• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 234
  • 172
  • 79
  • 42
  • 23
  • 17
  • 14
  • 12
  • 6
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 720
  • 401
  • 177
  • 157
  • 144
  • 114
  • 98
  • 74
  • 73
  • 72
  • 72
  • 69
  • 64
  • 58
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

OFDM Coupled Compressive Sensing Algorithm for Stepped Frequency Ground Penetrating Radar

Metwally, Mohamed 01 January 2014 (has links)
Dating back to as far as 1940, the US road and bridge infrastructure system has garnered quite the status for strategically connecting together half a continent. As monumental as the infrastructure's status, is its rate of deterioration, with the average bridge age coming at a disconcerting 50 years. Aside from visual inspection, a battery of non-destructive tests were developed to conduct structural fault assessment and detect laminations, in order to preemptively take preventive measures. The mainstream commercially favored test is the impulse time domain ground penetrating radar (GPR). An extremely short, high voltage pulse is used to visualize cross-sections of the bridge decks. While effective and it does not disturb traffic flow, impulse radar suffers from major drawbacks. The drawbacks are namely, its limited dynamic range and high cost of system manufacturing. A less prominent yet highly effective system, stepped frequency continuous wave (SFCW) GPR, was developed to address the aforementioned drawbacks. Mostly developed for research centers and academia, SFCW boasts a high dynamic range and low cost of system manufacturing, while producing comparable if not identical results to the impulse counterpart. However, data procurement speed is an inherent problem in SFCW GPR, which seems to keep impulse radar in the lead for production and development. I am proposing a novel approach to elevate SFCW's data acquisition speed and its scanning efficiency altogether. This approach combines an encoding method called orthogonal frequency division multiplexing (OFDM) and an emerging paradigm called compressive sensing (CS). In OFDM, a digital data stream, the transmit signal, is encoded on multiple carrier frequencies. These frequencies are combined in such a way to achieve orthogonality between the carrier frequencies, while mitigating any interference between said frequencies. In CS, a signal can be potentially reconstructed from a few samples below the standardized Nyquist rate. A novel design of the SFCW GPR architecture coupled with the OFDM-CS algorithm is proposed and evaluated using ideal channels and realistically modelled bridge decks.
302

Diseño de mezcla de concreto permeable para la construcción de la superficie de rodadura de un pavimento de resistencia de 210 kg/cm2 / Mix design of pervious concrete for the construction of the rolling surface of a pavement of 210 kg/cm2 compressive strength

Amorós Morote, Carlos Enrique, Bendezú Ulloa, José Carlos 09 August 2019 (has links)
El concreto permeable es un concreto especial, el cual permite el paso del agua a través de su estructura gracias al alto porcentaje de vacíos que posee a diferencia del concreto tradicional. Esta cualidad del concreto permeable permite acabar con la falta de permeabilidad en las estructuras tradicionales de concreto evitando las fallas estructurales debido al encharcamiento y escurrimiento del agua. En esta investigación se realizó el diseño de mezcla del concreto permeable con una resistencia de 210 kg/cm2, aplicando el método ACI 522.R para poder aplicarlo como una alternativa de carpeta de rodadura en pavimentos. Para ello se realizaron diferentes diseños de mezcla en laboratorio hasta encontrar el diseño óptimo para obtener una resistencia a la compresión de 210 kg/cm2, el diseño de mezcla elegido contaba con las siguientes características: relación agua/cemento de 0.38, porcentaje de vacíos de 13%, 1.5% de aditivo Superplastificante y 7% de arena. Para validar la investigación se realizó la construcción de un prototipo con el diseño elaborado en laboratorio con un área de 2.00 m2 (1.00m x 2.00m). Al concreto en estado fresco se le analizaron sus características de consistencia, densidad y contenido de vacíos; en el estado endurecido se realizaron los ensayos de compresión, permeabilidad y flexión, además de aplicarle una prueba de carga. Los resultados indicaron que el diseño de mezcla usado en el prototipo con resistencia a la compresión de 261.58 kg/cm2 y permeabilidad de 0.01744 m/s puede usarse como alternativa de superficie de rodadura para un pavimento. / Pervious concrete is a special type of concrete which allows the passage of water through its structure due to its high percentage of voids unlike traditional concrete. This quality of pervious concrete allows to end the lack of permeability in traditional concrete structures thus preventing structural failures due to flooding and water runoff. This research will seek to find a mix design for pervious concrete to apply it as an alternative road surface for pavements. To verify the above, different mix designs were performed in laboratory to find the design that give us a compressive strength of 210 kg/cm2, the chosen design had the following features: water - cement ratio of 0.38, 13% air content, 1.5% additive superplasticizer and 7% of sand. To validate the research, a prototype was built with the chosen mix design, this prototype had an area of 2 m2 (1m x 2m). The fresh concrete was analyzed for its consistency, density, and void percentage; the hardened concrete was analyzed for its compressive strength, permeability and flexural strength, finally the prototype was load tested. The results indicated that the mix design used in the prototype with compressive strength of 261.58 kg/cm2 and a permeability of 0.01744 m/s can be used as an alternative rolling surface for pavements. / Tesis
303

Propriedades e adesão de cimentos de ionômero de vidro modificados por resina e vitrocerâmicas bioativas / Properties and adhesion of glass ionomer cements modified by resin and bioactive glass-ceramic

Fagundes, Ticiane Cestari 17 February 2009 (has links)
As vitrocerâmicas bioativas são materiais sintéticos capazes de aderirem quimicamente aos minerais presentes na estrutura dentária. A união dos cimentos de ionômero de vidro modificados por resina (CIVMRs) à dentina pode ser influenciada por diferentes tipos de tratamentos prévios à restauração. Os objetivos deste estudo foram: avaliar a resistência à compressão, a rugosidade e a adesão à dentina de CIVMRs (Fuji II LC e Vitremer) após a incorporação de partículas de vitrocerâmicas bioativas (Biosilicato®); foi ainda, avaliar a resistência à degradação da adesão à dentina dos CIVMRs, utilizando-se EDTA como pré-tratamento dentinário. Para o teste de resistência à compressão foram confeccionados cilindros sendo que 2, 5 e 10 % em peso de partículas de vitrocerâmica bioativa foram incorporadas aos pós dos CIVMRs, armazenados em água destilada por 24h a 37°C até a realização dos testes. A rugosidade dos cimentos experimentais (2% de vitrocerâmica bioativa) e controles foi avaliada por microscopia de força atômica (MFA) após armazenamento a seco e em 100 % de umidade por 1 mês. Para os testes de microtração, as superfícies das cavidades foram tratadas seguindo-se as instruções dos fabricantes ou utilizando-se EDTA. Os espécimes foram restaurados com os CIVMRs experimentais (2% de vitrocerâmica) e controles. Após as restaurações, os espécimes foram armazenados em água por 24h e 7d. Para o teste de degradação, os CIVMRs foram armazenados por 24h, 3m e imersos em 10% de hipoclorito de sódio por 5h. Os dentes foram seccionados em palitos e submetidos ao teste de microtração. ANOVA e teste de múltiplas comparações foram realizados (p<0,05). O modo de fratura foi classificado em adesivo, misto e coesivo e alguns espécimes foram analisados em microscopia eletrônica de varredura (MEV). Apenas os cimentos com 2% de vitrocerâmica bioativa obtiveram resistência a compressão semelhante ao grupo controle. Para os grupos controles, Fuji II LC apresentou-se mais rugoso que o Vitremer e o seu armazenamento à seco aumentou sua rugosidade. A condição de armazenamento, seco ou úmido, não afetou a rugosidade dos CIVMRs experimentais. A vitrocerâmica bioativa aumentou significantemente a adesão à dentina dos CIVMRs após armazenamento por 24h, exceto para o Fuji II LC quando EDTA foi utilizado. A aplicação de EDTA aumentou significantemente os valores de resistência adesiva. No estudo de degradação da união, valores de resistência adesiva significantemente maiores foram obtidos nos grupos onde a dentina foi pré-tratada com EDTA. A resistência adesiva do Fuji II LC à dentina não foi afetada pelos métodos de degradação utilizados. Valores de resistência adesiva significantemente menores foram observados para os espécimes restaurados com Vitremer após os dois métodos de degradação, exceto quando a dentina foi prétratada com EDTA. As falhas do tipo mistas foram prevalentes. Em conclusão, 2% de partículas de vitrocerâmica bioativa podem ser incluídas nos CIVMRs sem afetar suas propriedades mecânicas. A rugosidade dos CIVMRs experimentais não foi afetada pelo meio de armazenamento. A inclusão de vitrocerâmicas bioativas aumentou a resistência adesiva somente após armazenamento de 24h. A utilização de EDTA como pré-tratamento dentinário aumentou a resistência adesiva para todas as condições e preveniu a degradação da interface adesiva do Vitremer. / Bioactive glass-ceramics are synthetic materials capable of chemically bonding to dental structures. Adhesion of resin-modified glass-ionomer cements (RMGICs) to dentin may be influenced by different types of dentin pre-treatments. The objective of this study was to analyze the compressive strength, roughness and adhesion to dentin of RMGICs (Fuji II LC and Vitremer) after the incorporation of bioactive glassceramic particles (Biosilicate). Additionally, the durability of the RMGICs adhesion was analyzed after the application of EDTA as a pre-treatment of dentin. Cylinders of RMGICs with incorporation of 2, 5 and 10 % in weight of bioactive glass-ceramic particles were made for compressive strength, and stored in water for 24h at 37°C. Roughness of control and experimental (2% bioactive glass-ceramic) RMGICs was analyzed by atomic force microscopic (MFA) after storage in dry and humidity conditions for 1 month. For the microtensile test, the surfaces of the cavities were treated following the manufacturers instructions or by applying EDTA. The cavities were restored with control and experimental (2% bioactive glass-ceramic) RMGICs. After restorations, the specimens were stored in water for 24h and 7 days. For the degradation test, the RMGICs were stored for 24h, 3 months or immersed in 10% NaOCl for 5h. Teeth were sectioned in beams and submitted to microtensile test. ANOVA and multiple-comparisons tests were used (p<0.05). Mode of failure was classified in adhesive, mixed and cohesive, some specimens were analyzed by scanning electronic microscopic. Only the RMGICs with 2% of bioactive glassceramic obtained compressive strength similar to the control RMGICs. The storage conditions, dry or humidity, did not affect the roughness of experimental RMGICs. Bioactive glass-ceramic significantly increased the adhesion to dentin of RMGICs after storage for 24h, except for Fuji II LC when EDTA was applied. The application of EDTA significantly increased the values of bond strength. For the degradation study, high values of bond strength were also observed in groups where the dentin was pre-treated with EDTA. The bond strength of Fuji II LC to dentin was not affected by the degradation methods. Vitremer specimens presented significantly lower bond strength values after degradation methods, except when EDTA was applied. Mixed failures were the most prevalent in all groups. In conclusion, 2% of bioactive glassceramic particles may be included in RMGICs without affecting their mechanical properties. Roughness of experimental RMGICs was not affected by storage conditions. The incorporation of bioactive glass-ceramic increased the bond strength after storage for 24h. The application of EDTA as a pre-treatment of dentin increased the bond strength for all conditions studied and prevented the degradation of adhesive interface of Vitremer.
304

Distribuição dinâmica de sobrecargas no pé durante a corrida em diferentes pisos / In-shoe dynamic foot loading during running in different running surfaces

Tessutti, Vitor Daniel 15 December 2008 (has links)
Associado ao aumento do número de praticantes de corrida, houve o aumento proporcional no número de lesões em corredores. Esta ocorrência pode estar relacionada ao volume semanal de treino, aos desvios posturais em membros inferiores, ao tipo de calçado e ao piso selecionados para a prática da corrida, e até mesmo à experiência prévia na modalidade. A superfície de corrida pode ser considerada como um fator extrínseco relacionado a estas lesões e tem sido pesquisada atualmente mas com resultados controversos ainda quanto a sua influência nas sobrecargas do aparelho locomotor. Já, o tempo de experiência na corrida também pode ser considerado um importante fator extrínseco que foi até agora superficialmente estudado. O objetivo do presente trabalho foi investigar a influência de quatro diferentes superfícies de corrida (asfalto, concreto, grama natural e borracha) e da experiência prévia na prática da corrida (até 2 anos, entre 2 e 5 anos e acima de 5 anos) na distribuição da pressão plantar. Foram realizados 3 experimentos para responder aos objetivos do presente trabalho, cada um com sua casuística particular: experimento 1 (n=44) e 2 (n=57) para responder a influência do tipo de piso nas cargas plantares; e experimento 3 (n=126) para responder a influência da experiência da corrida nas pressões plantares. Em todos eles, corredores recreacionais adultos (entre 18 e 40 anos) correram nos 4 pisos estudados a uma velocidade de 12km/h em um trecho de 40 metros onde se investigou a pressão plantar por meio de palmilhas capacitivas (Pedar X, Novel) colocadas dentro de um calçado esportivo padronizado. Para investigar o efeito da experiência na corrida, as medições foram realizadas somente no asfalto. Os dois primeiros experimentos responderam que a grama atenuou em até 16% o pico de pressão plantar nas regiões laterais comparada aos demais pisos, inclusive à borracha cujo comportamento foi similar ao do asfalto e do concreto, superfícies consideradas rígidas. Este resultado pode ser atribuído a estratégias de movimento mais flexíveis das extremidades distais, particularmente do complexo tornozelo/pé, na superfície mais complacente, o qual não foi observado nas superfícies mais rígidas (asfalto e concreto), assim como, surpreendentemente, no piso de borracha. O terceiro experimento respondeu que corredores com menos do que dois anos de experiência na corrida apresentam maiores picos de pressão de cerca de 10% em retropé e antepé em relação aos mais experientes (acima de 5 anos). A atenuação de cargas plantares observadas em corredores mais experientes pode estar relacionada à adoção de um padrão motor mais eficiente que resultaria em uma maior habilidade de acomodação da extremidade distal às cargas. Como conclusão, os resultados destes experimentos demonstram que tempos de prática menores que dois anos e correr no asfalto, concreto ou borracha promovem maiores sobrecargas plantares. A combinação tempo de experiência acima de 5 anos e correr na grama é a condição que mais promove atenuação de sobrecargas plantares / There has been an increase in the number of injuries proportional to the increase of the number of runner. This occurrence can be related to the weekly distance of trainings, lower extremities postural alignment, type of the selected footwear and the running, and the previous experience in running. The running surface can be considered as a extrinsic factor related to these injuries and has been currently studied. Although the results concerning its influence in the overloads of the locomotor system are controversial. The time of running experience can also be considered an important extrinsic factor that is still superficially studied so far. The objective of the present work was to investigate the influence of four different running surfaces (asphalt, concrete, natural gram and rubber) and of the previous running experience (up to 2 years, between 2 and 5 years and up to 5 years) in the plantar pressure distribution. Three experiments had been carried out to answer to the aims of the present work, each one with its particular casuistic: experiment 1 (n=44) and 2 (n=57) to answer the influence of the type of surface in plantar loads; and experiment 3 (n=126) to answer the influence of the running experience in the plantar pressures. Adults recreational runners (between 18 and 40 yrs old) run in the four studied surfaces over 40 meters in a speed of 12km/h where the plantar pressure was investigated by in-shoe capacitive insoles (Pedar X, Novel) placed inside an standardized sports footwear. To investigate the effect of the running experience, the measurements had only been carried out in asphalt. The two first experiments answered that the grass attenuated up to 16% the peak pressure in the lateral regions of the foot compared to the other surfaces, including the rubber whose behavior was similar to the asphalt and the concrete, considered rigid surfaces. This result can be attributed the more flexible movement strategies of the distal extremities, particularly of the foot/ankle complex, in the more compliant surface, which was not observed in the most rigid surfaces (asphalt and concrete), as well as, surprisingly, in the rubber surface. The third experiment answered that runners with less than two years of experience in the running practice presented greaters peak pressures of about 10% in the medial rearfoot and forefoot compared to the most experienced runners (up to 5 years). The plantar loads attenuation observed in the more experienced runners can be related to the adoption of a more efficient motor pattern that would result in a higher ability to accommodate loads in the lower extremity. In summary, the results of these experiments demonstrated that running practice experience of less than two years and running in asphalt, concrete or rubber promotes higher plantar loads. The combination time of experience up to 5 years and running in the grass is the condition that promotes more attenuation of plantar pressures
305

Distribuição das tensões promovidas por implantes cone Morse inseridos em diferentes níveis ósseos: análise fotoelástica e método dos elementos finitos / Stress distribution promoted by Morse taper connection implants inserted in different bone levels: photoelastic analysis and finite element method

Sizo, Sergio Rodrigues 10 April 2015 (has links)
Ainda não existe um consenso sobre o nível em que os implantes cone Morse devem ser inseridos em relação à crista ósse alveolar. A literatura mostra diversas pesquisas em animais e laboratoriais com implantes posicionados acima, abaixo ou ao nível da crista. Contudo, diferentes metodologias e técnicas dificultam a definição do melhor nível de localização. O presente trabalho optou por analisar qualitativa e quantitativamente por meio da fotoelasticidade e do método dos elementos finitos (MEF), implantes em diferentes níveis de inserção sob carga compressiva estática, visando elucidar esse tema. Quatro níveis foram simulados: 1 mm acima da crista (AC); ao nível da crista (AN); 1 mm abaixo da crista sem aposição óssea sobre a plataforma (AB-S); e 1 mm abaixo da crista com aposição óssea sobre a plataforma (AB-C). Os resultados fotoelásticos demonstraram maiores valores de ordem de franja na região apical e menores na região cervical, em todos os modelos, independente do tipo de carga. No MEF verificou-se que o aprofundamento do implante da posição AC para AB-S reduziu progressivamente as tensões de von Mises na região cortical independente do tipo de carga, respectivamente, 0,5595 - 0,3842 Mpa nas cargas cêntricas e 1,5261 - 0,9787 MPa nas excêntricas. Concluiuse que houve redução na concentração de tensões posicionado-se o implante abaixo do crista óssea e uma tendência de aumento de tensão nas amostras AB-C, provavelmente devido à tração do osso existente sobre a plataforma do implante. / There is still no consensus on the level that the Morse taper implants should be inserted in relation to the alveolar crestal bone. The literature shows several studies in animals and laboratory implant positioned above, at level or subcrestal. However, different methodologies and techniques make it difficult to define the best level of the implant. This study analyzes qualitatively and quantitatively by using photoelastic analysis and the finite element method (FEM), implants at different levels under static compressive load, to elucidate this issue. Four levels were simulated: 1 mm above the crest (AC); the crest level (AN); 1 mm below the crest free bone apposition on the platform (AB-S); and 1 mm below the crest with bone apposition on the platform (ABC). Photoelastic results demonstrated higher fringe order of values in the apical region and lower in the cervical region, in all models, regardless of the loading type. In MEF found that the deepening of the implant position from AC to AB-S progressively reduced von Mises equivalent stresses in cortical region independent of the load type, respectively, 0.5595 - 0.3842 MPa in centric loads and 1.5261 - 0.9787 MPa in eccentric loads. It was concluded that there was a reduction in stress concentration on the implant positioned below the alveolar crest and a tendency of an increase in tension in the AB-C samples, probably due to traction on the existing bone implant platform.
306

Avaliação in vitro do colar de implantes cone Morse de diferentes diâmetros sob cargas cêntrica e excêntrica: estudo por meio da Interferometria Eletrônica por Padrões de Speckle / In vitro evaluation of the collar of Morse taper dental implants with different diameters under centric and eccentric loads: an electronic speckle pattern interferometry study

Sizo, Sergio Rodrigues 15 September 2011 (has links)
Cargas oclusais excessivas podem promover tensões exageradas às estruturas de implantes/pilares/próteses, resultando em deformação, desadaptação ou mesmo fratura dos componentes e do próprio implante. Além disso, tais sobrecargas podem gerar necrose por compressão e perda óssea peri-implantar e, ainda, a ocorrência de microdeslocamentos na interface de conexão implante-pilar (I-P) ocasionando a formação de fendas propícias à colonização bacteriana, o que pode levar ao desenvolvimento de peri-implantite, contribuindo para o insucesso do conjunto. O presente estudo objetivou avaliar, por meio de uma técnica já amplamente utilizada na Engenharia e na Física a Interferometria Eletrônica por Padrões de Speckle (ESPI) as deformações a nível do colar de implantes com conexão cônica interna (cone Morse) de diferentes diâmetros (Kopp 4,3/5,5 mm e Neodent 3,5/5,0 mm), sob dois tipos (cêntrica e excêntrica) e intensidades (50 N e 100 N) de cargas, similares as quais os implantes ficam expostos durante a função mastigatória. Testou-se a hipótese de que a deformação do colar do implante seria inversamente proporcional ao diâmetro do implante. Além disso, discutiu-se vantagens e limitações da técnica ESPI frente a outros métodos comumente utilizados na avaliação de tensões. As maiores deformações foram sempre associadas às cargas excêntricas, com exceção do G1-Kopp. A maior deformação ocorreu no G1-Neodent sob carga excêntrica de 100 N e a menor, no G2-Neodent sob carga cêntrica de 50 N. A técnica ESPI mostrou-se altamente sensível e reprodutível para avaliar deformações a nivel do colar de implantes sendo possível confirmar a hipótese inicial, visto que a maior deformação esteve sempre associada aos implantes de menor diâmetro, em ambos os sistemas de implante pesquisados. / Occlusal overloading may promote excessive stresses to the implants/abutments/prosthesis, resulting in deformation, misfit or fracture of the components, until the implants. Futhermore, strains of the implant-abutment connection can cause the formation of microgaps propitious to bacterial colonization, which leads to the development of peri-implant sites, leading to the failure of the rehabilitation. This study aimed to evaluate, by a technique widely used in the engineering and physics Electronic Speckle Pattern Interferometry (ESPI) the strains related to the implant collar with internal tappered connection (Morse taper) with different diameters (Kopp 4.3/5.5 mm and Neodent 3,5/5,0 mm), under two types (centric and eccentric) and intensities (50 N and 100 N) of loads, similar which implants are exposed during masticatory function. We tested the hypothesis that the strains of the implants collar would be inversely proportional to the diameter of the implant. In addition, the survey discussed the advantages and limitations of the ESPI technique over other methods commonly used to assess strains. The largest strain was always associated with eccentric loads, except for G1-Kopp. The largest strain occurred in the G1-Neodent under the eccentric loads of 100 N and the lowest in the G2-Neodent under the centric loads of 50 N. The ESPI technique was a highly sensitive and reproducible to evaluate the strains at the level of the collar of implants being possible to confirm the initial hypothesis, since most strains was always associated with narrower-diameter implants in both implant systems studied.
307

Desempenho de almofadas de argamassa modificada na transferência de tensões de compressão em ligações de concreto pré-moldado / Performance of modified mortar pads in the compression stresses transfer in precast concrete connections

Ditz, Jackson Deliz 23 April 2015 (has links)
Esta pesquisa visa analisar a transferência de tensões de compressão entre elementos de concreto pré-moldado através de almofadas de argamassa modificada. A argamassa foi modificada com as adições de fibras de polipropileno, látex estireno-butadieno e vermiculita termo-expandida. A caracterização da argamassa foi realizada com ensaios de compressão, de tração por compressão diametral e de módulo de elasticidade, além de ensaios de rigidez de almofada, que medem a capacidade da peça de se deformar sob tensão de compressão uniforme. As análises de transferência de tensões foram realizadas intercalando uma almofada entre dois blocos de concreto e submetendo o corpo de prova formado a ensaios de compressão. Os parâmetros variados nesses ensaios foram: rugosidade superficial e resistência mecânica dos blocos ligados, excentricidade de carregamento, solidarização ou não da almofada ao bloco inferior de concreto e carregamento monotônico e cíclico. Em relação à massa do cimento, a argamassa das almofadas possuía 30% de agregados, dos quais 95% eram areia fina e 5% eram vermiculita, 10% de látex, 2% de taxa volumétrica de fibras de polipropileno e relação água / cimento de 0,25, além da água incorporada no látex. A argamassa apresentou resistência à compressão média de 27,65 MPa, resistência à tração de 3,62 MPa e módulo de elasticidade igual a 11,53 GPa. Os principais resultados dos ensaios de ligação foram: a) para compressão centrada, a presença da almofada aumentou a resistência em 20% para espessuras de saliências de 0,5 mm e 30% para saliências de 1,0 mm; b) ganho de efetividade da almofada à medida que se reduziu a resistência do concreto; c) em ligações excêntricas, a dispersão dos resultados não permitiu uma correta avaliação dos resultados; d) para carregamento cíclico, a almofada de apoio aumentou em 45% a resistência da ligação. / This research aims to analyze the compressive stresses transfer between precast concrete elements by modified mortar pads. The mortar was modified with additions of polypropylene fibers, styrene-butadiene latex and heat-expanded vermiculite. Mortar characterization was performed in compression, tension and elastic modulus tests, further pad rigidity tests, that measure the pad capacity to deform under uniform compressive stress. Stress transfer analyzes were performed interleaving a bearing pad between two concrete blocks and subjecting the specimen formed in the compression tests. Varied parameters in these tests were: surface roughness and mechanical strength of the connected blocks, loading eccentricity, solidarization or not of the bearing pad to the bottom concrete block and monotonic and cyclic loading. In relation to the cement weight, the mortar of the pads showed 30% of aggregates, which 95% were fine sand and 5% were vermiculite, 10% of latex, 2% of volumetric rate of polypropylene fibers and water / cement ratio of 0,25, in addition of water incorporated into the latex. The mortar showed compression strength of 27,65 MPa, tension strength of 3,62 MPa and elastic modulus equal to 11,53 GPa. The main results of connection test were: a) for centered compression, presence of pad increased the strength in 20% for thicknesses of imperfections of 0,5 mm and 30% for imperfections of 1,0 mm; b) gain of effectiveness of the bearing pad when the concrete strength was reduced; c) in eccentrical connections, the dispersion of results did not allowed a correct evaluation of results; d) for cyclic loading, the bearing pad increased in 45% the connections strength.
308

Avaliação de cimentos de ionômero de vidro modificados por resina frente à incorporação de nanopartículas de vitrocerâmica bioativa / Resin modified glass ionomer cements evaluation with additional bioactive glass-ceramics nanoparticles

Freitas, Maria Cristina Carvalho de Almendra 31 May 2011 (has links)
Os materiais bioativos são materiais sintéticos que possuem superfícies ativas em que os minerais presentes em tecidos duros podem se ligar quimicamente. Há alguns estudos em Odontologia, onde partículas desses materiais foram incorporadas aos Cimentos de Ionômero de Vidro (CIVs) e Cimentos de Ionômero de Vidro modificados por resina (CIVMRs) com o objetivo de se obter bioatividade, e conseqüente remineralização dentária. O presente estudo teve como objetivo avaliar os efeitos da incorporação de nanopartículas de vitrocerâmica bioativa nas propriedades de resistência à compressão e rugosidade de CIVMRs. Fuji II LC e Vitremer foram considerados os grupos controles. Materiais experimentais foram feitos através da incorporação de 2, 5 e 10% em peso de Biosilicato nestes CIVMRs. Seis corpos-de-prova de cada material foram confeccionados para o teste de resistência à compressão, que foi realizado em máquina de ensaios universal (Emic), a uma velocidade de 1,0 mm/min, depois de mantidos por 24 horas em água destilada a 37°C. Para análise da rugosidade, foram confeccionados dois corpos-de-prova de cada material, armazenados em água destilada por sete dias, para terem suas superfícies analisadas por meio de Microscopia de Força Atômica. Os dados da resistência à compressão e rugosidade foram submetidos à análise estatística por meio da Análise de Variância (ANOVA) a dois critérios e para comparações múltiplas foi aplicado o teste de Tukey, com nível de significância de 5%. Apenas os cimentos com 2% de nanopartículas de vitrocerâmica bioativa obtiveram resistência à compressão semelhante ao grupo controle, as demais concentrações contribuíram para a diminuição dessa resistência. A incorporação de 5% de nanopartículas de vitrocerâmica bioativa aumentou a rugosidade superficial dos CIVMRs estudados. / Bioactive materials are synthetic materials that have active surfaces that are capable to chemically bond to dental structures. There are some studies where particles of these materials were incorporated in Glass-ionomer cements (GIC) and Resin-modified glass-ionomer cements (RMGIC) trying to achieve bioactivity and dental remineralization. The aim of this study was to evaluate the effects of the incorporation of bioactive glass-ceramics nanoparticles on the compressive strength and roughness of RMGIC. Fuji II LC and Vitremer were considered the control groups. Experimental materials were made adding 2, 5 and 10% (weight) of Biosilicate into these RMGIC. Six specimens of each material were made to be tested on compressive strength performed with a universal testing machine (Emic) at a crosshead speed of 1.0 mm / min, after they were stored in distilled water for 24 hour at 37°C. To roughness analysis, two specimens of each material were made and stored in distilled water for 7 days and their surfaces were analyzed with a Atomic Force Microscope. Data of compressive strength and roughness were statistically analyzed by ANOVA and Tukey test for multiple comparisons. Only the RMGICs with 2% of bioactive glass-ceramic nanoparticles obtained compressive strength similar to the control RMGICs, the other concentrations decreased their compressive strength values. The incorporation of 5% of bioactive glass-ceramic nanoparticles increased the roughness of the RMGICs.
309

Distribuição dinâmica de sobrecargas no pé durante a corrida em diferentes pisos / In-shoe dynamic foot loading during running in different running surfaces

Vitor Daniel Tessutti 15 December 2008 (has links)
Associado ao aumento do número de praticantes de corrida, houve o aumento proporcional no número de lesões em corredores. Esta ocorrência pode estar relacionada ao volume semanal de treino, aos desvios posturais em membros inferiores, ao tipo de calçado e ao piso selecionados para a prática da corrida, e até mesmo à experiência prévia na modalidade. A superfície de corrida pode ser considerada como um fator extrínseco relacionado a estas lesões e tem sido pesquisada atualmente mas com resultados controversos ainda quanto a sua influência nas sobrecargas do aparelho locomotor. Já, o tempo de experiência na corrida também pode ser considerado um importante fator extrínseco que foi até agora superficialmente estudado. O objetivo do presente trabalho foi investigar a influência de quatro diferentes superfícies de corrida (asfalto, concreto, grama natural e borracha) e da experiência prévia na prática da corrida (até 2 anos, entre 2 e 5 anos e acima de 5 anos) na distribuição da pressão plantar. Foram realizados 3 experimentos para responder aos objetivos do presente trabalho, cada um com sua casuística particular: experimento 1 (n=44) e 2 (n=57) para responder a influência do tipo de piso nas cargas plantares; e experimento 3 (n=126) para responder a influência da experiência da corrida nas pressões plantares. Em todos eles, corredores recreacionais adultos (entre 18 e 40 anos) correram nos 4 pisos estudados a uma velocidade de 12km/h em um trecho de 40 metros onde se investigou a pressão plantar por meio de palmilhas capacitivas (Pedar X, Novel) colocadas dentro de um calçado esportivo padronizado. Para investigar o efeito da experiência na corrida, as medições foram realizadas somente no asfalto. Os dois primeiros experimentos responderam que a grama atenuou em até 16% o pico de pressão plantar nas regiões laterais comparada aos demais pisos, inclusive à borracha cujo comportamento foi similar ao do asfalto e do concreto, superfícies consideradas rígidas. Este resultado pode ser atribuído a estratégias de movimento mais flexíveis das extremidades distais, particularmente do complexo tornozelo/pé, na superfície mais complacente, o qual não foi observado nas superfícies mais rígidas (asfalto e concreto), assim como, surpreendentemente, no piso de borracha. O terceiro experimento respondeu que corredores com menos do que dois anos de experiência na corrida apresentam maiores picos de pressão de cerca de 10% em retropé e antepé em relação aos mais experientes (acima de 5 anos). A atenuação de cargas plantares observadas em corredores mais experientes pode estar relacionada à adoção de um padrão motor mais eficiente que resultaria em uma maior habilidade de acomodação da extremidade distal às cargas. Como conclusão, os resultados destes experimentos demonstram que tempos de prática menores que dois anos e correr no asfalto, concreto ou borracha promovem maiores sobrecargas plantares. A combinação tempo de experiência acima de 5 anos e correr na grama é a condição que mais promove atenuação de sobrecargas plantares / There has been an increase in the number of injuries proportional to the increase of the number of runner. This occurrence can be related to the weekly distance of trainings, lower extremities postural alignment, type of the selected footwear and the running, and the previous experience in running. The running surface can be considered as a extrinsic factor related to these injuries and has been currently studied. Although the results concerning its influence in the overloads of the locomotor system are controversial. The time of running experience can also be considered an important extrinsic factor that is still superficially studied so far. The objective of the present work was to investigate the influence of four different running surfaces (asphalt, concrete, natural gram and rubber) and of the previous running experience (up to 2 years, between 2 and 5 years and up to 5 years) in the plantar pressure distribution. Three experiments had been carried out to answer to the aims of the present work, each one with its particular casuistic: experiment 1 (n=44) and 2 (n=57) to answer the influence of the type of surface in plantar loads; and experiment 3 (n=126) to answer the influence of the running experience in the plantar pressures. Adults recreational runners (between 18 and 40 yrs old) run in the four studied surfaces over 40 meters in a speed of 12km/h where the plantar pressure was investigated by in-shoe capacitive insoles (Pedar X, Novel) placed inside an standardized sports footwear. To investigate the effect of the running experience, the measurements had only been carried out in asphalt. The two first experiments answered that the grass attenuated up to 16% the peak pressure in the lateral regions of the foot compared to the other surfaces, including the rubber whose behavior was similar to the asphalt and the concrete, considered rigid surfaces. This result can be attributed the more flexible movement strategies of the distal extremities, particularly of the foot/ankle complex, in the more compliant surface, which was not observed in the most rigid surfaces (asphalt and concrete), as well as, surprisingly, in the rubber surface. The third experiment answered that runners with less than two years of experience in the running practice presented greaters peak pressures of about 10% in the medial rearfoot and forefoot compared to the most experienced runners (up to 5 years). The plantar loads attenuation observed in the more experienced runners can be related to the adoption of a more efficient motor pattern that would result in a higher ability to accommodate loads in the lower extremity. In summary, the results of these experiments demonstrated that running practice experience of less than two years and running in asphalt, concrete or rubber promotes higher plantar loads. The combination time of experience up to 5 years and running in the grass is the condition that promotes more attenuation of plantar pressures
310

Contribuições à modelagem numérica de alvenaria estrutural / Contributions to the numerical analysis of masonry

Peleteiro, Suzana Campana 01 April 2002 (has links)
Uma das áreas da engenharia civil que têm apresentado maior potencial de crescimento é a execução de edifícios em alvenaria estrutural. Usualmente são utilizados procedimentos puramente experimentais para o desenvolvimento dos processos construtivos e de projeto. Entretanto, a experimentação sem uma modelagem teórica prévia pode ser muito dispendiosa. A modelagem numérica, desde que confiável, pode ser de grande ajuda na redução do número de corpos-de-prova a serem ensaiados e do número de pontos a serem instrumentados, bem como o seu devido posicionamento. Isso significa diminuição de custos e maior eficiência na obtenção de resultados. No presente trabalho apresentam-se as ferramentas computacionais mais adequadas para a análise de alvenaria estrutural submetida a compressão, objetivando o suporte teórico a pesquisas experimentais. Elabora-se um estudo comparativo sobre os vários recursos de modelagem numérica, linear e não-linear, disponíveis em softwares comerciais baseados no método dos elementos finitos. Inicialmente, após a apresentação do estado da arte, investiga-se a modelagem numérica do volume elementar representativo da alvenaria. Modelos não-lineares são, então, escolhidos, aferindo-os com resultados disponíveis na literatura técnica. São realizadas simulações de casos específicos de paredes de alvenaria submetidas à compressão, assim como a interação de paredes sujeitas a carregamentos verticais. Resultados experimentais são comparados com os produzidos por modelos lineares e não-lineares, focando a análise na sua representatividade e no seu grau de precisão / The construction of structural masonry buildings has been one of the most increasing civil engineering areas. The development of building and design methods usually is based only on experiments. However, testing without previous numerical analysis can be very expensive. Numerical modeling, since reliable, can be greatly helpful for reducing the number of experimental tests and the number of instrumented points, including the improvement of their positions. That enables smaller costs and higher efficiency in obtaining the results. The present work deals with the most appropriate computational strategies for the analysis of masonry walls subjected to compression, focusing the theoretical support for experimental research programs. A comparative study is elaborated on the several capabilities of linear and nonlinear numerical models, which are available in commercial computer programs based on the finite element method. Initially, after the presentation of the state-of-the-art, the numerical analysis of the representative volume masonry element is investigated. Nonlinear models are chosen and confronted with available results in the technical literature. Specific cases of masonry walls submitted to compression are numerical simulated, including the interaction of intersecting walls under vertical loads. Experimental results are compared to those produced by linear and nonlinear numerical modeling, emphasizing their effectiveness and precision

Page generated in 0.073 seconds