • 60
  • 59
  • 58
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
841

Magnetic resonance imaging of resting cerebral oxygen metabolism : applications in Alzheimer’s disease

Lajoie, Isabelle 02 1900 (has links)
The BOLD contrast employed in functional MRI studies is an ambiguous signal composed of changes in blood flow, blood volume and oxidative metabolism. In situations where the vasculature and metabolism may have been affected, such as in aging and in certain diseases, the dissociation of the more physiologically-specific components from the BOLD signal becomes crucial. The latest generation of calibrated functional MRI methods allows the estimation of both resting blood flow and absolute oxygen metabolism. The work presented here is based on one such proof-of-concept approach, dubbed QUO2, whereby taking into account, within a generalized model, both arbitrary changes in blood flow and blood O2 content during a combination of hypercapnia and hyperoxia breathing manipulations, yields voxel-wise estimates of resting oxygen extraction fraction and oxidative metabolism. In the first part of this thesis, the QUO2 acquisition protocol and data analysis were revisited in order to enhance the temporal stability of individual blood flow and BOLD responses, consequently improving reliability of the model-derived estimates. Thereafter, an assessment of the within and between-subject variability of the optimized QUO2 measurements was performed on a group of healthy volunteers. In parallel, an analysis was performed of the sensitivity of the model to different sources of random and systematic errors, respectively due to errors in measurements and choice of assumed parameters values. Moreover, the various impacts of the oxygen concentration administered during the hyperoxia manipulation were evaluated through a simulation and experimentally, indicating that a mild hyperoxia was beneficial. Finally, the influence of Alzheimer’s disease in vascular and metabolic changes was explored for the first time by applying the QUO2 approach in a cohort of probable Alzheimer’s disease patients and age-matched control group. Voxel-wise and region-wise differences in resting blood flow, oxygen extraction fraction, oxidative metabolism, transverse relaxation rate constant R2* and R2* changes during hypercapnia were identified. A series of limitations along with recommended solutions was given with regards to the delayed transit time, the susceptibility artifacts and the challenge of performing a hypercapnia manipulation in cohorts of elderly and Alzheimer’s patients. / Le contraste BOLD employé dans les études d’imagerie par résonance magnétique fonctionnelle (IRMf) provient d’une combinaison ambigüe de changements du flux sanguin cérébral, du volume sanguin ainsi que du métabolisme oxydatif. Dans un contexte où les fonctions vasculaires ou métaboliques du cerveau ont pu être affectées, tel qu’avec l’âge ou certaines maladies, il est crucial d’effectuer une décomposition du signal BOLD en composantes physiologiquement plus spécifiques. La dernière génération de méthodes d’IRMf calibrée permet d’estimer à la fois le flux sanguin cérébral et le métabolisme oxydatif au repos. Le présent travail est basé sur une telle technique, appelée QUantitative O2 (QUO2), qui, via un model généralisé, prend en considération les changements du flux sanguin ainsi que ceux en concentrations sanguine d’O2 durant des périodes d’hypercapnie et d’hyperoxie, afin d’estimer, à chaque voxel, la fraction d’extraction d’oxygène et le métabolisme oxydatif au repos. Dans la première partie de cette thèse, le protocole d’acquisition ainsi que la stratégie d’analyse de l’approche QUO2 ont été revus afin d’améliorer la stabilité temporelle des réponses BOLD et du flux sanguin, conséquemment, afin d’accroître la fiabilité des paramètres estimés. Par la suite, une évaluation de la variabilité intra- et inter-sujet des différentes mesures QUO2 a été effectuée auprès d’un groupe de participants sains. En parallèle, une analyse de la sensibilité du model à différentes sources d’erreurs aléatoires (issues des mesures acquises) et systématiques (dues aux assomptions du model) a été réalisée. De plus, les impacts du niveau d’oxygène administré durant les périodes d’hyperoxie ont été évalués via une simulation puis expérimentalement, indiquant qu’une hyperoxie moyenne était bénéfique. Finalement, l’influence de la maladie d’Alzheimer sur les changements vasculaires et métaboliques a été explorée pour la première fois en appliquant le protocole QUO2 à une cohorte de patients Alzheimer et à un groupe témoin du même âge. Des différences en terme de flux sanguin, fraction d’oxygène extraite, métabolisme oxydatif, et taux de relaxation transverse R2* au repos comme en réponse à l’hypercapnie, ont été identifiées au niveau du voxel, ainsi qu’au niveau de régions cérébrales vulnérables à la maladie d’Alzheimer. Une liste de limitations accompagnées de recommandations a été dressée en ce qui a trait au temps de transit différé, aux artéfacts de susceptibilité magnétique, de même qu’au défi que représente l’hypercapnie chez les personnes âgées ou atteintes de la maladie d’Alzheimer.
842

Étude de l’écoulement sanguin dans un anévrysme intracrânien avant et après traitement par stent flow diverter : quantification par traitement d’images de séquences angiographiques 2D / Blood flow study in an intracranial aneurysm before and after flow diverter treatment : quantification based on 2D digital angiography imaging processing

Bresson, Damien 14 November 2016 (has links)
Les anévrysmes intracrâniens (AIC) sont des malformations artérielles développées au dépend des vaisseaux qui vascularisent le parenchyme cérébral. Leur rupture provoque une hémorragie intracrânienne, appelée hémorragie sous-arachnoïdienne, responsable d'une mortalité importante ou de séquelles fonctionnelles lourdes. Le traitement préventif de ces lésions est fréquemment réalisé lors d'une procédure endovasculaire (appelée coiling), par implantation, au sein de la poche artérielle pathologique, de spires métallique en platine à détachement contrôlé (les coils). La présence de ce matériel provoque une thrombose de la poche ce qui entraine secondairement une exclusion de l'anévrysme de la circulation artérielle. Une modalité de traitement endovasculaire plus récente fait appel à un dispositif implantable innovant appelé stent "flow diverter" (FD) que l'on déploie en regard de l'orifice qui fait communiquer l'artère et l’anévrysme : le collet anévrysmal. Ces stents FD, au design particulier, associant une faible porosité à une densité de pores élevée, agissent comme des "déflecteurs" et diminuent le flux sanguin entrant et sortant de l'anévrysme. L'objectif du traitement demeure toujours l'exclusion de l'anévrysme mais celle-ci est obtenue indirectement en agissant sur la "porte d'entrée" de l'anévrysme (le collet) et non plus directement sur la poche anévrysmale elle-même. Il ne s'agit plus alors de remplir le sac anévrysmal avec des coils mais de provoquer une thrombose stable et pérenne en altérant uniquement le flux sanguin qui le pénètre. Cette modalité thérapeutique novatrice a suscité un engouement important de la part des neuroradiologues interventionnels depuis 2007, date des premières implantations en Europe. Cependant, bien que reposant sur les capacités d'un tel dispositif à modifier le flux, on constate qu'il existe très peu d'outils d'imagerie disponibles actuellement et capables de quantifier ces modifications en un délai raisonnable pour pouvoir être exploité lors du traitement endovasculaire. De cette constatation clinique est né un projet collaboratif dont la finalité était le développement d'un outil logiciel basé sur les séquences d'angiographie numérisées soustraites et capable de mesurer au moins un des aspects du flux sanguin (et donc de ses modifications). La démarche de recherche mise en œuvre s'est effectuée en trois étapes. Premièrement, une étape expérimentale portant sur la réalisation d'un modèle "optimisé" d'AIC permettant le recueil de données hémodynamiques et d'imagerie. Puis, une étape de recherche plus fondamentale comprenant deux parties: d'une part des simulations numériques réalisées dans le cadre d'un modèle 3D réaliste d'AIC et d'autre part l'analyse d'images angiographiques. Au cours de cette étape, nous avons utilisé des outils de traitement d'images existants et développé certains algorithmes, puis les avons validés avant de les implémenter sous JAVA pour créer un outil logiciel d'analyse de flux. Enfin, la dernière étape du projet a consisté en l'exploitation du logiciel pour étudier une série clinique de patients traités d'un AIC par stent FD. Elle a permis de mettre en évidence certains facteurs prédictifs d'exclusion de l'anévrysme à long terme susceptible d'avoir un impact, en temps réel, sur le traitement des AIC par stent FD. / Intracranial aneurysms treatment based on intra aneurismal flow modification tend to replace traditionally coiling in many cases and not only complex aneurysms for which they were initially designed. Dedicated stents (low porosity, high pores density stents) called “flow diverter” stents are deployed across the neck of the aneurysm to achieve this purpose. The summation of three different mechanisms tend to lead to the healing of the aneurysm: immediate flow alteration due to the mechanical screen effect of the stent, physiological triggering of acute or progressive thrombus formation inside the aneurysm’s pouch and long term biological response leading in neointima formation and arterial wall remodeling. This underlying sequence of processes is also supposed to decrease the recanalization rate. Scientific data supporting the flow alteration theory are numerous and especially computational flow dynamics (CFD). These approaches are very helpful for improving biomechanical knowledge of the relations between blood flow and pathology, but they do not fit in real-time treatments. Neuroendovascular treatments are performed under dynamic x-ray modality (digital subtracted angiography a DSA-).However, in daily practice, FD stents are sized to the patient’s 3D vasculature anatomy and then deployed. The flow modification is then evaluated by the clinician in an intuitive manner: the decision to deploy or not another stent is based solely on a visual estimation. The lack of tools available in the angioroom for quantifying in real time the blood flow hemodynamics should be pointed out. It would make sense to take advantage of functional data contained in contrast bolus propagation and not only anatomical data. Thus, we proposed to create flow software based on angiographic analysis. This software was built using algorithms developed and validated on 2D-DSA sequences obtained in a swine intracranial aneurysm model. This intracranial animal model was also optimized to obtain 3D vascular imaging and experimental hemodynamic data that could be used to realize realistic computational flow dynamic. In a third step, the software tool was used to analyze flow modification from angiographic sequences acquired during unruptured IA from patients treated with a FD stent. Finally, correlation between flow change and aneurysm occlusion at long term follow-up with the objective of identifying predictive markers of long term occlusion was performed.
843

Quantification de la perfusion myocardique en imagerie de perfusion par résonance magnétique : modèles et classification non-supervisée / Myocardial perfusion quatification by magnetic resonance imaging : models and unsupervised classification

Daviller, Clément 18 October 2019 (has links)
Les maladies cardiovasculaires et en particulier les maladies coronariennes représentent la principale cause de mortalité mondiale avec 17,9 millions de décès en 2012. L’IRM cardiaque est un outil particulièrement intéressant pour la compréhension et l’évaluation des cardiopathies, notamment ischémiques. Son apport diagnostique est souvent majeur et elle apporte des informations non accessibles par d’autres modalités d’imagerie. Les travaux menés pendant cette thèse portent plus particulièrement sur l’examen dit de perfusion myocardique qui consiste à étudier la distribution d’un agent de contraste au sein du muscle cardiaque lors de son premier passage. En pratique clinique cet examen est souvent limité à la seule analyse visuelle du clinicien qui recherche un hyposignal lui permettant d’identifier l’artère coupable et d’en déduire le territoire impacté. Cependant, cette technique est relative et ne permet pas de quantifier le flux sanguin myocardique. Au cours de ces dernières années, un nombre croissant de techniques sont apparues pour permettre cette quantification et ce à toutes les étapes de traitement, depuis l’acquisition jusqu’à la mesure elle-même. Nous avons dans un premier temps établi un pipeline de traitement afin de combiner ces approches et de les évaluer à l’aide d’un fantôme numérique et à partir de données cliniques. Nous avons pu démontrer que l’approche Bayésienne permettait de quantifier la perfusion cardiaque et sa supériorité à évaluer le délai d’arrivé du bolus d’indicateur par rapport au modèle de Fermi. De plus l’approche Bayésienne apporte en supplément des informations intéressantes telles que la fonction de densité de probabilité de la mesure et l’incertitude sur la fonction résidu qui permettent de connaitre la fiabilité de la mesure effectuée notamment en observant la répartition de la fonction de densité de probabilité de la mesure. Enfin, nous avons proposé un algorithme de segmentation des lésions myocardiques, exploitant les dimensions spatiotemporelles des données de perfusion. Cette technique permet une segmentation objective et précise de la région hypoperfusée permettant une mesure du flux sanguin myocardique sur une zone de tissu dont le comportement est homogène et dont la mesure du signal moyen permet une augmentation du rapport contraste à bruit. Sur la cohorte de 30 patients, la variabilité des mesures du flux sanguin myocardique effectuées sur les voxels détectés par cette technique était significativement inférieure à celle des mesures effectuées sur les voxels des zones définies manuellement (différence moyenne=0.14, 95% CI [0.07, 0.2]) et de celles effectuées sur les voxels des zones définies à partir de la méthode bullseye (différence moyenne =0.25, 95% CI [0.17, 0.36]) / Cardiovascular diseases and in particular coronary heart disease are the main cause of death worldwide with 17.9 million deaths in 2012. Cardiac MRI is a particularly interesting tool for understanding and evaluating heart disease, including ischemic heart disease. Its diagnostic contribution is often major and it provides information that is not accessible by other imaging modalities. The work carried out during this thesis focuses more specifically on the so-called myocardium perfusion test, which consists in studying the distribution of a contrast agent within the heart muscle during its first passage. In clinical practice, this examination is often limited to the clinician's visual analysis, allowing him to identify the culprit artery and deduce the impacted territory. However, this technique is relative and does not quantify myocardial blood flow. In recent years, an increasing number of techniques have emerged to enable this quantification at all stages of processing, from acquisition to the measurement itself. We first established a treatment pipeline to combine these approaches and evaluate them using a digital phantom and clinical data. We demonstrated that the Bayesian approach is able to quantify myocardium perfusion and its superiority in evaluating the arrival time of the indicator bolus compared to the Fermi model. In addition, the Bayesian approach provides additional interesting information such as the probability density function of the measurement and the uncertainty of the residual function, which makes it possible to know the reliability of the measurement carried out, in particular by observing the distribution of the probability density function of the measurement. Finally, we proposed an algorithm for segmentation of myocardial lesions, using the spatial and temporal dimensions of infusion data. This technique allows an objective and precise segmentation of the hypoperfused region allowing a measurement of myocardial blood flow over an area of tissue which behavior is homogeneous and which average signal measurement allows an increase in the contrast-to-noise ratio. In the cohort of 30 patients, the variability of myocardial blood flow measurements performed on voxels detected by this technique was significantly lower than that of measurements performed on voxels in manually defined areas (mean difference=0.14, 95% CI[0.07, 0.2]) and those performed on voxels in areas defined using the bullseye method (mean difference=0.25, 95% CI[0.17, 0.36])
844

Novel molecular mechanisms of neuronal and vascular protection in experimental glaucoma

Almasieh, Mohammadali 04 1900 (has links)
No description available.
845

Adhesion of Rolling Cell to Deformable Substrates in Shear Flow

Moshaei, Mohammad Hossein 01 October 2018 (has links)
No description available.
846

Access Blood Flow Measurement Using Angiography

Koirala, Nischal 26 September 2018 (has links)
No description available.
847

Impaired cardiovascular responses to glucagon-like peptide 1 in metabolic syndrome and type 2 diabetes mellitus

Moberly, Steven Paul 30 January 2013 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Recent advancements in the management of systemic glucose regulation in obesity/T2DM include drug therapies designed to utilize components of the incretin system specifically related to glucagon-like peptide 1 (GLP-1). More recently, GLP-1 has been investigated for potential cardioprotective effects. Several investigations have revealed that acute/sub-acute intravenous administration of GLP-1 significantly reduces myocardial infarct size following ischemia/reperfusion injury and improves cardiac contractile function in the settings of coronary artery disease, myocardial ischemia/reperfusion injury, and heart failure. Despite an abundance of data indicating that intravenous infusion of GLP-1 is cardioprotective, information has been lacking on the cardiac effects of iv GLP-1 in the MetS or T2DM population. Some important questions this study aimed to address are 1) what are the direct, dose-dependent cardiac effects of GLP-1 in-vivo 2) are the cardiac effects influenced by cardiac demand (MVO2) and/or ischemia, 3) does GLP-1 effect myocardial blood flow, glucose uptake or total oxidative metabolism in human subjects, and 4) are the cardiac effects of GLP-1 treatment impaired in the settings of obesity/MetS and T2DM. Initial studies conducted in canines demonstrated that GLP-1 had no direct effect on coronary blood flow in-vivo or vasomotor tone in-vitro, but preferentially increased myocardial glucose uptake in ischemic myocardium independent of effects on cardiac contractile function or coronary blood flow. Parallel translational studies conducted in the humans and Ossabaw swine demonstrate that iv GLP-1 significantly increases myocardial glucose uptake at rest and in response to increases in cardiac demand (MVO2) in lean subjects, but not in the settings of obesity/MetS and T2DM. Further investigation in isolated cardiac tissue from lean and obese/MetS swine indicate that this impairment in GLP-1 responsiveness is related to attenuated activation of p38-MAPK, independent of alterations in GLP-1 receptor expression or PKA-dependent signaling. Our results indicate that the affects of GLP-1 to reduce cardiac damage and increase left ventricular performance may be impaired by obesity/MetS and T2DM.
848

A 37-Year-Old Man With Severe Head Trauma, and A "Hot Nose" Sign on Brain Flow Study

Baron, M, Brasfield, J 01 November 1999 (has links)
No description available.
849

Quantification of cerebral blood flow with 15O-water PET : A comparison study between PET/CT and PET/MR and two different blood sampling instruments

Eriksson, Amanda January 2021 (has links)
Cerebral blood flow quantification is a vital diagnostic tool for disease monitoring and used for diagnosing a variation of pathological conditions. The human brain requires roughly about 20 % of the total cardiac output to sustain normal functioning, hence the perfusion of blood is an important factor to deliver oxygenated blood. The golden standard for quantifying the cerebral blood flow follows by measurement with dynamic positron emission tomography of 15O-labelled water modelled by tracer kinetic compartments. For implementation, knowledge of an input function must exist which is in general being sampled through arterial cannulation of the radial artery with a continuous sampling instrument. The core of this thesis is to establish if two sampling instruments contradicts in comparison to each other when sampling the data to the input function.  In total 22 subjects underwent a 10-minute dynamic  15O-labeled water brain PET scan on two imaging modalities PET/CT and PET/MR. Continuous arterial sampling was performed either by a Veenstra on PET/CT or a Swisstrace on PET/MR during a baseline scan. In two subjects the two sampling instruments were coupled in series and imaged solely on the PET/CT.  Cerebral blood flow analysis was done comparing varying dispersion times, the two imaging modalities compared each other and comparing the calculated and measured blood flows obtained through this study with the values obtained prior. To be able to compare the values showing inconsistency to the values obtained through this thesis, a comparison between two different iterative reconstruction methods was done. Here the method of ordered subsets expectation maximum was compared to a Bayesian penalized-likelihood method. To further compare the two sampling instruments an image derived input function was constructed and compared with the blood sampled input function. The results showed that there was no significant difference between measured cerebral blood flow between the two imaging modalities with the currently used reconstruction method based on Bayesian penalized likelihood but presented in the earlier data there was an inconsistency. A dispersion analysis with variation on the external dispersion time shows that if the time was chosen to low or to high compared to the standard time used it introduced distorted fitted models of the activity curves. This distortion creates further errors in the calculation of the cerebral blood flow, however with the analysis the standard dispersion time could be confirmed as an accurate fit. Subjects imaged with the two sampling instruments in series showed no significant difference except for the measured values on Veenstra to be slightly higher. Lastly the correlation between the image derived input function and the blood sampled input function showed poorly performance. Only a R2 value of 0.42 was achieved on the PET/CT while a meagre R2 value of 0.18 was achieved on the PET/MR. Although the correlation was poorly, the plotted activity curves from the two functions showed a representable appearance between each other. / Kvantifiering av det cerebrala blodflödet är ett nödvändigt diagnostiskt verktyg som används för att kontrollera och diagnostisera en variation av patologiska sjukdomstillstånd. Den mänskliga hjärnan kräver kring 20 %av den totala produktionen från hjärtat för att upprätthålla normal funktion, följaktligen är perfusion av blod en viktig faktor för att distribuera syrerikt blod runt om i kroppen. Den gyllene standarden för kvantifiering av det cerebrala blodflödet följer som undersökning med dynamisk positron emission tomografi av 15O-märkt vatten, modellerat  med kinetisk kompartment teori. För att kunna implementera detta måste information om en input-funktion erhållas, generellt erhålls detta genom att blod tags genom arteriell kanylering av antingen den radiella artären med ett kontinuerligt samplings instrument. Målet med detta arbete är att fastställa om två samplings instrument motsäger varandra vid mätning av data till input-funktionen. Totalt deltagande är 22 patienter som genomgick en 10-minuters dynamisk 15O-märkt vatten PET undersökning av hjärnan på två bildtagningsmodaliteter PET/CT och PET/MR. Kontinuerlig blodtagning genomfördes antingen med en Veenstra sampler instrument på PET/CT eller en Swisstrace sampler instrument på PET/MR tillsammans med en baseline undersökning. Vid två undersökningar seriekopplades de två instrumenten och patienterna blev endast undersökta vid PET/CT. För ytterligare kunna utvärdera de två instrumenten, konstruerades en bild framtagen input-funktion som sedan kunde jämföras med den blod samplade input-funktionen. Cerebrala blodflödes analyser gjordes med olika dispersions tider, även för att kunna jämföra de två bildtagningsmodaliteterna mot varandra och jämföra erhållna värden framtagna under denna studie med en tidigare studie. För att kunna jämföra avvikelserna i de uppmätta värdena har även två olika rekonstruerings metoder studerats. Resultaten visar ingen signifikant skillnad mellan de uppmätta cerebrala blodflödena mellan de två bildtagningsmodaliteterna rekonstruerade med den nuvarande standarden. Dispersions analysen med varierande extern dispersions tid visar att om tiden är för kort eller för lång jämfört med standardtiden, introduceras en osann anpassning av aktivitets kurvorna. Denna förvrängning av datat resulterar till fler avvikelser i beräkningarna av blodflödet, likväl var det möjligt att bekräfta standardtiderna som används. Patienter som undersöktes med instrumenten i seriekoppling visade ingen signifikant skillnad förutom att det uppmättes en aningens högre värden hos patienter med Veenstra som blod sampler. Slutligen, korrelationen mellan den bild framtagna input-funktionen och den blod samplade input-funktionen visade ett dåligt resultat. Endast ett R2 värde på 0.42 erhölls för PET/CT medan endast ett R2 värde på 0.18 på PET/MR erhölls. Trotts att korrelationen var dålig, visade de plottade aktivitets kurvorna ett representativt utseende mellan de två typerna av input funktion.
850

Altération du couplage neurovasculaire par l'interleukine-17A : implication dans l'hypertension artérielle et en fonction du statut sexuel et hormonal

Youwakim, Jessica 08 1900 (has links)
Les maladies cardiovasculaires et neurodégénératives sont associées à un déséquilibre entre les cellules immunitaires pro et anti-inflammatoires, en faveur d'une plus grande production de cytokines pro-inflammatoires. Plus spécifiquement, l’interleukine (IL)-17A semble jouer un rôle essentiel dans le développement et la progression de ces pathologies, notamment par des niveaux plus élevés d’IL-17A circulants. Toutefois, les mécanismes précis de son action demeurent en grande partie méconnus. De plus, l’influence du sexe et du statut hormonal sur l'action de l'IL-17A dans ces pathologies demeurent un domaine peu exploré. Cette lacune soulève plusieurs questions quant à la manière dont l'IL-17A influence le développement et la progression de ces maladies, et ce, peu importe le sexe. Les vaisseaux sanguins servent d’interface entre le système immunitaire périphérique et le cerveau et un débit sanguin cérébral optimal est indispensable au maintien de l’homéostasie cérébrale. Un des principaux mécanismes de régulation du débit sanguin cérébral est le couplage neurovasculaire, qui relie l’augmentation du débit sanguin à l’activité neuronale. De ce fait, l’objectif principal de cette thèse consiste à approfondir nos connaissances concernant l’impact de l’IL-17A sur l’altération du couplage neurovasculaire causée par un modèle d’hypertension artérielle induite par l’angiotensine (Ang) II. Nous avons ensuite évalué l’impact de l’IL-17A sur le couplage neurovasculaire en tenant compte de l’influence du sexe et du statut hormonal. Nous avons aussi cherché à approfondir nos connaissances sur les mécanismes qui sous-tendent l’action de l’IL-17A sur la fonction cérébrovasculaire. Nos travaux mettent en évidence le rôle essentiel de l'IL-17A en tant que médiateur de l’altération du couplage neurovasculaire par l’Ang II chez les souris mâles. L’action de l’IL-17A passe par la production d’anions superoxydes issus de la NADPH oxydase de type 2. De façon intéressante, les souris femelles, contrairement aux mâles, semblent bénéficier d’une protection contre l’altération du couplage neurovasculaire et de l’augmentation de la production d’anions superoxydes induites par l’IL-17A. Cette protection découle des propriétés anti-inflammatoires et antioxydantes de l’estradiol et de son interaction avec les récepteurs à l’œstrogènes ERβ et GPER. Les résultats démontrés dans cette thèse ont permis d’élargir notre compréhension de la relation entre les cytokines inflammatoires, la circulation cérébrale, et l'influence du sexe et du statut hormonal, ouvrant ainsi la porte à un domaine de recherche jusqu’à maintenant peu exploré. / Cardiovascular and neurodegenerative diseases are linked to an imbalance between pro- and anti-inflammatory immune cells in favor of a greater production of pro-inflammatory cytokines. Specifically, interleukin (IL)-17A appears to play a crucial role in the development and progression of these conditions, characterized by elevated circulating levels of IL-17A. However, the precise mechanisms underlying its action remain largely unknown. Furthermore, the influence of sex and hormonal status on the function of IL-17A in these diseases has yet to be investigated. This raises several questions concerning the impact of IL-17A in the development and progression of these diseases in both sexes. Blood vessels serve as the interface between the peripheral immune system and the brain, and optimal cerebral blood flow is essential for maintaining cerebral homeostasis. One of the main mechanisms of cerebral blood flow regulation is neurovascular coupling, which links blood flow to neuronal activity. Thus, the primary objective of this thesis is to deepen our understanding of the impact of IL-17A on neurovascular coupling impairment induced by angiotensin (Ang) II in the context of arterial hypertension while taking into consideration sex and hormonal status. Lastly, we gained a more comprehensive understanding of the mechanisms underlying IL-17A's actions on the cerebrovascular function. Our discoveries highlight the crucial role of IL-17A as a mediator in Ang II-induced neurovascular coupling impairment in male mice. The action of IL-17A involves the production of superoxide anions derived from type 2 NADPH oxidase. Interestingly, female mice, unlike males, appear to be protected from the IL-17A-induced neurovascular coupling impairment and increased superoxide anions production. This protection stems from the anti-inflammatory and antioxidant properties of estradiol acting via the estrogen receptors ERβ and GPER. In conclusion, the discoveries presented in this thesis broadened our comprehension of the relationship between inflammatory cytokines, cerebral circulation, and the influence of sex and hormonal status, thus paving the way for previously underexplored field of research.

Page generated in 0.046 seconds