Spelling suggestions: "subject:"bond strength"" "subject:"fond strength""
131 |
Influência do acabamento e polimento de resina composta na resistência adesiva à dentina e no ângulo cavo-superficial em esmalte / The influence of finishing and polishing procedures on dentin bond strength of resin composite and at the interface enamel/restorationDiego Ferreira Regalado 17 August 2007 (has links)
O objetivo desse trabalho foi verificar a influência do procedimento de acabamento e polimento das restaurações de resina composta na resistência adesiva à dentina, através de testes de microtração, assim como, analisar em microscopia eletrônica de varredura a interface dente/restauração no nível do ângulo cavo-superficial. Terceiros molares humanos extraídos e hígidos foram utilizados nesse estudo, após aprovação pelo Comitê de Ética em Pesquisa da FOB-USP. Os dentes foram restaurados com sistema adesivo Solobond M (VOCO) e resina composta Grandio (VOCO) e distribuídos nos seguintes grupos: G1 (controle) - sem acabamento e polimento, G2 - acabamento e polimento imediato, G3 - sem acabamento e polimento e armazenado por sete dias e G4 - acabamento e polimento após sete diasem estufa a 37ºC. Palitos com dimensões de 1mm x 1mm foram obtidos e submetidos a uma força de tração em uma máquina de ensaios universal EMIC à velocidade de 0.5mm/min. Para a análise em microscopia eletrônica de varredura, 20 terceiros molares receberam quatro preparos cavitários com 1mm de diâmetro e 3mm de altura que foram restaurados com o mesmo sistema restaurador utilizado para os testes de resistência adesiva e distribuídos nos mesmos grupos descritos acima. Após a obtenção dos espécimes de cada grupo, os dentes foram metalizados e analisados na interface dente/restauração em microscopia eletrônica de varredura por três examinadores. As médias de resistência adesiva (MPa) e respectivos desvios-padrão foram: G1 - 23,05 (8,62); G2 - 17,34 (6,11); G3 - 21,64 (7,63) e G4 - 18,12 (6,51). Os valores de resistência adesiva submetidos à Anova a um critério e teste de Fisher permitiram concluir que o procedimento de acabamento e polimento das restaurações de resina composta diminuiu significativamente a resistência adesiva à dentina. O teste de Kruskal-Wallis aplicado aos escores obtidos da análise das fendas no ângulo cavo-superficial permitiu determinar que o acabamento e polimento da resina composta não interfere na formação de fendas. / The objective of this study was to verify the influence of finishing and polishing procedures on dentin bond strength of resin composite, and at the interface tooth/restoration using MEV. Recently extracted human third molars were utilized in this study, after approved by ethics and search committee at FOB-USP. The teeth were restored with Solobond M (VOCO) adhesive system and resin composite Grandio (VOCO) and randomized in the follow groups: G1 (control) - no polishing and finishing, G2 - immediate polishing and finishing procedures, G3 - no polishing and finishing and stored for seven days e G4 - polishing and finishing procedures after seven days under water at 37oC. Sticks 1mm x 1mm were obtained and the bonds were then stressed to failure by microtensile forces in a EMIC universal testing machine at a crosshead speed of 0.5 mm/min. Twenty human third molars were prepared with four cavities with 1mm diameter and 3mm height and restored with the same restoration system used for the microtensile tests and were distributed at the same groups and the interface tooth/restoration was analyzed in MEV by three examinators. The means of bond strength (MPa) and respective standard deviation were: G1 - 23.05 (8.62); G2 - 17.34 (6.11); G3 - 21.64 (7.63) e G4 - 18.12 (6.51). The data were analyzed by One-Way Anova and e Fisher´s test. It was possible to conclude that the finishing and polishing procedures of resin composite decrease significantly the bond strength to dentin of the composite restorations. The Kruskal- Wallis test aplicated to gap scores at the tooth/restoration interface allows to determinate that the finishing and polishing procedures of resin composite do not interfere in gap formation.
|
132 |
Avaliação da resistência adesiva à dentina tratada pela terapia fotodinâmica em dente bovino / Evaluation of the bond strength to dentin treated by photodynamic therapy in bovine toothChristian Giancarlo Bernal Rodriguez 17 January 2017 (has links)
A Terapia fotodinâmica (TF) é uma técnica que combina a ativação de um fotossensibilizador por luz na presença de oxigênio, produzindo radicais que induzem a morte celular dos microrganismos. Esta terapia vem sendo usada para reduzir a quantidade de microrganismos sendo um potencial antimicrobiano nos tecidos cariados em um processo restaurador direto, evitando assim o processo de cárie recidivante que pode acontecer quando não se promove a eliminação dos restos de microrganismo remanescentes após a utilização dos instrumentos rotatórios. O objetivo deste estudo in vitro foi avaliar a resistência de união de dois sistemas adesivos (condicionamento total e autocondicionante), sobre a superfície de dentina bovina, após tratamento com terapia fotodinâmica. Foi feito ensaio de microcisalhamento com o objetivo de avaliar a resistência de união. Para a realização da terapia fotodinâmica foi usado azul de metileno a 0,01% e duas fontes de luz diferentes, laser vermelho (660 nm) e LED (645-630 nm), com parâmetros já testados em estudos anteriores e, atualmente, utilizados na clinica odontológica. Para avaliar a resistência de união foi utilizado ensaio mecânico de microcisalhamento e, para isso, se utilizou sessenta discos de dentina, obtidos a partir de sessenta incisivos centrais bovino íntegros. Após o desgaste da dentina, as amostras foram dividas aleatoriamente em 6 grupos, sendo n=10 para o ensaio de microcisalhamento (G1: adesivo autocondicionante Single Bond Universal (USB) sem PDT, G2: PDT com laser + USB, G3: PDT com LED + USB; G4: adesivo de condicionamento total com Adper Single Bond 2 (ASB) sem PDT; G5: PDT com laser + ASB¸ G6: PDT com LED + ASB). Em cada amostra foram confeccionados 03 cilindros de resina composta, os quais foram submetidos à avaliação de microcisalhamento (1 mm/min); após armazenamento em saliva artificial por 24 horas. Após este teste, as amostras foram levadas em lupa estereoscópica (40x) para análise do padrão de fratura. Os resultados do teste de resistência de união foram tabulados e submetidos ao teste ANOVA dois fatores (adesivo e tratamento) e Tukey adotando-se um nível de significância de 5%. Quanto à resistência de união, não houve diferença significativa entre os 6 grupos analisados. Houve predominância de padrão de fratura do tipo adesiva. Com base nos resultados e nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que não existe alteração na força de adesão da resina na dentina hígida após tratamento com PDT. / Photodynamic Therapy (PDT) is a technique that combines the activation of a photosensitizer by light in the presence of oxygen, producing radicals that induce cell death of the microorganisms. This therapy has been used to reduce the amount of microorganisms being an antimicrobial potential in the decayed tissues in a direct restorative process, thus avoiding the process of recurrent caries that can happen when the elimination of remaining remains of microorganism after the use of the instruments is not promoted. The objective of this in vitro study was to evaluate the bond strength and morphology of the hybrid layer of two adhesive systems (Self-etch and total etch) on the bovine dentin surface, after treatment with photodynamic therapy. A micro-shear test was performed in order to evaluate the bond strength. To perform the photodynamic therapy, 0.01% methylene blue and two different light sources, red laser (660 nm) and LED (645-630 nm) were used, with parameters already tested in previous studies and currently used in the dental clinic. In order to evaluate the bond strength, a microshear bond strenght test was used. For this purpose, sixty dentin disks were obtained from sixty complete central incisors. After dentin wear, the samples were randomly divided into 6 groups, with n = 10 for the micro bond strenght test (G1: Self-etch adhesive, single bond Universal (USB) without PDT, G2: PDT with laser + USB, G3: PDT with LED + USB; G4: total etch adhesive Single Bond 2 (ASB) without PDT; G5: PDT with laser + ASB¸ G6: PDT with LED + ASB). In each sample, 03 cylinders of composite resin were made, which were submitted to the evaluation of micro-shear strenght test (1 mm / min); after storage in artificial saliva for 24 hours. After this test, the samples were taken in a stereoscopic magnifying glass (40x) for analysis of the fracture pattern. The results of the Microshear bond strength test were tabulated and submitted to ANOVA two-factor test (adhesive and treatment) and Tukey adopting a significance level of 5%. Regarding the bond strength, there was no significant difference between the 6 groups analyzed. There was a predominance of an adhesive type fracture pattern. Based on the results and the irradiation parameters used in this study, it can be concluded that there is no alteration in the adhesion strenght of the resin in a healthy dentin after treatment with PDT.
|
133 |
Influência da aplicação de um inibidor de metaloproteinases na resistência da união adesiva à dentina radicularLeitune, Vicente Castelo Branco January 2010 (has links)
O objetivo do presente estudo foi avaliar o efeito da aplicação de clorexidina após o condicionamento ácido na preservação da camada híbrida, avaliando a resistência de união imediata e a longo prazo de pinos de fibra de vidro cimentados à dentina radicular. Setenta e dois dentes unirradiculares superiores humanos foram selecionados. Os canais radiculares foram alargados para receberem os pinos de fibra de vidro e aleatoriamente divididos em três grupos (n=24). No Grupo Controle (Gcontrol), o pino de fibra de vidro foi cimentado de acordo com as instruções do fabricante, utilizando um sistema adesivo convencional de três passos e um cimento resinoso dual. Os grupos tratados com digluconato clorexidina GCHX0.2 e GCHX2 receberam a aplicação de solução de clorexidina 0,2% e 2%, respectivamente, após o condicionamento com ácido fosfórico e os pinos foram cimentados utilizando o mesmo sistema adesivo e cimento utilizados no Gcontrol. As raízes foram seccionadas transversalmente ao longo eixo do dente, em fatias de 0,68 (± 0,09) mm. Metade dos dentes foi submetida ao ensaio de push-out após 24 horas e a outra metade, após seis meses de armazenamento em água destilada, a 37°C. Os valores foram analisados com ANOVA de duas vias e teste de comparações múltiplas de Tukey, com nível de significância de 5%. A aplicação de clorexidina não influenciou a resistência de união quando os dentes foram avaliados no mesmo período de armazenagem (p>0,05). O tempo de armazenamento diminuiu significativamente a resistência de união de 24 horas para 6 meses, em todos os grupos (p<0,05). A aplicação de clorexidina não preveniu significativamente a degradação da resistência de união de pinos de fibra cimentados em raízes de dentes humanos, após seis meses de armazenamento. / Introduction: This study evaluated the effect of chlorhexidine applied after dentin phosphoric acid etching on hybrid layer preservation, analyzing the immediate and long-term bond strength of a fiber post cemented to root dentin. Methods: Seventy-two single-rooted, human upper teeth were selected for analysis. Root canals were enlarged for fiber post cementation and were randomly divided into three groups (n= 24). After phosphoric acid etching, each group received a different dentin treatment. In the Control Group (Gcontrol), the fiber post was cemented according to the manufacture’s instruction, using a three-step etch-and-rinse adhesive and a dual-cured resin cement. The Chlorhexidine 0.2% Group (GCHX 0.2) and the Chlorhexidine 2% Group (GCHX 2) received an application of a chlorexidine digluconate solution of 0.2% and 2%, respectively, after phosphoric acid etching, and the post was cemented using the same adhesive and cement that was used in the Gcontrol. Teeth were sectioned transversally in slices of 0.68 (± 0.09) mm. Half of the teeth were submitted to push-out bond strength after 24 hours and the other half were submitted after six months of distilled water storage at 37°C. Data were analyzed by using the two-way analysis of variance (ANOVA) and a post hoc tests using the Tukey multiple comparison test at α = 0.05. Results: Chlorhexidine application had no influence on bond strength when teeth were stored for the same period of time (p>0.05). The storage time significantly decreased the bond strength values of 24 hours to six months, in all groups (p<0.05). Conclusion: After six months, chlorhexidine application did not effectively arrest bond strength degradation of fiber post cemented in human roots.
|
134 |
Resistência de união da interface coping cerâmico pilar de implante variando o agente cimentante antes e após ciclagem térmica / Bond strength of the ceramic coping-implant abutment interface varying luting agent before and after thermal cyclingWashington dos Reis Leite 25 October 2010 (has links)
Objetivo: O objetivo do presente estudo foi avaliar a resistência de união da interface coping cerâmico-pilar de implante variando o agente cimentante antes e após ciclagem térmica. Material e métodos: Foram utilizados quarenta conjuntos de copings cerâmicos e.max - pilar sólido 5.5/ análogo regular, sendo estes divididos aleatoriamente de acordo com o agente cimentante (n=10): (OZ) óxido de zinco sem eugenol; (FZ) fosfato de zinco; (CIV) ionômero de vidro modificado por resina; (RES) resinoso autopolimerizável. O teste de resistência da união à tração foi executado em uma máquina de ensaios universal (Versat 2000-Panambra), com velocidade de 1,0mm/min, antes e após ensaio de envelhecimento por ciclagem térmica. Os resultados foram submetidos ao teste de normalidade e posteriormente a ANOVA (two-way) e teste de Tukey, com nível de significância de 5%. Resultados: Antes da ciclagem térmica, os valores variaram entre o mínimo de 50,77N (OZ) e o máximo de 240,21N (CIV). Não foi observada diferença entre OZ e FZ (60,16N), nem entre CIV e RES (230,36N). Após a ciclagem térmica, os valores foram de no mínimo 3,5N (OZ) e máximo de 330,66N (RES). OZ apresentou resultados estatísticamente inferiores se comparado aos demais, enquanto RES obteve resultados estatísticamente superiores em relação aos demais agentes cimentantes, FZ (90,58N) e CIV (280,43N) apresentaram resultados intermediários. Conclusões: O cimento de óxido de zinco sem eugenol foi associado ao pior desempenho comparado aos demais agentes avaliados antes e após a ciclagem. Antes da ciclagem térmica o maior valor médio obtido foi do ionômero de vidro, enquanto que após a ciclagem o maior valor médio foi do cimento resinoso. O envelhecimento das amostras promoveu inversão dos resultados do ionômero e resinoso, com melhor resultado mecânico para o cimento resinoso. / Objective: The aim of the present study was to evaluate the bond strength of the ceramic coping-abutment implant interface according to the luting agent, before and after thermal cycling. Methods: A total of forty sets of ceramic copings (IPS e.max) and solid pillar 5.5/ regular analogue were divided according to the luting agent (n=10): (OZ) zinc oxide with no eugenol; (ZP) zinc phosphate, (CIV) resin modified glass ionomer, (RES) adhesive resin cement. Tensile bond strength test was performed using a universal testing machine (2000-Versat Panambra) with a speed of 1.0mm/min, before and after thermal cycling. Results were submitted to normality test and then analyzed by ANOVA and Tukey test with significance level of 5%. Results: Prior to thermal cycling, values ranged from 50.77N (OZ) to 240.21N (CIV). No difference was observed between OZ and FZ (60.16N), nor between CIV and RES (230.36N). After thermal cycling, values ranged between 3.5N (OZ) and 330.66N (RES). OZ showed statistically lower mean values compared to the others. RES presented statistically higher mean values in comparison to the other luting agents. FZ (90.58N) and CIV (280.43N) showed intermediate results. Conclusions: Zinc oxide with no eugenol was associated with the worst performance compared to the other agents after thermal cycling. Before thermal cycling the highest mean value was obtained for the glass ionomer. However, after this step, adhesive resin cement showed the highest mean value of bond strength. The sample aging inverted results between ionomer and resin cement, with better mechanical performance for the resin cement.
|
135 |
Influência do posicionamento do espécime na resistência adesiva à dentina e na espessura da camada de sistemas adesivos / Influence of dentin surface inclination on bond strength and adhesive layer thicknessFlavia Bittencourt Pazinatto 06 April 2006 (has links)
Investigou-se a influência da inclinação das paredes de dentina (paralela ou perpendicular à ação da gravidade) e da variação regional dos espécimes (terços cervical ou oclusal) na resistência adesiva e na espessura da camada de adesivo. Vinte e cinco molares humanos foram seccionados no sentido mésio-distal e paralelamente ao seu longo eixo, obtendo-se secções vestibulares e linguais, as quais foram lixadas produzindo-se superfícies planas de dentina. Sistemas adesivos (Adper Single Bond-SB e Prime & Bond 2.1- PB2.1) foram aplicados na dentina, ora paralelamente ora perpendicularmente à ação da gravidade, padronizando-se o volume de adesivo (3,5 µl por gota) através do uso de uma micropipeta e seguindo-se as instruções dos fabricantes. Os grupos de estudo foram: 1A (SB, paralelo), 1B (SB, perpendicular), 2A (PB2.1, paralelo) e 2B (PB2.1, perpendicular). Após 24h de armazenamento em água deionizada a 37°C, espécimes foram preparados na forma de palitos de dentina com área adesiva de 0,8 mm2, aproximadamente. Na seqüência, foi determinada a espessura do adesivo de cada espécime, em micrômetros (µm), sob microscopia óptica (200X de aumento) e auxílio do programa Image Pro-Plus 4.5. Posteriormente, os espécimes foram submetidos à microtração sob velocidade de 0,5 mm/min. Todos os espécimes fraturados foram examinados sob microscopia óptica (40X de aumento) para a determinação dos planos de fratura. Os dados coletados foram submetidos aos testes ANOVA a 1 e 2 critérios e SNK (? = 0,05). Para determinação da correlação entre resistência adesiva e espessura do adesivo foi utilizado o teste de Correlação de Pearson. Os valores médios (MPa±d.p.) de resistência adesiva dos grupos 2A (52,93±15,19) e 2B (52,27±16,54) foram superiores àqueles dos grupos 1A (39,09±12,90) e 1B (32,94±12,42), independente da inclinação das paredes de dentina dos mesmos. Não houve diferença nos valores de resistência adesiva à dentina, independente da variação regional do espécime. Os valores médios (µm±d.p.) de espessura da camada de adesivo dos grupos 1A (11,24±2,92) e 1B (18,11±7,31) foram superiores àqueles dos grupos 2A (4,20±1,81) e 2B (3,87±1,29) (p > 0,05). O grupo 1B promoveu os maiores valores de espessura de adesivo, seguido do grupo 1A. As espessuras do adesivo nos grupos 2A e 2B apresentaram-se similares entre si. Houve influência da variação regional do espécime na espessura de adesivo somente para o grupo 1B. Não houve correlação entre resistência adesiva e espessura de adesivos para ambos SB e PB2.1 (r = -0,224, p = 0,112 e r = 0,099, p = 0,491, respectivamente). Conclui-se que a influência da inclinação das paredes de dentina e da variação regional dos espécimes na espessura da camada de adesivo é material-dependente, porém não influem na resistência adesiva dos sistemas adesivos à dentina. / To determine the effect of the inclination of dentin surfaces (parallel or perpendicular to the force of gravity) and the regional variation of specimens (cervical or occlusal thirds) on the dentin bond strength and adhesive layer thickness. Twenty-five extracted human molars were sectioned in a mesio-distal direction to expose flat dentin. Standardized drop volumes of adhesive systems (Single Bond-SB and Prime & Bond 2.1-PB2.1) were applied to dentin according to manufacturers instructions. Teeth were randomly divided into the following groups: 1A (SB, parallel), 1B (SB, perpendicular), 2A (PB2.1, parallel) and 2B (PB2.1, perpendicular). Teeth were stored in 37°C distilled water for 24h and then serially sectioned to obtain sticks with cross-sectional area of approximately 0.8 mm2 for microtensile bond strength test (MTBS). The thickness of adhesive layer of the MTBS specimen was determined in a light microscope at 200X magnification. Forty-eight hours after adhesion procedures the specimens were subjected to MTBS at a crosshead speed of 0.5 mm/min. After testing, the fracture modes of each specimen were determined by examination under a 40X magnification. One and two-way ANOVA and Student- Newman-Keuls-SNK tests were performed do determine differences in MTBS and in adhesive layer thickness among groups. The correlation between MTBS and adhesive layer thickness was compared with Pearson Product Moment Correlation ('alfa' = 0.05). Mean values (MPa±s.d.) for bond strength were higher for groups 2A (52.93±15.19) and 2B (52.27±16.54) than for groups 1A (39.09±12.90) and 1B (32.94±12.42), regardless of the position of dentin surfaces. There was no difference in MTBS, despite the regional variation of specimens. The thickness of adhesive systems (µm±s.d.) was higher for groups 1A (11.24±2.92) and 1B (18.11±7.31) than those for groups 2A (4.20±1.81) and 2B (3.87±1.29). Group 1B provided the greater mean values of adhesive thickness followed by the Group 1A. Similar adhesive thicknesses were found for Groups 2A and 2B, but significantly lower than the other groups. There was a significant influence of the regional variation of specimens on the adhesive thickness of group 1B. No correlation was found between bond strength and adhesive layer thickness for both SB and PB 2.1 (r = -0.224, p = 0.112 and r = 0.099, p = 0.491, respectively). The inclination of dentin surface and the regional variation of specimens on the adhesive layer thickness are materialdependent. These variables do not influence the adhesive systems bond strength to dentin.
|
136 |
Resistência de união entre cimentos resinosos e zircônia / Bond strenght between resin cements and zirconiaJuan Rommel Medina Valdivia 18 August 2011 (has links)
Este estudo avaliou a resistência de união de cimentos resinosos à zircônia tetragonal parcialmente estabilizada com ítrio (NobelProceraTM Zircônia) submetida a tratamentos superficiais mecânicos e químicos. Os cimentos utilizados foram o cimento resinoso auto-condicionante de polimerização química Multilink (Ivoclar Vivadent) associado ao Metal/Zirconia Primer (Ivoclar Vivadent) e o cimento resinoso auto-adesivo de polimerização química e dual RelyX U100 (3M-ESPE) associado ao adesivo Adper Single Bond Plus 2 (3M-ESPE). Utilizando 40 cilindros de zircônia (diâmetro de 3,5 mm) foram realizados 120 ensaios (n=40 para cada cimento). Para cada cimento os cilindros foram divididos em 4 grupos (n=10) em função do tratamento superficial avaliado: 1- sem tratamento; 2- agente de união (primer ou adesivo); 3- jateamento com oxido de alumínio 50µm; 4- associação do jateamento e o agente de união. A aplicação do cimento resinoso foi realizada utilizando uma matriz de teflon com orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Após a aplicação de cada cimento nas 4 condições de superficie, os espécimes foram armazenados em água deionizada a 37ºC durante 24h e submetidos ao teste de resistência ao cisalhamento. Os resultados foram analisados com ANOVA a dois critérios e teste de Tukey (p<0,05). Sem tratamento superficial o RelyX U100 químico (5,52 Mpa) e dual (6,53 Mpa) tiveram melhor comportamento que o cimento Multilink (0,76). A associação do jateamento e o agente de união melhorou os valores de resistência de união para o cimento Multilink (7,68 Mpa) e para o cimento RelyX U100 dual (10,26 Mpa), sendo este último superior a todos os outros grupos. A associação do Adper Single Bond Plus 2 e o RelyX U100 sem jateamento, deve ser evitado. / The aim of this study was to evaluate the shear bond strength of resin cements to the yttria stabilized tetragonal zirconia (NobelProceraTM Zirconia) subjected to mechanical and chemical surface treatments. The cements used were: a self-etching resin cement with chemical polymerization Multilink (Ivoclar - Vivadent) associated to the Metal / Zirconia Primer (Ivoclar - Vivadent) and self-adhesive resin cement with chemical and dual polymerization RelyX U100 (3M-ESPE) associated to the adhesive Single Bond Plus Adper 2 (3M-ESPE). Using 40 cylinders of zirconia (3.5 mm diameter) were performed 120 trials (n = 40 for each cement). For each cement, cylinders were divided into four groups (n = 10) based on the surface treatment rated: 1 - untreated, 2 - bonding agent (primer or adhesive) 3 air abrasion with 50µm aluminum oxide, 4 - combination of air abrasion and bonding agent. The application of resin cement was performed using a teflon matrix with a central hole 3.5 mm in diameter and 3.0 mm deep. After application of each cement in the four surface conditions, the specimens were stored in deionized water at 37 ° C for 24 hours and tested for shear bond strength. Results were analyzed with an ANOVA Two Criteria and Tukey\'s test (p <0.05). Without surface treatment, chemical RelyX U100 (5.52 MPa) and dual (6.53 MPa) had better behavior than Multilink Cement (0.76). The combination of air abrasion and bonding agent improved the bond strength values for Multilink (7.68 MPa) and for RelyX U100 dual (10.26 MPa), this one superior to all other groups. The association of Adper Single Bond 2 and RelyX U100 Plus without air abrasion, should be contraindicated.
|
137 |
Avaliação da influência do tratamento superficial e do condicionador sobre a resistência ao cisalhamento da união entre uma liga de Co-Cr-Mo e reparos em resina compostaAnderson Pinheiro de Freitas 04 July 2005 (has links)
Para avaliar o efeito de diferentes tratamentos superficiais sobre a resistência ao cisalhamento da união entre uma liga metálica (Co-Cr-Mo - Remanium CD) e uma resina composta (Z-250) e analisar o tipo de fratura durante a separação dos espécimes, sessenta discos metálicos foram fundidos, regularizados e polidos, submetidos a quatro ciclos térmicos (vácuo, 960ºC, 8 minutos) e divididos aleatoriamente em seis grupos. Cada grupo recebeu um tipo de tratamento: Grupo ASB: Asperização com ponta diamantada (No 3118); Grupo ASI: Asperização e aplicação do silano (3M); Grupo AAP: Asperização e aplicação do Alloy Primer (Kuraray); Grupo JSB: Jateamento com óxido de alumínio (50µm, 75lib/pol2); Grupo JSI: Jateamento e aplicação do silano; Grupo JAP: Jateamento e aplicação do Alloy Primer. Todos os espécimes receberam aplicação do adesivo Single Bond e da resina Z-250 (3M), foram armazenados em água deionizada a 37ºC por 24 horas e separados em ensaio de cisalhamento. Os resultados e desvio-padrão de cada grupo, expressos em MPa foram: ASB: 12,708±2,962; ASI: 16,343±2,714 e AAP: 16,723±2,666; JSB: 25,958±5,650; JSI: 28,185±3,322; JAP: 28,670±3,246. Os maiores valores foram produzidos pelos grupos jateados (JSB, JSI e JAP); o silano e o Alloy primer aumentaram a retentividade entre a resina Z-250 e a liga de Co-Cr-Mo, independente da textura superficial e sem apresentar diferença entre os mesmos; todos os espécimes apresentaram falha adesiva na interface testada. / To evaluate the effect of different surface treatments on shear bond strength between a metallic alloy (Co-Cr-Mo - Remanium CD) and a composite resin (Z-250) and to evaluate the fracture mode after testing, sixty disks were casted, polished, submitted to four thermal cycles (960ºC/8min) and divided randomly in six groups. Each group received a different type of treatment: Group ASB: roughen with diamond bur (No 3118); Group ASI: roughen and application of a ceramic Primer; Group AAP: roughen and application of a metallic Primer; Group JSB: Sandblasting with 50 µm aluminum oxide (75lib/pol2); Group JSI: Sandblasting and application of a ceramic Primer; Group JAP: Sandblasting and application of a metallic Primer. All the specimens received the application of an adhesive (Single Bond) and a composite resin (Z-250 /3M). The groups were stored in distilled water at 37ºC during 24 hours and submitted to shear bond strength test. The results and the standard deviation of each group (expressed in MPa) were: JSB: 25,958±5,650; JSI: 28,185±3,322; JAP: 28,670±3,246; ASB: 12,708±2,962; ASI: 16,343±2,714 and AAP: 16,723±2,666. The highest values were obtained by the sandblasted groups (JSB, JSI e JAP). In spite of the surface, ceramic primer and alloy primer increased the retention between the composite resin Z-250 and the Co-Cr-Mo alloy without statistical differences on the results; all of the specimens showed adhesive failures.
|
138 |
Avaliação da influência do choque térmico na aderência dos revestimentos de argamassa. / Evaluation of thermal shock\'s influence on bonding of external mortar renderings.Juan Francisco Temoche Esquivel 30 June 2009 (has links)
Neste trabalho enfoca-se o efeito da variação térmica na degradação da aderência de revestimentos de argamassa. Dentre os diversos fatores que condicionam a aderência dos revestimentos de argamassa, destaca-se aqui o cenário crítico definido pela presença de macrodefeitos na interface revestimento-base e também pela intensidade com que ocorre a variação de temperatura, encontrando-se uma situação extrema quando da ocorrência do choque térmico. Assim, o objetivo desta pesquisa é avaliar, de maneira experimental, o efeito de sucessivos ciclos de choque térmico na resistência de aderência de revestimentos de argamassa, em duas situações limites de taxa de macro-defeitos no contato entre o revestimento e a base e para duas distintas argamassas. Para dar suporte ao trabalho experimental foi elaborado um modelo computacional paramétrico, utilizando modelagem com elementos finitos. Com ele foi possível obter a distribuição de temperaturas, bem como as deformações e tensões geradas no revestimento, variando-se a intensidade do contato revestimento-base e alterandose as características da argamassa de revestimento. A partir de então, definiram-se as variáveis de maior influência e a geometria dos corpos prova, bem como as condições de contorno a serem utilizadas no programa experimental. O programa experimental foi desenvolvido em duas etapas: uma etapa piloto e outra definitiva. Para sua realização foram desenvolvidos e construídos os equipamentos para execução e controle dos ensaios cíclicos de choque térmico. Finalmente, foram realizados ensaios de resistência de aderência do revestimento e avaliados os efeitos de cada uma das variáveis estudadas, empregando-se suporte estatístico. Pelos resultados pode-se comprovar que os macro-defeitos na interface revestimento-base provocam diminuição na resistência de aderência a qual é agravada quando da ocorrência de cíclicos choques térmicos, ocorrendo a situação mais crítica para os revestimentos com maior módulo de elasticidade. / The present study focus on thermal variation effects on mortar rendering bonding degradation. Among the variety of factors that condition the bonding of mortar renderings, a critic scenario can be defined by the existence of interface macro-flaws between mortar rendering and substrate, and by the thermal variation intensity in the extreme situation of thermal shock. This research aims to experimentally evaluate the effects of continuous thermal shock cycles on the bonding strength of mortar renderings in two macro-flaw rate extreme situations in the contact surface between mortar rendering and substrate for two types of mortar. A parametric model based on finite element analysis has been developed to support the experimental work, which allowed ascertaining temperature profile as well as stress and strain distribution in the mortar rendering by changing the macro-flaws rate and mortar rendering properties. As a result, one could define the variables with higher influence and test panel geometry, as well as the boundary conditions to be used in the experimental program. The experimental program has been performed first in pilot scale and then in a definite stage, which required designing and building of equipment for the execution and control of cyclic thermal shock laboratory tests. Furthermore, bond strength tests have been performed on the mortar rendering samples, and effects of variables have been analyzed by using statistical help. Results have shown that the existence of interfacial macro-flaws decreases bond strength values between mortar rendering and substrate, and this scenario worsens under thermal shock. Mortar renderings with higher Youngs modulus (E) are more affected.
|
139 |
Influência do protocolo de secagem dos canais radiculares na resistência de união e selamento apical de obturações com cimentos com silicato de cálcio e com hidróxido de cálcio / Influence of drying protocols in the bond strength and apical sealing of teeth filled with calcium silicate and calcium hydroxide sealersAdrianne Calixto Freire de Paula 01 October 2014 (has links)
O propósito deste estudo foi avaliar a influência de protocolos de secagem do canal na resistência de união (RU) e no selamento apical (SA) de obturações com AH Plus, Sealapex e MTA Fillapex. Cento e cinquenta e seis raízes de caninos superiores foram submetidas à biomecânica com sistema Reciproc (R50) e distribuídas de acordo com o protocolo de secagem (PS): GI- cones de papel; GII- álcool isopropílico 70% + aspiração com pontas NaviTips; GIII- etanol 95% + cones de papel; GIV- EndoVac + cone de papel. Cada grupo foi dividido em subgrupos conforme o cimento obturador: A- AH Plus; B- Sealapex; C- MTA Fillapex. Utilizou-se para todos os espécimes técnica de obturação do cone único. As raízes de cada subgrupo foram destinadas à avaliação do SA (n=8) e RU (n=5), por meio do método de filtração de fluidos (FF) e push-out (PO), respectivamente. Para o PO as raízes foram seccionadas e um slice de cada terço submetido ao teste e à análise do tipo de falha. Os dados foram submetidos aos testes Anova two-way e three-way e Tukey por meio dos software SPSS 15.0 e SigmaStat 3.5 (α=5%). Os resultados da FF mostraram diferença significante entre os cimentos MTA e Sealapex (p<0,05). O SA não sofreu influência dos protocolos. Na RU não houve diferença entre os terços do canal (p>0,05), mas houve entre os cimentos (p<0,05), protocolos (p<0,05) e na interação cimentos/protocolos (p<0,05). O AH Plus (1,39±0,60) apresentou os maiores valores de RU em relação ao Sealapex (0,83±0,33) e MTA (0,76±0,34). Espécimes secos com álcool isopropílico proporcionaram aos cimentos testados maior resistência de união que quando secos com etanol (p=0,005) e EndoVac (p=0,002). Canais secos com etanol não influenciaram os cimentos. O uso de cones de papel, EndoVac e álcool isopropílico e obturação com AH Plus apresentaram os maiores valores RU que os demais cimentos. Concluiu-se que a infiltração ocorrida com o AH Plus foi semelhante a dos demais cimentos. O AH Plus apresentou os maiores valores de RU. No terço cervical houve predominância de falhas coesivas e de mistas nos demais terços. / The purpose of this study was to evaluate the influence of drying protocols in the bond strength (BS) and in the apical sealing (AS) of teeth filled with AH Plus, Sealapex and MTA Fillapex. One hundred and fifty-six roots of maxillary canines were subjected to biomechanical preparation with Reciproc (R50) and hand out according to the drying protocol (DP): GI-paper points; GII-70% isopropyl alcohol + aspiration with NaviTip points; GIII-95% ethanol + paper points; GIV-EndoVac + paper points. Each group was divided into subgroups according the used sealer: A- AH Plus; B- Sealapex; C- Fillapex MTA. The single cone obturation technique was used for all the samples. The roots of each subgroup were intended for the evaluation of the AS (n = 8) and the BS (n = 5) by using the fluid filtration (FF) and the push-out (PO) methods, respectively. Regarding the PO, the roots were sectioned and a single slice from each third was subjected to testing and also analysed for the type of failure. Data was submitted to the Tukey, two-way and the three-way variance analysis (ANOVA) resorting the SPSS 15.0 and the SigmaStat 3.5 (α= 5%) software. The results of the FF revealed a statistical significant difference between the MTA and the Sealapex (p <0.05) sealers. The AS showed no influence of the protocols. When it comes to the BS there was no statistical significant difference between the canal thirds (p> 0.05), but there was between the sealers (p <0.05), the protocols (p <0.05) and in the interaction between the sealers and the protocols (p <0.05). AH Plus (1.39 ± 0.60) revealed the highest BS comparing with Sealapex (0.83 ± 0.33) and MTA (0.76 ± 0.34). The specimens in which the isopropyl alcohol was used, had the highest bond strength results for the sealers, comparing with ethanol (p = 0.005) and EndoVac (p = 0.002). In the canals that ethanol was used, no alteration of the sealer was noticed. The use of paper points, EndoVac and isopropyl alcohol and filling with AH Plus revealed the highest BS values comparing with the other sealers. It was concluded that the infiltration that occurred with AH Plus was similar with the other sealers. AH Plus showed the highest BS. In the cervical third there was preponderance of cohesive failures, and in the other thirds the mixed type of failure.
|
140 |
Influência da delimitação da área adesiva no ensaio mecânico de microcisalhamento / Evaluation of adhesive area delimitation on microshear testAngela Mayumi Shimaoka 26 June 2007 (has links)
Este estudo teve como objetivos avaliar se a delimitação da área adesiva a ser testada no ensaio mecânico de microcisalhamento é capaz de alterar os resultados de resistência de união obtidos; determinar se a delimitação da área adesiva do ensaio mecânico de microcisalhamento pode alterar o ranqueamento dos sistemas adesivos analisados e correlacionar os tipos de fratura encontrados com valores de resistência adesiva obtidos em cada um dos grupos experimentais. As unidades experimentais foram confeccionadas sobre 18 superfícies de dentina obtidas a partir de incisivos bovinos distribuídas aleatoriamente em 3 grupos, segundo o sistema adesivo a ser utilizado (Adper Single Bond 2, Clearfil Se Bond, Clearfil S3 Bond). Desta forma foram compostos 6 grupos experimentais segundo os dois fatores de variação a serem estudados: sistema adesivo e delimitação da área adesiva. Sobre cada superfície dentinária foram confeccionados 4 cilindros em resina composta, sendo 2 com delimitação da área adesiva e 2 sem a delimitação desta área, totalizando n=12. Após 24 horas de armazenamento os espécimes foram submetidos ao ensaio mecânico de microcisalhamento. O teste estatístico ANOVA (p<0,01) e o teste auxiliar de Tukey determinaram que todos os grupos experimentais em que a delimitação da área adesiva foi realizada apresentaram menores valores de resistência adesiva quando comparados aos seus respectivos grupos controle (sem delimitação da área adesiva). Para os grupos em que não foi realizada a delimitação da área não foram observadas diferenças estatisticamente significantes entre os adesivos empregados. Em contrapartida, quando não foi realizada a delimitação, o sistema adesivo Clearfil S3 Bond mostrou maiores valores de resistência adesiva quando comparado aos sistemas Adper Single Bond 2 e Clearfil SE Bond, que por sua vez não se mostraram estatisticamente diferentes entre si. Concluiu-se que a delimitação da área adesiva no ensaio de microcisalhamento alterou os resultados de resistência adesiva obtidos, e que a modificação da metodologia do ensaio mecânico de microcisalhamento foi capaz de alterar o ranqueamento dos sistemas adesivos analisados. / This study had as objectives to evaluate if the delimitation of adhesive area on microshear test is capable to modify the values of shear bond strength; to determine if this delimitation can modify the ranking of the analyzed adhesive systems and to correlate the found types of failure with the values of bond strength in each experimental group. The specimens were confectioned on 18 incisors bovine dentine surfaces randomly distributed into 3 groups, according to adhesive system used (Adper Single Bond 2, Clearfil If Bond, Clearfil S3 Bond). In such a way, 6 experimental groups were designed according to two factors of variation to be studied: adhesive system and delimitation of the adhesive area. Over each dentin surface were confectioned 4 composite resin cylinders, being 2 with delimitation of the adhesive area and 2 without the delimitation of this area, totalizing n=12. After 24 hours of storage the specimens were submitted to microshear test Statistical test ANOVA (p<0,01) and Tukey?s test determined that all the experimental groups where the delimitation of the adhesive area was carried through presented lesser values of shear bond strength when compared with its respective control groups (without delimitation of adhesive area). Groups without area delimitation did not been demonstrate statistical significant differences between adhesives. On the other hand, when such delimitation was not carried through, the adhesive system Clearfil S3 Bond demonstrates greater values of shear bond strength compared to Adper Single 2 Bond and Clearfil SE Bond, which did not showed statistical difference between them. It was concluded that the delimitation of the adhesive area in the microshear test altered the obtained results of adhesive resistance, and that the modification of microshear test methodology was capable to modify the ranking of the analyzed adhesive systems.
|
Page generated in 0.0753 seconds