• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • 1
  • Tagged with
  • 38
  • 17
  • 10
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Confiabilidade e análise fisiológica de um teste isométrico de fadiga muscular localizada /

Souto, Larissa Rodrigues. January 2018 (has links)
Orientador: Carlos Marcelo Pastre / Banca: Fabio Micolis de Azevedo / Banca: Marcelo Papoti / Resumo: Introdução: Testes físicos confiáveis, capazes de identificar uma mudança real no desempenho proveniente de intervenções fisioterapêuticas e/ou do treinamento físico, são de extrema importância para a prescrição de exercícios físicos . Sua aplicação fornece parâmetros individualizados da performance muscular, permitindo uma adequada implementação de cargas durante a dinâmica de treinamento e/ou reabilitação. Além da aplicação de tais testes, avaliar a demanda metabólica durante sua execução é de extrema importância na prática clínica proporcionando parâmetros fisiológicos tanto para a avaliação como para a implementação da dinâmica de cargas. Objetivos: Verificar a confiabilidade intra e inter-avaliadores de um teste isométrico de fadiga muscular (TIFM) do quadríceps do membro inferior dominante realizado no dinamômetro isocinético e analisar a demanda metabólica exigida durante a sua execução. Métodos: O estudo foi dividido em duas etapas, sendo a primeira referente a análise da confiabilidade intra e inter-avaliadores do TIFM e a segunda em relação a análise da sua demanda metabólica. A primeira etapa do estudo consistiu em três sessões: familiarização, teste e reteste. Nessa etapa foi verificada a confiabilidade em relação as variáveis de desempenho tempo, energia e pico de torque (PT). Para a realização da segunda etapa o participante foi submetido a duas sessões: familiarização e teste. Na sessão de teste, houve análise de gases e da concentração sanguínea de lactato par... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Reliable physical tests, capable of identifying a real change in performance from physiotherapeutic interventions and/or physical training, are extremely important for the prescription of physical exercises. Its application provides individualized parameters of muscular performance, allowing an adequate implementation of loads during training and/or rehabilitation dynamics. In addition to the application of such tests, evaluating the metabolic demand during its execution is extremely important in clinical practice, providing physiological parameters for both evaluation and implementation of load dynamics. Objectives: To verify the intra- and inter-rater reliability of an isometric muscle fatigue test (IMFT) of the dominant lower limb quadriceps performed on the isokinetic dynamometer and to analyze the metabolic demand required during its execution. Methods: The study was divided in two phases, the first one referring to the analysis of intra- and inter-rater reliability of the IMFT and the second one in relation to the analysis of its metabolic demand. The first phase of the study consisted of three sessions: familiarization, test and retest. In this phase the reliability of the time, energy and peak torque (PT) variables was verified. For the second phase the participant was submitted to two sessions: familiarization and test. In the test session, there was gas analysis and blood lactate concentration to determine the energy contribution and analysis of muscle... (Complete abstract click electronic access below) / Mestre
12

Confiabilidade de um teste para avaliar resistência muscular localizada em músculos extensores de joelho com tubos elásticos e dinamômetro isocinético /

Silva, Jaqueline Santos. January 2017 (has links)
Orientador: Carlos Marcelo Pastre / Banca: Fabio Mícolis de Azevedo / Banca: Fabio do Nascimento Bastos / Resumo: Introdução: Testes confiáveis que sejam capazes de mensurar a resistência são importantes ferramentas no contexto clínico, auxiliando nos processos de avaliação física e progressão no quadro clínico de pacientes submetidos ao treinamento resistido e reabilitação física. Uma alternativa que têm crescente popularidade é a utilização de tubos elásticos. Os dispositivos elásticos se destacam pelo fácil manuseio, baixo custo, praticidade e viabilidade de uso. Por outro lado, sendo o dinamômetro isocinético, um equipamento considerado "padrão ouro" em testes de habilidades físicas, considerou-se pertinente a inserção de avaliação do método proposto também neste equipamento, a fim de analisar os desfechos em ambas estratégias utilizadas. Objetivos: Avaliar a confiabilidade teste-reteste do teste de resistência a fadiga muscular localizada (TRF) em duas ferramentas tubos elásticos e dinamômetro isocinético. Métodos: Foram recrutados jovens saudáveis, do sexo masculino, com idades entre 18 e 30 anos para participarem do estudo, que foram divididos em dois grupos: resistência elástica (GRE) e dinamômetro isocinético (GRI). Um total de 179 participantes concluíram o estudo (GRE n=81; GRI n=98). Ambos os grupos realizaram três etapas prévias ao teste intituladas: orientação, apresentação de cargas e familiarização aos equipamentos. Posteriormente, os participantes realizaram o TRF, em duas ocasiões, com intervalo de sete dias entre elas. As análises de confiabilidade foram realizadas por... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Reliable tests that are capable of measuring resistance are important tools in the clinical context, assisting with the physical evaluation and progression of patients submitted to resistance training and physical rehabilitation. An alternative method with increasing popularity is the use of elastic bands, because they are easy to handle, have low cost, feasibility and practicality. On the other hand, the isokinetic dynamometer is considered the "gold standard" for physical skills tests, and we considered pertinent to reproduce physical skills test also with this equipment, to analyze the outcomes. Objective: To analyze the testretest reliability of the localized muscle fatigue resistance test (TRF) using elastic bands and an isokinetic dynamometer. Methods: A total of healthy young adults were recruited to participate in the study, and were divided into two groups: elastic resistance (GRE) and isokinetic dynamometer (GRI). A total of 179 participants completed the study (GRE n = 81; GRI n = 98) The two groups performed four sessions prior to the test, as follows: orientation, presentation of loads, equipment adaptation, and test. Participants performed TRF in two occasions, with a seven-day interval between sessions. We used the intraclass correlation coefficient (ICC) with 95% confidence interval, typical measurement error (ETM) and coefficient of variation (CV) expressed as percentage, to verify the reliability of the tests. Results: In the GRE, the relative ... (Complete abstract click electronic access below) / Mestre
13

Análise do equilíbrio dinâmico do membro inferior em uma situação de instabilidade provocada pela prancha de equilíbrio e tênis instáveis

Silva, Glauce Gonzaga [UNESP] 13 January 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-13Bitstream added on 2014-06-13T20:45:40Z : No. of bitstreams: 1 000733650.pdf: 2558316 bytes, checksum: 8ecbdb2f984832ce1175bef38547929b (MD5) / O equilíbrio corporal é um evento dinâmico que está diretamente relacionado à independência funcional do indivíduo. O objetivo do presente estudo foi investigar a influência de diferentes tipos de calçados e da imobilização da articulação do tornozelo sobreos componentesbiomecânicos do equilíbrio dinâmico.Doze mulheres saudáveis (idade: 27,08± 4,79 anos,IMC: 22,58 ± 2,17 kg/m2) foram analisadas durante uma tarefa de oscilação corporal ântero-posterior sobre umaprancha de equilíbrio em quatro condições: descalças, usando tênis habitual, usando tênis instáveis e com o tornozelo dominante imobilizado em 50% de sua total amplitude de movimento. As análises consistiram em duasetapas: realização da contração voluntária máxima (CVM), condição estática, e oscilação livre, condição dinâmica.Uma plataforma de força foi posicionada sobrea prancha deequilíbrio para avaliar as distribuições das forças de reação. A análise cinemática tridimensional foi realizada para avaliar as oscilações daprancha, do centrode massa edos ângulos articulares do tornozelo. Foi realizadaanálise eletromiográficados músculos reto femoral, tibial anterior,gastrocnêmio medial e lateral do membro dominante. Os valores foram comparados por análise de variância one way e teste T pareado(p<0,10). A análise dinamométrica revelou maior força vertical dereação do solo durante a oscilação anteriorem relaçãoà posterior (p< 0,001). A condição de imobilização foi significativamente maior em relação às demais (p=0,049 para todas). Na análise cinemática, maior ângulo de inclinação da prancha durante a oscilação posterior foi observado (p=0,001). A análise eletromiográfica revelou maior ativação na condição de imobilização (p = 0,08). A maior amplitude de oscilação anterior em relação à posterior... / Body balance is a dynamic event that is directly related to the functional independence of individual. Thepurpose of this study was to investigate the influenceof different typesof shoes and immobilization of the ankle joint on the mechanical componentsof dynamic equilibrium. Twelve healthy women(age: 27.08 ± 4.79 years;BMI: 22.58 ± 2.17 kg/m2) wereanalyzed duringa task anteroposterior body sway on a balanceboard for four conditions: barefoot, with a regular tennis, with an unstable shoes andwith dominant ankle immobilized at 50% of itsfull range of motion. Analysisconsistedof two steps: achievement of maximumvoluntary contraction (MVC), static condition, andfree oscillation, dynamiccondition. One force platformwas properly positioned on the balance board to evaluate the distributions of the reaction forces. Three-dimensional kinematic analysis was performedto evaluate the fluctuationsof the mass center. Electromyographic analysis of therectus femoris,tibialis anterior, medial and lateralgastrocnemius of thedominant limb was performed. Values were compared by one way variance analysis and pared t-test (p<0,10).Dinamometricanalysis showed greater vertical ground reaction force during theanterior body away compared to posteriorbody away (p<0,001). Immobilization condition was significantly higher compared to all conditions (p=0.049 for all). In kinematic analysis, a greater angle of inclination of the board during the posterior body away was observed (p=0,001). Higher activation in immobilization condition was observed in relation to other (p=0,08). Equality of electromyographic values of other muscles investigated was due the co-contraction performed during the oscillations. The largest amplitude of anterior body away compared to the posterior oscillation reflects better conditions fall protection in immobilization condition. Ankle and hip strategies were activated of effective ... (Complete abstract click eletronic access below)
14

Implementação de um sistema de aquisição de dados da técnica de judô Osotogari utilizando dummy na realização do uchikomi / Implementation of a data acquisition system for judo technique Osotogari on uchikomi, applying dummy

Nagata, Eduardo Yoshinori [UNESP] 15 January 2015 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-01-15Bitstream added on 2015-05-14T16:58:52Z : No. of bitstreams: 1 000825292.pdf: 1544038 bytes, checksum: eebdf11dfc6887834c5cb56e25c53d9d (MD5) / O judô é um esporte muito praticado no mundo todo, sendo uma modalidade que exige boa condição física para a melhor performance. Para a execução dos golpes é necessária a coordenação das ações dos membros superiores e inferiores, assim como a força exercida pelos membros ser sincronizada para atingir eficiência no gesto motor. O presente estudo teve por objetivo construir um equipamento de avaliação de desempenho para verificar o comportamento dos sinais de força na execução da técnica de judô Osotogari no treinamento de uchikomi. O equipamento de avaliação de desempenho confeccionado com 4 células de carga que foram posicionados nos 4 contatos do uke (pessoa que recebe o golpe) no tori (pessoa que executa o golpe) ao realizar o golpe. O equipamento foi construído num dummy com uma célula de carga acoplada no peito esquerdo, outra célula de carga posicionada na parte posterior da coxa direita. O dummy foi vestido com um kimono adaptado, e nele foram colocados uma célula de carga na manga direita e outra célula de carga na gola esquerda. Participaram da pesquisa 12 sujeitos com dominância lateral direita, sendo 5 experientes e 7 iniciantes. Os sujeitos realizaram 1 série de 10 repetições do Osotogari. Verificou-se diferença significativa (p < 0,05) entre os sujeitos experientes e iniciantes nos valores de força da célula de manga e célula de gola. Os valores de força da célula da perna e célula do peito não apresentaram diferença significativa. Foi observado média correlação linear entre os valores de pico da força da célula de manga e de gola, que pode ser explicado pelo sincronismo temporal e ritmo que é empregado pelas duas mãos. Foi verificado que há um instante ideal para aplicar a força para se obter um melhor desempenho na execução do golpe. A utilização do dummy tem o intuito de suprir a ... (Resumo completo, clicar acesso eletrônico abaixo) / Judo is a worldwide practiced sport which requires physical fitness for better performance. For the fulfilment of the techniques, it is necessary the coordination of lower and inferior limbs, as well as the synchronization of power delivered by the limbs to achieve efficiency on the gesture. The objective of the present study was to develop an equipment for the performance evaluation of the judo technique Osotogari during uchikomi training, through the behavior of strength signals. The device had 4 load cells placed on four locations of the uke’s body (one who receives the technique) on the tori (one who performs the technique) while applying the technique. The device as built based on a dummy, with one load cell placed on the left side of the chest, other on the back side of the right thigh. The dummy was dressed in a adapted kimono, that received a load cell on the right sleeve and another one on the left side collar. 12 subjects of right side dominance took part on the survey, 7 of them were beginners and 5 were experienced. Each of these subjects performed 1 serie of 10 repetitions of Osotogari. A significant difference was observed between experienced subjects and beginners for the sleeve and the collar load cells data. In the other hand, no significant difference was observed on the chest and thigh load cells. Moderate linear correlation was observed between peak force data of the sleeve and collar load cells, which can be explained by the hands’ temporal synchronization and rhythm. It was observed that there is an ideal moment to apply strength when performing the technique, in order to achieve better performance. The dummy is intended to meet the need for more practical performance analysis methods, contributing this way to the advance in athletes training
15

Medida de torque na articulação do joelho através de dinamômetro isométrico de baixo custo

Leme, Gustavo Pompêo de Camargo [UNESP] 30 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-30Bitstream added on 2014-06-13T18:34:51Z : No. of bitstreams: 1 leme_gpc_me_guara.pdf: 1562060 bytes, checksum: 7323a0cc788cf41c21eee8a3395de5bc (MD5) / O constante aumento no número de praticantes de atividade física, muitos deles sem a devida orientação, vem fazendo com que a incidência de lesões relacionadas ao esporte também cresça. Exercícios físicos realizados com sobrecarga e sem a periodização correta podem acarretar desequilíbrios musculares importantes, modificando a biomecânica normal do praticante, o que acaba impondo ao corpo cargas excessivas e muitas vezes lesivas. Acompanhando essa evolução, a medicina esportiva juntamente com a engenharia biomédica tem avançado muito no que diz respeito à tecnologia para avaliar e quantificar inúmeras variáveis do desempenho humano. As avaliações musculares estão certamente entre as mais comuns e mais utilizadas pelos profissionais da área da reabilitação esportiva. Porém o dinamômetro isocinético que é o dispositivo mais indicado para tais avaliações é um equipamento de difícil acesso, tanto pelo alto custo quanto pela dificuldade de portabilidade. Com isso há necessidade da busca por dispositivos com boa confiabilidade, com preço acessível e que possam gerar dados quantitativos a respeito do desempenho muscular. O objetivo desse trabalho foi desenvolver um dinamômetro isométrico digital da articulação do joelho adaptando uma célula decarga de tração e compressão a uma cadeira extensora utilizada em academias. Após o desenvolvimento do dinamômetro foram realizadas avaliações musculares em 20 voluntários do sexo masculino, com idade entre 18 e 19, sem história prévia de lesões nos membros inferiores. Com os dados obtidos foi possível avaliar o equilíbrio muscular entre os músculos extensores e flexores do joelho dos voluntários, cumprindo assim o objetivo inicial proposto na idealização desse projeto / The constant increase in the number of physically active, many of them without proper guidance, is causing the number of sports-related injuries also grow. Exercises performed with overload and without the correct periodization can cause significant muscle imbalances, modifying the normal biomechanics of the practitioner, which ends up imposing excessive loads on the body and often detrimental. Following this trend, the sports medicine with biomedical engineering has advanced greatly in regard to technology toassess and quantify several variables of human performance. Muscle assessments are certainly among the most common and most used by professionals in the sports rehabilitation. But the isokinetic dynamometer that is most indicated device for those evaluations is a difficult equipment to access, both the high cost and the difficulty of portability. Thus there is need to search for devices with good reliability, with affordable price and that can generate quantitative data regarding the muscle performance. The objective of this study was todevelop a digital isometric dynamometer for the knee joint adapting a tension and compression load cell to a knee extension chair used in gyms. After the development of the dynamometer 20 healthy male volunteers, aged between 18 and 19, with no history of lower limb injuries, had muscle evaluated.With the data obtained it was possible to evaluate the muscle balance between the extensor and flexor muscles of vonlunteers knees, thus fulfilling the initial proposed objective of this project
16

Confiabilidade intraexaminador na medidade força muscular isométrica da musculatura inversora e eversora do tornozelo utilizando o dinamômetro manual em voluntários saudáveis / Intraexaminer reliability of isometric ankle inversion and eversion-strength measurement using hand dynamometer in healthy volunteers

Serafim, Roberto Marsaioli, 1970- 12 July 2011 (has links)
Orientadores: José Martins Filho, Roberto Teixeira Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-20T03:33:35Z (GMT). No. of bitstreams: 1 Serafim_RobertoMarsaioli_M.pdf: 846829 bytes, checksum: 43f38782b5683de6c685ada47b242bf7 (MD5) Previous issue date: 2011 / Resumo: O estudo foi desenhado para investigar a confiabilidade intraexaminador da medida da força muscular isométrica da musculatura inversora e eversora do tornozelo, utilizando o dinamômetro manual Lafayette, em voluntários jovens saudáveis. Vinte voluntários (18-21 anos de idade) foram submetidos a três avaliações consecutivas de força isométrica de ambos (direito e esquerdo) inversores e eversores de tornozelo, medidas em três ocasiões diferentes com 48hs de intervalo. Os voluntários eram saudáveis, sem história de lesão prévia de tornozelo ou déficit neuro muscular. As medidas foram realizadas com a solicitação de força máxima. Dados foram analisados comparando tanto a média de cada dia como o máximo do valor obtido em cada dia. A confiabilidade da medida foi avaliada calculando-se o Coeficiente de Correlação Intraclasse (ICC). Resultados: O ICC intraexaminador para força máxima na inversão do tornozelo direito e esquerdo foi 0.90 e 0.87, respectivamente. O ICC intraexaminador para força máxima na eversão do tornozelo direito e esquerdo variou de 0.79 a 0.86 e de 0.88 a 0.93, respectivamente. Resultados semelhantes foram obtidos comparando a média de valores para cada dia. Nossos resultados indicam que o uso do dinamômetro manual da marca Lafayette é confiável e pode ser útil para avaliar a extensão do déficit de força muscular nas lesões de tornozelo, assim como a evolução das medidas de força na evolução do tratamento / Abstract: The study was designed to investigate the intratester reliability of isometric ankle inversion- and eversion-strength measurement using Lafayette hand held dynamometer in healthy youngth. Twenty volunteers (18-21 years) were submitted to three consecutive evaluations of both (right and left) ankle inversion- and eversion-strength measurement in three different occasions (48h interval). The volunteers were considered healthy with no previous history of ankle lesion. The volunteers were asked to perform maximum strength in each measurement. Data were analyzed comparing either the mean of each day or the maximum value obtained in each day. Reliability of the measurement was assessed by calculating the intraclass correlation coefficient (ICC). Results: The intratester ICC for maximum strength in right and left ankle inversion was 0.90 and 0.87, respectively. The intratester ICC for maximum strength in right and left ankle eversion ranged from 0.79 to 0.86 and from 0.88 to 0.93, respectively. Similar results were obtained comparing the mean values for each day. Our results indicate that use of the Lafayette hand held dynamometer is reliable and may be useful for evaluating extension of muscle strength deficit in ankle lesions, as well the evolution of treatment / Mestrado / Pediatria / Mestre em Saude da Criança e do Adolescente
17

Medida de torque na articulação do joelho através de dinamômetro isométrico de baixo custo /

Leme, Gustavo Pompêo de Camargo, 1977. January 2013 (has links)
Orientador: José Geraldo T. Brandão / Coorientador: Jose Cláudio Caraschi / Banca: José Elias Tomazini / Banca: Renato José Soares / Resumo: O constante aumento no número de praticantes de atividade física, muitos deles sem a devida orientação, vem fazendo com que a incidência de lesões relacionadas ao esporte também cresça. Exercícios físicos realizados com sobrecarga e sem a periodização correta podem acarretar desequilíbrios musculares importantes, modificando a biomecânica normal do praticante, o que acaba impondo ao corpo cargas excessivas e muitas vezes lesivas. Acompanhando essa evolução, a medicina esportiva juntamente com a engenharia biomédica tem avançado muito no que diz respeito à tecnologia para avaliar e quantificar inúmeras variáveis do desempenho humano. As avaliações musculares estão certamente entre as mais comuns e mais utilizadas pelos profissionais da área da reabilitação esportiva. Porém o dinamômetro isocinético que é o dispositivo mais indicado para tais avaliações é um equipamento de difícil acesso, tanto pelo alto custo quanto pela dificuldade de portabilidade. Com isso há necessidade da busca por dispositivos com boa confiabilidade, com preço acessível e que possam gerar dados quantitativos a respeito do desempenho muscular. O objetivo desse trabalho foi desenvolver um dinamômetro isométrico digital da articulação do joelho adaptando uma célula decarga de tração e compressão a uma cadeira extensora utilizada em academias. Após o desenvolvimento do dinamômetro foram realizadas avaliações musculares em 20 voluntários do sexo masculino, com idade entre 18 e 19, sem história prévia de lesões nos membros inferiores. Com os dados obtidos foi possível avaliar o equilíbrio muscular entre os músculos extensores e flexores do joelho dos voluntários, cumprindo assim o objetivo inicial proposto na idealização desse projeto / Abstract: The constant increase in the number of physically active, many of them without proper guidance, is causing the number of sports-related injuries also grow. Exercises performed with overload and without the correct periodization can cause significant muscle imbalances, modifying the normal biomechanics of the practitioner, which ends up imposing excessive loads on the body and often detrimental. Following this trend, the sports medicine with biomedical engineering has advanced greatly in regard to technology toassess and quantify several variables of human performance. Muscle assessments are certainly among the most common and most used by professionals in the sports rehabilitation. But the isokinetic dynamometer that is most indicated device for those evaluations is a difficult equipment to access, both the high cost and the difficulty of portability. Thus there is need to search for devices with good reliability, with affordable price and that can generate quantitative data regarding the muscle performance. The objective of this study was todevelop a digital isometric dynamometer for the knee joint adapting a tension and compression load cell to a knee extension chair used in gyms. After the development of the dynamometer 20 healthy male volunteers, aged between 18 and 19, with no history of lower limb injuries, had muscle evaluated.With the data obtained it was possible to evaluate the muscle balance between the extensor and flexor muscles of vonlunteers knees, thus fulfilling the initial proposed objective of this project / Mestre
18

Relação entre a força muscular e a constante da curvatura da relação torque-duração do exercício /

Bassan, Natália de Menezes. January 2018 (has links)
Orientador: Camila Coelho Greco / Coorientador: Renato Aparecido Corrêa Caritá / Banca: Fabrizio Caputo / Banca: Luiz Guilherme Antonacci Guglielmo / Banca: Leonardo Coelho Rabello de Lima / Banca: Adalgiso Coscrato Cardozo / Resumo: O objetivo deste estudo foi analisar a relação da quantidade de trabalho acima do torque crítico (W') com a força muscular, a partir da análise do efeito do treinamento unilateral de curta duração, influência da dominância e do nível de força. Participaram deste estudo indivíduos do gênero masculino com idades entre 20 e 35 anos que realizaram os seguintes procedimentos, em dias diferentes: 1) Familiarização ao dinamômetro isocinético, mensuração da espessura muscular (EM), eco intensidade (ECO) e antropometria ; 2) realização das medidas ultrassonográficas (EM e ECO), teste de contrações isométricas máximas para determinação da contração voluntária máxima (CVM) e um teste de contrações isométricas intermitentes, no modo all-out, para determinação do impulso acima do torque final (ITF), o qual representa o W' e do torque final (TF), que representa o torque crítico, dos músculos extensores de joelho (EJ), ambos os testes foram realizados com a EMG de superfície no músculo vasto lateral (VL) para a análise da EMG e root mean square (RMS); 3) Foram realizados os mesmos testes do ítem 2 após 72 h após da última sessão de treinamento. O grupo de treinamento (GT) realizou um programa de treino de força de alta intensidade somente no membro dominante (MD) para os EJ com 2 sessões semanais de treinamento durante 3 semanas. O grupo controle (GC) não realizou o programa de treinamento. Antes e após o período de treinamento foram realizados os mesmos testes do item 2. Todos os testes fo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to analyze the relationship of the amount of work above the critical torque (W ') with the muscular strength, from the analysis of the effect of short duration unilateral training, influence of dominance and level of strength. Participants in this study were male subjects aged 20-35 years who performed the following procedures on different days: 1) Familiarization with the isokinetic dynamometer, muscle thickness (EM), echo intensity (ECO) and anthropometry; 2) ultrasound measurements (MS and ECHO), maximum isometric contraction test for determination of maximal voluntary contraction (MVC) and a test of intermittent isometric all-out contractions for impulse above end test-torque (IET), which represents the W' and the end test-torque (TF), which represents the critical torque of the knee extensor muscles (KE), all tests were performed with surface EMG in the vastus lateralis (VL) muscle for the analysis of EMG and root mean square (RMS), all tests were performed on both limbs; 3) the same tests of item 2 were performed after 72 hours of the last training session. The training group (GT) performed a high intensity strength training program in the dominant limb (DL) for the KE, 2 times per week for 3 weeks. The control group (CG) did not perform the training program. The first and last test period were the tests of item 2. All tests were performed at different times with 72 hours of recovery in one test and another at the same time of day (± 2 h)... (Complete abstract click electronic access below) / Doutor
19

Effects of two periodized training programs : aerobic interval and functional resistance on isokinetic muscle strength, physical fitness and clinical parameters in metabolic syndrome. Non-randomized controlled clinical trial /

Mesa Castrillón, Carlos Iván. January 2017 (has links)
Orientador: Jayme Netto Júnior / Banca: Fabio do Nascimento Bastos / Banca: Fabio Santos de Lira / Resumo: Introdução: A Síndrome Metabólica é uma condição sistêmica relacionada com transtornos musculoesqueléticos. O treinamento aeróbio intervalado é amplamente utilizado como tratamento mas seus efeitos sobre a força muscular e aptidão física, ainda são pouco descritos. Objetivo: Analisar e comparar os efeitos de dois programas periodizados: treinamento aeróbio intervalado e treinamento funcional resistido na força muscular isocinética, aptidão física, e parâmetros clínicos em sujeitos com Síndrome Metabólica. Métodos: 68 participantes com idade entre 35 e 60 anos e diagnóstico de Síndrome Metabólica, foram divididos em três grupos, controle sem intervenção, treinamento aeróbio intervalado e resistido funcional, os quais foram submetidos a programas de exercício periodizado, totalizando 39 sessões. Análise estatística: Utilizou-se análise de covariância (ANCOVA) e Kruskal-Wallis para dados paramétricos e não paramétricos, respectivamente. Resultados: Os grupos aeróbio e resistido melhoraram a força de flexão de joelho. Houve diferenças significativas na agilidade e resistência aeróbia geral incluindo um tamanho de efeito grande que favorece ao grupo aeróbio intervalado. Conclusão: Ambos treinamentos tiveram um tamanho de efeito médio na força de flexão de joelho e efeito baixo na força de extensão. Além disso tiveram grande efeito na agilidade, mas só exercício aeróbio intervalado foi efetivo na melhora da resistência aeróbia geral com tamanho de efeito grande / Abstract: Introduction: Metabolic Syndrome is a systemic condition related to musculoskeletal disorders. Aerobic interval training is widely used as treatment but its effects on muscular strength and musculoskeletal symptoms are still modestly described. Objective: to analyze and to compare the effects of two periodized programs, aerobic interval and functional resistance training on isokinetic muscular strength, physical fitness, and clinical parameters in participants with Metabolic Syndrome. Methods: 68 participants aged 35 and 60 years old, with Metabolic Syndrome diagnostic, were divided in three groups: control with no intervention, aerobic interval and functional resistance training, who were submitted in exercise programs, totalizing 39 sessions. Statistical analysis: We used covariance (ANCOVA) and Kruskal-Wallis analysis for parametric and non-parametric data, respectively. Results: Aerobic and resistance training improved knee flexion muscle strength. There were significant differences in agility and overall aerobic endurance, including a large effect size that favors the interval aerobic group. Conclusion: 16 weeks of either aerobic interval or functional resistance training had a medium effect on knee flexion strength and a low effect on knee extension strength. Both training program had a large effect on agility, but only aerobic interval training was effective to improve general aerobic resistance with a large effect size / Mestre
20

Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd

Penido, Sérgio Milton Martins de Oliveira [UNESP] 30 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-30Bitstream added on 2014-06-13T19:44:08Z : No. of bitstreams: 1 penido_smmo_dr_arafo.pdf: 996491 bytes, checksum: 142106818d9d76c3991a99fe95fe589a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure.

Page generated in 0.0779 seconds