• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 33
  • 28
  • 12
  • 3
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 142
  • 142
  • 33
  • 30
  • 26
  • 22
  • 20
  • 19
  • 18
  • 16
  • 15
  • 15
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Ns Pulse / RF Hybrid Plasmas for Plasma Chemistry and Plasma Assisted Catalysis Applications

Gulko, Ilya Dmitrievich January 2020 (has links)
No description available.
102

Ein Lasersystem für Experimente mit Quantengasen unter Schwerelosigkeit

Schiemangk, Max 29 March 2019 (has links)
Bereits Galilei untersuchte, ob verschiedene frei fallende Körper im Schwerefeld der Erde gleich stark beschleunigt werden, die sogenannte Universalität des freien Falls. Die Genauigkeit der experimentellen Überprüfungen konnte seitdem beständig gesteigert werden. Einen neuen Ansatz, die Messgenauigkeit noch weiter zu verbessern, bilden quantenmechanische Messmethoden, die auf Materiewelleninterferometrie beruhen. Die dabei genutzten Apparaturen verwenden Laserstrahlung zur Kühlung, Manipulation und Detektion der Atome. Ziel der vorliegenden Arbeit war die Entwicklung des Lasersystems für ein neues Experiment, das erstmals Zwei-Spezies-Atominterferometrie (mit Rb & K) in Mikrogravitation demonstrieren soll. Ein Lasersystem, das sowohl die funktionalen Anforderungen als auch die aus dem Einsatz auf dem Katapult des Fallturms resultierenden Anforderung (Volumen < 44 l, Masse < 35 kg und voll funktionsfähig sofort nach einem Katapultstart mit Beschleunigungen von 30 g) erfüllt, wurde funktional konzipiert und mechanisch designt. Zur Demonstration wurde der Rubidium-Teil des Lasersystems funktional sowie mechanisch qualifiziert. Inzwischen wird er routinemäßig für Experimente am Fallturm eingesetzt. Für das Lasersystem wurden kompakte und robuste schmalbandigen Lasermodule entwickelt. Diese liefern bei einer Grundfläche der optischen Bank von nur 10 mm x 50 mm Ausgangsleistungen von bis zu 3,7 W. Am Arbeitspunkt (1 W Ausgangsleistung) besitzen die Strahlquellen Linienbreiten im Bereich von 100 kHz (Lorentz) bzw. 1 MHz (-3 dB, 10 µs). Zum Nachweis der spektralen Stabilität der Lasermodule wurde ein Messverfahrens zur Charakterisierung des Frequenzrauschens freilaufender Laser entwickelt. Dieses basiert auf einer Schwebungsmessung mit anschließender Analyse der Quadraturkomponenten des Signals im Zeitbereich. Durch den Einsatz geeigneter Filter erlaubt es die Unterdrückung der für Diodenlaser typischen Frequenzdrifts. / Galileo, already, investigated whether different free falling bodies in the gravitational field of the Earth are accelerated at the same rate, the so-called universality of the free fall. The accuracy of the experimental tests has been steadily increased ever since. A new approach to further increase the measurement accuracy is provided by quantum mechanical measurements based on matter wave interferometry. The apparatuses used for this purpose employ laser radiation for cooling, manipulation, and detection of the atoms. The aim of this thesis’ work was the development of the laser system for a new experiment intended to demonstrate two-species atom interferometry (utilizing Rb & K) in microgravity for the first time. A laser system, which fulfills the functional requirements as well as the requirements resulting from the deployment on the catapult of the drop tower (volume < 44 l, mass < 35 kg, and fully functional immediately after a catapult launch with accelerations of 30 g), has been functionally conceived and mechanically designed. For demonstration, the rubidium part of the laser system was functionally and mechanically qualified. By now, it is routinely used for experiments at the drop tower. For the laser system, compact and robust spectrally narrow laser modules have been developed. These provide an output power up to 3.7 W at a footprint of the optical bench of only 10 mm × 50 mm. At the operating point (1 W output power), the radiation sources exhibit linewidths in the range of 100 kHz (Lorentzian) and 1 MHz (−3 dB, 10 μs). To validate the spectral stability of the laser modules a measuring method for the characterization of the frequency noise of free-running lasers has been developed. This method is based on a beat note measurement with subsequent analysis of the quadrature components of the signal in the time domain. By utilizing appropriate filters, it allows for the suppression of the frequency drifts that are typical for diode lasers.
103

Implementation of optical feedback interferometry for sensing applications in fluidic systems / Implémentations de l'interférométrie par réinjection optique pour les applications de métrologie dans les systèmes fluidiques

Ramírez Miquet, Evelio Esteban 29 September 2016 (has links)
L'interférométrie par réinjection optique est une technique de mesure dont l'implémentation pour l'interrogation de systèmes fluidiques est assez récente. Le principe de mesure est basé sur la perturbation des paramètres d'émission du laser induite par la réinjection dans la cavité laser de lumière rétro-diffusée par une cible distante. La technique permet le développement de capteurs compact et non-invasifs qui mesurent différents paramètres liés aux déplacements de la cible. En particulier, les interféromètres par réinjection optique prennent avantage de l'effet Doppler pour mesurer la vitesses de traceurs dans les liquides en écoulement. Cet aspect important de la technique de réinjection optique la rend adaptée à une grande variété d'applications dans les domaines du génie chimique et du biomédical où un contrôle des écoulements est requis. Cette thèse présente l'implémentation de capteur basés sur la réinjection optique pour différents systèmes fluidiques où la vitesse locale d'écoulement ou le débit sont directement mesurés. Nous présentons une étude centrée sur les applications où la réinjection optique est utilisée pour la mesure du débit à la micro-échelle avec en particulier une analyse de la robustesse des méthodes de traitement du signal propres aux régimes de diffusion simple et de diffusion multiple. Par ailleurs, nous présentons des résultats expérimentaux de mesures ex vivo où le capteur par réinjection optique est proposé comme alternative pour la myographie. Nous présentons également une implémentation temps réel pour l’estimation du débit instantané d'écoulements dynamiques dans une configuration milli-fluidique. Un système semi-automatisé de détection de particule unique dans un micro-canal est proposé et démontré. Enfin, un capteur basé sur la réinjection optique est implémenté pour la caractérisation des interactions entre deux fluides immiscibles en écoulement à micro-échelle et les mesures réalisées sont comparées à un modèle développé afin de décrire le comportement hydrodynamique des deux fluides dans un micro-réacteur. Le manuscrit décrit une contribution importante pour l'implémentation de capteur par réinjection optique pour des applications fluidiques et en particulier micro-fluidiques. Il présente également des résultats expérimentaux remarquables qui ouvrent de nouveaux horizons pour l'interférométrie à réinjection optique. / Optical feedback interferometry is a sensing technique with relative recent implementation for the interrogation of fluidic systems. The sensing principle is based on the perturbation of the laser emission parameters induced by the reinjection in the laser cavity of light back-scattered from a distant target. The technique allows for the development of compact and noninvasive sensors that measure various parameters related to the motion of moving targets. In particular, optical feedback interferometers take advantage of the Doppler effect to measure the velocity of tracers in flowing liquids. These important features of the optical feedback interferometry technique make it wellsuited for a variety of applications in chemical engineering and biomedical fields, where accurate monitoring of the flows is needed. This thesis presents the implementation of optical feedback interferometry based sensors in multiple fluidic systems where local velocity or flow rate are directly measured. We present an application-centered study of the optical feedback sensing technique used for flow measurement at the microscale with focus on the reliability of the signal processing methods for flows in the single and the multiple scattering regimes. Further, we present experimental results of ex vivo measurements where the optical feedback sensor is proposed as an alternative system for myography. In addition we present a real-time implementation for the assessment of non-steady flows in a millifluidic configuration. A semi-automatized system for single particle detection in a microchannel is proposed and demonstrated. Finally, an optical feedback based laser sensor is implemented for the characterization of the interactions between two immiscible liquid-liquid flowing at the microscale, and the measurement is compared to a theoretical model developed to describe the hydrodynamics of both fluids in a chemical microreactor. The present manuscript describes an important contribution to the implementation of optical feedback sensors for fluidic and microfluidic applications. It also presents remarkable experimental results that open new horizons to the optical feedback interferometry.
104

Analysis of the different signal acquisition schemes of an optical feedback based laser diode interferometer / Analyse des différents schémas d’acquisition d’un capteur interférométrique par réinjection optique dans une diode laser

Al Roumy, Jalal 20 September 2016 (has links)
Le phénomène d’interférométrie par réinjection optique se produit lorsqu’une portion de la puissance optique du laser est rétrodiffusée par une cible distante puis réinjectée dans la cavité laser ce qui affecte les propriétés d’émission du laser (fréquence et puissance en particulier). Ce principe résulte alors en un capteur interférométrique compact, auto-aligné et sans contact. Des applications récentes des capteurs par réinjection optique dans les domaines de la microfluidique et de l’acoustique ont montré des résultats prometteurs et ouvert de nouveaux domaines de recherche. Pourtant, dans le cadre de ces applications, l’amplitude du signal est extrêmement faible à cause de la faible amplitude des variations de la puissance rétrodiffusée qui est mesurée. Dans cette thèse, un modèle analytique décrivant la dépendance de l’amplitude du signal issu d’une diode laser monomode au courant d’injection et à la température est développé à partir des équations d’évolution de Lang et Kobayashi. Le modèle a été développé pour toutes les méthodes connues d’acquisition du signal interférométrique par réinjection optique : par la photodiode de monitoring incluse dans le boîtier de la diode laser, par la captation de la puissance optique au moyen d’un photodétecteur externe et par l’amplification de la tension aux bornes de la diode laser elle-même. Le modèle démontre que les signaux des photodiodes et de la tension sont liés à l’efficacité externe de la diode laser, qui elle-même est fonction du courant injecté et de la température. Qui plus est, le modèle prédit une évolution très différente de l’amplitude de ces différents signaux en fonction du courant d’injection ou de la température. Un résultat remarquable, confirmé par une campagne de mesures pour ces trois types de signaux sur une large plage de courants d’injection et de températures. Ainsi ce modèle simple permet une compréhension nouvelle des stratégies de polarisation très différentes de la diode laser permettant d’obtenir une sensibilité optimale du capteur dans les différents schémas d’acquisition du signal. Par ailleurs, les relations entre la phase et l’amplitude des signaux issus des photodiodes externes et de monitoring ont été étudiées sur le plan théorique et expérimental ce qui a permis de révéler des résultats inattendus. À partir du modèle et basé sur des observations expérimentales, une étude critique a été menée sur l’impact de la combinaison des trois signaux dans la stratégie de traitement du signal afin d’améliorer la sensibilité du capteur aux réinjections optiques de faible amplitude. / The optical feedback interferometry phenomenon occurs when a portion of the output optical power is back-scattered from a remote target and coupled into the laser cavity to vary the laser’s emission properties (frequency and power mostly). Thus, this scheme results in a compact, self-aligned and contact-less interferometric sensor. Recent applications of optical feedback interferometer in the domains of microfluidics or acoustics have shown promising results and open new fields of researches. However in these applications, the amplitude of the sensing signal is extremely small due to the weakness of the backscattered power changes that are measured. In this thesis, an analytical model that describes the laser injection current and temperature dependence of the optical feedback interferometry signal strength for a single-mode laser diode has been derived from the Lang and Kobayashi rate equations. The model has been developed for all the known signal acquisition methods of the optical feedback interferometry scheme: from the package included monitoring photodiode, by collection of the laser power with an external photodetector and by amplification of the variations in the laser junction voltage. The model shows that both the photodiodes and the voltage signals strengths are related to the laser slope efficiency, which itself is a function of the laser injection current and of the temperature. Moreover, the model predicts different behaviors of the photodiodes and the voltage signal strengths with the change of the laser injection current and the temperature; an important result that has been proven by conducting measurements on all three signals for a wide range of injection current and temperature. Therefore, this simple model provides important insights into the radically different biasing strategies required to achieve optimal sensor sensitivity for the different interferometric signal acquisition schemes. In addition, the phase and amplitude relationships between the external and the in-package photodiode signals have been investigated theoretically and experimentally demonstrating unexpected results. Based on our model and on experimental observations, a critical study has been performed on the impact of the combination of the three signals in the signal processing strategy in order to improve the sensor sensibility to low amplitude optical feedback.
105

Thermal Management, Beam Control,and Packaging Designs For High Power

Chung, Te-yuan 01 January 2004 (has links)
Several novel techniques for controlling, managing and utilizing high power diode lasers are described. Low pressure water spray cooling for a high heat flux system is developed and proven to be an ideal cooling method for high power diode laser arrays. In order to enable better thermal and optical performance of diode laser arrays, a new and simple optical element, the beam control prism, is invented. It provides the ability to accomplish beam shaping and beam tilting at the same time. Several low thermal resistance diode packaging designs using beam control prisms are proposed, studied and produced. Two pump cavity designs using a diode laser array to uniformly pump rod shape gain media are also investigated.
106

Mise au point de la fluorescence induite par diode laser résolue en temps : application à l'étude du transport des atomes de tungstène pulvérisés en procédé magnétron continu ou pulsé haute puissance / Development of time resolved diode laser induced fluorescence : Application for study of W atoms transport in direct current and pulsed magnetron discharge

Désécures, Mikaël 20 November 2015 (has links)
La pulvérisation cathodique magnétron est un procédé plasma très répandu dans l'industrie pour le dépôt de couches minces. Néanmoins, les exigences des nouvelles applications nécessitent de mieux comprendre, contrôler et maîtriser les processus fondamentaux gouvernant le transport de la matière pour optimiser le procédé. Ce travail de thèse porte sur l'étude du transport des atomes pulvérisés de tungstène (W) en décharge magnétron continu (DC direct current) et pulsée haute puissance (HiPIMS_high power impulse magnétron sputtering). La fluorescence induite par diode laser (TD-LIF) a été mise au point afin de mesurer les fonctions de distribution en vitesse des atomes W pulvérisés. Les mesures ont été calibrées par absorption laser et validées en corrélant avec les vitesses de dépôt. En procédé DC, l'étude de l’influence des paramètres de la décharge (puissance, tension, mélange gazeux Ar/He, distance par rapport à la cible, etc.) a mis en évidence l'évolution spatiale des régimes de transport balistique (atomes énergétiques), diffusif (atomes thermalisés), et mixte (balistique+diffusif). Pour l'étude du procédé HiPIMS, le plasma pulsé a nécessité de développer la TD-LIF résolue en temps (TR-TDLIF). Le degré de liberté supplémentaire qu'offre la dimension temporelle du plasma HiPIMS a permis de mieux comprendre le transport mixte qui représente le cas le plus compliqué. En effet, cela a permis de mesurer la cinétique du transport des atomes pulvérisés en ayant la possibilité de séparer les temps caractéristiques des différents processus / Magnetron sputter deposition is an established and widely used method for the growth of thin films. Nevertheless, the high level of expectations regarding new applications require a better understanding, controlling, mastering of basic processes governing atoms transport in the view of process optimization. This work consist in the study of transport of sputtered W atoms in direct current and high power impulse magnetron discharges (DC and HiPIMS). A tunable diode laser induced fluorescence technique (TD-LIF) has been developed, in order to measure W sputtered atom velocity distribution function. Measurements were calibrated using laser absorption and were corroborated by deposition rate. In DC, the study of the influence of discharge parameters (power, voltage, Ar/He gas mixture, and distance from target, etc.) highlighted spatial evolution of different regimes of transport: ballistic (energetic atoms), diffusive (thermalized atoms), and mixed (ballistic + diffusive). In HiPIMS, pulsed plasma required to develop a time resolved TD-LIF technique (TR-TDLIF). The additional degree of freedom, given by time dimension allowed for a better understanding of mixed transport which represents the most complicated situation. This technique allowed to measure the kinetic of sputtered W atoms while at the same time providing the possibility to separate characteristic time scales of different processes
107

Sources à diode laser auto-organisables - Nonlinearités dans des nanostructures semi-conductrices

Dubreuil, Nicolas 28 July 2010 (has links) (PDF)
La première partie du manuscrit est consacrée au fonctionnement de sources à diode laser en montage de type cavité étendue et qui intègre un filtre holographique. Ce filtre intra-cavité est dynamique est constitué de l'association d'un matériau photoréfractif et d'un réflecteur. Nous montrons que ce filtre est équivalent à un filtre Fabry-Perot dont l'un des miroirs est constitué par un réseau de Bragg photoréfractif enregistré par la structure de modes du laser. Ses caractéristiques sont décrites en détail. Une brève analyse de stabilité d'un laser auto-organisable illustre le processus de sélection entre les modes, induit par le filtre Fabry-Perot photoréfractif. Nous avons alors étudié des fonctionnements de sources à diode laser montée en cavité étendue utilisant comme réflecteur distant un filtre Fabry-Perot photoréfractif. Dans le cas des diodes laser qualifiées de limitée par diffraction, où l'émission laser est supportée par un seul mode transverse, cette configuration originale force l'oscillation de la source sur un seul mode longitudinal et ce, sur une large plage de courant d'injection. Ce comportement a été démontré pour des longueurs d'onde de fonctionnement allant de 630 à 1550 nm et des puissances de sortie variant de quelques dizaines de milliWatt au Watt. Enfin, nous avons démontré qu'un tel filtre dynamique utilisé avec des diodes laser à ruban large, supportant plusieurs modes transverse, introduit également des pertes sélectives sur la structure transverse des modes. L'application dans ce dernier cas est l'amélioration de la brillance de sources à diode laser de puissance. Enfin, nous présentons le fonctionnement original d'une source à diode laser accordable dont la longueur d'onde de fonctionnement est fixée par l'injection optique temporaire d'un faisceau issu d'un laser maître. Cette source présente la particularité de disposer dans sa cavité d'un milieu holographique dynamique de type photoréfractif qui lui permet, après arrêt de l'injection, de conserver un fonctionnement à la longueur d'onde préalablement imposée par le laser maître. En utilisant un laser maître accordable en longueur d'onde, nous avons réalisé l'adressage optique d'une telle source suivant un peigne de longueurs d'onde quasi périodique. La seconde partie du manuscrit traite des études sur le renforcement des interactions nonlinéaires dans des milieux micro-structurés en semi-conducteurs. La première étape a nécessité le développement complet d'une source OPO accordable en longueur d'onde et délivrant des impulsions picosecondes. Nous rapportons la première démonstration expérimentale et quantitative sur le lien entre la propagation d'une impulsion en régime de lumière lente et l'exaltation des nonlinéarités. Nous avons en particulier étudié les phénomènes d'absorption à deux photons (TPA) et d'auto-modulation de phase induits par les effets Kerr optique et de réfraction par les porteurs libres (FCR) générés par TPA. Par un ajustement de nos courbes expérimentales, sans paramètre ajustable (en s'appuyant sur la valeur de la vitesse de groupe mesurée en régime de propagation linéaire), nous avons démontré de manière quantitative l'effet de l'exaltation des nonlinéarités par l'effet du ralentissement de la lumière. Parallèlement, nous avons initié une étude consacrée à la diffusion Raman stimulée dans des nano-structures semi-conductrices. Nous avons démontré, dans des nanoguides de silicium sur isolant, une saturation du facteur d'amplification Raman par l'élargissement spectral des impulsions pompe par des effets d'automodulation de phase nonlinéaire. Enfin, nous présentons nos résultats expérimentaux sur le fonctionnement d'une microcavité doublement résonnante en régime de diffusion Raman stimulée.
108

Study of the coherent effects in rubidium atomic vapor under bi-chromatic laser radiation / Etude des effets cohérents dans la vapeur de rubidium atomique sous irradiation laser bi-chromatique

Mirzoyan, Rafayel 04 June 2013 (has links)
L’effet de la transparence induite électromagnétiquement est observée à l’aidede cellules nanométriques et de cellules micrométriques. La résonance EIT avec de bons paramètres (fort contraste et faible largeur du signal à mi-hauteur) est obtenue dans des cellules étroites. L' éclatement de la résonance EIT dans un champ magnétique est observé pour les raies D1 du 85Rb et 87Rb. Nous présentons un modèle théorique qui explique la dépendance du déplacement en fréquence des composantes de la résonance EIT en fonction de l’intensité du champ magnétique. Les résultats théoriques et expérimentaux sont comparés et démontrent un bon accord.Pour la première fois une résonance de type N est obtenue dans une micro-cellule. Nous obtenons de bons paramètres (fort contraste et faible largeur du signal à mi-hauteur) dela résonance N à l’aide d’une micro-cellule. Cela nous permet d’observer le comportement d’une résonance N dans un champ magnétique. L’éclatement de la résonance N dans unchamp magnétique est observé pour les raies D1 du 85Rb et 87Rb. Nous présentons les calculs théoriques qui expliquent la dépendance du déplacement en fréquence des composantes dela résonance N en fonction de l’intensité du champ magnétique. Les résultats théoriques et expérimentaux sont comparés et démontrent un bon accord. Le comportement de la résonance N en régime hyperfin Paschen-Back est présenté et expliqué. Enfin une comparaison des résonances EIT et N est faite / The effect of electromagnetically induced transparency is observed, using nanocelland microcell. The EIT-resonance with good parameters (high contrast and small FWHM) is obtained in thick cells. The EIT-resonance splitting in magnetic field is observed for the cases of D1-line of 85Rb and 85Rb. The theoretical model, explaining the EIT-resonance components frequency shift dependence on magnetic field strength is presented. The theoretical and experimental results are compared and good agreement is shown. Also the EIT-resonance behavior in hyperfine Paschen-Back regime is presented and explained. For the first time the N-type resonance in microcell is observed. Good parameters of theN-type resonance in microcell are obtained. It allows us to observe the N-type resonance behavior in magnetic field. The N-resonance splitting in magnetic field is observed for the cases of 85Rb and 85Rb. The theoretical calculations of the N-resonance components frequency shift dependence on magnetic field is presented. The theoretical and experimental results are compared and good agreement is shown. Also the N-resonance behavior in hyperfine Paschen-Back regime is presented and explained. Simultaneous observation of N- and EIT-resonance is shown. Comparison of EIT- and N-resonance is made
109

Study of the coherent effects in rubidium atomic vapor under bi-chromatic laser radiation

Mirzoyan, Rafayel 04 June 2013 (has links) (PDF)
The effect of electromagnetically induced transparency is observed, using nanocelland microcell. The EIT-resonance with good parameters (high contrast and small FWHM) is obtained in thick cells. The EIT-resonance splitting in magnetic field is observed for the cases of D1-line of 85Rb and 85Rb. The theoretical model, explaining the EIT-resonance components frequency shift dependence on magnetic field strength is presented. The theoretical and experimental results are compared and good agreement is shown. Also the EIT-resonance behavior in hyperfine Paschen-Back regime is presented and explained. For the first time the N-type resonance in microcell is observed. Good parameters of theN-type resonance in microcell are obtained. It allows us to observe the N-type resonance behavior in magnetic field. The N-resonance splitting in magnetic field is observed for the cases of 85Rb and 85Rb. The theoretical calculations of the N-resonance components frequency shift dependence on magnetic field is presented. The theoretical and experimental results are compared and good agreement is shown. Also the N-resonance behavior in hyperfine Paschen-Back regime is presented and explained. Simultaneous observation of N- and EIT-resonance is shown. Comparison of EIT- and N-resonance is made
110

Analyse par spectrométrie de masse des antibiotiques vétérinaires liés à l’élevage porcin

Solliec, Morgan 08 1900 (has links)
L’élevage des porcs représente une source importante de déversement d’antibiotiques dans l’environnement par l’intermédiaire de l’épandage du lisier qui contient une grande quantité de ces molécules sur les champs agricoles. Il a été prouvé que ces molécules biologiquement actives peuvent avoir un impact toxique sur l’écosystème. Par ailleurs, elles sont aussi suspectées d’engendrer des problèmes sanitaires et de contribuer à la résistance bactérienne pouvant mener à des infections difficilement traitables chez les humains. Le contrôle de ces substances dans l’environnement est donc nécessaire. De nombreuses méthodes analytiques sont proposées dans la littérature scientifique pour recenser ces composés dans plusieurs types de matrice. Cependant, peu de ces méthodes permettent l’analyse de ces contaminants dans des matrices issues de l’élevage agricole intensif. Par ailleurs, les méthodes analytiques disponibles sont souvent sujettes à des faux positifs compte tenu de la complexité des matrices étudiées et du matériel utilisé et ne prennent souvent pas en compte les métabolites et produits de dégradation. Enfin, les niveaux d’analyse atteints avec ces méthodes ne sont parfois plus à jour étant donné l’évolution de la chimie analytique et de la spectrométrie de masse. Dans cette optique, de nouvelles méthodes d’analyses ont été développées pour rechercher et quantifier les antibiotiques dans des matrices dérivées de l’élevage intensif des porcs en essayant de proposer des approches alternatives sensibles, sélectives et robustes pour quantifier ces molécules. Une première méthode d’analyse basée sur une technique d’introduction d’échantillon alternative à l’aide d’une interface fonctionnant à l’aide d’une désorption thermique par diode laser munie d’une source à ionisation à pression atmosphérique, couplée à la spectrométrie de masse en tandem a été développée. L’objectif est de proposer une analyse plus rapide tout en atteignant des niveaux de concentration adaptés à la matrice étudiée. Cette technique d’analyse couplée à un traitement d’échantillon efficace a permis l’analyse de plusieurs antibiotiques vétérinaires de différentes classes dans des échantillons de lisier avec des temps d’analyse courts. Les limites de détection atteintes sont comprises entre 2,5 et 8,3 µg kg-1 et sont comparables avec celles pouvant être obtenues avec la chromatographie liquide dans une matrice similaire. En vue d’analyser simultanément une série de tétracyclines, une deuxième méthode d’analyse utilisant la chromatographie liquide couplée à la spectrométrie de masse à haute résolution (HRMS) a été proposée. L’utilisation de la HRMS a été motivée par le fait que cette technique d’analyse est moins sensible aux faux positifs que le triple quadripôle traditionnel. Des limites de détection comprises entre 1,5 et 3,6 µg kg-1 ont été atteintes dans des échantillons de lisier en utilisant un mode d’analyse par fragmentation. L’utilisation de méthodes de quantifications ciblées est une démarche intéressante lorsque la présence de contaminants est suspectée dans un échantillon. Toutefois, les contaminants non intégrés à cette méthode d’analyse ciblée ne peuvent être détectés même à de fortes concentrations. Dans ce contexte, une méthode d’analyse non ciblée a été développée pour la recherche de pharmaceutiques vétérinaires dans des effluents agricoles en utilisant la spectrométrie de masse à haute résolution et une cartouche SPE polymérique polyvalente. Cette méthode a permis l’identification d’antibiotiques et de pharmaceutiques couramment utilisés dans l’élevage porcin. La plupart des méthodes d’analyse disponibles dans la littérature se concentrent sur l’analyse des composés parents, mais pas sur les sous-produits de dégradation. L’approche utilisée dans la deuxième méthode d’analyse a donc été étendue et appliquée à d’autres classes d’antibiotiques pour mesurer les concentrations de plusieurs résidus d’antibiotiques dans les sols et les eaux de drainage d’un champ agricole expérimental. Les sols du champ renfermaient un mélange d’antibiotiques ainsi que leurs produits de dégradation relatifs à des concentrations mesurées jusqu’à 1020 µg kg-1. Une partie de ces composés ont voyagé par l’intermédiaire des eaux de drainage du champ ou des concentrations pouvant atteindre 3200 ng L-1 ont pu être relevées. / Swine production is a major source of antibiotic release into the environment via manure spreading on agricultural fields. It has been shown that these biologically active compounds may have a toxic impact on ecosystems. Moreover, they are also suspected to cause health problems and contribute to bacterial resistance that could lead to difficult-to-treat infections in humans. Therefore, control of these substances in the environment is necessary. Several analytical methods are proposed in the scientific literature to identify these compounds in various matrices. However, few of these methods allowed the analysis of these contaminants in matrices derived from intensive livestock farming. Furthermore, the analytical methods available are often subject to false positives, given the complexity samples and the equipment used and do not take into account the metabolites and degradation products. Finally, concentration levels reached with these methods are sometimes outdated since the evolution of analytical chemistry and mass spectrometry. In this context, new analytical methods have been developed to investigate and quantify the antibiotics derived from swine husbandry to propose alternative, sensible, selective and robust approaches to quantify these molecules. A first analytical method has been proposed based on an alternative sample introduction technique using the laser diode thermal desorption interface with an atmospheric pressure chemical ionization source coupled to tandem mass spectrometry. The objective was to provide a simpler and faster analysis while reaching levels suitable for the studied matrix. This alternative sample introduction method coupled with an efficient sample processing allowed the analysis of several classes of veterinary antibiotics in swine manure in a short analysis time. Detection limits ranged between 2.5 and 8.3 µg kg-1 and are comparable with those obtained with liquid chromatography in a similar matrix. In order to simultaneously analyze a series of tetracyclines, a second analytical method using liquid chromatography coupled to high-resolution mass spectrometry (HRMS) was proposed. The use of HRMS was motivated by the fact that this mass spectrometer is less sensitive to false positive that the traditional triple quadrupole given the complexity of the studied matrix. Detection limits between 1.5 and 3.6 µg kg-1 have been achieved in swine manure using a fragmentation analysis mode to avoid false positives. Targeted screening methods are interesting approaches when contaminants are suspected to be present in a sample. However, a non-included contaminant in this targeted analysis method could not been detected even at a high concentration. In this context, a non-target compound screening method focused on veterinary pharmaceutical compounds in swine manure was developed using liquid chromatography coupled to high-resolution mass spectrometry. A polymeric SPE cartridge was used to collect polar compounds including pharmaceuticals prior analysis. This method allowed the identification of antibiotics and pharmaceuticals of commonly used in swine farming. Most of the analytical methods available in the literature focus on parent compounds, regardless degradation products. The approach used in the second method of analysis was applied and extended to other classes of antibiotics to measure concentrations of several antibiotic residues in soils and drainage waters of an experimental agricultural field. Field soil contained a mixture of antibiotics and their related degradation products with concentrations measured up to 1020 µg kg-1. Some of these compounds have migrated through the field via drainage waters wherein concentrations up to 3200 ng L-1 were observed.

Page generated in 0.0629 seconds