• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 482
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 1
  • 1
  • 1
  • Tagged with
  • 495
  • 261
  • 62
  • 57
  • 54
  • 48
  • 46
  • 46
  • 46
  • 43
  • 42
  • 42
  • 39
  • 39
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Determinação de íons cádmio e zinco no sistema estuarino - lagunar de Cananéia - Iguape por voltametria de redissolução anódica / Determination of cadmium and zinc ions in the Lagoon - Estuarine System Cananéia - Iguape by anodic stripping voltammetry

Ana Paula Ruas de Souza 15 September 2010 (has links)
A determinação dos íons Cd(II) e Zn(II) foi realizada em amostras de águas estuarinas por voltametria de redissolução anódica utilizando microeletrodo de fibra de carbono (raio =3 µm). O filme de bismuto foi depositado in situ, simultaneamente com os analitos em microeletrodo sob as condições otimizadas. O intervalo linear da curva de calibração para ambos os íons metálicos foi 0,5 -10,0 nmol L-1 e os limites de detecção de Cd(II) e Zn(II) foram estimados em 17 e 52 pmol L-1, respectivamente. A precisão dos resultados fornecidos empregando-se o microeletrodo de filme de bismuto (BiFME) foi avaliada pela realização de experimento com uma amostra certificada e teste de recuperação. A utilidade da metodologia foi demonstrada aplicando o BiFME para determinar baixas concentrações de Cd(II) e de Zn(II) em água do estuário. / A bismuth-film electrode for use in anodic stripping voltammetry was employed in order to quantify Cd(II) and Zn(II) in estuarine water samples. The bismuth film was deposited in situ simultaneously with the analytes onto a carbon fiber disc microelectrode (radius = 3 µm). Under the optimised conditions, calibration plots for both metallic ions were obtained in the range 0.5 to 10.0 nmol L-1 and the limits of detection for Cd(II) and Zn(II) were estimated as 17 and 52 pmol L-1, respectively. The accuracy of the results supplied by the bismuth film microelectrode (BiFME) was assessed by performing experiment with a certified sample and addition-recovery experiments. The usefulness of the methodology was demonstrated by applying the BiFME to measuring the Cd(II) and Zn(II) content in estuarine water.
322

Desenvolvimento e aplicações de eletrodos de ouro confeccionados a partir de discos compactos graváveis (CD-Rs) / Development and applications of gold electrodes confectioned from recordable compact disc (CD-RS)

Eduardo Mathias Richter 22 January 2001 (has links)
O presente trabalho descreve uma forma inédita e simples de construção de eletrodos de ouro (CDtrodos) a partir de discos compactos graváveis (CD-Rs). Os CD-Rs possuem em sua constituição uma película de ouro com uma espessura entre 50 e 100 nm e com área aproximada de 100 cm2. Esta superfície de ouro pode ser facilmente utilizada para construção de eletrodos convencionais usados em células estacionárias ou em células em fluxo. Além disso, a espessura nanométrica do filme de ouro também pode ser utilizada para construção de microeletrodos de banda com áreas inferiores a 10-6 cm2. Devido ao fato do CD-R ser produzido em escala comercial, o custo do mesmo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Para comprovar a viabilidade da utilização destes filmes na confecção de eletrodos, seu desempenho foi comparado com o de eletrodo de ouro comercial, sendo observado um comportamento análogo. Diferentes maneiras de utilização do disco compacto gravável foram testadas, tanto em amostras sintéticas, como também, em amostras reais. Utilizando o método de redissolução potenciométrica à corrente constante (CCPSA), foram analisadas amostras de mercúrio em água potável e em água do mar, adaptando o CD-R a uma célula de injeção em fluxo. Nestes estudos, o limite de detecção de mercúrio situou-se em 250 ng L-1, utilizando-se tempo de deposição de 300 segundos. Estudos preliminares em células estacionárias levaram a limites de detecção inferiores. Em célula estacionária, foram realizadas análises de cobre em aguardente e em água potável. Em alguns casos, os resultados obtidos com as amostras reais foram comparados com outra técnica (E.A.A.), onde os resultados obtidos foram muito próximos a àqueles obtidos com os eletrodos de ouro. Análises em água de abastecimento, mostraram que em células estacionárias o limite de detecção para cobre situa-se em 30 ng L-1, para tempos de deposição de 600 segundos. / This work describes an original and novel form of construction of gold electrodes (CDtrodes) from recordable CDs (CD-Rs). The CD-Rs contain in its constitution a fine gold layer with a thickness from 50 to 100 nm and an approx. 100 cm2 of area. This surface can be easily used for construction of conventional electrodes for stationary or flow electrochemical cells. Moreover, the nanometer thickness of the gold film can be employed for the construction of microelectrodes with areas smaller than 10-6 cm2. Due to the fact that CD-Rs are produced on commercial scale, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. To prove the suitability of these films to make gold electrodes, their performance was compared with the response of a commercial electrode, and a similar behavior was observed. Different applications of recordable compact disk were tested either with synthetic or real samples. Using the Constant-Current Potentiometric Stripping Analysis (CCPSA) method, mercury was analyzed in seawater and drinking water samples, fitting the CD-R to flow injection analysis cell. In these studies, the detection limit for mercury was found to be 250 ng L-1, with a deposition time of 300 seconds. Preliminary studies involving stationary cells allowed lower detection limits for mercury to be attained. With a stationary cell, the analyses of copper in sugar cane spirits and drinking water were carried out. In some instances, comparisons were made between this and another analytical technique (namely A.A.S.) where the results were very close with the ones obtained with the gold electrodes. Analysis of drinking water showed that for stationary cells the detection limit for copper is 30 ng L-1, with a deposition time of 600 s.
323

\"Avaliação do método das médias móveis no tratamento de sinais de absorção atômica de cádmio, chumbo e crômio obtidos por atomização eletrotérmica em filamento de tungstênio\" / \"Evaluation of the moving averages in the treatment of cadmium, lead and chromium atomic absorption signals from electrothermal atomization\"

Flavio de Oliveira Leme 20 December 2006 (has links)
Este trabalho teve como objetivo avaliar o uso do método das médias móveis na atomização de cádmio, crômio e chumbo utilizando filamento de tungstênio de 150 W (OSRAM) como atomizador eletrotérmico. Realizou-se um estudo sistemático da influência da altura de observação, da temperatura e taxa de aquecimento na atomização dos analitos e a viabilidade do uso do método das médias móveis no tratamento dos sinais transientes gerados na atomização. O estudo da influência da altura de observação foi realizado posicionado-se o filamento no centro (0 mm), 1 e 2 mm abaixo do feixe de radiação. A influência da temperatura e da taxa de aquecimento foi estudada utilizando temperaturas na etapa de atomização entre 1890 e 2780 °C. O método das médias móveis foi aplicado aos sinais transientes gerados na atomização, com o filamento posicionado no centro (0 mm), 1 e 2 mm e com temperatura de atomização entre 2060 e 2780 °C, utilizando fatores 0, 3, 5, 7 e 9. No estudo da temperatura e da taxa de aquecimento foram aplicadas ddps no software de controle na etapa de atomização entre 4 e 12 V. As soluções usadas no desenvolvimento deste trabalho foram preparadas em meio 0,1 % v/v HNO3. Utilizou-se como gás de proteção a mistura de 90% Ar+10 % H2. Para o cádmio, recomenda-se a utilização da altura de observação de 1 mm, para o chumbo recomenda-se 0 mm e para o crômio a altura recomendada é a de 2 mm. Os estudos comprovaram a dependência dos sinais de absorção atômica em altura de pico com a temperatura e a taxa de aquecimento. O cádmio foi o analito em que a taxa de aquecimento foi a menos crítica para a atomização, enquanto que o crômio foi o mais afetado pela variação da taxa de aquecimento. Não foi observada diferença significativa entre os sinais de cádmio com alturas de observação de 0 e 1 mm. Para o chumbo, a diferença entre os sinais com altura de observação de 0 e 1 mm foi constante em todas as taxas de aquecimento estudadas. A 2 mm a diferença entre os sinais aumentou com o aumento da taxa de aquecimento. Para o crômio, não ocorreu uma diferença significativa entre os sinais nas alturas de 1 e 2 mm com atomização até 2180 °C. Nos três analitos a sensibilidade aumentou com o aumento da taxa de aquecimento. O método das médias móveis permitiu a diminuição da variação dos sinais transientes do branco e do ruído. Para o cádmio, não ocorreu uma melhora no limite de detecção do método com a aplicação das médias móveis em nenhuma condição. Para o chumbo e crômio, ocorreu uma melhora no limite de detecção do método nas alturas de observação de 0 e 1 mm. O limite de detecção instrumental apresentou uma melhora significativa para os três elementos em todas as condições estudadas. / The aim of this paper was to evaluate the use of moving averages of cadmium, chromium and lead transient atomic absorption signals generated by 150 W (OSRAM) tungsten coil electrothermal atomizer. A systematic study dealing with the influence of observation height, temperature and heating rate on atomization was carried through in order to demonstrate the viability of moving averages in the treatment of the transient signals during the atomization step. The influence of observation height was carried out with the tungsten coil in the center (0 mm), at 1 and 2 mm below the radiation beam. The influence of atomization temperature and heating rate were evaluated between 1890 °C (3.3 K.ms-1) and 2780 °C (9,3 K.ms-1). The transient moving averages were obtained by using factors 0, 3, 5, 7 and 9, with the tungsten coil in the center (0 mm), 1 and 2 mm and with atomization between 2060 and 2780 °C. For obtaining different temperatures and heating rates, an appropriate power supply was used by applying 4 to 12 V (40 to 120 W) to the atomizer during atomization and a mixture 90% Ar+10% H2 was used as purge/atomization gas. Blanks and reference solutions were prepared in 0,1% v/v HNO3. Best results for cadmium were obtained at 1 mm. For lead it is recommended 0 mm and for chromium 2 mm. The studies had proven the dependence of peak height absorbance signals with temperature and heating rate. Cadmium was the analyte where the heating rate was to less critical for the atomization, whereas chromium was affected by the variation of the heating rate. Significant differences were not observed between cadmium signals with observation heights of 0 and 1 mm. For lead, the difference between the absorbance signals with observation heights of 0 and 1 mm were constant in all tested heating rates. At 2 mm the difference between signals increased by increasing the heating rates. For chromium, a significant difference was not noticed between peak height absorbance signals at 1 and 2 mm with up to 2180 °C. As expected, sensitivity increased for all three analytes by increasing the heating rate. The moving average is a powerful mathematical treatment for minimizing unpredictable fluctuations of the base line during the chosen time interval for measuring the transient absorbance signals. With the exception of Cd, where no improvements on the method detection limit were noticed, the application of the moving average for the lead and chromium showed 3 to 4 fold improvement in the LDmet at 0 and 1 mm observation heights, respectively. The LDinstr presented a significant improvement (3 to 6 fold) for the three analytes in all studied conditions.
324

Avaliação da influência do polimorfismo Pro198Leu da Glutationa Peroxidase sobre o estresse oxidativo em população exposta ao chumbo / Evaluation of the Glutathione Peroxidase Pro198Leu polymorphism influence on the oxidative stress in population environmentally exposed to lead.

Fabiana Veiga da Silva 10 December 2008 (has links)
A enzima glutationa peroxidase (GPx-1) possui um importante papel na detoxificação de espécies reativas de oxigênio. Neste estudo foi verificada a influência do polimorfismo Pro198Leu da GPx-1 nos níveis de malondialdeído (MDA) e proteínas carboniladas de 84 voluntários expostos ambientalmente ao chumbo (28 homens e 56mulheres; idade: 18 a 60 anos). Os genótipos para o polimorfismo Pro198Leu da GPx-1 foram determinados por PCR seguido por digestão com enzima de restrição. Chumbo no plasma (Pb_P) e chumbo no sangue total (Pb_S) foram determinados por espectrometria de massas com plasma indutivamente acoplado e espectrometria de absorção atômica com forno de grafite, respectivamente. As freqüências alélicas para os alelos T (que codifica o aminoácido prolina) e C (que codifica o aminoácido leucina) da GPx-1 foram 0,73 e 0,27, respectivamente. Os voluntários foram separados em dois grupos, de acordo com a presença ou ausência do alelo que codifica leucina. Não foi encontrada diferença significativa para as concentrações de Pb_P e Pb_S, bem como para os marcadores de estresse oxidativo entre os grupos. Deste modo, os resultados obtidos sugerem que o polimorfismo Pro198Leu da GPx-1 não torna indivíduos ambientalmente expostos ao chumbo, mais suscetíveis aos danos do estresse oxidativo induzidos pelo metal. / Glutathione peroxidase (GPx-1) plays an important role in scavenger reactive oxygen species (ROS). This study was carried out to assess the effects of GPx-1 gene polymorphism (Pro198Leu) on malondialdehyde (MDA) and carbonyl protein ratio in 84 subjects environmentally exposed to lead. Genotypes for the GPx-1 Pro198Leu polymorphism were determined by PCR and restriction fragment length digestion. Lead in plasma (Pb_P) and lead in total blood (Pb_B) were determined by inductively coupled plasma mass spectrometry and by graphite furnace atomic absorption spectrometry, respectively. The allele frequencies for T (which express the proline aminoacid) and C (which express the leucine aminoacid) were 0.73 e 0.27, respectively. The volunteers were divided in two groups, according to the presence or absence of C allele. No significant differences were found in Pb_P and Pb_B, as well as for the other oxidative biomarkers between the groups. Therefore, the obtained results suggest that the GPx-1 Pro198Leu polymorphism do not affect individuals environmentally exposed to lead greater susceptible to oxidative damage induced for this metal.
325

Avaliação dos polimorfismos do Ácido Delta-aminolevulínico desidratase (ALAD) e Glutationa peroxidase (GPx) sobre estresse oxidativo em trabalhadores ocupacionalmente expostos ao chumbo / Evaluation of delta aminolevulinic acid (ALAD) and glutathione peroxidase (GPx) polymorphisms on oxidative stress in workers occupationally exposed to lead

Airton da Cunha Martins Júnior 04 July 2014 (has links)
O chumbo (Pb) é um metal altamente tóxico no qual os sinais de intoxicação variam bastante ao considerar as diferenças interindividuais. Um dos principais mecanismos de toxicidade do Pb ocorre pela inibição da enzima ácido delta aminolevulínico desidratase (ALAD) no sistema hematopoiético. O Pb também desempenha um importante papel no desbalanço do estado redox, pois sabe-se que ele tem o potencial de aumentar a concentração de espécies reativas de oxigênio (EROS) e inibir enzimas antioxidantes, como por exemplo a glutationa peroxidase (GPx). No entanto, poucos estudos avaliaram estes parâmetros em população ocupacionalmente exposta brasileira. Assim, o presente estudo, objetiva estudar a correlação entre as concentrações de Pb no sangue (Pb-S) de trabalhadores de fábricas de bateria e as atividades das enzimas ALAD e GPx associados com os polimorfismos genéticos da ALAD e GPx. Para tal, foram utilizadas 278 amostras de sangue de trabalhadores expostos ao Pb. As determinações de Pb foram realizadas por espectrometria de massas com plasma acoplado indutivamente (ELAN DRCII Perkin- Elmer). As genotipagens dos polimorfismos genéticos da ALAD e da GPx foram realizadas pela Reação em Cadeia da Polimerase (PCR) em tempo real e as atividades das enzimas ALAD e GPx foram determinadas no sangue por espectrofotometria de UV/VIS. A média da concentração de Pb-S foi de 22,8 ± 14,7 ?g/dL. Foram observadas correlações negativas entre Pb-S e atividade da ALAD (rs -0,24 p<0,01) e Pb-S e atividade de GPx (rs -0,27 p<0,05). Também foi verificada correlação negativa entre a porcentagem de inibição da ALAD e a atividade de GPx (rs -0,21 p<0,01). Em relação aos polimorfismos genéticos, não observamos associação entre os genótipos do ALAD (? -0,19 P>0,05) e GPx (genótipo CT: ? -1,37 P>0,05; genótipo TT: ? -8,37 P>0,05) e a concentração de Pb-S. Não foram observadas associações entre o polimorfismo rs1800668 e a atividade de GPx (genótipo CT: ? -0,016 P>0,05; genótipo TT: ? -0,004 P>0,05). No entanto, foi constatada uma associação entre o genótipo ALAD 1-1 do polimorfismo rs1800435 e a atividade da enzima ALAD (? 3,5 P<0,05). Neste sentido, os resultados deste estudo mostram que o genótipo ALAD 1-1 do polimorfismo rs1800435 do gene ALAD está associado a uma maior atividade da enzima ALAD nos indivíduos expostos ao Pb. Além disso, o polimorfismo rs1800668, localizado no gene que codifica a enzima GPx, não modula a atividade desta enzima nos indivíduos expostos ao metal. Ambos os polimorfismos dos genes ALAD e GPx parecem não influenciar nas concentrações de Pb-S na população estudada. / Lead (Pb) is a highly toxic metal which signs of intoxication vary greatly when considering the interindividual differences. One of the main mechanism of toxicity of Pb is due to inhibition of the enzyme acid delta aminolevulinic dehydratase (ALAD) in the hematopoietic system. Pb also plays an important role in the redox state of unbalance, since it is known that it has the potential of increasing the concentrations of reactive oxygen species (ROS) and inhibit antioxidant enzymes such as glutathione peroxidase (GPx). However, few studies have evaluated these parameters in Brazilian population occupationally exposed. Thus, the present study aims to study the correlation between the concentrations of Pb in the blood (B-Pb) of workers of battery factories and the activities of ALAD and GPx enzymes associated with genetic polymorphisms in ALAD and GPx. Then, blood samples of 278 workers exposed to Pb were collected. Pb was measured by Inductively Coupled Plasma-Mass Spectrometry (Perkin-Elmer ELAN DRCII). The genotyping of genetic polymorphisms of ALAD and GPx was performed by Real-Time Polymerase Chain Reaction (PCR) and activity of ALAD and GPx enzymes in the blood was determined by spectrophotometry UV / VIS. The mean concentration of B-Pb was 22.81 ± 14.73 mg / dL. Negative correlation was found between B-Pb and ALAD activity (rs -0.24 p < 0.01) and B-Pb and GPx activity (rs -0.27 p < 0.05). There was also a negative correlation between the percentage of inhibition of ALAD and GPx activity (rs -0.21 p < 0.01). Considering the genetic polymorphisms, no association between ALAD genotypes (? -0.19 P < 0.05) and GPx (CT genotype: ? -1.37 P > 0.05, TT genotype : ? -8.37 P > 0.05 ) and the concentration of B-Pb. No association between rs1800668 polymorphism and GPx activity (CT genotype: ? -0.016 P > 0.05, TT genotype : ? -0.004 P > 0.05). However an association was found between ALAD 1-1 rs1800435 genotype and ALAD enzyme activity (? 3.5 P < 0.05). Accordingly, the results of this study show that the ALAD 1-1 genotype of rs1800435 polymorphism in ALAD gene is associated with increased activity of ALAD enzyme in individuals exposed to Pb. Furthermore the rs1800668 polymorphism located in a gene encoding the enzyme GPx does not modulate the activity of this enzyme in individuals exposed to the metal. Both polymorphisms of ALAD and GPx genes seem to have no influence in the concentrations of B-Pb in the population studied.
326

Anéis de crescimento de árvores de Araucaria columnaris Hook.: caracterização anatômica, densitométrica e aplicação no monitoramento ambiental / Tree rings of Araucaria columnaris Hook: anatomical and densitometrical characterization and environmental monitoring applicability

Jean Gabriel da Silva Medeiros 01 December 2005 (has links)
O presente trabalho tem como objetivos caracterizar os anéis de crescimento de árvores de A. columnaris, quanto a estrutura anatômica microscópica do lenho, a aplicação na determinação da idade, taxa de crescimento e o teor de Pb em uma seqüência de anéis de crescimento previamente datados. Visa, também, verificar o potencial da espécie no monitoramento ambiental, segundo as técnicas de dendroquímica, definida como a mensuração quanti e qualitativa dos micro e macronutrientes e de elementos traço nos anéis de crescimento das árvores, indicando mudanças retrospectivas na sua absorção e translocação. Foram selecionadas árvores de A. columnaris localizadas no “Campus Luiz de Queiroz” da ESALQ/USP, em dois sítios diferentes. O primeiro em área próxima à Avenida Centenário, caracterizado pelo intenso fluxo de veículos e constituindo-se em uma das principais vias de acesso aos bairros da cidade e às estradas estaduais. O segundo sítio localiza-se no interior do Campus da ESALQ, acerca de 150 m do primeiro sítio e em área de baixa pressão antrópica com as árvores consideradas como testemunha. Foram coletadas amostras do lenho das árvores, através de método não destrutível e feita a caracterização anatômica do lenho de acordo com as normas da AIWA e com o auxílio de um sistema de análise de imagens. Aplicou-se a densitometria de raios X para analisar as variações da densidade aparente dos anéis de crescimento das árvores. A taxa de crescimento e a idade das árvores foram determinadas por técnicas de dendrocronologia, permitindo a correspondência exata de cada anel de crescimento com os anos do calendário. Em cada sítio analisou-se com espectrômetro de absorção atômica com forno de grafite o teor de Pb nos anéis de crescimento. Os resultados obtidos com relação à dendroquímica mostraram que os teores de Pb detectados nos anéis de crescimento das árvores de A. columnaris em um período de 30 anos, embora baixos, indicam a sua ocorrência de forma cíclica no ambiente, a taxa de crescimento do tronco das árvores de A. columnaris não foi afetada pela presença de Pb nos anéis de crescimento, a metodologia de análise dos anéis de crescimento e do teor de Pb no lenho das árvores de A. columnaris mostrou-se eficiente no monitoramento ambiental através da dendroquímica. / The present work has the aim to characterize the micro anatomical features of the tree rings of the A. columnaris, determinate the age and the growth rate, analyze the lead concentration in a tree ring sequence previously dated and to verify the applicability of the this specie in the environmental monitoring using the dendrochemistry techniques. It is defined as the quantitative and qualitative measure of the micro and macronutrients and trace elements in the tree rings. It indicates retrospective changes in the uptake and translocation. These were selected trees of A. columnaris located in the “Campus Luiz de Queiroz” of the ESALQ/USP in two different sites. The first is an area near the Centenário Avenue that is characterized by the intense flux of vehicles and been one of the principal rote of access to the districts and state highways. The second site is located inside the Campus of the ESALQ, 150 m far from the first site. That is an area with low anthropogenic pressure. The trees in this site were considered to be testimonies. These were collected tree wood samples through the not destructive method. The anatomical characterizations were done considering the norms of AIWA and with the auxiliary of the images analyze system. The X ray densitometry was used to check the variations in the tree rings density. The growth rate and the age of the trees were determinate by the dendrochronology technique. It permitted an exact correspondence of the tree rings and the years in the calendar. The dated tree rings lead concentration of each site was analyzed with graphite furnace atomic absorption spectrometry. The dendrochemistry results show that the Pb concentrations in the A. columnaris tree rings during the last 30 years were low and with a cyclic pattern, the growth rate was not affected by the tree rings lead concentration, the tree rings and Pb concentration methodology of analyze was adequate to by used in the environmental monitoring.
327

Concentração de chumbo em dentes de crianças com alterações neurológicas / Concentration of lead in teeth of children with neurological disorders

Regina Aparecida Segatto Saiani 20 March 2012 (has links)
Introdução: A exposição ambiental ao chumbo é uma questão séria do ponto de vista de saúde pública, pois quando ocorre nos primeiros meses e anos de vida pode levar a sequelas neurológicas e comportamentais graves. Objetivos: 1- Determinar a concentração de chumbo obtida por meio de microbiópsias de esmalte realizadas in vivo em esmalte de dentes permanentes ou decíduos de pacientes com problemas neurológicos em tratamento ambulatorial no HCFMRP-USP e comparar os resultados em diferentes grupos de acordo com o diagnóstico. 2- Verificar o perfil dos valores de chumbo segundo informações relacionadas à exposição a esse metal dos referidos pacientes. Método: Uma microbiópsia foi realizada in vivo na superfície do esmalte de crianças de 5 a 12 anos, de ambos os gêneros, atendidas sequencialmente, sem conhecimento sobre a doença, em dois ambulatórios da área de Neurologia do HCFMRP-USP. O chumbo foi medido por espectrometria de absorção atômica com forno de grafite, e o fósforo foi medido colorimetricamente para determinarmos a profundidade da microbiópsia. Uma vez que a profundidade da microbiopsia não pode ser prevista, mas é um factor que influencia o resultado e que temos conhecimento que as concentrações de chumbo diminuem a partir da superfície para o interior do esmalte uma fórmula matemática foi utilizada para calcular a quantidade de chumbo que seria teoricamente encontrada em cada dente à mesma profundidade, e à profundidade seleccionada foi a média de todas as profundidades. As mães ou acompanhantes responderam a um questionário sobre fatores de risco de exposição ao chumbo. Os diagnósticos neurológicos foram obtidos por análise dos prontuários, posteriormente às microbiópsias, sendo criados cinco grupos independentes de crianças, com base na queixa principal: 1 - síndrome motora, SM (N=31); 2 - epilepsia, E (N=25); 3 - cefaléia, C (N=13); 4 - dificuldade escolar, DE (N=11); 5 - distúrbio do comportamento, DC (N=32). Resultados: A profundidade média das microbiópsias foi 3,16 m. Nas concentrações de chumbo obtidas não houve distribuição de Gauss, assim os valores de média, valores máximos e mínimos obtidos em cada grupo foram: 1 - 103,0, 395,0; 2,0. 2 - 64,8, 233,0; 4,0. 3 - 140,3, 434,0; 10,0. 4 - 135,8, 366,0; 38,0. 3 - 158,3, 476,0; 1,9. A análise dos valores de chumbo evidenciou que não houve correlação entre a idade das crianças e os valores de chumbo (Pearson r = -0,016; p = 0,86). Não se observou diferença significativa entre os gêneros (t-test p = 0,55) e também entre os dentes decíduos e permanentes (t-test p= 0,11). Quanto aos grupos com diagnósticos neurológicos, comparando os cinco grupos (ANOVA oneway), houve significância com valor de p= 0,004. O pós teste de Tukey evidenciou diferença significativa, sendo menores os valores de chumbo no grupo com epilepsia em relação aos grupos com dificuldade escolar e distúrbio de comportamento. Na análise dos fatores de risco, ocorreu maior número de crianças que brincam com pilhas no grupo cuja queixa principal era cefaléia em relação ao grupo com deficiência motora (p= 0,002). Não houve diferenças significativas, em nível de 5%, quanto aos valores de chumbo entre os casos com respostas positivas (p=0,53) ao questionário, nem entre as negativas (p=0,99) e nem entre ambos, comparando-se cada um dos fatores. O mesmo ocorreu na análise intragrupo para cada um dos cinco grupos de diagnósticos e entre os grupos. Conclusões: No presente estudo, encontramos maiores valores de chumbo no esmalte superficial em grupos de crianças com dificuldade escolar e distúrbio do comportamento em relação àquele com epilepsia; e ainda, o achado de que os fatores ambientais de risco estudados não tiveram relação com as diferenças observadas entre esses grupos suscita indagações e necessidade de aprofundamento em pesquisas sobre os efeitos danosos do chumbo no tecido neural, mesmo quando se trata de uma população que vive em áreas consideradas sem risco ambiental e com valores de chumbo no sangue (quando são medidos, o que não é o caso deste estudo) abaixo do limite de intervenção. / Background: The environmental exposure to lead is a serious issue from the standpoint of public health, because when it occurs in the first months and years of life it can lead to serious neurological and behavioral consequences. Objectives: 1 - To determine the concentration of lead obtained by an micro biopsy in vivo on permanent teeth enamel or deciduous teeth of patients with neurological problems in outpatient treatment in HCFMRP-USP and compare results in different groups according to diagnosis. 2 - To check the profile of the values of lead according to information related to exposure to the metal of these patients. Method: A micro biopsy was performed in vivo on enamel of children 5-12 years of both genders, attended sequentially, without knowledge of the disease in two clinics in the area of Neurology, USP-HCFMRP. Lead was measured by graphite-furnace atomic absorption spectrometry, and phosphorus was measured colorimetrically to determine the depth of the micro biopsy. Since the micro biopsy depth cannot be anticipated, but is a factor that does influence the result, since lead concentrations are known to decrease from the surface to the inner enamel, a mathematical formula was used to calculate how much lead would be theoretically found in each tooth at the same depth, and the depth selected was the mean of all depths obtained. The mothers or caretakers answered a questionnaire on risk factors for lead exposure. The neurological diagnoses were obtained by analyzing the charts, then the micro biopsy, and created five independent groups of children based on chief complaint: 1 - motor impairment, MI (N = 31), 2 - epilepsy, E (N = 25), 3 - headache, H (N = 13), 4 - school difficulties, SD (N = 11), 5 - behavioral disorder, BD (N = 32). Results: The mean micro biopsy depth of all tests was 3.16 m. The lead concentrations obtained did not follow Gaussian distribution, and median, maximal and minimum values for each group are as follows: 1 - 103,0, 395,0; 2,0. 2 - 64,8, 233,0; 4,0. 3 - 140,3, 434,0; 10,0. 4 - 135,8, 366,0; 38,0. 3 - 158,3, 476,0; 1,9. The analysis of lead values showed no correlation between the age of the children and the values of lead (Pearson r = -0.016, p = 0.86). There was no significant difference between genders (t-test p = 0.55) and also between the primary and permanent teeth (t-test p = 0.11). As for the groups with neurological disorders, comparing the five groups (one-way ANOVA) showed significant p-value = 0.004. The post Tukey test showed significant differences, with smaller values of lead in the group with epilepsy compared to those with school difficulties and behavior disorders. In the analysis of risk factors, a greater number of children playing with piles in the group whose main complaint was headache in the group with motor disabilities (p = 0.002). There were no significant differences in the 5% level, about the values of lead among the cases with positive responses (p = 0.53) to the questionnaire or between the negative (p = 0.99) nor between the two, comparing each of the factors. The same is true for the intragroup each of the five diagnostic groups and between groups. Conclusions: In the present study, we found higher values of lead in the enamel surface in groups of children with school difficulties and behavioral disturbances in relation to that with epilepsy, and also the finding that environmental risk factors studied were not associated with the differences observed between these groups raises questions and need for further research on the harmful effects of lead on neural tissue, even when the population leaves in an environment with no known contamination with lead and shows blood lead concentrations (which is not the case of this study) that are lower than the values considered harmful to health.
328

\"Um estudo sobre o desequilíbrio radioativo da série do urânio em amostras de solo\" / A study on radioactive disequilibrium of the uranium series in soil samples.

Danillo Silva de Oliveira 21 June 2006 (has links)
As atividades específicas do 238U, 226Ra, 210Pb, 232Th e 40K, foram medidas, utilizando-se a técnica de espectrometria gama de alta resolução, em amostras de solo coletadas em três furos com 2,10 m de profundidade e feitos com trado manual. O material amostrado é um latossolo desenvolvido sobre rochas quartzo-feldspáticas. O local da amostragem, no terreno do Instituto de Botânica da Secretaria do Meio Ambiente do Estado de São Paulo, possui uma cobertura vegetal densa que, junto com a camada superficial de solo, não é perturbada desde, pelo menos, 1938. Os 0,60 m superior da camada de solo amostrada correspondem aos horizontes O e A, enquanto que os 1,50 m restantes correspondem ao horizonte B. As medidas de atividade específica do 210Pb foram corrigidas para compensar os efeitos da absorção da radiação gama com 46,5 keV pela matriz de solo. O procedimento de correção baseado na literatura disponível, foi adaptado com o desenvolvimento de equações apropriadas para representar a geometria de detecção em que as medidas foram realizadas. Os resultados mostram que as atividades específicas do 238U e do 226Ra variam pouco em função da profundidade. O perfil de atividades do 238U parece refletir a distribuição dos minerais de argila no perfil de solo, enquanto que o perfil de atividades do 226Ra apresenta um valor praticamente constante em todo o solo analisado. O perfil de atividades do 210Pb mostra um leve enriquecimento desse isótopo nos horizontes O e A em relação ao restante do perfil. Com a exceção dos horizontes mais superficiais, o 226Ra está em desequilíbrio radioativo com o 238U e o solo apresenta razões de atividade 226Ra/238U da ordem de 0,90. O 210Pb está em desequilíbrio radioativo com o 226Ra sendo que as razões de atividade 210Pb/226Ra variam em torno de 0,7 na maior parte do perfil. A atividade específica do 210Pb é inferior à atividade específica do 226Ra em valores que variam de 8 Bq/kg a 18 Bq/kg. A série do 232Th está em equilíbrio radioativo secular em todas as amostras analisadas. As atividades específicas mais baixas do 232Th são observadas nos horizontes O e A. O horizonte B é enriquecido em 232Th o que reflete a maior concentração de argilas nesse horizonte. O 40K está distribuído de forma irregular ao longo do perfil de solo analisado e apresenta atividades específicas variando desde valores abaixo do limite de detecção do laboratório até 37,8 Bq/kg. / The specific activities of 238U , 226Ra, 210Pb, 232Th and 40K were measured, and the 226Ra/238U and 210Pb/226Ra activity ratios were calculated for samples collected in a 2.10 m deep soil profile in a preserved area of the São Paulo Botanic Garden. The sampling site is covered by dense vegetation that, together with the upper soil layer, has not been disturbed since, al least, 1938. The upper 0.60 m of the soil profile corresponds to the O and A soil horizons, whereas the remaining 1.50 m of the profile corresponds to the B horizon. The 210Pb specific activity measurements were corrected for the attenuation of the 46.5 keV gamma radiation by the soil mineral matrix. The attenuation correction procedure is based on the available literature and was adapted to represent the detection geometry of the measurements. The results show that the uranium series is in radioactive disequilibrium in most of the sampled soil. The 226Ra/238U activity ratios vary around 0.9 whereas the 210Pb/226Ra activity ratios resulted in a mean value of 0.7. The unsupported 210Pb specific activities are between -8 Bq/kg and -18 Bq/kg. The 232Th series is in secular radioactive equilibrium in the whole sampled soil layer. The 232Th specific activity distribution seems to reflect the concentration of clay minerals in the soil horizon B. The 40K radionuclide is irregulary distributed in the whole sampled soil layer and it?s specific activities varying from below detection limit to about 37.8 Bq/kg.
329

Efeitos do chumbo na formação do esmalte fluorótico em ratos / Effects of lead in the formation of fluorotic enamel in rats

Giselle de Angelo Souza Leite 18 September 2009 (has links)
A co-exposição ao chumbo e ao flúor pode alterar o grau de fluorose dental, uma vez que ambos se depositam nos tecidos dentais. Ratos Wistar foram separados em 4 grupos: controle e 3 grupos que recebiam água contendo 100ppm de flúor (F), 30ppm de chumbo (Pb), ou 100ppm de F mais 30ppm de Pb desde a gestação. Análise do esmalte e determinação das dosagens de F no esmalte, dentina e osso foram realizadas nos animais com 81 dias. Defeitos nos incisivos dos ratos foram usados como escores em um índice que discriminou lesões na superfície como bandas, ilhas e cavidades. Não houve diferenças nas concentrações de F nos tecidos calcificados entre os grupos F e F+Pb. Os grupos controle e chumbo apresentaram esmalte normal. O grupo F+Pb apresentou defeitos de esmalte mais severos quando comparados com o grupo F (P<0.001). Este estudo mostrou que o Pb exacerbou a fluorose dental em roedores, sugerindo que a co-exposição ao PB pode explicar as diferenças na prevalência de fluorose. / Co-exposure to lead and fluoride may alter the degree of dental fluorosis, since both accumulate in calcified tissues. Wistar rats were allocated in four groups: control, and 3 groups that received water containing 100 ppm of fluoride (F), 30 ppm of lead (Pb), or 100 ppm of F and 30 ppm of Pb (F+Pb) since gestational age. Enamel analysis and F determinations in enamel, dentine, and bone were performed in 81-day-old animals. Incisor defects were scored using an index that discriminated surface lesions as bands, islets, and pits. There were no differences in the F concentration in calcified tissues between the F and F+Pb groups. The control and the Pb groups presented normal enamel. The F+Pb group presented more severe enamel defects compared with the F group (P<0.001). This study shows that Pb exacerbates dental fluorosis in rodents, suggesting that co-exposure to Pb may explain differences in fluorosis prevalence.
330

Desenvolvimento de transistor de efeito de campo sensível a íon (ISFET) para detecção de chumbo / Developing of ion sensitve field effect transistor to lead detection

César, Rodrigo Reigota, 1989- 26 August 2018 (has links)
Orientadores: Jacobus Willibordus Swart, Angélica Denardi de Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T06:34:57Z (GMT). No. of bitstreams: 1 Cesar_RodrigoReigota_M.pdf: 3932101 bytes, checksum: b4dd2542176f2f405f73883dd504a69a (MD5) Previous issue date: 2014 / Resumo: Com a escassez de água potável e com a sua contaminação frequente, a monitoração da mesma tornou-se importante. Dentre os muitos contaminantes, temos o chumbo (Pb). Este no passado foi muito utilizado em encanamentos residenciais, causando a contaminação da água. O chumbo pode causar danos á saúde humana desencadeando desde disfunções nos rins, aborto até alguns tipos de câncer. Dessa forma a criação de um dispositivo do tipo ISFET (Transistor de Efeito de Campo Sensível a Íon), que detecta a presença de cátions e ânions em água, está sendo desenvolvido para a detecção específica do chumbo. Para tal fim, foram utilizados filmes finos de óxido de titânio (TiO2) como dielétrico de porta e foi utilizado fosfato de cério fibroso (CeP) como membrana seletiva (material desenvolvidos no Laboratório de Química do Estado Solido - LQES[1]). Os filmes finos de TiO2 foram obtidos por dois métodos: i) deposição de titânio metálico por sputtering seguido pelo processo de oxidação térmica rápida (rapid thermal process - RTP); ii) deposição do óxido de titânio por sputtering. Foi escolhido o dióxido de titânio (TiO2) devido as suas características como: alta constante dielétrica, capacidade de formar pontes de hidrogênio e estabilidade química. Os filmes de TiO2, foram caracterizados estruturalmente por espectroscopia Raman; apresentando picos relacionados à estrutura cristalina rutilo, o que foi através do índice de refração igual a 2.4 encontrado na elipsometria. A microscopia de força atômica (AFM) e microscópio óptico mostraram a uniformidade do filme de CeP, dessa maneira sendo possível determinar qual é o melhor método de deposição da solução de CeP. Para testar qual método de deposição que resultou no melhor filme fino de TiO2, foram desenvolvidos capacitores com estrutura Si/TiO2e Si/SiO2/TiO2 no CCS (Centro de Componentes Semicondutores). Dessa maneira foram realizadas as medidas capacitância por tensão (CxV) e corrente por tensão (IxV) para vários tempos de recozimento. Levando-se em consideração o menor valor de densidade de carga, tensão de banda plana próximo ou igual a -0,9 V e o maior valor da constante dielétrica foi possível determinar que para ambos os métodos de deposição a melhor estrutura é a de Si/TiO2, com 10 minutos de recozimento para o filme obtido por RTP e com 15 minutos para o filme obtido por sputtering. Com a melhor condição elétrica de funcionamento dos capacitores foi desenvolvido o Eletrólito-Isolante-Semicondutor (EIS). A partir da curva CxV dos dispositivos EIS sem a membrana de CeP e com o óxido de Ti obtido por RTP, foi possível determinar a sensibilidade de 45mV/pH para soluções com diferentes valores de pH e sensibilidade igual a 42mV/100ppm para soluções com diferentes concentrações de chumbo. Com a membrana seletiva o dispositivo mostrou sensibilidade de 40mV/100ppm para soluções com concentrações diferentes de chumbo. O dispositivo EIS com óxido obtido por sputtering teve sensibilidade de 96mV/pH na detecção de pH, sendo está sensibilidade maior que a obtida pelo EIS obtido por RTP. Ao testar soluções com diferentes concentrações de chumbo, o dispositivo sem a membrana seletiva mostrou uma sensibilidade de 30mV/100ppm. Neste caso, o EIS com membrana seletiva mostrou uma sensibilidade de 20mV/100ppm / Abstract: With the shortage of drinking water and with their frequent contamination, monitoring the same became important. Among the many contaminants, we have lead (Pb). This in the past it was widely used in residential plumbing, one of the ways that caused water contamination. Lead can cause damage to human health from kidney dysfunction, causing abortion and even some types of cancer. In this way the creation of a device of type ISFET (Sensitive Field Effect Transistor for ion), which detects the presence of cations and anions in water, is being developed for the specific detection of lead. For this purpose, we used thin titanium dioxide (TiO2) films as dielectric and fibrous cerium phosphate (CeP) was used as selective membrane (material developed in the laboratory of Solid State Chemistry-LQES[1]). The TiO2 thin films were obtained by two methods: 1) metallic titanium was deposited by sputtering then was oxidized by rapid thermal oxidation process (RTP); 2) Consist in titanium oxide deposition by sputtering. Titanium dioxide was chosen due to it quality was dielectric constant, ability to form hydrogen bonds and chemical stability. TiO2 thin films were structurally characterized by Raman Spectroscopy showing peaks related to rutile crystal structure, which has been proven through the refractive index equal to 2.4 found on elipsometria. The atomic force microscopy (AFM) and optical microscope showed the uniformity of the CeP film, thus being able to determine what the best method of deposition of CeP solution. To test which method has the best TiO2 thin film capacitors were developed with Si/TiO2 and Si/SiO2/TiO2 structure on CCS (Centre of Semiconductor Components). In this way were carried out the measures capacitance of versus voltage (CxV) and current versus tension (IxV) for various annealing times. Taking into consideration the smallest value of charge density, flat-band voltage near -0.9V and the greatest value of dielectric constant, it was possible to determine that for both methods of deposition the best structure is the Si/TiO2, with 10 minutes of annealing for the film obtained by RTP and with 15 minutes to the film obtained by sputtering. With the best electrical capacitors operating condition was developed the Electrolyte-Insulator-Semiconductor (EIS). From the curves CxV without the membrane of CeP and the titanium oxide obtained by RTP, it was possible to determine the sensitivity of 45mV/pH for pH detection and sensitivity of 42mV/100ppm for lead detection. With the selective membrane the EIS showed a sensitivity of 40mV/100ppm for lead detection. The EIS device with TiO2 obtained by sputtering showed a sensitivity of 96mV/pH for pH detection and sensitivity of 30mV/100ppm for lead detection. The EIS with selective membrane showed a sensitivity of 20mV/100 ppm for lead detection / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica

Page generated in 0.034 seconds