• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 33
  • 28
  • 12
  • 3
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 142
  • 142
  • 33
  • 30
  • 26
  • 22
  • 20
  • 19
  • 18
  • 16
  • 15
  • 15
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Développement de diodes laser émettant à 975nm de très forte puissance, rendement à la prise élevé et stabilisées en longueur d’onde pour pompage de fibres dopées et réalisation de lasers à fibre / Development of high-power laser diodes emitting at 975nm with enhanced wall-plug efficiency and wavelength stabilization for optical pumping of doped fibers and realization of fiber lasers

Mostallino, Roberto 05 September 2018 (has links)
Cette thèse CIFRE adresse le développement de diodes laser, émettant à 975nm, de très forte puissance, rendement à la prise élevé, et stabilisées en longueur d’onde pour pompage de fibres dopées Er/Yb et réalisation de lasers à fibre. La thèse a été développée dans le cadre d’un partenariat étroit entre le Laboratoire IMS, le GIE III-V Lab, principal fondeur français de composants à semiconducteurs III-V pour des applications électroniques et photoniques, et THALES Research & Technology à Palaiseau en région parisienne. Un travail en profondeur de caractérisation et d’analyse a porté sur les aspects thermiques qui contribuent, en particulier,à limiter les niveaux de puissance optique de sortie. Dans ce cadre, nous avons réalisé un ensemble de caractérisations complémentaires au GIE III-V lab et à l’IMS nous permettant d’envisager des solutions correctives d’optimisation technologique portant en particulier sur la profondeur de gravure définissant la largeur de la zone d’émission et la nature du substrat dissipateur. Ces solutions ont été proposées à partir de modélisations physiques mises en oeuvre avec un simulateur dédié, propriété de III-V Lab et de simulations par éléments finis thermiques et thermomécaniques (approche multiphysique) de la structure microassemblée définitive. Ces travaux se sont prolongés par la fabrication et la caractérisation électro-optique et thermique de plusieurs structures verticales : LOC (Large Optical Cavity), SLOC (Super Large OpticalCavity) et AOC (Asymetrical Optical Cavity). Les diodes laser de type LOC et SLOC sont stabilisées en longueur d’onde en intégrant un réseau de Bragg (DFB). Une puissance optique de 8W avec une efficacité de 60% a été obtenue ; ce qui permet de situer ces travaux à l’état de l’art international notamment vis-à-vis de ceux publiés par l’Institut Ferdinand-Braun.L’originalité des travaux menés dans cette thèse nous a permis d’avoir accès à une bourse du Cluster européen « Laserlab » (The Integrated Initiative of European Laser Research Infrastructures), pour conduire des campagnes d’expérimentation à l’Institut Max Born à Berlin dans le groupe du Dr J.W. Tomm. Les travaux ont porté sur la caractérisation thermique de ces diodes laser de forte puissance émettant à 975nm, à double hétérostructure symétrique et asymétrique (SLOC et AOC), en utilisant des techniques complémentaires (microphotoluminescence,photoluminescence résolue en temps, spectroscopie de photocourant et mesures L-I pulsées) et permettant d’évaluer le type de contraintes résiduelles apportées par les étapes de report de la diode Laser ainsi que la cinétique de dégradation catastrophique de type COD. / This PhD addresses the development of high-power laser diodes emitting at 975nm withhigh efficiency and wavelength stabilized using a Bragg grating. This thesis was conducted in the framework of a close partnership between IMS Laboratory, the GIE III-V lab, who is themain French founder of III-V semiconductor devices for electronic and photonic applications,and THALES Research & Technology in Palaiseau. An in-depth characterization and analysiswork has addressed thermal aspects that contribute, in particular, to limit the optical outputpower of a laser diode. In such a context, we have carried out a set of complementary characterizations both at III-V lab and IMS allowing us to provide some corrective solutionsfor technological optimization concerning the etching depth of the grooves that defines the emitting stripe of the laser diode and the nature of the submount acting as a thermocompensator.These solutions have been proposed from optical modelling implemented with a dedicated simulator, property of III-V lab, and thermal and thermomechanical (multiphysics approach) finite element simulations of the overall microassembled structure. All this work has resulted in the fabrication as well as electro-optical and thermal characterizations of three vertical structures namely LOC (Large Optical Cavity), SLOC (Super Large Optical Cavity)and AOC (Asymmetrical Optical Cavity). The LOC and SLOC vertical structures have been processed with a Fabry-Perot cavity and also including a Bragg grating (DFB architecture) while the AOC one was only fabricated with a Fabry-Perot cavity. State-of-the-art results aredemonstrated since in particular an optical power of 8W with an efficiency of 60% has been obtained that can be compared to those recently published by the Ferdinand-Braun Institute.The originality of the work carried out in this PhD has allowed us to receive a grant from the European Laserlab Cluster (The Integrated Initiative of the European Laser Research Infrastructures), to conduct dedicated experiments at the Max-Born Institute (Berlin) in thegroup of Dr. J.W. Tomm. The work aimed to characterize mechanical strain of the laser diode induced by the soldering process. Two vertical structures (SLOC and AOC) were investigated using complementary techniques (microphotoluminescence, time-resolved photoluminescence,photocurrent spectroscopy and pulsed L-I measurements), allowing to quantify the level of residual stress provided by the laser diode mounting process as well as the kinetics of the catastrophic degradation process (COD).
112

Développement des sources lasers solides continues, visibles et stabilisées en fréquence : une alternative aux lasers à colorants / Development of solid state CW visible and frequency stabilized laser sources : an alternative to dye lasers

Mhibik, Oussama 05 December 2011 (has links)
Le traitement de l’information quantique, en particulier celui utilisant les centres colorés du diamant et la manipulation cohérente des ions de terre rare incorporés dans des matrices solides (Pr3+, Eu3+) et la spectroscopie à ultra-haute résolution, nécessitent des sources accordables ayant une faible largeur de raie. Or, dans la gamme rouge-orange (570-635 nm) où les diodes lasers font défaut et les lasers solides restent très peu développés, les lasers à colorants sont actuellement les seules sources de rayonnement cohérent disponibles. En revanche, ce type de laser est assez complexe et difficile à stabiliser au niveau du kHz à cause des bruits à haute fréquence générés par le jet de colorant.Pour répondre aux besoins des expériences citées ci-dessus, cette thèse vise à proposer une alternative “tout solide” aux lasers à colorants en explorant différentes possibilités pour la construction d’une source stable émettant dans l’orange-rouge. Dans ce but, nous avons proposé deux solutions:1. La première consiste à développer des oscillateurs paramétriques optiques. Dans cette voie, nous avons développé un OPO simplement résonant à doublage de fréquence intra-cavité et stabilisé en frequence au niveau du kHz.2. La deuxième consiste en un laser à base de fluorures dopés au Pr3+pompé par diode. / The quantum information processing using diamond color center or the coherent manipulation of rare earth ion embedded in solid state matrices (Pr3+, Eu3+) or the high resolution spectroscopy, require narrow linewidth tunable laser sources.However in the orange-red range (570-635 nm) where laser diodes are lacking and solid-state lasers are poorly developed, only dye lasers are currently available. Nevertheless these sources are complex and difficult to stabilize at the kHz level because of the high frequency noise induced by dye jet.The aim of this thesis is to give an all-solid state alternative of dye lasers. For this purpose, two solutions have been studied:1. The first approach consists on the development of an intracavity frequency doubled singly resonant optical parametric oscillator (OPO) and frequency stabilized at the kHz level.2. The second approach consists on the development of a diode pumped Pr-doped fluoride laser.
113

Spectrométrie laser de très haute compacité pour la mesure sous ballons de CH4, CO2 dans la troposphère et la stratosphère. / Highly compact laser spectrometry for balloon measurement of CH4, CO2 in the troposphere and stratosphere.

Miftah El Khair, Zineb 16 November 2018 (has links)
Au départ, j’ai développé un code d’inversion en se basant sur l’exemple donné au laboratoire. Ensuite, j’ai eu l’opportunité de l’appliquer en participant à la campagne de mesure in situ StratoScience 2015 au Canada. Durant cette campagne, on a aussi réalisé quelques comparaisons de l’Amulse avec d’autres instruments de mesure de CH4 et CO2 (PicoSDLA, Picarro, AirCore). Ce fut une expérience très enrichissante ainsi qu’un premier test pour l’Amulse. A partir des résultats de ce premier vol, on constate qu’il y a encore des améliorations à apporter, que ce soit au niveau instrumental qu’au niveau d’inversion. Sur le plan instrumental, on fait quelques interventions au niveau de l’intelligence de l’instrument (acquisition et stockage) et son optique, d’une part, d’autre part le code d’inversion a besoin de certaines modifications qui englobent la ligne de base et la détermination de la raie spectrale. Pour ce fait, j’essaye d’appliquer plusieurs méthodes pour obtenir un bon fit et par conséquent une bonne concentration. Concernant les travaux en cours, j’essaye toujours d’améliorer mon code d’inversion pour avoir un meilleur profil vertical, qui va être utilisé par la suite dans ma publication sur la mesure du méthane. Dans le cadre de la rédaction de la publication, j’ai fait une première calibration au laboratoire du senseur laser Amulse CH4 en attendant la deuxième. En outre, je développe un autre code d’inversion pour le projet Strateole 2 qui va durer 2 mois. J’interviens aussi au niveau de l’inversion des données de la calibration du nouveau senseur laser bi gaz APOGEE (CH4 et CO2), qui est prévue pour le mois de juin à Toulouse. Dernièrement, j’ai participé au congrès EGU à Vienne et dans un avenir proche, je vais participer à la campagne de Kiruna avec PicoSDLA, Amulse et APOGEE. / In the first place, I developed a code based on the example given in the laboratory. I had the opportunity to apply my program by participating in the in situ measurement campaign called StratoScience 2015, located in Canada. During this campaign, we also made some comparisons of Amulse with other CH4 and CO2 measurement instruments such as PicoSDLA, Picarro and AirCore. As matter of fact, it was a very rewarding experience and a first test for Amulse. From the results of this first flight, we decide to add some improvements on both sides: the instrumental and the process data part. Instrumentally, some changes has been required note only on the intelligence of the instrument including acquisition and storage but also on the optical part. Besides, the process data needs also some changes which include baseline and the determination of the spectral line. In fact, I try to apply several methods to get a good fit and therefore a good concentration. To this end, my current work is mainly focusing on improving my program for better vertical profile, because it will be used later in my publication on the measurement of methane. In the same context, I made a first calibration in the laboratory of Amulse CH4 laser sensor and preparing a second one. In addition, I developed another code for Stratéole 2 project which will last two months. I’ll also do the process data of the new dual laser sensor APOGEE (CH4 and CO2), which is scheduled for June in Toulouse. At last, I recently participate in the EGU congress in Vienna and in the near future, I will participate in a new campaign of in situ measurement in Kiruna with both sensors: PicoSDLA, and APOGEE Amulse.
114

\"Terapia endodôntica associada à irradiação do canal radicular com laser de diodo: avaliação térmica, morfológica, microbiológica e da infiltração marginal apical\" / Endodontic root canal therapy usindg diode laser irradiation: thermographic, morphological, microbiological and marginal apical leakge studies

Ribeiro, Adriana da Costa 06 February 2007 (has links)
O objetivo deste estudo foi avaliar os efeitos da irradiação do canal radicular pelo laser de diodo, quando associado à terapêutica endodôntica tradicional: no aumento da temperatura na superfície radicular externa; nas alterações morfológicas da dentina do canal radicular; no selamento marginal apical após obturação do canal radicular e no potencial de redução microbiana. O aumento de temperatura foi monitorado durante a irradiação do canal radicular de incisivos inferiores por câmera termográfica. Os parâmetros de irradiação foram: grupo de emissão contínua (CW): P=2,5 W e grupo de emissão pulsada ?P=1,25 W. A avaliação das alterações morfológicas por MEV das amostras irradiadas nas condições acima citadas foram comparadas com amostras não irradiadas. O grau de infiltração marginal apical foi mensurado em amostras irradiadas (CW; P = 2,5 W) ou não irradiadas, e obturadas por um dos três cimentos endodônticos: N-Rickert, AH Plus ou Apexit. O grau de penetração linear foi medido após o período de imersão das amostras na solução de azul de metileno. O potencial de redução microbiana promovido pela associação do laser à terapêutica endodôntica tradicional foi avaliado em dentes portadores de infecção endodôntica primária por técnicas de cultura e PCR. A irrigação de NaOCl 0,5 % e uso de hidróxido de cálcio (grupo controle) foram associados à irradiação no grupo laser (CW; P=2,5 W). Foram avaliadas: a redução do número de UFC dos anaeróbios viáveis, a quantidade de E. faecalis e de lactobacilos/amostra, e a proporção de E. faecalis e de lactobacilos/microrganismos viáveis. O aumento de temperatura na superfície radicular externa durante a irradiação do canal radicular nos regimes de emissão contínuo e pulsado não excedeu o limite crítico de 10 ºC. A variação de 10 temperatura mediana máxima na região apical usando o método de Wilcoxon (p < 0,05) foi de 8,6 °C na irradiação contínua e de 3,3 °C na emissão pulsada. O tempo de resfriamento de 20 segundos foi determinado entre os 5 ciclos de irradiação. As alterações morfológicas promovidas pela irradiação do canal revelaram fusão da dentina e obliteração dos túbulos dentinários especialmente no terço apical, em ambas as condições de irradiação. A irradiação do canal radicular pelo laser de diodo reduziu significativamente o grau de infiltração marginal apical nos canais obturados pelo cimento Apexit (Kruskal Wallis p < 0,05). A prevalência dos anaeróbios viáveis ao final do tratamento foi menor no grupo laser do que no grupo controle, embora não tivesse sido constatada diferença significante entre os grupos (Mann-Whitney p > 0,05). O porcentual de lactobacilos/microrganismos viáveis no início do tratamento foi 22 % reduzindo a zero ao final, no grupo controle. Esse microrganismo não foi detectado no grupo laser. A proporção de Enterococcus/microrganismos viáveis variou de 36 %-50 % no grupo controle, e 22 %-0 % no grupo laser, no início e final do tratamento, respectivamente. Nas condições testadas, os resultados sugerem que o laser de diodo mostrouse uma ferramenta possível de ser incorporada à Endodontia, contudo os efeitos biológicos são similares à terapêutica endodôntica tradicional bem executada. / The aim of this study was to evaluate the effects of diode laser irradiation associated with endodontic therapy. The aspects analyzed were: temperature rise at the external root surface, morphological changes at the dentine root walls, apical marginal leakage after root sealing, and microbiological reduction after laser irradiation. The temperature rise in inferior incisor teeth was monitored using a thermographic camera. Two laser treatment parameters were investigated: continuous emission mode (CW) with P = 2.5 W and pulsed emission mode (PL) with average power?P = 1.25 W. The morphological changes of irradiated samples were analyzed by SEM for both treatment modes and compared with a non-irradiated control group. The apical marginal leakage was measured after the immersion in methylene blue solution for irradiated (CW; P = 2.5 W) and non-irradiated samples sealed by one of the following endodontic sealers: N-Rickert, AH Plus or Apexit. The reduction in microbiological activity after conventional endodontic therapy and after laser irradiation was evaluated in primary endodontic infection using culture and PCR techniques, where the control group used conventional 0.5 % NaOCl solution and calcium hydroxide treatment was compared with laser irradiation (CW; P = 2.5 W). The reduction of viable anaerobic microorganisms, the quantity of E. faecalis and Lactobacillus per samples, and the rate of E. faecalis and Lactobacillus per viable microorganism were analyzed. The temperature rise at external root surface during root canal irradiation in both continuous and pulsed emission modes was demonstrated not exceed the safety limit of 10 ºC. The maximum median temperature variation was 8.6 °C (CW) at the continuous emission mode and 1.6 °C at pulsed mode (PL) (Wilcoxon, p < 0.05). The optimal ?resting time? between each of five irradiation cycles was 12 determined to be 20 seconds to allow for tissue cooling and hence to prevent potential dangerous rises in the tissue temperature. SEM analysis revealed melting of dentine and closure of dentinal tubules especially at apical third for both irradiation conditions. The apical marginal leakage was significant reduced in the irradiated samples sealed with Apexit (Kruskal Wallis, p < 0.05). The prevalence of the viable anaerobic microorganisms exhibited reduced with time in both the control and laser groups with no statistical difference (Mann-Whitney p > 0.05). The Lactobacillus rate per viable microorganisms in the control group was 22 % at the beginning of the treatment and decreasing to zero at the end. This microorganism was not detected in laser group. The rate of Enterococcus per viable microorganism ranged 36 % to 50 % in the control group and 22 % to 0 % in laser group at the begin and the end of treatments, respectively. The conclusion is that diode laser technology is suitable for applications in endodontic therapy under the conditions tested in this study, however, the biological effects are similar to well done conventional endodontic therapy.
115

Towards an electrically-injected optical parametric oscillator / Vers un oscillateur paramétrique optique injecté électriquement

Bernard, Alice 10 July 2018 (has links)
Le travail présenté dans cette thèse porte sur la conception, la fabrication et la caractérisation de sources prévues pour fonctionner à la fois comme diode laser et comme oscillateur paramétrique optique. Ces lasers sont conçus pour émettre sur un mode d’ordre supérieur afin de permettre une conversion de fréquence paramétrique avec les modes fondamentaux du guide à la fréquence moitié. La diode laser et l’OPO partagent la même cavité optique ; pour assurer l’accord de phase et corriger les écarts à la structure nominale induits lors de l’élaboration par épitaxie, la largeur de ruban est utilisée comme paramètre de contrôle des indices efficaces. Les diodes proposées sont donc étroites (3-5 µm) et gravées profondément. En conséquence, il est potentiellement intéressant d’utiliser des boîtes quantiques pour limiter les recombinaisons non radiatives sur les flancs. Dans le cadre de ce travail, nous avons conçu des diodes basées sur ce principe pour les deux systèmes GaAs/AlGaAs et InGaAsP/InP, qui permettent respectivement d’obtenir potentiellement une émission OPO au voisinage de 2 µm ou de 3 µm. Dans le cas de l’InGaAsP/InP, nous avons étudié au préalable l’indice de réfraction des alliages InGaAsP dans une plage de longueur d’onde jusque-là non couverte par la littérature. Ces données ont été acquises via des mesures d’indice efficace (m-lines) de couches guidantes d’InGaAsP épitaxiées en accord de maille sur un substrat d’InP. Pour des structures laser-OPO optimisées, les simulations montrent que le seuil OPO devrait être obtenu pour une puissance de pompe intracavité de quelques centaines de mW, qu’il est réaliste d’atteindre pour des diodes laser à l’état de l’art. Nous avons étudié les propriétés électro-optiques de diodes lasers à puits quantiques GaAs/AlGaAs réalisées sur la base de nos dessins; l’observation de l’effet laser sur le mode TE2 valide le dessin vertical original de nos diodes lasers. En vue de la fabrication de laser-OPO à ruban étroit, nous avons développé des procédés de fabrication nouveaux sur la Plateforme Technologique Amont (CEA – Grenoble), notamment la gravure profonde (>10 µm) par ICP-RIE. Enfin, nous avons proposé un concept alternatif de diode-OPO, comprenant des cavités laser et OPO distinctes couplées par un taper adiabatique / The work presented in this thesis deals with the design, fabrication and characterization of sources intended to function as both laser diodes and optical parametric oscillators. These lasers are designed to emit on a higher order mode to allow parametric frequency conversion with fundamental modes of the guide at half frequency. The laser diode and OPO share the same optical cavity; to ensure phase matching and correct nominal structure deviations induced during epitaxial processing, the ridge width is used as a control parameter of the effective indices. The proposed diodes are therefore narrow (3-5 μm) and etched deeply. Consequently, it is potentially interesting to use quantum dots to limit non-radiative recombination on the sidewalls. In the context of this work, we have designed diodes based on this principle for the two GaAs/AlGaAs and InGaAsP/InP systems, which respectively allow to potentially obtain an OPO emission in the vicinity of 2 μm or 3 μm. In the case of InGaAsP/InP, we previously studied the refractive index of InGaAsP alloys in a wavelength range not covered by literature to this day. This data was acquired via effective m-line index measurements of InGaAsP guiding layers epitaxially grown on and lattice-matched to an InP substrate. For optimized laser-OPO structures, simulations show that the OPO threshold should be obtained for an intracavity pump power of a few hundred mW, which is realistic to achieve for state-of-the-art laser diodes. We have studied the electro-optical properties of GaAs/AlGaAs quantum well laser diodes made on the basis of our designs; the observation of the laser effect on the TE2 mode validates the original vertical design of our laser diodes. For the manufacture of narrow-ridge lasers-OPOs, we have developed new manufacturing processes on the Plateforme Technologique Amont (Upstream Technology Platform, CEA - Grenoble), including deep etching (> 10 μm) by ICP-RIE. Finally, we have proposed an alternative diode-OPO concept, comprising distinct laser and OPO cavities coupled by an adiabatic taper
116

Instruments de Mesure Multi-Polluants par Spectroscopie Infrarouge basés sur des Lasers Fibrés et par Génération de Différence de Fréquences : Développement et Applications

Cousin, Julien 12 December 2006 (has links) (PDF)
Aujourd'hui la détection des COV et autres polluants anthropiques à l'état de trace est un enjeu de plus en plus important pour la surveillance de la qualité de l'air. La spectroscopie infrarouge, permettant de sonder des régions spectrales riches en absorption moléculaire, est une technique appropriée pour une mesure in-situ de la pollution atmosphérique. Ce travail de thèse a ainsi consisté à développer des instruments lasers de mesure multi-polluants de terrain. Un premier projet a consisté à profiter de la disponibilité des lasers des télécommunications émettant dans l'IR proche. Cet instrument a été réalisé sur la base d'une diode laser à cavité étendue (1500 - 1640 nm), couplée à une cellule à réflexions multiples (100 m). La sensibilité de détection a été optimisée en employant une détection balancée et une procédure de moyenne de spectres. La compacité et la sensibilité (< 10-7 cm-1Hz-1/2) obtenues ont permis la quantification de composés, en laboratoire ou in-situ, tels que CO2, CO, C2H2, CH4 et également la détermination du rapport isotopique 13CO2/12CO2 résultant de la combustion de bois. Le deuxième projet a consisté à mélanger deux lasers du proche IR (lasers à fibre dopée) dans un cristal non linéaire (PPLN) afin de produire un rayonnement laser par génération de différence de fréquences dans l'IR moyen (3,15 - 3,43 µm), là où les bandes d'absorption des molécules visées, sont les plus intenses. Les premières études avec cette source montrent la possibilité de détection de l'éthylène (C2H4) et du benzène (C6H6). Les développements, caractérisations et applications de ces instruments, aussi bien dans l'IR proche que moyen, sont détaillés et montrent les avantages de sonder les 2 gammes spectrales.
117

Vergleich der Dekontaminationswirkung von Dioden- und Er:YAG-Laserlicht sowie chemischen Desinfektionslösungen auf Titanoberflächen mit oralen Biofilmen-Eine in-vitro-Studie ex vivo / Comparison of decontamination efficacy of diode laser, Er:YAG laser and chemical antimicrobial agents on titanium surfaces with oral biofilms-A study in-vitro ex vivo

Eiffert, Johanna Katharina 23 January 2012 (has links)
No description available.
118

Nouveaux concepts pour des sources laser bleues à base de cristaux dopés Néodyme

Hérault, Emilie 12 February 2007 (has links) (PDF)
Les sources laser bleues possèdent des applications nombreuses et varies (shows laser, affichage, médecine, spectroscopie, communications sous-marines, stockage de données). Lors de cette thèse, nous avons démontré qu'avec de nouveaux concepts, il est possible de réaliser des sources bleues originales à base de cristaux dopés néodyme. Nous avons dans un premier temps proposé une alternative au laser à Argon en concevant une source basée sur la somme de fréquence de deux raies du néodyme émettant autour de 1060 nm et 910 nm. Afin de choisir le cristal optimal, nous avons mené une étude comparative sur certaines caractéristiques physiques et les performances laser sur la transition 4F3/2-4I9/2 des cristaux de Nd:GdVO4 et Nd:YVO4. Nous avons ensuite conçu et réalisé quatre architectures laser émettant en continu à 491 nm, toutes à base de somme de fréquence intracavité. Les deux premières étaient basées sur des laser bi-longueur d'onde à un seul ou deux cristaux laser. La troisième était composée de deux lasers dont les cavités étaient imbriquées, le cristal non linéaire étant inséré dans la partie commune. Finalement, nous avons réalisé un laser émettant à 1064 nm pompé intracavité à 912 nm. Sur le même principe, nous avons conçu une source en régime déclenché à 491 nm grâce à un nouveau concept d'extraction de puissance par interaction non linéaire. La somme de fréquence a alors lieu intracavité à 912 nm mais extracavité à 1063 nm. Finalement, nous avons étudié et réalisé un laser fonctionnant sur la transition à trois niveaux de l'ion néodyme. Par génération de second harmonique, nous avons ainsi réalisé des sources bleues de longueur d'onde inférieure à 450 nm.
119

STABILISATION D'UNE DIODE LASER ACCORDABLE PAR FILTRAGE AUTO-ORGANISABLE

Godard, Antoine 10 June 2003 (has links) (PDF)
Les diodes laser à cavité étendue commerciales offrent une émission monomode continû-ment accordable autour de 1550 nm sur une plage allant jusqu'à 150 nm. De telles performances nécessitent une excellente stabilité mécanique et des ajustements très délicats. De plus, pour éviter tout fonctionnement multimode, la puissance maximale doit être limitée. L'insertion d'un cristal photoréfractif dans le résonateur crée un filtre spectral adaptatif qui permet de relâcher ces contrain-tes. Dans ce manuscrit, nous démontrons et modélisons le fonctionnement d'un tel système.<br />Tout d'abord, nous étudions les conditions requises pour garantir une oscillation monomode stable en absence de cristal. Les processus non-linéaires induisant des mélanges d'ondes (hole bur-ning spectral, échauffement des porteurs et pulsations de la densité de porteurs) et donc des coupla-ges entre modes sont étudiés et pris en compte pour modéliser les conditions de sauts de modes.<br /> Ensuite, nous modélisons le filtre photoréfractif. Son principe de fonctionnement est le sui-vant : la figure d'onde stationnaire du mode est reproduite dans le volume du cristal sous la forme d'une modulation d'indice qui correspond donc à un réseau de Bragg et agit comme un filtre spec-tral. Une stabilisation du mode oscillant est obtenue grâce à l'effet combiné de ce filtre adaptatif et du filtrage passif de la cavité étendue (réseau monté en configuration Littman).<br /> Puis, nous présentons les améliorations apportées par cette technique de filtrage auto-organisable. Expérimentalement, nous démontrons que, grâce une prévention efficace des sauts de modes et des fonctionnements multimodes, une oscillation monomode stable peut être maintenue pour des puissances supérieures à celles atteignables en absence de cristal. Enfin, nous confrontons les mesures aux modélisations de la cavité auto-organisable où les phénomènes de couplage de mo-des et le filtre photoréfractif sont pris en compte simultanément.
120

Etude théorique et expérimentale de diodes lasers, pour horloges Rubidium et Césium, refroidissement d'atomes et capteurs inertiels

Cayron, Charles 01 December 2011 (has links) (PDF)
Dans le cadre de l'interaction lumière-atomes, les diodes lasers nécessitent des performances optiques spécifiques : de fortes puissances optiques à une longueur d'onde spécifique (852 nm ou 894 nm pour les atomes de Césium, 780 nm ou 795 nm pour le Rubidium), un fonctionnement monomode transverse et longitudinale du faisceau. Ce mémoire de thèse présente les différentes étapes permettant la fabrication de diodes lasers, émettant à 780 nm, répondant à ces caractéristiques optiques. La spécificité des diodes lasers développé lors de cette thèse est l'absence d'aluminium dans la zone active des lasers, offrant de meilleures performances en termes de fiabilité. Il décrit dans un premier temps les principes du pompage atomique et du refroidissement d'atome afin de déterminer un cahier des charges spécifiques pour les diodes lasers à développer. Il expose ensuite les concepts théoriques permettant de comprendre le fonctionnement d'une diode laser. La caractérisation des diodes lasers développées lors de cette thèse a pu démontrer un fonctionnement monomode transverse jusqu'à des puissances optiques supérieurs à 100 mW pour des lasers Fabry-Pérot. La réalisation de diodes lasers DFB (ayant un réseau de Bragg intégré dans la cavité optique du laser) a montré un fonctionnement monomode fréquentiel jusqu'à 25 mW avec des taux de réjection des modes satellites supérieurs à 45 dB et une largeur de raie de 550 kHz. Enfin, une première étude théorique et expérimentale à partir de diodes lasers émettant à 852 nm a été réalisé afin d'estimer les performances de ces composants dans des horloges à jet thermique utilisant des atomes de Césium.

Page generated in 0.0539 seconds