• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 104
  • 27
  • Tagged with
  • 131
  • 65
  • 60
  • 55
  • 21
  • 19
  • 18
  • 17
  • 15
  • 15
  • 13
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Passivhuset i det långa loppet : - hur påverkar brukarens kunskap energiförbrukningen?

Hedkvist, Karin, von Gegerfelt,, Rebecca January 2012 (has links)
The scope of this investigation is to decide how and to what extent the energy consumption of a passive house is affected by the users’ knowledge and habits. To achieve this a literary study has been made and as a complement the planning of a passive house was completed. The result of a primary study of the rules and regulations that effect passive houses in Sweden shows that the user’s influence on passive houses is a completely unregulated area. Even though there is no regulation, a need for some general knowledge of the passive house concept has been expressed. To further investigate how the users’ knowledge and habits affect the energy consumption and if there is a difference between different households’ energy consumption , three main factors have been identified. The factors are as follows:  Indoor-temperature  Hot water consumption  Consumption of electricity for household appliances After the study of factors that influence unwanted user behaviors, different tools that can help to reduce user-related energy consumption has been investigated. As pointed out earlier a need for some knowledge of the passive house concept has been expressed as, if not necessary, at least very useful to the user in a passive house. That knowledge is transferred between builder- buyer, buyer-seller, landlords -tenants during different stages of a passive house’s life. The following means of communication are used:  Meetings  A user’s guide  Interactive – displays  Knowledgeable technicians What concerns the planning of the passive house, the house did not reach the Swedish passive house requirements, but none the less it was an important tool to gain further insight to factors that can affect the energy consumption in a passive house.
22

Styrning av datorers strömlägen med enhetsigenkänning via trådlösa nätverk : Controlling computer power modes using device recognition via wireless networks

Klintström, Angelica, Badini, André January 2015 (has links)
Rapportens syfte är att påvisa möjligheten att sänka energiförbrukningen på arbetsplatser. I samband med detta arbete utvecklas en hårdvarulösning, som kallas AutoSleep, vars syfte är att automatisera arbetsdatorns byte mellan strömspar- och aktivt läge.AutoSleep utför sin uppgift genom att söka efter en specifik förutbestämd enhet bland de enheter som för stunden är uppkopplade mot arbetsplatsens nätverk. Beroende på om enheten hittas eller ej skickar AutoSleep en signal till datorn som därefter antingen försätter datorn i strömsparläge eller i aktivt läge. För att undersöka nyttan och nödvändigheten hos arbetet utfördes en kvalitativ litteraturstudie, sammanställning av statistik från två enkäter, en intervju och en experimentell studie. All insamlad teori och statistik jämfördes med tidigare studier för att avgöra rapportens tillförlitlighet. Resultatet visade att det finns ett stort utrymme för förbättring inom energieffektiviseringen vid användandet av arbetsdatorer. Det system som utvecklades i samband med arbetet kan på ett enkelt sätt bidra till en energismartare arbetsmiljö. Arbetet visar på en möjlig lösning och använder ett hårdvarugränssnitt som endast är tillgängligt på stationära datorer. Hårdvarulösningen använder en smartphone som verktyg för enhetsigenkänning och växlar endast datorns strömläge mellan strömspar- och aktivt läge.
23

Standarder för att mäta byggnaders lufttäthet / Standards to measure buildings airtightness

Johansson, Emmy, Spahic, Alisa January 2016 (has links)
Svensk Standard ger ständigt ut nya versioner av sina standarder. I rapporten undersöks standarden EN 13829:2000 och den nyare versionen av samma standard, EN 9972:2015. Dessa innehåller båda metoder för bedömning av byggnaders termiska egenskaper, bestämning av byggnaders lufttäthet och tryckmetoder. En jämförelse görs för att se vilka eventuella förändringar den nya versionen kan få för företaget BoKlok och liknande byggföretag i deras arbete med lufttäthet. Provtryckningar har utförts och utifrån resultat från dessa presenteras beräkningsresultat avseende värmeförluster genom transmission, ventilations och luftläckage, vilket syftar till att belysa vilken inverkan lufttäthet har på energiförbrukningen.
24

Utvärdering av jetomrörning : En studie gällande utvärdering av omrörningssystem vid Ekeby reningsverk

Moberg, Emma January 2015 (has links)
Biogas is a renewable energy produced through anaerobic digestion, which means that organic matter is degraded by microorganisms under anaerobic conditions. The produced biogas can then be used for cogeneration, electricity, heat or upgraded to vehicle gas. Eskilstuna Energy & Environment AB has four digesters at Ekeby water sewage treatment plant, Eskilstuna. One of the biogas reactor (RK4) is equipped with a jet-mixing system while the remaining digester uses top-mixing. The mixing system is an important parameter to achieve optimum operating conditions for the process regarding gas production and degree of digestion. This study aims to evaluate the two mixing systems, jet-mixing and top- mixing. The design of the reactors is identical and they are assumed to be fed with the same amount of substrate. By collection, analysis and compiling of process- and operational data such as gas production, degree of digestion and energy consumption for the two different systems their performance has been compared to each other. Different operational conditions considering the energy consumption for the jet-mixing system has been done theoretical to try to reduce the energy consumption. The result shows that both rectors operates under stable process conditions, although the result indicates that the gas production for the reactor installed with jet-mixing system is greater than the system with top-mixing system. Hopefully, the result of the study could be used of Ekeby water sewage treatment plant as an indication of how the system could be run. Keywords: Biogas, mixing, mixing system, anaerobic digestion, gas production, energy consumption, degree of digestion, Ekeby water sewage plant. Nyckelord: Biogas, omrörning, omrörningssystem, anaerob rötning, gasproduktion, energiförbrukning, utrörningsgrad, Ekeby reningsverk.
25

Energiförbrukning och utsläpp av koldioxid vid byggande av väg

Al agedi, Bilal, Ibrahim, Maytham January 2010 (has links)
<p>Markförstärkning i ett vägbygge kan göras på olika sätt. I detta examensarbete jämför vi två av dessa metoder, nämligen massutskiftningsmetoden och användning av kalkcementpelare ur energi- och miljösynpunkt. För att jämföra dessa två metoder togs fram ett excelbaserat räkneverktyg där resultatet av energiförbrukningen fås i kWh och koldioxidemissioner i ton CO<sub>2</sub>. Denna jämförelse gjordes för ett specifikt vägprojekt som använde massutskiftningsmetoden för vägunderbyggnaden. Det som ingick i beräkningen var schaktning, fyllning, krossning, sprängning, transporter och kalkcementpelare. För denna uträkning användes data från både entreprenörer som var med i projektet och företag som hade dokumenterade data.</p><p>Metoden som förbrukade minst energi och som släppte ut minst koldioxidemissioner var massutskiftningsmetoden. Det som gjorde att kalkcementpelare till en sämre metod var den höga energiförbrukningen som krävdes för tillverkningen av kalk och cement. Det som krävde mest energi i tillverkningsprocessen var ugnar där höga temperaturer krävdes.</p><p>Skillnaden mellan utskiftningsmetoden och kalkcementpelare i objektet var att i massutskiftningsmetoden krävdes urgrävningar för att schakta bort jordmaterial med dålig hållfasthet och ersätta det med bergmaterial med hög hållfasthet. I denna metod går energi åt till schaktning, fyllning och transport. Medan förstärkningsmetoden med kalkcementpelare förbrukar energi för tillverkning, transport och installation. Eftersom metoden går ut på att vägbyggnaden ska vila på pelarna genom att borra ner dessa i marken istället för att schakta bort stora volymer och transportera dem till fyllningen så är det lätt att tro att kalkcementpelare sparar energi genom att minska massförflyttning och långa transporter. Resultatet av detta examensarbete har visat motsatsen.</p>
26

Energiförbrukning för putsade, odränerade träregelväggar i fuktigt respektive torrt tillstånd

Arvidsson, Erik January 2009 (has links)
<p>In recent years, moisture damages have been noticed in rendered, undrained stud walls. The design is built on the principle one-stage tightening which means that there is no air gap in the construction. The damages have occurred when water has permeated through the rendering in leaking connections and fittings for windows, doors, canopies, balconies, terraces and awnings. Behind the plaster carrier, which consists of either polystyrene or rigid mineral wool, plasterboard has often been used as a wind protection barrier. In many cases the wind protection barrier and the underlying wooden studs have been exposed to mould and in some cases even rot. It has been shown that damp in the structure is difficult to dry out.</p><p>The aim of the thesis has been to examine how the energy consumption is affected when this type of construction is damp, partly because energy is required to dry up damp, partly because the insulation ability for a material decreases when it is affected by moisture.</p><p>Previous research and relevant literature has been used in this thesis, to provide: A comprehensive picture of the problem, an explanation for the calculations used and an understanding of the conclusions drawn.</p><p>The energy consumption has been calculated for 1 m<sup>2 </sup>wall area on two types of wall designs. The calculations have been performed in both dry and damp condition. To calculate the energy consumption in damp condition, three different types of calculation models have been used in three different ways. Since no measurements have been made, the calculations are to some extent based on assumed values.</p><p>The amount of damp that have entered the structure has, according to the calculation models used, been shown to produce small differences in energy consumption compared to the dry structure. The main problem for these types of walls seems instead to be the growth of microorganisms. Nevertheless, the microorganisms seem not to have affected the indoor environment in any significant manner.</p>
27

Energideklarationer i flerbostadshus i Gävle

Ekbergh, Lina, Forss, Jenny January 2010 (has links)
Syfte: Syftet med uppsatsen är att undersöka hur energideklarationen har tagits emot och påverkat fastighetsägares arbete med energifrågor i flerbostadshus i Gävle. Metod: Denna uppsats baseras på kvalitativa intervjuer med fastighetsägare i Gävle. Fastighetsägarna som har medverkat är från den kommunala och privata hyressektorn samt kooperativa bostadsrättsorganisationer och privata bostadsrättsföreningar. Intervjumaterialet har sammanställts i fem olika kategorier i löpande text med förtydligande tabeller och diagram. Resultat och slutsats: Endast tre av de sju tillfrågade fastighetsägarna är helt färdiga med energideklarationerna. Alla respondenter anser att energideklarationen är bra över lag, men det finns även flera saker som de anser är negativt med energideklarationen. Majoriteten av respondenterna anser att de inte har gjort några större förändringar i och med den nya lagen, de jobbade redan med energibesparande åtgärder innan energideklarationerna genomfördes. Förslag till fortsatt forskning: I uppsatsen har vi inte tagit hänsyn till de boende och deras påverkan av energiförbrukningen. Intressant vore att undersöka hur fastighetsägarna kan påverka deras energiförbrukning och hur medvetna de boende är om sina vanor. Uppsatsens bidrag: Uppsatsen har gett en inblick i hur energideklarationen fungerar i verkligheten och hur den har tagits emot av fastighetsägare i Gävle. Vidare har uppsatsen bidragit till en överblick över vad de olika fastighetsägarna fokuserar på när det gäller energifrågor. Nyckelord: Energideklaration, energiförbrukning / Aim: The aim of this paper is to investigate how the Energy Performance Certificate have been received and have affected building owner’s work with energy related issues in residential buildings in Gävle.   Method: This paper is based on qualitative interviews with building owners in Gävle. The property owners who have contributed are from the municipal and private rental sector, co-operative economic associations and private housing cooperatives. The interview material has been put together in five different categories with clarifying tables and diagrams.   Result and conclusions: Only three out of seven building owners have completed the Energy Performance Certificates (EPC). All respondents generally think that the EPC is good, but there are several things that they consider negative about the EPC. The majority of the respondents think that they have not made any major changes with the new legislation; they already worked with energy-saving measures before the EPC was carried out.   Suggestions for future research: In the paper we have not considered the tenants and their influence on the energy consumption. It would be interesting to research how the building owners can affect their energy consumption and how aware they are of their habits.   Contribution of the thesis: The paper gives an insight in how the EPC works in reality and how it has been received by building owners in Gävle. Furthermore, the paper have contributed to a general view of what the building owners focus on when it comes to energy relates issues.   Key words: Energy Performance Certificate, Energy consumption
28

Energiförbrukning och utsläpp av koldioxid vid byggande av väg

Al agedi, Bilal, Ibrahim, Maytham January 2010 (has links)
Markförstärkning i ett vägbygge kan göras på olika sätt. I detta examensarbete jämför vi två av dessa metoder, nämligen massutskiftningsmetoden och användning av kalkcementpelare ur energi- och miljösynpunkt. För att jämföra dessa två metoder togs fram ett excelbaserat räkneverktyg där resultatet av energiförbrukningen fås i kWh och koldioxidemissioner i ton CO2. Denna jämförelse gjordes för ett specifikt vägprojekt som använde massutskiftningsmetoden för vägunderbyggnaden. Det som ingick i beräkningen var schaktning, fyllning, krossning, sprängning, transporter och kalkcementpelare. För denna uträkning användes data från både entreprenörer som var med i projektet och företag som hade dokumenterade data. Metoden som förbrukade minst energi och som släppte ut minst koldioxidemissioner var massutskiftningsmetoden. Det som gjorde att kalkcementpelare till en sämre metod var den höga energiförbrukningen som krävdes för tillverkningen av kalk och cement. Det som krävde mest energi i tillverkningsprocessen var ugnar där höga temperaturer krävdes. Skillnaden mellan utskiftningsmetoden och kalkcementpelare i objektet var att i massutskiftningsmetoden krävdes urgrävningar för att schakta bort jordmaterial med dålig hållfasthet och ersätta det med bergmaterial med hög hållfasthet. I denna metod går energi åt till schaktning, fyllning och transport. Medan förstärkningsmetoden med kalkcementpelare förbrukar energi för tillverkning, transport och installation. Eftersom metoden går ut på att vägbyggnaden ska vila på pelarna genom att borra ner dessa i marken istället för att schakta bort stora volymer och transportera dem till fyllningen så är det lätt att tro att kalkcementpelare sparar energi genom att minska massförflyttning och långa transporter. Resultatet av detta examensarbete har visat motsatsen.
29

Utveckling av regler för bedömning av Energisparutmaningen / Development of rules for assessment of the Energysavingchallenge

Karlsson, Ida, Kelemit, Malin January 2012 (has links)
Människan påverkar klimatet på ett negativt sätt. Därför har EU satt upp vissa mål som har påverkat Sveriges och kommunernas miljöarbete. För att få tillbaka Växjö på kartan som Europas grönaste stad formades en idé inom föreningen GodaHus att starta en energisparutmaning för Växjös kommun och näringsliv. För att utreda olika synpunkter på tävlingen efterlystes ett examensarbete där olika aktörer som kan vara intressanta för tävlingen intervjuades. Svaren sammanställdes i en sammanhängande text med tillhörande diagram från vilken fyra olika förslag till bedömning formades.
30

Resursanvändning vid snötillverkning : En jämförelse av energi- och vattenförbrukningen vid snötillverkning med olika snökanoner

Eriksson, Emelie January 2015 (has links)
Artificial snow resists wind, water and temperature changes better than natural snow and is increasingly used as a complement when natural snow is not enough. In snowmaking, water and energy resources are needed which are limited by the costs as well as regulations depending on where production takes place. Large quantities of water are often retrieved from lakes and then distributed over a concentrated area which disturb nearby ecosystems. Östersund ski stadium has since 2008 been storing artificial snow during summer in order to put it out early in the season, and offer both amateurs and professionals a training and competition venue from 1 November each year. With scarce resources of snow, the professional races have been possible to carry through, while exercising amateurs have been down prioritized with a delayed opening. The study's main purpose has been to investigate whether a change to another snowmaking model could improve the efficiency of snow production, especially considering that the average temperature in Jämtland is expected to increase, and therefore also increasing the use of resources. The snowmaking machine models studied has been Areco Super Snow and SMI Super Puma, both of which are fan driven snow guns powered with a total output of about 24 kW. The result shows that the snow gun SMI Super Puma can increase the efficiency of snow production, thereby reducing water and energy consumption at the ski stadium. This opens possibilities for more snow to be stored and therefore enable the objective of offering cross country trails early in the season. However, the water and energy consumption in the current state is not assessed to be particularly large in comparison to Östersund municipality's total production of drinking water and energy consumption during the winter months of December to March and the stored snow piles are not considered an environmental problem.

Page generated in 0.1041 seconds