• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Combustão iniciada por microondas e determinação em linha de cádmio e chumbo em plantas por espectrometria de absorção atômica com tubo aquecido na chama

Bartz, Fabiane Regina 07 February 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work a new procedure is proposed by solid sampling flame furnace atomic absorption spectrometry after microwave induced combustion (MIC-FFAAS). The procedure was applied for the determination of cadmium and lead in botanical samples. Samples were groung, pressed and placed on a filter paper positioned on a quartz holder. The holder was placed in a glass device inside a microwave oven. The microwave oven was modified to make possible an oxygen inlet and the transport of the combustion products up to spectrometer. Amonium nitrate solution 50% (w/v) was used for the ignition step and O2 was used for combustion and transport of combustion products. Atomization was performed in a metalic heated tube positioned into air + acetylene flame. Deuterium background corrector was used throughout and calibration was carried out using reference solutions. After operational conditions optimization, the chosen parameters were: combustion using 20 mg of paper filter, 20 μL of NH4NO3 50% (w/v), 1 L min-1 O2 flow rate and use of tubes without modifications (for Cd) and with 12 holes (for Pb). Air and acetylene flow rates were 14 and 2 L min-1 (for Cd) and 12 and 2 L min-1 (for Pb), respectively. The system allowed the introduction up to 60 mg of sample and a quantification limit of 9.0 ng g-1 and 0.8 μg g-1, for Cd and Pb, respectively. The characteristic mass obtained was 55 pg for Cd and 4.1 ng for Pb. No significant differences were observed comparing the results using the proposed procedure with certified reference materials values or with those obtained by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry, after acid digestion. The device used for combustion and atomization may be easily coupled to flame atomic absorption spectrometters and the throughput was 20 determinations per hour, including the weighing step. / Neste trabalho é descrito um novo sistema para análise de amostras sólidas por espectrometria de absorção atômica com tubo aquecido na chama após combustão iniciada por microondas (MIC-FF-AAS). O procedimento foi aplicado para a determinação de cádmio e chumbo em plantas. No procedimento proposto as amostras foram moídas e prensadas na forma de comprimidos e colocadas sobre um papel de filtro posicionado em um suporte de quartzo. O suporte foi colocado no interior de uma câmara de vidro adaptada no interior de um forno de microondas. O forno de microondas foi modificado para possibilitar a entrada de oxigênio e a saída dos produtos da combustão. Uma solução de NH4NO3 50% (m/v) foi empregada como iniciador e O2 foi utilizado para a combustão e para o carreamento dos vapores formados até o sistema de atomização. A atomização foi feita em um tubo metálico posicionado na chama de um espectrômetro de absorção atômica com chama do tipo ar + acetileno e corretor de fundo com lâmpada de deutério. A calibração foi realizada empregando soluções de referência após combustão pelo sistema proposto. Após avaliação das condições operacionais, os seguintes parâmetros foram escolhidos: combustão empregando 20 mg de papel de filtro, 20 μL de solução de NH4NO3 50% (m/v) e 1 L min-1 como vazão de O2, vazão de ar e acetileno de 14 e 2 L min-1 para Cd e 12 e 2 L min-1 para Pb, respectivamente, uso de tubos de níquel sem modificações (para Cd) e com 12 furos na base (para Pb). O sistema permitiu a introdução de até 60 mg de amostra e um limite de quantificação de 9,0 ng g-1 e 0,8 μg g-1, para Cd e Pb, respectivamente. A massa característica foi de 55 pg para Cd e 4,1 ng para Pb. Resultados concordantes foram obtidos entre o sistema proposto e os valores para materiais de referência certificados ou com os obtidos por outras técnicas após digestão por via úmida (espectrometria de absorção atômica com forno de grafite e espectrometria de massa com plasma indutivamente acoplado). O sistema pode ser facilmente adaptado a espectrômetros de absorção atômica com chama convencionais e permitiu uma freqüência de 20 determinações por hora, incluindo a etapa de pesagem das amostras.
12

Desenvolvimento e validação de métodos analíticos para a determinação de contaminantes em polietileno tereftalato e polietileno de alta densidade pós-consumo / Development and validation of analytical methods for the determination of contaminants in polyethylene terephthalate and high-density polyethylene post consumer

Dutra, Camila Braga 16 August 2018 (has links)
Orientadores: Felix Guillermo Reyes Reyes, Maria Teresa de Alvarenga Freire / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-16T23:01:27Z (GMT). No. of bitstreams: 1 Dutra_CamilaBraga_D.pdf: 1974104 bytes, checksum: 7a0aae96f3654e27fb7d553ee756e522 (MD5) Previous issue date: 2010 / Doutorado / Doutor em Ciência de Alimentos
13

Avaliação do risco a exposição ocupacional a metais em incineradores de resíduos de serviços de saúde / Evaluation of the risk of metal occupational exposition in infectious waste incinerators

Intima, Danielle Polidorio 20 February 2004 (has links)
O trabalho teve como objetivo avaliar o risco a exposição ocupacional a metais em incineradores de resíduos de serviços de saúde, com o intuito de verificar as condições de trabalho das usinas de incineração, a fim de proteger a saúde dos trabalhadores do setor e evitar danos ao meio ambiente. Resíduos de serviços de saúde são resíduos sépticos caracterizados como resíduo Classe I por apresentarem patogenicidade, portanto, seu estudo é de extrema importância para a saúde pública e para qualidade do meio ambiente. Um dos processos de tratamento recomendado pela legislação para este tipo de resíduo consiste na incineração. Este processo baseia-se na decomposição térmica via oxidação, com o objetivo de minimizar a toxicidade e o volume dos resíduos. A presença de metais nos resíduos a serem incinerados é uma preocupação, pois este processo provoca a partição do metal presente nos resíduos de alimentação da câmara de combustão, podendo ocorrer sua emissão juntamente com as cinzas, ou com os resíduos do sistema de controle de poluição ou, até mesmo, através da chaminé dependendo de sua volatilidade. Em face desta problemática, faz-se necessária avaliação do risco ocupacional gerado pela exposição ao material particulado e aos gases tóxicos gerados pelo processo. Esta avaliação consiste na caracterização das partículas através da medição de seus constituintes em massa por volume de ar do ambiente de trabalho amostrado. Para isso, foi aplicada metodologia específica e reconhecida do National Institute of Organization Safety Health (NIOSH), o qual recomenda para a amostragem de mercúrio a utilização de resina hopcalite, e para os demais metais a utilização de filtro de éster de celulose. Como técnicas analíticas, este instituto recomenda a utilização da espectrometria de absorção atômica por geração de vapor frio para determinação de mercúrio e da espectrometria de emissão atômica com plasma de argônio induzido para os demais metais. De acordo com os resultados, foram obtidas concentrações acima do limite estabelecido para arsênio, berílio, cádmio, chumbo e mercúrio. Portanto, foram propostas alterações tecnológicas no processo e adequação dos equipamentos de proteção, com o intuito de proteger a saúde dos trabalhadores, da população e evitar danos ao meio ambiente. / This project aimed to evaluate the risk of metal occupational exposition in hospital waste incinerators, in order to verify the incineration plant work conditions, to protect the workers\' health and to avoid damage to the environment. Hospital waste is septic, characterized as Hazardous Waste (Class I) due to its patogenicity, therefore their study is extremely important for public health and environment quality. One of the legally recommended treatment processes to this kind of waste is the incineration. This process is based on thermal decomposition by oxidation, to minimize the toxicity and the waste volume. The presence of metal in the waste to be incinerated is a concern, because this process causes the partition of the metal present in the feeding waste of the combustion camera, which could lead to its emission together with the ash or even with the pollution control system waste, or, even, through the chimney, depending on its volatility. Due to this issue, occupational risk evaluation generated by exposition to particulate material and toxic gases emitted by the process rests necessary. This evaluation consists of particle characterization by measuring the constituents in mass per volume of the environmental sampling air. In order to reach it, specific and recognized methodology from the National Institute of Organization Safety Health (NIOSH) was applied, which recommends for mercury sampling the use of hopcalite resin, and for the other metaIs the use of cellulose filter. As analytic techniques, this institute recommends the use of cold vapor atomic absorption spectrometry to mercury determination and the inductively coupled plasma emission spectrometry to the other metals. According to the results, the obtained concentrations were above the limit established for arsenic, beryllium, cadmium, lead and mercury. Therefore, technological alterations were proposed in the process and adaptation of the protection equipments, in order to protect the employees\' health, the population health and to avoid damage to the environment.
14

Compostos voláteis e perfil sensorial de méis monoflorais produzidos por abelhas sem ferrão (melipona spp.) Do semiárido brasileiro

Costa, Ana Caroliny Vieira da 25 July 2017 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-09-05T12:00:46Z No. of bitstreams: 1 arquivototal.pdf: 3937791 bytes, checksum: fbf678d9dc4659707796320f30ad3bce (MD5) / Made available in DSpace on 2017-09-05T12:00:46Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3937791 bytes, checksum: fbf678d9dc4659707796320f30ad3bce (MD5) Previous issue date: 2017-07-25 / Stingless bees are producing honey with unique and high-value features; nonetheless, information about the volatile and sensorial profile of honeys produced by Melipona ssp. are scarce. This study aimed to characterize Monofloral honeys produced from flora / fauna of the northeastern semiarid region in order to determine potential chemical and sensorial markers (volatile compounds) to assist in attesting the authenticity of these honeys, which consequently contribute to the enhancement of melipoliculture activity. The samples, a total of twelve honeys, were produced by Jandaira species (Melipona subnitida Ducke) and uruçu (M. scutellaris Latrelle) and were collected in four different meliponaries, located in the region of Seridó, state of Rio Grande do Norte, and in the Agreste region, in the state of Paraiba. Through melissopalinological analysis, the samples were classified as Monofloral honeys of Juazeiro (Ziziphus joazeiro Mart.), velame branco (Croton heliotropiifolius Kunth), jurema branca (Mimosa arenosa willd poir), chanana (Turnera subulata L.), malicia (Mimosa quadrivalvis L.), angico (Anadenanthera colubrina) and algaroba (Prosopis juliflora Sw). The research initially involved the study of optimal conditions of Solid Phase Microextraction (SPME) technique for the extraction of volatile compounds of Monofloral honeys. Subsequently, honeys were evaluated by applying three analytical techniques: SPME applied to volatile analysis by GC-MS (HS-SPME-GC-MS), Quantitative Descriptive Analysis (QDA) and Gas Chromatography Olfactometry (GC-O). The optimization studies of SPME technique / GC / MS indicated the following optimized conditions: 15 minute equilibration time, 45 minutes extraction time and 45 ° C extraction temperature. A total of 161 volatile compounds, 13 belonging to chemical classes were identified in 12 samples evaluated. The profile of volatile compounds played an important role in determining floral source of honey, since the results suggest the existence of differentiators compounds and potential markers related to evaluated botanical sources. As an example, linalool to honeys from malicia, D-sylvestrene for honeys from chanana, rose-oxide for mesquite honey and benzeneethanol for angico honey. Honeys made from the blossoms from Juazeiro were sensorially sweeter, with aroma and flavor of more intense caramel. These honeys also showed a more characteristic flavor of honey, which can be associated with benzaldehyde compounds and benzene acetaldehyde. Honeys made from the velame branco flowerings were more acidic and less sweet, and were the only ones who showed volatile methyl eugenol in its composition, considered a character impact compound. Honeys from jurema branca showed higher aroma of beeswax; furthermore, compounds hexanol, limonene, α-farnesene and δ-cardinene may have contributed to generate the herbaceous aromas perceived with higher intensity in honeys produced in this bloom. Through olfactometry technique, it was found that chemical compounds pentanoate acetate, methyl eugenol, safranal and β-damascenone volatiles had a greater odor impact in white velame honey prepared by uruçu bee. It is emphasized that, in relation to the sensorial profile and volatile profile, statistically significant differences were observed (p ≤ 0.05) among honeys produced by different bees from the same botanical origin. In this context, the results show the strong influence of flowering in the volatile and sensory profile of monofloral honeys analyzed, representing an important contribution to knowledge related to aroma and flavor chemistry of this type of honey. Moreover, these are new results, which may be used in screening and evaluation of honey conformity, adding value to the product and the region, as well as help define marketing strategies and preservation of local culture and identity. / As abelhas sem ferrão são produtoras de méis com características únicas e elevado valor comercial; no entanto, informações acerca do perfil volátil e sensorial dos méis produzidos por Melipona ssp. são escassas. O presente estudo teve como objetivo caracterizar méis monoflorais produzidos a partir da flora/fauna da região semiárida nordestina, a fim de determinar potenciais marcadores químicos (compostos voláteis) e sensoriais que auxiliem na comprovação da autenticidade destes méis, o que consequentemente contribuirá para a valorização da atividade melicultora. As amostras, em um total de doze méis, foram produzidas pelas espécies jandaíra (Melípona subnitida Ducke) e uruçu (Melipona scutellaris Latrelle), tendo sido coletadas em quatro meliponários distintos, situados na região do Seridó do Estado do Rio Grande do Norte, e na região do Agreste do Estado da Paraíba. Através da análise melissopalinológica, as amostras coletadas foram classificadas como méis monoflorais de juazeiro (Ziziphus joazeiro Mart.), velame branco (Croton heliotropiifolius Kunth), jurema branca (Mimosa arenosa willd poir), chanana (Turnera subulata L.), malícia (Mimosa quadrivalvis L.), angico (Anadenanthera colubrina) e algaroba (Prosopis juliflora Sw). A pesquisa inicialmente envolveu o estudo das condições ótimas da técnica de Micro Extração em Fase Sólida (MEFS) para extração de compostos voláteis dos méis monoflorais. Posteriormente, os méis foram avaliados aplicando-se três técnicas analíticas: MEFS aplicada à análise de voláteis por CG-EM (HS-MEFS-CG-EM), Análise Quantitativa Descritiva (ADQ) e Cromatografia Gasosa Olfatometria (CG-O). Os estudos de otimização da técnica de MEFS/CG/EM indicaram as seguintes condições otimizadas: tempo de equilíbrio de 15 minutos, tempo de extração de 45 minutos e temperatura de extração de 45 °C. Um total de 161 compostos voláteis, pertencentes a 13 classes químicas, foi identificado nos doze méis avaliados. O perfil de compostos voláteis desempenhou um papel importante na determinação da origem floral do mel, uma vez que os resultados encontrados sugerem a existência de compostos diferenciadores e potenciais marcadores referentes às fontes botânicas avaliadas. Como exemplo, citam-se o linalol para méis de malícia, o D-silvestreno para méis de chanana, rose-oxide para mel de algaroba e o benzenoetanol para o mel de angico. Os méis elaborados a partir das floradas de juazeiro foram sensorialmente mais doces, apresentando aroma e sabor de caramelo mais intenso. Esses méis também apresentaram um aroma mais característico de mel, que pode estar associado aos compostos benzaldeído e benzenoacetaldeído. Os méis elaborados a partir das floradas de velame branco foram mais ácidos e menos doces, sendo os únicos que apresentaram em sua composição o volátil metil eugenol, considerado um character impact compound. Os méis de jurema branca apresentaram maior aroma de cera de abelha; além disso, os compostos hexanol, limoneno, α-farneseno e δ-cardineno podem ter contribuído para gerar os aromas herbáceos percebidos com maior intensidade nos méis produzidos nessa florada. Através da técnica olfatométrica, detectou-se que os compostos químicos - pentanoato de etila, metil eugenol, safranal e β-damascenona - foram os voláteis que tiveram maior impacto odorífero no mel de velame branco elaborado pela abelha uruçu. Enfatiza-se que, em relação ao perfil sensorial e ao de voláteis, não foram observadas diferenças estatisticamente significativas (p ≤ 0,05) entre os méis produzidos por abelhas diferentes a partir da mesma origem botânica. Neste contexto, os resultados evidenciam a forte influência da florada no perfil volátil e sensorial dos méis monoflorais analisados, representando uma contribuição importante para o conhecimento relacionado à química de aroma e sabor desse tipo de mel. Ademais, estes são resultados inéditos, que poderão ser utilizados na avaliação da conformidade do mel, agregando valor ao produto e à região, além 9 de contribuir para definir estratégias de comercialização e preservação da cultura e da identidade locais.
15

Analise de multirresiduos de antibioticos anfenicois e 'beta'-lactamicos em leite por cromatografia liquida de alta eficiencia acoplada ao detector de massas / Analysis of multirresiduos of antibiotics anfenicois and 'beta'-lactam antibiotics in milk by high performance liquid chromatography coupled to mass detector

Cunha, Mariem Rodrigues Ribeiro da 13 August 2018 (has links)
Orientador: Helena Teixeira Godoy / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-13T20:44:42Z (GMT). No. of bitstreams: 1 Cunha_MariemRodriguesRibeiroda_D.pdf: 2999287 bytes, checksum: e5698d30a669305197d9916533cf295f (MD5) Previous issue date: 2009 / Resumo: A presença de resíduos de antibióticos no leite resulta da aplicação de diferentes substâncias antimicrobianas no gado leiteiro para o tratamento de infecções e uso profilático na prevenção de doenças e como aditivos adicionados à ração para promover o crescimento do animal. A utilização indiscriminada dos antibióticos pode estar associada à presença de resíduos no leite e em seus derivados acima dos Limites Máximos de Resíduos (LMR) permitidos. A demanda por um controle da qualidade deste produto levou a necessidade de métodos analíticos confiáveis que permitam avaliar o teor desses resíduos, visando garantir a qualidade dos alimentos, a segurança do consumidor e o reconhecimento mútuo a nível internacional. Esta pesquisa descreve o procedimento de validação intralaboratorial de um método para identificar e quantificar resíduos de anfenicóis e de treze antibióticos da classe dos B-lactâmicos em leite UHT e em pó integrais por cromatografia líquida de alta eficiência acoplada ao espectrômetro de massas (CLAE/EM), de acordo com os critérios de validação preconizados pela Diretiva 2002/657/EC. Foram analisadas 475 amostras de leites integrais UHT e 140 em pó, perfazendo um total de 615 amostras. A coleta foi realizada pela Vigilância Sanitária dos estados de MG, RJ, SP, PR, RS, SC, ES, GO, MS, BA, PA e RO no período de julho/2006 a junho/2007. As amostras foram previamente submetidas ao ensaio de Kit SNAP e Kit ELIZA para cloranfenicol e B-Lactâmicos, respectivamente. O método por CLAE/EM foi utilizado para confirmar quantitativamente os antibióticos cloranfenicol, tianfenicol e florfenicol, e qualitativamente os B-lactâmicos (ampiclina, amoxicilina, cloxacilina, dicloxacilina, oxacilina, penicilinas G e V, cefapirina, cefalotin, cefazolin, cefoperazone e ceftiofur). Observou-se que 0,65% do total de amostras de leite UHT foram confirmadas, enquanto na triagem 4,11% foram reagentes. Para o leite em pó somente 1,44% do total de amostras foram confirmadas para florfenicol, enquanto na triagem 30,9% das amostras foram reagentes. Na triagem foi detectada a presença de resíduos de ß-lactâmicos em 3 amostras de leite UHT e 3 amostras de leite em pó. Em todas foi confirmada a presença do resíduo de cefapirina, representando, respectivamente, 0,65% e 2,14% do total das amostras. Os resultados mostraram que o método desenvolvido apresentou eficiência satisfatória ao uso pretendido / Abstract: The presence of antibiotic residues in milk resulting from the application of various antimicrobial substances in dairy cattle for the treatment of infections and prophylactic use in prevention of disease, before or after exposure, and added to feed additives to promote growth of the animal. Their indiscriminate use can be associated to the presence of residues in the milk and milk derivatives above the Maximum Limits of Residues (LMR) allowed. The demand for a control of the quality of this product, took to the development of reliable analytic methods that allow to evaluate the residue of antibiotics seeking to guarantee the quality of the victuals, the consumer's safety and the mutual recognition at international level. This study describes the procedure for intralaboratory validation of the method to identify and quantify residues amphenicols and thirteen antibiotics of the class of B¿lactams in UHT and powder milk by high performance liquid chromatography coupled to mass spectrometer. They were analyzed 475 UHT milk samples and 140 powder milk samples, covering a total of 615. The collection was carried by the Sanitary Surveillances of States of MG, RJ, SP, Pr, RS, SC, ES, GO, MS, BA and PA in the period from july 2006 to june 2007. The samples were previously submitted to Kit SNAP rehearsal and of Kit ELISA for chloranphenicol and B-lactamics respectively.The method of high performance liquid chromatography coupled with simple quadrupole mass detection (HPLC/MS) it was used to confirm quantitatively the chloranphenicol, thiamphenicol and florphenicol antibiotics and qualitatively the B-lactamics ampicillins, amoxicillin, cloxacillin, oxacillin, penicillins G and V, cephapirin, cephalothin, cefoperazone and ceftiofur antibiotics. It was found that 0.65% of total samples of milk were confirmed, while 4.11% were in the screening reagents. For milk powder only 1.44% of total samples were confirmed to florphenicol, while 30.9% in the screening of samples were reactive. Sorting to detected in the presence for residues of B-lactamics in three samples of milk an three samples of milk powder. In all samples the cephapirin, a B-lactamics class of cephalosporins, was aconfirmed, representin respectively 065% and 2.14 of total samples. The results showed that the method developed showed satisfactory performance to intended use / Doutorado / Mestre em Ciência de Alimentos
16

Desenvolvimento de metodologia analitica para determinação de codeina em plasma humano utilizando extração solido-liquido "on-line" acoplado ao HPLC-MS/MS / Analytical method development for determination of codeine in human plasma by on-line SPE-HPLC-MS/MS

Cruz, Alessandro de Carvalho 15 August 2018 (has links)
Orientador: Jose Pedrazzolli Junior / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-15T08:01:40Z (GMT). No. of bitstreams: 1 Cruz_AlessandrodeCarvalho_M.pdf: 6535924 bytes, checksum: 32e397fd65c63f6c293df90358e9eff3 (MD5) Previous issue date: 2010 / Resumo: Neste trabalho, a codeína foi determinada em plasma humano, através de metodologia analítica baseada no acoplamento da extração sólido-líquido "online" HPLC-MS/MS por electrospray positivo. O método foi desenvolvido visando a injeção direta de amostras plasmáticas sem prévio tratamento. O padrão interno utilizado foi o tramadol. O tempo total de análise foi de 3 min./amostra e devido ao sincronismo entre a corrida cromatográfica e a extração "on-line" automatizada o método possibilita a análise de mais de 400 amostras por dia. O uso de coluna monolítica (Chromolith Performance RP-18e, 100 mm x 4.6 mm) e extração em fase sólida automatizada (sistema Prospekt 2) demonstrou ser altamente eficiente em relação à resolução dos picos cromatográficos, tempo de retenção e pressão no interior da coluna cromatográfica. A curva de calibração foi definida com o intervalo de concentração de 5 à 200 ng/mL, atingindo boa linearidade. Excelentes resultados foram alcançados em relação à precisão e exatidão intra e inter-dia apresentando uma variação de 2.33 à 7.25% (CV%) e 2.35 à 9.97% (RE%), respectivamente. A metodologia analítica desenvolvida neste trabalho, baseada no acoplamento "on-line" SPE-HPLC-MS/MS apresentou boa seletividade, robustez, exatidão e precisão, bem como uma alta produtividade nas análises para determinação de codeína em plasma humano / Abstract: A specific LC-MS/MS method was developed and validated for automated determination of codeine in human plasma, using on-line solid-phase extraction (SPE) system coupled with positive ion electrospray ionization tandem mass spectrometry. Method allowed plasma direct injection onto cartridge without sample pre-treatment. Total analysis time per run was 3 min, allowing high-throughput for codeine determination. SPE on-line along monolithic column (Chromolith Performance RP-18e, 100 mm x 4.6 mm) demonstrated to be highly effective in terms of backpressure, separation speed and peak asymmetry. Calibration curves range was linear 5.0-200 ng/mL. Method showed an excellent intra-assay and inter-assay precision ranged from 2.33 to 7.25% (CV%) as well as great intra-assay and inter-assay accuracy, ranging from -2.35 to 9.97% (RE%). SPE-LC-MS/MS method provided selectivity, robustness, accuracy, precision and high-throughput to assess codeine pharmacokinetics in human plasma samples / Mestrado / Mestre em Farmacologia
17

Avaliação do risco a exposição ocupacional a metais em incineradores de resíduos de serviços de saúde / Evaluation of the risk of metal occupational exposition in infectious waste incinerators

Danielle Polidorio Intima 20 February 2004 (has links)
O trabalho teve como objetivo avaliar o risco a exposição ocupacional a metais em incineradores de resíduos de serviços de saúde, com o intuito de verificar as condições de trabalho das usinas de incineração, a fim de proteger a saúde dos trabalhadores do setor e evitar danos ao meio ambiente. Resíduos de serviços de saúde são resíduos sépticos caracterizados como resíduo Classe I por apresentarem patogenicidade, portanto, seu estudo é de extrema importância para a saúde pública e para qualidade do meio ambiente. Um dos processos de tratamento recomendado pela legislação para este tipo de resíduo consiste na incineração. Este processo baseia-se na decomposição térmica via oxidação, com o objetivo de minimizar a toxicidade e o volume dos resíduos. A presença de metais nos resíduos a serem incinerados é uma preocupação, pois este processo provoca a partição do metal presente nos resíduos de alimentação da câmara de combustão, podendo ocorrer sua emissão juntamente com as cinzas, ou com os resíduos do sistema de controle de poluição ou, até mesmo, através da chaminé dependendo de sua volatilidade. Em face desta problemática, faz-se necessária avaliação do risco ocupacional gerado pela exposição ao material particulado e aos gases tóxicos gerados pelo processo. Esta avaliação consiste na caracterização das partículas através da medição de seus constituintes em massa por volume de ar do ambiente de trabalho amostrado. Para isso, foi aplicada metodologia específica e reconhecida do National Institute of Organization Safety Health (NIOSH), o qual recomenda para a amostragem de mercúrio a utilização de resina hopcalite, e para os demais metais a utilização de filtro de éster de celulose. Como técnicas analíticas, este instituto recomenda a utilização da espectrometria de absorção atômica por geração de vapor frio para determinação de mercúrio e da espectrometria de emissão atômica com plasma de argônio induzido para os demais metais. De acordo com os resultados, foram obtidas concentrações acima do limite estabelecido para arsênio, berílio, cádmio, chumbo e mercúrio. Portanto, foram propostas alterações tecnológicas no processo e adequação dos equipamentos de proteção, com o intuito de proteger a saúde dos trabalhadores, da população e evitar danos ao meio ambiente. / This project aimed to evaluate the risk of metal occupational exposition in hospital waste incinerators, in order to verify the incineration plant work conditions, to protect the workers\' health and to avoid damage to the environment. Hospital waste is septic, characterized as Hazardous Waste (Class I) due to its patogenicity, therefore their study is extremely important for public health and environment quality. One of the legally recommended treatment processes to this kind of waste is the incineration. This process is based on thermal decomposition by oxidation, to minimize the toxicity and the waste volume. The presence of metal in the waste to be incinerated is a concern, because this process causes the partition of the metal present in the feeding waste of the combustion camera, which could lead to its emission together with the ash or even with the pollution control system waste, or, even, through the chimney, depending on its volatility. Due to this issue, occupational risk evaluation generated by exposition to particulate material and toxic gases emitted by the process rests necessary. This evaluation consists of particle characterization by measuring the constituents in mass per volume of the environmental sampling air. In order to reach it, specific and recognized methodology from the National Institute of Organization Safety Health (NIOSH) was applied, which recommends for mercury sampling the use of hopcalite resin, and for the other metaIs the use of cellulose filter. As analytic techniques, this institute recommends the use of cold vapor atomic absorption spectrometry to mercury determination and the inductively coupled plasma emission spectrometry to the other metals. According to the results, the obtained concentrations were above the limit established for arsenic, beryllium, cadmium, lead and mercury. Therefore, technological alterations were proposed in the process and adaptation of the protection equipments, in order to protect the employees\' health, the population health and to avoid damage to the environment.
18

Avaliação das taxas de doses de radiação gama e modelagem cartografica das estatisticas de obitos por neoplasias na região central de Cuba / Evaluation of the gamma radiation dose rates and cartographic modeling of the death statistics by neoplasies in the central region of Cuba

Padilla Rodriguez, Ingrid 26 August 2005 (has links)
Orientador: Elisabete Maria Pascholati / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-08-05T05:12:34Z (GMT). No. of bitstreams: 1 PadillaRodriguez_Ingrid_D.pdf: 8041053 bytes, checksum: 09d5970b48a5198700990c2513a29e66 (MD5) Previous issue date: 2005 / Resumo: O estudo desenvolvido visa avaliar as taxas de doses de radiação gama, na região central de Cuba, explorando as possibilidades do levantamento aerogeofisico na caracterização radiogeoquímica e mapeamento geólogo - estrutural do meio ambiente numa área de aproximadamente 16.500 km2. Adicionalmente, é propósito dispor de resultados que contribuam ao estabelecimento de uma linha base ambiental, baseado no background a radiação gama terrestre, de grande interesse para o sistema de vigilância radiológica acional. As estatísticas sobre óbitos por neoplasias do tipo tumores sólidos na região central de Cuba, a qual apresenta o segundo lugar nas ocorrências de casos no país, induz à seguinte hipótese para a pesquisa: "a radiogeoquímica desses ambientes geológicos poderia gerar taxas de doses de radiação gama correlacionáveis aos resultados estatísticos obtidos para a população dos vinte e sete municípios envolvidos?" Com este fim, foram modeladas, analisadas estatisticamente e interpretadas, as variáveis geólogo-geofisicas independentes, de relevo, epidemiológicas e censitárias num ambiente SIG sobre as populações envolvidas, para estabelecer uma possível relação com a taxa de dose estimada para a região central de Cuba. Este procedimento revelou uma razoável representatividade da diversidade geológica do meio ambiente, vinculando-a aos casos registrados e probabilisticamente esperados na população. A geologia na região é representada por vários ambientes: as unidades da margem continental da plataforma das Bahamas (Jurássico Superior - Cretáceo Superior), os ofiolitos Mesozóicos com imbricações das rochas do arco de ilha Vulcânico do Cretáceo (AVC), a cobertura neo-plataformal Cenozóica, as metavulcânicas da fácies xisto verde e os anfibolitos na divisa com as várias unidades lito-tectônicas (Jurássico Inferior - Cretáceo Superior) do Terreno metamórfico Escambray. As principais análises basearam-se rio processamento e na interpretação dos dados gamaespectrométricos aéreos. Embora os contrastes dos teores obtidos sobre os litotipos e as estruturas, sejam sutis as diversidades do ambiente geológico é mapeada com clareza. Através da cartografia como um todo, e das componentes principais, em particular, pode-se reconhecer a, correlação das concentrações Th-U, com relativa predominância do primeiro no platô litorâneo e parcialmente, nas bacias frontais e superpostas ao AVC e nos sedimentos recentes. Observam-se mudanças nos teores de potássio proporcionalmente ao conteúdo de sílica nas rochas ácidas e intermediárias - ácidas, ultrapassando levemente 3,0 %, nos plagiogranitos na divisa do AVC com o complexo Mabujina e, muito localmente, nos sedimentos do Terciário: Os teores Th - U atingem níveis relativamente maiores e anômalos nos sedimentos continentais da plataforma das Bahamas, setor que contém biodetríticos com fosfatos, baixas concentrações residuais de zircônio, monazita e/ou elementos componentes das terras raras, os quais ficaram possivelmente retidos, apesar da movimentação nos processos exógenos, mas sem interesse para a mineração. Embora misturado com as rochas dó AVC, a extensa faixa de ofiolitos é reconhecida pelos baixos níveis dos radioelementos.Também foram mapeadas a faixa de acrescência e sutura entre as rochas' metamórficas do Terreno Escambray e o Complexo . Mabujina, no limite norte, com as rochas do AVc. Existem evidências também de algumas diferenças geomorfológicas na formação de solos e sua relativa movimentação nos córregos e rios da região. ... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: This study developed in the central part of Cuba, attempted to evaluate a gamma radiation dose rate, exploring the airbome geophysical survey possibilities in order to obtain a radiogeochemical characterization and the geological - structural mapping of environment for an area of about 16.500 km2. Besides, to dispose through this research, of results that contribute to the establishment of the environmental base tine, based on the background of the gamma terrestrial radiation and its possible relationships in the context, is interest fqr the system of surveillance national radiological. The statistical data about deaths for neoplasies of the type solid tumors in the region, the one which presents the second one place of occurrences of cases in the country, it induces the followirig hypothesis: "could be those environment be able to generate gamma radiation dose rates correlated with the statistics facts, that reach the population of the twenty-seven involved municipal districts?" . With this intent, several independent landscape variables (geological, geophysical, physiographic, epidemiologic ones and related to the population's census), Were modeled and analyzed using GIS, in order to establish a possible relationship with the mean value about the dose'rate estimated in the central region. This procedure provided a reasonable representation of the environmental geological diversity, linking it to current cases incidences and expected probabilistic, in the population. The geological diversity m the area is composed by the units of the margm of the Bahamas contmental platform (Upper Jurassic - Upper Cretaceous), for the Mesozoic ophiolites, partially blended and superimposed for the volcanic rocks of the arch of islands Cretaceous (CVA), for the Cenozoic Neo-platform cover, for the meta - vo1canicrocks of green schist facies and amphibolites m the limits with the litho-tectonic units (Lower Jurassic - Upper Cretaceous) of the metamorphic Escambray Terram.... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Metalogenese / Doutor em Ciências
19

Distribuição espacial de HPA em sedimentos do estuário Piauí-Real

Santos, Ewerton 23 July 2015 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Polycyclic aromatic hydrocarbons are organic compounds present in the environment and considered potentially pollutants, in addition to have carcinogenic and mutagenic properties. These compounds are widespread in the different environment compartments, thus, the aim of this study is to validate a method for determination of 16 polycyclic aromatic hydrocarbons (PAH) prioritized by the United States Environmental Protection Agency (USEPA) in sediments. The samples were collected in the Piauí-Real estuarine system, located in the state of Sergipe. The validated method is based in the use of ultrasound extraction and gas chromatography with mass spectrometry detector analysis. We evaluated seven parameters for the validation: selectivity, linearity, detection and quantification limit, precision, accuracy and robustness. The results are considered satisfactory when compared to guidelines of specialized agencies, such as INMETRO, which enables the method application with reliability and safety requirements. In the samples analysis, the distribution of HPA is in the range of 4.9 and 301 ng g-1 of dry sediment. The use of diagnostic reasons made the evaluation of sources contamination possible, where most of the samples was considered uncontaminated and inputted from mixing sources. / Os hidrocarbonetos policíclicos aromáticos são compostos orgânicos presentes no meio ambiente e considerados potencialmente poluidores, além de apresentarem características carcinogênicas e mutagênicas. Estes compostos estão presentes nos vários compartimentos ambientais. Dessa forma, o objetivo deste trabalho foi validar um método para a determinação de 16 hidrocarbonetos policíclicos aromáticos (HPA) considerados prioritários pela Agência Nacional de Proteção Ambiental dos Estados Unidos (USEPA) em matrizes sedimentares. As amostras foram coletadas no estuário Piauí Real região sul do Estado de Sergipe. O método validado baseia-se na extração por ultrassom e análise por cromatografia gasosa com detector de massas. Foram avaliados setes parâmetros para a validação do método: seletividade, linearidade, limite de detecção e quantificação, precisão, exatidão e robustez. O método apresentou resolução adequada para grande parte dos compostos analisados, tanto em amostras preparadas em n-hexano quanto para extratos da amostra. A linearidade foi estimada através do coeficiente de correlação, onde apresentou valores acima de 0,99 para todos os HPA, enquanto que os limites de detecção e quantificação variaram entre 0,1 a 1,0 ng mL-1 e 0,3 a 3,0 ng mL-1, respectivamente. Os teores de recuperação dos analitos variaram entre 72 a 115%. A avaliação dos desvios-padrão foram realizadas para estimar exatidão, foram obtidos valores que variaram entre 2 e 15%. Para avaliação da robustez, foi realizado através de gráficos de Pareto, nestes foi possível observar que o método não apresenta robustez adequada para todos os compostos. Nas análises das amostras, a distribuição dos HPA apresentou variação entre 4,9 301 ng g-1 de sedimento seco. A utilização de razões diagnósticas permitiu avaliar possíveis fontes de contaminação, sendo que grande parte das amostras foi considerada não contaminada e depositada no meio a partir de mistura de fontes.
20

Determinação de clorpropamida em plasma empregando empregando cromatografia liquida de alta eficiencia acoplada a espectrometria de massa sequencial (LC/MS/MS) e sua aplicação em um estudo de bioequivalencia / Determination of chlorpropamide in plasma, using high-performance liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) and their application in a study of bioequivalence

Silva, Márcia Aparecida da 20 August 2007 (has links)
Orientador: Gilberto de Nucci / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T03:36:14Z (GMT). No. of bitstreams: 1 Silva_MarciaAparecidada_D.pdf: 10125609 bytes, checksum: 145f4a9b65da8eb2521c6f76e1d715a9 (MD5) Previous issue date: 2007 / Resumo: A biodisponibilidade relativa, de duas formulações de comprimido de clorpropamida 250 mg, foi avaliada em voluntários sadios de ambos os sexos. O estudo foi aberto, aleatorizado, cruzado em dois períodos com intervalo de três semanas, para o qual foram selecionados 36 voluntários. As amostras de sangue foram coletadas antes da administração de dose única de cada formulação, uma Teste (T) e outra Referência (R) e durante 72 horas após a administração. A concentração plasmática de clorpropamida foi determinada por cromatografia líquida de alta eficiência acoplada à espectrometria de massa seqüencial (LC/MS/MS), usando ionização tipo eletrospray no modo positivo com monitoramento de reação múltipla (MRM). O limite de quantificação foi de 0,1 µg/mL. O padrão interno foi a glibenclamida. A ASC0-72, que representa ASC truncada, Cmax e Tmax foram obtidas da curva de concentração plasmática em função do tempo. A ASC foi calculada empregando o método trapezoidal. Apenas ASC0-72 e Cmax de ambas as formulações foram estatisticamente comparados. A média geométrica e o intervalo de confiança (90%) da razão T/R foram respectivamente 93,99 (87,11%¿101,41%) para Cmax e 92,45 (85,96%-99,44%) para ASC0-72. Como o intervalo de confiança (90%), para ASC0-72 e Cmax, apresenta-se dentro do intervalo de confiança de 80-125% proposto pela Agência Nacional de Vigilância Sanitária (Anvisa) e pelo Food and Drug Administration (FDA-EUA), concluiu-se que ambas as formulações estudadas são bioequivalentes, no que diz respeito à magnitude e a velocidade de absorção e, portanto podem ser clinicamente intercambiáveis sem prejuízo terapêutico. Palavras-chave: Clorpropamida, bioequivalência, HPLC acoplada à espectrometria de massa seqüencial (LC/MS/MS), biodisponibilidade, farmacocinética / Abstract: The relative bioavailability between two formulations of chlorpropamide was assessed on the dosage form tablet 250 mg, in healthy volunteers of both sexes. The study was conducted using an open, randomized, two-period crossover design with the 3-week washout interval. Thirty-six subjects were selected. The blood samples were collected at the time prior to dosing and over an interval of 72 hours, of the single dose of each formulation, a Test (T) and another Reference (R). Chlorpropamide plasma concentrations were analyzed by high performance liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) with positive ion electrospray ionization using multiple reaction monitoring (MRM). The limit of quantification was 0,1 µg/mL for plasma Chlorpropamide analysis. The internal standard was the glibenclamide. The AUC 0-72, which represents AUC truncated, Cmax and Tmax were obtained from plasma concentration-time curve. The AUC was calculated using the trapezoidal rule. Only AUC0-72 and Cmax of the each other formulations were statistically compared. The geometric mean and respective 90% confidence interval (CI) of T/R ratios were 93.99 (87.11%¿101.41%) for Cmax and 92.45 (85.96%-99.44 %) for AUC0-72. Since the interval confidential (90%) for AUC0-72 and Cmax ratios were within the 80-125% interval proposed by the Agência Nacional de Vigilância Sanitária-Brazil (Brasil-Anvisa) and by the Food and Drug Administration (USA-FDA), it was concluded that both the formulations studied are bioequivalent for both the rate and extent of absorption and, therefore can be used interchangeably without impairing therapeutic effectiveness. Key words: Chlorpropamide, bioequivalence, high performance liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS), bioavailability, pharmacokinetic / Doutorado / Doutor em Farmacologia

Page generated in 0.0865 seconds