• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 180
  • 11
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 197
  • 197
  • 99
  • 98
  • 69
  • 55
  • 42
  • 38
  • 23
  • 23
  • 22
  • 22
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

\"Avaliação da resistência flexural, microinfiltração e grau de conversão de uma resina composta fotoativada com luz halógena e laser de argônio\" / Evaluation of the flexural strenght, microleakage and degree of convertion of a composite resin photocured with argon laser and halogen lamp.

Lloret, Patricia Ramos 13 February 2007 (has links)
Nesta pesquisa foi avaliado a resistência flexural, a microinfiltração e o grau de conversão de uma resina composta micro-híbrida fotoativada por laser de argônio e luz halógena. Para o teste de resistência flexural e grau de conversão foram preparadas cinco amostras de 25 X 2 X 2mm de acordo com a norma ISO 4049. Os parâmetros de fotoativação utilizados em todas as etapas do trabalho foram: luz halógena (500mW/cm2) por 20 segudos, laser de argônio (250mW) por 10 e 20 segundos. As amostras foram lixadas com a seqüência de granulações 500, 800, 1000, 1200, 2500 e 4000. Os espécimes eram armazenados em água destilada, em recipiente escuro, em estufa a 37ºC por 24 horas e eram submetidos ao ensaio de resistência flexural (Máquina de Ensaios Mecânicos - Modelo 4411 ? Instron) em velocidade de 1mm/min. Para o estudo da microinfiltração foram utilizados dentes incisivos bovinos (n=20), As cavidades eram preparadas com brocas Carbide #330 com 4mm (altura) X 3mm (largura) X 2mm (profundidade). Os dentes eram então restaurados, e recebiam acabamento e polimento e em seguida eram armazenados em água destilada, em estufa a 37ºC por 24 horas. As amostras foram submetidas ao processo de termociclagem (500 ciclos de 30 segundos - 6ºC e 60ºC). Após a termociclagem, os ápices dos dentes eram selados com IRM e adesivo a base de cianoacrilato e imersos em fucsina básica a 0,5% por 24 horas, em estufa a 37ºC. A análise do grau de conversão foi feita com o Espectrômetro FT-Raman RFS 100/S (Bruker). Para o teste de resistência flexural foi realizado o teste de análise de variância, que mostrou não haver diferença estatisticamente significante entre as fontes fotoativadoras estudadas (p>0,05). A microinfiltração das margens oclusais (em esmalte) e gengivais (em dentina) dos três grupos foram analisadas separadamente por meio do teste de Mann-Whitney. Houve diferença estatisticamente significante ao nível de 5% entre esmalte e dentina, sendo que em todos os grupos a microinfiltração em dentina foi maior que em esmalte. O teste nãoparamétrico Kruskall-Wallis foi utilizado separadamente nas comparações entre as fontes para as análises do grau de microinfiltração em esmalte e dentina. Não houve diferença estatisticamente significante em ambas as comparações, sendo o valor de H= 0,1283 para esmalte e de H=2,3083 para em dentina. Para a análise do grau de conversão foi realizada a análise de variância (ANOVA) entre os grupos. Não houve diferença estatisticamente significante entre as fontes. Diante dos resultados obtidos, pode-se afirmar que o laser de argônio apresentou qualidade de fotoativação semelhante à da luz halógena e que nenhuma fonte ativadora estudada foi capaz de evitar a microinfiltração. / In the research was evaluated the flexural strength, the microleakage and the degree of conversion of a micro-hybrid composite resin photocured with argon laser and halogen lamp. For both flexural test and degree of conversion analysis five bar samples of composite resin (25 X 2 X 2mm) were prepared and polymerized following the ISO 4049. The light cured unit halogen was used with 500mW/cm2 for 20 seconds and the argon laser with 250mW for 10 and 20 seconds. After curing, samples were removed from the molds, polished using silicon carbide paper up to 4000 grit-number and stored in distilled water in dark environment at 37oC for 24 hours. The flexural property was quantified by a three-point loading test (Model 4411, Instron Corp., Canton, MA) with a cross-head speed of 1,0mm/min. To microleakage test sixty bovine incisors were used to prepare standardized class V cavities that were restored and polished. The specimens were stored in water for 24 hours at 37oC and thermocycled 500 times between water baths kept at 5 oC and 55 oC. After thermocycling, specimens were immersed in a aqueous solution of basic fuchsin for 24 hours. Longitudinal sections of each restoration were obtained and examined with a stereomicroscope for qualitive evaluation of microleakage. FTRaman RFS 100/S spectrometer (Bruker) was used to analyse the degree of conversion. The ANOVA test showed that there were no statistically significant difference of the flexural setrength between the photo-activation types evaluated in the flexural study. Microleakage data was statistically analysed by Mann-Whitney and Kruskall-Wallis tests. Enamel margins resulted in statistical lower degree of leakage than dentin margins. There was no statistically significant difference between the three types of photo-curing studied. The ANOVA test also showed that there were no statistically significant difference of the degree of conversion between the studied groups. According to the methodology used in this research it was concluded that the argon laser is a posible alternative for photocuring, providing the same quality of polymerization as do the halogen lamp. None of the photocured units tested in this study completely eliminated microleakage.
192

Efeito do número de pinos de fibra de vidro na resistência à fratura, deformação estrutural e distribuição de tensão em molares tratados endodonticamente

Barcelos, Luciana Mendes 12 February 2016 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The aim of this study was to evaluate the biomechanical effect of the presence and number of fibreglass post in endodontically treated molars restored with composite resin. 45 human molars were selected, included in polystyrene resin cylinders with simulation of the periodontal ligament and endodontically treated. These teeth were randomized into three groups (n = 15): Wfgp, without fibreglass post and restored with Filtek Z350 XT; 1fgp, 1 fiberglass post Exact #2 cemented in the distal root with RelyX U200 and restored with Z350XT; and 2fgp, 2 fiberglass posts cemented with RelyX U200, one in the distal root and the other in the mesiobuccal root, restored with Z350XT. The specimens were submitted to mechanical fatigue with axial load of 50N. The tooth remaining deformation was measured using extensometers (n = 10) during occlusal loading of 100N and then until fracture. The other teeth (n = 5) were used to calculate the modulus of elasticity (GPa) and Vickers hardness (VH, N/mm2) of the enamel, dentin composite resin and fiberglass post in two positions: parallelly and transversally to the long axis of the post. The stress distribution was analyzed using three dimensional finite elements model, generated from micro-CT image of an intact tooth with its geometry similar of those used in the in vitro study. The calculated mechanical properties were used to characterize models of finite element analysis. The data of deformation and fracture resistance were tested for normality (Shapiro-Wilk) and equivalence of variances (test Levene), followed by parametric statistical tests appropriated for each test. One way Anova was performed for the axial compressive strength values, tooth remaining deformation and fracture resistance. Multiple comparisons were performed using Tukey test. The mean fracture data were submitted to the Chi-square test. Factorial analysis of variance on two factors was carried out considering as factors in study: the tooth surface deformation (B and L) and rehabilitation technique. All tests done had significance level α = 0.05 and all analyses were performed with the statistical program Sigma Plot version 13.1 (Systat Software, San Jose, CA, USA). The use of two fiber glass posts resulted in lower fracture resistance than the groups without fiber glass - 22 - post and with one fiber glass post. During occlusal loading of 100N lingual surface of the remaining tooth showed higher deformation for all groups. The absence of fiber glass post resulted in significantly higher values of stress in the root and more irreparable fracture modes than the other groups. The use of a fiber glass post resulted in better ratio deformation/fracture resistance. The concentration of stress in the furcation area was slightly reduced with use of fiber glass post. It is concluded that the use of one fiber glass post to rehabilitated molars with direct composite resin showed higher resistance to fracture than the use of two fiberglass posts, lower tooth remaining deformation, better stress distribution and failure pat more repairable when compared to molars restored without use of fiber-glass post / O objetivo deste trabalho foi avaliar o efeito biomecânico da presença e do número de pinos de fibra de vidro em molares tratados endodonticamente e restaurados de forma direta com resina composta. Quarenta e cinco molares humanos foram selecionados, incluídos em cilindros de resina de poliestireno com simulação do ligamento periodontal e tratados endodonticamente. Estes dentes foram randomizados em três grupos (n=15): Spfv, sem pino de fibra de vidro, restaurado com Filtek Z350XT; 1pfv, 1 pino de fibra de vidro Exacto Nº 2 cimentado no canal distal com RelyX U200 restaurado com Z350XT; e 2pfv, 2 pinos de fibra de vidro Exacto Nº 2 cimentados com RelyX U200, um no canal distal e o outro no mesio-vestibular restaurado com Z350XT. As amostras foram submetidas à fadiga mecânica com carregamento axial de 50N. A deformação do remanescente foi mensurada usando extensômetros (n=10) durante o carregamento oclusal de 100N e em seguida até o momento de fratura. Os demais dentes (n=5) foram usados para calcular o módulo de elasticidade (E, GPa) e dureza Vickers (VH, N/mm2) do esmalte, dentina, resina composta e pino de fibra de vidro em duas posições: paralelamente e transversalmente ao longo eixo do pino. A distribuição de tensões foi analisada usando modelo tridimensional de elementos finitos gerado a partir de imagem de micro-CT de um dente hígido com medidas e geometrias representativo das amostras usadas na etapa experimental. Às propriedades mecânicas calculadas foram utilizadas para caracterizar os modelos da análise por elementos finitos. Os dados de deformação e resistência à fratura foram submetidos à teste de normalidade (Shapiro-Wilk) e equivalência de variâncias (teste de Levene), seguido por testes estatísticos paramétricos adequados para cada tipo de ensaio. Análise de variância em fator único foi realizada para os valores de resistência à compressão axial, deformação do remanescente e resistência à fratura. Comparações múltiplas foram realizadas usando teste de Tukey. Os dados de padrão de fratura foram submetidos ao teste Quiquadrado. Análise de variância fatorial em dois fatores foi realizada considerando como fatores em estudo: deformação da superfície do remanescente (V e L) e a técnica de reabilitação. Todos os testes empregados - 19 - tiveram nível de significância α=0,05 e todas as análises foram realizadas com o programa estatístico Sigma Plot versão 13.1 (Systat Software Ins, San Jose, CA, USA). O uso de dois pinos de fibra de vidro resultou em menor resistência à fratura que os grupos sem pino de fibra de vidro e com um pino de fibra de vidro. Durante o carregamento oclusal de 100N a superfície lingual do remanescente demonstrou maior deformação para todos os grupos. A ausência de pino de fibra de vidro resultou em valores significativamente mais elevados de tensões na dentina radicular e modos de fratura irreparáveis significativamente maiores que os outros grupos. O uso de um pino de fibra de vidro resultou em melhor razão deformação/resistência fratura. A concentração de tensão na área de furca foi ligeiramente reduzida com uso de pino de fibra de vidro. Conclui-se que o uso de um pino de fibra de vidro para reabilitar molares inferiores com resina composta direta mostrou maior resistência à fratura que o uso de dois pinos de fibra de vidro, menor deformação do remanescente, melhor distribuição de tensões e padrão de falha com maior número de fraturas reparáveis quando comparado a molares restaurados sem uso de pino de fibra de vidro / Mestre em Odontologia
193

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Andréa Ferreira Santos da Cruz 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.
194

Anticariogenic in situ effect of different restorative dental materials / AvaliaÃÃo in situ do efeito anticariogÃnico de diferentes materiais restauradores

Rosane Pontes de Sousa 24 April 2008 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Tooth structure immediately adjacent to restorations is susceptible to secondary caries, which may be caused by imperfect adaptation of restorative materials and subsequent microorganism colonization. Therefore, in order to identify methods of preventing secondary caries and increasing clinical dental restoration durability, different restorative dental materials have been introduced and applied in dental clinics. Thus, this in situ study assessed the effects of different restorative materials on the microbiological composition of dental biofilm and evaluated their ability of protecting the adjacent enamel against acid attacks from bacterial activity. A double-blind, split-mouth design was performed in one phase of 14 days, during which, 20 volunteers wore intra-oral palatal devices with five human enamel slabs, which were extra-orally restored according to the manufacturerâs specifications, using one of the following materials: Filtek Z 250/Single Bond composite resin; Permite amalgam; Fuji II encapsulated resin-modified glass ionomer; Vitremer resin-modified glass ionomer and Ketac Molar conventional glass ionomer.. During the experimental period, all subjects used fluoride-containing dentifrice 3x/day and a 20% sucrose solution was dripped onto the slabs 8x/day in predetermined times. The biofilm formed on the slabs was analyzed to determine total and mutans streptococci as well as lactobacilli counts. Demineralization (delta S) was determined on enamel by cross-sectional microhardness at 20 and 70 -Âm from the restoration margin. In order to verify the differences among the treatments, Kruskal-Wallis and ANOVA followed by Minimum Squares test were applied for cariogenic microbiota and delta S, respectivly. No statistically significant differences were found in the cariogenic microbiota grown on the slabs. At 20-Âm distance, only Fuji II statistically differed from the other groups presenting the lowest demineralization. At 70-Âm, Fuji II significantly inhibited demineralization when compared to Permite, Filtek-Z-250 and Ketac Molar. Concluding, in the background of fluoride dentifrice and under the cariogenic exposure condition of this study, only the encapsulated resin-modified glass ionomer material provided additional protection against secondary caries. / A estrutura dentÃria imediatamente adjacente a restauraÃÃes à suscetÃvel ao surgimento de cÃrie secundÃria, que pode ocorrer devido a imperfeiÃÃes na adaptaÃÃo de materiais restauradores e subseqÃente colonizaÃÃo por microrganismos. Logo, com o objetivo de identificar os mÃtodos de prevenÃÃo da cÃrie secundÃria e aumentar a longevidade das restauraÃÃes, diferentes materiais restauradores tÃm sido introduzidos e usados na clÃnica odontolÃgica. Desta forma, este estudo in situ avaliou os efeitos de diferentes materiais restauradores na composiÃÃo microbiolÃgica do biofilme dental bem como a habilidade destes materiais em proteger o esmalte adjacente dos ataques Ãcidos provenientes da atividade bacteriana. Foi empregado um delineamento duplo-cego, âsplit-mouthâ realizado em uma fase de 14 dias, durante a qual, 20 voluntÃrios utilizaram dispositivos intra-orais palatinos com cinco blocos de esmalte dental humano que foram restaurados extra-oralmente, de acordo com as recomendaÃÃes do fabricante com um dos seguintes materiais: Resina composta Filtek Z250/Single Bond (grupo controle), AmÃlgama Permite, IonÃmero de vidro modificado por resina encapsulado Fuji II, IonÃmero de vidro modificado por resina Vitremer e IonÃmero de vidro convencional Ketac Molar. Durante o perÃodo experimental, os voluntÃrios utilizaram dentifrÃcio fluoretado, 3 vezes ao dia e gotejaram sobre os blocos, uma soluÃÃo de sacarose a 20%, 8 vezes ao dia em horÃrios prÃ-determinados. No 14o dia, o biofilme formado sobre os blocos foi removido para determinar a contagem de estreptococos totais e estreptococos mutans, bem como lactobacilos. A desmineralizaÃÃo (delta S) ao redor da restauraÃÃo foi avaliada atravÃs da anÃlise de microdureza em corte longitudinal do esmalte a 20 e 70 Âm da margem da restauraÃÃo. Para detectar as diferenÃas entre os tratamentos, foram aplicados os testes Kruskal-Wallis e ANOVA seguida do teste dos quadrados mÃnimos para a microbiota cariogÃnica e delta S, respectivamente. NÃo foram encontradas diferenÃas estatisticamente significativas na microbiota cariogÃnica formada sobre os blocos. Na distÃncia 20 Âm, somente o Fuji II diferiu estatisticamente dos outros grupos apresentando a menor desmineralizaÃÃo. A 70 Âm, o Fuji II inibiu significativamente a desmineralizaÃÃo quando comparado ao Permite, Filtek-Z-250 e Ketac Molar. Conclui-se que na situaÃÃo de uso de dentÃfricio flouretado associada ao desafio cariogÃnico do presente estudo, somente, o ionÃmero de vidro modificado por resina encapsulado apresentou uma proteÃÃo adicional contra o desenvolvimento de cÃrie secundÃria
195

\"Avaliação da resistência flexural, microinfiltração e grau de conversão de uma resina composta fotoativada com luz halógena e laser de argônio\" / Evaluation of the flexural strenght, microleakage and degree of convertion of a composite resin photocured with argon laser and halogen lamp.

Patricia Ramos Lloret 13 February 2007 (has links)
Nesta pesquisa foi avaliado a resistência flexural, a microinfiltração e o grau de conversão de uma resina composta micro-híbrida fotoativada por laser de argônio e luz halógena. Para o teste de resistência flexural e grau de conversão foram preparadas cinco amostras de 25 X 2 X 2mm de acordo com a norma ISO 4049. Os parâmetros de fotoativação utilizados em todas as etapas do trabalho foram: luz halógena (500mW/cm2) por 20 segudos, laser de argônio (250mW) por 10 e 20 segundos. As amostras foram lixadas com a seqüência de granulações 500, 800, 1000, 1200, 2500 e 4000. Os espécimes eram armazenados em água destilada, em recipiente escuro, em estufa a 37ºC por 24 horas e eram submetidos ao ensaio de resistência flexural (Máquina de Ensaios Mecânicos - Modelo 4411 ? Instron) em velocidade de 1mm/min. Para o estudo da microinfiltração foram utilizados dentes incisivos bovinos (n=20), As cavidades eram preparadas com brocas Carbide #330 com 4mm (altura) X 3mm (largura) X 2mm (profundidade). Os dentes eram então restaurados, e recebiam acabamento e polimento e em seguida eram armazenados em água destilada, em estufa a 37ºC por 24 horas. As amostras foram submetidas ao processo de termociclagem (500 ciclos de 30 segundos - 6ºC e 60ºC). Após a termociclagem, os ápices dos dentes eram selados com IRM e adesivo a base de cianoacrilato e imersos em fucsina básica a 0,5% por 24 horas, em estufa a 37ºC. A análise do grau de conversão foi feita com o Espectrômetro FT-Raman RFS 100/S (Bruker). Para o teste de resistência flexural foi realizado o teste de análise de variância, que mostrou não haver diferença estatisticamente significante entre as fontes fotoativadoras estudadas (p>0,05). A microinfiltração das margens oclusais (em esmalte) e gengivais (em dentina) dos três grupos foram analisadas separadamente por meio do teste de Mann-Whitney. Houve diferença estatisticamente significante ao nível de 5% entre esmalte e dentina, sendo que em todos os grupos a microinfiltração em dentina foi maior que em esmalte. O teste nãoparamétrico Kruskall-Wallis foi utilizado separadamente nas comparações entre as fontes para as análises do grau de microinfiltração em esmalte e dentina. Não houve diferença estatisticamente significante em ambas as comparações, sendo o valor de H= 0,1283 para esmalte e de H=2,3083 para em dentina. Para a análise do grau de conversão foi realizada a análise de variância (ANOVA) entre os grupos. Não houve diferença estatisticamente significante entre as fontes. Diante dos resultados obtidos, pode-se afirmar que o laser de argônio apresentou qualidade de fotoativação semelhante à da luz halógena e que nenhuma fonte ativadora estudada foi capaz de evitar a microinfiltração. / In the research was evaluated the flexural strength, the microleakage and the degree of conversion of a micro-hybrid composite resin photocured with argon laser and halogen lamp. For both flexural test and degree of conversion analysis five bar samples of composite resin (25 X 2 X 2mm) were prepared and polymerized following the ISO 4049. The light cured unit halogen was used with 500mW/cm2 for 20 seconds and the argon laser with 250mW for 10 and 20 seconds. After curing, samples were removed from the molds, polished using silicon carbide paper up to 4000 grit-number and stored in distilled water in dark environment at 37oC for 24 hours. The flexural property was quantified by a three-point loading test (Model 4411, Instron Corp., Canton, MA) with a cross-head speed of 1,0mm/min. To microleakage test sixty bovine incisors were used to prepare standardized class V cavities that were restored and polished. The specimens were stored in water for 24 hours at 37oC and thermocycled 500 times between water baths kept at 5 oC and 55 oC. After thermocycling, specimens were immersed in a aqueous solution of basic fuchsin for 24 hours. Longitudinal sections of each restoration were obtained and examined with a stereomicroscope for qualitive evaluation of microleakage. FTRaman RFS 100/S spectrometer (Bruker) was used to analyse the degree of conversion. The ANOVA test showed that there were no statistically significant difference of the flexural setrength between the photo-activation types evaluated in the flexural study. Microleakage data was statistically analysed by Mann-Whitney and Kruskall-Wallis tests. Enamel margins resulted in statistical lower degree of leakage than dentin margins. There was no statistically significant difference between the three types of photo-curing studied. The ANOVA test also showed that there were no statistically significant difference of the degree of conversion between the studied groups. According to the methodology used in this research it was concluded that the argon laser is a posible alternative for photocuring, providing the same quality of polymerization as do the halogen lamp. None of the photocured units tested in this study completely eliminated microleakage.
196

Molares permanentes de pacientes jovens com cárie profunda versus tratados endodonticamente e restaurados com resina composta bulk fill – Análise da força de mordida e por elementos finitos específico / Pulp caries affected versus endodontic treated and composite resin restored young permanent molars -bite force and specific finite element analysis

Rodrigues, Monise de Paula 09 February 2018 (has links)
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPEMIG - Fundação de Amparo a Pesquisa do Estado de Minas Gerais / O tratamento endodôntico associado à restauração direta com resina composta tem sido utilizado para restaurar molares severamente destruídos em pacientes jovens. O objetivo deste estudo foi avaliar o efeito de diferentes níveis de perda de estrutura dentária antes e após a realização de tratamento endodôntico e restauração com resina composta bulk fill na distribuição de tensões e magnitude da força de mordida. Foram selecionados três pacientes jovens (9, 10 and 12 anos de idade) com primeiros molares com cárie extensa e envolvimento pulpar com diferentes níveis de perdas de estrutura dentária: PI, manutenção das duas cristas marginais e de todas as cúspides; PII, manutenção de pelo menos uma crista marginal e perda mínima de uma cúspide; e PIII, perda de ambas as cristas marginais, mantendo apenas as cúspides vestibulares. Os molares foram tratados endodonticamente utilizando técnica de instrumentação rotatória e obturados com guta-percha e cimento AHPlus (Dentsply) e em seguida foram restaurados com Filtek Bulk Fill Posterior (3M ESPE). A força de mordida em Newtons (N) foi mensurada antes e após a intervenção endodôntica e restauradora na posição habitual de oclusal usando aparelho de força de mordida por meio de uma célula de carga (Kratos). Tomografias computadorizadas cone beam foram realizadas antes e após o procedimento endodôntico/restaurador, e arquivos DICOM (.dcm) foram exportados para o software Mimics, 3-Matic (Materialize) e Patran (MSC Software) para criação dos modelos específicos dos pacientes nos dois momentos experimentais. A aplicação de carga foi simulada por contato oclusal dos dentes antagonistas nas cargas mensuradas clinicamente em cada momento. Nos modelos que representam as condições iniciais foram aplicados tanto os valores de força de mordida (N) mensurados no momento inicial quanto após o procedimento reabilitador: PI. 30,1/136,6; PII. 34,3/133,4 e PIII. 47,9/124,1 e para os modelos que representam a condição final foram utilizados os valores obtidos após a intervenção endodôntica e restauradora: PI. 136,6; PII. 133,4 e PIII. 124,1. As restaurações foram avaliadas após 2 anos. Após intervenção endodôntica e restauradora a força de mordida aumentou em 260% (de 36,7±11,6 para 12 131,9±17,8). Antes da intervenção endodôntica e restauradora, as tensões se concentraram na estrutura coronal e, após a reabilitação foram transferidas de forma homogênea para a dentina radicular, independente do nível de perda de estrutura dentária. Quando a carga final foi aplicada nos modelos de condições iniciais, evidenciou-se elevada concentração de tensão em áreas enfraquecidas e na região de furca. As restaurações apresentaram desempenho adequado após 2 anos. A presença de cárie extensa com envolvimento pulpar afetou negativamente a carga de mordida e aumentou a concentração de tensão na estrutura frágil o que pode favorecer à ocorrência de fratura dental. O tratamento endodôntico associado à restauração direta em resina composta bulk fill demonstrou ser um método eficiente para restabelecer o desempenho mastigatório e a eficiência biomecânica dos molares jovens com comprometimento severo da estrutura coronária. / Endodontic treatment (ETT) followed by direct composite resin restoration has been used for rehabilitating the severely damage molar teeth in young patients. The aim of this study was to evaluate the effect of the molar teeth with different levels of the dental structure loss before and after the ETT and direct restoration with bulk fill resin composite on the stress distribution and the bite force magnitude. Three young patients (with 9, 10 and 12 years old), with the first mandibular molar teeth with deep occlusal caries with pulp involvement were selected attending with different levels of the dental structure loss: PI, both marginal ridge and all cusps; PII, maintenance of one marginal ridge and loss of one cusp; and PIII, loss of both marginal ridge, maintaining only buccal cusps. ETT was restored using Filtek Bulk Fill Posterior (3M ESPE). The bite forces in Newtons were measured initially and postoperatively for all teeth in habitual bite force using a miniload cell. Cone-beam tomography imaging was performed, and the Digital Imaging and Communication in Medice (.dcm) files were exported to Mimics, 3-Matic (Materialise) and Patran (MSC Software) software to create a patient-specific FEA models. Bite load was carry out using contact load applied by antagonist teeth in two moments: without ETT and restoration: PI. 30.1/136.6; PII. 34.3/133.4 and PIII. 47.9/124.1; and after restorative procedure: PI. 136.6; PII. 133.4 and PIII. 124.1 N. Performing ETT and bulk fill resin composite restoration the bite load increased 260% (36.7±11.6) to 131.9±17.8). The restorations were evaluated after 2 years. Before rehabilitation the stresses concentrated on weakened coronal dental structure and after rehabilitation they were homogeneously transferred to root dentin, irrespective of the level of the tooth structure loss. When the postoperatively bite load was applied on nontreated tooth models, high stress concentration on weakened areas was verified. The restorations performed perfectly after 2 years. The extensive caries with pulp involvement affected negatively the bite load and increased the stress concentration on weakened areas and at furcation favoring the tooth fracture. The ETT and bulk fill resin composite restoration showed to be an efficient method for rehabilitate the biomechanical performance of molar teeth of young patients severely compromised structurally. / Dissertação (Mestrado)
197

Photo-Curing Through Single Apertures: The Phenomenon and Its Influence On Polymerization

MacPherson, Meoghan Elizabeth January 2013 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Reduction of the polymerization shrinkage stress inherent of dimethacrylate-based resin composites has been a work in progress since the phenomenon was first described by Dr. Rafael L. Bowen in 1967. Contemporary efforts to modify the composites or the curing protocols for polymerization have proven a challenging task with controversial results. Influenced by existing mathematical models relating exposure, curing time and depth of cure of resin composites, a novel method for the reduction of polymerization shrinkage stress is proposed. By polymerizing through a single aperture mask, a dental light curing unit is transformed from a planar light source to a point light source, and a fully cured, three-dimensional “bullet” shaped curing front is predicted for the cured resin below. So long as the edges of the bullet do not touch the cavity walls or floor, the shrinkage stress of the bullet is not transferred. Follow-up with an unmasked curing unit then fully polymerizes the restoration. By reducing the volume of uncured composite in contact with the cavity walls and floor, shrinkage stress of the restoration is also reduced. The objective of the present study was to demonstrate this curing phenomenon with a model resin composite using masks with aperture diameters of 0.5, 0.4, and 0.25 mm and curing times of 10, 20, 30, and 40 seconds. The resulting curing front was evaluated quantitatively and qualitatively. From this, mathematical models of the curing front were derived. Selected combinations of aperture mask and curing time were then investigated to evaluate the influence of this phenomenon on the degree of conversion, Knoop hardness, and polymerization shrinkage stress of the same model resin composite. Group differences were analyzed using a one-way ANOVA at 5% significance.

Page generated in 0.0753 seconds