• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 148
  • 111
  • 33
  • 14
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • Tagged with
  • 375
  • 94
  • 93
  • 79
  • 57
  • 48
  • 45
  • 36
  • 35
  • 32
  • 29
  • 25
  • 25
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Improvement of the retention-fromation relationship using three-component retention aid systems

Svedberg, Anna January 2012 (has links)
QC 20120530
352

Tratamento de efluentes líquidos de unidades produtoras de farinha de mandioca

Roberto Albuquerque Lima 05 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A mandioca (Manihot esculenta) é a terceira cultura mais importante do país na alimentação básica da população. A produção de farinha de mandioca gera um efluente denominado manipueira que contem elevada quantidade de matéria orgânica e cianeto. O objetivo deste trabalho foi investigar a remoção da demanda química de oxigênio (DQO), turbidez e cianeto da manipueira por tratamentos físico-químico e biológico. No tratamento físico-químico por coagulação-floculação, três planejamentos fatoriais completos foram realizados para investigar os fatores: pH, tanino e o polímero sintético auxiliar da floculação (Polipan) sobre as variáveis respostas: DQO, turbidez e cianeto. A eficiência máxima de remoção de DQO foi 91 % a pH 8,0, na presença de tanino 1,0 mL/L e Polipan 0,030 ppm. A maior remoção de turbidez (75 %) foi determinada a pH 8 e tanino 0,8 mL/L, na ausência do Polipan para diminuir os custos do tratamento. Nessas condições, a redução máxima de cianeto foi de 12 %. Nos tratamentos biológicos aeróbios durante 48 h, as eficiências máximas de redução de DQO 88 % e de turbidez 69 % foram determinadas na presença de consórcio microbiano 20 % v/v, cloreto de amônio 5 - 6 % e a pH 8,0. Para os tratamentos físico-químico e biológico, os resultados obtidos mostram que o pH 8 foi fator chave para remoção de compostos orgânicos e do cianeto da manipueira. Os tratamentos da manipueira por coagulação-floculação e por consórcio microbiano diminuem a carga orgânica desse efluente antes de ser lançado nos recursos hídricos / Cassava (Manihot esculenta) is the third most important crop in the basic food of the Brazilian population. The production of cassava flour generates an effluent, called manipueira, containing high organic matter and cyanide. The objective of this study was to investigate the removal of chemical oxygen demand (COD), turbidity and cyanide from cassava wastewater by physical-chemical and biological treatments. In the physicalchemical treatment by coagulation-flocculation, three full factorial designs were carried out to investigate the factors: pH, tannin concentration and the flocculation polymer (Polipan) concentration on the response variables: COD, turbidity and cyanide. The maximum efficiency for COD removal was 91 % at pH 8.0 in the presence of tannin 1.0 mL/L and Polipan 0.030 ppm. The highest removal of turbidity (75 %) was determined at pH 8 and tannin 0.8 mL/L in the absence of Polipan to reduce the costs of treatment. Under these conditions, the maximum removal of cyanide was 12 %. In the aerobic biological treatment for 48 h, the maximum efficiencies for COD reduction of 88 % and for turbidity reduction of 69 % were determined in the presence of the microbial consortium 20 % v/v, ammonium chloride 5 6 % and at pH 8.0. For the treatments, physical-chemical and biological, the results show that pH 8 is a key factor for removal of organic compounds and cyanide from cassava wastewater. The treatments of the manipueira by coagulation-flocculation and by microbial consortium decrease the pollution of this effluent before being launched in the water resources
353

Avaliação da viabilidade de cistos de Giardia spp. e oocistos de Cryptosporidium parvum em água filtrada obtida após tratamento convencional com flotação e ozonização / Viability assessment of Giardia spp. cysts and Cryptosporidium parvum oocysts in filtered water obtained after conventional treatment with flotation and ozonation

Dayane Mendes Boni 09 September 2016 (has links)
Esta pesquisa avaliou o uso de ozônio para inativar cistos de Giardia spp. e oocistos de Cryptosporidium parvum presentes na água filtrada obtida após a utilização da tecnologia de ciclo completo com flotação (coagulação, floculação, flotação e filtração) em escala de bancada, empregando o cloreto de polialumínio – PAC – como coagulante. O método de floculação em carbonato de cálcio – FCCa, sem e com a etapa de separação imunomagnética – IMS – foi utilizado na quantificação dos protozoários. A recuperação nos ensaios de qualidade utilizando o kit Easyseed® de Giardia spp. foi de 8,4% ± 97,4% sem IMS e com IMS, com duas dissociações, o valor foi de 7,4% ± 39,7% e, com três dissociações, a recuperação alcançou 9,6% ± 34,7%, portanto, somente o ensaio com IMS e duas dissociações, não atendeu os padrões do Método 1623.1. A recuperação de Cryptosporidium parvum, obteve valor de 3,4% ± 100% em ensaio sem IMS e com IMS, o valor obtido foi de 1,0% ± 70,0% com duas dissociações e 1,8% ± 44,4% com três dissociações e nos três métodos apresentados, não houve conformidade com os critérios do Método 1623.1. Na etapa de desinfecção com ozônio, os ensaios realizados na Etapa 1, que se utilizou 5 mgO3L-1 e tempo de contato de 1 min sem IMS, as maiores inativações atingidas foram de 2,52 e 2,22 log para cistos de Giardia spp. e oocistos de Cryptosporidium parvum, respectivamente. Com o tempo de contato de 5 min, as maiores inativações foram de 2,52 e 2,92 log de cistos de Giardia spp. e oocistos de Cryptosporidium parvum, respectivamente. Na Etapa 2, com IMS, utilizando a mesma dosagem e tempo de contato de 1 min, obteve-se 2,27 e 0,21 log de inativação para cistos e oocistos, respectivamente. Comparando-se com o tempo de contato de 5 min, foram obtidos 2,9 e 2,3 log de inativação para cistos e oocistos, respectivamente. Na avaliação de custo, o método de FCCa sem IMS demonstrou ser o mais econômico em relação ao procedimento com IMS. A influência da inclusão da terceira dissociação ácida no método com IMS também foi analisada e este procedimento não resultou em diferenças estatísticas significativas nos resultados. / This research evaluated the use of ozone to inactivate Giardia spp. cysts and Cryptosporidium parvum oocysts present in the filtered water obtained after the use of the complete cycle of flotation technology (coagulation, flocculation, flotation and filtration) on a bench scale employing polyaluminium chloride - PAC as coagulant. The calcium carbonate flocculation method - FCCa, without and with immunomagnetic separation step - IMS has been used in the quantification of protozoa. The recovery in quality test using the kit Easyseed® for Giardia spp. was 8.4% ± 97.4% non-IMS and IMS with two dissociations, the value was 7.4% ±39.7% and with three dissociations, the recovery reached 9.6% ± 34,7%, so only the test with IMS and two dissociations, did not meet the standards of method 1623.1. Recovery of Cryptosporidium parvum obtained value of 3.4% ± 100% in non-IMS and IMS testing, the value obtained was 1.0% ± 70.0% with two dissociations and 1.8% ± 44.4% with three dissociations and the three methods presented, there was non-compliance with the criteria of Method 1623.1. In step disinfection with ozone, tests performed in Step 1 was used 5 mgO3L-1 and contact time of 1 min without IMS, the major inactivation achieved were 2.52 and 2.22 log for Giardia spp. cysts and Cryptosporidium parvum oocysts, respectively. With 5 minutes of contact time, the greater inactivation were 2.52 and 2.92 log for Giardia spp. cysts and Cryptosporidium parvum oocysts, respectively. In Step 2, with IMS, using the same dose and 1 min contact time, there was obtained 2.27 and 0.21 log inactivation for cysts and oocysts, respectively. Compared with the 5 min of contact time, were obtained 2.9 and 2.3 log inactivation for cysts and oocysts, respectively. In evaluating cost, the FCCa method without IMS proved to be the most economical in relation to the procedure with IMS. The influence of inclusion of the third acid dissociation method in IMS was also analyzed and this procedure did not result in statistically significant differences in the results.
354

Recuperação de águas residuárias geradas na indústria de produtos lácteos por sistema híbrido para fins de reúso / Recovery of wastewaters generated by the dairy industry applying a hybrid system for reuse purposes

Schmitt, Dalila Maria Formentini 05 March 2018 (has links)
Submitted by Marilene Donadel (marilene.donadel@unioeste.br) on 2018-05-10T00:06:25Z No. of bitstreams: 1 Dalila_Schmitt_2018.pdf: 2548931 bytes, checksum: 5ee22f914bbdcce603c158d7a45f4786 (MD5) / Made available in DSpace on 2018-05-10T00:06:26Z (GMT). No. of bitstreams: 1 Dalila_Schmitt_2018.pdf: 2548931 bytes, checksum: 5ee22f914bbdcce603c158d7a45f4786 (MD5) Previous issue date: 2018-03-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The whey industrialization process generates effluents that need a special attention regarding treatment and final disposal. Currently, many advanced treatment techniques have been studied in order to provide a treated water with high quality for reuse purposes. In this context, this work aimed at evaluating the efficiency of a hybrid system based on coagulation/flocculation/sedimentation (C/F/S) and nanofiltration (NF) for industrial reuse purposes. In the C/F/S process, the use of Moringa oleifera Lam (Moringa) seeds as a natural coagulant was evaluated. Different methods and saline solutions (KCl, MgCl2.6H2O, and CaCl2.2H2O) were studied when extracting the active components from the seeds. Nanofiltration was performed with polyamide membranes based on the tangential flow filtration principle. The extraction method that utilized the whole Moringa, ground directly with the saline solution, was highlighted among the evaluated ones, by using a smaller number of steps. The extraction with calcium chloride dehydrated demonstrated the best efficiency, compared to the magnesium chloride hexahydrate and potassium chloride. The C/F/S step was optimized through serial factorial designs, in which the turbidity removal was the response variable. It was obtained a turbidity removal of 91.52% when using 300 mg L-1 of the Moringa coagulant (MC), extracted with a saline CaCl2.2H2O solution (0.9 mol L-1) and a pH value of 10.0. The empirical quadratic model obtained, validated by the ANOVA and F-test, in conjunction with the desirability function, demonstrated the possibility to obtain turbidity removals of 92.04 % ( 9.13%) with the following conditions: MC = 300 mg L-1, CCaCl2 = 0.9 mol L-1 e pH = 11.0. The sedimentation time was reduced from 40 to 25 minutes. The MC performance concerning the turbidity removal proved to be dependent on the alkaline pH (8.0 to 11.0). In the nanofiltration process, it was evaluated the influence of the C/F/S optimized as a pre-treatment, comparing the hybrid C/F/S/NF and the direct NF at 4 bar. High removals of apparent color (99.7%), turbidity (99.1%), COD (88.9%), total hardness (66.3%), and calcium (63.7%) were obtained using the hybrid treatment system, providing a removal of 81.2% in the membrane fouling, compared to the raw NF treatment. The proposed hybrid system allows the reuse of this wastewater in the industry. / O processo de industrialização do soro de leite gera águas residuárias que necessitam de atenção especial, quanto ao seu tratamento e disposição final. Atualmente, muitas técnicas de tratamento avançadas são estudadas com o objetivo de produzir águas tratadas de elevada qualidade, para fins de reuso. Dentro deste contexto, o presente trabalho teve como objetivo avaliar a eficiência de um sistema de tratamento híbrido, composto por coagulação/floculação/sedimentação (C/F/S) e nanofiltração (NF), para fins de reuso industrial. No processo de C/F/S, foi avaliado o uso das sementes de Moringa oleífera Lam (Moringa) como coagulante natural. Foram avaliados diferentes métodos e soluções salinas (KCl, MgCl2.6H2O e CaCl2.2H2O) na extração dos componentes ativos das sementes. A nanofiltração foi realizada com membranas planas de poliamida pelo princípio de filtração tangencial. O método de extração no qual a Moringa integral foi triturada diretamente com a solução salina destacou-se dentre os avaliados, por utilizar um número menor de etapas. A extração com o cloreto de cálcio dihidratado, demonstrou ser mais eficiente, em comparação aos sais cloreto de magnésio hexahidratado e cloreto de potássio. A etapa de C/F/S foi otimizada através de planejamentos fatoriais em série, nos quais, utilizou-se a remoção de turbidez como variável resposta. Foi obtida uma remoção de turbidez de 91,52 %, ao utilizar 300 mg L-1 de coagulante de Moringa (CM), extraído com solução salina de CaCl2.2H2O (0,9 mol L-1) e pH 10,0. O modelo quadrático empírico obtido, validado pela ANOVA e teste “F”, juntamente com a função desejabilidade, demonstraram ser possível obter remoção de turbidez de 92,04 % ( 9,13 %), nas seguintes condições: CM = 300 mg L-1; CCaCl2= 0,9 mol L-1 e pH = 11,0. O tempo de sedimentação foi reduzido de 40 para 25 minutos. O desempenho de CM para remoção de turbidez demonstrou ser dependente do pH alcalino (8,0 a 11,0). No processo de nanofiltração avaliou-se a influência de C/F/S otimizado como pré-tratamento, compondo o tratamento híbrido C/F/S/NF, em comparação ao tratamento por NF direto (Bruto-NF), na pressão de 4 bar. Elevadas remoções de cor aparente (99,7 %), turbidez (99,1 %), DQO (88,9%), dureza total (66,3 %) e cálcio (63,7 %) foram obtidas utilizando o sistema de tratamento híbrido, que proporcionou redução de 81,2% no fouling da membrana, em comparação ao tratamento Bruto-NF. O sistema híbrido proposto possibilita o reuso desta água dentro da indústria.
355

Performance do processo de coagulação/floculação no tratamento do efluente líquido gerado na galvanoplastia / Performance process coagulation/flocculation in the treatment of effluent generated in electroplating

Vaz, Luiz Gustavo de Lima 17 February 2009 (has links)
Made available in DSpace on 2017-07-10T18:08:14Z (GMT). No. of bitstreams: 1 Luiz G de Lima Vaz.pdf: 2121268 bytes, checksum: 8362ccb905b9c1c473a10787d8b74866 (MD5) Previous issue date: 2009-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The process of electroplating effluents with high levels of heavy metals and large amounts of dissolved and suspended materials, resulting in high values of color and turbidity, respectively. Because of these characteristics, the effluent of electroplating industries require efficient processes to achieve the levels of concentration and physical and chemical parameters recommended by the environmental legislation. In this context we evaluated the efficiency of organic coagulants (seeds of Moringa oleifera Lam, chitosan, Tanfloc SG and Acquapol C1) and inorganic (aluminum sulfate and ferric chloride) in the first stage of wastewater treatment of electroplating through a planning saturated Plackett and Burman (PB12) followed by a central composite rotational design (DCCR). The following variables were studied: concentration (C), velocity of rapid mixing (VMR) and slow (VML) and time of rapid mix (TMR) and slow (TML), with 30 min of sedimentation, and the response variables analyzed for each coagulant: color, turbidity, settleable solids and COD. Among the agents coagulants/flocculants tested after the completion of PB12, the best combination of results for the removal of the studied parameters occurred with chitosan. The operating conditions were optimized by the statistical program: TMR of 100 rpm, TML of 20 rpm, VMR and VML of 6 and 30 min, respectively, concentration of 12.67 ppm and sedimentation time of 30 min. These conditions it is expected to remove 89.44% of color, 96.87% of turbidity and 35.81% of COD. Based on the results obtained chitosan presented a promising coagulant to the wastewater treatment of electroplating. / Os processos de galvanização geram efluentes com elevados teores de metais pesados e grande quantidade de materiais dissolvidos e suspensos, ocasionando altos valores de cor e turbidez, respectivamente. Devido a estas características o efluente das indústrias de galvanoplastia requerem processos eficientes para alcançar os níveis de concentração e parâmetros físico-químicos recomendados pela legislação ambiental. Neste contexto o presente trabalho avaliou a eficiência de coagulantes orgânicos (sementes de Moringa oleifera Lam, quitosana, Tanfloc SG e Acquapol C1) e inorgânicos (sulfato de alumínio e cloreto férrico) na primeira etapa de tratamento de efluente de galvanoplastia, por meio de um planejamento de Plackett e Burman (PB12) seguido de um Delineamento Composto Central Rotacional (DCCR). As seguintes variáveis foram estudadas: concentração (C), velocidade de mistura rápida (VMR) e lenta (VML) e tempo de mistura rápida (TMR) e lenta (TML), com 30 min de sedimentação, sendo as variáveis de resposta analisadas para cada coagulante: cor, turbidez, sólidos sedimentáveis e DQO. Dentre os agentes coagulantes/floculantes testados, após a realização do PB12, a melhor combinação de resultados para a remoção dos parâmetros estudados ocorreu com a quitosana. As condições operacionais otimizadas pelo programa estatístico foram: TMR de 100 rpm, TML de 20 rpm, VMR e VML de 6 e 30 min, respectivamente, concentração de 12,67 ppm e tempo de sedimentação de 30 min. Nestas condições espera-se remover 89,44% de cor, 96,87% de turbidez e 35,81% de DQO. Com base nos resultados obtidos a quitosana se apresentou um coagulante promissor para o tratamento do efluente de galvanoplastia.
356

PARÂMETROS DE SOLUBILIDADE DE HILDEBRAND DOS PETRÓLEOS E DA MISTURA PETRÓLEO-HEPTANO NO LIMIAR DA PRECIPITAÇÃO DOS ASFALTENOS EMPREGANDO MICROSCOPIA ÓPTICA E ESPECTROSCOPIA DE INFRAVERMELHO-PRÓXIMO (NIR) / HILDEBRAND SOLUBILITY PARAMETERS OF THE OIL AND MIXING OIL-HEPTANE ON THE THRESHOLD OF THE PRECIPITATION EMPLOYEE ASPHALTENES MICROSCOPY OPTICS AND SPECTROSCOPY A NEAR-INFRARED (NIR)

Castro, Ariana Komura de 03 July 2009 (has links)
Made available in DSpace on 2016-08-19T12:56:34Z (GMT). No. of bitstreams: 1 Ariana Komura de Castro.pdf: 1539013 bytes, checksum: 9322eebdf7e436f3bca6297342a522b1 (MD5) Previous issue date: 2009-07-03 / The Hildebrand solubility parameter is used to express the compatibility of petroleum in mixtures, starting from the principle that, independently from the system composition, the asphaltenes always precipitate in a certain solubility parameter, known as the flocculation parameter, which estimated value is 16,35 (MPa)1/2. In this paper, it was tried to experimentally determine the flocculation parameter and the solubility parameters of some petroleum, through data of onset of precipitation of asphaltenes by adding n-alkenes. The experimental determinations of onset of precipitation were performed by optical microscopy and Near-Infrared spectroscopy (NIR), in order to be also evaluated the correlation between measures. The outcomes of onset of precipitation showed a reasonable correlation among techniques, but the data obtained by NIR were generally larger. Towards the flocculation parameter, the experimental data when adjusted to a linear behavior of first order ended up on inconsistent values compared with the ones in literature, what raised doubts about the basic hypothesis of compatibility model. However, it was possible the determination of solubility parameters for several petroleum and it was noticed that the data are used successfully in prediction of compatibility in mixtures, therefore, it was verified the need of the improvement of experimental methodology to the determination of onset of precipitation through Near-Infrared spectroscopy and clues indicate that the phenomena of asphaltenes precipitation may not be only molecular. / O parâmetro de solubilidade de Hildebrand é utilizado para expressar a compatibilidade de petróleos em misturas, partindo-se do princípio que, independentemente da composição do sistema, os asfaltenos precipitam sempre em um determinado parâmetro de solubilidade, conhecido como parâmetro de floculação, cujo valor estimado é 16,35 (MPa)1/2. Neste trabalho, tentou-se determinar experimentalmente o parâmetro de floculação e os parâmetros de solubilidade de alguns petróleos, através dos dados de início de precipitação dos asfaltenos pela adição de n-alcanos. As determinações experimentais de início de precipitação foram realizadas por microscopia ótica e espectroscopia de Infravermelho Próximo (NIR), a fim de que fosse avaliada também a correlação entre as medidas. Os resultados de início de precipitação indicaram uma correlação razoável entre as técnicas, mas os dados obtidos pelo NIR foram geralmente maiores. Em relação ao parâmetro de floculação, os dados experimentais quando ajustados a um comportamento linear de primeira ordem proporcionou valores inconsistentes comparados com o da literatura, o que coloca em dúvida a hipótese básica do modelo de compatibilidade. Entretanto, foi possível a determinação dos parâmetros de solubilidade para vários petróleos e foi observado que os dados são utilizados com sucesso na predição da compatibilidade em misturas, porém, verificou-se a necessidade do aperfeiçoamento da metodologia experimental para a determinação do início de precipitação através da espectroscopia de infravermelho próximo e indícios apontam que o fenômeno da precipitação dos asfaltenos possa não ser apenas molecular.
357

Otimização do método de floculação orgânica de concentração viral para avaliação do impacto de tratamento por lodo ativado na Estação de Tratamento de Esgoto Barbosa Lage, Juiz de Fora - Minas Gerais

Assis, Andrêssa Silvino Ferreira 19 December 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-13T17:29:42Z No. of bitstreams: 1 andressasilvinoferreiraassis.pdf: 3364177 bytes, checksum: ff9c20080e11e36f28daf805d56ecc7e (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-13T19:33:58Z (GMT) No. of bitstreams: 1 andressasilvinoferreiraassis.pdf: 3364177 bytes, checksum: ff9c20080e11e36f28daf805d56ecc7e (MD5) / Made available in DSpace on 2017-03-13T19:33:58Z (GMT). No. of bitstreams: 1 andressasilvinoferreiraassis.pdf: 3364177 bytes, checksum: ff9c20080e11e36f28daf805d56ecc7e (MD5) Previous issue date: 2016-12-19 / O tratamento de esgoto pode ser insuficiente para a completa eliminação de vírus entéricos, tais como adenovírus humanos (HAdV) e rotavírus do grupo A (RVA). Portanto, o retorno do lodo e do efluente tratado ao ambiente pode representar riscos à saúde pública. Este estudo foi conduzido para otimizar um protocolo de floculação orgânica para recuperação viral a partir de lodo de esgoto e efluente tratado, bem como realizar um monitoramento de HAdV e RVA na estação de tratamento de esgoto (ETE) de Juiz de Fora, MG. Nos estudos de otimização, foram propostas adaptações no protocolo de floculação com leite desnatado para lodo e efluente tratado, com modificações no tempo de agitação da amostra, na concentração final de leite desnatado e/ou na etapa de centrifugação. No estudo de monitoramento, esgoto bruto (P1), esgoto primário (P2), lodo (P3) e efluente tratado (P4) foram coletados bimensalmente em 2014 (durante as épocas seca e chuvosa), totalizando 96 amostras (simples e compostas). As cargas virais foram determinadas por PCR quantitativo e o bacteriófago PP7 foi usado como controle interno. Amostras de HAdV e RVA foram submetidas ao sequenciamento e a viabilidade das partículas de HAdV foi avaliada em amostras de P4. Os parâmetros físico-químicos e a contagem de coliformes termotolerantes (CT) foram determinados em cada ponto. Nos estudos de otimização, foram selecionadas duas condições que apresentaram as maiores taxas de recuperação viral no lodo (menor tempo de agitação e maior concentração de leite desnatado) e no efluente tratado (sem primeira etapa de centrifugação e com maior concentração de leite desnatado). Ambas provaram ser ferramentas úteis para pesquisa viral em amostras de campo, inclusive para a pesquisa de vírus gigantes. No monitoramento, o HAdV foi detectado em 85,4% (82/96) dos concentrados, com cargas virais variando de 3,27 x 102 a 2,42 x 106 cópias do genoma por mililitro (cg/mL), ao longo do ano. A presença de RVA foi observada em 52,1% (50/96) dos concentrados (1,38 x 103 a 3,65 x 105 cg/mL), com maior detecção na época seca. A carga viral não foi influenciada pelo tipo de amostra, sendo detectada tanto em amostras simples, quanto em amostras compostas. Todas as amostras de HAdV sequenciadas pertenciam à espécie F tipo 41 e as amostras de RVA pertenciam ao genótipo I1. O tratamento de esgoto reduziu a quantidade de matéria orgânica e sólidos, bem como a contagem de CT e as cargas virais. No entanto, a presença de HAdV e RVA foi observada mesmo após o tratamento, inclusive em amostras de efluente tratado consideradas adequadas pelas legislações atuais, com detecção de partículas infecciosas de HAdV. Foram observadas correlações positivas entre a carga viral e a demanda bioquímica de oxigênio, os sólidos sedimentáveis e sólidos suspensos totais. Os dois protocolos otimizados neste estudo podem ser facilmente adequados para uso em laboratório de rotina, podendo impulsionar o monitoramento viral nos subprodutos gerados na ETE. A carga viral detectada na ETE salienta a disseminação ambiental de RVA e HAdV e aponta o potencial do HAdV como um marcador viral de contaminação em ambientes aquáticos. / Sewage treatment may be insufficient for the complete elimination of enteric viruses such as human adenoviruses (HAdV) and group A rotaviruses (RVA). Thus, the return of sewage sludge and treated effluent to the environment poses concerns potential for public health. This study was conducted to optimize an organic flocculation procedure for viral recovery from sludge and treated effluent, and carry out a surveillance of HAdV and RVA in a wastewater treatment plant (WWTP) at Juiz de Fora, MG. In optimization studies, conditions were proposed for sludge and treated effluent with changes in the stirring time, in the final concentration of skimmed-milk and/or in the centrifugation step. In surveillance study, raw sewage (P1), primary sewage (P2), sludge (P3) and treated effluent (P4) were collected bimonthly in 2014 (during the dry and the rainy season), totaling 96 samples (simple and composite). Quantitative PCR determined viral loads and PP7 bacteriophage was used as internal control. HAdV and RVA strains were selected for sequencing, and the HAdV viability was evaluated in P4 samples. Physicochemical parameters and thermotolerant coliforms (TC) counting were determined at each point. After the optimization studies, two conditions were selected: the ones that showed the highest viral recovery rates in sludge (lower stirring time and higher concentration of skimmed-milk) and treated effluent (without the first centrifugation step and with a higher concentration of skimmed-milk). These conditions proved to be a useful tool for viral search in the field samples, including for the research of giant virus. In surveillance study, HAdV was detected in 85.4% (82/96) of the concentrated, with viral loads ranging from 3.27 x 102 to 2.42 x 106 genome copies per milliliter (gc/mL), throughout the year. RVA presence was observed in 52.1% (50/96) of the samples (1.38 x 103 to 3.65 x 105 gc/mL) with detection greater in the dry season. Viral load was not influenced by the type of sample being detected both in single samples, as in composite samples. All the sequenced HAdV strains belonged to species F type 41, and RVA strains belonged to genotype I1. Sewage treatment reduced the content of organic matter and solids, as well as the TC counts and the viral loads. However, the presence of HAdV and RVA was observed after treatment, even in samples considered adequate by current laws with detection of infectious HAdV particles. Positive correlations were observed between viral load and biochemical oxygen demand, sedimented solids and total suspended solids. Two optimized protocols in this study are easily suitable for routine laboratory use and can boost viral monitoring in by-products generated in the WWTP. Viral load detected in WWTP stress the environmental dissemination of HAdV and RVA and addressed the potential of HAdV as a virological marker of contamination in aquatic environments.
358

Tratamento de efluentes líquidos de unidades produtoras de farinha de mandioca

Lima, Roberto Albuquerque 05 February 2010 (has links)
Made available in DSpace on 2017-06-01T18:20:28Z (GMT). No. of bitstreams: 1 dissertacao_roberto.pdf: 771972 bytes, checksum: 84b4fdd96e095e36234f411eb7d531d5 (MD5) Previous issue date: 2010-02-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Cassava (Manihot esculenta) is the third most important crop in the basic food of the Brazilian population. The production of cassava flour generates an effluent, called manipueira , containing high organic matter and cyanide. The objective of this study was to investigate the removal of chemical oxygen demand (COD), turbidity and cyanide from cassava wastewater by physical-chemical and biological treatments. In the physicalchemical treatment by coagulation-flocculation, three full factorial designs were carried out to investigate the factors: pH, tannin concentration and the flocculation polymer (Polipan) concentration on the response variables: COD, turbidity and cyanide. The maximum efficiency for COD removal was 91 % at pH 8.0 in the presence of tannin 1.0 mL/L and Polipan 0.030 ppm. The highest removal of turbidity (75 %) was determined at pH 8 and tannin 0.8 mL/L in the absence of Polipan to reduce the costs of treatment. Under these conditions, the maximum removal of cyanide was 12 %. In the aerobic biological treatment for 48 h, the maximum efficiencies for COD reduction of 88 % and for turbidity reduction of 69 % were determined in the presence of the microbial consortium 20 % v/v, ammonium chloride 5 6 % and at pH 8.0. For the treatments, physical-chemical and biological, the results show that pH 8 is a key factor for removal of organic compounds and cyanide from cassava wastewater. The treatments of the manipueira by coagulation-flocculation and by microbial consortium decrease the pollution of this effluent before being launched in the water resources / A mandioca (Manihot esculenta) é a terceira cultura mais importante do país na alimentação básica da população. A produção de farinha de mandioca gera um efluente denominado manipueira que contem elevada quantidade de matéria orgânica e cianeto. O objetivo deste trabalho foi investigar a remoção da demanda química de oxigênio (DQO), turbidez e cianeto da manipueira por tratamentos físico-químico e biológico. No tratamento físico-químico por coagulação-floculação, três planejamentos fatoriais completos foram realizados para investigar os fatores: pH, tanino e o polímero sintético auxiliar da floculação (Polipan) sobre as variáveis respostas: DQO, turbidez e cianeto. A eficiência máxima de remoção de DQO foi 91 % a pH 8,0, na presença de tanino 1,0 mL/L e Polipan 0,030 ppm. A maior remoção de turbidez (75 %) foi determinada a pH 8 e tanino 0,8 mL/L, na ausência do Polipan para diminuir os custos do tratamento. Nessas condições, a redução máxima de cianeto foi de 12 %. Nos tratamentos biológicos aeróbios durante 48 h, as eficiências máximas de redução de DQO 88 % e de turbidez 69 % foram determinadas na presença de consórcio microbiano 20 % v/v, cloreto de amônio 5 - 6 % e a pH 8,0. Para os tratamentos físico-químico e biológico, os resultados obtidos mostram que o pH 8 foi fator chave para remoção de compostos orgânicos e do cianeto da manipueira. Os tratamentos da manipueira por coagulação-floculação e por consórcio microbiano diminuem a carga orgânica desse efluente antes de ser lançado nos recursos hídricos
359

Ultra high consistency forming

Karvinen, T. (Tuulikki) 14 May 2019 (has links)
Abstract This study focused on web forming at a 5–10% consistency range, termed Ultra High Consistency (UHC). The study continued work done by Gullichsen with his research groups (1981–2007) and combined it with the HC forming research done by Valmet (HC, 1999–2004). The hypothesis was that by utilizing a rotor to fluidize suspension and a wedge to eliminate the free jet and thus prevent reflocculation, web forming at UHC is feasible at commercial speeds. The research method was experimental. The bulk of the research was conducted at pilot scale. A new UHC headbox was designed and mounted on a pilot former. The key elements of the headbox are the rotor and the wedge. As fluidization forms the base for UHC forming, this was evaluated at the pilot former using image analysis. In addition, fluidization was studied using a laboratory-scale device. Besides basic paper analysis, X-ray microtomography and sheet splitting methods were utilized to analyze the sheet structure. The results show that forming is possible within the focus area, 5–10% consistency and machine speeds of 150–600 m/min, although the operation potential of the UHC former is even wider. The results demonstrate that the wedge is needed for successful UHC forming, but the rotor is not required, providing the flow rate is sufficiently high. This indicates that various forces induced by the flow itself can be adequate to fluidize suspension for forming. The critical Reynolds number of full fluidization was found to be 200–250. The Reynolds numbers were estimated utilizing the linear dependencies found between the apparent viscosity and consistency, using the maximum mean flow velocities inside the headbox, and neglecting the possible rotation of the rotor. The corresponding critical flow velocities at 10% consistency are 12 and 19 m/s for a eucalyptus and pine pulp. The velocities are on average 70 and 60% lower than those given in the literature (40–50 m/s). The results reveal that the fiber orientation of UHC sheets is planar, the floc size of the web increases with consistency, the internal bond increases linearly with the floc size, and the tensile strength appears to decrease with increasing floc size. In consequence, it is postulated that the increase in the out-of-plane strength at the expense of in-plane strength with the consistency increase results from a more flocculated structure. / Tiivistelmä Tutkimus keskittyi rainanmuodostukseen 5–10 % sakeudessa. Sakeusalue nimitettiin ultra korkeaksi (lyhenne UHC). Tämä työ jatkoi Gullichsenin ja hänen tutkimusryhmiensä tutkimustyötä (1981–2007) ja samalla yhdisti sen Valmetin tekemään suursakeusrainaustutkimukseen (HC, 1994–2004). Työn hypoteesina oli, että käyttämällä roottoria massan fluidisoimiseen sekä ns. wedgeä eliminoimaan vapaa suihku ja estämään jälleenflokkaantuminen, rainanmuodostus UHC-sakeudessa on mahdollista kaupallisissa nopeuksissa. Tutkimusmetodi oli kokeellinen. Pääosa tutkimuksesta suoritettiin koekonemittakaavassa. Uusi UHC-perälaatikko suunniteltiin ja asennettiin koeformeille. Perälaatikon pääelementit ovat pyörivä roottori ja wedge. Koska fluidisointi muodostaa UHC-rainauksen perustan, fluidisointia evaluoitiin koekoneella käyttäen kuva-analyysiä sekä tutkittiin lisäksi käyttäen röntgenmikrotomografia ja arkin halkaisu -metodeja. Tulokset osoittavat, että rainaaminen on mahdollista määritellyllä fokusalueella, 5–10 %sakeudessa ja konenopeudella150–600 m/min, joskin UHC-formerin toimintapotentiaali on vieläkin laajempi. Tulokset osoittavat, että wedge tarvitaan onnistuneeseen UHC-muodostamiseen, mutta roottoria ei tarvita, mikäli virtausnopeus on riittävän suuri. Tämä tarkoittaa, että virtauksen aikaansaamat voimat voivat itsessään olla riittäviä massan fluidisoimiseksi rainaamista varten. Täyden fluidisaation kriittisen Reynoldsin luvun havaittiin olevan välillä 200–250. Reynoldsin luvut arvioitiin käyttäen löydettyjä viskositeetin ja sakeuden välisiä lineaarisia riippuvuuksia, päävirtauksen maksiminopeuksia perälaatikossa ja jättäen huomioon ottamatta mahdollinen roottorin pyöriminen. Reynoldsin lukuja vastaavat kriittiset virtausnopeudet 10 % sakeudessa ovat eukalyptus- ja mäntymassalla 12 ja 19 m/s. Nopeudet ovat keskimäärin 70 ja 60 % pienempiä kuin kirjallisuudessa annetut (40–50 m/s). Tulokset osoittavat, että UHC-arkeissa kuituorientaatio on tasomainen, rainan flokkikoko kasvaa sakeuden kasvaessa, palstautumislujuus kasvaa lineaarisesti flokkikoon kanssa ja vetolujuus näyttäisi laskevan flokkikoon kasvaessa. Näin ollen esitetään, että sakeuden kasvaessa tapahtuva palstautumislujuuden kasvu tasolujuuksien kustannuksella johtuu flokkaantuneemmasta rakenteesta.
360

Provozně technický stav objektů separace na úpravnách vody / Operational and Technical Condition of Separation Equipment in Water Treatment Plants

Pešout, Jakub January 2015 (has links)
The goal of this thesis was to determine the operational and technical parameters of the separation objects in water treatment. The first part is a theoretical and provides basic information on this issue. The second part contains the evaluation criteria created by the obtained information for individual objects and gained in practice by personal visits of selected treatment plants of water. In the last part we can find application of these criteria in water treatment in practice. There is also included the final evaluation of the researched condition.

Page generated in 0.132 seconds