• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 77
  • 77
  • 38
  • 34
  • 32
  • 20
  • 20
  • 14
  • 14
  • 13
  • 12
  • 11
  • 10
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Fatores relacionados à variação de cor em restaurações totalmente cerâmicas / Factors related to color variation of all ceramic restorations

Perroni, Ana Paula 29 February 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-19T13:44:00Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Fatores relacionados à variação de cor em restaurações totalmente cerâmicas.pdf: 1927603 bytes, checksum: 03579e441d72863d728e93858c2b1bf6 (MD5) / Made available in DSpace on 2017-06-19T13:44:00Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Fatores relacionados à variação de cor em restaurações totalmente cerâmicas.pdf: 1927603 bytes, checksum: 03579e441d72863d728e93858c2b1bf6 (MD5) Previous issue date: 2016-02-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Restaurações cerâmicas associam as propriedades ópticas dos dentes naturais com satisfatórios resultados clínicos a longo prazo. No entanto, a aparência estética final é influenciada por diversos fatores, tais como a cor e a espessura da cerâmica, o agente de cimentação e a cor do substrato dental, os quais atuam sinérgicamente no resultado estético final. Este estudo foi dividido em três artigos envolvendo restaurações totalmente cerâmicas. Inicialmente, um estudo in vitro foi conduzido para avaliar a influência de diferentes cores de resina flow utilizadas como agente de cimentação na cor final de laminados cerâmicos de diferentes opacidades sobre discos que simulavam substratos dentais de alto valor. Posteriormente, foi apresentado um relato de caso clínico no qual o paciente foi tratado com opções restauradoras totalmente cerâmicas. Além disso, um estudo clínico avaliou a influência de fatores relacionados à variação de cor em restaurações cerâmicas, baseado em análise com espectrofotômetro. No estudo in vitro, discos cerâmicos foram combinados à discos de resina flow com diferentes cores (A1, A2, B1, WO - opaco e IL - translúcido). Foram avaliados o parâmetro de translucidez e a alteração de cor (?E*00) de todos os espécimes sobre discos que simulavam substratos dentários (A2 e B1) e calculados através do método CIEDE2000. O caso clínico relatou a confecção de um laminado cerâmico e de uma coroa como opção restauradora para os incisivos centrais superiores que apresentavam restaurações em resina composta insatisfatórias. No estudo clínico, os valores de ?E*00 foram obtidos de onze pacientes que receberam trinta e oito restaurações cerâmicas em dissilicato de lítio. As coordenadas de cor CIEL*a*b* foram avaliadas com espectrofotômetro para restaurações cerâmicas, cor inicial do dente (baseline), após o preparo dental (substrato), e após a cimentação das cerâmicas. A variação de cor e o parâmetro de translucidez foram calculadas através do método CIEDE2000. O estudo in vitro demonstrou que a opacidade da cerâmica associada com as diferentes cores de agente de cimentação afetou o resultado de cor final dos laminados sobre diferentes substratos. O caso clínico demonstrou que as restaurações cerâmicas restabeleceram a condição estética do paciente. O estudo clínico indicou que a reprodução da cor de dentes naturais é um processo complexo, uma vez que todas as condições avaliadas apresentaram diferenças clinicamente visíveis para as cerâmicas cimentadas. A cerâmica de dissilicato de lítio apresentou menor capacidade de mascaramento sobre substratos escurecidos, enquanto as coordenadas L*, a*, e b* foram influenciadas pela cimentação. / Ceramic restorations associate the optical properties of natural teeth with adequate long-term clinical outcomes. However, the final esthetic appearance is affected by several factors, such as the color and thickness of the ceramic, the luting agent and the dental substrate, which act synergistically on the final esthetic result. This study was divided into three papers involving all ceramc restotations. At first, an in vitro study was conducted to evaluate the influence of different shades of flowable resin composite used as luting agent on the final shade of porcelain veneers of different opacities over high value simulated dental substrates. Afterward, it was conducted a clinical report in which the patient was treated with two different indications of all ceramic restoration. Further, the clinical study evaluated the influence of color-related factors on the color variation of ceramic restorations based on spectrophotometric analysis. In the in vitro study porcelain discs were paired with flowable resin composite disks of different shades (A1, A2, B1, WO – white opaque or IL – translucent). The translucency parameters and color variation (?E*00) of all specimens were evaluated over the simulated dental substrates (A2 and B1) and calculated by CIEDE2000 methods. The clinical report described the confection of a laminate veneer and a fixed single crown to restore superior central incisors that showed unsatisfactory resin composite restorations. In the clinical study, the ?E*00 values were obtained from eleven patients who received thirty-eight lithium disilicate ceramic restorations. The CIEL*a*b* color coordinates were measured with a spectrophotometer for ceramic restorations, initial tooth shade (baseline), prepared tooth (background), and luted ceramics. Color variation and translucency parameters were calculated by CIEDE2000 method. The in vitro study showed that opacity of the porcelain veneer paired with luting agents of different shades affected the final appearance of the restorations over distinct simulated tooth substrates. The case report showed that the ceramic restorations reestablished the esthetic condition of the patient. The clinical study indicated that natural tooth color reproduction is a complex process since all conditions evaluated presented clinically visible color differences for luted ceramic. The lithium disilicate ceramic showed lower masking ability over darker background, while L*, a*, and b* coordinates were cementation dependent.
42

Influência do tipo de material e protocolo restaurador no desempenho físicomecânico de restaurações endocrown / Influence of the restorative material and restorative protocol on the physic-mechanical performance of endocrown restorations

Porto, José Augusto Sedrez 26 May 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-12T13:05:29Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do tipo de material e protocolo restaurador no desempenho físicomecânico.pdf: 8732440 bytes, checksum: ca33e1d6e9f2122117f72f01bfe0db8c (MD5) / Made available in DSpace on 2017-07-12T13:05:29Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do tipo de material e protocolo restaurador no desempenho físicomecânico.pdf: 8732440 bytes, checksum: ca33e1d6e9f2122117f72f01bfe0db8c (MD5) Previous issue date: 2017-05-26 / Sem bolsa / O objetivo deste trabalho foi verificar a influência do tipo de material restaurador (resina composta convencional ou de preenchimento único/bulk-fill) e da técnica restauradora (aplicação ou não de líquido modelador entre camadas de resina composta e utilização ou não de pinos de fibra de vidro para aumentar a retenção do material restaurador) no desempenho físico-mecânico de restaurações do tipo endocrown. O trabalho foi dividido em quatro estudos: (1) uma revisão sistemática e meta-análise da literatura com o objetivo de averiguar se a posição dentária e o tipo da técnica restauradora (endocrown ou com pino de fibra de vidro) influenciariam na resistência à fratura das restaurações; (2 e 3) estudos in vitro que avaliaram se a presença de um material resinoso fluido (líquido modelador) entre as camadas de resina composta melhorariam o desempenho físico-mecânico e estabilidade de cor/translucidez de restaurações de resina composta; e (4) um estudo in vitro que determinou a resistência à fadiga e à fratura de restaurações endocrown, avaliandose a influência do tipo da técnica restauradora (direta ou indireta) e dos sistemas restauradores utilizados. O primeiro estudo foi descrito de acordo com o PRISMA buscando responder se há diferença na resistência à fratura de dentes restaurados com endocrown e pino de fibra de vidro. O segundo e terceiro estudos envolveram metodologias de caracterização físico-mecânica e ópticas dos grupos experimentais. Já o quarto estudo simulou o desempenho de restaurações endocrown em cerâmica, resina composta de preenchimento único ou convencional, contendo ou não líquido modelador; ainda, as restaurações foram confeccionadas usando-se técnica direta ou indireta, e posteriormente submetidas à fadiga mecânica. Para análise estatística dos dados quantitativos, foi utilizado um nível de significância de 5%. Os resultados da meta-análise mostraram que as endocrowns apresentaram resistência à fratura semelhante as restaurações com resina composta. Os resultados dos estudos in vitro indicaram que o líquido modelador (resina adesiva) entre as camadas de resina composta melhorou o desempenho físico-mecânico do material quando comparado à não utilização, sendo mais evidente quando utilizado o adesivo hidrófobo. Com a conclusão deste trabalho, constatou-se que restaurações endocrown podem ser favoravelmente utilizados na rotina clínica para restabelecer a função e estética de dentes tratados endodonticamente e que apresentem grande destruição coronária. Ainda, foi possível compreender o comportamento físico e mecânico de resinas compostas modelados com resinas adesivas (líquido modelador), contribuindo asism para a seleção do melhor sistema restaurador e técnica restauradora para a confecção de restaurações do tipo endocrown. / The aim of this study was to investigate the influence of the type of restorative material (conventional resin composite or bulk-fill) and of the restorative technique (application or not of modeler liquid in-between the layers of resin composite, or the use or not of fiber-reinforced glass posts to increase the retention of the restorative material) on the physic-mechanical performance of endocrown restorations. The work was divided in four studies: (1) a systematic review and meta-analysis of literature aiming to investigate whether the dental position and the type of restorative technique (endocrown or with fiber-reinforced glass posts) would influence the fracture resistance of the restorations; (2 and 3) in vitro studies that evaluated whether the presence of a fluid resin material (modeler liquid) in between the layers of resin composite would improve the physic-mechanical performance and color/translucency stability of resin composite restorations; and (4) an in vitro study that evaluated the fatigue and fracture resistance of endocrown restorations, evaluating the influence of the type of restorative technique (direct or indirect) and of the restorative materials used. The first study was described according to the PRISMA Statement in order to verify the existence of differences concerning the fracture strength of teeth restored with endocrowns or glass fiber posts. The second study used methodologies of physic-mechanical and optical characterization of the experimental groups. Lastly, the fourth study simulated the performance of endocrown restorations prepared with ceramic, resin composites (conventional or bulk-fill) with or without modeler liquid; moreover, the restorations were prepared using direct or indirect techniques, which were submitted to mechanical fatigue testing. For statistical analysis, the data were analyzed with a 5% level of significance. The results of the meta-analysis showed that endocrowns had fracture strength similar to resin composite restorations. The results of the in vitro studies demonstrated that the presence of modeler liquid (resin adhesive) in-between the layers of resin composite improved the physic-mechanical performance of the material, with this effect being more pronounced for the modeler lquid with a hydrophobic composition. In conclusion, endocrown restorations can be satisfactorily used in the daily routine to reestablish the function and aesthetics of severely damaged non-vital teeth. Furthermore, it was possible to understand the physical and mechanical behavior of resin composites modeled using resin adhesives (modeler liquid), thereby contributing for the selection of the best restorative system and restorative technique for preparing endocrown restorations.
43

Resistência à flexão, resistência à tração diametral e dureza de sistemas cerâmicos para infra-estrutura

Schalch, Max von [UNESP] 13 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-13Bitstream added on 2014-06-13T20:58:46Z : No. of bitstreams: 1 schalch_mv_me_arafo.pdf: 500459 bytes, checksum: bbb8a40c8cbaedcfd8d25a115259987e (MD5) / O objetivo deste estudo foi comparar a resistência à flexão, a resistência à tração diametral e a dureza do material de infra-estrutura dos sistemas cerâmicos IPS-Empress 2/Ivoclar (dissilicato de lítio, processado por injeção) e In-Ceram Zirconia/Vita (óxidos de alumínio e zircônio, processados por dupla sinterização). Foram confeccionadas dez amostras de cada material para o ensaio de flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System - EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada cerâmica foram incluídos em resina acrílica autopolimerizável JET (Artigos Odontológicos Clássico, Brasil), polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Os resultados mostraram maior resistência à flexão do material In-Ceram Zirconia (439,88MPa) em relação ao IPS-Empress 2 (226,13MPa). Entretanto, observou-se maior resistência à tração diametral do IPS-Empress 2 (175,08MPa) em relação ao In-Ceram Zirconia (150,47MPa). Para a dureza Vickers, o material In-Ceram Zirconia (972,0VHN) mostrou-se superior em relação ao IPS-Empress 2 (488,33VHN). / The aim of this study was to compare flexural strength, diametral tensile strength and hardness of infra-structure ceramic systems IPS-Empress 2/Ivoclar (litium dissilicate, heat-pressed) and In-Ceram Zirconia/Vita (aluminum and zirconium oxides, Slip casting). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter; 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. In flexural test, In-Ceram Zirconia (439.88MPa) showed greater strength than IPS-Empress 2 (226.13MPa). However, the IPS-Empress 2 (175.08MPa) showed greater diametral strength than In-Ceram Zirconia (150.47MPa). For hardness, the In-Ceram Zirconia (972.0VHN) showed greater than IPS-Empress 2 (488.33VHN).
44

Adesão de um cimento resinoso a uma cerâmica feldspática: avaliação da resistência adesiva, ângulo de contato e ph, em função de diferentes técnicas de condicionamento

Amaral, Regina [UNESP] 26 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-26Bitstream added on 2014-06-13T18:58:09Z : No. of bitstreams: 1 amaral_r_me_sjc.pdf: 3501879 bytes, checksum: f350dffbc6a2244de5a8f806e30513e5 (MD5) / O objetivo deste trabalho foi avaliar a durabilidade da resistência adesiva entre um cimento resinoso e uma cerâmica feldspática, o pH e o ângulo de contato da superfície cerâmica, submetida à diferentes tratamentos de superfície. Para análise do pH de superfície foram confeccionados 96 discos (8X3mm) da cerâmica feldspática (Vita VM7), os quais, foram divididos em 12 grupos (n=8): CS1- sem condicionamento; CS2- ácido fluorídrico (HF) 9% 1 min; CS3- CS2+lava/seca; CS4- CS3+silano (S); CS5- HF 4% 1 min; CS6- CS5+lava/seca; CS7- CS6+silano; CS8- HF 5% 1 min; CS9- CS8+lava/seca; CS10- CS9+silano 20 5min; CS11- CS9+neutralização+lava/seca+ultra-som; CS12- CS11+siano. Após, o pH foi medido com um peagâmetro digital. Para a análise do ângulo de contato foram confeccionados 40 discos com as mesmas dimensões (n=8): CS1- sem condicionamento; CS2- HF 9%; CS3- HF 4%; CS4- HF 5%; CS5- HF 5%+neutralização+lava/seca+ultra-som. As medidas foram realizadas com um Goniômetro. Para a resistência de união, foram confeccionados 40 blocos (6,4X6,4X4,8mm), os quais foram submetidos aos tratamentos (n=10): CS1- HF 9% 1 min; CS2- HF 4% 1 min; CS4- HF 5% 1 min; CS5- CS3+neutralização+lava/seca+ultra-som. Os espécimes foram armazenados em água destilada (37°C) por 24h e seccionados nos sentidos x e y. Os corpos-deprova obtidos foram divididos em 2 condições (Seco- ensaio imediato; TCarmazenagem + termociclagem) e submetidos ao teste de microtração. Na análise do pH, CS6 obteve o maior resultado e CS5, CS8 e CS2, obtiveram os menores valores estatisticamente. Para o ângulo de contato, CS1 obteve médias maiores comparados aos outros grupos. Para resistência de união, CS2=CS1>CS3=CS4, independente do fator armazenagem. Somente o CS4 sofreu redução na resistência adesiva após TC. Conclui-se que a neutralização parece afetar negativamente a resistência adesiva... / The aim of this study was to evaluate the tensile bond strength of a resin-based cement to a feldspathic ceramic (Vita VM7), the pH and the contact angle on a ceramic surface, after submitted to surface conditioning methods. To analyze the pH of the ceramic surface, ninety six disks (8x3mm) of VM7 were fabricated and divided into 12 groups (n=8) according to each treatment condition (CS): CS1- without surface conditioning; CS2- hidrofluoridric acid (HF) 9% 1 min; CS3- CS2+wash/dry; CS4- CS3+silane (S); CS5- AHF 4% 1 min; CS6- CS5+wash/dry; CS7- CS6+silane; CS8- HF 5% 1 min; CS9- CS8+wash/dry; CS10- CS9+silane 5min; CS11- CS9+neutralizer+wash/dry+ ultrasonic cleaning; CS12- CS11+silane. Then, pH was measure using a digital peagameter. Another forty disks (8X3mm) were fabricated and divided into 5 groups to analyze the contact angle: CS1-without conditioning; CS2- HF 9%; CS3- HF 4%; CS4- HF 5%; CS5- HF 5%+ neutralizer +wash/dry+ultra-som, all groups were analyzed by means of a Goniômetro. Forty blocks (6,4x6,4x4,8mm) were fabricated, divided into 5 groups (n=10) and submitted to surface treatments to evaluate the bond strength: CS1- HF 9% 1 min; CS2- HF 4% 1 min; CS4- HF 5% 1 min; CS5- CS3+ neutralizer +wash/dry+ ultrasonic cleaning. The specimens were storage in distilled water at 37°C for 24 hours and cut into to axes (x and y), then the bar specimens obtained were submitted to 2 conditions (Dry - immediate test; TC - storage + thermocycling) and to the microtensile bond strength test. pH values were significantly high for CS6 compared to that of CS5, CS8 and CS2. CS1 had the highest contact angle. In the microtensile bond strength, CS2=CS1>CS3=CS4, independently from the storage condition. CS4 had the lowest microtensile bond strength value after TC. The neutralization decrease the bond strength significantly, which was evidenced by the high contact angles after the surface neutralization.
45

Efeito do sistema de acabamento e polimento na rugosidade superficial e formação in situ de biofilme dentário inicial em cerâmica feldspática micro-particulada

Brentel, Aline Scalone [UNESP] 10 October 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-10Bitstream added on 2014-06-13T18:35:09Z : No. of bitstreams: 1 brentel_as_me_sjc.pdf: 699454 bytes, checksum: be2fb21f3ef054302d8fc5241d84a0a5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente estudo foi avaliar uma cerâmica feldspática micro-particulada quanto à rugosidade superficial, hidrofobicidade e formação in situ do biofilme dentário. Amostras padronizadas da cerâmica foram confeccionadas e divididas em 4 grupos conforme o sistema de acabamento e polimento: glaze (G1); glaze e broca diamantada (G2); glaze, broca diamantada e pontas de borracha (G3); glaze, broca diamantada, ponta de borracha e disco de feltro impregnado com pasta diamantada (G4). Rugosidade foi avaliada antes e após os procedimentos de acabamento e polimento estabelecidos para cada grupo. O ângulo de contato da água deionizada foi avaliado em goniômetro. Dez pacientes usaram dispositivo bucal com amostras dos diferentes grupos durante 8 h. Decorrido o período experimental, o biofilme (n=10) foi analisado em microscopia confocal laser ( biovolume e espessura média) e microscopia eletrônica de varredura (MEV) (n=5). A rugosidade superficial foi significativamente diferente nos 4 grupos, sendo a ordem crescente de rugosidade G1 < G4 < G3 < G2. Em relação ao ângulo de contato, G1 apresentou a maior hidrofobicidade, não havendo diferenças entre os demais grupos. G1 e G4 foram semelhantes e apresentaram os menores valores de espessura média e biovolume do biofilme. G2 e G3 apresentaram os maiores valores de espessura média e biovolume sendo similares. Correlação positiva foi verificada entre rugosidade superficial e formação de biofilme in situ. As observações em MEV indicaram cocos isolados e diplococos em G1 com pouco material acelular. Em G2, presença de maior número de bactérias aderidas às amostras foi verificada. Em G3 foi verificado material fibrilar com cocos e bastonetes curtos constituindo colônias na superfície. Em G4, as amostras foram recobertas por material granular com poucos cocos isolados aderindo à superfície. / This study assessed the effect of different systems of finishing and polishing in a ceramic micro-particulate feldspatic, with respect, the surface roughness, hydrophobicity, topography and morphology analysis using SEM and analysis of biofilms, with respect to its thickness and its average biovolume using MCVL. Specimens (5mmX2mm), were distributed into four groups (n = 10) as, finishing and polishing used: G1: glaze; G2 - drill diamantada (KG Sorensen); G3 - diamantada drill and polishing with rubber tip (KG Sorensen); G4 - diamantada drill and polishing with rubber tip followed by pulp diamantada with disc of felt. Rugosidade was evaluated in rugosímetro (Surftest SJ-301, Mitutoyo) before and after applying the glaze. The hydrophobicity was evaluated by a goniometer (Ramé-Hart - DROPimage, Advanced, USA) Ten patients used a device with the samples for 8h, then they were tested in MCVL. Topography and the morphology were evaluated in SEM. The roughness Ra (μm), biovolume and thickness of the biofilm and were analyzed using ANOVA and Tukey. There was no significant difference with respect to the amount of biovolume factor and the average thickness of biofilm between G2 and G3 and between G1 and G4. G1 and G4, were more hydrophobicity, with respect to G2, G3. There are correlated with roughness and formation of biofilms. There is the possibility of hydrophobicity is linked to lower bacterial adherence.
46

Influência da espessura da cerâmica, do tempo de fotopolimerização e do cimento resinoso na resistência de união à microtração de uma cerâmica vítrea cimentada à dentina humana

Barca, Diana Capelli [UNESP] 07 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-07Bitstream added on 2014-06-13T18:35:10Z : No. of bitstreams: 1 barca_dc_me_sjc.pdf: 4808947 bytes, checksum: 238892d410325de1d23eb76694cb9763 (MD5) / Este estudo avaliou a influência da espessura da cerâmica, do tempo e tipo de fotopolimerização do cimento resinoso na resistência da união entre uma cerâmica vítrea e a dentina coronária humana. A hipótese é a de que o tipo e o tempo de fotopolimerização do agente cimentante e a espessura da cerâmica influenciem na resistência de união entre cimento e dentina. Foram selecionados cento e doze dentes molares humanos hígidos que foram incluídos em resina acrílica e tiveram a superfície oclusal cortadas em máquina Labcut, expondo a dentina planificada. Dois grupos foram tiveram a dentina condicionada com ácido fosfórico 37% lavada e aplicado adesivo (Excite, Ivoclar) fotopolimerizando por 20s. No grupo controle (n=16), utilizou-se cimento auto-adesivo. Foram confeccionados cento e doze blocos (6 x 6 mm) de cerâmica feldspática (Vita PM9) com três espessuras: 1, 2 e 3 mm que tiveram a superfície de cimentação tratad a com ácido fluorídrico 10%, lavada, seca e silanizada. Os blocos cerâmicos foram cimentados, de acordo com o grupo experimental: Variolink II (Ivoclar Vivadent); e fotopolimerizados com LED por 40 ou 80 segundos de fotopolimerização ou cimento Multilink II (no grupo controle). Assim, formaram-se sete grupos (n=16). Os espécimes foram armazenados em água destilada (37°C) por 24 horas e seccionados em dois eixos, X e Y, para a obtenção dos espécimes. Cada grupo (N=16) foi subdividido em 2 (n=8) onde um grupo foi termociclado e o outro submetido ao ensaio de microtração 24 horas após a cimentação. Esse palito (cerâmica/dente) foi fixado no dispositivo de microtração Erios, levado à máquina de ensaio universal e testado com velocidade de 1 mm/min. Os valores médios obtidos (MPa) foram à análise de Variáveis ANOVA 3- fatores, teste de Dunnett e ao teste de Tukey (5%). A resistência adesiva foi significantemente influenciada pelos fatores... / This study evaluated the influence of the thickness of the ceramic, time and type of light curing resin cement on bond strength between a ceramic and glass human dentin. The hypothesis is that the type and time of curing luting agent and the thickness of the ceramic bearing on the bond strength between cement and dentin. We selected one hundred and twelve healthy human molar teeth were embedded in acrylic resin and were cut in the occlusal surface Labcut machine, exposing the dentin. Two groups have had to dentin conditioned with 37% phosphoric acid washed applied adhesive (Excite, Ivoclar) light cured for 20s. In the control group (n = 16), we used self-adhesive cement. We made one hundred and twelve blocks (6 x 6 mm) ceramic feldspathic (Vita PM9) with three thicknesses: 1, 2 and 3 mm that had cement surface treated with hydrofluoric acid 10%, washed, dried, and silanized. The ceramic blocks were cemented according to the experimental group: Variolink II (Ivoclar Vivadent) and cured with LED for 40 or 80 seconds of curing cement Multilink or II (control group). Thus, they formed seven groups (N = 16). The specimens were stored in distilled water (37 ° C) for 24 hours and sectioned in two axes, X and Y, to obtain the specimens. Each group (N = 16) was subdivided into two (n = 8) where a group was thermocycled and another test by microtensile 24 hours after cementation. This toothpick (ceramic / tooth) was mounted in microtensile Erios, led to a universal testing machine and tested at a speed of 1 mm / min. The average values (MPa) were the ANOVA analysis of three variables - factors, Dunnett test and Tukey test (5%). The bond strength was significantly influenced by light irradiation time, thickness of the ceramic thermal cycling
47

Avaliação das discrepâncias marginal vertical e interna de coroas totais cerâmicas confeccionadas por um sistema CAD/CAM, variando o término cervical

Souza, Rodrigo Othávio de Assunção e [UNESP] 15 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-15Bitstream added on 2014-06-13T20:37:57Z : No. of bitstreams: 1 souza_roa_me_sjc.pdf: 815502 bytes, checksum: 2c82a3a91698db3c6e94fda59d746792 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a discrepância marginal (DM) e interna (DI) de coroas totais cerâmicas fabricadas pelo sistema CAD/CAM Cerec inLab, frente a três diferentes términos cervicais. A hipótese nula foi que o tipo de término não influencia a DM e DI das coroas. A partir de três troquéis metálicos com distintos términos cervicais, foram fresadas trinta coroas cerâmicas (ProCad/Ivoclar Vivadent) (n=10): CI) chanfro inclinado; CL) chanfro largo e O) ombro arredondado. Para análise da DM, mensurou-se, em 50 pontos, a distância entre a margem externa de cada coroa à margem do término cervical do respectivo troquel metálico. Utilizando a técnica da réplica, avaliou-se a DI de cada coroa em 12 pontos igualmente distribuídos por regiões: término (T), axial (A) e oclusal (Ocl). As mensurações foram realizadas em microscópio óptico (250x). Os dados obtidos ('mü'm) foram submetidos aos testes estatísticos ANOVA e de Tukey (5%). Os resultados demonstraram que grupo O (28,24'mais ou menos'11,42'mü'm) gerou valores de DM significativamente inferiores (p=0,001) aos dos grupos CI (99,92'mais ou menos'18,32'mü'm) e CL (64,71'mais ou menos'25,64'mü'm), os quais diferiram estatisticamente entre si. A análise da DI demonstrou que o grupo CL (183,01'mais ou menos'62,82'müm) apresentou valores inferiores (p=0,0014) aos demais grupos: CI (216,26'mais ou menos'83,23 'mü'm) e O (219,12'mais ou menos'87,24'mü'm), os quais foram semelhantes entre si. Observou-se também que a DI variou entre as regiões mensuradas (p=0,0001). A hipótese nula foi rejeitada. Baseado nos resultados pôde-se concluir que, apesar das diferenças estatísticas observadas entre os grupos, os três términos cervicais geraram coroas com valores de DM e DI aceitáveis clinicamente. / This study evaluated the marginal discrepancy (MD) and internal (ID) of ceramic crowns manufactured by the CAD/CAM system Cerec inLab, varying the finish line. The null hypothesis was that the preparations won't influence the MD and ID of the crowns. From three metallic dies with different finish lines, thirty ceramic crowns (ProCad/Ivoclar Vivadent) were machined (n=10): TC) tilted chamfer; LC) large chamfer and RS) rounded shoulder. For MD analysis, were measured, in 50 points, the distance between each crown extern edge to the edge of the cervical preparation on the respective metallic die. Using the replica technique, it was evaluated the ID of each crown at 12 points equally distributed between the regions: end (E), axial (A) and oclusal (Ocl). The mensurations were done in optical microscope (250x). The data obtained ('mü'm) were submitted to the statistical tests ANOVA and Tukey (5 %). The results demonstrated that the group RS (28,24 'mais ou menos'11,42'mü'm) produced MD values smaller (p=0,001) than the groups TC (99,92'mais ou menos'18,32'mü'm) and LC (64,71'mais ou menos'25,64 'mu'm), which, between them, differed statistically. The analysis of ID demonstrated that the group LC (183,01'mais ou menos'62,82 'mü'm) presented values lower (p=0,0014) than TC (216,26'mais ou menos'83,23'mü'm) and RS (219,12'mais ou menos'87,24 'mü'm), which were similar between them. It was also noticed that ID varied between the measured regions (p=0.0001). The null hypothesis was rejected. It was concluded that, in spite of the statistical differences observed between the groups, the three cervical finish lines produced crowns with MD and ID values clinically acceptance.
48

Influência da aplicação de um adesivo na durabilidade de união entre uma cerâmica feldspática e um cimento resinoso

Passos, Sheila Pestana [UNESP] 22 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-22Bitstream added on 2014-06-13T20:18:40Z : No. of bitstreams: 1 passos_sp_me_sjc.pdf: 480524 bytes, checksum: a11e54e1df514db177ec967eb88a88cb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar o efeito da aplicacao do adesivo e da ciclagem termica / armazenagem na adesao entre um cimento resinoso, de polimerizacao dual, e uma ceramica feldspatica. As hipoteses sao: (1) a aplicacao do adesivo na ceramica condicionada pode aumentar a resistencia adesiva; (2) a armazenagem e a termociclagem podem diminuir a resistencia adesiva. Vinte blocos (6 x 6 x 4 mm) de ceramica feldspatica microparticulada (Vita VM7) foram confeccionados de acordo com as instrucoes do fabricante. A superficie ceramica foi tratada com acido fluoridrico 10% por 60 segundos, lavada com agua, colocada em agua no ultrassom, seca e silanizada (Porcelain Primer, Bisco). Em seguida, o adesivo foi aplicado em dez blocos (Scotchbond Multi-Purpose Plus Adhesive, 3M ESPE) e fotopolimerizado por 20 segundos. Todos os blocos foram reposicionados em moldes de silicone individuais e o cimento resinoso dual (Variolink base + catalizador, Ivoclar Vivadent) foi aplicado sobre a superficie tratada.Os espécimes foram armazenados em água destilada (37°C) por 24 h e seccionados nos eixos x e y, obtendo-se espécimes com aproximadamente 1 mm'POT.2'de área adesiva. Os 12 corpos de prova (cp)obtidos foram divididos aleatoriamente em 2 condições de armazenamento :seco - ensaio imediato;TC - armazenagem (50 dias) + termociclagem (12.000x, 5°C-55°C). Considerando os 2 fatores do estudo (adesivo e armazenagem), foram constituídos 4 grupos(n=50): Gr1 - sem adesivo + seco; Gr2 - com adesivo + seco; Gr3- sem adesivo + TC; Gr4 - com adesivo + TC. O teste de microtração foi realizado numa máquina de ensaio universal(1 mm/min). A aplicação do adesivo afetou significamente... / This study assessed the effect of the adhesive resin application and the aging on the resin cement to feldspathic ceramic. The hypotheses were: (1) the adhesive application on the conditioned ceramic may increase the bond strength; (2) the storage and thermocycling may decrease the bond strength. Twenty blocks (6 x 6 x 4 mm) of feldspathic ceramic (Vita VM7) were produced according to the manufacturer's instructions. One ceramic surface of each block was conditioned with 10% hydrofluoric acid for 60s, washed with water, ultrasonically cleaned into the water, dried, and silanizated (Porcelain Primer, Bisco). Afterwards, only 10 blocks got resin adhesive layer (Scotchbond Multi-Purpose Plus Adhesive, 3M ESPE), which was cured for 20 s. All the blocks were placed in the custom silicone mold and the dual-cured resin cement (Variolink base + catalyst, Ivoclar Vivadent) was applied on the ceramic surface. The specimens were stored in distilled water at 37°C for 24 h and then sectioned in the x and y axis, to produce non-trimmed bar samples with approximately 1 mm'POT.2'of bonding area. The 12 sp obtained from each block were random divided into 2 storage conditions : Dry- microtensile test after cutting; TC -storage (50 days)and thermo-cycling (x12,000, 5°C-55°). Considering the 2 factors of the study (adesive and storage), ...(Complete abstract, click electronic access below)
49

Resistência adesiva ao cisalhamento de brackets cerâmicos monocristalinos : estudo in vitro / Luís Filipe Siu Lon ; orientador, Olilon Guariza Filho

Lon, Luís Filipe Siu January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: f. 35-38 / Introdução: A crescente procura por tratamentos ortodônticos pelos adultos em busca de correção da oclusão e estética, tem aumentado a demanda no uso de rackets cerâmicos. O objetivo deste trabalho foi avaliar, in vitro, a Resistência Adesiva (RA) ao cisa / Abstract: The purpose of this study was to evaluate the Shear Bond Strength (SBS) and the adhesive failure mode of Radiance® (American Orthodontics, Sheboygan, Wisc) and Inspire Ice® (ORMCO, Orange, Calif) monocrystalline ceramic brackets and compare them
50

Estudo de preparos e da forma da infraestrutura na distribuição de tensões em prótese parcial fixa

Yamamoto, Eron Toshio Colauto [UNESP] 06 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-06Bitstream added on 2014-06-13T19:20:23Z : No. of bitstreams: 1 yamamoto_etc_dr_sjc.pdf: 2267197 bytes, checksum: 537fb4ee2e9f4f60f9c4e4cdae9ad336 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi verificar o comportamento de prótese fixa de três elementos confeccionada em Zircônia e dos dentes suportes quando são utilizados diferentes preparos dos dentes suportes e diferentes formas da infra-estrutura. Simulou-se a ausência do segundo pré-molar superior e realizou-se preparos do tipo ocluso-proximal, proximal-ocluso-proximal, preparo para overlay e para coroa total nos dentes suportes. Utilizou-se dois tipos de formato de conector, o convencional e em forma de arco. Os modelos tridimensionais foram realizados em softwares CAD Rhinoceros® e 3D Studio Max®. Os modelos tridimensionais simularam uma secção da maxila na região entre primeiro pré-molar e primeiro molar e foram compostos por osso medular e cortical, ligamento periodontal, dentina e esmalte. Foi realizada análise de elementos finitos, as análises de tensões foram processadas no programa Ansys®. Os resultados foram apresentados por meio de mapas de cores de tensão/deformação, com a distribuição de tensões e valores numéricos. Os diferentes preparos dos dentes suportes não influenciaram na distribuição de tensões nos dentes suportes. O preparo de coroa total foi o único preparo que diminui a tensão sobre a infra-estrutura. O formato do conector foi significativamente diferente. O conector em forma de arco distribui melhor as tensões na infra-estrutura do que o conector convencional / The aim of this study was to investigate the behavior of three elements fixed partial denture made of three elements made of Zirconia and support teeth when use different preparations of the support teeth and different forms of framework. Simulated the absence of the superior second premolar and the support teeth preparation was occlusal-proximal, proximal-occlusal-proximal, overlay preparation and full crown. We used two types of connector format, the conventional and arc-shaped. The three-dimensional models were made in Rhinoceros CAD software and 3D Studio Max. The model was composed with maxillary first premolar and first molar, cortical and medullary bone, periodontal ligament, dentin and enamel. Analyses of stresses were processed in the program ANSYS ®. The results were presented in color maps of stress / strain, with the stress distribution and numerical values. The different preparations of the support teeth didn´t influence the stress distribution in supppot teeth. The preparation of full crown was the only preparation that reduces the strain on the infrastructure. The shape of the connector was significantly different. The arch-shaped connector was better than conventional connector in the framework stress distribution

Page generated in 0.083 seconds