• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 199
  • 27
  • 10
  • 6
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 277
  • 84
  • 61
  • 60
  • 52
  • 45
  • 43
  • 40
  • 34
  • 31
  • 31
  • 31
  • 28
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estudo comparativo entre diferentes cimentos endodônticos em relação à resistência de união do conjunto cimento resinoso/pino de fibra de vidro à dentina radicular / Comparative study between different endodontic sealers in relation to the bond strength of the resin cement / fiberglass post complex to the root dentin

Soares, Isadora Mello Vilarinho 03 August 2018 (has links)
O objetivo do estudo foi avaliar, comparativamente, a influência do cimento biocerâmico EndoSequence BC a diferentes cimentos endodônticos sobre a resistência de união do conjuno cimento resinoso/pino de fibra de vidro à dentina radicular. Setenta e dois dentes caninos selecionados tiveram a coroa seccionada transversalmente e o remanescente radicular padronizado em 17mm. O canal radicular foi preparado com Reciproc R50 e NaOCl 1%. Os espécimes foram distribuídos conforme o cimento obturador utilizado (n=12): G1-controle (sem cimento); G2- óxido de zinco e eugenol (EndoFill) G3- hidróxido de cálcio (Sealapex); G4- resina epóxi (AHPlus); G5-resina epóxi e hidróxido de cálcio (Sealer Plus) e G6- biocerâmico (EndoSequence BC). Decorridas 48h da obturação, as raízes foram desobturadas e preparadas para receber o pino de fibra de vidro. Após secagem do canal, os pinos foram cimentados com Panavia F 2.0. Dez raízes de cada grupo foram seccionadas transversalmente para obtenção dos slices. O primeiro slice de cada terço foi submetido ao teste de resistência de união (push-out) e padrão de falha. No segundo slice foi avaliada a interface adesiva dentina/cimento resinoso, por meio de microscopia de varredura confocal a laser (MVCL). Dois espécimes de cada grupo não tiveram o pino cimentado no canal radicular e foram destinados à microscopia eletrônica de varredura para observação de remanescente de material obturador na superfície dentinária. Os dados referentes à resistência de união foram submetidos ao teste Shapiro-Wilk, seguido de ANOVA two way. Os dados referentes à MVCL foram analisados pelo teste Kruskal-Wallis seguido pelo teste Dunn ( = 5%). Os grupos controle e AHPLus apresentaram os maiores valores de RU (p<0,05). Os cimentos EndoSequence BC, Sealer Plus e Sealapex apresentaram os valores intermediários de RU, sem diferença estatística entre eles. O cimento EndoFill apresentou os menores valores de RU com diferença estatisticamente significante em relação aos demais grupos (p<0,05). Quanto aos terços radiculares, os maiores valores de RU foram observados no terço cervical (p<0,05). As imagens de MEV demonstraram no geral, presença de poucos remanescentes de material obturador na superfície radicular em todos os grupos. Quanto a análise da interface cimento resinoso/dentina, a maioria dos grupos apresentou adaptação razoável, com exceção do EndoFill. Concluiu-se que os cimentos endodônticos Endosequence BC, Sealapex, Sealer Plus e EndoFill influenciaram negativamente a RU do conjunto pino/cimento resinoso à dentina radicular / The aim of this study was to compare the influence of EndoSequence BC bioceramic sealer on the bond strength (BS) of resin cement/fiber post in root canals filled with different sealers. The coronary of seventy-two canines were removed and the root length standardized at 17mm. The root canal was prepared with Reciproc R50 and 1% NaOCl. The specimens were distributed according to the filling material used (n=12): G1- control (no sealer); G2- zinc oxide and eugenol (EndoFill) G3- calcium hydroxide (Sealapex); G4- epoxy resin (AHPlus); G5- epoxy resin and calcium hydroxide (Sealer Plus) and G6- bioceramic (EndoSequence BC). Later forthy eight hours, the roots were prepared to insert the fiberpost. Fiberposts were attached with Panavia F 2.0. Ten roots of each group were sectioned transversely, obtaining slices of cervical, medium and apical root canal thirds. The BS of the first slice of each third was evaluated by push-out test and failures was analyzed by stereo microscope. The interface between dentin wall/resin cement of the second slice was evaluated by confocal laser microscopy (CLM). Two specimens from group were not restored with fiberpost, and assigned to scanning electron microscopy (SEM) to analyze the remaining material on the dentin surface. Data on the bond strength were submitted to the Shapiro-Wilk test, followed by two way ANOVA. The CLM data were submitted to the Kruskal-Wallis and Dunn tests ( = 5%). The control and AHPLus groups had the highest RU values (p <0.05). The EndoSequence BC, Sealer Plus and Sealapex sealers presented the intermediate values of RU, with no statistical difference between them. EndoFill sealer presented the lowest values of RU with a statistically significant difference in relation to the other groups (p <0.05). Regarding root thirds, the highest BS values were observed in cervical third (p <0.05). SEM images showed presence of few remaning filling material on the root surface in all groups. Regarding the dentine/resin cement interfaces analyzes most of the groups presented average adaptation, unless the G2. It was concluded that Endosequence BC, Sealapex, Sealer Plus and EndoFill endodontic sealers poor influenced the BS of the fiber post/resin cement in root canal dentin
82

Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados / Evaluation of the removal of different filling materials using reciprocating system followed by two supplementary techniques in flattened root canals

Crozeta, Bruno Monguilhott 18 April 2018 (has links)
O objetivo do presente estudo foi avaliar, por meio de microtomografia computadorizada (micro-CT), o volume de remanescente de diferentes materiais obturadores (AH Plus e BC Sealer), após o uso do instrumento R50 e de técnicas complementares (inserto ultrassônico e instrumento XP-endo Finisher R) em canais radiculares ovais. Vinte e oito raízes distais de molares inferiores, com canal único e oval, foram selecionadas por micro-CT, preparados com instrumento R40 (40.06), e obturados com os seguintes cimentos: AH Plus (n = 14) e BC Sealer (n = 14), e submetidos à ciclagem térmica. Em seguida foi realizada a remoção inicial com R50 e os dentes foram escaneados no micro-CT para determinação do volume remanescente inicial de material obturador, e posterior complementação com inserto ultrassônico (n = 7) ou XP-endo Finisher R (n = 7). Os espécimes foram novamente escaneados, e a partir do volume inicial de material obturador (volinicial) e volume de material obturador remanescente (volrem) em mm3, obteve-se a % de volume de material remanescente após as técnicas de complementação (%volrem=volrem×100/volinicial). Para a análise qualitativa, as imagens de MEV e os modelos tridimensionais obtidos por micro-CT, foram avaliados em relação à presença/ausência e localização do remanescente de material obturador nos canais radiculares. Os dados de %volrem e volume remanescente de material obturador após o uso do instrumento R50 (%volR50) foram comparados pelo teste T, e os dados de %volrem foram submetidos ao teste ANOVA, seguido de teste de Tukey (nível de probabilidade de 95%). Considerando o canal como um todo, as técnicas de complementação promoveram redução significativa do volume remanescente de material obturador, sendo que menores valores foram observados quando utilizado o inserto ultrassônico (8,93 ± 6,12) em relação ao XP-endo Finisher R (16,26 ± 14,71) (P = 0,043). Quanto aos cimentos, pode-se observar que o BC Sealer apresentou maiores quantidades de remanescente (18,87 ± 13,42) quando comparado ao cimento AH Plus (6,33 ± 4,25) (P < 0,001). Em relação à avaliação por terços radiculares, observou-se que quando utilizado o instrumento XP-endo Finisher R, não houve diferença do volume de material remanescente entre os terços, independente do cimento obturador utilizado (P > 0,05). Entretanto, ao se utilizar inserto ultrassônico e cimento AH Plus, maiores valores de volume de material remanescente foram observados no terço apical (23,08 ± 18,1) (P < 0,001), e quando utilizado o BC Sealer, no terço médio (15,53 ± 6,0) (P = 0,022). Conclui-se que as técnicas de complementação aumentaram a remoção de material obturador, entretanto, nenhuma das técnicas removeu por completo o material obturador do canal radicular, principalmente quando o dente foi obturado com o cimento BC Sealer / The aim of the present study was to evaluate, by micro-computed tomography (micro-CT), the remaining volume of different filling materials (AH Plus and BC Sealer) after using the R50 instrument and supplementary techniques (ultrasonic insert and XP-endo Finisher R instrument) in oval-shaped root canals. Twenty-eight distal roots of mandibular molars with single and oval-shaped canals, verified by micro-CT, were prepared with R40 instrument (40.06), and filled with the following sealers: AH Plus (n = 14) and BC Sealer (n = 14), and subjected to thermocycling. Then, the initial removal was performed with R50 and the samples were scanned in micro-CT to determine the initial remaining filling material volume, and subjected to the supplementary techniques with ultrasonic tip (n = 7) or XP-endo Finisher R (n = 7). The specimens were again scanned, and the initial volume of filling material (volinitial) and the final volume of filling material after the supplementary techniques (volfinal), obtained in mm3, were used to calculate the volume % of remaining filling material (%volrem=volrem×100/volinitial). For the qualitative analysis, the SEM images and the three-dimensional models obtained by micro-CT were evaluated regarding the presence/absence and location of the remaining filling material in the root canals after retreatment. The data of %volrem and volume of the remaining filling material after R50 (%volR50) were compared by the T test, and the %volrem data were submitted to the ANOVA and Tukey tests (95% probability level). Considering the entire root canal, the supplementary techniques promoted significant reduction of the volume of the remaining filling material, and lower values were observed for the ultrasonic tip (8.93 ± 6.12) when compared to XP-endo Finisher R (16.26 ± 14.71) (P = 0.043). Regarding the different sealers, BC Sealer presented higher amounts of remaining material (18.87 ± 13.42) when compared to AH Plus (6.33 ± 4.25) (P <0.001). The evaluation by root thirds showed that when the XP-endo Finisher R instrument was used, there was no difference in the volume of remaining material between the thirds, regardless the sealer used (P > 0.05). However, when using ultrasonic tip and AH Plus, higher values were observed in the apical third (23.08 ± 18.1) (P <0.001), and when the BC Sealer was used, in the middle third 15.53 ± 6.0) (P = 0.022). It was concluded that supplementary techniques increased the removal, however, none of the techniques completely removed the root canal filling material, especially when the tooth was filled with BC Sealer. with R40 instrument (40.06), and filled with the following sealers: AH Plus (n = 14) and BC Sealer (n = 14), and subjected to thermocycling. Then, the initial removal was performed with R50 and the samples were scanned in micro-CT to determine the initial remaining filling material volume, and subjected to the supplementary techniques with ultrasonic tip (n = 7) or XP-endo Finisher R (n = 7). The specimens were again scanned, and the initial volume of filling material (volinitial) and the final volume of filling material after the supplementary techniques (volfinal), obtained in mm3, were used to calculate the volume % of remaining filling material (%volrem=volrem×100/volinitial). For the qualitative analysis, the SEM images and the three-dimensional models obtained by micro-CT were evaluated regarding the presence/absence and location of the remaining filling material in the root canals after retreatment. The data of %volrem and volume of the remaining filling material after R50 (%volR50) were compared by the T test, and the %volrem data were submitted to the ANOVA and Tukey tests (95% probability level). Considering the entire root canal, the supplementary techniques promoted significant reduction of the volume of the remaining filling material, and lower values were observed for the ultrasonic tip (8.93 ± 6.12) when compared to XP-endo Finisher R (16.26 ± 14.71) (P = 0.043). Regarding the different sealers, BC Sealer presented higher amounts of remaining material (18.87 ± 13.42) when compared to AH Plus (6.33 ± 4.25) (P <0.001). The evaluation by root thirds showed that when the XP-endo Finisher R instrument was used, there was no difference in the volume of remaining material between the thirds, regardless the sealer used (P > 0.05). However, when using ultrasonic tip and AH Plus, higher values were observed in the apical third (23.08 ± 18.1) (P <0.001), and when the BC Sealer was used, in the middle third 15.53 ± 6.0) (P = 0.022). It was concluded that supplementary techniques increased the removal, however, none of the techniques completely removed the root canal filling material, especially when the tooth was filled with BC Sealer
83

Estudo da permeabilidade, limpeza e contaminação do sistema de canais radiculares, após o preparo químico-cirúrgico e aplicação de laser de alta intensidade / Study of the variation of permeability, cleaning and contamination of the root canal system after preparation and application of highintensity laser

Salgado, Ricardo Julio Cabrales 17 April 2009 (has links)
A importância do aumento da permeabilidade e da limpeza da dentina radicular está ligada à melhora da sanificação e obturação do sistema de canais radiculares. Este estudo teve como objetivo, avaliar as variações da permeabilidade dentinária radicular de dentes humanos, após o preparo químico-cirúrgico e irradiação com laseres de Er: YAG, Nd:YAG, por meio da utilização do radioisótopo 99mTc livre, assim como, analisar, valendo-se da microscopia eletrônica de varredura (MEV) a limpeza, contaminação e aderência bacteriana valendo-se de inoculação de Enterococcus faecalis. Trinta raízes palatinas de primeiros pré-molares superiores humanos hígidos e foram preparadas pela técnica seriada. Posteriormente, foram divididas, aleatoriamente, em 3 grupos experimentais com 10 raízes cada: G1 - controle, G2 - irradiação com laser de Er:YAG e G3 - irradiação com laser de Nd:YAG. As amostras preparadas receberam quantidade suficiente de 99mTc livre no interior do canal radicular para o prenchimento do mesmo e colocadas em tubos de ensaio contendo 1mL de solução salina. Após 1 hora, a contagem do isótopo radioativo (99mTc) foi realizada. Findo esse período, 3 raízes foram processadas para análise da limpeza dentinária radicular por MEV e os canais radiculares das 7 raízes restantes foram contaminados com Enterococcus faecalis por 21 dias. A presença e aderência microbiana foram constatadas e avaliadas por fotomicrografias eletrônicas. O tratamento estatístico dos dados permitiu concluir que a o G3 provocou uma diminuição significativa da permeabilidade dentinária radicular; o G2 e o G1, em relação à permeabilidade dentinária radicular, não apresentaram diferença estatisticamente significante em nível de 5%; o G2 mostrou-se eficiente na limpeza das paredes dentinárias do canal radicular e, o G1 apresentou os menores índices de aderência e contaminação da parede dentinária radicular, nos diferentes terços avaliados, sendo maior no G2, seguido pelo G3. / The permeability increasing and the cleanliness of root dentin walls are important to improve the sanitization and root canal filling. Thus, this study aimed to evaluate the variations of root dentin permeability of human teeth, after endodontic preparation followed by Er:YAG and Nd:YAG laser irradiation, using free Technetium-99m radioisotope (99mTc) as tracer. Additionally, SEM images were analyzed to evaluate the cleanliness of dentin walls and possible bacterial adhesion after Enterococcus faecalis inoculation. Thirty palatal roots of human first pre-molars were prepared by conventional technique. Therefore, the sample were randomly divided into 3 experimental groups with 10 teeth each: G1 - control, G2 - Er:YAG laser irradiation and G3 - Nd:YAG laser irradiation. Samples were filled with free 99mTc and placed in test tubes containing 1ml of saline solution. After 1 hour, the radioactive isotope (99mTc) was counted. After that, 3 roots were processed for analysis of dentin cleaning through SEM images and the 7 remaining roots were infected with Enterococcus faecalis for 21 days. The microbial presence and adhesion were verified and evaluated by SEM. After the statistical treatment (ANOVA), it was concluded that Nd:YAG irradiation significantly decreased dentin permeability. Er:YAG irradiation showed significant differences in cleaning efficacy and the G1 (control) had the lowest rates of adherence and contamination of dentin walls, followed by the G3 and G2.
84

Determinação do pH e da liberação de íons cálcio de três cimentos endodônticos quando utilizados em obturações, em conjunto com guta-percha, e da qualidade das mesmas. Avaliação realizada em longo prazo / Determination of pH, calcium ion release, and overall quality of three endodontic cements used in obturations with guta-percha. A long term evaluation

Minotti, Paloma Gagliardi 11 May 2015 (has links)
O objetivo deste estudo foi avaliar o pH e a liberação de íons cálcio dos cimentos AH Plus, MTA Fillapex e Sealapex, em diferentes períodos, quando empregados em obturações de canais radiculares, bem como, a qualidade das obturações, após 1 ano de realizadas. O pH e a liberação de íons cálcio foram avaliados por meio de um peagômetro e espectrofotômetro de absorção atômica, respectivamente. A qualidade das obturações foi avaliada por meio de um estereomicroscópio. Cento e vinte e quatro pré-molares inferiores humanos extraídos, unirradiculados, foram divididos em 01 grupo controle e 02 grupos experimentais, de acordo com a padronização do diâmetro do forame apical. Em seguida, os 02 grupos experimentais foram divididos em 4 subgrupos, considerando as técnicas de instrumentação e obturação empregadas. Após o preparo dos canais radiculares cada subgrupo teve o número de dentes divididos por dois, formando novos subgrupos, de acordo com os cimentos obturadores utilizados. Imediatamente após a obturação, a raiz de cada dente foi imersa em 15 mL de água ultrapura para avaliação do pH e liberação de íons cálcio nos seguintes períodos: 1 h, 1, 3, 7, 30, 180 e 365 dias, após a obturação. Após o período de 1 ano, os dentes foram seccionados transversalmente a 2, 4, 6 mm do forame apical para análise da qualidade das obturações, analisando-se a porcentagem de cimento, guta-percha e espaços vazios na massa obturadora. Os cimentos apresentaram pH neutro, porém, aos 180 dias, os valores mostraram um ligeiro aumento quando utilizados em canais com forames de diâmetro 0,25 mm. Quando utilizados em canais com forames de diâmetro 0,45 mm, o pH mostrou-se com valores maiores para todos os períodos sem distinção do cimento. Todos os cimentos liberaram íons cálcio, com menores valores para o AH Plus. Na estereomicroscopia, observaram-se variações nas porcentagens de cimento e guta-percha, considerando-se os diâmetros foraminais e técnicas obturadoras, e porcentagem insignificante de espaços vazios. / The objective of this study was to evaluate the pH and calcium ion release of AH Plus, MTA Fillapex and Sealapex cements at different time periods when used in root canal obturations, as well as the quality of the obturations one year after being performed. The pH and calcium ion release were evaluated by means of a pH meter and an atomic absorption spectrophotometer, respectively. The quality of the obturations was evaluated using a stereomicroscope. One hundred and twenty-four extracted human uniradicular mandibular premolars were divided into 1 control and 2 experimental groups, according to the standardization of the apical foramen diameter. Next, the 2 experimental groups were divided into 4 subgroups, considering the instrumentation techniques and obturations employed. After the preparation of the root canals, each subgroup had the number of teeth divided by two, forming new subgroups, according to the sealers used. Immediately after the obturation, the root of each tooth was immersed in 15 mL of ultrapure water for the evaluation of the pH and calcium ion release in the following time periods: 1 hr, 1, 3, 7, 30, 180 and 365 days after the obturation. After the period of one year, the teeth were transversely sectioned at 2, 4 and 6 mm from the root apex to examine the quality of the obturations, analyzing the percentage of cement, gutta-percha and voids in the obturator mass. The cements presented a neutral pH, which showed slightly increase as of 180 days when used in canals with foramens of 0.25 mm diameters. When used in canals with foramens with diameters of 0.45 mm, the pH presented higher values in all periods for all cements. All cements released calcium ions, with lower values for the AH Plus. In the stereomicroscopy, there were variations in the percentages of cement and gutta-percha, considering the foraminal diameters and obturation techniques and an insignificant percentage of voids.
85

Avaliação do desempenho e alteração de superfície das limas Wave One e One Shape no decorrer do número de usos / Performance and change surface of files Wave One and One Shape during the number of uses

Pires, Márcia Virginia Morante Porto 17 March 2015 (has links)
Os sistemas de lima única constituem a mais recente tecnologia no que se refere ao preparo dos canais radiculares, e vem sendo objeto de estudo sob diversos aspectos. Uma das preocupações referentes aos sistemas automatizados é a manutenção da qualidade e segurança nos preparos quando da reutilização do instrumento. Este estudo teve como objetivo avaliar as alterações de superfície de dois sistemas de lima única - Wave One e One Shape - e seu desempenho através do tempo de preparo no decorrer dos usos. Duzentos condutos de molares inferiores humanos extraídos foram instrumentados com 10 limas Wave One e 10 limas One Shape, acompanhados de irrigação com 10 ml de Hipoclorito de Sódio 2.5%. Cada instrumento foi utilizado por 10 vezes. Os tempos para o preparo completo do canal foram registrados por um cronômetro digital e anotados em tabelas. Para avaliação em microscopia eletrônica de varredura as limas novas foram observadas assim que removidas da embalagem. Após as utilizações, os instrumentos foram limpos, esterilizados em autoclave e observados após 2, 6, 8 e 10 usos. Três avaliadores calibrados observaram as fotomicrografias e registraram de acordo com os scores propostos a presença ou ausência de alterações superficiais. O teste Kappa de concordância entre os avaliadores apresentou maioria de resultados ótimo a moderado (?=5%). Os dados referentes à avaliação das imagens foram submetidos ao teste Wilcoxon-Mann-Whitney com nível de significância de 5% (?=5%). As alterações mais observadas foram aplainamento e microcavidade. O crack foi observado nos dois instrumentos sendo significante a partir do sexto uso para Wave One e do décimo para One Shape. Os dados relativos aos tempos de preparo foram submetidos à análise estatística pelos testes Wilcoxon-Mann-Whitney, ANOVA e Mc-Nemar com nível de significância de 5% (?=5%). Os tempos de preparo registrados para One Shape foram inferiores aos tempos para Wave One. O uso influenciou os tempos de preparo sendo observado um aumento significativo para os dois instrumentos. Um instrumento One Shape fraturou mas a ocorrência não foi estatisticamente significante. / Single-file systems are the most recent technology in regard to the preparation of root canals and have been studied in several ways. One of the concerns related to automated systems is maintaining quality and safety in preparation when the instrument is reused. This study\'s aim was to evaluate the changes on the surface of two single-file systems - Wave One and One Shape - and their performance through preparation time over the uses. Two hundred root canals of extracted human molars were instrumented with 10 Wave One files and 10 One Shape files, followed by irrigation with 10 ml of sodium hypochlorite 2.5%. Each instrument was used 10 times. The time required to complete each root canal was measured by a digital stopwatch and recorded in tables. New unused files were analysed using a scanning electron microscope. After used, the instruments were cleaned and sterilized, then observed after 2, 6, 8 and 10 uses. Three calibrated evaluators observed these SEM images and listed according to the suggested scores the presence or absence of changes on the surface. The Kappa test showed mostly results from moderate to great (? = 5%). The data relating to evaluation of images was submitted to the Wilcoxon-Mann-Whitney test with a significance level of 5% (? = 5%). The most frequent changes were blunt edges and microcavities. Cracking was observed in both instruments being significant in Wave One after the sixth use and in One Shape after the tenth use. Data on preparation times were statistically analysed by the Wilcoxon-Mann-Whitney, ANOVA and Mc-Nemar tests with a significance level of 5% (? = 5%). Regarding the working time taken to shape the canals, One Shape was significantly faster than Wave One. The preparation time was affected by the number of file use increasing significantly on both instruments. A One Shape instrument fractured but the finding was not statistically significant.
86

Identificação das características microbiológicas de canais radiculares de dentes permanentes jovens portadores de infecção primária / Identification of microbiological characteristics of root canal of young permanent teeth patients with primary infection

Carvalho, Karla Baumotte de 22 May 2009 (has links)
Em condições de normalidade o cemento e o esmalte atuam como barreira protetora da dentina e do tecido pulpar. Entretanto fatores etiológicos mecânicos, químicos e microbianos podem determinar a perda dessa proteção, conseqüentemente expondo a dentina e, eventualmente, o tecido pulpar ao ambiente bucal, viabilizando sua contaminação. O complexo dentino-pulpar pode reagir de diversas formas a presença de microorganismos, entretanto, quando alterações inflamatórias irreversíveis enfim sucedem-se provocam uma desordem tecidual na região periapical denominada de periodontite apical. A terapia das periodontites apicais deriva de um correto diagnóstico, o qual se encontra na dependência do conhecimento da natureza e complexidade das infecções endodônticas. Inúmeras pesquisas delinearam o tipo de microbiota presente em condição de periodontite apical crônica nos dentes completamente formados. Todavia nenhum estudo investigou os tipos de microorganismos presentes em canais radiculares de dentes jovens portadores de periodontite apical crônica, onde diferenças anatômicas, histológicas e morfofuncionais poderiam afetar as características do processo infeccioso. O presente estudo tem por objetivo delinear a característica microbiológica de canais radiculares de dentes permanentes jovens portadores de infecção primária. Foram selecionados 12 pacientes com necessidade de tratamento endodôntico em um ou mais dentes unirradiculares, portadores de rizogênese incompleta, diagnóstico clínico de necrose pulpar, em decorrência de injúria traumática, e condição de infecção endodôntica primária. Após o acesso, dezenove espécimes microbiológicos foram obtidos do interior dos canais radiculares com auxílio de cones de papel, os quais foram transferidos, imediatamente, para frascos contendo 2 mL de meio de transporte pré-reduzido VMGA III. As amostras foram diluídas e semeadas em placas do tipo Petri contendo meios de cultura seletivos para detecção de espécies de enterococos, de espécies de leveduras e para crescimento de bactérias totais. As placas semeadas foram incubadas em tempo e temperatura adequados ao crescimento dos microorganismos alvo. Ao final do período de incubação foi realizada uma análise quantitativa do crescimento microbiano presente segundo a contagem das unidades formadoras de colônias. Microorganismos anaeróbios foram recuperados de todos os canais e o número médio de células por canal foi de 5,7 x 106. Quatro amostras (21,05%) evidenciaram o crescimento de Bacteroides produtores de pigmento negro e número médio de células por canal foi de 6,5 x 105. Um espécime (5,25%) exibiu o crescimento de espécies de enterococos e o número médio de células neste canal foi de 1,5 x 104. / Normally cement and enamel act as protective barrier to the dentin and the pulp. However, mechanical, chemical and microbial factors should destroy this protection and display the dentin and, even the pulp, to the oral environment, making possible their contamination. The pulpo-dentin complex reacts in different forms at the presence of microorganisms. However, when irreversible inflammatory alterations are succeeded, they occasion a tecidual clutter on periradicular region. The therapy of periradicular pathosis results from a correct diagnostic, which depends on the knowledge of the nature and complexity of endodontic infections. Several studies have been conducted to disclose microorganisms in the root canal system and/or to investigate the structure of the root canal microbiota in chronic periodontits in teeth completely formed. However there is no information on the microbiology of primary endodontic infection in young teeth where anatomic, histologic and morfologic differences could affect the characteristics of the infectious process. The aim of the current study was to investigate the microbiological status of the root canals from permanent young teeth with primary endodontic infection. Twelve patients with the need for endodontic treatment participated in the study. The selected teeth (one or more tooth per patient) were uniradicular, containing a single root canal and an incomplete root formation, their pulp chamber was without visual communication with the oral fluid, they presented with untreated necrotic pulp, and showed radiographic evidence of periapical periodontits. After the access, nineteen microbiological samples were obtained from the root canals with sterile paper points. Afterwards, the paper points were pooled in a sterile tube containing 2mL of pre-reduced transport fluid (VMGA III). The samples were diluted and spread onto plates with selective medium for enterococcus (agar m-Enterococcus) and for yeast species (agar Sabouraud-dextrose) and onto plates with nonselective medium (agar Brucellasangue). A quantitative analysis was performed. The mean number of cultivable bacterial cells in the root canals was 5,7 x 106. In four samples (21.05%) Black Pigmented Bacteroides species were recovered and the mean number of cells was 6,5 x 105. One specimen (5.25%) showed the growth of enterococos species and the mean number of cells in this case was of 1,5 x 104.
87

Avaliação in vitro da microtração de sistemas adesivos à dentina irrigada com soluções endodônticas: Influência da degradação da interface adesiva / In vitro evaluation of systems on microtensile bond strength to orrogated dentin with endodontic solutions. Adhesive interface degradation influence

Galafassi, Daniel 27 January 2009 (has links)
O objetivo desse trabalho foi avaliar a influência da resistência de união de sistemas adesivos à dentina irrigada com substâncias endondônticas, após a degradação da interface adesiva e análise morfológica da interface adesiva por meio de microscopia eletrônica de varredura (MEV). Foram selecionados sessenta terceiros molares, que tiveram a porção oclusal removida e planificada expondo a dentina profunda. Os espécimes foram irrigados com hipoclorito de sódio a 2,5% por 30 minutos e em seguida em EDTA 17% por 5 minutos. Após a irrigação da superfície detinária os dentes foram divididos aleatoriamente em seis grupos (n = 10) de acordo com o sistema adesivo empregado: G1 e G2 - Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). Após a aplicação do sistema adesivo, foi confeccionado um platô de resina composta Z100 (3M). A degradação da interface adesiva foi realizada por meio de estocagem em água deionizada/ciclagem térmica: 24 horas de estocagem em água deionizada/nenhum ciclo (grupos G1, G3 e G5) e 6 meses de estocagem em água deionizada/12.000 ciclos (grupos G2, G4 e G6). Após os períodos pré-estabelecidos em cada grupo, os conjuntos dente/resina foram seccionados de forma a se obter 4 palitos de aproximadamente de 1mm2, que foram submetidos ao teste de microtração. A análise morfológica da interface foi realizada por meio de MEV. Os dados obtidos foram submetidos a ANOVA e teste de Tukey ao nível de 5%. Verificou-se que houve diferença significativa entre os adesivos (p<0,01). A durabilidade da adesão da resina composta a dentina irrigada com solução endodôntica não foi afetada após 6 meses de estocagem em água e 12.000 ciclos térmicos (p<0,05). A análise da interface adesiva evidenciou que os sistemas adesivos não alteraram o padrão de união mesmo após 6 meses de ciclagem térmica e degradação em água, exceto para o sistema adesivo XP Bond. Pode-se concluir que a dentina irrigada com NaOCl e EDTA apresentou menor resistência a microtração quando do emprego do sistema adesivo XP Bond. A degradação da interface por meio do armazenamento em água e ciclagem térmica não influenciou na resistência de união, independente do sistema adesivo empregado. / The aim of the present study was to survey the influence of endodontic irrigants on the adhesion resistance of adhesive systems to human dentin, after the degradation of adhesive interface and morphologic analysis of adhesive interface for Scanning Electronic Microscopy SEM. Sixty molar thirds were selected. The deep dentin was exposed removing and ground the oclusal portion. The specimens were irrigated with sodium hypochlorite 2,5% for 30 minutes followed by EDTA 17% for 5 minutes. Subsequently, teeth were divided randomly in six groups (n=10) accordingly to adhesive system applied: G1 and G2 Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). After adhesive system application, a composite resin Z100 (3M) was built up created. The degradation of the adhesive interface was realized by storage the specimens in deionized water and thermocycling: 24 hours of deionized water storage/no cycle (groups G1, G3 and G5) and 6 months storage in deionized water/12.000 cycles (groups G2, G4 and G6). After pre-established periods of each group, the systems tooth/resin were sectioned in order to obtain 4 sticks of approximately 1mm2, which were subjected to microtensile bond strength test. The morphologic analysis of interface was performed for SEM. Results were analyzed with ANOVA and Tukey test to level 5%. Significant difference between adhesives was verified (p<0,01). The water storage (6 months) coupled with thermocycling (12.000 cycles) did not affected significantly the resistance to microtensile bond strength of the dentin (p<0,05). The conclusion is that dentin irrigated with NaOCl and EDTA presented less resistance to microtensile bond strength when XP Bond Adhesive system was utilized. The interface degradation through water storage and thermocycling had no effect on the resistance of the dentin bond, independently of the adhesive system applied.
88

\"Resistência à perda de corte de instrumentos rotatórios de níquel-titânio submetidos à implantação iônica de nitrogênio\" / utting ability resistance in nickel-titanium instruments submitted to nitrogen ion implantation

Costa, Cristiane da 05 December 2006 (has links)
O presente estudo verificou o aumento da resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio, após tratamento de implantação iônica de nitrogênio. Para tal, foram utilizados vinte e um instrumentos da marca K3 ?ENDO, de n° 25.02, com 21 mm, divididos em dois grupos. O grupo 1 foi constituído por onze instrumentos submetidos à ação de uma câmara de implantação iônica de nitrogênio, servindo um deles como controle para a determinação da quantidade de íons implantados. O grupo 2 foi composto por dez instrumentos não submetidos ao processo de implantação iônica. Cada lima instrumentou 20 blocos de canais simulados 20.02 de 21 mm, previamente lavados em cuba ultra-sônica com detergente a 40°C por 10 minutos e depois com água bidestilada por mais 10 minutos. Os mesmos foram secos com jato de ar, voltaram para estufa a 40°C por 2 dias e finalmente pesados em balança analítica. Após cada instrumentação os blocos foram lavados em cuba ultra-sônica com detergente a 40°C por 20 minutos e pesados novamente. O ensaio de resistência à perda de corte foi realizado mediante a instrumentação de cada bloco com auxílio de um simulador de ação da instrumentação endodôntica, sendo a amplitude percorrida pelo contra-ângulo padronizada em 2,5 mm a cada penetração por 8 vezes atingindo um total de 2,0 cm para dentro do canal simulado, com força de penetração de 1,5 N. Quanto a resistência à perda de corte os resultados mostraram que os instrumentos implantados não apresentaram diferença estatisticamente significante em nível de 5 % (? = 0,5 %) até 20 usos. Porém, os instrumentos não implantados mostraram diferença estatisticamente significante (? = 0,5 %) entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Ao compararem-se instrumentos implantados e não implantados, observou-se que em 5 e 10 usos não houve diferença estatisticamente significante (p>5%). Já na comparação entre ambos com 15 e 20 usos a diferença foi estatisticamente significante (? = 0,5 %). Lícito foi concluir, portanto, que o processo de implantação de íons de nitrogênio manteve a resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio até 20 usos. Os instrumentos não implantados mostraram perda progressiva do poder de corte significativamente entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Comparando-se instrumentos implantados e não implantados, observou-se que até 10 usos ambos comportaram-se igualmente no que respeita à perda de corte. Já na comparação entre ambos com 15 e 20 usos a diferença foi significativa. / The present study investigated the cutting ability resistance in nickel-titanium instruments after nitrogen ion implantation treatment. Twenty-one instruments of K3 ?ENDO brand, number 20.02, with 21 mm, were divided in two groups. The group 1 submitted 11 instruments to nitrogen ion implantation chamber, while on served as positive control for the determination of the ion implantation quantity. In group 2, the 10 instruments were not submitted to ion implantation treatment. Each file instrumented 20 acrylic blocks 20.02 with 21 mm, previously washed in ultrasonic container with detergent in 40°C for 10 minutes and then with bidestiled water for 10 minutes. They were dried and put in a 40°C stove for 2 days and finally weighed in analytic balance. After instrumentation the blocks were washed for 20 minutes and weighed again. The usage essay was realized through the instrumentation of each block using an endodontic instrumentation simulated action, with a 2,5 mm standardized distance for 8 times, getting a total of 2,0 cm inside the simulated canal with a strong penetration of 1,5 N. The results showed that there was no statistical difference in cutting resistance of instruments treated with ionic implantation process until 20 uses. Although in the non treated instruments there was a gradual reduce in cutting ability resistance from 5 to 20 uses. The conclusion was that the nitrogen ion implantation process increases the cutting resistance of nickel-titanium instruments.
89

Análise da remoção da smear layer e penetração intratubular do cimento obturador após diferentes protocolos de irrigação - estudo em microscopia eletrônica de varredura e confocal a laser / Analysis of smear layer removal and tubular dentine sealer penetration after different irrigation protocols - a study performed by scanning electron and laser confocal microscopy

Machado, Ricardo 23 April 2015 (has links)
O objetivo do presente estudo foi avaliar a remoção da smear layer e a penetração intratubular do cimento obturador AH Plus utilizando diferentes protocolos de irrigação. Após aprovação do Comitê de Ética em Pesquisa da Faculdade de Odontologia de Ribeirão Preto - FORP/USP, noventa incisivos centrais superiores foram selecionados e fornecidos pelo banco de dentes da mesma instituição. Estes foram radiografados no sentido mésio - distal e vestíbulo - lingual para comprovar a presença de canais únicos, sem curvaturas abruptas, reabsorções ou tratamentos endodônticos prévios. Após a remoção da porção coronal para a obtenção de raízes com comprimentos padronizados de 15 milímetros, os diâmetros anatômicos foram determinados e as instrumentações realizadas por meio da técnica coroa ápice estabelecendo os diâmetros cirúrgicos utilizando 3 instrumentos acima dos anatômicos. Durante este processo, os espécimes foram divididos em seis grupos de acordo com os protocolos de irrigação: Grupo 1 (controle - n. 15) - 2,5ml de água destilada a cada troca de instrumentos e 2,5ml de água destilada por 3 minutos ao final da instrumentação; Grupo 2 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de hipoclorito de sódio a 2,5% por 3 minutos ao final da instrumentação; Grupo 3 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 4 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de EDTA a 17% a cada troca de instrumentos + 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 5 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação; Grupo 6 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de ácido cítrico a 10% a cada troca de instrumentos + 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação. Após esta fase, cinco espécimes de cada grupo foram clivados no sentido mésio - distal para avaliação da remoção da smear layer em microscopia eletrônica de varredura por meio da análise de 3 imagens de cada terço em aumentos de 300, 1000 e 2000 vezes. Esta variável foi determinada por um score qualitativo estabelecido pelo consenso de 3 avaliadores calibrados. Os demais espécimes foram obturados pela técnica de condensação lateral com cones principais correspondentes ao último instrumento associados ao cimento AH Plus corado com Rodamina B, cones acessórios B8 e mantidos em ambiente com 100% de umidade por 7 dias. Em seguida, os espécimes foram seccionados transversalmente para obtenção de slices de aproximadamente 2mm de espessura em cada terço (cervical, médio e apical) e as faces cervicais submetidas a um tratamento metalográfico para análise da penetração intratubular do cimento obturador em microscopia confocal a laser. Os melhores índices de remoção de smear layer e as maiores porcentagens de penetração intratubular do cimento foram obtidos pelos grupos onde as soluções quelantes foram utilizadas (G3, G4, G5 e G6) com diferenças estatisticamente significantes (p<0,05) em relação aos grupos onde utilizou - se somente a água destilada (G1) e o hipoclorito de sódio a 2,5% (G2) durante o processo de instrumentação. Não foram observadas vantagens em relação ao uso associado do EDTA a 17% e do ácido cítrico a 10% ao hipoclorito de sódio pela ausência de diferenças estatísticas significantes entre os grupos 3 e 4 e 5 e 6, respectivamente. / The aim of this study was to evaluate the smear layer removal and tubular dentine sealer penetration of AH Plus after different irrigation protocols. After approval of the study by the Ethics Committee of the Ribeirão Preto Dental School - FORP/USP, ninety maxillary central incisors were selected and supplied by the tooth bank of the same institution. The teeth were radiographed in the mesiodistal and buccolingual directions to verify the presence of single canals, without abrupt curvatures, resorption or previous endodontic treatment. The coronal portion was removed and roots lengths were standardized at 15 mm. The anatomic diameters were then determined and instrumentations were carried out by the crown-down technique, using 3 higher-diameter instruments to establish the surgical diameters. During this process, the specimens were divided into six groups, according to the following irrigation protocols: Group 1 (control - n. 15) - 2.5ml of distilled water at each change of instruments + 2.5ml of distilled water for 3 minutes at the end of the instrumentation; Group 2 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5 ml of 2.5% sodium hypochlorite for 3 minutes at the end of the instrumentation; Group 3 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 4 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5ml of 17% EDTA at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 5 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 10% citric acid for 3 minutes at the end of the instrumentation; Group 6 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5 ml of 10% citric acid at each change of instruments + 2.5 ml of 10% citric acid for 3 minutes at the end of the instrumentation. Following this phase, five specimens from each group were cleaved in the mesiodistal direction to evaluate the smear layer removal by scanning electron microscopy. Evaluation was performed by analyzing 3 images of each third at 300, 1000 and 2000X. This variable was determined by a qualitative score established by the consensus of 3 calibrated examiners. The remaining specimens were filled using lateral condensation with AH Plus sealer labeled with Rhodamine B and kept in an environment with 100% humidity for 7 days. Then, the specimens were sectioned to obtain approximately 2 mm thick slices of each third (cervical, middle and apical). The cervical surfaces were subjected to metallographic treatment for analysis of the tubular dentine sealer penetration by confocal laser microscopy. The highest smear layer removal rates and tubular dentine sealer penetration percentages were obtained by the groups that used chelating solutions (G3, G4, G5 and G6). These showed statistically significant differences (p<0.05) compared with the groups that used just distilled water (G1) and 2.5% sodium hypochlorite (G2) during instrumentation. No benefits were observed for the combined use of 17% EDTA or 10% citric acid with 2.5% sodium hypochlorite, considering that there were no statistically significant differences between groups 3 and 4, and between 5 and 6, respectively.
90

Estudo crítico dos métodos moleculares utilizando iniciadores universais na identificação da microbiota endodôntica e da desinfecção do sistema de canais radiculares / Critical study of the molecular methods using universal primers for the identification of endodontic microbiota and disinfection the root canal system

Shin, Regina Célia Furukava 11 September 2012 (has links)
No sentido de colaborar com o estudo da redução de microrganismos em Endodontia, foi realizada uma análise crítica dos modelos metodológicos in vivo sobre as técnicas moleculares utilizadas na avaliação da microbiota endodôntica e na capacidade de medir a antissepsia que o tratamento endodôntico proporciona. Desta maneira, os trabalhos foram agrupados de acordo com a proposta do presente estudo. Na análise critica e comparativa, pode-se observar uma grande variedade de métodos moleculares aplicados nos estudos, sendo que o mais utilizado nos ensaios para avaliação da microbiota foi o PCR. Havia estudos que utilizavam uma combinação de vários métodos onde foi possível identificar microrganismos ainda não conhecidos. Nos ensaios que utilizam iniciadores universais e que se valem da identificação de microrganismos através do DNA, foram listados de maneira a poder observar que o iniciador universal formado pela seguinte cadeia de oligonucleotídeos: F: 5- AGA GTT TGA TCC TGG CTC AG-3/R: 5-ACG GCT ACC TTG TTA CGA CTT-3 foi o mais descrito pela literatura. / In order to collaborate with the study of disinfection in Endodontics, was performed a study of critical methodological models in vivo on the molecular techniques used in the evaluation of endodontic microbiota and the ability to measure the disinfection capacity of endodontic treatment. Thus, the studies were grouped according to the purpose of this study. Under in critical and comparative analysis its can be seen a wide variety of molecular techniques used in the studies, and as used in the tests was to evaluate the microbial PCR studies using a combination of various methods which could be identified microorganisms has not known. In assays using universal primers which rely on the identification of microorganisms using the DNA, were listed as to be able to observe that the universal primer chain formed by the following primers: F: 5\'-AGA GTT TGA TCC TGG CTC AG-3 \'/ R: 5\'-ACG GCT ACC TTG TTA CGA CTT-3\' was as described in the literature.

Page generated in 0.0557 seconds