• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 939
  • 12
  • 12
  • 12
  • 11
  • 10
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 958
  • 958
  • 236
  • 227
  • 201
  • 134
  • 126
  • 112
  • 105
  • 86
  • 82
  • 72
  • 70
  • 69
  • 67
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Identificação de vazamento em redes de distribuição de água por meio de algoritmo genético com dados transientes / Leak detection in distribution networks water through genetic algorithm with data transient

Alexandre, Adriano Ricardo Almeida January 2005 (has links)
ALEXANDRE, A. R. A. Identificação de vazamento em redes de distribuição de água por meio de algoritmo genético com dados transientes. 2005. 136 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2005. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-06T19:00:26Z No. of bitstreams: 1 2005_dis_araalexandre.pdf: 829086 bytes, checksum: 52577be588b4bd19fdd4d9d424184f9b (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-19T17:44:21Z (GMT) No. of bitstreams: 1 2005_dis_araalexandre.pdf: 829086 bytes, checksum: 52577be588b4bd19fdd4d9d424184f9b (MD5) / Made available in DSpace on 2016-07-19T17:44:21Z (GMT). No. of bitstreams: 1 2005_dis_araalexandre.pdf: 829086 bytes, checksum: 52577be588b4bd19fdd4d9d424184f9b (MD5) Previous issue date: 2005 / A great present problem in the nets of distribution of water in the World is the presence of index of losses, whose considerable portion elapses of the presence of physical losses, tends as the largest component the leaks. These leaks cause not only operational and financial difficulties, as well as waste of this limited natural resource. It constitutes goal in the modern society the decrease of this it records problem. The present work approaches the theme and it proposes a methodology of study of a detection technique and quantification of leaks in distribution nets by of the modeling of this parameter. The employed method in the solution of the inverse problem is the use of data transients for calibration of the parameter leak through the genetic algorithm. In the analysis of the phenomenon transient, the Method of the Characteristics is used. A net example is used to study the identification of leaks and to evaluate the reliability of the method. Several results were presented and discussed with the application of this method in different situations and compared the results obtained by the genetic algorithm with the previous knowledge of the conditions permanent initials and without the use of this knowledge. / Um grande problema presente nas redes de distribuição de água no Mundo é a presença de índice de perdas, cuja parcela considerável decorre da presença de perdas físicas, tendo como o maior componente os vazamentos. Estes vazamentos ocasionam não só dificuldades operacionais e financeiras, como também desperdício deste recurso natural limitado. Constitui meta na sociedade moderna a diminuição deste grave problema. O presente trabalho aborda o tema e propõe uma metodologia de estudo de uma técnica de detecção e quantificação de vazamentos em redes de distribuição mediante modelagem deste parâmetro. O método empregado na solução do problema inverso é a utilização de dados transientes para calibração do parâmetro vazamento por meio do algoritmo genético. Na análise do fenômeno transiente, é utilizado o Método das Características. Uma rede exemplo é usada para estudar a identificação de vazamentos e avaliar a confiabilidade do método. Vários resultados foram apresentados e discutidos com a aplicação deste método em diferentes situações e comparados os resultados obtidos pelo algoritmo genético com o conhecimento prévio das condições permanentes iniciais e sem o uso deste conhecimento.
292

Estudo comparativo das características físicas e químicas e da qualidade sanitária de dois ambientes lacustres costeiros do município de Paraipaba-CE, nordeste do Brasil (lagoas das Almécegas e Canabrava) / Comparative study of physical and chemical characteristics and health quality of two coastal lacustrine environments in the city of Paraipaba-CE, northeastern Brazil (lagoons of Almécegas and Canabrava)

Lima, Cláudio Ricardo Gomes de 17 December 2004 (has links)
LIMA, C. R. G. Estudo comparativo das características físicas e químicas e da qualidade sanitária de dois ambientes lacustres costeiros do município de Paraipaba-CE, nordeste do Brasil (lagoas das Almécegas e Canabrava). 2004. 110 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2004. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-08T18:00:34Z No. of bitstreams: 1 2004_dis_crglima.pdf: 2119275 bytes, checksum: bdb2906905bc762f72d0c5f37db28dd4 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-25T17:06:53Z (GMT) No. of bitstreams: 1 2004_dis_crglima.pdf: 2119275 bytes, checksum: bdb2906905bc762f72d0c5f37db28dd4 (MD5) / Made available in DSpace on 2016-07-25T17:06:53Z (GMT). No. of bitstreams: 1 2004_dis_crglima.pdf: 2119275 bytes, checksum: bdb2906905bc762f72d0c5f37db28dd4 (MD5) Previous issue date: 2004-12-17 / This study was developed at two coastal lakes in the municipality of Paraipaba (on the western coast of Ceará State), which differ for their location: one located in the urban municipality perimeter (Canabrava Lake), and the other one (Almécegas Lake) located in the rural zone (Pedrinhas District). The main objectives of the study were to establish a comparative profile of the physical, chemical, and biological characteristics of those ecosystems, as well as to evaluate the sanitary qualities of the waters and their bathing conditions according to the environmental legislation, associating them to the different degrees of antropic impacts they are submitted to. Thus, the environmental impacts due to the usage and soil occupation of the respective surroundings have been surveyed, and their influence on the spatial-temporal distribution of the parameters analyzed under the rainy season effect. The sample collections were accomplished from January to June, 2004 at four strategically selected places for each one of the lakes. A set of chemical and physical variables was analyzed in order to establish the limnological and metabolic behavior characterization of those two aquatic environments, according to methodologies from APHA et al. (1989 and 1998), and RODIER (1975). Under the bacteriological point of view, fecal contamination indicators (total coliforms – TC, thermal-tolerant coliforms – TTC, and Escherichia coli – EC) have been analyzed, as well as an estimate of the heterotrophic and aerobic bacterial action (heterotrophic and mesophile bacteria – BHM). The Canabrava and Almécegas Lakes are considered of small and medium size, respectively. Both of them are shallow (varying between 2,0 and 4,0 m deep), and have shown great similarity in relation to most of the analyzed parameters, especially water the temperature, pH, turbidity, transparency, “a” chlorophyll, and phytoplanktonic diversity. The largest instabilities have been observed concerning the DQO, DBO5, and total volatile solids variables, in higher values for the Canabrava Lake, evidencing a remarkable contribution of organic matter coming upon a larger soil occupation in the basin. Such behavior is also reflected on the average content of dissolved oxygen (5 mg/L). From the point of view of macro-nutrients (nitrogen and phosphorus), a certain availability of total phosphorus can be observed in both lakes (0,055 mg/L – Almécegas / 0,062 mg/L – Canabrava), however the low values of ionized ammonia and nitrate (2,07 and 0,511 mg/L for Canabrava, and 1,91 and 0,078 mg/L for Almécegas), seem to act as a limiting factor of the euthrofication advance. Regarding the sanitary quality, the results obtained from the coliform counts, have demonstrated that the Canabrava Lake presents lower sanitary quality in relation to the Almécegas Lake, for being located in the urban municipality perimeter, although in a discontinued way; with total and thermal-tolerant coliform values above those allowed by the effective legislation for class 2 water (CONAMA Resolution No. 20/86). Yet, the Almécegas Lake, came up in accordance with the referred resolution, presenting thermal-tolerant coliform values below 1000 NMP/100mL, and total coliforms below 5000 NMP/1000mL. Regarding bathing conditions, both lakes are classified as proper with their waters considered as of excellent quality for primary contact use, once the thermal-tolerant coliforms and a Escherichia coli values were never up to 250NMP/100mL and 200 NMP/100mL respectivelly (CONAMA Resolution No. 274/00). In a general way, the obtained results verify that the pollution level is closely linked to the type and handling of the activities developed in the influence area, and point to the need of measures in order to preserve the Almécegas Lake, and recover the Canabrava Lake, being considered the irregular usage, and the punctual and diffuse pollution that is beginning to reach the latter lake nowadays. / Este estudo foi desenvolvido em duas lagoas costeiras do município de Paraipaba – CE (litoral oeste do Estado), que se diferenciam pela localização: uma situada no perímetro urbano do município (lagoa Canabrava) e a outra (lagoa das Almécegas) situada na zona rural (localidade de Pedrinhas). Os objetivos gerais do estudo foram estabelecer um perfil comparativo das características físicas químicas e biológicas destes ambientes lacustres bem como avaliar as suas qualidades sanitárias e condições de balneabilidade frente a legislação vigente, associando-as aos diferentes graus de impactos antrópicos a que estão submetidos. Para tanto, foram levantados os impactos devidos às atividades de uso e ocupação do solo dos respectivos entornos, e sua influência na distribuição espaço-temporal dos parâmetros analisados, sob efeito do período chuvoso. As coletas foram realizadas no período de janeiro a junho de 2004 em quatro pontos estrategicamente selecionados para cada uma das lagoas. Foi analisado um conjunto de variáveis físicas e químicas que permitiram a caracterização limnológica e do comportamento metabólico dos ambientes aquáticos, segundo metodologias de APHA et al. (1989 e 1998) e RODIER (1975). Do ponto de vista bacteriológico, foram analisados os indicadores de contaminação fecal (coliformes totais - CT, coliformes termotolerantes - CTT e Escherichia coli - EC) e realizada uma estimativa do contingente bacteriano de ação heterotrófica e aeróbia (bactérias heterotróficas e mesófilas - BHM). As lagoas Canabrava e das Almécegas são consideradas de pequeno e médio porte, respectivamente. Ambas de pequena profundidade (variando entre 2,0 e 4,0 m) apresentam grande similaridade em relação à maioria dos parâmetros analisados, em especial temperatura da água, pH, turbidez, transparência e clorofila “a” e diversidade fitoplanctônica. As maiores flutuações foram observadas no tocante às variáveis DQO, DBO5, sólidos totais voláteis, em valores mais elevados para a lagoa Canabrava, evidenciando maior aporte de matéria orgânica advinda da ocupação do solo na bacia. Tal comportamento se reflete também no teor médio de oxigênio dissolvido (5 mg/L). Do ponto de vista dos macronutrientes (nitrogênio e fósforo), observa-se uma certa disponibilidade de fósforo total em ambas as lagoas (0,055 mg/L – Almécegas / 0,062 mg/L – Canabrava), porém os baixos valores de amônia ionizada e nitrato (2,07 e 0,511 mg/L, respectivamente, para Canabrava e 1,91 e 0,078 mg/L respectivamente, para Almécegas), parecem atuar como fator limitante do avanço da eutrofização. Com relação à qualidade sanitária, os resultados obtidos a partir da colimetria, demonstraram que a lagoa Canabrava, por estar inserida no perímetro urbano do município, apresenta qualidade sanitária inferior à lagoa das Almécegas, ainda que de forma descontínua; com valores de coliformes totais e termotolerantes acima daqueles permitidos pela legislação vigente para água de classe 2 (Resolução CONAMA Nº20/86). Já a lagoa das Almécegas, apresentou-se em conformidade com a referida resolução, apresentando valores de coliformes termotolerantes inferiores a 1000 NMP/100mL e coliformes totais inferiores a 5000 NMP/1000mL. Do ponto de vista da balneabilidade, ambas as lagoas enquadraram-se na categoria própria, com suas águas consideradas excelentes para recreação de contato primário, uma vez que os teores de coliformes termotolerantes e Escherichia coli não ultrapassaram 250NMP/100mL e 200 NMP/100mL (Resolução CONAMA 274/00). De forma geral, os resultados obtidos constatam que o nível de poluição relaciona-se diretamente com o tipo e manejo das atividades desenvolvidas na área de influência e apontam para a necessidade de medidas de proteção da lagoa das Almécegas e de recuperação da lagoa Canabrava, considerando-se os usos irregulares e a poluição pontual e difusa que hoje começa a atingir aquela lagoa.
293

Remoção de nitrito, nitrato e amônia de efluentes de indústrias petrolíferas através de reatores biológicos inoculados com “Aspergillus niger” / Nitrite removal, nitrate and ammonia from oil industry effluents by biological reactors inoculated with "Aspergillus niger"

Freitas Neto, Mário de Alencar January 2005 (has links)
FREITAS NETO, M. A. Remoção de nitrito, nitrato e amônia de efluentes de indústrias petrolíferas através de reatores biológicos inoculados com “Aspergillus niger”. 2005. 92 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2005. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-08T18:36:36Z No. of bitstreams: 1 2005_dis_mafreitasneto.pdf: 845871 bytes, checksum: 3b2dd0932a47a69f308f96fbfcb40ea7 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-25T17:29:30Z (GMT) No. of bitstreams: 1 2005_dis_mafreitasneto.pdf: 845871 bytes, checksum: 3b2dd0932a47a69f308f96fbfcb40ea7 (MD5) / Made available in DSpace on 2016-07-25T17:29:30Z (GMT). No. of bitstreams: 1 2005_dis_mafreitasneto.pdf: 845871 bytes, checksum: 3b2dd0932a47a69f308f96fbfcb40ea7 (MD5) Previous issue date: 2005 / The purpose of this research was to evaluate the removal of nitrogen compounds found in petroleum industry wastewater, by employing a biologic process with fungi. During 156 days, two aerobic biologic reactors with fungi (BRF), with immobilized biomass and continuous up flow were built and operated. Both reactors were made in acrylic and presented identical dimensions height 60 cm, 10 cm diameter and 4,5 L liquid volume. The first reactor (R1) had polyamide bed as support medium and the second one (R2) used polyurethane foam. Initially, the reactors containing the wastewater were inoculated with 2 x 106 spores.mL-1, of Aspergillus niger AN 400. They remained in rest, with no aeration, for 24 h mycelium growth. After this period, the aeration and recirculation of the effluent started and here mointained for one week. The recirculation was then suspended and it was initiated the reactors feeding with wastewater and the parameters monitoring. The research was divided in four phases, with different HRT and different glucose concentrations (except phase I) as primary source of carbon. In phase I, the reactors were operated for 35 days with 8h HRT and with no addition of primary source of carbon. Good nitrite removal efficiencies were observed, with mean values of 82% and 89%, for R1 and R2, respectively. For nitrate, the mean values were 53% for R1 and 55% for R2. In relation to ammonia, the mean values in effluent concentration were: R1, 10,31 mg N-NH3.L-1 and R2, 10,62 mg N-NH3.L-1, which were higher than the affluent values, with a mean value of 7,87 mg N-NH3.L-1. In phase II, the reactors were operated for 59 days with HRT of 8h and 0,5 g/L of glucose were added to the affluent. The mean values of ammonia removal were 57% for R1 and 51% for R2. Nitrite, values were 82% and 84% for R1 and R2 respectively, nitrate 70% for R1 and 80% for R2. In phase III, the HRT was reduced to 4h and the addition of glucose was sustained. In this phase, the reactors were operated for 38 days. The removal values observed for ammonia were 54% for R1 and 57% and R2. In relation to nitrite, these values were 90% and 76% for R1 and R2 respectively and for nitrate the values were 63% and 62% for R1 and R2. In phase IV, reactors were operated for 24 days, with HRT of 4h and addition of 1,0 g.L-1 of glucose to the affluent. The removal values obtained for ammonia were 48% and 53% for R1 and R2, and for nitrate these values were 76% and 79% for R1 and R2. In relation to nitrite, the mean value of the effluent was 0,04 mg N-NO2.L-1 for both reactors, twice the value of the affluent (0,02 mg N-NO2.L-1). In this research, it was observed an alternation between production and removal of ammonia and nitrite however the reactors when operated in phase II and III showed efficient in the removal of nitrite, nitrate and ammonia present in petroleum industry wastewater. / A proposta desta pesquisa foi avaliar a remoção de compostos nitrogenados presentes em águas residuárias de indústrias petrolíferas, empregando processo biológico com fungos. Foram montados e operados durante 156 dias, em escala de laboratório, dois reatores biológicos aeróbios com fungos (RBF), com biomassa imobilizada e fluxo contínuo ascendente. Os dois reatores eram constituídos de acrílico e apresentavam dimensões idênticas com 60 cm de altura, 10 cm de diâmetro e volume útil de 4,5 L, sendo que o primeiro reator (R1) teve como meio suporte manta agulhada de poliamida, e o segundo reator (R2) espuma de poliuretano. Inicialmente, os reatores contendo a água residuária a ser estudada foram inoculados com 2 x 106 esporos/mL, de Aspergillus niger AN 400, e deixados em repouso, sem aeração por 24h para crescimento do micélio. Após esse período iniciou-se a aeração e a recirculação do efluente dos reatores que foi mantida por uma semana. Em seguida a recirculação foi suspensa, iniciou-se a alimentação dos reatores com a água residuária e os parâmetros de interesse passaram a ser monitorados. A pesquisa foi dividida em 4 fases, nas quais foram aplicados diferentes TDH e concentrações variadas de glicose (exceto fase I) como fonte primária de carbono. Na fase I os reatores foram operados durante 35 dias com TDH de 8h, sem adição de fonte primária de carbono. Foi observada, boa eficiência de remoção de nitrito, com valores médios de 82%, e 89%, para R1 e R2, respectivamente. Para Nitrato as remoções foram de 53% para o R1 e de 55% para o R2. Com relação à amônia, os valores médios das concentrações nos efluentes, foram: R1 igual a 10,31mgN-NH3 /L, e R2 igual a 10,62 mgN-NH3 /L, as quais foram superiores aos de entrada, com valor médio de 7,87 mgN-NH3 /L. Na fase II os reatores foram operados durante 59 dias com TDH de 8h, com adição de 0,5g de glicose/L ao afluente. Os valores médios de remoção de amônia foram iguais a 57% e 51% para R1 e R2 respectivamente, de nitrito foram 82% para R1 e 84% para R2, e para nitrato os valores de remoção foram de 70% para R1 e 80% para R2. Na fase III o TDH foi reduzido para 4h, manteve-se a adição de 0,5g de glicose/L, ao afluente, sendo que os reatores operaram durante 38 dias. Foram observados valores de remoção de amônia de 54%, e 57% para R1 e R2, respectivamente e para nitrito, estes valores foram de 90%, e 76% para R1 e R2 e para nitrato os valores foram de 63% e 62% para R1 e R2. Na fase IV os reatores foram operados durante 24 dias, com TDH de 4h e adição de 1,0g de glicose/L ao afluente. A remoção de amônia foi de 48% e 53% para R1 e R2, nitrato 76% e 79% para R1 e R2. Em relação ao nitrito, o valor médio no efluente foi de 0,04 mgN-NO2 /L para os dois reatores, sendo o dobro do valor do afluente 0,02 mgN-NO2 /L. Nesta pesquisa os reatores R1 e R2, quando operados nas fases II e III, mostraram-se eficientes na remoção de nitrito, nitrato e amônia de efluentes de indústrias petrolíferas.
294

Análise da dinâmica hidrossedimentológica da bacia hidrográfica do Rio Preto (SC) com o modelo SWAT

Lino, João Félix de Luca January 2009 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Ambiental / Made available in DSpace on 2012-10-24T11:51:50Z (GMT). No. of bitstreams: 1 267130.pdf: 6983632 bytes, checksum: edc9aa683f6afb744717ff2bd14d47e2 (MD5) / O objetivo deste estudo foi analisar a dinâmica hidrossedimentológica da bacia hidrográfica do Rio Preto (1000,41 km²), localizada no planalto norte de Santa Catarina, utilizando o modelo SWAT. Foram aplicadas as calibrações manual e automática para possibilitar as simulações do escoamento superficial e da produção de sedimentos nos diferentes cenários de uso do solo adotados. Para avaliar o desempenho do modelo, os dados diários de vazão simulados pelo modelo SWAT foram comparados com os dados observados na bacia hidrográfica do Rio Preto utilizando o coeficiente de Nash e Sutcliffe e o desvio dos dados simulados em relação aos dados observados. Neste estudo foram escolhidos cinco cenários de uso e cobertura do solo para a bacia. Os cenários têm por objetivo verificar a mudança de uso e cobertura do solo bem como da operação dos reservatórios na dinâmica hidrossedimentológica, verificada pelos hidrogramas e sedimentogramas. Os cenários simulados foram: a) Uso e cobertura atual; b) Mata Nativa; c) Agricultura; d) Reflorestamento; e e) Uso e cobertura Atual sem Reservatórios. Os resultados dos diferentes cenários foram comparados entre si. Observou-se que o cenário 3 (Agricultura) apresentou maior escoamento superficial e produção de sedimentos. O maior impacto na redução do escoamento superficial e da produção de sedimentos foi obtido pela substituição do uso e cobertura atual do solo (cenário 1) pela mata nativa (cenário 2). A maior diferença encontrada entre os cenários nas simulações de escoamento superficial anual foi de 118,17 mm (variação de 57%) entre os cenários 3 (Agricultura) e 2 (Mata nativa) no ano de 1996. Para a produção de sedimento anual, a maior diferença encontrada foi 36,28 ton.ha-1 (variação de 30.230%), entre os cenários 3 (Agricultura) e 2 (Mata Nativa) também para o mesmo ano.
295

Gerenciamento de resíduos sólidos de serviços de saúde no hospital universitários da UFSC: monitoramento e proposição de indicadores de qualidade dos serviços

Ferber, Mercedes Caroline Sales January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:03:41Z (GMT). No. of bitstreams: 1 326840.pdf: 26110844 bytes, checksum: acd44827b0533144e7c195ab2b9fb0cd (MD5) Previous issue date: 2014 / Este trabalho tem por objetivo o monitoramento da geração de resíduos de serviços de saúde e o desenvolvimento de uma ferramenta de avaliação de planos de gerenciamento de resíduos de serviços de saúde através de um conjunto de indicadores de desempenho, tomando por base o Hospital Universitário da UFSC (HU). O trabalho iniciou com monitoramento da geração de resíduos no HU com pesagem diária, que teve duração de um ano (365 dias consecutivos). Paralelo à isto fez-se levantamento bibliográfico buscando levantar e criar indicadores relevantes ao processo de gerenciamento de RSS, os quais foram submetidos ao julgamento de especialistas e aplicados em estudo de caso no HU. O objetivo geral desta pesquisa foi alcançado, uma vez que a metodologia desenvolvida possibilitou monitorar a geração de resíduos de serviços de saúde no HU, bem como, conhecer e quantificar os diferentes tipos de resíduos gerados no estabelecimento. Ademais, a planilha de indicadores proposta incorpora os parâmetros legais e reflete o desempenho ambiental do estabelecimento de saúde. Sua utilização evidenciou as questões mais críticas do sistema de gerenciamento dos RSS no HU, permitindo direcionar estrategicamente as ações de melhoria. A segregação dos indicadores em categorias permitiu organizar as informações partindo de questões amplas às específicas, contemplando todas as etapas do sistema. A planilha pode ser aplicada em qualquer estabelecimento gerador de RSS, e permite comparar diferentes estabelecimentos de saúde.<br> / Abstract : This research aims to monitor the generation of waste of health services (WHS) and the development of a tool for evaluating plans for waste management of health services through a set of performance indicators services, based on the University Hospital of the UFSC (HU). The study started with monitoring of waste generation at HU with daily weighing with duration of one year (365 consecutive days). During that time is also conducted literature survey, intending to find and create new performance indicators relevant to waste management programs, which were submitted to the judgment of experts and applied on a case study at HU. The main objective of this research was achieved once the methodology developed allowed to monitor the generation of wastes from healthcare services in HU as well, know and quantify the different types of waste generated in the setting. In addition, the proposed indicators worksheet incorporates the parameters of the law and reflects the environmental performance of the health facility. Using of the tool revealed the most critical issue of the waste management program in UH, allowing taking strategic actions to improve the whole system. Segregation of indicators into categories allowed organize information starting from broad to specific questions, covering all stages of waste management. The spreadsheet can be applied to any establishment that generates WHS, and allows the comparison of different health facilities.
296

Avaliação de lagoas de Lemnas (Landoltia punctata) para o polimento de esgoto sanitário e fixação de gás carbônico

Brugnago, Natália January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:12:58Z (GMT). No. of bitstreams: 1 329731.pdf: 2706464 bytes, checksum: 4e1fa76a216a2dba37d9ebf66315c5cf (MD5) Previous issue date: 2014 / A fim de mitigar o problema da poluição das águas, as lagoas de lemnas têm sido consideradas como uma tecnologia eficiente e de baixo custo, sendo então aplicadas para o tratamento de esgoto sanitário e agroindustrial. A elevada eficiência na remoção de nutrientes (N e P) é uma das principais vantagens dessa tecnologia. Além disso, a biomassa produzida durante o tratamento pode apresentar um alto valor nutricional, agregando valor ao processo. Desse modo, o presente estudo teve como objetivo avaliar o potencial de um sistema de lagoas de lemnas (Landoltia punctata) no tratamento de esgoto doméstico e fixação de gás carbônico. Com esse intuito, foi realizado um experimento, em escala piloto, constituído por uma lagoa anaeróbia seguida por duas lagoas de lemnas, operando em fluxo contínuo. O sistema recebeu cargas de esgoto doméstico condominial a uma vazão de 200L/d. A avaliação da eficiência do sistema se deu através de análises de amostras do efluente, coletadas em cada etapa do tratamento. Também foram realizadas avaliações qualitativas (teores de proteína e amido) e quantitativas (cargas de crescimento) sobre a biomassa produzida. A fixação de gás carbônico foi avaliada através da medição da concentração, por meio de uma câmara de fluxo, para avaliar o potencial do sistema como redutor de gases do efeito estufa (GEE). No período experimental, o sistema apresentou excelentes resultados na remoção dos parâmetros avaliados, alcançando as seguintes eficiências: DQO= 92%, DBO= 97%, PT= 80%, PO43-= 70%, NTK=85,4%, N-NH3= 87%, Turbidez= 97%, E. coli= 3 log10. Quanto à biomassa de lemnas, foi constatada uma produtividade de até 7,48 g/m²/d, ou 27,3 t/ha/ano, com um teor de proteína médio de 35% e de amido de 4,7%. Foram removidos 9,29kg de CO2, ou 17,4 t CO2/ha/ano, sendo encontrada uma carga de fixação de CO2 de 10,95 g/m²/d. Desse modo, conclui-se que o sistema de tratamento por lagoas de lemnas apresentado no presente estudo possui grande potencial no polimento do esgoto doméstico, além de produzir uma biomassa com valor agregado, passível de valorização. Devido ao seu potencial de fixação de gás carbônico, as lemnas podem neutralizar as emissões de GEE na ETE, enquadrando-se como um mecanismo de desenvolvimento limpo.<br> / Abstract : In order to mitigate the problem of water pollution, the duckweed ponds have been considered as an efficient and low cost technology being applied to the treatment of domestic sewage and agricultural waste. The high removal efficiency of nutrients (N and P) is one of the main advantages of this technology. Also, the biomass produced during treatment can have a high nutritional value by adding value to the process. Thus, the present study aimed to evaluate the potential of duckweed ponds system (Landoltia punctata) in wastewater treatment and carbon dioxide fixation. With this aim, an experiment was conducted on a pilot scale, consisting of an anaerobic pond followed by two duckweed ponds, operating in continuous flow. The system received loads of condominium domestic sewage at a rate of 200 L/d. The evaluation of the efficiency of the system was made through analyzes of effluent samples collected at each stage of treatment. Qualitative assessments (protein and starch content) and quantitative (growth rates) on biomass production were also performed. The fixation of carbon dioxide was evaluated by measuring the concentration, through a flow chamber, to assess the potential of the system as a reduction of Greenhouse Gases. In the trial period, the system showed excellent results in the removal of the evaluated parameters, achieving the following efficiencies: COD = 92%, BOD = 97%, TP = 80%, PO43-= 70%, TKN = 85,4%, NH3-N = 87%, Turbidity = 97%, E. coli = 3 log10. As for the duckweed biomass, we observed a productivity of up to 7.48 g/m²/d, or 27.3 ton/ha/year, with a medium protein content of 35% and 4.7% of starch. Were removed 9.29kg of CO2, or 17.4 tonCO2/ha/year, the rate of CO2 fixation of 10.95 g/m²/day was found. Thus, it is concluded that this treatment systems consisting of duckweed ponds have great potential in polishing of wastewater, and produce a biomass value, subject to valuation. Due to its potential for fixation of carbon dioxide, the duckweed can neutralize greenhouse gas emissions on ETE positioning themselves as a clean development mechanism.
297

Influência da técnica de limpeza de filtros lentos e diâmetro dos grãos sobre a qualidade da água produzida, com destaque para remoção de carbamatos e oocistos de Cryptosporidium (simulados por microesferas)

Pizzolatti, Bruno Segalla January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:27:41Z (GMT). No. of bitstreams: 1 331124.pdf: 14405855 bytes, checksum: f77c07e4675734e6ca2daa670f9a9367 (MD5) Previous issue date: 2014 / Neste trabalho, buscou-se avaliar a tecnologia da filtração lenta retrolavável no tratamento de água de lago com vistas a suprir as necessidades de consumo humano. Foram propostas duas formas de retrolavagem, utilizando a água filtrada ou bruta, sempre, comparadas a um filtro controle com limpeza por raspagem. O objetivo da pesquisa foi avaliar a eficiência dos filtros no tocante a parâmetros físicos, químicos (com destaque para carbamatos: metomil, carbofurano e carbaril) e biológicos (simulados por microesferas fluorescentes), bem como avaliar a eficiência da retrolavagem em filtros lentos. Foram construídos dois sistemas de filtração, sendo um em escala real e outro em escala piloto. Todas as unidades de filtração eram de escoamento descendente, operaram com taxa de filtração de 4 m3/m2 dia e carga hidráulica variável. Durante o monitoramento dos filtros em escala real, foi possível realizar 18 de filtração válidas, em que não se observou diferença significativa de duração entre os filtros controle (FLC) e os filtros retrolaváveis com água filtrada (FLR) e com água bruta (FLRb). Com relação aos parâmetros de qualidade de água cor e turbidez, o FLC teve melhor desempenho que os demais filtros no tocante cor aparente e verdadeira e com relação a remoção de cianobactérias o filtro FLR obteve melhor desempenho. Nos filtros em escala piloto, nos quais foram avaliados os contaminantes específicos (microesferas e carbamatos), formaram um total de seis filtros, agrupados dois a dois (filtros lentos convencionais/retrolaváveis), em que cada grupo de filtros tinha diâmetro efetivo do material filtrante distintos. A granulometria do material filtrante não pareceu interferir na qualidade da água, no entanto o método de limpeza mostrou que os filtros com limpeza por raspagem foram mais efetivos que seus pares retrolaváveis na maior parte dos parâmetros analisados. Para os carbamatos estudados, observou-se remoção máxima de 19,30, 36,94 e 63,80% para o metomil, carbofurano e carbaril respectivamente, não sendo observada também diferença significativa entre os filtros avaliados. Para as microesferas, todos os filtros alcançaram eficiência de 4,75 Log, depois de 8 horas de filtração. Em função dos resultados obtidos, pode-se considerar que o trabalho contribui para facilitar a operação de filtros lentos, com adoção da retrolavagem, o que pode resultar no aumento do uso desta tecnologia principalmente em comunidades isoladas, desprovidas de tratamento e abastecimento público de água.<br> / Abstract: This study aimed to evaluate the backwash slow sand filtration technology in treatment of lake water in order to solve the needs of human consumption. Two forms of backwash were proposed, using filtered and raw water, always compared with a control filter cleaned by scraping. The research objective was to evaluate the efficiency of filtersin relation to physical, chemical parameters (specially carbamates: methomyl, carbofuran and carbaryl) and biological (simulated by fluorescent microspheres), as well as the efficiency of backwash in slow sand filters. Two pilot systems were built a real scale and other smallscale. All filter units are downflow, operated with filtration rate of 4m3/m2dia and hydraulic head variable. During monitoring of full-scale filters, was possible to carry 18 filtration run where no significant difference was observed in duration between the filter control (FLC) and backwashed filter with filtered water (FLC) and raw water (FLRb). Regarding water quality parameters color and turbidity the FLC performed better than other filters regarding apparent and true color, with respect to the removal of cyanobacteria FLR filter performed better than others filters. In small-scale filters which were evaluated specific contaminants (microspheres and carbamates) are a total of six filters, grouped two by two, forming three sets of conventional / backwash slow sand filter where each filter group had distinct effective diameter. The diameter of the filter material did not appear to affect the quality of water however, but scraping method of cleaning was more effective than their backwashed pairs, in most parameters. For carbamates studied the maximum removal of 19,30, 36, 94 and 63,80% for methomyl, carbaryl and carbofuran, respectively, there was no significant difference between the evaluated filters. For all filters microspheres efficiency reached 4,75 log after eight hours of filtration. Depending on the results obtained, it can be considered that the work helps to facilitate the operation of slow sand filters, with adoption of backwash in slow sand filters, and could result in an increased use of this technology especially in isolated communities, which have no treatment and supply of drinking water.
298

Análise ambiental e econômica de cenários de logística reversa de compressores de ar por meio da avaliação de ciclo de vida

Santana, Vanessa Mesquita January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T21:02:24Z (GMT). No. of bitstreams: 1 330187.pdf: 3253322 bytes, checksum: 989ff1edbe517590e588a47a4a5169ff (MD5) Previous issue date: 2014 / A lógica do atual sistema de produção está baseada na fabricação massiva de bens de consumo. Quando esta produção não é realizada de forma coerente e respeitosa aos recursos naturais, ocorre uma excessiva extração de matéria prima, um elevado consumo de energia elétrica, geração de resíduos sem destinação final apropriada, efluentes e emissões atmosféricas sem tratamento final efetivos, entre outros. Visando identificar os danos ambientais relativos à logística reversa de compressores de ar a fim de minimizá-los, esta dissertação objetivou: realizar a Avaliação do Ciclo de Vida (ACV) e Avaliação Econômica do Ciclo de vida (AECV) de cenários de logística reversa de compressores de ar. A metodologia foi baseada nas normas ABNT (2009a; 2009b), em que os dados primários foram obtidos por meio de consultas, entrevistas e telefonemas aos assistentes técnicos, colaboradores e relatórios de venda da empresa Schulz S.A., onde o estudo foi desenvolvido. Foram avaliados quatro cenários de logística reversa: o primeiro baseado em um plano de troca de compressores com desmanche total do compressor e revenda de materiais recicláveis. O segundo também baseado em um plano de troca, porém com refundição de peças de ferro fundido e aço na própria empresa. O terceiro baseado na remanufatura de compressores realizada por assistentes técnicos e compra de 38% do valor financeiro das peças de remanufatura da empresa. O quarto, semelhante ao terceiro cenário, porém com 51% do valor financeiro das peças de remanufatura compradas da empresa. O cenário menos impactante ambientalmente foi o de parceria com assistentes técnicos e compra de 38% das peças originais. Por sua vez o cenário que obteve melhor resultado econômico foi o cenário de plano de troca de compressores com desmanche total do compressor e revenda de materiais recicláveis. No entanto, o cenário de parceria com assistentes técnicos e compra de 51% das peças originais, foi o mais economicamente interessante para a empresa. Como principal resultado desse estudo, foi identificado que o cenário mais ecoeficiente foi o baseado no plano de troca e com refundição de peças de ferro fundido e aço na própria empresa. / Abstract : The logic of the current production system is based on the mass production of consumer goods. When this production is not carried out consistently and respectfully to natural resources, there is an excessive extraction of raw materials, high energy consumption, waste generation without proper disposal, effluents and emissions without effective final treatment, among others. To identify the environmental damage relating to reverse logistics of air in order to minimize them, this thesis aimed to: perform the Life Cycle Assessment (LCA) and Life Cycle Cost (LCC) scenarios for reverse logistics air compressors. The methodology was based on ABNT (2009a, 2009b) standards, in which the primary data were obtained through consultations, interviews and phone calls to the technical assistant, employees and Schulz SA's sales reports, where the study was conducted. Four scenarios for reverse logistics were examined: the first based on a plan of exchanging compressors with a total dismantling of the compressor and resale of the recyclable materials. The second also based on an exchange plan, but with the remelting of pieces of cast iron and steel in the company. The third based on the remanufacturing of compressors performed by the technical assistants and sale of 38 % of the company's remanufacture parts. The fourth scenario, similar to the third one, however, with sale of 51% of the company's remanufacture parts. The scenario that had the least impact on the environment was the one with partnership of the technical assistants, and purchase of 38 % of the original parts. In turn, the most economic scenario was the one with the exchanging compressors, with a total dismantling of the compressor and resale of recyclable materials. However, the most economic scenario for the company was the one in partnership with the technical assistants, and purchase of 51 % of the original parts. The main result of this study identified that the more eco-efficient scenario was the one based on the exchange and remelting pieces of cast iron and steel in the company.
299

Uso e ocupação do solo da área de proteção ambiental do entorno costeiro do Parque Estadual da Serra do Tabuleiro

Machado, Marina de Medeiros January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T21:16:58Z (GMT). No. of bitstreams: 1 328094.pdf: 7046237 bytes, checksum: abf953a6c47771316e801aa8a3e4aa71 (MD5) Previous issue date: 2014 / A implantação de parques nacionais continua a desafiar instituições, técnicos e os atores envolvidos no processo de gestão e proteção dos recursos naturais, tendo em vista os inúmeros conflitos gerados e vivenciados pela população local atingida. A abrangência de nove municípios nos limites do Parque Estadual da Serra do Tabuleiro (PAEST) aliada ao desenvolvimento das cidades, fez com que ele apresentasse uma série de conflitos de interesses e fundiários. Tal situação o forçou a enfrentar, no ano de 2009, uma nova demarcação, objetivando a retirada de áreas de conflitos e criação de novas categorias de Unidades de Conservação. Partindo desse contexto, o presente trabalho visa relatar o histórico do PAEST; discutir o novo zoneamento proposto; debater a respeito das diferenças dos novos limites impostos frente aos limites municipais; avaliar as não conformidades observadas na região nordeste do PAEST; e levantar as características ambientais e de uso e ocupação do solo das terras pertencentes a Área de Proteção Ambiental do Entorno Costeiro do Parque Estadual da Serra do Tabuleiro, na porção nordeste da Baixada do Massiambu, nas praias da Pinheira e Guarda do Embaú, no município de Palhoça/SC. Para o desenvolvimento do trabalho foram realizadas revisões da literatura e levantamentos de campo referentes às restrições ambientais, tendo como aporte a utilização de Sistemas de Informações Geográficas (SIG). Como resultado, obteve-se o levantamento de 6.501 lotes nas praias da Pinheira e Guarda do Embaú, sendo que destes 77% não apresentaram restrições ambientais, 13% apresentaram restrições parciais e 10% restrições totais. Desta forma, percebeu-se que com a redelimitação do PAEST algumas áreas desanexadas possuíam grande relevância ecológica e restrições ambientais impeditivas ao assentamento humano, e deveriam ser mantidas preservadas. O trabalho contribui, portanto, para o entendimento da problemática da região da Baixada do Massiambu, principalmente referente ao uso do solo, de modo que, através de um planejamento ambiental que vise discutir mecanismos de reordenamento do território, possam ser formuladas medidas de proteção e recuperação ambiental desta região.<br> / Abstract : The creation of National Parks continues to challenge institutions, technicians and actors involved in the management and protection of natural resources process, due to the numerous conflicts generated and experienced by the affected local population. The breadth of nine municipalities in the Serra do Tabuleiro State Park (PAEST) within the limits of the Park coupled with the development of cities, making the Park presets a number of interest and land conflicts. This situation forced him to face, in 2009, a new demarcation, aiming the removal of areas of conflict and creation of new categories of protected areas. Considering this context, this work aims to report the PAEST history, to collected environmental characteristics and use and occupation of land owned by the Environmental Protection Area of Surrounding Coastal of the Serra do Tabuleiro State Park, in the northeastern portion of the Baixada Massiambu, the locations of the Pinheira and Guarda do Embaú beaches, in city of Palhoça / SC. For the development of the work, literature reviews about the area of study and field surveys relating to environmental constraints were perfomed, taking as input the use of Geographic Information Systems (GIS). As a result of using this methodology, we obtained the survey of 6,501 plots of land on the Pinheira and Guarda do Embaú beaches, and of these 77% had no environmental restrictions, 13% had partial restrictions and 10% total restrictions. Thus, it was realized that, with the delimitation of the PAEST, some disannexed areas had some great ecological significance for human settlement and hindering environmental restrictions, and should be kept preserved. The work makes a valuable contribution to the understanding of the Baixada Massiambu problem, mainly related to land use, so that, through an environmental planning aimed at discussing mechanisms of reorganization of the territory, protective measures and environmental recovery can be formulated in this region.
300

Tratamento de água de abastecimento por nanofiltração e osmose inversa para remoção dos carbamatos

Tateoka, Marina Sampaio Slussarek January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T21:17:03Z (GMT). No. of bitstreams: 1 328326.pdf: 2264919 bytes, checksum: a4043c62260deda55cc11775d99bcf84 (MD5) Previous issue date: 2014 / A contaminação de águas por diversos produtos, entre eles, os defensivos agrícolas, tem exigido processos especiais de tratamento de água para removê-los. Assim, as membranas filtrantes representam uma alternativa, já que muitos contaminantes, mesmo aqueles de baixas massas molares, são removidos por essas tecnologias. Nesse contexto, o presente trabalho teve como objetivo avaliar a eficiência da remoção dos carbamatos carbaril, carbofurano e metomil, de água destilada e água de lagoa, ambas fortificadas com os carbamatos, através de membrana de nanofiltração e osmose inversa. Foram avaliadas diferentes concentrações na água de alimentação do sistema piloto de filtração, variando de 6 µg/L a 96 µg/L. Tanto a membrana de nanofiltração quanto a de osmose inversa foram eficientes, mas com desempenhos distintos, na remoção dos carbamatos. Quando em água destilada, a eficiência de remoção dos carbamatos pela membrana de nanofiltração atingiu 85%, 93% e 75% para carbaril, carbofurano e metomil, respectivamente. Para a membrana de osmose inversa o desempenho foi inferior, atingindo percentuais de 67%, 94% e 41%. Quando se utilizou água de lagoa, diferentes tipos de pré-tratamentos foram utilizados (coagulação, filtração direta, filtração em filtro cartucho de 5 µm, carvão ativado) e a eficiência dos mesmos foi calculada pelo teste SDI (Silt Densit Index) e MFI (Modified Fouling Index), porém, de acordo com esses critérios, os pré-tratamentos não foram eficientes para tratar a água para as membranas de nanofiltração e osmose inversa. Com relação a eficiência de remoção dos carbamatos através das membranas, quando utilizado água natural advinda da Lagoa do Peri fortificada com os mesmos, a membrana de nanofiltração apresentou retenções médias maiores do que quando utilizou-se água destilada. Estas remoções atingiram 98%, 99% e 90% para carbaril, carbofurano e metomil, respectivamente. O mesmo ocorreu para a membrana de osmose inversa com remoções de 84%, 100% e 63%, respectivamente. Verificou-se que no permeado, as concentrações dos carbamatos se mantiveram abaixo dos limites máximos permitidos por legislações brasileiras e internacionais.<br> / Abstract : Contamination of water with a variety of contaminants, among them the pesticides, has required special procedures to remove them. Thus, membrane technology represents an alternative, because that technology can remove many contaminants, even those of low molar weight. In this context, the present study evaluated the removal efficiencies of carbamates: carbaryl, carbofuran and methomyl, from distilled water and pond water, both fortified with carbamates, using nanofiltration and reverse osmosis membranes. Different concentrations of the contaminants were evaluated in the feed water, ranging from 6 µg/L to 96 µg/L. Both membranes were effective, but with different performances in the removal of carbamates. When distilled water was used, the pesticide removal efficiency of the nanofiltration reached 75%, 93% and 85% for methomyl, carbofuran and carbaryl, respectively. The results from reverse osmosis were 41%, 94% and 67%. When using pond water, different types of pre-treatments were used and effectiveness was calculated by testing SDI (Silt Densit Index) and MFI (Modified Fouling Index), however, according to these criteria , the pre - treatments did not were efficient in treating water for nanofiltration membranes and reverse osmosis. Regarding, the removal efficiency of carbamates through the membranes, when used natural water from the pond, Lagoa do Peri, fortified with pesticides, the nanofiltration membrane showed higher averages than when used distilled water. These removals reached 90 %, 99 % and 98 % for methomyl, carbofuran and carbaryl, respectively. The same was true for the reverse osmosis membrane with removals of 63 %, 100 % and 84 %, respectively. It was found that the permeate concentrations of pesticides is kept below the maximum allowed by Brazilian and international guidelines.

Page generated in 0.249 seconds