• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 325
  • 65
  • 14
  • 14
  • 12
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 489
  • 489
  • 432
  • 389
  • 314
  • 310
  • 280
  • 279
  • 64
  • 63
  • 62
  • 57
  • 54
  • 53
  • 52
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Efeitos da terapia laser de baixa potência na estabilidade e no deslocamento de mini-implantes ortodônticos submetidos a carga / Effect of low-level laser therapy on stability and displacement of orthodontic mini-implants submitted to loading

Vásquez, Guido Artemio Marañón 26 April 2018 (has links)
O presente estudo teve o objetivo de avaliar o efeito da Terapia Laser de Baixa Potência (TLBP) na estabilidade e no deslocamento de mini-implantes (MIs) submetidos a carga. A hipótese nula testada foi que a irradiação laser e o tipo de carga aplicada (imediata ou mediata) não influenciam na estabilidade e no deslocamento de MIs. Foram avaliados 48 dispositivos para a estabilidade e 35 para o deslocamento, os quais foram implantados em pacientes da clínica de pós graduação em Ortodontia da Faculdade de Odontologia de Ribeirão Preto da Universidade de São Paulo. Os MIs foram divididos em 4 grupos segundo a intervenção recebida: 1- TLBP + CI (carga imediata), 2- TLBP + CM (carga mediata / após 4 semanas da implantação), 3- CI (sem TLBP) e 4- CM (após 4 semanas da implantação / sem TLBP). Carga de 150 gF foi aplicada por período de 3 meses para todos os dispositivos. A TLBP foi aplicada usando emissão laser vermelha com comprimento de onda de 660 nm e potência de 100 mW, imediatamente após implantação (densidade de energia: 4 J/cm&sup2; ). Nos dias posteriores foram aplicadas emissões laser infravermelhas com comprimento de onda de 808 nm a cada 48 horas durante duas semanas após colocação dos dispositivos (densidade de energia: 8 J/cm&sup2; para cada aplicação). A estabilidade dos dispositivos foi avaliada pela Análise de Freqüência de Ressonância (AFR) em três momentos: T0 no dia da implantação; T1 antes da aplicação da carga, somente nos grupos 2 e 4; e T2 após três meses de aplicação de carga. Para a avaliação do deslocamento dos dispositivos foram utilizadas imagens de Tomografias Computadorizadas de Feixe Cônico (TCFC). Planos tridimensionais foram criados a partir de pontos de referência identificados na maxila e mandibula para medir e comparar as diferenças entre as distâncias inicial (TC0) e final (TC1) da cabeça do MI ao plano tridimensional. Os resultados demonstraram que o grupo 2 apresentou a menor perda de estabilidade de todos os grupos (p= 0.0161). Os dispositivos que receberam TLBP (Grupos 1 e 2) apresentaram menor perda de estabilidade quando comparados aos grupos que não receberam irradiação laser (p= 0.0372). Os MIs que receberam CI (Grupos 1 e 3) apresentaram maior perda de estabilidade quando foi avaliado o tempo efetivo de aplicação da carga (p< 0.0001). Todos os dispositivos apresentaram deslocamento sem diferenças estatisticamente significantes entre os grupos. A hipótese nula foi parcialmente rejeitada. Os MIs que receberam TLBP e CM tiveram menor perda de estabilidade. O deslocamento não foi influenciado pela irradiação laser e pelo protocolo de aplicação da carga / The present study aimed to evaluate the effect of Low-level Laser Therapy (LLLT) on stability and displacement of mini-implants (MIs) submitted to loading. The null hypothesis tested was that laser irradiation and the applied loading protocol (immediate or mediate) do not influence the stability and displacement of MIs. Forty-eight devices were assessed for stability and 35 for displacement. They were implanted in patients from the graduate clinic of Orthodontics of the School of Dentistry of Ribeirão Preto, University of São Paulo. MIs were divided in four groups according to received intervention: 1- LLLT + IL (immediate loading), 2- LLLT + ML (mediate loading / 4 weeks after implantation), 3- IL (without LLLT) and 4- ML (4 weeks after implantation / without LLLT). Loading of 150 gF was applied during 3 months for all devices. LLLT was implemented using red laser emission with wavelength of 660 nm and potency of 100 mW, immediately after implantation (energy density: 4 J/cm2). In the later days they were applied infrared laser emissions with wavelength of 808 nm every 48 hours during two weeks after placement of devices (energy density: 8 J/cm2 for each application). MIs stability assessment was performed by Resonance Frequency Analysis (RFA) at three moments: T0 on the day of implantation; T1 before loading, for groups 2 and 4; and, T2 after three months of loading application. For displacement analysis, images from Cone-beam Computed Tomography (CBCT) scans were used. Threedimensional planes were created based on landmarks identified on maxilla and mandible to measure and compare differences of initial (TC0) and final (TC1) distances from the MIs head to the plane. Results demonstrated that group 2 presented the lowest loss of stability of all groups (p= 0.0161). Devices that received LLLT (Groups 1 and 2) showed lower loss of stability when they were compared with the groups that did not receive LLLT (p= 0.0372). MIs that received IL (Groups 1 and 3) presented greater loss of stability when the effective time of loading application was assessed (p< 0.0001). All groups showed displacement of the devices without significant differences between them. The null hypothesis was partially rejected. MIs that received LLLT and ML had lower loss of stability. Displacement was not influenced by laser irradiation or loading protocol
322

Algoritmo para interpretação das alterações ósseas pela imaginologia odontológica / Algorithm for interpretation of bone changes by dental Imaging

Santos, Elza Maria Carneiro Mendes Ferreira dos 17 May 2018 (has links)
O objetivo deste estudo foi de elaborar uma metodologia a ser utilizada no exame por imagem com o propósito da criação de um aplicativo digital para auxílio na identificação da entidade envolvida nas alterações ósseas pela imaginologia odontológica. O algoritmo criado, permitiu orientar o diagnóstico por imagem por meio de do exame por imagem. Foi padronizado da seguinte forma: 1) criação de um banco de dados, o qual foi constituído por meio das características radiográficas em de 19 (dezenove) lesões ósseas: Ameloblastoma, Cementoblastoma, Cisto de Stafne, Cisto Dentígero, Cisto Nasopalatino, Cisto Ósseo Simples, Cisto inflamatório Colateral, Cisto Radicular, Fibroma Ameloblástico, Granuloma Central De Células Gigantes, Mixofibroma Odontogênico, Odontoma Composto, Odontoma Complexo, Queratocisto Odontogênico, Tumor Odontogênico Adenomatóide, Tumor Odontogênico Epitelial Calcificante, Fibroma Ossificante Central, Displasia Cementária Periapical e Displasia Cemento Ósseo Florida, descritas pelos autores Langlais (1), White (2), Whaites (3), Sapp (4), Haiter Neto (5) e Watanabe(6). Pode se concluir que foi possível assegurar da validade da metodologia, estabelecendo assim a sistematização dos dados e por consequente a elaboração do algoritmo. / The objective of this study was to elaborate a methodology to be used in the imaging exam with the purpose of creating a digital application to aid in the identification of the entity involved in bone alterations by dental imaging. The algorithm created allowed to guide the diagnosis by image through the imaging examination. It was standardized as follows: 1) creation of a database, which was constituted by means of radiographic characteristics in 19 (nineteen) pathologies: Ameloblastoma, Cementoblastoma, Stafne\'s Cyst, Dentigerous Cyst, Nasopalatine Cyst, Simple Bone Cyst, Adenomatoid Odontogenic Tumor, Calcifying Epithelial Odontogenic Tumor, Central Ossific Fibroma, Periapical Cement Dysplasia, and Dysplasia Bone Cement, Florida, Florida, United States of America Cystic Fibrosis, Cystic Fibroma, Dysplasia, Cystic Fibrosis, described by the authors Langlais (1), White (2), Whaites (3), Sapp (4), Haiter Neto (5) and Watanabe (6). 2) for each pathology, a spreadsheet containing the respective radiographic descriptions of the bone alterations found and described by each one of the mentioned authors was elaborated; 3) in front of the information the contents were organized, through different tests of combinations of the criteria and respective characteristics, using an application prototype. It can be concluded that it was possible to assure the validity of the methodology, thus establishing the systematization of the data and consequently the elaboration of the algorithm.
323

Avaliação em 3D da cabeça da mandíbula em crianças portadoras de mordida cruzada posterior unilateral por meio de tomografia computadorizada de feixe cônico / 3D evaluation of the condyle in children with unilateral posterior cross bite using Cone Beam Computed Tomography

Illipronti Filho, Edson 20 January 2016 (has links)
Durante o desenvolvimento da oclusão, a instalação de maloclusões podem resultar em desarmonias dento faciais de natureza e severidade diversas, podendo provocar alterações no desenvolvimento crânio facial, dentre as estruturas envolvidas as Articulações Temporo Mandibulares (ATM), podem sofrer alguma influência, dessa forma a avaliação desta região, no aspecto morfológico e funcional, constituí tema de interesse, sempre que levados em conta os aspectos funcionais da oclusão. A relação entre a forma e a função, tanto das cabeças da mandíbula, bem como o contorno da fossa mandibular com as maloclusões ainda é controversa e não está compreendida por completo, porém a literatura sobre o assunto, demonstra correlação entre a instalação de maloclusões e modificações neste sistema, mesmo que algumas alterações não sejam de ordem estatística e em amostras de indivíduos em tenra idade, as mesmas podem comprometer o desenvolvimento adequado em indivíduos adultos ou mesmo adultos jovens. Tendo como propósito nesse estudo a avaliação das cabeças da mandíbula quanto ao volume e superficíe dos lados direito e esquerdo, cruzado e não cruzado, a amostra selecionada foi de 20 indivíduos com mordida cruzada posterior unilateral, com idades entre 06 e 09 anos de idade, utilizando imagens de tomografia computadorizada por feixe cônico, imagens obtidas por um equipamento modelo i- Cat, sendo utilizado na reformatação e manipulação das imagens o programa computacional - NemoCeph 3D® versão 11.5. Nas medições propostas para esse estudo, utilizou-se o teste t pareado de Student para amostras com distribuição normal. Na observação das tabelas e seus respectivos gráficos, podemos verificar que na comparação entre os lados direito e esquerdo, e cruzado e não cruzado das cabeças da mandíbula, com relação ao volume e superfície, existem diferenças numéricas entre elas, porém não pode ser observado diferenças estatísticas significantes, nessa amostra especifica com a metodologia empregada para esse estudo. Assim foi possível concluir que nas Mordidas Cruzadas Posteriores Unilaterais as cabeças da mandíbula tanto em seu volume como em sua superfície não apresentaram diferenças estatisticamente significantes na amostra estudada. / During the development of occlusion, malocclusions installation may result in disharmony dento facial nature and various severity, can cause changes in craniofacial development, among the structures involved in the temporomandibular joints mandibular (ATM), may suffer some influence, thus the evaluation of this region, the morphological and functional aspect, constitutes topic of interest, when taken into account the functional aspects of occlusion. The relationship between form and function, both the heads of the jaw, as well as the outline of the mandibular fossa with malocclusion remains controversial and is not fully understood, but the literature on the subject shows correlation between the installation of malocclusions and modifications to this system, even if some changes are not of statistical order and samples from individuals at an early age, they can compromise the proper development in adults and even young adults. With the intent of this study was to evaluate the heads of the jaw as the volume and surface of the right and left sides, crossed and uncrossed, the selected sample of 20 subjects with unilateral posterior cross bite, aged from 06 to 09 years old, using computed tomography cone beam, images obtained by a device model i-Cat, being used in reformatting and manipulation of images the computer program - NemoCeph 3D® version 11.5. The proposals measurements for this study, we used the paired t-test of Student for samples with normal distribution. The observation of the tables and their graphs, we can see that the comparison between the right and left sides, and crossed and uncrossed the heads of the mandible in relation to the volume and surface, there are numerical differences between them, but can not be observed differences statistically significant, this sample specifies the methodology used for this study. Thus it was concluded that the Unilateral Posterior Crossbites the heads of the jaw in both its volume and its surface showed no statistically significant differences
324

Método de cálculo volumétrico de seios maxilares por meio de tomografia computadorizada por feixe cônico e software para edição de imagens visando planejamento cirúrgico de elevação do assoalho do seio maxilar / Method for the measurement of maxillary sinus volume using cone beam computed tomography and image editor software for planning maxillary sinus floor elevation surgery

Kanaji, Jorge Fumio 14 September 2009 (has links)
Objetivo: Validar a proposta de cálculo do volume de seios maxilares, utilizando-se de imagens trans-axiais geradas por meio de tomografia computadorizada por feixe cônico, analisando as mesmas em software para edição de imagens, e comparando os volumes aferidos, com os obtidos por meio de molde dos seios maxilares com silicone de condensação fluido. Métodos: Foram utilizados 05 crânios secos com osteotomia axial, pertencentes ao acervo do Laboratório de Anatomia da Universidade Cidade de São Paulo, de modo que se pudesse observar os seios maxilares em vista superior, totalizando 6 sítios. Os sítios foram moldados com silicone de condensação flúido por meio da injeção do mesmo com uma seringa para elastômero, e modelos dos seios maxilares foram confeccionados por meio da imersão dos moldes de silicone em gesso. Os modelos de gesso foram hidratados e preenchidos com água até que se atingisse a altura de 10mm e esse volume de água foi removido por meio de uma pipeta graduada na qual pôde-se fazer a leitura do volume. A amostra foi então submetida a tomografia computadorizada por feixe cônico, para posterior reformatação em cortes trans-axiais, que foram analisados no software Photoshop CS3 Extended® e o cálculo do volume foi feito com auxílio do software Excel®. Resultados: Os dados obtidos pelos dois métodos foram comparados estatisticamente por meio de gráficos de perfis individuais, diagrama de dispersão (Bussab e Morettin), coeficiente de correlação intraclasse (Fleiss) e gráfico de Bland-Altman. Após análise dos métodos estatísticos se observou reprodutibilidade de ambos os métodos e forte correlação entre os mesmos. Conclusão: Os cortes trans-axiais da maxila, obtidos por meio da tomografia computadorizada por feixe cônico, podem ser utilizados para cálculo dos volumes de seios maxilares, quando da análise dos mesmos em software Photoshop CS3 Extended®, fornecendo valores de volume próximos e estatisticamente compatíveis aos obtidos por meio do molde dos seios maxilares com silicone de condensação (padrão ouro), de maneira sistematizada e de fácil reprodução. / Purpose: To validate the proposal for measurement of maxillary sinus volume, using cross-sectional images generated by cone beam computed tomography, which were analyzed with an image editor software, and comparing the estimated volumes with those obtained through impression with fluid condensation silicone. Methods: Five dry skulls axially osteotomized, from the São Paulo University City Anatomy Laboratory, were used to allow an upper view of the maxillary sinuses, totaling 6 sites. The sites were molded com fluid condensation silicone injected with an elastomer syringe, and maxillary sinus models were produced by immersing the silicone mold into plaster. The plaster casts were hydrated and fulfilled with water reaching 10 mm height, which was removed with a graduated pipette to determine the water volume. The sample underwent cone beam computed tomography and the images were reformatted to produce cross-sectional views, which were analyzed with Photoshop CS3 Extended®, and the volume was calculated using Excel®. Results: Data obtained by both methods were statistically compared based on individual profile graphic, dispersion diagram (Bussab and Morettin), intraclass correlation coefficient (Fleiss) and Bland-Altman plot. After being analyzed, the two statistical methods showed reproducibility and strong correlation. Conclusion: Cross-sectional views generated by cone beam computed tomography and analyzed with Photoshop CS3 Extended® are useful to calculate the maxillary sinus volume, in order to help in planning the maxillary sinus floor elevation surgery.
325

Estudo do osso zigomático em tomografia computadorizada de feixe cônico / Study of the zygomatic bone in cone-beam computed tomography

Del Neri, Nathalia Bigelli 01 July 2011 (has links)
O aumento da procura pela reabilitação de rebordos desdentados com cirurgias reconstrutivas e implantes osseointegráveis, faz com que se torne necessário um estudo mais detalhado das características anatômicas dos ossos maxilares e suas possíveis variações. Neste contexto, a fixação zigomática é uma alternativa aos enxertos ósseos para a reabilitação de rebordos maxilares atróficos, onde altura e largura da crista óssea insuficientes impedem a instalação de implantes convencionais. As variações da anatomia do osso zigomático indicam a necessidade de um planejamento tridimensional. O exame por tomografia computadorizada de feixe-cônico (TCFC) se mostra adequado para exame das estruturas ósseas maxilofaciais e ainda apresenta vantagens como baixo custo e menor dose de radiação quando comparada à tomografia computadorizada helicoidal. Este estudo, composto de duas amostras independentes, se propôs a avaliar aspectos relacionados à anatomia do osso zigomático (OZ) e, mais especificamente, o forame zigomático-facial (FZF), em pacientes e em crânios macerados. Em um primeiro momento, foram avaliadas, retrospectivamente, imagens de TCFC de 40 pacientes (80 ossos zigomáticos), obtidas pelo aparelho i-CAT Classic®. Foram observados a presença e número do FZF, quando presente; avaliada a espessura média do OZ e delimitada uma região no osso zigomático a partir de pontos antropométricos Jugale (Ju) e Zigomaxilare (Zm), para dimensionar o local de inserção de implantes zigomáticos, em valores de área e volume. A incidência de um único forame foi observada em 40% dos ossos zigomáticos (n=32), dois forames em 20% (n=16), e três em 3,75% dos OZs (n=3). Em 36,25% dos ossos zigomáticos (n=29), o forame estava ausente. A espessura média do OZ encontrada foi de 10,3mm, variando de 5,45mm a 16,8mm. A área e volume médios para instalação de implantes zigomáticos foi de 147,93mm2 e 1102,9 mm3, respectivamente. Em um segundo momento, foram estudados 151 crânios macerados, totalizando 302 ossos zigomáticos, quanto à presença e número do FZF, quando presente, e a incidência encontrada foi de um forame em 44% dos ossos zigomáticos (n=133), dois forames em 28% (n=86), e três em 8% dos OZ (n=24). Em 19% dos ossos zigomáticos (n=57), o forame estava ausente e em 2 casos apenas haviam quatro forames (1%). Destes 151 crânios, 20 foram selecionados aleatoriamente para mensuração do diâmetro desses FZF, e posteriormente os mesmos foram submetidos à TCFC para que se avaliasse a acurácia deste exame em mostrar esta estrutura anatômica (FZF). A média de diâmetro encontrada foi de 0,57mm (±0,27mm). Todos os forames, mesmo os de menor calibre puderam ser observados nos cortes tomográficos. Os resultados levam a concluir que o exame tridimensional do osso zigomático é de extrema importância quando se pretende intervir nesta região, dada a sua variabilidade anatômica, e que a tomografia computadorizada de feixe cônico se mostrou adequada para esta finalidade. / The increased demand for rehabilitation of edentulous ridges with reconstructive surgery and dental implants, does it become necessary a more detailed study of the anatomical features of the jaws and their possible variations. In this context, the zygomatic implants are an alternative to bone grafting in the rehabilitation of atrophic maxillary ridges, where insufficient height and width of the bony crest prevent the installation of conventional implants. The variation in the anatomy of the zygomatic bone indicates the need for a three-dimensional planning system. Examination by cone-beam computed tomography scan is more appropriate for a thorough examination of the maxilofacial structures and has advantages as low cost and less radiation dose compared with convencional computed tomography. This study, composed of two independent samples, aimed to evaluate aspects related to the anatomy of the zygomatic bone and more specifically, the zygomatic-facial foramen in patients and in macerated skulls. At first, were evaluated, retrospectively, the CBCT images of 40 patients (80 zygomatic bones), obtained by the apparatus i-CAT Classic®. Were observed the presence and number of ZFF, when present, evaluated the average thickness of ZB and mapped an area on the zygomatic bone from anthropometric points Jugale and Zigomaxilare to scale the approximate area of insertion of zygomatic implants, in area values and volume. The incidence of a single foramen was found in 40% of zygomatic bone (n = 32), two foramen in 20% (n = 16) and three at 3.75% ZB (n = 3). In 36.25% of the zygomatic bone (n = 29), the foramen was absent. The average thickness of ZB was found to be 10.3 mm, ranging from 5.45 mm to 16.8 mm. The average area and volume for installation of zygomatic implants was 147.93 mm2 mm3 and 1102.9, respectively. In a second step, were studied 151 macerated skulls, totaling 302 zygomatic bones regarding to the presence and number of ZFF were evaluated, when present, and the incidence found was a foramen in 44% of the zygomatic bone (n = 133), two foramina in 28 % (n = 86) and three in 8% of ZB (n = 24). In 19% of zygomatic bone (n = 57) the foramen was absent and in only 2 cases had four foramen (1%). Of these 151 skulls, 20 were randomly selected for measuring the diameter of ZFF, and later they were submitted to CBCT in order to assess the accuracy of this exame to show this anatomical structure (ZFF). The average diameter was found to be 0.57 mm (± 0.27 mm). All foramen, even with smaller diameters were observed in tomography slices. The results support a conclusion that the tridimensional exam of the zygomatic bone is extremely important when it intends to intervene in this region, in view of the anatomical variability, and that the CBCT is more suitable for this purpose.
326

Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribs

Pinheiro, Lucas Rodrigues 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
327

Avaliação da expansão de maxila cirurgicamente assistida (EMCA) por meio da tomografia computadorizada de feixe cônico / Evaluation of surgically assisted rapid maxillary expansion (SARME) using cone beam computed tomography

Salgueiro, Daniel Gomes 29 November 2013 (has links)
O objetivo deste estudo foi avaliar por meio da tomografia computadorizada de feixe cônico (TCFC) o padrão de abertura e o processo de neoformação óssea da sutura intermaxilar em pacientes submetidos à expansão de maxila cirurgicamente assistida (EMCA). Foram avaliados 14 indivíduos submetidos à expansão de maxila cirurgicamente assistida (EMCA) pela técnica da osteotomia Le Fort I subtotal utilizando tomografia computadorizada de feixe cônico (TCFC) nos períodos préoperatório e pós-operatório de 15, 60 e 180 dias. A partir da observação do padrão de abertura da sutura intermaxilar, após a cirurgia, pôde-se classificá-la nos tipos I e II. O Tipo I corresponde à abertura da sutura intermaxilar desde a espinha nasal anterior até a espinha nasal posterior, o Tipo II, à abertura desde a espinha nasal anterior até a sutura transversal palatina. Este padrão foi relacionado à técnica cirurgica, idade do paciente e tipo de aparelho expansor. As médias de densidade da óssea na região da sutura intermaxilar foram comparadas entre os períodos estudados (pré e pós-operatório de 15, 60 e 180 dias) para acompanhar a neoformação óssea. Os dados foram tabulados e submetidos à análise estatística. Os resultados mostraram a ocorrência do padrão de abertura tipo I em 12 indivíduos e o padrão tipo II em 2 indivíduos. A média de densidade óssea encontrada no período pós-operatório de 180 dias (PO 180) foi de 49,9% em relação a media do período pré-operatório (Pré). Concluiu-se que o padrão de abertura da sutura intermaxilar está mais relacionado à idade do paciente, que nesse estudo foi de 23,9 anos para o tipo I e 33,5 anos, para o tipo II, e à técnica cirúrgica empregada e que ao final do período de contenção estudado (PO 180) não foi possível observar a total neoformação óssea na região da sutura intermaxilar. / The aim of this study was to evaluate using cone beam computed tomography (CBCT) the opening pattern and process of bone formation in the intermaxillary suture in patients with transverse maxillary deficiency undergone surgically assisted rapid maxillary expansion (SARME). Fourteen patients were evaluated whom submitted to surgically assisted maxillary expansion (SARME) by the technique of subtotal Le Fort I osteotomy using beam computed tomography (CBCT) in the preoperative and postoperative periods of 15, 60 and 180 days. From the observation of the opening pattern of the intermaxillary suture, after surgery, were classifie in types I and II. Type I corresponds to the opening of the intermaxillary suture from the anterior nasal spine to posterior nasal spine, and Type II corresponds to opening from the anterior nasal spine to the transverse palatine suture. This pattern was related to surgical technique, patient age and type of expander device. The average density of the bone in the region of the intermaxillary suture were compared between the studied periods (pre-and postoperative 15, 60 and 180 days) to evaluate bone formation. Data were tabulated and analyzed statistically. The results showed the occurrence of the opening pattern type I in 12 subjects and the standard type II in 2 individuals. The mean value of density found in the postoperative period of 180 days (PO 180) was 49.9% compared to the mean of the preoperative (Pre). It was concluded that the pattern of opening the intermaxillary suture is related to patients age, that was 23,9 years in type I and 33,5 years in type II and the surgical technique, furthermore, at the end of the retention period studied (PO 180) was not possible to observe the complete bone formation in the region of the intermaxillary suture.
328

Avaliação da eficiência de sistemas rotatórios para desobturação em canais curvos, por meio de tomografia computadorizada por feixe cônico / Evaluation of the efficiency of rotary systems for remove filling materials in curved canals through cone beam computed tomography

Costa, Giovana Borba Gazzinelli 02 December 2013 (has links)
O presente estudo teve por objetivo avaliar ex vivo a eficiência de sistemas para retratamento (ProTaper Universal Retratamento, Mtwo Retratamento e D-Race), na desobturação de canais mésio vestibulares curvos de molares superiores, por meio de tomografia computadorizada por feixe cônico. Foram utilizados canais mésio vestibulares com curvatura entre 20° e 40°, de 36 molares superiores, preparados com Protaper Universal (até instrumento F2), obturados com cone ProTaper F2 e cimento AH Plus, pela técnica de condensação lateral. Para a desobturação, os dentes foram divididos em grupos (I: ProTaper Universal Retratamento, II: Mtwo Retratamento e III: D-Race). A captura das imagens foi realizada após a obturação e após a desobturação dos canais radiculares, por meio de tomografia computadorizada por feixe cônico de pequeno volume (Prexion 3D XTrillion Inc). As imagens foram segmentadas utilizando o programa InVesalius, para verificar o material obturador remanescente. O tempo para desobturação também foi analisado. De posse dos valores, iniciais e finais, de volume de material obturador e de estrutura dentinária, a proporção dos volumes foi calculada. Para a análise estatística, os resultados foram avaliados pelos testes de ANOVA e de Múltiplas Comparações de Bonferroni. Os grupos ProTaper Universal Retratamento (13,97%) e D-Race (9,87%), apresentaram os menores volumes percentuais médios de material obturador remanescente, não havendo diferença estatística significante entre eles; porém, apresentaram diferença estatística significante (p 0,05) do grupo Mtwo Retratamento (33,88%). Os três sistemas provocaram desgaste semelhante de dentina após a desobturação. O grupo D-Race apresentou menor tempo para desobturação, estatisticamente diferente em relação aos demais sistemas. As características dos sistemas de retratamento podem interferir na eficiência de desobturação quanto ao tempo e volume de material remanescente. / The present study aimed to evaluate, ex vivo, the efficiency of systems for retreatment (ProTaper Universal Retreatment, Mtwo Retreatment and D-Race), in removal filling material of curved mesiobuccal canals of maxillary molars, using cone beam computed tomography. Were used mesiobuccal canals with curvature between 20 ° and 40 °, of 36 molars prepared with ProTaper Universal (until instrument F2), filled with cone F2 ProTaper and AH Plus sealer by lateral condensation. For the removal procedure of filling material, the teeth were divided into groups (I: Protaper Universal Retreatment, II: Mtwo Retreatment and III: D-Race). The capture of images was performed after filling and after the removal procedure of root canal through cone beam computed tomography of small volume (Prexion 3D - XTrillion Inc). The images were segmented using the software InVesalius to check the remaining filling material. The time for removal procedure was also analyzed. Possession of values, initial and final, of volume filling material and dentin structure, the ratio of the volumes was calculated. For statistical analysis, the results were evaluated by ANOVA and Bonferroni\'s Multiple Comparisons. ProTaper Universal Retreatment (13.97 %) and D-Race (9.87 %) groups had the lowest average percent volume remaining filling material, with no statistically significant difference between them, but showed a statistically significant difference (p 0.05) group Mtwo Retreatment (33.88 %). The three systems caused similar wear dentin after removal procedure. The group D-Race had less time for removal procedure, statistically different compared to the other systems. The characteristics of retreatment systems may interfere with the efficiency of removal procedure on the time and volume remaining material.
329

Metodologia para obtenção de imagens periapicais por meio da manipulação de tomografias computadorizadas de feixe cônico para fins forenses / Methodology for obtaining periapical images by the manipulation of Cone-Beam computed tomography for forensic purposes

Curi, Janaina Paiva 29 April 2016 (has links)
A documentação odontológica é utilizada como ferramenta indispensável para identificação humana uma vez que possibilita a comparação entre registros ante mortem (AM) e post mortem (PM), levando a resultados objetivos e confiáveis. A constante evolução tecnológica ocasionou grande avanço na qualidade dos exames por imagens, auxiliando o processo de identificação por arco dentário. Nesse contexto, as imagens radiográficas digitais ganharam espaço frente às convencionais e as tomografias computadorizadas (TC) passaram a ser comumente utilizadas na Odontologia, devido à multiplicidade dos detalhes oferecidos pelas imagens tridimensionais. Estudos recentes revelam as tentativas de se reproduzir imagens semelhantes às intraorais por meio de TC. No entanto, ainda não há estudos efetivos no campo das ciências forenses, utilizando tomografias computadorizadas de feixe cônico (TCFC) com o propósito de identificação. O presente estudo teve como objetivo desenvolver uma metodologia para simulação de imagens radiográficas intraorais em tomografias computadorizadas de feixe cônico, visando repetir a incidência e geometria da radiografia de origem, contemplando os possíveis erros de angulação, além de verificar a eficácia e confiabilidade desse princípio entre os examinadores. Para isso, foi realizada a aquisição de vinte TCFC de crânios secos e os dados do seu odontograma inseridos nas fichas PM do WinID. Para cada crânio, um segundo observador realizou três radiografias periapicais digitais, simulando as AM, uma delas contendo alteração de posicionamento. As 60 radiografias foram randomizadas, três pontos foram selecionados, suas distâncias lineares e angulação mensurados no Photoshop e catalogados em planilha do Microsoft Excel. Os dados odontológicos das radiografias foram incluídos como fichas AM do WinID. O software indicou similaridade ao confrontar os elementos AM com os PM. e os valores tabulados das radiografias conduziram as análises do primeiro, sem o conhecimento prévio dos erros. As regiões de interesse (ROI) das imagens radiográficas foram localizadas nas TCFC e a geometria de incidência simulada, mediante a manipulação dos planos espaciais e ferramentas disponíveis no software Osirix, buscando valores semelhantes aos originais. Por fim, a sobreposição de imagens foi realizada utilizando artifícios do Photoshop, comprovando a similaridade entre as imagens originais e as replicadas na tomografia. Os resultados mostraram que foi possível replicar a geometria das imagens radiográficas nas TCFC em 100% da amostra. Testes estatísticos como o coeficiente de variação, diferenças de médias e coeficiente de Pearson evidenciaram forte correlação para todas as variáveis estudadas e todos os valores foram estatisticamente significantes (p<0.05). O protocolo desenvolvido possibilitou a reprodução da geometria e incidência das radiografias convencionais em TCFC, inclusive na presença de alterações na angulação. As imagens produzidas puderam ser comparadas às originais, assegurando o resultado por sobreposição. Em todas elas ficou comprovada a viabilidade do uso do protocolo para fins de identificação humana e sua aplicação, portanto, foi considerada confiável e segura, visto que a concordância entre os observadores ficou demonstrada pelos testes estatísticos. / Dental Records are used as a necessary tool for human identification, as it enables the comparison of Antemortem (AM) and Postmortem (PM) data, leading to objective and reliable results. The constant evolution of technology brought advances in the quality of images, aiding the dental arch identification process. In this context, the digital radiographic images gained ground among conventional radiographs and Computed Tomography (CT) became usual in dentistry, due to the multiple details available in the tridimensional images. Recent studies shown attempts of reproducing intraoral images from CT. But there was no effective studies in the forensic science field using Cone-Beam Computed Tomography (CBCT) with identification purposes. The present study aims on developing a methodology that could simulate intra-oral images in CBCT exams, in order to repeat the incidence and image geometry of the original radiography, covering possible angulation errors and testing the reliability of the process. To do so, 20 CBCT were acquired from dry skulls and their dental charts were registered in WinID. In each cranium, a second observer made three periapical radiographs, simulating the AM records in WinID, and one should contain and incidence error. The 60 radiographs were randomized and in each three points were selected with linear distances and angle between them were measured in photoshop and recorded in a MS Excel chart. The data from the radiographs were included in WinId as AM records. The Sotware indicated similarities of the records by matching AM and PM, and the values from the radiographs directed the analysis made by the first examiner, with no knowledge of the previous errors and the AM data registered in WinID. The Region of Interest (ROI) in the radiographs were located in the CBCT and the geometry and incidence were simulated using the manipulation of the orientation planes and tools of the software Osirix, in search of similar to the original values. Finally, the superimposition of images was made in Photoshop, to prove the achievement of similarity between the original images and those extracted from the CBCT. The results showed a possible repeatability of image geometry in 100% of the sample. Statistic test of the variance coefficient, average difference and Pearson coefficient highlighted the strong correlation of all variables and significance of all tested values (p<0.05). The developed protocol enabled the reproduction of conventional radiographs geometry and incidence in CBCT exams, including in the presence of incidence errors. The produced images could be compared to the original, assuring a result by superimposition. In every analysis, the use of this protocol has been confirmed as viable for human identification purposes, and its usage was considered reliable and secure, as the concordance between examiners was demonstrated by the statistic analysis.
330

Utilização de imagens tridimensionais da cavidade sinusal frontal provenientes de tomografia computadorizada de feixe cônico para a identificação forense / Usage of tridimensional cone beam computed tomography imaging of the frontal sinus for human identifications in Forensic Scienses

Duailibi Neto, Eduardo Felippe 06 July 2016 (has links)
A unicidade da cavidade sinusal frontal é um importante fator para a identidade humana. O uso de registros de imagens dessa cavidade para a identificação forense é amplamente difundido, sendo uma metodologia secundária segundo a INTERPOL. Recentes avanços nas tecnologias de imagem permitiram o registro de imagens tridimensionais dessa cavidade. Nosso objetivo foi validar a metodologia proposta por Beaini et al. (2015), padronizando critérios para a obtenção de imagens tridimensionais da cavidade sinusal frontal com tomografia computadorizada de feixe cônico e avaliando a capacidade desses dados para a identificação humana. Para tanto, utilizamos um banco de imagens tomográficas de 200 pacientes randomizados e analisados por três observadores. As imagens foram exportadas em formato DICOM e submetidas a dois processos de segmentação distintos e sobreposição tridimensional. Realizou-se a metodologia descrita para estabelecer a identificação entre pacientes randomizados. Os resultados mostraram que há uma diferença significativa entre os processos de segmentação, sendo mais indicada a técnica de segmentação manual. A metodologia proposta por Beaini et al. (2015) foi validada e um total de 166 pacientes foram identificados. O volume da cavidade sinusal possui um elevado potencial de identificação com uma probabilidade aproximada de 85% para determinar o gênero dos indivíduos. / The uniqueness of the frontal sinus cavity is an important factor for establishing human identity. The usage of imaging records of this cavity for human identity is a secondary methodology according to the INTERPOL protocols. Recent advances in imaging technologies have enabled the three-dimensional imaging records of this cavity. Our goal was to validate the methodology proposed by Beaini et al. (2015), by developing standardized criteria for the use of cone beam computed tomography three-dimensional images of the front sinus and evaluating the ability of these data for human identification. The aim of this study was to investigate a total of 200 imaging records from randomized patients that were analyzed by three observers. Images were exported in DICOM format and underwent two distinct segmentation processes and a three-dimensional overlap. The Beaini et al. (2015) technique was applied to establish identification of the randomized patients. My results showed a significant difference between both segmentation processes, with manual segmentation showing the best results. Beaini et al. (2015) technique was validated and a total of 166 patients were identified. The volume of the sinus cavity has a high identification probability with a rough probability of 85% to determine the sex of individuals.

Page generated in 0.0672 seconds