• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 524
  • 32
  • 17
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 589
  • 350
  • 88
  • 80
  • 79
  • 51
  • 47
  • 47
  • 41
  • 40
  • 37
  • 36
  • 34
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
461

Estudo teórico-experimental da transferência de calor e do fluxo crítico durante a ebulição convectiva no interior de microcanais / A theoretical and experimental study on flow boiling heat transfer and critical heat flux in microchannels

Cristiano Bigonha Tibiriçá 13 July 2011 (has links)
A pesquisa realizada tratou do estudo da transferência de calor e do fluxo crítico durante a ebulição convectiva no interior de canais de diâmetro reduzidos a partir de dados levantados em bancadas experimentais construídas para esta finalidade. Extensa pesquisa bibliográfica foi efetuada e os principais métodos disponíveis para previsão de coeficiente de transferência de calor, fluxo crítico e mapas de escoamento foram levantados. Os resultados obtidos foram parametricamente analisados e comparados com os métodos da literatura. Pela primeira vez para microcanais, resultados experimentais foram levantados por um mesmo autor em laboratórios distintos buscando verificar a tendência e comportamentos. Tal comparação tem sua importância destacada em face das elevadas discrepâncias observadas na literatura quando resultados de autores distintos, obtidos em condições similares, são comparados. Os resultados levantados foram utilizados na elaboração de modelos que consideram os padrões de escoamento observados em microcanais. A incorporação dos padrões permitiu o desenvolvimento de modelos mecanísticos para coeficiente de transferência de calor, fluxo crítico e critérios para a caracterização da transição entre macro e microcanais baseados na formação do padrão de escoamento estratificado e na simetria do filme líquido no escoamento anular. / This research comprises an experimental and theoretical study on flow boiling heat transfer and critical heat flux inside small diameter tubes based on data obtained in experimental facilities specially designed for this purpose. A broad literature review was carried out and the main methods to predict the heat transfer coefficient, critical heat flux and flow patterns were pointed out. The experimental results were parametrically analyzed and compared against the predictive methods from literature. For the first time, microchannels experimental results obtained by an unique researcher in distinct laboratories were compared and a reasonable agreement was observed. The importance of such a comparison is high-lighted for flow boiling inside microchannels due to the high discrepancies ob-served when results from independent laboratories obtained under similar experimental conditions are compared. Moreover, the experimental results obtained in the present study were used to develop correlations and models for the heat transfer coefficient and heat flux that takes into account the flow patterns observed in microchannels. The heat transfer coefficient and critical heat flux models were developed based on mechanistic approach. In addition, criteria to characterize macro to microchannel transition were proposed based in the occurrence of the stratified flow pattern and the liquid film symmetry under annular flow conditions.
462

Cálculo da probabilidade de adesão de átomo incidente em superfície metálica. / Computation of the sticking probability of a incident atom on metallic surface.

Makoto Yoshida 11 September 1986 (has links)
Desenvolve-se um novo método de cálculo da probabilidade de adsorção química de átomos incidentes em superfícies metálicas. Introduz-se um modelo teórico de adsorção cujo Hamiltoniano descreve um átomo incidindo normalmente e interagindo com os elétrons da banda de condução de uma superfície metálica. Como interações, são levadas em consideração (1) a possibilidade de transferência de energia cinética e de carga do átomo para o metal e (2) o potencial de carga imagem do átomo ionizado. A solução do modelo consiste em se tratar a parte eletrônica e a nuclear do Hamiltoniano separadamente. A parte eletrônica é tratada com a técnica de grupo de renormalização introduzida por Wilson e a parte nuclear, através da solução numérica da equação de Schrödinger para o movimento nuclear. O acoplamento entre as duas componentes do hamiltoniano é tratado como perturbação à aproximação adiabática. A probabilidade de adsorção é calculada em função da energia cinética do átomo incidente através da regra de ouro de Fermi. Os resultados, mostrando que a probabilidade de adsorção decai rapidamente acima de uma energia cinética característica, são interpretados fisicamente. / A new procedure that calculates sticking coefficients for atomic beams incident upon metallic surfaces is discussed. A model Hamiltonian describing the normal incidence of an ad-atom and its interaction with the conduction electrons of the adsorbate is introduced. The Hamiltonian accounts for two couplings: (1) the overlap between the atomic orbital and the metallic conduction states, allowing charge transfer between incident particle and adsorbate, and (2) the image potential associated with the ionized ad-atom. The electronic and nuclear parts of the model Hamiltonian are diagonalized separately, the former by renormalization group techniques and the second by numerical integration of the Schrödinger equation for the nuclear motion. Through the perturbative treatment, the first order corrections to the adiabatic approximation are presented. The results, showing that the sticking coefficient diminishes rapidly above a characteristic kinetic energy o£ the incident atom, are interpreted.
463

Aplicação do método inverso de condução de calor na avaliação de fluidos de resfriamento para têmpera / Application of the inverse method of heat conduction in the quenchants evaluation to quenching

Guilherme Ernesto Serrat de Oliveira Cremonini 25 June 2014 (has links)
A têmpera dos aços envolve a austenitização de uma peça seguida por um resfriamento rápido para promover a formação de microestrutura martensítica. É necessário avaliar os meios de têmpera para manter o processo de têmpera sob controle. Os parâmetros mais importantes no processo de resfriamento são o coeficiente de transferência de calor e/ou o fluxo de calor entre o meio de têmpera e a peça a ser resfriada. Um dos métodos de se avaliar os meios de têmpera (meios de resfriamento) e saber o que está acontecendo dentro da peça durante o resfriamento do ponto de vista térmico é o problema inverso de condução de calor. O problema inverso de condução de calor consiste na determinação de parâmetros como fluxo de calor, taxa de resfriamento e temperatura em qualquer posição através da peça, assim como o coeficiente de transferência de calor. Esses parâmetros são obtidos a partir de medições de temperatura em um ou mais pontos dentro da peça. O escopo deste trabalho foi desenvolver um software baseado no problema inverso condução de calor para avaliar meios de resfriamento para têmpera. A validação deste código foi feita usando água, óleo de soja, óleo mineral e solução aquosa de NaNO3. / Steels quenching involves part austenitization followed by a fast cooling to promote martensitic microstructure formation. It is necessary to evaluate quenchants in order to keep the quenching process under control. The most important cooling process parameters are the heat transfer coefficient and/or the heat flux between the quenchant and the part to be cooled. One of the methods to evaluate quenchants (cooling media) and to know what is happening inside the part during the cooling in the thermal point of view is the inverse heat conduction problem. The inverse heat conduction problem consists in the determination of parameters like heat flux, cooling rate and temperature in any position across the part, as well as the heat transfer coefficient. These parameters are obtained from temperature measurements in one or more points inside the part. The scope of this work was to develop a software based in the inverse heat conduction problem in order to evaluate quenchants for quenching. The validation of this code was made using water, soybean oil, mineral oil and NaNO3 aqueous solution.
464

Estudo da condensação de refrigerantes halogenados e suas misturas com óleo de lubrificação no interior de micro canais / Condensation study of halogen refrigerants and mixtures with lubricant oil in microchannel tubes

Williams Gonzales Mamani 26 October 2001 (has links)
A presente pesquisa envolve um estudo teórico-experimental da transferência de calor e da perda de carga na condensação e no escoamento monofásico de fluidos refrigerantes halogenados no interior de lâminas com micro canais. Os ensaios consideram o fluido refrigerante puro R-134-a e a mistura quase azeotrópica R-410A. As lâminas estudadas envolvem micro canais de seção quadrada de Dh = 1,214 mm e de seção circular de Dh = 1,494 mm. Os ensaios de líquido subresfriado compreendem velocidades mássicas de 390 a 1360 Kg/sm2 para um temperatura de saturação de 40ºC e subresfriamento de 10ºC. Por sua parte, os ensaios foram realizados considerando um fluxo de calor constante de 5 kW/m2, títulos de vapor de 0,1 a 0,9, velocidades mássicas de 410 a 1135 kg/sm2, temperaturas de saturação de 40 a 50ºC e misturas óleo-refrigerante com concentrações de óleo em massa de 0,25 e 0,45%. Para cada condição de ensaio foram avaliados o coeficiente de transferência de calor e a queda de pressão por atrito na lâmina ensaiada. Os resultados para escoamento monofásico apresentaram consistência com relação às correlações típicas aplicáveis a transferência de calor e perda de carga para regime turbulento em tubos convencionais, apresentando, em média, valores de 12% superiores. Na maioria das condições de ensaios de condensação, segundo mapas de escoamento disponíveis na literatura, foi identificado o domínio do padrão estreitamento anular. Este comportamento foi aferido pelos resultados experimentais de perda de carga mostrando dependência quase exclusiva do parâmetro de Martinelli, e o mecanismo conectivo como principal mecanismo de transferência de calor, característico no padrão anular. Os resultados de condensação foram correlacionados a partir de abordagens empíricas em função do parâmetro de Martinelli e o conceito de velocidade mássica equivalente. Assim como, a partir de uma abordagem semi-empírica considerando um modelo anular que permite avaliar os mecanismos principais de transferência de calor e quantidade de movimento, avaliando a espessura do filme de líquido na parede do canal. Finalmente, os resultados experimentais e os obtidos a partir das correlações desenvolvidas são comparados com estudos disponíveis na literatura relativos a lâminas com micro canais. / This project involves a theoretical-experimental study of heat transfer and pressure drop in condensation and single phase flow of halogen refrigerants in microchannel tubes. The tests include the pure refrigerant R-134a and quasi azeotropic mixture R-410A. The microchannel tubes tested include one with square ports of Dh = 1,214 mm and other with circular port of Dh = 1,494 mm. The subcooled liquid tests considered the mass velocities of 390 to 1360 kg/sm2, the saturation temperature of 40ºC and subcooled of 10ºC. The condensing tests considered a constant heat flux of 5 kW/m2, vapor quality of 0,15 to 0,9, mass velocities of 410 to 1135 kg/sm2, saturation temperature of 40 to 50ºC and oil-refrigerant mixtures with oil mass concentrations of 0,25 and 0,45%. For each test condition was evaluated the coefficient of heat transfer and frictional pressure drop in the microchannel tube. The single phase results agree with typical correlations used in conventional tubes to evaluate the heat transfer and pressure drop in turbulent flow, even though the most of experimental date are 12% higher. The most of flow patterns in condensation were identified as annular using the flow patterns maps available on literature. This behavior was verified through pressure drop results, which show exclusive dependence on Martinelli Parameter. The heat transfer results show that the main heat transfer mechanism was convective, typical in annular flow. The results of condensation were correlated from empirical approachs using the Martinelli parameter and the equivalent mass velocity concept. And, also a semi-empirical approach modeling the annular flow to evaluate the mechanism of heat transfer through the liquid film around the wall of the tube. Finally, the experimental results and the results obtained through the models were compared with correlations referred to microchannels available on the literature.
465

Ultra baixo coeficiente de atrito no deslizamento de  Al2O3 - Si3N4: efeito das variáveis químicas (pH e concentração de sílica coloidal). / Ultra low friction coefficient in sliding of Al2O3-Si3O3: effects of chemical variables (pH and concentration of colloidal silica).

Roberto Pereira de Oliveira 27 February 2012 (has links)
O objetivo deste trabalho, foi investigar o comportamento tribológico do par cerâmico alumina - nitreto de silício no deslizamento em água com pH controlado e em uma suspensão com diferentes concentrações de sílica coloidal em água, e verificar a possibilidade de atingir um coeficiente de atrito da ordem de milésimos (&#956; < 0,01), aqui chamado de ultra baixo coeficiente de atrito (UBCA) e verificar se a mudança do pH do meio, ou a alteração da concentração de sílica na água, diminui o runningin, tempo necessário para o sistema entrar em regime estacionário, do coeficiente de atrito. Os ensaios foram realizados na configuração de ensaio tribológico esfera contra disco, no qual a esfera foi de nitreto de silício e o disco de alumina, sob carga normal de 54 N e velocidade de deslizamento de 1 m/s. A água utilizada nos ensaios foi destilada e deionizada, e a sílica coloidal amorfa, sem porosidade e de tamanho médio de partícula de 12 nanômetros foi a Aerosil® 200. A esfera de nitreto de silício, adquirida comercialmente, e o disco de alumina, foi proveniente de trabalhos anteriores. Todos os materiais foram caracterizados quanto a densidade. Algumas propriedades mecânicas como dureza, módulo de elasticidade e tenacidade à fratura foram determinadas. Nos ensaios lubrificados com água onde o pH foi controlado, o sistema atingiu o regime com valores de coeficiente de atrito da ordem de milésimos, exceto quando o pH da água era muito baixo ou muito alto. Em hidrossol o coeficiente de atrito chegou a unidades de milésimos, mas quando se aumenta a concentração de sílica coloidal, também, aumenta o desgaste nas superfícies. O disco de alumina sempre apresentou menor desgaste do que a esfera de nitreto de silício, em todas as condições estudadas. / The objective of this work was to investigate the tribological behavior of the ceramic pair alumina-silicon nitride, sliding on the water with controlled pH and in a suspension with different concentrations of colloidal silica in water, and verify the possibility of achieving a friction coefficient in the order of thousandths (&#956; < 0.01), here called ultra low friction coefficient (ULFC) and verify if the change of pH or changing the concentration of silica in the water, decreases the running-in, time required for the system reach the steady state of friction coefficient. The tests were conducted in a pin on disc setup in which the ball was made on silicon nitride and the disc of alumina, under normal load of 54 N and a sliding velocity of 1 m/s. The water used in the experiments was distilled and deionized. The amorphous silica, without porosity and average particle size of 12 nanometers was Aerosil ® 200. The ball of silicon nitride, was purchased commercially, and the alumina disk was recycled from previous works, all materials were characterized by density. Some mechanical properties such as hardness, elastic modulus and fracture toughness were determined. In tests with controlled pH water the system has reached the friction coefficient of the order of thousandths, except when the pH of the water was too low or too high. In hydrossol the friction coefficient reached units of thousandths, but when increasing the concentration of colloidal silica also increases the wear in the surfaces. The alumina disc always showed less wear than the ball of silicon nitride, in all conditions studied.
466

Conformação mecânica: efeito da topografia na tansferência de material e no atrito. / Metal forming: the effect of topography on the metal transfer and friction.

Mario Vitor Leite 30 June 2010 (has links)
Com a evolução dos processos de fabricação, aumenta o emprego de topografias engenheiradas com o objetivo de aumentar o desempenho dessas superfícies sob vários aspectos. Apesar do bom desempenho comprovado em algumas aplicações, existem outras em que o desempenho é questionável, como, em condições não lubrificadas e com elevadas pressões de contato. Neste cenário de dúvidas sobre a utilização de superfícies engenheiradas, o presente trabalho objetiva contribuir com as discussões por meio de um estudo do efeito de topografias anisotrópicas na transferência de material e resistência ao movimento em condições de deslizamento a seco com deformação plástica micro e macroscópica. O método utilizado contempla ensaios tribológicos que consistem, basicamente, em deslizar um material sobre superfícies engenheiradas de outro material com maior dureza, em duas condições de deformação plástica: i/ localizada no pico das asperezas em contato (ensaio pino-sobre-disco) e ii/ volumétrica (ensaio de compressão do anel). Os resultados permitiram concluir que os mecanismos de desgaste podem ser reproduzidos nos dois ensaios. Com deformação plástica microscópica (pino-sobre-disco) constatou-se que: i/ os vales e cavidades da topografia atuam de forma a evitar o contato das partículas de desgaste com o corpo em deslizamento; e ii/ os maiores valores do coeficiente de atrito foram obtidos com a superfície com maior quantidade de cavidades, a mesma condição topográfica que apresentou maior área com transferência de material. Com deformações plásticas macroscópicas (ensaio de compressão do anel) constatou-se que os vales da topografia da ferramenta atuaram como bloqueios para o deslizamento do anel conformado, o que resultou num aumento do coeficiente de atrito e redução da transferência de material. / The evolution of manufacturing progresses increases the use of engineered surfaces, seeking the improvement of the overall performance of these surfaces. Despite the enhanced performance under some circumstances, uncertainties still exist in conditions such as unlubricated and high contact pressure conditions. This work aims contributing to these discussions by studding the effect of anisotropic topographies on the material transfer and resistance to movement under dry sliding conditions including micro and macroscopic plastic deformation. The method consisted of tribological tests by sliding a material against engineered surfaces of higher hardness. Tests were conducted under two plastic deformation conditions: i/ localized on surface asperities contact (pin-on-disc test) and ii/ volumetric (ring test). Results allowed concluding that wear mechanisms can be reproduced on both tests. Under microscopic plastic deformation (pin-on-disc test) it was possible to verify that: i/ grooves and cavities have contributed to avoid the contact between wear debris and sliding body; and ii/ the higher friction coefficient was obtained when testing the surface with high amount of cavities, a condition that presented the larger area of material transfer. Under macroscopic deformation (ring test), grooves from tool topography played the role of blocking the ring material sliding, increasing friction coefficient and decreasing material transfer.
467

Modelagem matemática da secagem do feijão caupi e efeito sobre a qualidade fisiológica das sementes.

Camicia, Rafaela Greici da Motta 12 March 2013 (has links)
Made available in DSpace on 2017-07-10T19:23:38Z (GMT). No. of bitstreams: 1 Rafaela.pdf: 1254631 bytes, checksum: 3d834f48484b52c9ceff46d1a42fb49a (MD5) Previous issue date: 2013-03-12 / The cowpea bean, a culture traditionally planted in the Brazilian Northeast, has been expanding to other regions of Brazil, mostly to the Midwest, in the states of Mato Grosso and Mato Grosso do Sul, on account of its wide adaptability to tropical conditions and low production cost. Most of the seeds after harvest do not have appropriate characteristics for the storage, mainly due to high water content at harvest time. Drying is the most widely used process to preserve the quality of the product. The operation consists in removing some water contained in the fresh beans. In this context, the aim of this study was to determine and model the drying curves of cowpea beans at temperatures of 30, 40 and 50 °C, adjusting different mathematical models to experimental data, to select the one that best represents the phenomenon, determine the effective diffusion coefficient, and evaluate the physiological quality of seeds. They were seeds of cowpea bean cultivars BRS Guariba and BRS Novaera, harvested by hand, with water content of 0.21 (bs) and 0.16 (bs) respectively, dried to the level 0.11 (bs). The drying process was carried out in an experimental dryer under controlled temperatures of 30, 40 and 50 ° C and relative humidity of the drying air between 14% and 59%. The drying time for the cowpea bean seeds (BRS Guariba cultivar) was 10.4, 5.6 and 2.1 hours at temperatures of 30, 40 and 50 ° C respectively. For BRS Novaera, the drying lasted 8.7, 4.7 and 2.0 hours at temperatures of 30, 40 and 50 °C respectively. The mathematical model of Midilli was the one that best adapted to the experimental data for both cultivars. The diffusion coefficient increases with the temperature, with values from 5.047 to 12.011 x 10-11 x 10-11 m² s-1, for BRS Guariba, and from 2.482 x 10-11 to 5.187 x 10-11 m² s-1 for BRS Novaera in the temperature range from 30 to 50 °C. The relation between the effective diffusion coefficient and the drying temperature can be described by the Arrhenius equation, which has activation energy of 35.04 kJ.mol-1 and 29.76 kJ.mol-1 for liquid diffusion in the drying process of cowpea bean seeds. After the drying process, the seeds percentage of normal seedlings were more than 87%, and under the different conditions of study they presented low force, since the drying under a temperature of 40 °C was the one which produced the most satisfactory results. / O feijão-caupi, cultura tradicionalmente cultivada no Nordeste brasileiro, vem se expandindo para diversas regiões do Brasil, principalmente para o Centro-Oeste, nos estados do Mato Grosso e Mato Grosso do Sul, em razão da sua ampla adaptabilidade às condições tropicais e ao baixo custo de produção. Após a colheita, a maior parte das sementes possui características inadequadas para o armazenamento, devido principalmente ao alto conteúdo de água na época da colheita. A secagem é o processo mais utilizado para a preservação da qualidade desse produto. A operação consiste na remoção de parte da água contida no feijão recém colhido. Neste contexto, o objetivo deste trabalho foi determinar e modelar as curvas de secagem do feijão-caupi, nas temperaturas de 30, 40 e 50 °C, ajustando-se diferentes modelos matemáticos aos dados experimentais e selecionar aquele que melhor representa o fenômeno, bem como determinar o coeficiente de difusão efetivo e avaliar a qualidade fisiológica das sementes. Foram utilizadas sementes de feijão-caupi das cultivares BRS Guariba e BRS Novaera, colhidas manualmente, com teor de água de 0,21 (b.s) e 0,16 (b.s), respectivamente, secas até o teor 0,11 (b.s.). O processo de secagem foi realizado em secador experimental sob as temperaturas controladas de 30, 40 e 50 °C, e umidade relativa do ar de secagem entre 14 e 59%. O tempo de secagem para as sementes de feijão-caupi (cultivar BRS guariba) foi de 10,4, 5,6 e 2,1 horas para as temperaturas de 30, 40 e 50 °C, respectivamente; para a cultivar BRS Novaera a secagem foi de 8,7, 4,7 e 2,0 horas para as temperaturas de 30, 40 e 50 °C, respectivamente. O modelo matemático de Midilli foi o que melhor se ajustou aos dados experimentais de ambas as cultivares, apontando que o coeficiente de difusão aumenta com a elevação da temperatura, apresentando valores entre 5,047 x 10-11 a 12,011 x 10-11 m² s-1, para a cultivar BRS Guariba e 2,482 x 10-11 a 5,187 x 10-11 m² s-1, na cultivar BRS Novaera, para a faixa de temperatura de 30 a 50 °C. A relação entre o coeficiente de difusão efetivo e a temperatura de secagem pode ser descrita pela equação de Arrhenius, que apresenta uma energia de ativação de 35,04 kJ.mol-1 e de 29,76 kJ.mol-1 para a difusão líquida no processo de secagem das sementes de feijão-caupi. Após o processo de secagem, as sementes apresentaram percentuais de plântulas normais superiores a 87%; nas diferentes condições de estudo apresentaram baixo vigor, sendo a secagem sob a temperatura de 40 °C a que produziu os resultados mais satisfatórios.
468

CONTROLE ESTATÍSTICO DA QUALIDADE NA IRRIGAÇÃO POR ASPERSÃO / STATISTICAL CONTROL OF QUALITY IN THE SPRINKLER IRRIGATION

Frigo, Jiam Pires 02 June 2014 (has links)
Made available in DSpace on 2017-07-10T19:23:55Z (GMT). No. of bitstreams: 1 Jiam Pires_ Frigo.pdf: 2243207 bytes, checksum: 76a818d3ba4a98ecda459c13486050ca (MD5) Previous issue date: 2014-06-02 / The sprinkler irrigation system is widely used because of the possibility of high uniform distribution and to adapt itself to different crops and soils. On the other hand, the water uniform application in irrigation is affected by meteorological factors that decrease the system efficiency. There has always been some concern about the quality of products and services in human history, since all products should have desirable characteristics to be accepted by consumers. Currently, development, improvement and monitoring of new management models quality during the production process have become essential for many organizations. Thus, inspection control has enhanced by statistical techniques, losses have been decreased and it was possible to stimulate some trading competition. In this context, this study aimed at evaluating the irrigation system in a conventional sprinkler using the Christiansen Uniformity Coefficient (CUC) and the index Process Capability (CP) to correlate techniques with the system efficiency as well as verify the wind influence on irrigation by Shewhart control chart and compare the results of Shewhart control charts use with the EWMA and tabular CUSUM control charts, applied in quality control of the conventional sprinkler irrigation. In this study, 60 essays were carried out on a four irrigation sprinklers system, Xcel-Wobbler model, 1.0 m height above soil and 6.0 x 6.0 m spaced. The collectors were 1.0 m spaced apart with 0.5 m height from soil. The service pressure was monitored and appropriate to the sprinklers specifications, while wind was monitored in situ by a 2.0 m high digital anemometer. In order to evaluate the system, Christiansen Uniformity Coefficient (CUC), the index Process Capability (CP), Shewhart charts (Xbarra) and the charts of exponentially weighted moving average (EWMA) and cumulative sum (CUSUM) were used. The irrigation sprinkler system showed the best performance and was under control when the average wind speed was less than 1.0 m s-1. The use of individual Shewhart control charts visually allowed affirming that wind has a direct influence on CUC. Night irrigation showed less variability on the studied data, when compared to daytime ones and this has resulted in greater efficiency in irrigation. The CPi index showed great similarity with the Christiansen Uniformity Coefficient (CUC). It proved to be very sensitive to efficiency sprinkler (Ea) variation and able to indicate the quality of sprinkler irrigation. The EWMA chart, when compared to the control charts, was susceptible when used in autocorrelated data, according to the occurrence of false alarms. But, to the residue data without autocorrelation (the ARIMA model), the CUSUM tabular chart was more sensitive to detect variations in irrigation due to wind speed, when compared to EWMA and Shewhart charts for the same data. In sprinkler irrigation, when there is a relation between CUC and wind speed, the Shewhart chart was more indicated by simplicity, reliability and ease of interpretation, even in the presence of autocorrelated data. / O sistema de irrigação por aspersão é muito utilizado, devido à possibilidade de elevada uniformidade de distribuição e por adaptar-se às diversas culturas e solos. Porém, a uniformidade de aplicação de água nas irrigações é afetada por fatores meteorológicos que diminuem a eficiência do sistema. A preocupação com a qualidade de produtos e serviços oferecidos sempre esteve presente na história da humanidade, pois para que os produtos fossem aceitos, deveriam possuir características desejáveis pelos consumidores. Atualmente, com o surgimento de novos modelos gerenciais, a melhoria e o monitoramento da qualidade durante o processo de produção tornaram-se uma necessidade para muitas organizações. Assim, aprimorou-se o controle da inspeção por meio de técnicas estatísticas, reduziram-se perdas e foi possível competir no mercado. Neste contexto, o objetivo deste estudo foi avaliar a irrigação em um sistema por aspersão convencional, utilizando o Coeficiente de Uniformidade de Christiansen (CUC), o índice de Capacidade do Processo (CP) para correlacionar as técnicas com a eficiência do sistema, verificar a influência do vento na irrigação pelo gráfico de controle de Shewhart e confrontar os resultados da utilização dos gráficos de controle de Shewhart, com os gráficos de controle MMEP e CUSUM tabular, aplicados no controle de qualidade da irrigação por aspersão convencional. Neste estudo, foram realizados 60 ensaios em um sistema de irrigação por aspersão convencional. O sistema era constituído de quatro aspersores, modelo Xcel-wobbler, altura de 1,0 m em relação ao solo e espaçamento de 6,0 x 6,0 m. Os coletores foram espaçados em 1,0 m entre si com altura de 0,5 m do solo. A pressão de serviço foi monitorada e adequada às especificações dos aspersores, e o vento monitorado in loco, por um anemômetro digital com 2,0 m de altura. Para a avaliação do sistema, foram utilizados o Coeficiente de Uniformidade de Christiansen (CUC), o índice de Capacidade do Processo (CP), gráficos de Shewhart (Xbarra) e os gráficos de média móvel exponencialmente ponderada (MMEP) e de soma cumulativa (CUSUM). O sistema de irrigação por aspersão convencional teve melhor desempenho e esteve sob controle, quando a velocidade média do vento esteve menor que 1,0 m s-1. O uso dos gráficos individuais de controle de Shewhart possibilitou afirmar visualmente que o vento tem influência direta sobre o CUC. A irrigação noturna apresentou menor variabilidade nos dados, quando comparados aos dados do período diurno e isso resultou em maior eficiência na irrigação. O índice CPi teve grande similaridade com o Coeficiente de Uniformidade de Christiansen (CUC); mostrou-se bastante sensível à variação da eficiência de aspersão (Ea) e capaz de indicar a qualidade da irrigação por aspersão. Em comparação aos gráficos de controle, o gráfico MMEP mostrou-se suscetível quando utilizado em dados autocorrelacionados, pelas ocorrências de alarmes falsos. Para dados de resíduos, sem autocorrelação (pelo modelo ARIMA), o gráfico CUSUM tabular foi mais sensível ao detectar as variações ocorridas na irrigação devido à velocidade do vento, quando comparado aos gráficos MMEP e Shewhart para os mesmos dados. Na irrigação por aspersão, relacionando CUC com velocidade do vento, o gráfico de Shewhart foi mais indicado pela simplicidade, confiabilidade e facilidade de interpretação, mesmo na presença de dados autocorrelacionados entre si.
469

Método graus dia para avaliação do desempenho energético de uma edificação unifamiliar em diferentes condições climáticas. / Method degrees-day for evaluation of the energy performance of a construction unifamiliar in different climatic conditions.

Vendramin, Aurea Lúcia 12 July 2007 (has links)
Made available in DSpace on 2017-07-10T19:23:56Z (GMT). No. of bitstreams: 1 Aurea Lucia Vendramini.pdf: 426775 bytes, checksum: 564553d1ce5ca6d797acb90f3cf07ad3 (MD5) Previous issue date: 2007-07-12 / The necessity of the application of climatic data for evaluation of energy performance in unifamiliares constructions if has become each more important time. Attempting against for this fact, one becomes necessary that these 0 variable are worked of form if to get resulted efficient. Studies in this area are very recent in Brazil and also exist a difficulty in the survey of the necessary registers. The present work used a method of degrees - days for an evaluation of the energy performance of a unifamiliar construction it showed - that in the conception of a project architectural it always must be taken in consideration of the materials used in the construction and size of the openings. The energy performance was gotten by means of the model of degrees - days, considering - the localization of the unifamiliar residence in, cities of Cascavel, Curitiba, Foz do Iguaçu and Londrina. For this the climatic data of such localities had been gotten and at as a moment, the energy performance of the construction was gotten the total coefficient of loss of heat in the unifamiliar construction daily pay-established evaluating thus the conditions of thermal comfort. The method of estimate based on the information of used temperature of air in this study can be applied to other geographic localities. It observed - that degrees - days of heating in the winter are of 77.78 for Curitiba and 0.00 for Foz do Iguaçu in the temperature base of 14°C. E degrees - days of cooling 30,17 in the winter. The energy consumed in Foz do Iguaçu to heat the residence is of 4650.07 kWh annual and the consumption of annual energy to heat the residence in Curitiba is of 6277.02 kWh, to change of 50% ITA in double glass. / A necessidade da aplicação de dados climáticos para avaliação de desempenho energético em edificações unifamiliares tem se tornado cada vez mais importante. Atentando para esse fato, é necessário que essas variáveis sejam trabalhadas de forma a se obter resultados eficazes. Estudos na área são muito recentes no Brasil e existe também uma dificuldade no levantamento dos registros necessários. O presente trabalho utilizou um método de graus dias para uma avaliação do desempenho energético de uma edificação unifamiliar que mostrou que na concepção de um projeto arquitetônico devem ser sempre considerados os materiais empregados na edificação e o tamanho das aberturas. O desempenho energético foi obtido por meio do modelo de graus dias, considerando se a localização da residência unifamiliar nas cidades de Cascavel, Curitiba, Foz do Iguaçu e Londrina. Para isso foram obtidos os dados climáticos dessas localidades e, em um segundo momento, foi obtido o coeficiente total de perda de calor na edificação unifamiliar pré-estabelecida avaliando-se assim as condições de conforto térmico o desempenho energético da edificação. O método de estimativa baseado nas informações de temperatura do ar usado neste estudo pode ser aplicado a outras localidades geográficas. Observou se que graus dias de aquecimento no inverno são de 77,78 para Curitiba e de 0,00 para Foz do Iguaçu na temperatura base de 14°C. E graus dias de resfriamento 30,17 no inverno. A energia consumida em Foz do Iguaçu para aquecer a residência é de 4650.07 kWh anual e o consumo de energia anual para aquecer a residência em Curitiba é de 6277.02 kWh, para trocas de 50% de ITA em vidros duplos.
470

Efeitos térmicos na teoria quântica de campos em (2+1) dimensões / Thermal Effects in Quantum Field Theory in (2 +1) dimensions.

Silvana Perez 03 June 2003 (has links)
Efeitos térmicos em teorias de calibre em (2+1) dimensões são estudados em espaços onde as coordenadas podem ou não comutar. No caso comutativo, a dependência com a temperatura do tensor de polarização é calculada a um laço em teorias envolvendo tanto bósons quanto férmions. Como aplicação, são calculados os processos de blindagem em tais modelos, chegando ao interessante resultado de que cargas magnéticas não sofrem tais efeitos na QED3. Uma prova válida em qualquer ordem de perturbação é desenvolvida, confirmando este comportamento. Em teorias não comutativas, são estudadas as correções a um laço ao coeficiente de Chern-Simons, sendo encontrado que não existe o fenômeno da mistura UV/IR na teoria Chern-Simons-Higgs. O comportamento assintótico de tal coeficiente é analisado no regime de altas temperaturas. Vários outros aspectos envolvendo os efeitos térmicos em teorias de Chern-Simons são explorados. / Thermal effects in (2+1)-dimensional gauge theories are studied in both commutative as well as noncommutative manifolds. In the first situation, the finite temperature polarization tensor is computed a tone loop for fermionic and bosonic couplings. As an application, the screening masses are evaluated and it is found the surprising result that magnetic charges are not screened in QED3. It is demonstrated that this result holds to any order in pertubationtheory. In the noncommutative case, the one loop correction to the Chern-Simons coefficient is studied, and it is found that there is no UV/IR mixing in the Chern-Simons-Higgs model. The asymptotic behavior of such coefficient is analised in the high temperature regime. Several other interesting aspects involving thermal effects of Chern-Simons theories are also discussed.

Page generated in 0.0615 seconds