• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 448
  • 26
  • 1
  • Tagged with
  • 475
  • 264
  • 202
  • 157
  • 94
  • 77
  • 67
  • 56
  • 49
  • 46
  • 46
  • 44
  • 44
  • 44
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Scenarion och potential för energieffektivisering i Uppsala kommuns bostäder fram till år 2050 : Ett arbete inom Färdplan 2050 för ett klimatpositivt Uppsala / Scenarios and potential of the energy efficiency in Uppsala municipality housings to the year of 2050

Åkerlund, Hanna January 2014 (has links)
Syftet med detta examensarbete är att kartlägga potentialen för energieffektiviseringar i småhus och flerbostadshus i Uppsala kommun fram till 2050. Studien inkluderar både befintliga och framtida byggnader. Uppsala kommun arbetar tillsammans med flera olika organisationer i kommunen med att ta fram en ”Färdplan för ett klimatpositivt Uppsala år 2050” (kallad Färdplan 2050), detta med uppdrag av Naturvårdsverket. Målet med Färdplan 2050 är att ta fram en långsiktsprognos för hur Uppsala kommun kan minska utsläppen av växthusgaser med 45 % per invånare till år 2020 jämfört med år 1990. Detta för att sedan nå det långsiktiga målet, ett maximalt koldioxidutsläpp på 0,5 ton per invånare senast 2050. Resultaten från examensarbetet kommer ingå i Färdplan 2050 och på så sätt ligga till grund för kommunens framtida energipolitik.   I examensarbetet bestämdes tre olika framtidsscenarion: referens-, aktörs- samt ett potentialscenario. Referensscenariot beskriver en trolig utveckling av energianvändningen där en ”spontan” energieffektiviseringstakt på 0,4 % per år för småhus och 0,6 % per år för flerbostadshus antas. Aktörscenariot ska inkludera effekter av åtgärder som lokala aktörer genomför eller planerar att genomföra. För flerbostadshus innebär detta en energibesparing på 5,5 % och för småhus saknas ett riktat initiativ att göra mer än snittet i Sverige. Potentialscenariot var ämnat att baseras på energideklarationer gjorda i Uppsala kommun. Åtgärdsförslagen i energideklarationerna var tänk att ligga till grund för energieffektiviseringspotentialen. Det visade sig att åtgärdsförslagen inte var tillräckliga för att kartlägga den energieffektiviseringspotential som fanns i kommunen.   För att kartlägga potentialen för energieffektiviseringar i befintliga byggnader simulerades olika energieffektiviseringsåtgärder på ett antal typhus. Simuleringsprogrammet som användes var VIP-Energy. Simuleringarna resulterade i en potential att minska energiförbrukningen i småhus med 64 % och 45 % för flerbostadshus. Potentialen för framtida byggnader beräknades till ungefär 23 % för bostäder som byggs fram till 2030 och 22 % till år 2050.   Slutsatserna av arbetet är bland annat att BBR:s krav på energiförbrukning i byggnader är för låga för att nå klimatmålen. Simuleringarna av scenarion i LEAP visar att det finns en stor potential för energieffektiviseringar i Uppsala kommun. För att nå potentialen krävs dock mer energieffektiviseringsarbete, både i befintliga byggnader och för nybyggnationer. / The purpose of this report is to examine the energy efficiency potential in Uppsala municipality housings, from today to the year of 2050. The study includes both existing and future housings that will be built during these years. On behalf of Naturvårdsverket, Uppsala municipality cooperates with various organizations to produce an energy roadmap to the year 2050. The aim of the energy roadmap is to present a long-term plan on how the municipality should reach the environmental goals. The results from this report will be the foundation for the energy policy in the future. The report includes three future scenarios; the reference-, actor- and potential scenario. The reference scenario describes a probable development in energy use where spontaneous rate of energy efficiency measures is assumed. The actor scenario presents the effects of present and planned energy saving projects registered by local partners and the potential scenario shows the potential of reducing energy use in housings. Simulation and calculations showed a potential decrease of energy use by 64% in single-family houses, by 45% in apartment buildings and by 23% in future housings. The conclusions of the report are, among others, that BBR´s demands on energy usage are too low to reach the environmental goals and that the energy declarations were not enough to survey the energy efficiency potential. Simulations show that the potential for energy efficiency in Uppsalamunicipality are large. Though, it requires more work concerning energy saving in both existing and future housing to be able to reach the goals.
72

Studie för energieffektivisering av belysningsarmaturer : En energieffektivitetsanalys mellan två armaturtyper

Blomqvist, Henrik, Björnalm, Linus January 2016 (has links)
Syftet med studien var att undersöka de ekonomiska vinster som kan erhållas vid byte av belysningsarmaturer i en byggnad. Studien omfattar de energi- och ekonomiska besparingar som möjliggörs via ett byte från gamla T8-armaturer till LED-armaturer. Dessutom skulle kunskap kring armaturernas påverkan på elnätet i form av övertoner tas fram. Målet var därmed att ta fram en tydlig redogörande jämförelse mellan de två armaturtyperna. Studien ”Energieffektivisering av belysningsarmaturer” utfördes på uppdrag av Caverion Sverige AB men i B&B-Tools vägnar och dess lokal belägen i Ulricehamn. För att uppfylla syftet krävdes information om armaturtyperna och hur de fungerar och därmed också god kunskap kring det berörda ämnet. Armaturerna som jämförs i denna studie är en lysrörsarmatur med T8-lysrör som installerades för ca 25 år sedan samt en modern LED-armatur från leverantören Waldmann med produktnamnet Taureo. Med hjälp av ett elkvaltitetsinstrument från företaget Metrum, som är anpassat för att utföra tillförlitliga kontroller av olika elkvalitetsparametrar, bestämdes armaturernas effekt. Dessutom uppmättes armaturernas övertonshalter som visade betydligt högre övertonshalter hos lysrörsarmaturen än för LED-armaturen. Eftersom övertoner kan medföra negativa konsekvenser på såväl enskilda komponenter som på självaste elnätet, eftersträvas så låga övertonshalter som möjligt. Genom de mätningar av effekt som gjordes under studien påvisas att ett armaturbyte skulle innebära en kraftig effektminskning motsvarande en tredjedel av det nuvarande effektuttaget. Därigenom kan större energimängd sparas, cirka 52 000 kWh/år, vilket innebär en årlig kostnadsbesparing på cirka 43 000 kr. Enligt de gjorda beräkningarna erhålls en återbetalningstid på cirka 8,5 år vilket kan bedömas som god lönsamhet i och med LED-armaturernas långa livslängd.
73

Energikartläggning av en äldre fastighet : En kartläggning kring energiförbrukningen och kostnadsbesparande lösningar för en äldre fastighet

Lindgren, Rickard January 2016 (has links)
On the behalf of Norrporten in Umeå have an energy audit been made on an older part of a building. The goal has been to calculate the distribution of energy carriers in the property and to find out what the operating cost for the building is. With that in mind so have different methods to reduce energy and operating costs been examined and its effect on energy consumption. This survey analyzes ventilation, heating, water heating and climate shell of the property. Measures to reduce energy consumption due to operations in the building have not been examined. The simulation program IDA ICE was used for energy calculations. The results show that the property currently use about 150 MWh/year of heat and about 104 MWh/year of electricity. This means an annual operating cost of about 200 600 SEK. Among the largest energy consuming parts are: Heating of the facility Heating of domestic hot water Ventilating el for fan operation The total savings opportunity is apparent to about 14,600 kWh/year of electricity and about 39,600 kWh/year of district heating.
74

Energieffektivisering i befintliga byggnader : Möjligheter för Mimer att skapa lågenergihus vid ombyggnation

AL Hasan, Sheraz January 2010 (has links)
<p>Detta examensarbete fokuserar på energieffektivisering av flerbostadshus som är uppförda under 1960-talet. Eftersom sektorn bostäder och service står nuförtiden för cirka 40 % av landets totala energianvändning, så är det värt att försöka åtgärda befintliga byggnader som läcker onödig stor energi. I den här rapporten redogörs för vilka möjligheter som kan leda till minskad energianvändning i byggnader vid omfattande ombyggnation. Det finns två viktiga anledningar till varför fastighetsbolagen bör satsa på energieffektivisering vilka är ekonomin och miljön. Syftet med detta arbete är att fokusera på att minska energianvändningen i ett flerbostadshus som är beläget i Skultuna. Boendesvanor gällande hushållsel kommer inte att tas upp i denna rapport. De föreslagna åtgärderna berör endast byggnadsteknik och installationsteknik. Nybyggnation av passivhus i kvarteret Berggrottan har redovisats för att ge insikt om de olika byggnadstyperna gällande energiförbrukning och byggnadsteknik. Passivhuskonceptet har diskuterats för att ge inspiration och vetskap om hur man kan applicera passivhustekniken vid ombyggnation och för att se om det är möjligt att skapa ett lågenergihus vid ombyggnation eller inte. Den undersökta byggnaden är en av de typiska trevåningars lamellhus som har producerats i stort antal under perioden 1960-1975. Detta arbete ska fungera som ett utvecklingsunderlag för Mimer som satsar på energifrågorna och vill göra besparingsåtgärder i sina gamla flerbostadshus särskilt de som förbrukar mycket energi. De studerade förslagen har indelats i två kategorier. Den ena handlar om byggnadstekniska åtgärder, vilka är tilläggsisolering av fasader, tilläggsisolering av vindsbjälklaget och byte av fönster. Den andra handlar om installationstekniska lösningar, vilka är montering av Wanpan golvlist och installering av solfångare. Resultatet från utförda energiberäkningar visar att transmissionsförlusterna minskas från 47 % till 24 % om de föreslagna byggnadstekniska åtgärderna följs. Dessutom besparas totalt 116 700 kr/år . Till slut kan konstateras att möjligheten att skapa lågenergihus finns, men om ytterligare åtgärder införs. Det är svårt att bestämma vilka åtgärder är effektivast eftersom det beror i första hand på vilka förutsättningar som finns. Varje byggnad är unik och har sina speciella förutsättningar, så därför är det viktigt att studera den som ett helt system.</p>
75

Energianalys och energieffektivisering av en förskola : Söderskolan (Slottets förskola) i Gävle, simulering utförd genom IDA ICE 4.61

Ameen, Arman January 2014 (has links)
Bostad- och servicesektorn står för 38 % av Sveriges totala energianvändning. Av det här står bostäder och lokaler för 90 % av energianvändningen och nästan 60 % av det går till att värma upp byggnaderna och till varmvatten. Därför är det viktig att börja titta på den här sektorn och se om det finns möjlighet att spara på energianvändningen. I den här studien har en kartläggning gjorts av en gammal skolbyggnad för att kunna skapa ett underlag för energieffektiviseringsåtgärder. Genom att använda simuleringsprogrammet IDA ICE 4.61 har man skapat en basmodell av byggnaden som då används som simuleringsbas. Basmodellen har jämförts med fjärrvärmekostnader för att kunna verifieras. Därefter har man lagt in energieffektiviserar och tittat på vilka besparingar man har kommit fram till. Resultatet av den här studien visade att i den här byggnaden så är den mest effektiva åtgärden isolering av taket till vinden.
76

Simuleringsmodul för energiflödesanalys av ett hybridfordons drivlina / Simulation Module for energy flow analysis in a hybrid vehicle power train

Olofsson, Per January 2014 (has links)
No description available.
77

Energieffektivisering av flerbostadshus : Energieffektiviseringspotentialen undersöks i ett kvarter med flerbostadshus från 1940-talet

Blom, Elin, Johnsson, Jesper, Klit, Max January 2017 (has links)
The thesis cover the energy efficiency of a multi-family house from the 1940s situated in Halmstad. As the energy performance in buildings gets better and the energy solutions aregetting smarter, the requirements will be higher for new construction. On the other hand, realestate from the 40's remains the same and are often operated with the same heating systemsas those when originally put into operation.The purpose of the report is to investigate the potential for energy efficiency in olderbuildings as well as the financial consequences of the energy-efficient solutions.The thesis is written on behalf of Halmstad Fastighets AB (HFAB), who intends to evaluatethe neighborhood in 2019 and subsequently decide on the future of the housing area. Thereport is based on this area as a reference and the action proposals presented in the report aresimulated in this housing area. The housing area was commissioned in 1943 and consists offive houses, one longer structure and four point-houses, which makes it the first multiresidentialarea owned and operated by the company. HFAB has an internal target of 75 kWh/m2, year for the entire property stock at the turn of the year 2050, which represents a targetvalue that the report intends to achieve.The report is divided into two parts, the first describing the buildings' current energy systemfrom a theoretical and technical point of view and including an energy survey on existingenergy flows for the properties. The energy survey then constitute the foundation for thesecond part, where theory and technical construction of the systems installed with the actionproposals are described together with reports on the theory for energy saving calculations.The results show that a renovation and investment with modern technology and energyefficient solutions has a major impact on the final energy use, even reaching lower specificvalues than those defined as internal goals within the company. Energy-efficient investmentscan also be a profitable investment from an economic point of view, providing additionalincentives for the property owner. / Detta examensarbete behandlar energieffektivisering av ett flerbostadshuskvarter från 1940-talet beläget i Halmstad. Energieffektivisering är ett högst aktuellt ämne och i takt med attenergiprestanda i byggnader blir bättre och energilösningarna smartare så kommer kraven blihögre för nybyggnationer. Däremot står många fastigheter från 40-talet talet kvar och drivsmed samma uppvärmningssystem sedan det tagits i drift.Syftet med rapporten är att undersöka potentialen för energieffektivisering i äldre hus samtvilka ekonomiska konsekvenser de energitekniska lösningarna står för.Examensarbetet har genomförts på uppdrag av Halmstad Fastighets AB (HFAB), som avserutvärdera energianvändningen i kvarteret Framtiden år 2019 och sedermera ta beslut ombostadsområdets framtid. Rapporten utgår med detta område som referens och deåtgärdsförslag som tas fram i arbetet simuleras på detta bostadsområde. Området består avfem huskroppar, en länga och fyra punkthus, och togs i drift 1943, vilket gör området tillHFABs första flerbostadsområde. HFAB har ett internt mål på 75kWh/m2, år för hela dessfastighetsbestånd vid årsskiftet 2050, vilket är en gräns rapporten avser att uppnå.Rapporten är uppdelad i två delar där den första beskriver fastigheternas nuvarandeenergisystem ur en teoretisk och teknisk synpunkt samt innehåller en energikartläggning påbefintliga energiflöden för fastigheterna. Energikartläggningen lägger sedan grunden förandra delen, där teori och teknisk uppbyggnad av de system som installeras medåtgärdsförslagen beskrivs tillsammans med en redovisning av teori för beräkningar avenergibesparingar.Resultat visar att renovering och investering med modern teknik och energieffektivalösningar har stor inverkan på den slutgiltiga energianvändningen, vilken t.o.m. kanunderskrida de interna målen satta inom HFAB. Energieffektiva investeringar kan även varaen lönsam investering ur en ekonomisk synpunkt, vilket ger ytterligare ett incitament förfastighetsägaren.
78

Kan restvärme från rörtillverkning tas tillvara till intern fjärrvärme? : En fallstudie för Rörverk 2012 på Sandvik ABs nordvästra industriområde i Sandviken i samarbete med ÅF.

Nordin, Malin January 2016 (has links)
Den globala uppvärmningen ökar i takt med utsläppen från det växande konsumtionssamhället och världen står inför en stor utmaning i att bromsa den negativa utvecklingen. Stålindustrin i Sverige står för industrins näst största energianvändning, efter massaindustrin, och stor del energi går förlorad som restvärme. Restvärme kan definieras som ”värme bunden till vätskor och gaser som släpps ut från en process till omgivningen och som inte utnyttjas”. Ett sätt att ta tillvara restvärme är genom fjärrvärme. En önskad temperatur för att restvärme direkt ska kunna växlas till ett fjärrvärmenät är enligt tidigare studier 90 oC. Lägre temperaturer kan uppgraderas med värmepump för att användas till ändamålet. Examensarbetets syfte var att identifiera potentialen för att använda restvärme från Rörverk 2012 till intern fjärrvärme inom Rörverk 68, Rörverk 98, Rörverk 2012 och transsportavdelningens lokaler. Metoden för arbetet har varit en litteraturstudie och en fallstudie baserad på intervjuer och flödes- och temperaturmätningar i Rörverk 2012. Några tekniska lösningar har inte undersökts närmare. För fallstudien har kartlagts vilka energiflöden som går in i byggnaden och vilka som går ut, även storleken på dessa har bestämts. Både fastighetsrelaterade och processrelaterade flöden har identifierats. Värt att nämna är att lokalen har övertemperaturer under stora delar av året och att den rymmer en ugn som håller 80 oC i ytan dygnet runt, vilket ger ett stort värmetillskott. De höga temperaturerna i lokalen ökar drivkraften för värmetransport genom väggar, vilket kallas transmissionsförluster och okontrollerad ventilation via otätheter och vädring. Undersökningen visar att inte några av energiflödena ut ur byggnaden anses tillräckliga för återvinna värme ur. Om energi däremot skulle tas tillvara ur den varma inomhusluften skulle problemet med övertemperatur i lokalen lösas och drivkrafterna för transmission och okontrollerad ventilation skulle minska, vilket även ger mindre energiförluster. Det finns potential att ta tillvara ca 1,1 GWh ur inomhusluften/år. Detta skulle kunna göras genom att temperaturen uppgraderas med värmepump och förs över till värmesystemet, som binds samman med de andra byggnaderna. Detta skulle ge ökad komfort i lokalen, samt minskad energianvändning för uppvärmning i byggnaderna omkring. Fortsatt undersökning för teknisk lösning behöver göras. / The global warming increases together with the release from the growing consumer society andthe world have a great challenge to stop this negative development. The steel industries have the second highest energy use, the highest user is the mass industries, and a large part of the energy is lost as waste heat. Waste heat can be defined as “heat bound to fluids and gases that is released from a process to the environment and can ́t be used.One way to use the waste heat is through district heating. The temperature to wish for if you want to use it for district heating is according to studies 90oC. Lower temperatures can be upgraded by a heat pump for usage in this purpose.The purpose of this thesis was to identify the possibilities to use waste heat from Rörverk 2012 to local district heating at Rörverk 68, Rörverk 98 and Rörverk 2012 and the transport department. The method for the thesis has been to study literature and a case study based on interviews and measurements at Rörverk 2012. Any technical solutions hasn ́t been looked at.For the case study it has been mapped which energy flows who enters the building and which who leaves, the sizes of them has also been mapped. Both real estate and process related flows have been identified. Worth a mention is that the building has an over temperature during large parts of the year and it contains an oven which has a temperature of 80C at the surface, which gives a great energy addition. The high temperatures in the building increases the driving force for transporting heat through walls, which is called transmissions losses and uncontrolled ventilation through leaks and aeration.This research shows that neither of the energy flows out of the building is seen as big enough to recycle heat from. If energy should be taken care of through the hot indoor air it would solve the problem with over temperature inthe building and the driving forces for transmission and uncontrolled ventilation would decrease, which would lead to smaller energy losses. It would also save energy. It is possible to take care of approximately 1.1 GWh through the indoor air each year. This could be done through an upgrade of the temperature by a heat pump and is transmitted to the heating system, which is connected to the other buildings. This would give a better comfort in the building, and decreased energy usage for the nearby buildings. Further investigations for technical solutions are needed.
79

Effektivisering av rökgaskondensorn : En undersökning av att kyla inkommande fjärrvärmeretur

Topic, Sinisa January 2016 (has links)
This project has been executed as an assignment by Sundsvall Energi AB with the purpose of increasing the efficiency of the flue gas condenser by cooling the incoming district heating return before the flue gas condensing exchanger. The flue gas condenser is part of the heat production. The first production unit is the waste boiler where the steam can be distributed between production of electricity and heat production, depending on how large the costumers needs of electricity and heat are. When the customers’ needs are less than Korstaverkets maximum production, an addition of heat from the flue gas condenser means that a larger portion of the steam can go to the turbine and increase the production of electricity. When the customer’s needs are larger than Korstaverkets maximum capacity, a contribution from the flue gas condenser means that Korstaverket can purchase less heat from SCA (Ostrand and Ortviken). The benefit of cooling the district heating return is that more heat and electricity can be produced. In the early stages of the project, literature and the Internet were used to get a basic understanding of the assignment. The supervisor and the staff at Korsta have given drawings and data of the power plant process, and also given advice regarding the process. Product data sheets from suppliers have been used for doing calculations and for getting information about the construction. Scientific articles and literature were used to get facts and formulas. The study has shown that the additional cooling of the district heating return has contributed to an increased efficiency of the flue gas condenser, from 0.9 % with an average flow of the deionized water to 17.2 % with a maximum flow of the deionized water.  The exam work has shown how complicated an energy system can be. The process can be more complicated then what the drawings show, because a profitable solution in one part of the process can lead to deterioration in another part of the process. The calculations show that the major factor that’s influencing the cooling is the deionized waters flow into the new heat exchanger. The repayment period can get short. High flows generate a profit after only a couple of months, while low flows of 1 liter/second take up to 3.5 years with KE Therms brazed heat exchangers and 2.5 years with Tranters gasketed heat exchangers.
80

Energibesparing i industrilokal : En IDA ICE studie

Jakobsson, Anton January 2016 (has links)
Energieffektivisering blir en allt viktigare åtgärd på äldre fastigheter i takt med att kostnaden för energi stiger. Att energieffektivisera kan beskrivas som att uppnå samma resultat med mindre energiåtgång, för brukaren resulterar detta i lägre kostnader lagda på inköp av energi och för samhället resulterar detta i en minskad belastning på miljö och klimat. I mitt examensarbete som du håller i din hand har jag undersökt en industrilokal belägen på Teg i Umeå där jag med simuleringsprogrammet IDA ICE simulerat olika energieffektiviseringsåtgärder och hur de skulle påverka byggnadens förbrukning av energi. Åtgärderna som simulerats är: Tilläggsisolering av väggar och tak, byte till FTX-system, byte av fönster samt byte av dörrar och garageportar till mer välisolerade alternativ. Arbetet består till stor del av litteraturstudie och simuleringsprogrammet där en modell av huset har konstruerats för att efterlikna dess verkliga motsvarighet till så stor grad som möjligt. Efter detta har åtgärderna tillämpats och sedan simulerats för att till sist jämföras med referenshusets simulering. Resultatet visar att samtliga åtgärder skulle sänka energiförbrukningen av byggnaden i någon mån. Den största besparingen på 49,3 % skulle fås om man byter ventilationssystem medan den minsta besparingen, 0,7 %, fick man genom att byta fönster. / Reducing the energy consumption in older buildings is growing to be more important by each passing day as the cost of energy rises and political strides are made to limit the amount of energy used for various purposes. To optimize the use of energy in a building can be described as getting the same end result with a lower amount of spent energy, for the user this is an economic victory as he doesn’t have to spend as much money on heating his building while society gains a reduced impact on the environment and climate. In this thesis that you hold in your hands I have investigated an industrial building located in Teg, Umeå where I utilized the simulation software IDA ICE to simulate the buildings energy usage and the effects of various energy optimization/saving measures if implemented. The measures simulated are: Additional insulation for walls and roof, the switch to a ventilation system with a heat recovery unit, switching to well insulated windows, and switching the doors and garage doors to well insulated units. The work has mostly been done through studies of literature and IDA ICE where a model of the building has been constructed according to the specifications of the real world counterpart. The results from the various simulations are then compared with each other and the reference case. The results showed that all energy saving measures would result in a lowered use of energy. The biggest saving was gained from the changing out the ventilation system which resulted in a 49,3 % reduction whilst changing windows only resulted in a 0,7 % reduction.

Page generated in 0.0331 seconds