• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 568
  • 164
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 9
  • 8
  • 4
  • 4
  • 2
  • Tagged with
  • 815
  • 815
  • 518
  • 484
  • 154
  • 137
  • 127
  • 114
  • 101
  • 85
  • 80
  • 77
  • 75
  • 74
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
631

Avaliação dos torques para inserção, remoção e fratura de diferentes miniimplantes ortodônticos em cortical de tíbia bovina / Evaluation of the insertion, removal and fracture torques of different orthodontic mini-implants in bovine tibia cortex

Maria Fernanda Prates da Nova 22 February 2008 (has links)
A utilização de grupos de dentes ou de aparelhos dependentes de cooperação, como mecanismos de ancoragem, podem ser fatores limitantes para o sucesso de terapias ortodônticas. Tal fato incentivou a busca de métodos para ancoragem esquelética ou absoluta, que incluem os miniimplantes ortodônticos. Comercialmente estão disponíveis em diversas dimensões e desenhos, porém existem poucas informações sobre a relação de sua morfologia com falhas clínicas ou fraturas. O objetivo deste trabalho foi avaliar o comportamento de miniimplantes com formas diferentes para os seguintes fatores: (a) torque máximo de inserção, (b) torque máximo de remoção, (c) torque de fratura, (d) tipo de fratura, (e) tensão cisalhante e tensão normal. Foram utilizados 20 miniimplantes autoperfurantes, 10 da marca SIN e 10 da Neodent, com 1,6 mm diâmetro e com 8 e 7 mm de comprimento, respectivamente. Destes 10 miniimplantes, 5 não possuíam perfil transmucoso e 5 tinham perfil de 2mm, formando assim 4 grupos: SIN sem perfil (SSP), SIN com perfil (SCP), Neodent sem perfil (NSP) e Neodent com perfil (NCP). Todos os miniimplantes foram inseridos em cortical de tíbia bovina e depois removidos com micro-motor acoplado a um torquímetro digital que registrou os torques máximos de inserção e de remoção. Os miniimplantes que não fraturaram durante os ensaios de inserção e remoção foram submetidos ao ensaio de fratura realizado em máquina universal de ensaios Emic. Os torques de inserção, remoção e fratura, assim como a tensão cisalhante e normal calculadas foram comparados entre todos os grupos. O tipo de fratura foi avaliado pela tensão cisalhante e por avaliação em microscópio eletrônico de varredura (MEV). Para cada grupo comparou-se os torques de inserção e de remoção. Todas as comparações foram feitas através da ANOVA. Verificou-se que o grupo NCP apresentou torque máximo de inserção significativamente maior que os demais grupos (30,6 1,8 Ncm), porém todos fraturaram durante os ensaios de inserção (n=2) ou de remoção (n=3). Não houve diferença significativa entre os grupos para o torque de remoção. Apenas o grupo SSP apresentou diferença significativa entre os torques de inserção e de remoção, para o mesmo grupo. Para o grupo NSP o torque de fratura foi significativamente menor do que todos os outros grupos (27,42 1,14 Ncm). Não houve diferença significativa entre as tensões cisalhante e normal entre os grupos, demonstrando que todos os miniimplantes sofreram fratura do tipo dúctil, confirmado através do MEV. Uma vez que os miniimplantes de todos os grupos são confeccionados com a mesma liga metálica, variando apenas na forma, conclui-se que a resistência à fratura pode ser afetada por esta variável. / The use of groups of teeth or appliances which rely on patient compliance, as anchorage mechanisms, can be limiting factors for the success of orthodontic treatment. This fact encouraged the search for skeletal or absolute anchorage methods, which include orthodontic mini-implants. They are commercially available in different dimensions and designs, but there is scarce information regarding the relation between its morphology and clinical failures or fractures. The purpose of this study was to evaluate the behavior of mini-implants with different forms for the following factors: (a) maximum insertion torque, (b) maximum removal torque, (c) fracture torque, (d) type of fracture, (e) shear tension and (f) normal tension. Twenty self-drilling mini-implants were used, 10 from SIN and 10 from Neodent, with 1.6 mm in diameter and with 8 and 7 mm in length, respectively. Out of these 10 mini-implants, 5 did not have a neck and the other 5 had a 2 mm neck, and were separated into 4 groups: SIN without neck (SSP), SIN with neck (SCP), Neodent without neck (NSP) and Neodent with neck (NCP). All mini-implants were inserted in bovine tibia cortex and later removed with a low speed handpiece connected to a digital torquimeter, which recorded the maximum insertion and removal torques. The mini-implants that did not fracture during insertion and removal assays were submitted to the fracture test, performed in an EMIC universal test machine. The insertion, removal and fracture torques, as well as the calculated shear and normal tensions were compared between all groups. The type of fracture was assessed by the shear tension and by evaluation in scanning electronic microscope (SEM). Insertion and removal torques were compared for each group. All comparisons were done by ANOVA. The NCP group presented a significantly greater insertion torque than all other groups (30.6 1.8 Ncm), but all of them fractured during insertion (n=2) or removal (n=3). There were no significant differences between groups for removal torque. Only group SSP presented a significant difference between insertion and removal torques, for the same group. For group NSP, the fracture torque was significantly smaller than all other groups (27.42 1.14 Ncm). There was no significant difference between shear and normal tensions between groups, demonstrating that all mini-implants suffered ductile fracture, confirmed by SEM. Since mini-implants from all groups are made of the same alloy, varying only in form, one may conclude that resistance to fracture can be affected by this variable.
632

Avaliação da interface osso/implante após o uso do copolímero de PLA/PGA associado a osso autógeno em coelhos: estudo biomecânico e imunohistoquímico

Zanetti, Liliane Scheidegger da Silva [UNESP] 19 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-19Bitstream added on 2014-06-13T21:02:12Z : No. of bitstreams: 1 zanetti_lss_dr_araca.pdf: 1415676 bytes, checksum: 6158721af6f6a1ee60c101f886650479 (MD5) / Este estudo avaliou o uso do c opolímero de ácido poliláctico e poliglicólico (PLA/PGA) associado ao osso autógeno raspado, no reparo ósseo ocorrido ao redor de implantes inseridos em leitos sobrefresados, em tíbias de coelhos. (2) Material e métodos: Foram incluídos no estudo 20 coelhos e inseridos 40 implantes, divididos em dois grupos: Controle (C) e PLA/PGA adicionado a osso autógeno (G). Após fresagem controlada para simular a perda da estabilidade primária, cada implante foi inserido no leito preparado, tendo sido adicionado a sua superfície o copolímero PLA/PGA associado a osso autógeno raspado obtido manualmente. O grupo controle consistiu do implante com o espaço do leito preenchido por coágulo sangüíneo. Os animais foram sacrificados nos períodos de 15, 40 e 60 dias pós-operatórios, e foram realizadas as análises biomecânica e Imunoistoquímica. As tíbias onde estavam inseridos os implantes foram removidas, desc alcificadas, crioprotegidas e obtidos cortes que foram submetidos à reação imunoistoquímica mediante a utilização de anticorpos primários para RANKL, OPG e OC. No período de 60 dias pós-operatórios a analise biomecânica de torque-reverso foi realizada antes da descalcificação. (3) Resultados: Os resultados obtidos demonstraram que o copolímero PLA/PGA misturado ao osso autógeno apresentou-se biocompatível, bioabsorvivel e permitiu a neoformação óssea em contato com o implante, revelada pela análise da expressão das proteínas que regulam o ganho e a perda de massa óssea. E, houve predominância significante de deposição óssea e estabilidade revelada pela análise de torque-reverso (a= 0,05). (4) Conclusões: O copolímero de PLA/PGA pode ser utilizado no preenchimento de defeitos sobrefresados ao redor... / This study evaluated the polylactic and polyglycolic acid copolymer (PLA/PGA) with sc raped bone harvest in the bone repair occurrence of implants placed in large stream beds, in rabbit tibia. (2) Materials and Methods: Twenty rabbits had been enclosed in the study and 40 implants, in two groups: Control (C), PLA/PGA with the autologous bone scraped (G). After controlled drilled to simulate the loss of the primary stability, each implant was placed in the prepared stream bed, having been added to its surface the PLA/PGA copolymer with autologous bone scraped manually (G). The control group consisted of the implant placed in the space filled by blood. The animals had been sacrificed in the periods 15, 40 and 60 postoperative days, where the analyses had been carried through biomechanics and imunohistochemistry. The tibias where the implants were inserted had been removed, decalcified, frozen and getting cuts that had been submitted the imunoistochemistry reaction by means of the use of primary antibodies for RANK L, OPG and OC. In the 60 days period postoperative the against-torque biomechanics was carried through before the decalcified. (3) Results: The gotten results had disclosed that the copolymer PLA/PGA with bone graft showed biocompatibility, bioabsorption and allowed bone growing in contact with the implant, disclosed by expression of the proteins that regulate the profit and mass bone loss. And, had significant predominance of bone deposition and stability disclosed by against-torque ( = 0,05). (4) Conclusions: The PLA/PGA copolymer can be used filling defects drilled around implants in tibia of rabbits, when added bone harvest sc raped, therefore it presents characteristic s like biocompatibility and biodegradation, being totally resorpted and substituted by bone, allowing the bone formation with quality in the interface bone/implant.
633

Avaliação das alterações dos tecidos ao redor de implantes inseridos em diferentes níveis em relação à crista óssea: estudo clínico, radiográfico, e histométrico em cães

Pontes, Ana Emilia Farias [UNESP] 01 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-01Bitstream added on 2014-06-13T20:45:03Z : No. of bitstreams: 1 pontes_aef_dr_arafo.pdf: 2180778 bytes, checksum: 4f081c1f4701944b8a6da04a94fa99b3 (MD5) / O objetivo do presente estudo foi avaliar alterações ao redor de implantes inseridos em diferentes níveis em relação à crista óssea, e sob diferentes protocolos de restauração. Trinta e seis implantes foram inseridos nas mandíbulas edêntulas de 6 cães. Três implantes foram instalados por hemi-mandíbula, cada qual representativo de um grupo experimental. Estes foram determinados de acordo com a distância entre a junção implante-conector protético (JIC) e a crista óssea: Ao Nível (ao nível da crista óssea), Menos 1 (1mm apical à crista óssea), ou Menos 2 (2mm apical à crista óssea). Cada hemi-mandíbula foi submetida a um protocolo de restauração: convencional (prótese instalada 120 dias após a implantação) ou imediata (prótese instalada 24 horas após a implantação). Parâmetros clínicos, radiográficos, e histométricos foram avaliados após 90 dias de restauração, e os dados foram analisados estatisticamente (alfa=5%). A posição da margem do tecido mole (PTM) não foi influenciada pelo posicionamento apical da JIC; entretanto, sítios submetidos à restauração imediata tiveram a PTM significantemente mais coronal que os submetidos à restauração convencional (p=0,02, análise clínica). A reabsorção do rebordo não foi estatisticamente diferente entre os grupos (p>0,05, análise radiográfica). Menores quantidades de Perda Óssea Lateral (POL) foram observadas nos sítios restaurados imediatamente em comparação com os restaurados convencionamente (p=0,006, análise histométrica). Os presentes achados sugerem que o posicionamento apical da JIC não põe em risco a altura de tecidos periimplantares moles ou duros. Além disto, a restauração imediata foi benéfica para manter a PTM, e minimizar a POL. / The aim of the present study was to evaluate changes that occur around dental implants inserted in different levels in relation to crestal bone, under different restoration conditions. Thirty-six implants were inserted in the edentulous mandible of six dogs. Three implants were inserted per hemimandible, each one representing an experimental group according to the distance from the implant-abutment junction (IAJ) to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1mm below crestal bone), or Minus 2 group (2mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prothesis installed 120 days after implant placement) or immediate (prosthesis installed 24 hours after implant placement). Clinical, radiographic, and histometric parameters were evaluated after 90 days of restoration, and data was analyzed statistically (alpha=5%). The position of soft tissue margin (PSTM) was not influenced by the apical positioning of the IAJ; however, sites submitted to immediate restoration had the PSTM displayed significantly more coronally than those submitted to conventional restoration (p=0.02, clinical analysis). Ridge Loss was not statistically different among groups (p>0.05, radiographic analysis). Greater amounts of Lateral Bone Loss (LBL) were observed for conventionally than for immediately restored sites (p=0.006, histometric analysis). These findings suggest that the apical positioning of IAJ did not jeopardize the height of peri-implantar soft and hard tissues. Moreover, immediate restoration was beneficial to maintain the PSTM, and to minimize LBL.
634

Reparação óssea em enxerto alógeno fresco congelado na calvária de coelhos: análises histológica e histomorfométrica

Macedo, Luís Guilherme Scavone de [UNESP] 06 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-06Bitstream added on 2014-06-13T21:07:04Z : No. of bitstreams: 1 macedo_lgs_dr_sjc.pdf: 1328056 bytes, checksum: 2dc22b18ce2b29898eeed7a8c9f63b1d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A utilização de enxerto ósseo autógeno previamente à instalação de implantes osseointegráveis tem apresentado bons resultados, entretanto, a necessidade de uma segunda área cirúrgica como fonte doadora e o grau de morbidade da técnica têm direcionado a busca por alternativas seguras para a reconstrução óssea. O propósito desta pesquisa foi avaliar o efeito do enxerto de osso alógeno fresco congelado, oriundo de Banco de Tecido, em comparação ao autógeno no processo de reparação de enxertos na calvária de coelhos. Foram utilizados 15 coelhos adultos, nos quais foram realizados 2 enxertos em blocos nos ossos parietais, divididos aleatoriamente nos seguintes grupos de acordo com o tratamento: autógeno (A – enxerto com osso autógeno) e alógeno (B – enxerto com osso alógeno processado em Banco). Decorridos 15, 30 e 60 dias, 5 animais foram sacrificados por período, sendo as peças contendo os enxertos processadas para análises histológica e histomorfométrica. Os resultados foram submetidos ao teste RM ANOVA e de comparação múltipla de Tukey, demonstrando diferenças estatisticamente significantes entre os grupos e entre os tempos estudados. Concluímos que o enxerto alógeno promove formação óssea, porém em menor quantidade e de forma mais lenta em comparação ao enxerto autógeno / The use of autogenous bone graft prior to installation of dental implants has shown good results, however, the need for a second surgical site and donor source and degree of morbidity of the technique have led the search for safe alternatives to bone reconstruction. The purpose of this study was to evaluate the effect of allogeneic bone graft, fresh frozen from Bank of tissue, as compared to autograft in the repair of calvarial grafts in rabbits. A total of 15 adult rabbits, in which grafts were performed in two blocks in the parietal bone were divided randomly into four groups according to treatment: autogenous (A - with autogenous bone graft) and allogeneic (B - allogeneic bone graft processed in Bank Bone). After 15, 30 and 60 days, five animals were sacrificed by period, and the pieces containing the grafts were processed for histology and histomorphometry. The results were submitted to the RM ANOVA and Tukey's multiple comparison, statistically significant differences between groups and between time points. We conclude that allograft promotes bone formation, but fewer and more slowly compared to autografts
635

Influência da altura da coroa em implantes osseointegrados: estudo pelo método dos elementos finitos tridimensionais

Moraes, Sandra Lúcia Dantas de [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T18:46:01Z : No. of bitstreams: 1 moraes_sld_dr_araca.pdf: 1714349 bytes, checksum: d5ff02883440cb484b8e2bd8528c5f78 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os implantes dentais têm sido usados extensivamente para a reabilitação de edentulismo total e parcial, com próteses fixas ou removíveis. Em detrimento das suas taxas de sucesso e previsibilidade, falhas ocorrem e são associadas a complicações biomecânicas. Entre os fatores biomecânicos podemos destacar uma proporção adequada entre comprimento do implante e superestrutura. Porém, pouco é encontrado sobre a influência da altura da coroa, o alcance do braço de alavanca e, conseqüentemente, a tensão no osso cortical e no osso trabecular. Apesar do aumento no uso de implantes, muito pacientes que necessitam dessa terapia ficam limitados devido à pouca altura óssea. Sistemas disponibilizam no mercado implantes curtos, onde procedimentos cirúrgicos invasivos poderiam ser evitados; nesses implantes, porém, é muito comum uma relação coroa/área implantada invertida. Desenvolveremos este trabalho em dois capítulos. O primeiro irá avaliar a influência de três alturas de coroas pré-estabelecidas, quando associadas a implantes de hexágono externo em todas as suas estruturas associadas. No segundo, avaliaremos a influência das mesmas alturas de coroas, associadas a implantes de hexágono externo e cone - morse, na distribuição das tensões no tecido ósseo. Para a primeira parte do trabalho, foram confeccionados três modelos tridimensionais, com auxilio dos programas de modelagem gráfica SolidWorks 2006 e Rhinoceros 4.0, além do programa InVesalius (CTI, São Paulo, Brasil), utilizado para gerar o modelo ósseo a partir de uma tomografia computadorizada. Cada modelo foi composto por um bloco ósseo, com um implante de 3,75 x 10,00mm (Conexão Sistemas de Prótese, São Paulo), com o tipo de conexão: hexágono externo, utilizando três alturas de coroas (10 mm; 12.5 mm e 15 mm), colocadas na plataforma oclusal (hexágono externo). Após geração... / The dental implants have been widely used for rehabilitation of partial and complete edentulism using fixed and removable prostheses. Despite the success rate and predictability, failures are reported and commonly associated with biomechanical complications. Among the biomechanical factors, an adequate proportion between the implant and superstructure dimensions should be established. However, there is little information about the influence of crown height and lever arm on stress in cortical and trabecular bone. Although the use of implants has increased, many patients are limited by insufficient bone height. Thus, some implant systems developed short implants to avoid invasive surgical procedures. Nevertheless, such implants present an inverted crown/anchored area ratio. The present study will be divided into two chapters. The first one will evaluate the influence of three pre-established crown heights attached to external hexagon implants on all structures. In the second chapter, it will be evaluated the influence of the same crown heights attached to external hexagon and morse taper implants on the stress distribution in bone tissue. Initially, three 3D models were fabricated using the softwares SolidWorks 2006 and Rhinoceros 4.0. The software InVesalius (CTI, Sao Paulo, Brazil) was also used to generate the bone model through a computed tomography. Each model was composed by a bone block with an external hexagon implant (3.75 X 10.0 mm) (Conexao Sistemas de Protese, Sao Paulo) and a crown with different heights (10 mm, 12.5 mm and 15 mm) attached to the implant platform (external hexagon). After generation of the geometries, the models were imported to the software FEMAP 10.0 (Siemens PLM Software Inc., USA) for pre- and post-processing of finite elements to generate the meshes as well as the loading and boundary conditions. Axial load of 200N and oblique load of 100N were ... (Complete abstract click electronic access below)
636

Biokompatibilita implantabilních materiálů se zaměřením na titanové dentální implantáty / Biocompatibility of Implantable Materials Focused on Titanium Dental Implants

Moztarzadeh, Amin January 2017 (has links)
This dissertation thesis deals with the evaluation of biocompatibility and osseointegration of nanostructured titanium materials used for dental implants. Bulk material topography and surface modification of titanium are currently of intense research mainly due to the significant impact on biocompatibility and improvement of osseointegration of dental implants. In the theoretical part are described types of titanium material and different methods of its surface modification. In vitro and in vivo biocompatibility and osseointegration tests are described as well. The experimental work consists of two parts of experiments. In the first experiment, we examined how grain size of nanostructured titanium material influences the behaviour of fibroblastic as well as osteoblastic cells growth on its surface. The experimentally obtained data were statistically analysed and discussed. Grain size was proven to be an important factor that influenced not only the strength of material but also its interactions with cells. The second experiment describes current methods used in the experimental evaluation of osseointegration of dental implants. The results of histological staining methods are illustrated and compared. A standardized and reproducible technique for stereological quantification of bone-implant contact...
637

Membrana reabsorvível com enxerto ósseo autógeno ou BoneCeramic em rebordos atróficos em implante de titânio : estudo histométrico em cães /

Hayacibara, Roberto Masayuki. January 2011 (has links)
Orientador: Osvaldo Magro Filho / Banca: Wilson Roberto Poi / Banca: Idelmo Rangel Garcia Júnior / Banca: Márcio de Moraes / Banca: Angelo José Pavan / Resumo: Propósito: O objetivo deste estudo foi avaliar histometricamente as alterações ósseas dimensionais, que ocorrem em rebordo atróficos induzidos experimentalmente, com a colocação de implante e enxerto ósseo autógeno ou grânulos de hidroxiapatita/fosfato β-tricálcio (BC) associados à membrana reabsorvível (MR). Materiais e Métodos: Defeitos ósseos foram criados após a extração dos 3 e 4 pré-molares mandibulares de cinco cães beagle. Após 3 meses, foram colocados 2 implantes em cada lado da mandíbula, dentro do rebordo atrófico, resultando em aproximadamente 6mm de superfície exposta do implante. Três grupos de tratamento foram distribuídos aleatoriamente: sem tratamento, MR + Osso autógeno (OA), MR + grânulos de hidroxiapatita/fosfato β-tricálcio. Após 4 meses, os cães foram sacrificados e foi realizada análise histométrica para avaliação de contato osso implante (COI) e ganho ósseo vertical (GOV). As médias de COI e GOV dos três grupos foram comparadas pelo teste de Tukey ao nível de significância de 5%. Resultados: Em 4 meses, o tratamento com MR+OA mostrou COI (%): 26.41 ± 4.90 e GOV (%): 16.06 ± 11.83. O grupo com MR+BC obteve COI (%): 15.16 ± 2.40 e GOV (%): 7.45 ± 9.84 e o grupo A mostrou COI (%): -0.23 ± 0.50 e GOV (%): -1.09 ± 8.99. O grupo MR+OA mostrou regeneração óssea maior (COI e GOV) que o grupo MR+BC e o grupo A (p<0.05). O grupo MR+BC obteve regeneração óssea maior (COI) que o grupo A (p<0.05). Conclusão: Concluiu-se que em rebordos atróficos: (i) tratamento com MR+OA aumenta a regeneração óssea, incluindo ganho ósseo vertical e contato osso implante; (ii) ocorre perda óssea na ausência de técnicas regenerativas / Abstract: Purpose: The objective of this study was to evaluate histometric bone dimensional changes that occur in atrophics defects induced experimentally by placing the implant and autogenous bone graft or hydroxyapatite/β-tricalcium phosphate granules (BC) associated with reabsorbable membrane (RM). Material and Methods: A defect was created after the extraction of three four mandibular premolars of five beagle dogs. After 3 months, 2 implants were placed on each side of the mandible, within the atrophics defects, resulting in approximately 6 mm exposed surface of the implant. Three treatment groups were randomly assigned to: untreated control, RM + autogenous bone, RM + hydroxyapatite /β-tricalcium phosphate granules. After four months, the dogs were sacrificed and histometric analysis was performed to evaluate bone implant contact (BIC) and vertical bone gain (VBG). Mean BIC and VBG in the three groups were compared by Tukey test at a significance level of 5%. Results: In 4 months, treatment with RM + autogenous bone showed BIC (%): 26.41 ± 4.90 and VBG (%): 16.06 ± 11.83. The group RM + BC showed BIC (%): 15.16 ± 2.40 and VBG (%): 7.45 ± 9.84 and the A group obtained BIC (%): -0.23 ± 0.50 and VBG (%): - 1.09 ± 8.99. The RM + autogenous bone group showed greater bone regeneration (BIC and VBG) that RM + BC group and A group (p <0.05). The group received RM + BC greater bone regeneration (BIC) than the A group (p <0.05). Conclusion: We conclude that in atrophics defects: (i) RM + autogenous bone treatment increases bone regeneration, including vertical bone gain and bone implant contact, (ii) bone loss occurs in the absence of regenerative techniques / Doutor
638

Avaliação comparativa da viabilidade celular imediata após osteotomia para implantes com fresas e piezocirurgia em tíbias de coelhos: análise imunoistoquímica

Pereira, Cassiano Costa Silva [UNESP] 01 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-01Bitstream added on 2014-06-13T18:19:48Z : No. of bitstreams: 1 pereira_ccs_me_araca.pdf: 1524857 bytes, checksum: 29dbf40d228058d4769e3d3ef3821153 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito desse trabalho foi avaliar o efeito da osteotomia para implantes sobre a viabilidade celular óssea imediata, comparando a utilização de fresas do sistema convencional com a piezocirurgia em tíbias de coelhos. Foram utilizados 6 coelhos machos, divididos em 2 etapas: (1) Fresas – 5 grupos (G1 a G5) correspondentes às osteotomias 10, 20, 30, 40 e 50 vezes, respectivamente. Cada leito ósseo recebeu a sequência de fresas: lança e helicoidais de 2,0 mm, 2,8 mm, 3,0 mm e 3,15 mm; (2) Piezocirurgia – 5 grupos (P1 a P5) correspondentes às osteotomias 10, 20, 30, 40 e 50 vezes, respectivamente, efetuadas pela sequência de pontas de 2,0 e 3,0 mm, mediante vibração ultrassônica piezoelétrica. As áreas osteotomizadas foram coletadas e processadas laboratorialmente. A análise imunoistoquímica demonstrou equilíbrio das expressões de OPG e RANKL, ou seja, formação e reabsorção óssea, tanto nas osteotomias com fresas, quanto na piezocirurgia, embora mais intensas nesta última. A expressão de OC apresentou-se bastante intensa nos grupos de piezocirurgia, mas com redução da imunomarcação a partir da 30ª osteotomia, enquanto manteve-se constante nos grupos fresados. A CAS3 evidenciou a viabilidade osteoblástica a partir da 20ª osteotomia com piezocirurgia e manteve-se constante até a 50ª. No grupo de fresas, notou-se aumento gradativo da expressão dessa proteína, conforme o aumento do número de osteotomias. De acordo com a metodologia aplicada, foi possível concluir que a piezocirurgia propicia maior viabilidade celular osteoblástica do que o sistema de fresas convencional / The purpose of this study was to evaluate the effect of the osteotomy implant on bone cell viability immediately, comparing the use of conventional drilling system with piezosurgery® in tibiae of rabbits. We used 6 male rabbits were divided into 2 stages: (1) Drilling - 5 groups (G1 to G5) corresponding to the 10 osteotomies, 20, 30, 40 and 50 times respectively. Each received a bone bed following drills: Spear drill and 2.0 mm, 2.8 mm, 3.0 mm and 3.15 mm helicoidal drills, (2) Piezosurgery® - 5 groups (P1 to P5) corresponding to the 10 osteotomies, 20, 30, 40 and 50 times, respectively, analyzed by the sequence of inserts 2 and 3 mm by piezoelectric ultrasonic vibration. The receptor-beds were collected and processed in a laboratory. The immunohistochemical analysis showed balance expressions of OPG and RANKL, ie bone formation and resorption in both the osteotomies with drills and piezosurgery®, although more intense in the latter. The expression of OC had become quite intense in piezosurgery® groups, but with reduced immunostaining from the 30th osteotomy, while remained unchanged in groups drilled. The CAS3 showed the viability of the osteoblast from the 20th osteotomy with piezosurgery® and remained constant until the 50th. In the group of drills noticed a gradual increase in the expression of this protein, as the increase in the number of osteotomies. According to the methodology, it was concluded that the piezosurgery® provides greater osteoblastic cell viability than the system of conventional drilling
639

Comportamento biomecânico de implantes retos e angulados sobre cargas axiais e não axiais por análise de elementos finitos e extensometria linear / Behavior of implants straight and angled with axial load and non-axial, on finite elements and linear strain gauge analysis

Tribst, João Paulo Mendes [UNESP] 18 January 2017 (has links)
Submitted by JOÃO PAULO MENDES TRIBST (joao.tribst@fosjc.unesp.br) on 2017-01-26T19:06:37Z No. of bitstreams: 1 merged (3).pdf: 2530158 bytes, checksum: 8e235a2d5347c6969e7816c0f8e75e91 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-30T19:35:24Z (GMT) No. of bitstreams: 1 tribst_jpm_me_sjc.pdf: 2530158 bytes, checksum: 8e235a2d5347c6969e7816c0f8e75e91 (MD5) / Made available in DSpace on 2017-01-30T19:35:24Z (GMT). No. of bitstreams: 1 tribst_jpm_me_sjc.pdf: 2530158 bytes, checksum: 8e235a2d5347c6969e7816c0f8e75e91 (MD5) Previous issue date: 2017-01-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho buscou estudar as microdeformações geradas ao redor de implantes de hexágono externo durante carregamentos axiais e não axiais, variando-se a angulação dos implantes, utilizando a análise por elementos finitos e a extensometria linear como ferramentas. Inicialmente modelos 3D de diferentes próteses fixas foram construídos a fim de se permitir uma correlação dos resultados encontrados no modelo simplificado com o modelo anatômico e assim validar a geometria da prótese utilizada no estudo. Após a confirmação dos resultados de tensão similar entre as próteses na região dos implantes e do bloco, o modelo da prótese simplificada foi definida como válida. Em seguida, um modelo de bloco de poliuretano foi criado e duplicado. Implantes com conexão de hexágono externo (HE) foram modelados e em um bloco representados perpendiculares à superfície enquanto que em outro bloco foram colocados com inclinação de 17°. Foram modelados também intermediários do tipo mini pilar cônico retos e angulados conforme a inclinação dos implantes. Por último, foi utilizado o modelo de supraestrutura previamente validada para ambos os grupos, na qual a carga foi incidida. Todos os constituintes foram considerados perfeitamente simétricos, sólidos, isotrópicos. Os modelos receberam cargas de 300 N/cm em pontos axiais e não axiais através do software de análise por elementos finitos para se verificar a tensão máxima principal e as microdeformações. Em seguida, através da análise experimental de extensometria, dois blocos de poliuretano foram confeccionados e receberam três HE cada, bem como, respectivos mini pilares cônicos de acordo com a inclinação dos implantes instalados. Então, uma supraestrutura metálica, idêntica ao modelo computacional foi fundida em NiCr e parafusada sobre os implantes com torque de 10 N/cm. Foram aplicadas cargas de 300 N/cm durante 10 segundos em pontos axiais e não axiais. Para mensurar as microdeformações, foram colados quatro extensômetros na superfície de cada bloco tangenciando os implantes. Os dados obtidos foram analisados estatisticamente através dos testes ANOVA e Tukey (α=5%). Os resultados encontrados pela extensometria mostram que existe diferença significante entre o uso de implantes retos ou inclinados (p<0,005) em uma prótese fixa. Através da correlação das metodologias, pode-se observar que o grupo com implantes inclinados atinge picos de tensão acima do limite fisiológico. / This work aimed to study the microstrains generated around external hexagon implants during axial and non-axial loads, varying the angulation of the implants, using finite element analysis and linear strain gauge as tools. Initially 3D models of different fixed prostheses were constructed in order to allow a correlation of the results found in the simplified model with the anatomical model and thus validate the geometry of the prosthesis used in the study. After confirming the results of similar stress between the prostheses in the implants and the block region, the simplified prosthesis was defined as valid. After, a polyurethane block model was created and duplicated. Implants with external hexagon connection (HE) were modeled and inserted perpendiculary into one block while in another block, were placed with the inclination of 17 °. Straight and angled mini conical abutments were also modeled according to the inclination of the implants. Finally, the supra-structure previously validated for both groups was used, through which the load was affected. All constituents were considered perfectly symmetrical, solid, and isotropic. The models received a load of 300 N / cm in axial and non-axial points through the finite element analysis software, to verify the maximum principal stress and microstrains. Then, through the experimental analysis of strain-gauge, two polyurethane blocks were prepared and received three HE implants each, as well as respective mini tapered pillars according to the inclination of the installed implants. Then, a metallic superstructure, identical to the computational model, was cast in Ni-Cr and screwed onto the implants with torque of 10 N / cm. The load of 300 N / cm was applied for 10 seconds at axial and non-axial points. To measure the microstrains, four extensometers were glued on the surface of each block by tangential implants. The data obtained were statistically analyzed using ANOVA and Tukey tests (α = 5%). S strain-gauge data showed that there is a significant difference between using straight or angled implants (p <0.005) in a fixed prosthesis. And, through the correlation of methodologies it can be observed that the group with angled implants reaches peaks of tension above the physiological limit.
640

Avaliação radiográfica e biomecânica da influência da osteoporose induzida em ratas, e seu tratamento com alendronato e estrógeno, sobre o tecido ósseo ao redor de implantes com osseointegração estabelecida /

Giro, Gabriela. January 2006 (has links)
Resumo: O presente estudo teve como objetivo avaliar a influência da deficiência de estrógeno promovida pela ovariectomia (OVX) sobre o tecido ósseo ao redor de implantes com osseointegração estabelecida. Foram utilizadas ratas Wistar, com idade aproximada de 60 dias e peso variando entre 180g a 220g, submetidas à colocação de um implante na metáfise tibial. Os tratamentos utilizados foram eficientes na prevenção da perda óssea. Os animais que receberam a administração do alendronato apresentaram os melhores resultados para todas as análises realizadas. A deficiência de estrógeno decorrente da OVX acarretou prejuízos para a BMD, densidade radiográfica da região de osso medular e torque de remoção dos implantes. Esse quadro pôde ser revertido com a utilização dos tratamentos instituídos, com o alendronato apresentando os melhores resultados. / Abstract: The aim of the present study was to evaluate the influence of estrogen deficiency due to ovariectomy (OVX) on the bone around osseointegrated titanium implants. Wistar female rats - approximately 60 days old, weighting from 180 to 220 g - were used. Digital radiographs were taken and the implants were submitted to the removal toque. The results showed a negative effect of the OVX on the BMD at the femur and lumbar regions, on the radiographic bone density at the cancellous bone and on the biomechanical characteristics of the bone tissue around the implants. The treatments were efficient preventing bone loss. The animals that received alendronate therapy showed the best results for all the analyzed variables. we can conclude that the estrogen deficiency due to OVX had a negative influence on the BMD, on the radiographic bone density at the cancellous bone and on the removal torque of the implants; however, such negative influence can be reversed with the adopted therapies, among which the alendronate seemed to be the best method for prevention and treatment of bone loss due to OVX. / Orientador: Silvana Regina Perez Orrico / Coorientador: Elcio Marcantonio Junior / Banca: Luiz Antonio Pugliesi Alves de Lima / Banca: Roberto Henrique Barbeiro / Mestre

Page generated in 0.075 seconds