• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • Tagged with
  • 35
  • 35
  • 35
  • 13
  • 9
  • 9
  • 9
  • 9
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da viabilidade da determinação de cobalto e cromo em alimentos por espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS). / Evaluation of the feasibility of cobalt and chromium determination in foods by thermospray flame furnance atomic absorption spectrometry (TS-FF-AAS).

Donati, George Luís 23 February 2006 (has links)
Made available in DSpace on 2016-06-02T20:36:58Z (GMT). No. of bitstreams: 1 DissGLD.pdf: 1135923 bytes, checksum: a01e5691bc8173353509b5a00f4b3c7d (MD5) Previous issue date: 2006-02-23 / Universidade Federal de Sao Carlos / In this work, a nickel tube used as atomization cell and a ceramic capillary for thermospray generation (TS-FF-AAS) were employed to increase the analytical performance of the flame atomic absorption spectrometry (FAAS). The applicability of the method was evaluated for Co(II) and Cr(III) determination in food samples. Due to factors such as the low temperature into the atomization tube, the high atomization temperatures of the analytes, and the low levels of these elements in biological samples, a cloud point extraction (CPE) method was applied to both improve the processes of volatilization and atomization by formation of volatile metal complexes, and increase the sensitivity. Triton X-114 was used as surfactant to the implementation of the cloud point preconcentration procedure and, after the evaluation of several complexing agents, the best results were obtained with ammonium pyrrolidinedithiocarbamate (APDC). Parameters such as pH of complexation and concentrations of both surfactant and complexing agent were optimized. To improve the sensitivity, two configurations were evaluated to change the internal temperature of the atomization tube. The slotted tube, in which the internal temperature is higher due to more intense flame penetration, provided a significant increase in Cr(III) sensitivity. Parameters such as flame stoichiometry, atomization tube height, rich phase solvent, sample volume, carrier and flow rate were also evaluated. Limits of detection (LOD) of 2.1 and 2.5 µg L-1 and quantification (LOQ) of 7.0 and 8.4 µg L-1 (n = 10) for Co(II) and Cr(III), respectively, were obtained using optimized conditions. Intermediate precision (5.8 and 5.4 % for Co(II) and Cr(III), respectively), presented as relative standard deviation (RSD, %, 1s), were calculated from 10 consecutive readings of both analytes preconcentrated solutions. Interferences were observed in both volatilization and atomization processes into the atomization tube, as well as in the reactions of metal complexes formation due to both the complexity of the sample and the high concentrations of concomitants. A procedure based on extraction with 1 mol L-1 HCl was adopted for Co(II) determination. Only divalent species are quantitatively extracted. On the other hand, critical interferents, such as Fe(III) and Al(III), are not extracted. Procedures for interferents complexation with either fluorides or ethylenediaminetetraacetic acid (EDTA) were evaluated for Cr(III) determination. Method accuracy was checked by Co(II) determination in two certified reference materials (tomato leaves and bovine liver). There were no statistical differences between determined and certified values in a 95 % confidence level. The proposed method is efficient and allowed the determination of trace concentrations of Co(II) in foods without the need of sample digestion. However, the Cr(III) determination in foods was not possible due to the sample complexity and the interferences caused by concomitants in both preconcentration and determination steps. / Neste trabalho, um tubo de níquel usado como célula de atomização e um capilar cerâmico para a geração de um aerossol térmico (TS-FF-AAS) foram empregados para a melhoria do desempenho analítico da espectrometria de absorção atômica com chama (FAAS). Avaliou-se a aplicabilidade do método para a determinação de Co(II) e Cr(III) em amostras alimentícias. Devido a fatores como a baixa temperatura no interior do tubo atomizador, as altas temperaturas requeridas para atomização e os baixos teores desses elementos em amostras biológicas, foi aplicado um método de extração por ponto nuvem (CPE) visando favorecer os processos de volatilização e atomização pela formação de complexos metálicos voláteis e aumentar a sensibilidade pela pré-concentração dos analitos. Para a implementação do procedimento de pré-concentração por ponto nuvem foi empregado o surfactante Triton X-114 e, na avaliação de diversos complexantes, os melhores resultados foram obtidos para pirrolidinaditiocarbamato de amônio (APDC). Fatores como pH de complexação e concentrações do complexante e do surfactante foram otimizados. Visando ao aumento da sensibilidade, dois tipos de configuração foram avaliados para aumentar a temperatura interna do tubo atomizador. O tubo com maior orifício, cuja temperatura interna é maior devido a uma melhor penetração da chama, apresentou um aumento significativo na sensibilidade para Cr(III). Foram também avaliados parâmetros como estequiometria da chama, altura do tubo atomizador em relação ao queimador, solvente da fase rica, volume de amostra, carregador e vazão. A partir das condições otimizadas foram obtidos limites de detecção (LOD) de 2,1 e 2,5 µg L-1 e limites de quantificação (LOQ) de 7,0 e 8,4 µg L-1 para Co(II) e Cr(III), respectivamente (n = 10). A repetibilidade do método (5,8 e 5,4 % para Co(II) e Cr(III), respectivamente), representada como desvio padrão relativo (RSD, %, 1s), foi calculada a partir de 10 medidas consecutivas de soluções pré-concentradas dos analitos. Foram observadas interferências tanto nos processos de volatilização e atomização no interior do tubo atomizador como na reação de formação dos complexos metálicos devido à complexidade da amostra e às altas concentrações de concomitantes presentes nas amostras analisadas. Na determinação de Co(II), para evitar tais efeitos, foi aplicado um procedimento de extração ácida com solução de HCl 1 mol L-1, no qual apenas espécies divalentes são quantitativamente extraídas enquanto interferentes críticos como Fe(III) e Al(III) não o são. Para Cr(III) foram avaliados procedimentos de complexação dos concomitantes com fluoreto e com ácido etilenodiaminatetraacético (EDTA). A exatidão do método foi verificada pela determinação de Co(II) em dois materiais de referência certificados (folhas de tomateiro e fígado bovino). Não houve diferenças estatísticas entre os teores determinados e certificados em um nível de confiança de 95%. O método é eficiente e possibilitou a determinação de Co(II) em baixas concentrações em amostras comerciais de origem vegetal e animal sem a necessidade de digestão da amostra. Contudo, a determinação de Cr(III) em amostras alimentícias foi impossibilitada devido às altas concentrações e às interferências causadas por concomitantes nas etapas de pré-concentração e determinação.
22

Desenvolvimento de métodos analíticos empregando a espectrometria de absorção atômica sequencial rápida com atomização em chama / Development of analytical methods employing fast sequential atomic absorption spectrometry with flame atomization

Miranda, Kelber dos Anjos de 19 February 2012 (has links)
Made available in DSpace on 2016-06-02T20:34:36Z (GMT). No. of bitstreams: 1 4531.pdf: 708473 bytes, checksum: fa2ea780712d3ffbd332ab95fd4c9dff (MD5) Previous issue date: 2012-02-19 / Universidade Federal de Sao Carlos / The aim of this PhD thesis was to develop analytical methods employing fast sequential flame atomic absorption spectrometry (FS-FAAS). In the first part of this study, a fast and simple method is proposed for the determination of Cu in sugar cane spirits employing FS-FAAS and the internal standard technique. First, Ag, Bi, Co and Ni were evaluated as internal standards to correct transport interferences caused by the presence of ethanol. The results demonstrated that Ag at a concentration of 2 mg L−1 was effective as internal standard. In the second part of this study, a novel analytical method which consists of a combination of hydride generation and FS-FAAS is proposed. The method developed was employed for the sequential determination of As and Sb at sub-μg L-1 levels in bottled mineral waters. An enhancement in the analytical throughput was obtained when compared with the traditional monoelement HGAAS with a quartz tube atomizer. In the last part of the study, the combination of thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) and FS-FAAS for the sequential determination of Cd, Cu, Pb and Zn was proposed and a significant improvement in the analytical throughput of TS-FFAAS was obtained. Then, an analytical method for the sequential determination of Cd, Cu and Pb in slurries of biological samples by TS-FF-AAS was developed. / Esta tese de doutorado teve como objetivo o desenvolvimento de métodos analíticos empregando a espectrometria de absorção atômica sequencial rápida com atomização em chama (FS-FAAS). Na primeira parte do estudo, avaliou-se o uso da padronização interna em FS-FAAS através da determinação direta de Cu em amostras de aguardente de cana. Neste caso, Ag, Bi, Co e Ni foram avaliados como padrões internos para a correção do efeito de transporte causado pela presença de etanol na matriz. Os resultados demostraram que Ag na concentração de 2 mg L−1 foi eficaz como padrão interno na determinação direta de Cu em amostras de aguardente por FS-FAAS. Na segunda parte do estudo, avaliou-se o potencial do acoplamento entre a geração de hidretos (HG) e a FS-FAAS para a determinação sequencial de As e Sb em amostras de água mineral. Os resultados revelaram que a HG no modo multielementar proporcionou um aumento considerável da frequência analítica, redução do consumo de reagentes e diminuição da geração de resíduos em relação à HG no modo monoelementar. Na última parte do estudo, avaliou-se o potencial da união da espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS) com a FS-FAAS para a determinação sequencial de Cd, Cu, Pb e Zn. Os resultados evidenciaram o aumento da frequência analítica proporcionada pela TS-FF-AAS no modo multielementar em relação ao modo monoelementar. Em seguida, amostras biológicas foram prédigeridas e introduzidas na forma de suspensões no sistema TS-FF-AAS para a determinação sequencial de Cd, Cu, Pb e Zn.
23

Avaliação do comportamento das elementos Ni, Rb e Se por espectrometria de absorção atômica com forno tubular na chama de aeressol térmico. / Evaluation of valuation of the behavior of Ni, Rb and Se by thermospray flame furnace atomic absorption spectrometry.

Rosini, Fabiana 30 June 2006 (has links)
Made available in DSpace on 2016-06-02T20:36:09Z (GMT). No. of bitstreams: 1 DissFR.pdf: 954202 bytes, checksum: 5f8328894ac65766848302e809f713ba (MD5) Previous issue date: 2006-06-30 / Financiadora de Estudos e Projetos / In the present work the behavior of the elements Ni, Rb, and Se was evaluated by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). The arrangement of the TS-FF-AAS system consisted of a Ni tube located on the burner head of an air / acetylene flame with a ceramic capillary tube connected to it and heated by the flame. The sample was transported towards the capillary heated tube by action of a peristaltic pump, and then transformed in a thermospray that was introduced into the Ni tube. The sensitivity was increased by the complete introduction of the sample in the absorption volume. For all tested elements, the effect of the main parameters on atomization, such as flame composition, observation height, type of carrier stream, flow rate, and sample volume, was investigated. For selenium, the detection limit obtained was 95-fold better than that obtained by FAAS. Notwithstanding, selenium determination was difficult due to the absorption region of this element (λ = 196 nm), that implied in molecular absorption by flame gases and scattering of radiation. Based on prescribed conditions established by a factorial experiment, selenium was determined with accuracy in samples of animal tissues and in two standard reference materials after microwave-assisted digestion using a diluted solution of acid nitric. For Rb, the sensitivity increased 37-fold compared to FAAS, leading to a detection limit of 2.65 µg/L by TS-FF-AAS. On the other hand, Ni is a refractory element and needed special conditions to facilitate the volatilization and atomization processes. Thus, a cloud point extraction procedure was developed. The combination of both TS-FF-AAS and cloud point extraction led to an improvement of 18-fold in detection limit, however Ni determination in biological samples was limited owing to interferences caused by Al(III), Co(II), and Fe(III). These interferences could be solved by adding fluoride to the digests. / Neste trabalho, avaliou-se o comportamento dos elementos Ni, Rb e Se por espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS). A montagem do sistema TS-FF-AAS consistiu de um tubo atomizador de Ni posicionado sobre o queimador de ar / acetileno. Com o auxílio de uma bomba peristáltica e um capilar cerâmico aquecido pela chama, a amostra foi convertida em um aerossol e transportada para o interior do tubo atomizador de Ni. A sensibilidade foi aumentada devido à completa introdução da amostra no caminho óptico e ao aumento do tempo de permanência do analito na zona de observação. Para todos os elementos, parâmetros como composição da chama, altura de observação (posição do tubo em relação à chama), tipo e vazão do carregador e volume da amostra foram investigados na atomização do analito. Para o Se, o limite de detecção obtido foi 95 vezes menor que o apresentado por FAAS. A determinação desse elemento é dificultada, pois o Se absorve em uma região (λ = 196 nm) onde ocorre absorção dos próprios gases da chama e o espalhamento de radiação é mais acentuado. Mesmo considerando-se essas dificuldades experimentais, a determinação exata de Se por TS-FF-AAS foi possível para amostras de tecidos animais usando digestão em forno de microondas com cavidade e HNO3 diluído. Para o Rb também houve ganho na sensibilidade de 37 vezes comparativamente à FAAS, obtendo-se um limite de detecção por TS-FF-AAS de 2,65 µg/L. Por outro lado, o Ni é um elemento refratário e necessita de condições especiais para facilitar os processos de volatilização e atomização. Dessa forma, optou-se por desenvolver um procedimento de pré-concentração e extração no ponto nuvem. A combinação desses procedimentos com TS-FF-AAS proporcionou uma melhoria no limite de detecção de 18 vezes, mas a determinação de Ni em amostras biológicas foi dificultada devido às interferências causadas por Al(III), Co(II) e Fe(III). Essas interferências podem ser corrigidas adicionando-se fluoreto aos digeridos.
24

Desenvolvimento de método analítico com emprego da espectrometria de absorção atômica para a determinação de Cd, Fe, Pb e Zn em amostras de interesse alimentício

Col, José Augusto da 31 July 2008 (has links)
Made available in DSpace on 2016-06-02T20:36:11Z (GMT). No. of bitstreams: 1 1908.pdf: 689524 bytes, checksum: 6e4c524edf39c43db6f34174bc540324 (MD5) Previous issue date: 2008-07-31 / Universidade Federal de Sao Carlos / Analytical chemistry plays a fundamental role in proposing fast and reliable procedures to analyze food samples. Proper selection and introduction of complementary foods reduces the vulnerability to micronutrient deficiencies. This study aimed to propose a sensitive approach for the promotion of adequate food supplements regarding Cd, Fe, Pb and Zn contents. For the development of this method, factorial design was used for experimental conditions optimization. These metals were determined using Flame Atomic Absorption Spectrometry - FAAS (Fe and Zn) and Thermospray Flame Furnace AAS (Cd and Pb). In TS-FF-AAS, a nickel tube is used as atomizer; since the sample is totally introduced into the tube, an increase in method sensitivity is obtained. Besides, flame residence time is extended, increasing efficiency of atomizing processes. Additionally, a simple procedure mixing the sample (100 mg) with 0.1 mol/L HCl was proposed. In food analysis, limits of detection (LOD) of 0.6, 100, 6.0 and 32 µg/L for Cd, Fe, Pb and Zn were obtained, respectively. Standard Relative Deviations (RSD) for elements Cd (n = 14), Fe (n = 3) and Zn (n = 19) were of 7.0, 5.5 and 6.0%, respectively. Analytical frequency of the method was of 28 determinations per hour with an analytical speed of 8 samples per hour (from sample preparation to determination). All determinations were performed with the same atomizing tube, which, even after 2270 determinations (around 76 h), did not present sensitivity losses. Cadmium and Zn showed suitable results when a bovine liver certified sample (SRM 1577b) was studied and the Fe content was strongly correlated to the size of the particle. Toxic metals Cd and Pb were not detected in the studied food samples. Regarding the essential elements, there was no increase in the Fe and Zn when the supplement is used. Information about food quality could be obtained, and the proposed method fits the purpose. / A Química Analítica desempenha um papel fundamental na proposição de procedimentos rápidos e confiáveis para a análise de alimentos. A adequada seleção e introdução de alimentos complementares reduz as deficiências de micronutrientes. Este estudo teve como objetivo a proposição de um método para se verificar o uso de suplementos alimentares adequados com relação às concentrações dos elementos Cd, Fe, Pb e Zn. No desenvolvimento deste método foi utilizado o planejamento fatorial como ferramenta para sua otimização das condições experimentais. Os metais foram determinados por espectrometria de absorção atômica com chama - FAAS (Fe e Zn) e por espectrometria de absorção atômica com forno tubular na chama e aerossol térmico - TS-FF-AAS (Cd e Pb). Em TS-FF-AAS, um tubo de níquel é utilizado como atomizador e, dessa forma, um aumento na sensibilidade do método é conseguido, uma vez que toda a amostra é inserida no interior do tubo. Além disso, o tempo de residência na chama é prolongado, aumentando a eficiência dos processos de atomização. Aliado a isso, um procedimento simples no qual a amostra (100 mg) é misturada com HCl 0,1 mol/L foi proposto. Das análises dos alimentos, foram obtidos limites de detecção (LD) de 0,6; 100; 6,0 e 32 µg/L para Cd, Fe, Pb e Zn, respectivamente. Os desvios padrão relativos (RSD) para os elementos Cd (n = 14), Fe (n = 3) e Zn (n = 19) foram de 7,0; 5,5 e 6,0%, respectivamente. A freqüência analítica do método foi de 28 determinações por hora e a freqüência de amostragem, de 8 amostras por hora (desde o preparo de amostra até a determinação). Todas as determinações foram desenvolvidas com o uso de um mesmo tubo atomizador que, após 2270 determinações (cerca de 76 horas), não apresentou perdas de sensibilidade. Dessa forma, para o material certificado de referência de fígado bovino (SRM 1577b), os resultados para Cd e Zn foram adequados e as concentrações de Fe determinadas foram altamente dependentes do tamanho de partículas. Os metais tóxicos Cd e Pb não foram encontrados nas amostras estudadas de alimentos. Com relação aos elementos essenciais, não houve acréscimo de Fe e Zn ao alimento quando do uso do suplemento. Dessa forma, informações acerca da qualidade dos alimentos puderam ser obtidas, sendo o método proposto adequado para essa finalidade.
25

Aspectos analíticos em TS-FF-AAS: estudo de interferências e aplicação para a determinação de metais em vinhos e sucos / Analytical aspects of ts-ff-aas: study of interferences and application for determinations of metals in wines and grape juices

Schiavo, Daniela 28 February 2007 (has links)
Made available in DSpace on 2016-06-02T20:36:12Z (GMT). No. of bitstreams: 1 1928.pdf: 1029456 bytes, checksum: 9ad511e61da6289bd2135d247958af6b (MD5) Previous issue date: 2007-02-28 / Financiadora de Estudos e Projetos / In this work, it was evaluated the effects of interferences caused by major and minor constituents on Co, Cu and Mn atomized by flame atomic absorption spectrometry (FAAS) and by thermospray flame furnace atomic absorption spectrometry (TS-FFAAS). The main concomitants were chosen according to the typical concentrations found in foods and beverages. The liquid samples were propelled by a peristaltic pump through a ceramic capillary conductively heated by a flame and then into a nickel tube. The nickel tube was positioned on a lab-made stainless steel support with four ceramic pins on the flame burner. The thermospray was generated inside the heated ceramic capillary in contact with the nickel tube. The samples were introduced into the flame heated tube without the need of a nebulizer. Additionally, the sensitivity was significantly improved by increasing the residence time of the free analyte atoms in the observation zone. Severe interference effects were observed for all analytes. These interference processes require the application of either previous separation steps or special strategies of calibration. Afterwards, the applicability of TS-FF-AAS was evaluated for direct determination of Cu, Cd and Pb in wines and grape juices. The developed procedure did not require any step of digestion. The effect of ethanol was evaluated and samples were properly diluted before measurements. All determinations were carried out adopting optimized conditions and quantification was based on the standard additions method. Limits of detection (LOD) of 12.9, 1.7 and 5.32 µg L-1 (n = 14) for Cu, Cd and Pb, respectively, were obtained using optimized conditions for wine samples. Relative standard deviations (RSD, %) of 2.7, 2.1 and 2.6% for Cu, Cd and Pb were obtained (n = 6). Limits of detection (LOD) for grape juice samples were 13.7, 0.90 and 5.55 µg L-1 and relative standard deviations (RSD, %) of 3.3, 2.0 and 2.3 for Cu, Cd and Pb, respectively. The analytical throughput was 45 determinations h-1 and accuracy was proved by addition-recovery experiments. / Este trabalho de pesquisa avaliou o efeito de concomitantes em espectrometria de absorção atômica com chama (FAAS) e espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS) sobre a determinação de Co, Cu e Mn. Identificaram-se os principais concomitantes considerando-se os elementos tipicamente presentes em amostras de alimentos e de bebidas e os efeitos causados sobre os sinais analíticos desses analitos. Um aerossol térmico foi gerado em um capilar cerâmico aquecido condutivamente por contato com um tubo de níquel posicionado sobre a chama ar-acetileno. A solução das amostras foi introduzida no forno tubular sem a necessidade de um nebulizador. Além disso, a sensibilidade também foi melhorada pelo maior tempo de residência da nuvem atômica no interior do atomizador. O estudo evidenciou a ocorrência de severos efeitos de interferências para todos os analitos. Esses processos de interferências exigem a aplicação de procedimentos de separação ou estratégias especiais de calibração. Em seguida, a aplicabilidade da TS-FF-AAS foi avaliada para a determinação direta de Cu, Cd e Pb em amostras de vinhos e de sucos de uva. O efeito causado pelo etanol foi avaliado e as amostras foram diluídas previamente às medidas. O procedimento adotado não requer nenhum pré-tratamento da amostra. A partir das condições otimizadas e aplicando-se o método das adições de analito, o procedimento foi aplicado para amostras de vinhos do Brasil e do Chile e foram obtidos limites de detecção (LOD) de 12,9; 1,76 e 5,32 µg L-1 para Cu, Cd e Pb, respectivamente (n = 14). Os desvios padrão relativos (RSD, %) foram 2,7; 2,1 e 2,6 para Cu, Cd e Pb, respectivamente (n = 6). Os LOD´s para as amostras de sucos de uva foram 13,7; 0,90 e 5,55 µg L-1 e os desvios padrão relativo (RSD, %) foram 3,3; 2,0 e 2,3 para Cu, Cd e Pb, respectivamente (n = 6). O procedimento proposto se mostrou eficiente e possibilitou a determinação de Cu, Cd e Pb em baixas concentrações nas amostras de vinhos e sucos de uva. A freqüência foi 45 determinações h-1 e a exatidão foi comprovada por experimentos de adição e recuperação.
26

Determinação de molibdênio em plantas combinando microextração e espectrometria de absorção atômica em chama / Determination of molybdenum in plants combining microextraction and flame atomic absorption spectrometry

Villamizar, Jenny Andrea Oviedo 16 August 2012 (has links)
Made available in DSpace on 2016-06-02T20:36:41Z (GMT). No. of bitstreams: 1 4646.pdf: 1634842 bytes, checksum: 5f59a6fd3eedb7124e78f9dfa0fbcc6c (MD5) Previous issue date: 2012-08-16 / Universidade Federal de Sao Carlos / In this study, a procedure for the determination of low concentrations of molybdenum in plants by flame atomic absorption spectrometry (FAAS) was developed. The poor sensitivity of FAAS for determination of refractory elements such as molybdenum, and the typical low levels of this micronutrient in plants require the use of a preliminary preconcentration step. The procedure was based on the solidified floating organic drop microextraction strategy (SFODME). This method was selected based on its simplicity, high enrichment factors and low consumption of organic solvents. Because of SFODME microvolume characteristics, the effect of the discrete introduction of samples in FAAS was studied. The following extraction parameters were evaluated: type and concentration of complexing agent, type of solvent, solvent volume, use of ultrasound or vortex in the extraction process, and effect of discrete nebulization. All parameters were evaluated considering their effects on sensitivity for the determination of molybdenum in plant samples by FAAS. The most critical effects were caused by the type of complexing agent, the use of vortex mixing and discrete nebulization. Prior to the microextraction procedure, Mo complexing conditions were optimized. A 0.5% m v-1 8- hydroxyquinoline solution at pH 4.75 adjusted with acetate buffer and complexing time of 10 min were the ideal experimental conditions. For the microextraction procedure, the highest enhancement factor for Mo was obtained with 60 μL of 1-undecanol and using the vortex mixer for 2 min. Appreciable sensitivity improvements were observed by combining microextraction, the introduction of discrete volumes of sample, and determination of Mo by FAAS. An enrichment factor of 67, limit of detection of 4.9 μg L-1 and limit of quantification of 16.4 μg L-1 were reached. The accuracy of the developed procedure was demonstrated by determining Mo in certified reference materials. Finally, the procedure was applied to samples of roots and leaves of corn. / Neste trabalho foi desenvolvido um procedimento para a determinação de baixas concentrações de molibdênio em plantas utilizando a espectrometria de absorção atômica em chama (FAAS). A baixa sensibilidade típica de medidas em chama para elementos refratários e os baixos teores de molibdênio em plantas exigem uma etapa prévia de pré-concentração. O procedimento proposto foi baseado no método de microextração em gota orgânica solidificada. Esse método foi escolhido com base em sua simplicidade, o alto fator de enriquecimento que pode ser atingido e o baixo consumo de solvente extrator. Como o procedimento escolhido envolve microvolumes, foi estudado o efeito da introdução discreta de volumes no FAAS. Os seguintes parâmetros de extração foram investigados: tipo e concentração de agente complexante, tipo e volume de solvente, uso de ultrassom e vórtex no processo de extração e o efeito da nebulização discreta. Todos esses parâmetros foram avaliados considerando-se seus efeitos sobre a sensibilidade e os efeitos mais críticos foram observados para o tipo de agente complexante, uso de agitação por vórtex e uso da nebulização discreta. Previamente ao processo de microextração foram otimizadas as condições de complexação de Mo. Uma concentração de 0,5% m v-1 de 8- hidroxiquinolina, pH 4,75 ajustado com tampão acetato e um tempo de 10 min foram as condições ideais de complexação. No processo de microextração, o maior fator de enriquecimento foi obtido com 60 μL de 1-undecanol sob agitação com vórtex por 2 min. Ao combinar o processo de microextração com a introdução discreta de amostra no FAAS, observou-se uma melhora na sensibilidade. Um fator de enriquecimento máximo de 67, um limite de detecção de 4,9 μg L-1 e um limite de quantificação de 16,4 μg L-1 foram obtidos. A partir desses resultados, a exatidão foi demonstrada usando materiais de referência certificados e efetuou-se a determinação de Mo em amostras de raiz e folhas de milho.
27

Determinação de cobre, manganês e cádmio em por espectrometria de absorção atômica com forno de grafite / Determination of copper, manganese and cadmium in honey by graphite furnace atomic absorption spectrometry

Paes, Lorena Cristine, 1980- 19 October 2007 (has links)
Orientador: Solange Cadore / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-10T02:39:07Z (GMT). No. of bitstreams: 1 Paes_LorenaCristine_M.pdf: 387202 bytes, checksum: 46a0d9c60b50d24a3a34de8a99f50153 (MD5) Previous issue date: 2007 / Resumo: Visando o desenvolvimento de um método analítico para uma matriz heterogênea de interesse comercial e ambiental e, também, a fim de acrescentar novas informações sobre o mel nacional, este trabalho avaliou diferentes estratégias de tratamento do mel, diferentes modificadores químicos e otimizou os parâmetros instrumentais para a determinação de cobre, manganês e cádmio, por Espectrometria de Absorção Atômica com Forno de Grafite. O tratamento do mel com banho de ultrasom foi o procedimento mais adequado para o preparo da amostra, quando comparado às mineralizações em forno de microondas e em placa de aquecimento, bem como à solubilização com hidróxido de tetrametilamônio, devido à simplicidade e rapidez. Foi necessário o uso de peróxido de hidrogênio como modificador químico para aumentar a eficiência da eliminação da matriz nas determinações dos analitos de interesse, além do uso de 10 µg de Mg(NO3)2 como modificador químico para determinação de Mn e de 5µg de NH4H2PO4 como modificador químico para determinação de Cd. Os métodos otimizados apresentaram precisão, sensibilidade e repetibilidade adequadas e foram obtidas recuperações entre 70 e 90 %, o que indica uma exatidão satisfatória. As quantidades dos analitos nos méis brasileiros de diferentes procedências variaram entre 0,020 e 0,17 µg g de Cu, entre 0,39 e 11,9 µg g de Mn e foram menores que 6 ng g no caso do Cd. Observou-se que as amostras analisadas não são contaminadas com Cd e as altas concentrações de Mn confirmam que o mel brasileiro pode ser considerado uma boa fonte nutritiva deste elemento / Abstract: Different strategies for sample preparation, the optimization of instrumental parameters and the evaluation of different chemical modifiers for the determination of cadmium, copper and manganese in honey by graphite furnace atomic absorption spectrometry were developed. Honey is a heterogeneous matrix, which has great commercial and environmental importance. However, few studies concerning its mineral content have been carried out in Brazil. In this work the use of an ultra sonic bath was compared with digestion by microwave radiation or on a hot plate as well as solubilization with tetramethylammonium hydroxide. The best procedure for honey is that using ultrasound, considering its simplicity and speed of analysis. Hydrogen peroxide was used as chemical modifier together with 10 µg Mg(NO3)2 or 5 µg de NH4H2PO4 for the determination of Mn or copper, respectively. Satisfactory precision, sensitivity and accuracy as well as recoveries in the range of 70-90 % were obtained. Analyte concentrations in Brazilian honey, from different regions, varied between 0.020 to 0.17 µg g for Cu, and 0.3 to 11.9 for Mn. For Cd, values below 6 ng g were found. Brazilian honeys were not contaminated with Cd and may be considered a good source of manganese / Mestrado / Quimica Analitica / Mestre em Química
28

Avaliação de metais traço e de algumas características geoquímicas em sedimentos superficiais e testemunhos da Baía de Vitória, ES

Silva, Layla Bridi e 11 November 2010 (has links)
Made available in DSpace on 2016-12-23T14:41:53Z (GMT). No. of bitstreams: 1 LAYLA BRIDI E SILVA.pdf: 2599880 bytes, checksum: f245079791e40aba06fa8796f6a53fe1 (MD5) Previous issue date: 2010-11-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The estuaries are transitional environments between land and ocean, where human activities are intensively developed. The Estuarine System of Grande Vitória presents itself associated with urban areas and basins, predominantly agricultural and industrial activities, with various problems related to pollution and environmental contamination. The main objective of this study was to evaluate sediment samples collected in the estuarine system of Vitória Bay in the concentrations of trace metals and some geochemical characteristics. The variables were the contents of Al, As, Cd, Cr, Cu, Fe, Pb and Zn in surface sediment samples and sediment cores. There were two sampling campaigns, with 6 points for sampling surface sediments. For the sediment cores, just a campaign was conducted, and these were sampled in the middle of the channel of Victoria Bay through the technical of diving with sampler PVC pipe. All samples were centrifuged, dried and homogenized for subsequent digestion and metal analysis. The sediments were sieved for the fraction <63 &#61549; m obtained. For the opening of the samples we used a method adapted from USEPA 3050B. Analyses of metals were performed by GF-AAS and F-AAS, and certified by the reference material Mess-3. We also determined the levels of volatile organic matter (calcination at 550 ° C). Analysis of x-ray diffraction and radiometric dating with 210Pb were also performed in order to characterize the main minerals forming the sediment, and identify the sedimentation rate present in the Vitoria Bay. It was possible to classify the sediments as level 1 (low probability of effect on biota), except for arsenic, which is located between levels 1 and 2 (level 2 - probable adverse effect on biota), according the CONAMA 344. The testimony also showed levels of metals below the values permitted by law, and it was possible to observe a decrease in concentration of some metals and organic matter with depth. The main minerals identified in the samples were kaolinite, gibbsite, goethite, hematite, quartz and rutile. The sedimentation rate was calculated at 1.7 cm / year, and it was possible to correlate high levels of metals at times of creating districts of Grande Vitória / Os sistemas estuarinos são ambientes de transição entre o continente e o oceano, onde atividades humanas são intensivamente desenvolvidas. O Sistema Estuarino da Grande Vitória apresenta-se associado à áreas urbanas e bacias hidrográficas, onde predominam atividades agrícolas e industriais, apresentando diversos problemas relacionados à poluição e contaminação ambiental. O principal objetivo deste trabalho foi avaliar amostras de sedimentos coletadas no sistema estuarino da Baía de Vitória quanto à concentração de metais traço e algumas características geoquímicas. As variáveis analisadas foram os teores de Al, As, Cd, Cr, Cu, Fe, Pb e Zn em amostras de sedimentos superficiais e testemunhos. Foram realizadas duas campanhas amostrais, com 6 pontos de coleta de sedimentos de superfície. Para os testemunhos, apenas uma campanha foi realizada, e estes foram amostrados no meio do canal da Baía de Vitória, através da técnica de mergulho com cano de PVC. Todas as amostras foram centrifugadas, secadas e homogeneizadas, para posterior digestão e análise de metais. Os sedimentos superficiais foram peneirados, para que a fração < 63 &#61549;m fosse obtida. Para a abertura das amostras utilizou-se um método adaptado de USEPA 3050B. As análises de metais foram realizadas por GF-AAS e F-AAS, e certificadas com material de referência Mess-3. Também foram determinados os teores de matéria orgânica volátil (calcinação a 550°C). Análises de difração de raios-x e de datação radiométrica com 210Pb também foram realizadas, a fim de caracterizar os principais minerais que constituem o sedimento, e identificar a taxa de sedimentação à qual a Baía de Vitória está submetida. Foi possível classificar os sedimentos superficiais como sendo de nível 1 (baixa probabilidade de efeito na biota), exceto para arsênio, que se encontra entre os níveis 1 e 2 (nível 2 provável efeito adverso na biota), de acordo com CONAMA 344. Os testemunhos também apresentaram teores de metais abaixo dos valores permitidos por lei, e foi possível observar uma queda na concentração de alguns dos metais e da matéria orgânica com a profundidade. Os principais minerais identificados nas amostras foram caulinita, gibbsita, goethita, hematita, quartzo e rutilo. A taxa de sedimentação calculada foi de 1,7 cm/ano, e foi possível correlacionar altos teores de metais à épocas de criação de bairros da Grande Vitória
29

Determinação de elementos essenciais e contaminantes em amostras biológicas empregando espectrometria atômica

Santos, Luiz Raimundo Seneterri Silva Rodrigues dos January 2010 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-06T15:11:17Z No. of bitstreams: 1 DISSERTAÇÃO LUIZ RAIMUNDO S.S.R.SANTOS.pdf: 1266644 bytes, checksum: 450e692c86f2ffc5bc25ffa7e76b9e3d (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-06T15:37:29Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO LUIZ RAIMUNDO S.S.R.SANTOS.pdf: 1266644 bytes, checksum: 450e692c86f2ffc5bc25ffa7e76b9e3d (MD5) / Made available in DSpace on 2016-09-06T15:37:29Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO LUIZ RAIMUNDO S.S.R.SANTOS.pdf: 1266644 bytes, checksum: 450e692c86f2ffc5bc25ffa7e76b9e3d (MD5) / O estudo de elementos essenciais e contaminantes nas amostras biológicas é de grande importância visto que a variação da concentração destes é um parâmetro para detecção de diversas doenças e distúrbios metabólicos provocados pela exposição a substâncias tóxicas e medicamentos. O objetivo deste trabalho foi propor um método analítico visando avaliar o efeito da furosemida (diurético de alça) sobre a composição mineral (Mg, Cu, Fe, Se, Zn, Cd e Pb) em amostras biológicas (fígado, rim, coração, pulmão e soro) de ratos Wistar por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Para a decomposição das amostras foi utilizado um procedimento por via úmida, com adição de ácido nítrico e peróxido de hidrogênio, empregando forno de microondas com cavidade. As figuras analíticas de mérito (precisão, limites de detecção (LOD) e quantificação (LOQ) e efeito de matriz) foram determinadas para o procedimento proposto. A exatidão foi verificada com material de referência certificado fígado bovino NIST 1577b e por comparação com método de referência da AOAC (Association of Official Analytical Chemists). O procedimento proposto foi aplicado para avaliação dos efeitos da furosemida sobre a composição corporal de elementos essenciais e contaminantes de ratos Wistar. Os dados para Se, Cd e Pb foram abaixo do LOQ, sendo necessário a utilização de técnicas mais sensíveis como GF AAS e ICP-MS para a quantificação desses elementos em amostras biológicas. Em relação ao comportamento dos minerais nas amostras biológicas estudadas, o Cu, nas amostras biológicas dos ratos machos, este apresenta uma redução no fígado, rim e coração, mantendo-se constante no pulmão. Nas fêmeas há um aumento no fígado e redução no rim, coração e pulmão. Para o Fe, o comportamento é semelhante entre machos e fêmeas, com redução no fígado, rim e soro e aumento no coração e pulmão. O Mg apresenta uma constância no fígado e pulmão, redução no rim, coração e aumento no soro para machos, enquanto para fêmeas, em fígado e rim permanecem constantes e há redução no coração, pulmão e soro. Já o Zn reduz no fígado e rim dos machos e se mantém constante no coração e pulmão, sendo o inverso para as fêmeas. Foi encontrando como resultados uma extração dos elementos Mg, Cu e Zn em todos os tecidos biológicos estudados em uma magnitude de 16,8; 15,1 e 6,4 % para ratos machos e 13,0; 16,5 e 8,1 % para fêmeas, após a administração da furosemida em todos os animais estudados. O Fe apresentou um aumento de 21,8% e 5,1%, em todos os tecidos biológicos estudados, para ratos machos e fêmeas respectivamente, concluindo que a furosemida não traz prejuízos para a saúde com relação à perda de elementos essenciais / The study of essential elements and contaminants in biological samples is of great importance since the variation of the concentration of these is a parameter for the detection of various diseases and metabolic disorders caused by exposure to toxic substances and medicines. The aim of this study was to propose an analytical method to evaluate the effect of furosemide (loop diuretic) on the mineral composition (Mg, Cu, Fe, Se, Zn, Cd and Pb) in biological samples (liver, kidney, heart, lung and serum) of rats by optical emission spectrometry with inductively coupled plasma (ICP OES). For decomposition of the samples we used a procedure by wet, with the addition of nitric acid and hydrogen peroxide, using a microwave cavity. The analytical figures of merit (precision, limit of detection (LOD) and quantification (LOQ) and matrix effect) were determined for the proposed procedure. The accuracy was checked with certified reference material NIST 1577b bovine liver and by comparison with reference method AOAC (Association of Official Analytical Chemists). The proposed procedure was applied to assess the effects of furosemide on body composition of essential elements and contaminants in rats. The data for Se, Cd and Pb were below the LOQ, necessitating the use of more sensitive techniques such as GF AAS and ICP-MS for quantification of these elements in biological samples. As for the behavior of minerals in biological samples studied, the Cu in biological samples from male rats, this presents a reduction in the liver, kidney and heart, remaining constant in the lung. In females there is an increase in the liver and reduction in kidney, heart and lung. For Fe, the behavior is similar between males and females, with a reduction in the liver, kidney and serum and increased heart and lung. Magnesium has a constancy in the liver and lung, reduction in kidney, heart and an increase in serum for males as for females, liver and kidney remain constant and there is a reduction in heart, lung and serum. Already reduces the Zn in the liver and kidney of males and remained constant in the heart and lungs, and the converse for females. Was found as a result of the extraction elements Mg, Cu and Zn in all biological tissues studied in a magnitude of 16.8, 15.1 and 6.4% for males and 13.0, 16.5 and 8.1 % for females, after administration of furosemide in all animals studied. Fe showed an increase of 21.8% and 5.1% in all biological tissues studied, for males and females respectively, concluding that furosemide does not bring harm to health in relation to loss of essential elements
30

Sílica mesoporosa como suporte sólido para o ancoramento da molécula 4-amino-3-hidrazino-5-mercapto-1,2,4-triazole e aplicação na adsorção de Cu(II), Cd(II), Ni(II), Pb(II) e Co(II) em amostras aquosas / Mesoporous silica as the solid support for the anchoring of 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole molecule and application in the adsorption of Cu (II), Cd (II), Ni (II), Pb (II) and Co (II) in aqueous samples

Ivassechen, Janaíne do Rocio [UNESP] 07 January 2016 (has links)
Submitted by JANAINE DO ROCIO IVASSECHEN null (janaine_jri@yahoo.com.br) on 2016-02-23T23:37:58Z No. of bitstreams: 1 dissertação Janaíne.pdf: 2608394 bytes, checksum: 89d6d43b306c92a291cb379448dd11de (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-02-24T14:58:59Z (GMT) No. of bitstreams: 1 ivassechen_jr_me_araiq.pdf: 2608394 bytes, checksum: 89d6d43b306c92a291cb379448dd11de (MD5) / Made available in DSpace on 2016-02-24T14:58:59Z (GMT). No. of bitstreams: 1 ivassechen_jr_me_araiq.pdf: 2608394 bytes, checksum: 89d6d43b306c92a291cb379448dd11de (MD5) Previous issue date: 2016-01-07 / A determinação direta de metais presentes em baixas concentrações em amostras de águas naturais é geralmente dificultada devido à presença de espécies interferentes. Os metais que foram estudados, Cu (II), Pb(II), Co (II), Ni (II) e Cd (II) são de interesse ambiental em razão de seu uso intensivo, distribuição e por serem absolutamente não-degradáveis podem acumular-se em matrizes ambientais manifestando toxicidade. Neste projeto desenvolveu-se a sílica como suporte sólido para o ancoramento da molécula 4-amino-3-hidrazino-5-mercapto-1,2,4-triazole e sua aplicação na adsorção/remoção de íons em solução aquosa. O material foi caracterizado por espectroscopia na região do infravermelho (FTIR), o qual apresentou bandas em 1690- 1649 e 790 cm-1 , característica de ligações N-H de aminas primárias do ligante. A ressonância magnética nuclear de 13C e 29Si (RMN) comprovam o ancoramento do ligante. As medidas de área de superfície específica pelo método de BET e diâmetro de poro resultaram em uma área de 795,51 ± 1,14 m2 g-1 e poros numa gama de 1,1 a 7,1 nm. A Microscopia Eletrônica de Varredura (MEV) mostrou que o material tem formato esférico com tamanhos aproximadamente de 10 μm e a Análise por Energia Dispersiva de Raios X (EDX) mostrou uma distribuição homogênea do sililante por toda a superfície do material. Com isso, confirmou-se a ocorrência da reação de modificação. O material foi aplicado em estudos de adsorção para determinação da sua capacidade máxima, bem como estudos da influência do pH e estudos cinéticos no processo de equilíbrio Os experimentos foram realizados pelo método de batelada. O primeiro teste foi o pHPZC, que indica a melhor faixa de pH (5-9) para a adsorção. Os estudos de adsorção dos metais em solução apresentaram o melhor resultado quando o pH era igual a 6, o equilíbrio de adsorção foi atingido depois de 50 minutos de agitação. Para todas as espécies investigadas o processo de adsorção é melhor descrito pelo modelo de pseudo- segunda ordem. Com esses parâmetros estabelecidos os valores de capacidade máxima de adsorção foram encontrados, sendo 0,129; 0,102; 0,105; 0,113; e 0,076 mmol g-1 para o Cu, Ni, Pb, Co e Cd, respectivamente. A sílica modificada foi aplicada na pré-concentração de Cu (II) em amostras aquosas. Com um fator de enriquecimento de 20 vezes, a coluna provou ser estável ao longo de 24 ciclos de adsorção/dessorção. / The direct determination of metals present at trace levels in natural water samples is generally difficult due to the presence of interfering species. Metals that were studied, Cu(II), Pb(II), Co(II), Ni(II) and Cd(II) are of environmental interest because of its intensive use, distribution, and as a consequence of its non-degradability can be accumulated in environmental matrices manifesting toxicity. In this project was developed a mesoporous silica as solid support for the anchoring of 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole molecule to be applied in the adsorption/removal of metals from aqueous solution. The material was characterized by infrared spectroscopy (FTIR), which showed bands at 1649 and 1690- 790 cm-1, characteristic of NH bonds of primary amines, existing in molecule ligand. The nuclear magnetic resonance 13C and 29Si (NMR) confirm the anchoring of the ligand. Measurements of specific surface area by the BET method and pore diameter resulted in an area of 795.51 ± 1.14 m2 g-1 and pores in a range from 1.1 to 7.1 nm. Scanning Electron Microscopy (SEM) showed that the material has spherical shape with sizes of approximately 10 μm and the analysis by Energy Dispersive X-ray (EDX) showed a homogeneous distribution of silylant over material surface. Thus, it was confirmed the occurrence of the modification reaction. The material was applied in adsorption studies to determine its maximum adsorption capacity, as well as studies of the influence of pH and kinetic studies on the balance process. The experiments were performed by the batch method. The first test was the pHPZC which indicates the best pH range (5-9) for the adsorption. Adsorption studies showed the best results when pH was near 6 and the adsorption equilibrium was attained after 50 minutes of stirring time. For all species investigated the adsorption process is better described by the pseudo- second order kinetic model. With these parameters established the maximum adsorption capacity values found were 0.129, 0.102, 0.105, 0.113 and 0.076 mmol g-1 for Cu(II), Ni(II), Pb(II), Co(II) and Cd(II), respectively. Modified silica was also applied in the preconcentration of Cu(II) from aqueous samples with 20 fold enrichment factor and the packed column proved to be stable over 24 cycles of adsorption/desorption.

Page generated in 0.5315 seconds