• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 28
  • 16
  • 7
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 152
  • 152
  • 58
  • 48
  • 27
  • 23
  • 22
  • 19
  • 19
  • 19
  • 18
  • 17
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Resistência à flexão, sorção, solubilidade e estabilidade de cor de compósitos odontológicos reforçados por fibras / Flexural strength, water sorption, solubility and color stability of some fiber reinforced composite

Medeiros, Renata Souza 10 August 2012 (has links)
Os objetivos deste estudo foram: 1) avaliar a resistência à flexão em três pontos de um compósito para uso direto (Filtek Z350 XT, 3M ESPE) e um para uso indireto (Signum, Heraeus, Kulzer) reforçados por uma ou duas camadas de fibras de polietileno (Ribbond -THM, Ribbond®) ou de vidro (Interlig, Ângelus) tratados termicamente (170°C por 10 minutos), comparados com os grupos controle (não reforçados por fibras e/ou não tratados termicamente; 2) avaliar a sorção, a solubilidade e a estabilidade de cor dos compósitos reforçados, após armazenamento em água destilada à 37°C por 14 dias. A estabilidade de cor foi avaliada com auxílio de um espectrofotômetro de contato dental (Vita EasyShade, Vident, CA, USA). Para o ensaio de resistência à flexão, foram confeccionados espécimes retangulares com dimensões de 12 x 2 x 2mm (n=10), com os seguintes fatores de variação: a) compósito (para uso direto ou indireto); b) tipo e número de camadas de fibras (vidro ou polietileno/uma ou duas camadas); c) submetidos ou não a tratamento térmico. O tratamento térmico foi realizado 24 horas após fotoativação em estufa à temperatura de 170°C por 10 minutos. O ensaio foi realizado 24 horas após fotoativação ou tratamento térmico. Para avaliação de sorção/solubilidade e estabilidade de cor, foram confeccionados espécimes em forma de disco com dimensões de 15 x 2mm (n=5), em que foram analisados os seguinte fatores: a) compósito (para uso direto ou indireto); b) tipo de fibra (vidro ou polietileno); c) número de camadas de fibras (uma ou duas). Foi realizada análise dos parâmetros de cor antes e após imersão em água deionizada por 14 dias. Os resultados foram analisados por ANOVA e teste de contraste de Tukey, com nível de significância de 5% e revelaram que a fibra de vidro, quando utilizada em duas camadas, propiciou os maiores valores de resistência à flexão para os dois compósitos testados (165,4 MPa Z350XT e 208,7MPa Signum ). O tratamento térmico não apresentou significância estatística quanto à resistência à flexão do compósito direto. Para o compósito para uso indireto (Signum ) foi encontrada diferença estatisticamente significante para o fator tratamento térmico, que indicou valores de resistência à flexão inferiores para os grupos tratados termicamente. O compósito para uso direto apresentou valor de sorção superior (33,6/cm3) ao do compósito para uso indireto (19,1/cm3). Para solubilidade, foi encontrada interação para os fatores compósito e tipo de fibra, indicando maiores valores para o compósito para uso direto associado à fibra de vidro. A análise de alteração de cor demonstrou maior valor de E para a fibra de polietileno (E =1,5) quando comparado à fibra de vidro (E=1,0). Concluiu-se que: 1) a adição de fibras propicia aumento dos valores de resistência à flexão de compósitos para uso direto e indireto, o aumento da resistência foi observado quando do uso de duas camadas de fibras; 2) o tratamento térmico à 170°C por 10 minutos não indicou melhora nas propriedades mecânicas dos compósitos reforçados; 3) adicionar fibras aos compósitos não aumentou os valores de sorção/solubilidade quando imersos em água; 4) Imersão em água não produziu alterações de cor relevantes para os compósitos reforçados com fibras se comparados aos sem fibras. / The aims of this study were: 1) to evaluate the flexural strength of one composite for direct use (Filtek Z350 XT, 3M ESPE) and one for indirect use (Signum, Heraeus, Kulzer) as a function of the reinforcement by one or two layers of polyethylene (THM-Ribbond, Ribbond ®) or glass fibers (Interlig, Angelus) submitted to heat treatment (170°C for 10 minutes) compared with control groups (not reinforced by fibers and/or not heat-treated; 2) evaluate water sorption, solubility and color stability of the reinforced composites, after storage in distilled water at 37°C for 14 days. Color stability was evaluated using a spectrophotometer (Vita Easyshade, Vident, CA, USA). For three point flexural bending test, rectangular specimens were prepared with dimensions of 12 x 2 x 2 mm (n=10), according to the following variation factors: a) composite (for direct or indirect use); b) type of fibers and number of layers (glass or polyethylene/one or two layers; c) subjected or not to heat treatment. The heat treatment was performed 24 hours after curing, in a furnace, at 170 ° C for 10 minutes. Tests were performed 24 hours after curing or heat treatment. To evaluate the water sorption/solubility and color stability, disc-shaped specimens were prepared with dimensions of 15 x 2 mm (n=5) according to the following variation factors: a) composite (for direct or indirect uses); b) fiber type (glass or polyethylene); c) number of fiber layers (one or two). Color parameters were analyze before and after immersion in deionized water for 14 days. The results were analyzed by ANOVA and Tukeys test with significance level of 5%, and indicated that the glass fiber when used in two layers, showed the highest flexural strength for the two tested composites (165.4 MPa - Z350XT and 208.7 MPa - Signum ). The heat treatment did not significantly affect the flexural strength of the direct composite. For the composite for indirect use (Signum ), a statistical significance for the factor heat treatment was found, indicating lower values of flexural strength for heat-treated groups. The composite for direct use showed higher water sorption value (33.6 /cm3) when compared to the composite for indirect use (19.1 /cm3). For solubility, a significant interaction was found for composite and fiber type, indicating higher values for direct composite and glass fiber. Color stability analysis showed higher color difference value for polyethylene fiber (E =1.5) when compared to glass fiber (E=1.0). It was concluded that: a) adding fibers increased the flexural strength values of the composites for direct or indirect use, the increase in strength was more pronounced when using two fiber layers; 2) heat treatment at 170 ° C for 10 minutes showed no improvement of the mechanical properties of fiber reinforced composites; 3) adding fibers to the composite did not increase the sorption/solubility after water immersion, 4) Immersion in water did not change the color of the fiber reinforced composites when compared with those without fibers.
92

Comportamento de fadiga e perfis de tensões residuais de cerâmicas odontológicas / Fatigue behavior and residual stress profiles of dental ceramics

Fukushima, Karen Akemi 02 March 2015 (has links)
Capítulo 1. Objetivos: Medir e comparar o perfil de tensão residual da cerâmica de recobrimento aplicada sobre infraestruturas em zircônia tetragonal policristalina estabilizada por ítria (Y-TZP), em um compósito de alumina/zircônia (ZTA) e em uma alumina policristalina (AL). Material e Métodos: Os perfis de tensão residual de cada um dos materiais foi medido por meio do método \"hole-drilling\" em discos de 19 mm de diâmetro e 2,2 mm de espessura (0,7 mm de infraestrutura + 1,5 mm de porcelana de cobertura) .Resultados: Os espécimes de AL exibiram tensões de compressão que aumentaram numericamente com a profundidade, enquanto que as tensões compressivas mudaram para tensões de tração no interior das amostras de Y-TZP. As amostras de ZTA exibiram tensões de compressão na superfície, decrescendo com a profundidade até 0,6 mm, tornando-se compressivas novamente próximo à infraestrutura. Conclusão: O ZTA não apresentou tensões de tração em nenhum ponto ao longo da espessura da cerâmica de recobrimento. A AL apresentou um perfil de tensão residual mais favorável, gerado pelas tensões compressivas. A Y-TZP apresentou o perfil mais desfavorável, por apresentar tensões de tração próximo à infraestrutura. Capítulo 2. Objetivos: 1) Comparar os coeficientes de susceptibilidade ao crescimento subcrítico (n), de uma zircônia tetragonal policristalina estabilizada por ítria, obtidos por meio de dois ensaios de fadiga: cíclica e dinâmica. 2) Verificar o efeito da frequência usada no ensaio de fadiga cíclica no tempo de vida característico. Material e Métodos: Espécimes em forma de barras (25 mm x 4 mm x 3 mm) foram confeccionadas de acordo com as recomendações do fabricante. Os ensaios de fadiga dinâmica (n=70) e de fadiga cíclica (n=75) foram realizados por meio de resistência à flexão em quatro pontos para a obtenção dos parâmetros de crescimento de trincas subcrítico (SCG). O ensaio de fadiga cíclica também foi realizado em duas frequências (2 e 10 Hz), utilizando valores de tensão máxima entre 350 e 600 MPa. Todos os espécimes fraturados foram inspecionados em microscópio eletrônico de varredura para que fosse identificada a origem da fratura. Os dados de fadiga dinâmica foram analisados por meio das fórmulas apresentadas na ASTM C 1368-00. Os dados de fadiga cíclica foram analisados por meio da estatística de Weibull e por meio de análise tipo \"General Log Linear Model\". Resultados: A Y-TZP apresentou valores dos parâmetros de SCG obtidos no ensaio de fadiga dinâmica de ?fo = 667 MPa e n = 54. Os parâmetros de Weibull obtidos a partir dos resultados do mesmo ensaio foram de m = 7,9, ?0 = 968,9 MPa e ?5% = 767 MPa. Os parâmetros de Weibull obtidos no ensaio de fadiga cíclica foram estatisticamente semelhantes para as duas frequências utilizadas, o m* foi de 0,17 para 2Hz e de 0,21 10Hz; os tempos de vida característicos (?, em número de ciclos) foram de 1,93 x 106 e 40.768, respectivamente para 2 e 10 Hz. O valor de n obtido na fadiga cíclica foi de 48 e 40, nas frequências de 2 e 10 Hz, respectivamente. Não foi observado o efeito da frequência da aplicação da tensão, do nível de tensão, nem da interação dos dois no tempo de vida da Y-TZP, quando analisados pelo General Log Linear Model. Conclusão: Os coeficientes de susceptibilidade ao crescimento subcrítico (n) obtidos por meio de fadiga cíclica e dinâmica foram semelhantes para a Y-TZP testada. Os extensos intervalos de confiança obtidos nos ensaios de fadiga cíclica indicaram não haver efeito da frequência usado nesse método de fadiga nos tempos de vida característicos da Y-TZP testada. / Chapter 1. Objective: was: to measure and compare the residual stress profile in the veneering ceramic layered on three different polycrystalline ceramic frame-work materials: Y-TZP, alumina polycrystalline (AL) and zirconia toughened alumina (ZTA).Materials and Methods. The stress profile was measured with the hole-drilling method in bilayered disk samples of 19 mm diameter with a 0.7 mm thick Y-TZP, AL or ZTA framework and a 1.5 mm thick layer of the corresponding veneering ceramic. Results: The AL samples exhibited increasing compressive stresses with depth, while compressive stresses switching into interior tensile stresses were measured in Y-TZP samples. ZTA samples exhibited compressive stress at the ceramic surface, decreasing with depth up to 0.6 mm from the surface, and then becoming compressive again near the framework. Conclusions: Y-TZP samples exhibited a less favorable stress profile than those of AL and ZTA samples. Chapter 2. Objectives: 1) To compare the stress corrosion coefficient (n) of a Y-TZP, obtained by two fatigue tests: cyclic and dynamic and 2) Evaluate the effect of frequency used in the cyclic fatigue test in the characteristic lifetime. Methods: Bar shaped specimens (4 mm x 25 mm x 3 mm) were prepared according to the manufacturer\'s recommendations. The dynamic fatigue test (n = 70) and cyclic fatigue (n = 75) were performed by four-point bending to obtain the slow crack growth parameters (n) .The cyclic fatigue test was also conducted in two frequencies (2 and 10Hz), using stress levels between 350 and 600 MPa. All fractured specimens were inspected by SEM so that the origin of the fracture were identified. The dynamic fatigue data were analyzed using the formulas given in ASTM C 1368-00. Cyclic fatigue data were analyzed using Weibull statistics and by the Log General Linear Model. Results: The material showed values of parameters obtained in the SCG assay dynamic fatigue ?fo = 667 and n = 54. The Weibull parameters obtained from the same test results were m = 7.9, ?0 = 968, 9 and ?5% = 767. The Weibull parameters obtained by cyclic fatigue were statistically similar for the two frequencies used, the m* was 0.17 (2 Hz) and 0.21 (10 Hz); characteristic lifetimes (?) were 1.93 x 106 and 40768, respectively. The n value obtained by cyclic fatigue was 48 and 40 at frequencies of 2 and 10 Hz, respectively. There was no effect of the frequency, the stress level or the interaction of the two in the Y-TZP lifetime, when analyzed by General Log Linear Model. Conclusion: The n values obtained by cyclic and dynamic fatigue tests were similar to Y-TZP tested. The extensive confidence intervals obtained in cyclic fatigue tests showed no effect of frequency used this method in fatigue characteristic lifetimes of the Y-TZP tested.
93

Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splints

Soares, Rodrigo Gonçalves 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
94

Efeito da troca iônica nos parâmetros de Weibull, de crescimento subcrítico de trincas e no comportamento de curva R de uma porcelana odontológica / Efffect of ion exchange on Weibull and slow crack growth parameters and R-curve behavior of a dental porcelain

Rosa, Vinicius 06 July 2007 (has links)
O objetivo deste estudo foi avaliar o efeito da temperatura de troca iônica (TI) nas propriedades mecânicas da porcelana Ultrapaline ST e o efeito da TI nos parâmetros de crescimento subcrítico de trincas (SCG) (coeficiente de SCG - n, parâmetro escalar - ?f0), de Weibull (resistência característica - ?0, módulo de Weibull - m) e no comportamento de curva R desta porcelana. 250 discos (12 mm diâmetro x 1 mm espessura) foram fabricados de acordo com as instruções do fabricante, usinados em retificadora plana e polidos até 1 ?m. Para determinar o efeito da temperatura de TI na resistência à flexão biaxial (?), dureza (H) e tenacidade à fratura (KIc), 40 discos foram divididos em 4 grupos (n=10): GI (controle) - sem TI; e GII, GIII e GIV submetidos a TI com KNO3 por 15 min a 450°C; 470°C e 490°C, respectivamente. A ? foi determinada por \"pistão sobre três esferas\" em saliva artificial a 37°C a 10 MPa/s. Para dureza e tenacidade à fratura, foram feitas 3 indentações Vickers em cada espécime (2kg, 30s) e as diagonais e trincas radiais foram medidas e os valores de H e KIc calculados. As médias e desvios-padrão para ? (MPa), H (GPa) e KIc (MPa.m1/2) foram: GI: 57,95 ± 8.97, 7,24 ± 0,79 e 1,14 ± 0,14; GII: 125,04 ± 23,58, 5,80 ± 0,14, 2,62 ± 0,14; GIII: 133,00 ± 11,00, 5,88 ± 0,45, 2,54 ± 0,22; GIV: 137,67 ± 12,05, 5,88 ± 0,17, 2,57 ± 0,10, respectivamente. Para determinação dos parâmetros de SCG e de Weibull, 140 espécimes foram divididos em 2 grupos: GC (controle) e GT (submetidos à TI por 15 min a 470°C). Para determinação de n e de ?f0, 50 espécimes de cada grupo foram testados em saliva artificial a 37°C em flexão biaxial em uma das seguintes taxas de tensão: 10-2, 10-1, 100, 101 e 102 MPa/s. Para determinação dos parâmetros de Weibull, mais 20 espécimes de cada grupo foram ensaiados na taxa de 100 MPa/s. Os valores de n, ?f0, m e ?0 foram, respectivamente (valores entre parênteses representam intervalos de confiança de 95%): 24,1 ± 2,5; 58,1 ± 0,01; 13,8 (10,0 a 18,8) e 60,4 (62,2 a 58,5) para GC e 36,7 ± 7,3; 127,9 ± 0,01; 7,4 (5,3 a 10,1) e 136,8 (129,1 a 144,7) para GT. Para determinação do efeito da TI no curva R, 7 espécimes de cada grupo receberam uma indentação Vickers em uma das seguintes cargas de indentação (kg): 0,18; 0,32; 0,56; 1,0; 3,2. Após armazenados ao ar por 24 h os espécimes foram ensaiados a 10 MPa/s em saliva artificial a 37°C. Os parâmetros ?, ?, q foram, respectivamente: 62,57; 0,12 e 0,2857 para GC e 161,50; 0,34 e -0,0074 para GT. Os valores de k variaram de 0,371 a 0,515 para GC e de 1,240 a 0,804 para GT. Não houve diferença nas propriedades mecânicas entre as três temperaturas de TI testadas. A TI promoveu aumento significativo do valor de n, ?f0 e ?0, entretanto resultou em diminuição do valor de m e também suprimiu o comportamento de curva R, presente no material antes da realização da TI. / The objectives of this study were to determine the influence of different ion exchange (IE) temperatures on mechanical properties of a dental porcelain Ultrapaline ST and the effect of IE on slow crack growth (SCG) (coefficient of SCG - n, scale parameter - ?f0) and Weibull parameters (characteristic strength - ?0; Weibull modulus - m) and R-curve behavior of this porcelain. 250 specimens (12 mm diameter x 1 mm height) were fabricated according to the manufacturer\'s instructions, grounded with a surface-grinding device and polished up to 1?m. To determine the effect of IE temperature on biaxial flexural strength (?), hardness (H) and fracture toughness (KIc), 40 specimens were divided in four groups (n=10) as follow: GI - control (no ion exchange); GII, GIII and GIV submitted to IE with KNO3 for 15 min at 450°C; 470°C e 490°C, respectively. The ? was determined using a piston-on-three-balls device, in artificial saliva at 37°C and constant loading rate of 10 MPa/s. For hardness and fracture toughness, 3 Vickers indentations (2kg, 30s) were made on each specimen. The diagonals and radial cracks were measured in order to calculate H and KIc. Mean and standard deviations values of ? (MPa), H (GPa) and KIc (MPa.m1/2) were: I: 57.95 ± 8.97; 7.24 ± 0.79; 1.14 ± 0.14; II: 125.04 ± 23.58; 5.80 ± 0.14; 2.62 ± 0.14; III: 133.00 ± 11.00; 5.88 ± 0.45; 2.54 ± 0.22; IV: 137.67 ± 12.05; 5.88 ± 0.17; 2.57 ± 0.10, respectively. To determine the effect of IE on SCG and Weibull parameters, 140 specimens were divided in 2 groups: GC (control) and GIE (submitted to IE at 470°C for 15 min). To determine the SCG parameters, 10 specimens of each group were tested in biaxial flexural strength in each one of five constant stress rates: 10-2, 10-1, 100, 101 e 102 MPa/s. To determine the Weibull parameters, 20 specimens of each group were tested in the stress rate of 100 MPa/s. The n, ?f0, m and ?0 (values in parenthesis represent the confidence interval) were: 24.1 ± 2.5; 58.1 ± 0.01; 13.8 (10.0 to 18.8) and 60.4 (62.2 to 58.5) for GC and: 36.7 ± 7.3; 127.9 ± 0.01; 7.4 (5.3 to 10.1) and 136.8 (129.1 to 144.7) for GIE, respectively. To determine the effect of IE on R-curve behavior, 7 specimens of each group received a Vickers indentation in one of the following indentation loads (kg): 0.18; 0.32; 0.56; 1.0; 3.2. After stored on air for 24 h, the specimens were tested biaxial flexure strength in artificial saliva at 37°C in a stress rate of 10 MPa/s. The ?, ?, q parameters were, respectively: 62.57; 0.12 and 0.2857 for GC and 161.50; 0.34 and -0.0074 for GIE. The values of k varied from 0.371 to 0.515 for GC and from 0.34 to 0.0074 for GIE. There are no differences on mechanical properties among the three IE temperatures tested. The IE promoted significantly increase of n, ?f0 and ?0 however, decreased the m value and suppressed the R-curve behavior originally present on material before the IE.
95

Polimerização com laser de argônio: influência na tensão de contração, microdureza, resistência flexural e módulo de elasticidade de uma resina composta / Polymerization with the argon laser: Influence on shrinkage stress microhardness, percentage of maximum hardness, flexural strength and flexural modulus of a composite resin

Delfino, Carina Sinclér 19 September 2008 (has links)
O objetivo desse estudo foi verificar a influência da fotoativação com laser de argônio na tensão de contração (TC), microdureza (M), porcentagem de dureza máxima (PDM), resistência flexural (RF) e módulo de elasticidade (ME) de uma resina composta híbrida. A fotoativação foi realizada com laser de argônio 200mW por 10 segundos (L1), 200mW por 20 segundos (L2), 250mW por 10 segundos (L3) e 250mW por 20 segundos (L4). Como controle foi utilizada a luz hálógena por 20 segundos (H). A TC foi monitorada por 5 minutos em corpos-de-prova com 5mm de diâmetro e 1mm de altura. A M e a PDM foram obtidas em corpos-de-prova com 2mm de espessura após 7 dias a 37°C. Para obtenção da RF e do ME foram confeccionados corpos-de-prova nas dimensões 10 X 2 X 1mm (comprimento, largura e espessura), testados após 24h a 37°C. Os dados obtidos foram analisados por ANOVA/Teste de Tukey (p<0,05). Os valores de TC (MPa) foram estatisticamente mais baixos para o grupo L3 (1,3)c, seguido pelos grupos L1(2,7)b, L4 (3,4)a,b, L2 (3,7)a e H (4,5)a. Para os valores de M não houve diferença estatisticamente significante quando o mesmo tempo de fotoativação foi utilizado, sendo L1= 70,1a, L2= 78,1b, L3= 69,9a, L4= 78,1b e H= 79,9b. Todos os grupos apresentaram uma PDM de no mínimo 80%. Apenas o grupo L1 apresentou diferença estatisticamente significante na RF (MPa) e no ME (GPa), 86,2 e 5,4 respectivamente, sendo inferior. Dentro dos grupos estudados, o L3 apresentou propriedades mecânicas adequadas e mínima tensão de contração, além de possibilitar redução do tempo clínico para fotoativação de restaurações com a resina testada em 50%. / The objective of this study was to verify the influence of photoactivation with the argon ion laser on shrinkage stress (SS), followed by evaluation of Vickers microhardness (VM), percentage of maximum hardness (PMH), flexural strength (FS) and flexural modulus (FM) of a composite resin. Methods: The light curing units used were argon ion laser and halogen light. The groups were: L1- laser at 200mW for 10 seconds; L2- laser at 200mW for 20 seconds; L3- laser at 250mW for 10 seconds; L4- laser at 250mW for 20 seconds; and H- halogen light at 275mW for 20 seconds. The SS was monitored for 5 minutes in samples 5-mm in diameter by 1-mm in height. The VM and PHM were obtained in samples with a thickness of 2-mm after 7 days at 37°C. To FS and FM the samples were prepared using a stainless steel mold 10 x 2 x 1mm (length, width and height) and measured after 24h storage at 37°C. Data were analyzed by ANOVA/Tukey`s test (p<0.05). Results: The values of SS (MPa) were statistically lower for the group L3(1.3)c, followed by groups L1(2.7)b, L4 (3.4)a,b, L2(3.7)a and H(4.5)a. To the values of VM there was no difference when the same time of photo activation was used, being L1= 70.1a, L2=78.1b, L3= 69.9a, L4= 78.1b and H= 79.9b. All groups showed a PMH of at least 80%. Only the group L1 showed difference in FS (MPa) and FM (GPa), 86.2 and 5.4 respectively, being lower. Conclusion: within the studied groups, the L3 group presented adequate mechanical properties and minimum SS, reducing the clinical working time for photo activation of restorations with the tested resin in 50%.
96

EFEITO DA FRAÇÃO CRISTALINA E TAMANHO DE CRISTAL NA RESISTÊNCIA MECÂNICA E TENACIDADE À FRATURA DA VITROCERÂMICA DISSILICATO DE LÍTIO

Senk, Mariza Veiga 23 February 2017 (has links)
Made available in DSpace on 2017-07-21T19:25:55Z (GMT). No. of bitstreams: 1 Mariza Veiga Senk.pdf: 2040770 bytes, checksum: 1ff48305b56e9836d0e4d55aeae4277f (MD5) Previous issue date: 2017-02-23 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / Glass-ceramic are obtained from the controlled crystallization of glasses and may exhibit different characteristics of the precursor glass. In this work we investigate the variation of the flexural strength and fracture toughness those were obtained by lithium disilicate glass-ceramic materials as a function of the size of the precipitate and the crystalline volumetric fractions, obtained by mechanical tests balls on three balls and flexion of four points, respectively. The temperatures used in the heat treatments were 460 ° C for nucleation and 538 ° C for crystalline growth. The mechanical properties of the glass ceramics varied in relation to the crystalline fraction. The flexural strength of the glassy sample was 117 11 MPa and for the samples with crystalline fraction of 98 % and precipitate with a diameter of 7 m was 297 22 MPa. The fracture toughness in lithium disilicate increases with the crystallized volumetric fraction, and the larger the grain size, the greater the value of KIC. The fracture toughness for the glass sample showed a value of 0,80 0,09 MPa:m0;5 and for the crystal of 34 and fraction of 80 %, KIC= 3,05 0,2 MPa:m0;5, an increase of 280 % on the glass. / Vitrocerâmicas são obtidas a partir da cristalização controlada de vidros e podem apresentar características diferentes do vidro precursor. Neste trabalho são investigadas a variação da resistência à flexão e tenacidade à fratura em materiais vitrocerâmicos de dissilicato de lítio (LS2) em função do tamanho do precipitado e das frações volumétricas cristalinas, obtidos por ensaios mecânicos esferas sobre três esferas e flexão de quatro pontos, respectivamente. As temperaturas utilizadas nos tratamentos térmicos foram de 460 °C para nucleação e 538 °C para crescimento cristalino. As propriedades mecânicas das vitrocerâmicas apresentaram variação em relação à fração cristalina. A resistência à flexão do LS2 aumenta com o acréscimo da fração cristalina, sendo que quanto menor o tamanho do grão, maior é o valor da resistência à flexão, com valores para a amostra vítrea de 117 11 MPa, e para as amostras com fração cristalina de 98 % e cristal com diâmetro de 7 m, foi de 297 22 MPa. A tenacidade à fratura no dissilicato de lítio aumenta com a fração volumétrica cristalizada, sendo que quanto maior for o tamanho de grão, maior vai ser o valor de KIC. A tenacidade à fratura para a amostra vítrea apresentou valor de 0,80 0,09 MPa:m0;5 e para o cristal de diâmetro 34 m e fração de 80 %, KIC= 3,05 0,2 MPa:m0;5, um aumento de 280 % em relação ao vidro.
97

Efeito da adição de MgO na síntese de mulita “in situ”

Olcoski, Thays Allana 30 October 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2019-03-11T20:36:23Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) THAYS ALLANA OLCOSKI.pdf: 2638999 bytes, checksum: 786ecaaa8b03350890f4a8a81ad27819 (MD5) / Made available in DSpace on 2019-03-11T20:36:23Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) THAYS ALLANA OLCOSKI.pdf: 2638999 bytes, checksum: 786ecaaa8b03350890f4a8a81ad27819 (MD5) Previous issue date: 2018-10-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A mulita é a única fase cristalina formada no sistema SiO2-Al2O3, sendo um material refratário, com elevado ponto de fusão, excelente resistência ao choque térmico, resistividade elétrica e baixa condutividade térmica. Pode ser usada tanto em aplicações tradicionais quanto avançadas. Para a sua obtenção são necessárias elevadas temperaturas e longos tempos de sinterização, devido a necessidade de alta energia de ativação para ocorrer a difusão dos íons na rede da mulita. Para otimizar o processo, pode ser usado precursores em pó com tamanho de grãos submicrométricos ou usar aditivos de sinterização. Neste estudo foi usado como aditivo o MgO, para obter a mulita por sinterização reativa, a partir da mistura de Al(OH)3 e SiO2 coloidal, e da mistura de Al2O3 e SiO2 coloidal. Para verificar o seu efeito na mulitização e sinterização da mulita nessas composições, foram adicionadas 0,8; 1,6; 2,4; 3,1 e 3,9 % em peso de MgO. As composições foram sinterizadas à 1350, 1450 e 1550 ºC por 4 horas. Inicialmente as composições foram analisadas por dilatometria e análise térmica diferencial e termogravimétrica. E após sinterização foram analisadas por difração de raios X, fluorescência de raios X, medidas de densidade e porosidade aparentes, microscopia eletrônica de varredura, resistência à flexão em três pontos e espectroscopia de impedância. Pelos resultados obtidos, observou-se que a adição de MgO reduziu a temperatura de mulitização e a temperatura de sinterização das composições estudadas, de 1400 ºC para em torno de 1350 ºC. Além disso, observou-se que, quanto maior o teor de MgO e a temperatura de sinterização, maiores e mais anisotrópicos são os grãos de mulita formados e maior é a sua resistência a flexão. Sendo que a composição M5 sinterizada à 1550 ºC obteve o maior valor de resistência de 28 MPa. Houve uma redução drástica da porosidade à 1450 e 1550 ºC, ao contrário do que ocorreu à 1350 ºC, podendo ser observado nas imagens de MEV e pelos valores de porosidade aparente. Sendo que a composição M5 sinterizada à 1550 ºC obteve o menor valor de porosidade de 2 %, sendo que a composição M0 sinterizada na mesma temperatura obteve 13,1 %. As composições derivadas da mistura com alumina, obtiveram microestruturas mais densas, com menor porosidade e maior resistência à flexão. A composição MA1 sinterizada à 1450 ºC, obteve o maior valor de resistência no valor de 65,2 MPa, devido ao aparecimento da fase vítrea, que reforçou a sua microestrutura. Com o aumento da quantidade de MgO, houve a formação da fase espinélio, juntamente com a mulita, restando ainda α-alumina residual em algumas composições. No ensaio de espectroscopia de impedância, obteve-se apenas um semicírculo na representação de Nyquist, associado a contribuição apenas do interior do grão, com uma capacitância em torno de 10-11-10- 12 F. Notou-se que a condutividade elétrica do material é dependente da temperatura de ensaio, que quanto maior a temperatura maior a condutividade. Além do que, o aparecimento de fases como, espinélio, alumina e fase vítrea favoreceram a resistividade elétrica do material, consideravelmente. / The mullite is the only crystalline phase formed in the SiO2-Al2O3 system, being a refractory material with high melting point, excelente resistance to termal shock, electrical resistivity and low termal conductivity. It can be used traditional and advanced applications. High temperatures and long sintering times are required due to the high activation energy required to diffuse the ions in the mullite network. To optimize the process, power precursors with submicron grain size or using sintering additives. In this study, MgO was used to obtain the reactive sintering mullite from the mixture of Al(OH)3 and coloidal SiO2, and the mixture of Al2O3 and coloidal SiO2. To verify its effect on mulitization and sintering of mullite in these compositions, 0,8; 1,6; 2,4; 3,1 and 3,9 wt% MgO were added. The compositions were sintered at 1350, 1450 and 1550 ºC for 4 hours. Initially the compostions were analyzed by dilatometry and differential termal and thermogravimetric analysis. After sintering, they were analyzed by X ray diffraction, X ray fluorescence, apparent density and porosity measurements, scanning eléctron microscopy, three-point flexural strength and impedance spectroscopy. From the obtained results, it was observed that the addition of MgO reduced the mulitization temperature and the sintering temperature of the compositions studied, from 1400 ° C to around 1350 ° C. In addition, it has been observed that the higher the MgO contente and the sintering temperature, the larger and more anisotropic the mullite grains are formed and the greater their flexural strength. The composition M5 sintered at 1550 ºC obtained the highest resistance value of 28 MPa. There was a drastic reduction of porosity at 1450 and 1550 ºC, contrary to what happened at 1350 ºC, which can be observed in the SEM images and the values of apparent porosity. In which the composition M5 sintered at 1550 ºC obtained the lowest porosity value of 2%, and the composition M0 sintered at the same temperature obtained 13,1%. The composition MA1 sintered at 1450 ºC, obtained the highest value of resistance in the value of 65,2 MPa, due to the appearance of the glassy phase, which reinforced its microstructure. With the increase of the amount of MgO, there was formation of the spinel phase, together with the mullite, remaining residual α-alumina in some compositions. In the impedance spectroscopy test, only a semicircle was obtained in the Nyquist representation, associated with the contribution of only the interior of the grain, with a capacitance around 10-11-10-12 F. It was noted that the electrical conductivity of the material is dependent on the test temperature, that the higher the temperature the higher the conductivity. In addition, the appearance of phases such as spinel, alumina and vitreous phase favored the electrical resistivity of the material, considerably.
98

"Diferentes métodos de otimização da polimerização de resinas compostas de uso direto" / Different methods in optimizing the polymerization of direct resin composites

Almeida, Ana Maria Lima 09 December 2005 (has links)
Este trabalho avaliou a influência da densidade de energia da pré-cura, e de diferentes tratamentos pós-cura na otimização das propriedades físicas (Resistência à Flexão e Dureza Knoop) de resinas compostas diretas, visando a possibilidade de indicação para restauraçoes indiretas. Foram usadas as resinas diretas Fillmagic, Concept, Glacier, Z100, Masterfill e W3D Master e as indiretas Solidex e Belleglass HP como controle. Para cada resina direta foram confeccionados 60 espécimes em barra (10x2x2mm), 30 irradiados em uma face e 30 nas duas faces (30 espécimes = 10 controle, 10 autoclave e 10 forno de luz). Para as resinas indiretas foram preparados 10 espécimes conforme processamento de seus fabricantes. 380 espécimes foram submetidos ao ensaio de resistência à flexão (Kratos). De cada condição experimental, 10 fragmentos foram usados para ensaio de microdureza Knoop (Shimadzu HMV-2). A análise de variância e o teste de Tukey demonstraram significância para resistência à flexão nos fatores Resina (p<0,001) e Tratamento (p=0,001) e na interação Resina x Tratamento (p=0,001). Para a microdureza Knoop os três fatores e as interações foram significantes: Resina (p=0,001); Face (p=0,001) Tratamento (p=0,017); Resina x Face (p=0,001); Resina x Tratamento (p=0,007); Face x Tratamento (p=0,001) e Resina x Face x Tratamento (p=0,024). A maior média de cada resina direta, independente da condição experimental, foi comparada às médias das resinas indiretas. Os resultados apontam que na resistência à flexão (Z100 = W3D = Fillmagic = Glacier) e (Z100 > Masterfill > Belleglass HP > Concept > Solidex). Na Dureza Knoop (Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill e Solidex). Conclusão: as propriedades físicas (resistência à flexão e dureza Knoop) não são obstáculos na indicação de resinas compostas de uso direto para restaurações indiretas / This study evaluated the influence of pre-cure energy density, and additional post-cure treatments in optimizing the physical properties (Flexural strength and Knoop microhardness) of direct resin composites with the aim at allowing their use for indirect restorations. Direct resin composites evaluated were Fillmagic, Concept, Glacier, Z100, Masterfill and W3D Master; indirect composites were Solidex and Belleglass HP. Sixty bar-shaped specimens (10x2x2mm) were prepared for each material, so that 30 of them were light-cured by one surface and 30 on both surfaces. From the 30 specimens of each group, 10 were control, 10 were submitted to additional autoclave and 10 to light oven treatment. Ten specimens were prepared with each indirect composite following the manufactures’ recommendations. The 380 specimens were submitted to flexural strength test (Kratos universal testing machine), and values obtained at fracture were reported. After that, 10 fragments were chosen for each experimental condition and assessed for Knoop microhardness (Shimadzu HMV-2). Data were submitted to analysis of variance and Tukey’s test at p<0.05. Statistically significant differences were found among flexural strength results regarding composite materials (p<0.001), treatments (p<0.001) and interactions (composite x treatment, p<0.001). Regarding Knoop microhardness, both three factors and their interactions were also significant: composite (p<0.001), surface (p<0.001) and treatment (p<0.017), composite x surface (p<0.001), composite treatment (p<0.001), surface x treatment (p<0.001) and composite x surface x treatment (p<0.024). The highest mean value for each direct composite, regardless of the experimental condition, was compared to the mean values obtained for the indirect materials. With regard to flexural strength, comparisons point out that Z100 = W3D = Fillmagic = Glacier and Z100 > Masterfill > Belleglass HP > Concept > Solidex, whereas for Knoop microhardness Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill and Solidex. Conclusion: considering the physical properties evaluated in this study, they are not an obstacle to the indication of direct composites for indirect restorations
99

Use of non-steel fiber reinforcement in concrete tunnel lining

Seo, Sang Yeon 26 January 2011 (has links)
Fiber reinforcement is being widely used in concrete tunnel linings these days. Using fiber reinforcement can save not only cost, but also labor and time spent on construction. However, many owners hesitate to incorporate fiber reinforcement in tunnel lining due to lack of experience with and knowledge of the behavior of fiber reinforced concrete (FRC) In this study, fiber reinforced concrete was made with various kinds of fibers such as steel fiber, macro-synthetic fiber and hybrid fiber (a blend of macro-synthetic fiber and glass fiber). Many experimental tests were performed to investigate the compressive, flexural and shear behavior of fiber reinforced concrete. In addition to the structural capacity of FRC, the distribution of fiber reinforcement inside the concrete matrix was investigated. Test results of these experimental tests were thoroughly examined to compare and quantify the effects of fiber reinforcement. Next, the test results were used to generate axial force-bending moment interaction diagrams based on current design approaches. In addition, the current design approaches were modified to estimate the accurate and exact value of bending moment. Fiber reinforcement clearly improved the structural performance of tunnel lining. The post-peak flexural and shear strength was significantly influenced by the type and amount of fiber reinforcement. / text
100

Influência de substâncias irrigadoras endodônticas nas propriedades mecânicas da dentina radicular

Queiroz, Ellyne Cavalcanti 13 March 2007 (has links)
The aim of this study was to evaluate the influence of different endodontic irrigants on the cohesive and flexural strength of the root dentin. One hundred of bovine incisor roots were selected, instrumented and randomly divided into 10 experimental groups (n = 10), according to the irrigation solution used: Control - physiological solution; N1 - sodium hypochlorite 1.0%; N5 - sodium hypochlorite 5.25%; N1EDTA - sodium hypochlorite 1.0% associate to EDTA 17%; N5EDTA - sodium hypochlorite 5.25% associate to EDTA 17%; Sclx chlorhexidine gluconate solution 2.0%; Gclx - chlorhexidine gluconate gel 2.0%; SclxEDTA - chlorhexidine gluconate solution 2.0% associate to EDTA 17%; GclxEDTA - chlorhexidine gluconate gel 2.0% associate to EDTA 17% and EDTA - EDTA 17%. The roots were axially sectioned in two halves. Half of them were used for the microtensile cohesive strength test: six 1.0mm thick slices were trimmed to produce hourglass shaped samples with a test area of 1mm2. The other halves were used in a 3-point bend flexural strength by means of dentine bars with 1X1X12 mm. Each sample remained two hours in contact with the irrigant solutions, except for EDTA, which remained for five minutes. After irrigants treatment, samples were rinsed with distilled water, and tested. Specific devices for each test were used, in a universal testing machine with a load cell of 20Kgf, and a crosshead speed of 0.5 mm/minute. Date were recorded and statistically analyzed with one-way ANOVA and Tukey test. Significant reduction in the ultimate cohesive strength and flexural strength was verified only for the groups that used sodium hypochlorite irrespective of the concentration and additional solution, differing significant from the group control. The use of chlorhexidine and EDTA separately did not cause alteration in the mechanical properties of root dentine. / O objetivo desse estudo foi avaliar a influência de diferentes irrigantes endodônticos na resistência coesiva e flexural da dentina radicular. Cem raízes de incisivos bovinos foram selecionadas, instrumentadas e divididas aleatoriamente em 10 grupos experimentais (n= 10), de acordo com a substância irrigadora utilizada: Controle - solução fisiológica; N1 - hipoclorito de sódio a 1,0%; N5 - hipoclorito de sódio a 5,25% ; N1EDTA - hipoclorito de sódio a 1,0% associado à EDTA a 17%; N5EDTA - hipoclorito de sódio a 5,25% associado à EDTA a 17%; Sclx - solução de gluconato de clorexidina a 2,0%; Gclx - gel de gluconato clorexidina a 2,0%; SclxEDTA - solução de gluconato clorexidina 2,0% associado à EDTA a 17%; GclxEDTA - gel de gluconato clorexidina a 2,0% associado à EDTA a 17% e EDTA - EDTA a 17%. As raízes foram axialmente seccionadas em duas metades. Uma metade foi utilizada para ensaio de microtração, da qual foram obtidas seis fatias de 1,0mm de espessura que receberam constrições na face externa, determinando área de teste de 1mm2. A outra metade foi utilizada no ensaio de flexão de 3-pontos, da qual foi extraída uma barra de dentina com dimensões de 1X1X12 mm. Cada amostra permaneceu duas horas em contato com a substância irrigante endodôntica com exceção do EDTA, que atuou por cinco minutos. Após o tratamento com os irrigantes, procedeu-se a lavagem com água destilada, e em seguida executados os ensaios mecânicos. Foram utilizados dispositivos específicos para cada ensaio, acoplados à máquina de ensaio mecânico, utilizando célula de carga de 20Kgf, com velocidade de 0,5 mm/minuto até a fratura da amostra. Os dados obtidos foram submetidos à análise de variância e teste Tukey. Verificou-se redução significativa na resistência máxima coesiva e flexural apenas para os grupos que empregaram o hipoclorito de sódio independe da concentração e associação com outra substância, diferindo estatisticamente do grupo controle. O uso de clorexidina e EDTA isoladamente não alterou as propriedades mecânicas da dentina radicular. / Mestre em Odontologia

Page generated in 0.0845 seconds