• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 1
  • Tagged with
  • 11
  • 11
  • 9
  • 9
  • 6
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportamento das dobras cutaneas no processo de maturação sexual

Duarte, Maria de Fatima da Silva January 1986 (has links)
Dissertação (mestrado) - Universidade de São Paulo, Escola de Educação Fisica / Made available in DSpace on 2012-10-16T00:11:45Z (GMT). No. of bitstreams: 0
2

Desenvolvimento e validação de modelos de medição da densidade corporal de um grupo de universitários / DEVELOPING AND VALIDATING THE MODELLING OF CORPOREAL DENSITY MEASURING IN A GROUP OF UNDERGRADUATE STUDENTS

Cursino, Carlos Magno Padilha 02 October 2009 (has links)
Made available in DSpace on 2015-05-08T14:59:52Z (GMT). No. of bitstreams: 1 parte1.pdf: 1996084 bytes, checksum: 09744470d202aa00bc1822961cfea571 (MD5) Previous issue date: 2009-10-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Estimating corporeal density and fat in human bodies can be realized by using several laboratory methods: directly, indirectly or double indirect. The direct method is the only one which allows estimating the corporeal fat with such a better precision by means of dissecting the cadaver. In order to get this estimative, one of the most precise indirect method is the one of hydrostatic weight, which is considered the reference one in this study. For estimating the corporeal fat the double indirect method has been used by predicting measure models, which have been developed for populations of different ethnic groups. Many times these models have been employed with no criterion, occasioning errors. In this thesis the corporeal density measuring and fat percentage of 199 undergraduate students were estimated, with 62 female students in the age between 18 and 27 and 137 male students in the age between 18 and 35. Measuring skinfold thickness, height and body mass have been done in the group of undergraduate students. Models for estimating the body density were developed and validated. Thirteen of the models were made for the females and eleven of them were developed for the males. It has been conducted a cross validation of the eleven male measuring models which have been developed in this thesis, as well as of six measuring models which have been developed by other authors. A comparison has been made between the body densities measured by using the standard method and the densities which were estimated by the models.Three models used for the females attended the Heyward & Stolarczyk criterion, as well as the morphology one and the practical one. Through validation they presented a correlation coefficient (R) between 0.802 and 0.835, and an estimating standard error (EPE) between 0.0070 g/cm3 and 0.0075 g/cm3. Four measuring models which have been developed in this study for the male sex, within the cross validation procedure, presented strong correlations between 0.774 and 0.805, and EPE between 0.0065 g/cm3 and 0.0070 g/cm3. These values were classified by Lohman as very good. They attended the Heyward & Stolarczyk criteria, the morphology one and the practical one. No one of the six measuring models which have been developed by other authors was recommended for being used in this sample once they did not attend the validation criteria. / A estimativa da densidade e da gordura corporais pode ser realizada por vários métodos laboratoriais, de forma direta, indireta ou duplamente indireta. O método direto é o único que pode estimar a gordura corporal com maior exatidão, utilizando a dissecação cadavérica. Para essa estimativa, um dos métodos indiretos mais precisos é o da pesagem hidrostática, considerado como padrão nesse estudo. Utiliza-se o método duplamente indireto para essa estimativa, por meio de modelos de medição preditivos, desenvolvidos para populações de etnias diferentes, e empregados, muitas vezes sem os devidos critérios, gerando erros. Neste trabalho, estimaram-se as medidas de densidade corporal e do percentual de gordura de 199 universitários, dos quais 62 são do sexo feminino com idade entre 18 e 27 anos e 137 do sexo masculino com idade entre 18 e 35 anos. Realizaram-se medidas de dobras cutâneas, estatura e massa corporal dos universitários. Foram desenvolvidos e validados modelos de medição da densidade corporal, sendo treze para o sexo feminino e onze para o sexo masculino. Realizou-se a validação cruzada dos onze modelos de medição do sexo masculino desenvolvidos nesse estudo bem como de seis modelos de medição desenvolvidos por outros autores, comparando as densidades medidas pelo método padrão com as densidades estimadas pelos modelos. Três modelos, para o sexo feminino, atenderam ao critério de Heyward & Stolarczyk, bem como, ao de morfologia e ao de praticidade e apresentaram, na validação, coeficiente de correlação (R) entre 0,802 e 0,835 e erro padrão de estimativa (EPE) entre 0,0070 g/cm3 e 0,0075 g/cm3. Quatro modelos de medição, desenvolvidos nesse estudo para o sexo masculino, no procedimento de validação cruzada, apresentaram fortes correlações entre 0,774 e 0,805 e EPE entre 0,0065 g/cm3 e 0,0070 g/cm3, classificados segundo Lohman, como muito bom, atenderam aos critérios de Heyward & Stolarczyk, ao de morfologia e ao de praticidade. Nenhum dos seis modelos de medição desenvolvidos por outros autores foram recomendados para serem utilizados nessa amostra, pois não atenderam aos critérios de validação.
3

Avaliação da Gordura Corporal Como Fator de Risco Cardio Vascular em Funcionários de uma Universidade Pública da Cidade do Recife/PE

PONZI, Fabíola Karine Arruda Xavier 31 January 2012 (has links)
Submitted by Nayara Passos (nayara.passos@ufpe.br) on 2015-03-04T13:00:50Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) 2012-Dissertação-Fabíola-Ponzi.pdf: 1617057 bytes, checksum: 465ed434846eda8e4d2c314a561964f3 (MD5) / Made available in DSpace on 2015-03-04T13:00:50Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) 2012-Dissertação-Fabíola-Ponzi.pdf: 1617057 bytes, checksum: 465ed434846eda8e4d2c314a561964f3 (MD5) Previous issue date: 2012 / CNPQ
4

Análise da qualidade de vida de pacientes submetidos a abdominoplastia circunferencial após tratamento cirúrgico da obesidade mórbida / Quality of life analysis in patients submitted to circumferential abdominoplasty after surgical treatment of the morbid obesity

Cintra Júnior, Wilson 05 June 2006 (has links)
INTRODUÇÃO: Os pacientes portadores de obesidade mórbida submetidos a tratamento cirúrgico para obesidade através de cirurgias desabsortivas-restritivas, após considerável perda de peso, podem apresentar excessos dermogordurosos nas várias regiões do corpo, freqüentemente associados à dificuldade de higiene pessoal e deambulação, maior incidência de infecções cutâneas, insatisfação com a imagem corporal, piora na auto-estima e nos relacionamentos profissionais e afetivos, além da piora da qualidade de vida. Naqueles pacientes com excessos dermogordurosos em abdome e flancos, e ptose da região glútea, a abdominoplastia circunferencial tem demonstrado ser uma solução cirúrgica eficaz. OBJETIVO: Avaliar as alterações na qualidade de vida dos pacientes submetidos a abdominoplastia circunferencial, nos aspectos afetivo-relacional, profissional, social e orgânico. MÉTODOS: Dezesseis pacientes do sexo feminino, que realizaram abdominoplastia circunferencial entre agosto de 2000 e janeiro de 2005, e eram acompanhadas no ambulatório de Cirurgia Plástica da Divisão de Cirurgia Plástica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, foram submetidas à entrevistas psicológicas semidirigidas, que consistiram de 31 questões, cujas respostas obtidas foram tabuladas e divididas em categorias. Utilizando-se a Escala Diagnóstica Adaptativa Operacionalizada (EDAO), e tendo como princípio norteador o critério adaptativo, as respostas foram classificadas como adequadas, pouco adequadas ou pouquíssimo adequadas. Através de notas atribuídas a cada resposta, foi possível a avaliação quantitativa nos quatro setores de funcionamento (afetivo-relacional, produtividade, sócio-cultural e orgânico) e a classificação diagnóstica das pacientes quanto à adequação. RESULTADOS: No setor afetivo-relacional, dez pacientes (62,5%) apresentaram respostas adequadas e cinco (31,25%), pouco adequadas. No setor produtividade, dez pacientes (62,5%) apresentaram respostas adequadas e quatro (25%), pouco adequadas. No setor sócio-cultural, treze pacientes (81,25%) apresentaram respostas adequadas. No setor orgânico, dez pacientes (62,5%) apresentaram valores máximos em todos os indicadores avaliados. Sete pacientes (43,75%) apresentaram adaptação eficaz e seis (37,5%), ineficaz leve. CONCLUSÕES: As análises, qualitativas e quantitativas, realizadas através da EDAO, concluiram que houve benefício efetivo aos pacientes submetidos a abdominoplastia circunferencial, nos aspectos físico, profissional, social e orgânico. / INTRODUCTION: Morbid obesity patients submitted to surgical treatment through disabsorptive/restrictive procedures, after considerable weight loss, may present skin and fat excess throughout different body regions, frequently associated with restrictions on personal hygiene and deambulation, greater incidence of skin infections, body image dissatisfaction, worsening of self-steem and of professional and affective relationships, besides down grading quality of life in general. On those patients that present skin and fat excess on the abdomen, flanks and gluteal ptosis, the circumferential abdominoplasty has demonstrated to be an effective surgical solution. OBJECTIVE: To evaluate the modifications on the quality of life of patients that underwent circumferential abdominoplasty on affective/relational, professional, social and organic aspects. METHODS: Sixteen female patients that underwent circumferential abdominoplasty between August 2000 and January 2005 were followed on the outpatient clinic of the Plastic Surgery Division of the Hospital das Clínicas of the University of São Paulo, and were submitted to semi-directed psychological interviews that consisted in 31 questions whose answers were tabulated and separated in categories. One used the Operational Adaptive Diagnostic Scale (OADS) and observing the adaptive patterns as the main criterion, the answers were classified as fairly, poorly and least poorly adequate. Through grades attributed to each answer, it was possible to evaluate quantitatively the four aspects of observation (affective/relational, professional, social and organic) and to establish a classification of the patients relative to their adaptive adequacy. RESULTS: On the aspect affective/relational, ten patients (62.5%) presented fairly adequate answers and five (31.25%) poorly adequate ones. On the productivity aspect, 10 patients (62.5%) presented fairly adequate answers and four (25%) poorly adequate ones. On the social/cultural aspect, 13 patients (81.25%) presented fairly adequate answers. On the organic aspect, 10 patients (62.5%) presented maximum grades in all evaluated criteria. Seven patients (43.75%) presented effective adaptation and six (37.5%) slightly ineffective. CONCLUSIONS: The qualitatively and quantitatively analysis made through OADS showed that there was effective benefit to the patients submitted to circumferential abdominoplasty on the physical, professional, social and organic aspects.
5

Avaliação da confiabilidade e concordância de métodos de avaliação da composição corporal em mulheres no período reprodutivo / Evaluation of reliability and consistency of body composition assessment methods in women in reproductive period

Silva, Rafael Costa 12 January 2016 (has links)
Objetivos: Avaliar a composição corporal através da medida das dobras cutâneas (DC) intra e inter observador em mulheres na fase reprodutiva. Estimar a confiabilidade de dois protocolos de medidas de dobras cutâneas com o método Absorciometria Radiológica de Dupla Energia (DEXA). Métodos: A amostra foi composta por 90 mulheres com faixa etária de 18 a 37 anos, com Índice de Massa Corporal entre 18 e <= 39,9 Kg/m². A reprodutibilidade dos métodos foram avaliados pelos coeficientes de correlação de concordância (CCC) e coeficiente de Saint Laurent e pelos limites de concordância e gráficos de Bland-Altman. Resultados: A comparação intra observador foi excelente (CCC = 0,99) para os valores das medidas de DC tricipital, supraíliaca, coxa, soma das dobras e percentual de gordura. O mesmo ocorreu na comparação inter observador (CCC = 0,99). As medidas das DC tricipital foram as que apresentaram maior CCC (0,98), seguido da medida da coxa (0,90), e a medida da DC da suprailíaca foi a menor (0,89). A soma das DC e o percentual de gordura tiveram valores de 0,95. Já os protocolos de medidas de DC comparados entre si e com o padrão ouro DEXA, obtiveram valores de concordância baixa (0,35). Conclusões: Nossos achados mostraram que a comparação intra e inter observador foi satisfatória, contribuindo para a reprodutibilidade das medidas de DC. Os protocolos de avaliação das DC não tiveram concordância quando comparados com a DEXA / Objectives: Assessing body composition by measuring the intra and inter observer skin folds in women in the reproductive phase and estimate the reliability of two protocols skinfold measures with radiographic absorptiometry method of dual energy absorptiometry (DEXA). Methods: The sample consisted of 170 women aged 18-37 years with body mass index between 18 and <= 39.9 kg / m². The reproducibility of methods and skinfold thickness were evaluated by the coefficient of concordance correlation (CCC) and coefficient of Saint Laurent and the limits of agreement and Bland-Altman. Results: Comparison intra observer was excellent with the same values of the CCC (0.99) for the measurements of skinfold thickness of the triceps, suprailiac, thigh and fat percentage. The same occurred in the comparison inter observer (CCC = 0.99). The measures of skinfold thickness of the triceps showed the greatest CCC (0.98), followed by thigh (0.90), and the suprailiac was the lowest (0.89). The sum of the measurements of skinfold thickness and the percentage of fat had CCC values of 0.95. Already the reliability of two protocols skinfold thickness measures compared with the gold standard DEXA method was low (CCC = 0.35). Conclusions: Our findings showed that compared intra and inter observer was satisfactory, contributing to the reproducibility of skin folds. Assessment protocols skinfold did not have agreement when compared with DEXA
6

Relação entre antropometria, composição corporal, peso ao nascer, taxa metabólica de repouso e dispêndio energético diário de crianças dos 7 aos 10 anos de idade da cidade de Vitória de Santo Antão

NOBRE, Isabele Góes 23 February 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-08-31T15:21:18Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertaçao Isabele Góes Nobre (1).pdf: 1399652 bytes, checksum: 5fc0dc11dec680183355feff43c22a5f (MD5) / Made available in DSpace on 2016-08-31T15:21:18Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertaçao Isabele Góes Nobre (1).pdf: 1399652 bytes, checksum: 5fc0dc11dec680183355feff43c22a5f (MD5) Previous issue date: 2016-02-23 / Os objetivos do presente estudo foram: a) analisar estudos que consideram os efeitos do baixo peso ao nascer (BPN) em crianças e sua relação com a antropometria e composição corporal durante o crescimento; b) descrever variáveis antropométricas e de composição corporal e metabolismo energético de acordo com o peso ao nascer; c) verificar a associação entre peso ao nascer, taxa metabólica de repouso (RMR) e gasto energético diário (DEE) com variáveis antropométricas e de composição corporal; d) estabelecer um modelo preditivo para RMR e DEE considerando a influência da antropometria, composição corporal e peso ao nascer em crianças de 7 a 10 anos de idade. Foram avaliadas 464 crianças (241 meninos e 223 meninas) nascidos em Vitória de Santo Antão (Nordeste do Brasil). Variáveis utilizadas: Antropometria (peso, altura, altura do assento, cintura, quadril, braço, perna e perímetro cefálico), composição corporal (dobras cutâneas, área muscular do braço e percentual de gordura corporal [% BF]), RMR e DEE. A noção de que o BPN pode promover um rearranjo no metabolismo energético é plausível. Há uma associação positiva entre o BPN e a redução do peso corporal, estatura, massa livre de gordura e um aumento da massa de gordura. Crianças de 8-10 anos com BPN apresentaram valores médios elevados para a maioria das variáveis quando comparado com crianças de 7 anos de idade, enquanto que para as com BPN, as diferenças estavam entre todas as idades analisadas. O peso ao nascer foi positivamente correlacionado com a circunferência da cabeça (8-10 anos), RMR, DEE, altura e %BF (9-10 anos). Todas as variáveis antropométricos e de composição corporal foram fortemente correlacionadas com RMR e DEE. A partir do modelo de regressão, a altura, circunferência do quadril, % BF, dobras cutâneas tricipital e subescapular foram preditores significativos para RMR e DEE, independentemente da idade. Preditores relevantes da RMR e DEE foram dobra cutânea bicipital aos 8 anos, circunferência da perna aos 9-10 anos, e prega cutânea supra-ilíaca em ambas as idades. O principal determinante da RMR e DEE foi % BF. Crianças com BPN apresentaram um déficit no ganho de medidas antropométricas e de composição corporal em todas as idades. Para o metabolismo energético, a variação na estrutura do corpo das crianças pode ser relacionada com a reestruturação do componente de gordura, uma vez que as diferenças observadas entre as idades estão ligados aos seus indicadores. / The goals of the present study were: a) To analyze studies that consider the effects of low birth weight children and the relationship with anthropometry and body composition during growth; b) To describe anthropometric and body composition variables and energy metabolism according to birth weight; c) to verify the association between birth weight, resting metabolic rate (RMR) and daily energy expenditure (DEE) with anthropometry and body composition variables; d) To stablish a predictive model for RMR and daily energy expenditure (DEE) considering the influence of anthropometry, body composition and birth weight in children at 7 to 10 years old. It was evaluated 464 children (241 boys and 223 girls) born in Vitoria de Santo Antão (Northeast of Brazil). Anthropometry (weight, height, sitting height, waist, hip, arm, leg and head circumferences), body composition (skinfold thickness, arm muscle area and body fat percentage [%BF]), RMR and DEE were evaluated. The notion that the low birth weight can promote an rearrangement in energy metabolism is plausible. There is a positive association between LBW and reduced body weight, body height, fat-free mass and an increase in fat mass. LBW children from 8 to 10y old showed high mean values for the most variables when compared to 7 y old, while for NBW children, the differences were among all ages analyzed. The birth weight was positively correlated with head circumference (8-10y old), RMR, DEE, sitting height and %BF (9-10y old). All anthropometric and body composition variables were strongly positively correlated with RMR and DEE. From the regression model, height, hip circumference, %BF, tricipital and subscapular skinfolds were significant predictors for RMR and DEE regardless age. Relevant predictors of RMR and DEE were bicipital skinfold at age 8y, leg circumference at 9-10y, and suprailiac skinfold in both ages. The major determinant of RMR and DEE was %BF. LBW children showed a deficit in gain of anthropometric and body composition measurements throughout age. For the energy metabolism, variation in body structure of children can be related to restructuring of the fat component, since the differences observed between ages are attached to their predictors.
7

Avaliação da confiabilidade e concordância de métodos de avaliação da composição corporal em mulheres no período reprodutivo / Evaluation of reliability and consistency of body composition assessment methods in women in reproductive period

Rafael Costa Silva 12 January 2016 (has links)
Objetivos: Avaliar a composição corporal através da medida das dobras cutâneas (DC) intra e inter observador em mulheres na fase reprodutiva. Estimar a confiabilidade de dois protocolos de medidas de dobras cutâneas com o método Absorciometria Radiológica de Dupla Energia (DEXA). Métodos: A amostra foi composta por 90 mulheres com faixa etária de 18 a 37 anos, com Índice de Massa Corporal entre 18 e <= 39,9 Kg/m². A reprodutibilidade dos métodos foram avaliados pelos coeficientes de correlação de concordância (CCC) e coeficiente de Saint Laurent e pelos limites de concordância e gráficos de Bland-Altman. Resultados: A comparação intra observador foi excelente (CCC = 0,99) para os valores das medidas de DC tricipital, supraíliaca, coxa, soma das dobras e percentual de gordura. O mesmo ocorreu na comparação inter observador (CCC = 0,99). As medidas das DC tricipital foram as que apresentaram maior CCC (0,98), seguido da medida da coxa (0,90), e a medida da DC da suprailíaca foi a menor (0,89). A soma das DC e o percentual de gordura tiveram valores de 0,95. Já os protocolos de medidas de DC comparados entre si e com o padrão ouro DEXA, obtiveram valores de concordância baixa (0,35). Conclusões: Nossos achados mostraram que a comparação intra e inter observador foi satisfatória, contribuindo para a reprodutibilidade das medidas de DC. Os protocolos de avaliação das DC não tiveram concordância quando comparados com a DEXA / Objectives: Assessing body composition by measuring the intra and inter observer skin folds in women in the reproductive phase and estimate the reliability of two protocols skinfold measures with radiographic absorptiometry method of dual energy absorptiometry (DEXA). Methods: The sample consisted of 170 women aged 18-37 years with body mass index between 18 and <= 39.9 kg / m². The reproducibility of methods and skinfold thickness were evaluated by the coefficient of concordance correlation (CCC) and coefficient of Saint Laurent and the limits of agreement and Bland-Altman. Results: Comparison intra observer was excellent with the same values of the CCC (0.99) for the measurements of skinfold thickness of the triceps, suprailiac, thigh and fat percentage. The same occurred in the comparison inter observer (CCC = 0.99). The measures of skinfold thickness of the triceps showed the greatest CCC (0.98), followed by thigh (0.90), and the suprailiac was the lowest (0.89). The sum of the measurements of skinfold thickness and the percentage of fat had CCC values of 0.95. Already the reliability of two protocols skinfold thickness measures compared with the gold standard DEXA method was low (CCC = 0.35). Conclusions: Our findings showed that compared intra and inter observer was satisfactory, contributing to the reproducibility of skin folds. Assessment protocols skinfold did not have agreement when compared with DEXA
8

Análise da qualidade de vida de pacientes submetidos a abdominoplastia circunferencial após tratamento cirúrgico da obesidade mórbida / Quality of life analysis in patients submitted to circumferential abdominoplasty after surgical treatment of the morbid obesity

Wilson Cintra Júnior 05 June 2006 (has links)
INTRODUÇÃO: Os pacientes portadores de obesidade mórbida submetidos a tratamento cirúrgico para obesidade através de cirurgias desabsortivas-restritivas, após considerável perda de peso, podem apresentar excessos dermogordurosos nas várias regiões do corpo, freqüentemente associados à dificuldade de higiene pessoal e deambulação, maior incidência de infecções cutâneas, insatisfação com a imagem corporal, piora na auto-estima e nos relacionamentos profissionais e afetivos, além da piora da qualidade de vida. Naqueles pacientes com excessos dermogordurosos em abdome e flancos, e ptose da região glútea, a abdominoplastia circunferencial tem demonstrado ser uma solução cirúrgica eficaz. OBJETIVO: Avaliar as alterações na qualidade de vida dos pacientes submetidos a abdominoplastia circunferencial, nos aspectos afetivo-relacional, profissional, social e orgânico. MÉTODOS: Dezesseis pacientes do sexo feminino, que realizaram abdominoplastia circunferencial entre agosto de 2000 e janeiro de 2005, e eram acompanhadas no ambulatório de Cirurgia Plástica da Divisão de Cirurgia Plástica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, foram submetidas à entrevistas psicológicas semidirigidas, que consistiram de 31 questões, cujas respostas obtidas foram tabuladas e divididas em categorias. Utilizando-se a Escala Diagnóstica Adaptativa Operacionalizada (EDAO), e tendo como princípio norteador o critério adaptativo, as respostas foram classificadas como adequadas, pouco adequadas ou pouquíssimo adequadas. Através de notas atribuídas a cada resposta, foi possível a avaliação quantitativa nos quatro setores de funcionamento (afetivo-relacional, produtividade, sócio-cultural e orgânico) e a classificação diagnóstica das pacientes quanto à adequação. RESULTADOS: No setor afetivo-relacional, dez pacientes (62,5%) apresentaram respostas adequadas e cinco (31,25%), pouco adequadas. No setor produtividade, dez pacientes (62,5%) apresentaram respostas adequadas e quatro (25%), pouco adequadas. No setor sócio-cultural, treze pacientes (81,25%) apresentaram respostas adequadas. No setor orgânico, dez pacientes (62,5%) apresentaram valores máximos em todos os indicadores avaliados. Sete pacientes (43,75%) apresentaram adaptação eficaz e seis (37,5%), ineficaz leve. CONCLUSÕES: As análises, qualitativas e quantitativas, realizadas através da EDAO, concluiram que houve benefício efetivo aos pacientes submetidos a abdominoplastia circunferencial, nos aspectos físico, profissional, social e orgânico. / INTRODUCTION: Morbid obesity patients submitted to surgical treatment through disabsorptive/restrictive procedures, after considerable weight loss, may present skin and fat excess throughout different body regions, frequently associated with restrictions on personal hygiene and deambulation, greater incidence of skin infections, body image dissatisfaction, worsening of self-steem and of professional and affective relationships, besides down grading quality of life in general. On those patients that present skin and fat excess on the abdomen, flanks and gluteal ptosis, the circumferential abdominoplasty has demonstrated to be an effective surgical solution. OBJECTIVE: To evaluate the modifications on the quality of life of patients that underwent circumferential abdominoplasty on affective/relational, professional, social and organic aspects. METHODS: Sixteen female patients that underwent circumferential abdominoplasty between August 2000 and January 2005 were followed on the outpatient clinic of the Plastic Surgery Division of the Hospital das Clínicas of the University of São Paulo, and were submitted to semi-directed psychological interviews that consisted in 31 questions whose answers were tabulated and separated in categories. One used the Operational Adaptive Diagnostic Scale (OADS) and observing the adaptive patterns as the main criterion, the answers were classified as fairly, poorly and least poorly adequate. Through grades attributed to each answer, it was possible to evaluate quantitatively the four aspects of observation (affective/relational, professional, social and organic) and to establish a classification of the patients relative to their adaptive adequacy. RESULTS: On the aspect affective/relational, ten patients (62.5%) presented fairly adequate answers and five (31.25%) poorly adequate ones. On the productivity aspect, 10 patients (62.5%) presented fairly adequate answers and four (25%) poorly adequate ones. On the social/cultural aspect, 13 patients (81.25%) presented fairly adequate answers. On the organic aspect, 10 patients (62.5%) presented maximum grades in all evaluated criteria. Seven patients (43.75%) presented effective adaptation and six (37.5%) slightly ineffective. CONCLUSIONS: The qualitatively and quantitatively analysis made through OADS showed that there was effective benefit to the patients submitted to circumferential abdominoplasty on the physical, professional, social and organic aspects.
9

Efeitos de um programa de treinamento contra resistência sobre a composição corporal, a força muscular e a flexibilidade de mulheres idosas / Effects of resistance training program on body composition, muscle strength and flexibility of elderly women

Barbosa, Aline Rodrigues 15 February 2000 (has links)
Esse estudo analisou os efeitos de 10 semanas de treinamento contra resistência, sobre a composição corporal, a força muscular e a flexibilidade de 11 mulheres idosas (68,91 ± 5,43 anos). Um grupo de 8 idosas (65,13 ±4,09 anos) serviu como controle inativo. A força de preensão manual (ambas as mãos), o percentual de gordura corporal (dobras cutâneas e bioimpedância) e a flexibilidade (teste \"sentar e alcançar\") foram avaliados antes e após 10 semanas. A força muscular isotônica foi avaliada pelas cargas de treinamento. Após as avaliações iniciais, os indivíduos começaram o programa de treinamento que consistiu de oito exercícios (peito, costas, ombro, bíceps, tríceps, coxa, panturrilha e abdome), sem a realização de exercício para flexibilidade. O programa de treinamento resultou em aumentos significativos (p< 0,001) na força muscular isotônica, para todos os exercícios, com aumentos percentuais que variaram de 25,91% a 49,09%, para tríceps e panturrilha, respectivamente. Verificaram se aumentos significativos (p < 0,001) na força de preensão manual de ambas as mãos e também na flexibilidade no grupo submetido a treinamento. O programa de treinamento não resultou em alteração na gordura corporal avaliada por bioímpedância e equação de dobras cutâneas, contudo verificou-se redução no &#931; 8DC (p&#8804;0,01). Não foram observadas alterações no grupo controle, em nenhuma variável investigada. Conclui-se que o programa de treinamento utilizado foi eficaz para aumentar a força muscular e a flexibilidade das mulheres idosas, reduzir o &#931; 8DC, contudo não provocou redução do percentual de gordura corporal. / This study analyzed the effects of a 10-wk resistance training program on body composition, muscle strength and flexibility in 11 elderly women (68.91 ± 5.43 yr.). A control group of 8 women (65.13 ± 4.09 yr.) served as inactive controls. Hand grip strength (both hands), body fat percent (skinfold thickness and bioelectrical impedance) and flexibility ( \"sit and reach\" test) were assessed before and after 10 weeks . The isotonic muscle strength were assessed by the weight of training . After initial tests, the subjects began a training program consisting of eight exercises for all body (chest, back, shoulder, biceps, triceps, thigh, calf and abdomen), without flexibility exercises. The training program resulted in significant increase (p< 0.001) in isotonic muscle strength, for all exercises, with increases ranged from 25.91% to 49.09%, for triceps and calf, respectively. It was observed significant increase (p<0,001) in hand grip strength (both hands) and flexibility in the training group. The training program resulted in no decrease in body fat assessed by bioelectrical impedance and skinfold thickness equation, but we observed decrease in &#931; 8ST (p&#8804; 0.01). No significant changes were observed in the control group by ariy variable. In conclusion, the training program utilized was effective in increase muscle strength, flexibility and reduced &#931; 8ST. However, the training program did not reduce body fat percentage.
10

Efeitos de um programa de treinamento contra resistência sobre a composição corporal, a força muscular e a flexibilidade de mulheres idosas / Effects of resistance training program on body composition, muscle strength and flexibility of elderly women

Aline Rodrigues Barbosa 15 February 2000 (has links)
Esse estudo analisou os efeitos de 10 semanas de treinamento contra resistência, sobre a composição corporal, a força muscular e a flexibilidade de 11 mulheres idosas (68,91 ± 5,43 anos). Um grupo de 8 idosas (65,13 ±4,09 anos) serviu como controle inativo. A força de preensão manual (ambas as mãos), o percentual de gordura corporal (dobras cutâneas e bioimpedância) e a flexibilidade (teste \"sentar e alcançar\") foram avaliados antes e após 10 semanas. A força muscular isotônica foi avaliada pelas cargas de treinamento. Após as avaliações iniciais, os indivíduos começaram o programa de treinamento que consistiu de oito exercícios (peito, costas, ombro, bíceps, tríceps, coxa, panturrilha e abdome), sem a realização de exercício para flexibilidade. O programa de treinamento resultou em aumentos significativos (p< 0,001) na força muscular isotônica, para todos os exercícios, com aumentos percentuais que variaram de 25,91% a 49,09%, para tríceps e panturrilha, respectivamente. Verificaram se aumentos significativos (p < 0,001) na força de preensão manual de ambas as mãos e também na flexibilidade no grupo submetido a treinamento. O programa de treinamento não resultou em alteração na gordura corporal avaliada por bioímpedância e equação de dobras cutâneas, contudo verificou-se redução no &#931; 8DC (p&#8804;0,01). Não foram observadas alterações no grupo controle, em nenhuma variável investigada. Conclui-se que o programa de treinamento utilizado foi eficaz para aumentar a força muscular e a flexibilidade das mulheres idosas, reduzir o &#931; 8DC, contudo não provocou redução do percentual de gordura corporal. / This study analyzed the effects of a 10-wk resistance training program on body composition, muscle strength and flexibility in 11 elderly women (68.91 ± 5.43 yr.). A control group of 8 women (65.13 ± 4.09 yr.) served as inactive controls. Hand grip strength (both hands), body fat percent (skinfold thickness and bioelectrical impedance) and flexibility ( \"sit and reach\" test) were assessed before and after 10 weeks . The isotonic muscle strength were assessed by the weight of training . After initial tests, the subjects began a training program consisting of eight exercises for all body (chest, back, shoulder, biceps, triceps, thigh, calf and abdomen), without flexibility exercises. The training program resulted in significant increase (p< 0.001) in isotonic muscle strength, for all exercises, with increases ranged from 25.91% to 49.09%, for triceps and calf, respectively. It was observed significant increase (p<0,001) in hand grip strength (both hands) and flexibility in the training group. The training program resulted in no decrease in body fat assessed by bioelectrical impedance and skinfold thickness equation, but we observed decrease in &#931; 8ST (p&#8804; 0.01). No significant changes were observed in the control group by ariy variable. In conclusion, the training program utilized was effective in increase muscle strength, flexibility and reduced &#931; 8ST. However, the training program did not reduce body fat percentage.

Page generated in 0.4328 seconds