Spelling suggestions: "subject:"low injection"" "subject:"low fnjection""
101 |
Vývoj elektroanalytických metod pro detekci cholesterolu a 7-dehydrocholesterolu / Development of electroanalytical methods for detection of cholesterol and 7-dehydrocholesterolBenešová, Lenka January 2018 (has links)
The aim of this Thesis is development of electroanalytical methods for determination of cholesterol and 7-dehydrocholesterol on boron doped diamond electrodes based on electrochemical oxidation of products of acid-induced dehydration reaction. Two approches have been applied, relying on their detection in 0,1 mol.l-1 perchloric acid in acetonitril containing variable water content 0,43 % - 40 %. Cyclic voltammetry revealed substantial difference in oxidation peak pontecials for 7-dehydrocholesterol (+850 mV) and cholesterol (+1500 mV) in 0,1 mol.l-1 perchloric acid in acetonitrile containing 5 % of water. The limit of detection using differential pulse voltammetry were 6,19 µmol.l-1 a 19,2 µmol.l-1 for a mixture of 7-dehydrocholesterol and cholesterol, respectively. For flow injection analysis with amperometric detection (FIA-AD) the water content in run buffer, detection potencial and the distance between the capillary outlet and electrode surface in wall-jet arrangement of amerometric flow-through detection cell were optimized. Achieved detection limits are in range of 0,61 - 3,43 µmol.l-1 depending on the detection potencial and water concent in the run buffer. The developed FIA-AD method was used for determination of a model mixture solution of 7- dehydrocholesterol and cholesterol. Key words...
|
102 |
Detecção piezelétrica não-gravimétrica de boro empregando cristal de quartzo com eletrodo separado e superfície quimicamente modificada / Non-gravimetric piezoelectric detection of boron by using quartz crystal with electrode separated and chemically modified surfaceJesus, Dosil Pereira de 27 August 2003 (has links)
Cristais piezelétricos de quartzo (PQC\'s) com configuração de eletrodo separado e superfície quimicamente modificada foram utilizados para obtenção de um sensor para boro. Uma cela de detecção foi construída, de maneira que um eletrodo de aço inoxidável era mantido a uma pequena distância (0,3 mm) da superfície do PQC, da qual foi removido o eletrodo de ouro original. Foi verificado,por espectroscopia de impedância, medidas de freqüência de oscilação e simulações de espectros de impedância do circuito equivalente da cela, que as propriedades físico-químicas (condutividade, permissividade, densidade e viscosidade) das soluções influenciam de modo diferenciado as freqüências características da cela (ressonância e oscilação). Com o intuito de tomar a superfície sem eletrodo do PQC seletiva a boro, foram experimentadas várias estratégias de modificação química, as quais tinham por objetivo imobilizar polióis (manitol e N-metilglucamina) através de reações de silanização ou deposição de polímeros modificados. Os melhores resultados foram obtidos com o recobrimento do PQC com um filme fino (0,1 a 0,5 µm) de um polímero resultante da modificação da poliepicloridrina com N-metilglucamina (NG). O sensor para boro foi avaliado em um sistema de análises por injeção em fluxo (FIA), em que a solução transportadora era uma solução de etilenodiaminotetraacetato disódico (EDTA) 50 mmol/L (pH 8,5). Observou-se que o mecanismo de resposta desse sensor era predominantemente não-gravimétrico, devido a um aumento de rigidez do filme de recobrimento, causado pela complexação do boro pelos grupos NG ancorados ao polímero. Além disso, o sensor apresenta uma característica bastante interessante que é a retenção do boro, o que possibilita uma diminuição do limite de detecção (LD) em FIA, por meio do aumento do volume de amostra injetado. Para remover o boro do filme sensor, era injetada uma solução de manitol 1 mol/L. Para volumes injetados de 160 e 1000 µL de solução de borato foram alcançados LD\'s de 2 e 0,3 /-lmol/L, respectivamente. É possível detectar até 3 ng do analito presentes no volume de amostra injetado. O efeito de vários prováveis íons interferentes (Mg 2+, Ca2+, Al3+, Cr3+, Mn2+, Fé3+, Co2+, Cu2+, Ni2+, Zn2+, Sn2+, Pb2+, HPO42-, SiO32-, F-, Cl-, SO42-, NO3-, CH3COO-, CO32-, VO3-, Sb(OH)6- AsO4-, AsO3-, SeO3-, SeO4- e Ge(OH) 62-)foram avaliados, porém apenas o íon germanato apresentou significativa interferência, tanto que o sensor também foi considerado adequado para a determinação dessa espécie. A adição de sulfeto à amostra eliminou completamente a interferência do germânio. A não interferência dos íons metálicos é devida à complexação dos mesmos por EDTA presente na solução transportadora. Foi constatado que a presença de polióis, em alta concentração, na amostra afeta a resposta do sensor, uma vez que esses compostos competem com o filme sensor pelo analito. Os resultados obtidos com o sensor encorajaram a construção de um equipamento automatizado de FIA, o qual foi empregado com sucesso na determinação de boro em amostras de águas minerais, sucos de uva, vinagre, vinho e amostra certificada de água de rio. / Piezoelectric quartz crystals (PQC\'s) with electrode-separated configuration and chemically modified surface were used to develop a boron sensor. A detection cell was built in such a way that a stainless-steel electrode was held at a short distance (0.3 mm) from the PQC surface, whose original gold electrode was removed. By using impedance spectroscopy, oscillation frequency measurements, and simulations of impedance spectra of the cell equivalent circuit, it was observed that the physico-chemical properties (conductivity, permissivity, density and viscosity) of the solution affect in different ways the characteristic frequencies of the cell (resonance and oscillation). In order to make the electrodeless PQC surface selective to boron, several chemical modification strategies were tested with the aim of anchoring poliols (manitol and N-metilglucamine) via silanization reactions or deposition of modified polymers. Best results were obtained with PQC coated with a thin film (0.1 to 0.5 µm) of a polymer, which was the product of the polyepichlorohydrin modification with N-methylglucamine (NG). The sensor was evaluated in a flow injection analysis system (FIA), which used a carrier solution containing disodic ethylenediaminetetraacetate (EDTA) 50 mmol/L (pH 8.5). It was observed that the mechanism of detection of this sensor is predominantly nongravimetric, owing to an increase in the stiffness of the covering film, because of the complex formation involving boron and the NG groups, which were incorporated in the polymer. Moreover, the sensor shows an interesting characteristic that is the boron retention, which allows decreasing the limit of detection (LOD) of the FIA method by increasing the injected sample volume. Boron is eluted from the sensor film with 1 mol/L manitol solution. For 160 and 1000 µL volumes of borate solution, the LOD\'s were 2 and 0.3 µmol/L, respectively. It is possible to detect down to 3 ng of boron in the injected sample volume. The effect of several ions (Mg 2+, Ca2+, Al3+, Cr3+, Mn2+, Fé3+, Co2+, Cu2+, Ni2+, Zn2+, Sn2+, Pb2+, HPO42-, SiO32-, F-, Cl-, SO42-, NO3-, CH3COO-, CO32-, VO3-, Sb(OH)6-\' AsO4-, AsO3-, SeO3-, SeO4- e Ge(OH) 62-) was evaluated. Only the germanate ion showed a significant interference, thus, the sensor can also be suitable for this species. However, this interference can be eliminated by the addition of sulfide to the sample. The non-interference of the metal ions is due to the complex formation with EDTA present in the carrier solution. Polyols at high concentration in the samples affect the sensor response, because these compounds compete with the sensor film for the analyte. An automated FIA equipment was built and successfully applied for determination of boron in samples such as mineral water, grape juice, vinegar, wine, and a standard reference material (river water).
|
103 |
Determinação espectrofotométrica de sulfato em águas de chuva em um sistema de análises químicas em fluxo envolvendo troca-iônica / Spectrophotometric determination of sulphate in rain waters using a flow injection system with ion-exchangeGomes, Taciana Figueiredo 05 April 2013 (has links)
Um sistema de análises químicas por injeção em fluxo foi desenvolvido e aplicado à determinação espectrofotométrica de baixas concentrações de sulfato em águas de chuva. O método explora a reação de deslocamento entre o ânion sulfato e o complexo dimetilsulfonazo (III) de bário, Ba-DMSA, com consequente formação do sal pouco solúvel BaSO4. A solução com o complexo Ba-DMSA apresenta alta absortividade molar a 656 nm, e uma diminuição pronunciada na absorbância ocorre na presença de sulfato. Desta forma, o sinal analítico é registrado como pico invertido proporcional à concentração de sulfato na amostra. A presença de altas concentrações de dimetilsulfóxido, DMSO, no reagente favorece a intensidade do sinal analítico, por coordenar as moléculas de água, melhorando a sensibilidade do método. A utilização do tensoativo dodecilsulfato de sódio, SDS, determina também uma melhoria considerável na sensibilidade analítica, pois sua presença no ambiente reacional altera as condições de supersaturação. A sensibilidade e seletividade do procedimento são melhoradas incluindo-se uma etapa de troca iônica em linha, com resina aniônica Dowex 1-X8, para concentração do sulfato e separação dos íons interferentes em potencial. O sistema proposto é robusto e fornece resultados precisos (d.p.r. < 0,01) com frequência analítica de 30 determinações por hora. O consumo de DMSA é de 0,17 \'mü\'mol por determinação. A curva analítica se apresenta linear até 2,0 mg L-1 SO42- e os limites de detecção e de quantificação foram estimados em 0,01 mg L-1 SO42- e 0,04 mg L-1 SO42-. / A flow injection system was developed and applied to the spectrophotometric determination of low concentrations of sulphate in rain waters. The method exploits the displacement reaction involving the sulphate anion and the barium dimethylsulfonazo (III) complex, Ba-DMSA, with consequent formation of the slightly soluble BaSO4 salt. As the Ba-DMSA solution is characterized by a high molar absorptivity at 656 nm, a pronounced absorbance lessening is observed in the presence of sulphate. The analytical signal is then recorded as an inverted peak proportional to the sulphate content in the sample. Presence of dimethylsulphoxide, DMSO, at high concentrations in the reaction medium leads to an enhancement of the analytical signals, coordinating water molecules, thus improving the sensitivity of the method. Addition of the surfactant sodium dodecylsulphate, SDS, results also in a pronounced improvement in sensitivity, as its presence in the reaction medium alters the supersaturation conditions. The sensitivity and selectivity of the method were improved by including an in-line ion exchange mini-column with the anionic resin Dowex 1-X8 into the manifold, for sulphate concentration and separation from potential interfering ions. The proposed system is robust and provides accurate results (R.S.D. <0.01) at an analytical frequency of 30 determinations per hour. About 0.17 \'mü\'mol DMSA are consumed per determination. The analytical curve is linear up to 2.0 mg L-1 SO42- and the detection and quantification limits were estimated as 0.01 mg L-1 SO42- and 0.04 mg L-1 SO42-.
|
104 |
Cristais piezelétricos de quartzo com eletrodos separados e superfície modificada como sensores em fase líquida / Piezoelectric quartz crystals with electrodes separated and modified surface as sensors in liquid mediaJesus, Dosil Pereira de 10 August 1999 (has links)
Esta dissertação descreve a construção e avaliação de um detector para fase líquida utilizando cristal piezelétrico de quartzo (PQC) (3,579545MHz) com a configuração de eletrodos separados. A cela de detecção possui dois eletrodos de latão, que foram posicionados a uma pequena distância (cerca de alguns décimos de milímetros) da superfície do cristal, cujos eletrodos de prata originais foram removidos. Um dos espaços existentes entre os eletrodos e o PQC é preenchido com ar e o outro com um líquido, o qual pode fluir pela cela. Os eletrodos são conectados a um oscilador, cuja freqüência de oscilação é medida através de um freqüencímetro interfaceado a um microcomputador. O detector foi caracterizado, no que se refere à influência da condutividade, densidade, viscosidade e vazão da solução, que flui pela cela, na freqüência de oscilação do PQC. Foi estudado também, com o auxílio de um analisador de impedâncias, o comportamento do módulo e do ângulo de fase da impedância elétrica oferecida pela cela de detecção para a variação das propriedades reológicas, mencionadas anteriormente, da solução. Para testar o arranjo como sensor gravimétrico em um sistema de análise por injeção em fluxo (FIA), foram desenvolvidos dois métodos de silanização da superfície do cristal, um envolvendo o reagente trimetilclorosilano (TCS) e outro utilizando o composto N-(β-aminoetil)-γ-aminopropiltrimetoxisilano (AEAPTS). Os PQCs silanizados com o TCS foram testados para a detecção de compostos orgânicos (clorofórmio e acetona), enquanto os outros cristais, silanizados com AEAPTS, foram utilizados para detecção de íons metálicos. Para esses últimos PQCs notou-se uma boa sensibilidade para íons Cu2+, com os quais conseguiu-se um límite de detecção de aproximadamente 20µM. / This work describes the construction and evaluation of a liquid-phase detector using a piezoelectric quartz crystal (PQC) (3,579545 MHz) with separated electrodes. The detection cell has two brass electrodes, which were placed at a small distance (a tenth of millimeters) from the crystal surface, whose original silver electrodes were removed. One of the gaps between the crystal and the electrodes is filled with air, while the other one is filled with a liquid, which flows through the cell. The electrodes are connected to an oscillator, whose oscillation frequency is measured by a frequency counter interfaced to a microcomputer. The influence of the conductivity, density, viscosity and flow rate of the solution on the PQC oscillation frequency was determined. The behavior of the impedance of the cell and its phase angle as a function of the previously mentioned reologic properties ofthe solution were also studied using an impedance analyzer. Two methods for the silanization of the crystal surface, using trimethylchlorosilane (TCS) and N-(β-aminoethyl)-γ-aminopropyltrimethoxysilane (AEAPTS), were developed to test the assembly as a gravimetric sensor in a flow injection analysis system. The TCS-silanized PQCs were tested for the detection of organic compounds (chloroform and acetone), while the AEAPTS-silanized PQC were used for the detection of metallíc íons. These last PQC showed a good sensibility to Cu2+ ions, for which a limit of detection of about 20µM was obtained.
|
105 |
Desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água / Combining multicommuted flow injection analysis and solid phase photometry for the determination of zinc in pharmaceutical preparation and waterDias, Tuanne dos Reis 25 August 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água. Para implementação do procedimento analítico, todo o sistema foi acoplado a um computador através de uma interface eletrônica. Um software escrito em linguagem QuickBASIC 4.5 permite que o computador efetue o controle da adição das soluções da amostra e do eluente e faça aquisição de dados. O sistema de detecção é constituído de uma cela de fluxo contendo, um LED e um fotodiodo. A geometria da cela de fluxo possibilitava variar o comprimento do caminho óptico. O procedimento para determinação do zinco foi baseado na retenção do analito na fase sólida (TAN-C18), previamente inserida na cela de fluxo, seguido de uma etapa de eluição. Com os parâmetros analíticos otimizados obteve-se resposta linear na faixa de 0,05 a 0,85 mg L-1 (R=0,995), limite detecção de 9,3 \'mü\'g L-1, coeficiente de variação de 1,4% (n=10) e frequência de amostragem de 36 det h-1. O módulo de análise foi aplicado em amostras de produtos farmacêuticos e a exatidão dos resultados foi averiguada comparando com os resultados obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente ICP-OES. Aplicando-se tratamento estatístico apropriado, observou-se que não havia diferença significativa ao nível de confiança de 95 %. Estes resultados comprovam a viabilidade do emprego de fotômetro de LED em fotometria em fase sólida / In this work, it is propose the instrumentation and automatic analytic procedures development using solid phase spectrophotometry for determination of zinc in pharmaceutical preparations and water. For analytic procedure implementation, the whole system was coupled to a computer through an electronic interface. A written software in language QuickBASIC 4.5 allows the computer makes the sample solutions addition control and of eluent and do data acquisition. The detection system is constituted of a flow cell contend, a LED and a photodiode. The flow cell geometry enabled vary the length of the optical path. The procedure for zinc determination was going based in analyte retention in the solid phase (TAN-C18), previously inserted in the flow cell, followed by an elution stage. With the optimized analytic parameters it btained lineal answer in the band of 0,05 to 0,85 mg L-1 (R=0,995), limit detection of 9,3 \'mü\'g L-1, variation coefficient of 1,4% (n=10) and sampling throughput of 36 det h-1. The analysis module was going applied in pharmaceutical preparations samples and the exactness of the results was going ascertained comparing with the results obtained for inductively coupled plasma optic emission spectrometry of with ICP- its. Applying appropriated statistical treatment, it observed that there wasn\'t significant difference to the reliable level of 95 %. These results prove photometer job viability of LED in photometry in solid phase
|
106 |
Desenvolvimento de uma câmara flow-batch com aquecimento direto e de procedimentos analíticos para determinação fotométrica de açúcares redutores em vinhos e de manganês em amostras vegetais / Development of a flow- batch chamber with direct heating and analytical procedures for photometric determination of reducing sugars in wine and manganese in plant samplesBrasil, Marcos Augusto Stolf 27 July 2016 (has links)
Neste trabalho foi desenvolvido um sistema analítico tendo como elemento central uma câmara flow-batch com aquecimento direto e fotômetro acoplado, empregado para determinação de açúcares redutores em vinhos e de manganês em amostras vegetais. A instrumentação foi implementada utilizando o conceito flow-batch e o processo de multicomutação em fluxo. A proposta da câmara com aquecimento direto foi concebida para viabilizar procedimentos analíticos baseados em reações lentas. Adicionalmente, foi realizada a instalação do sistema de detecção fotométrica no próprio corpo da câmara, eliminando a necessidade de resfriamento e transporte da solução para outro componente para monitoramento. Esta estratégia possibilitou a redução das dimensões do sistema e o incremento na frequência de amostragem. O controle do sistema é realizado usando aplicativo desenvolvido na linguagem Visual Basic®, o qual aciona seus componentes e realiza a leitura do sinal analítico através de uma interface. Para propulsão dos fluidos é utilizada uma bomba peristáltica multicanal, ambos dispositivos foram desenvolvidos dentro do presente trabalho. Para a determinação de açúcares redutores em vinho, o método analítico adotado utiliza como reagente cromogênico o hexacianoferrato (III) de potássio em meio alcalino sob aquecimento (50 oC) e leitura em 420 nm. O sistema apresentou uma faixa de resposta linear entre 0,75 e 6% (m/v) frutose (R2= 0,999), limite de detecção de 0,14% (m/v; n = 11), desvio padrão relativo menor que 4%, e frequência analítica de 75 determinações por hora. O procedimento para a determinação de manganês foi baseado na reação de oxidação à permanganato, utilizando como agente oxidante periodato de sódio em meio ácido, aquecimento a 55 oC, e leitura em 530 nm. Após estabelecer as variáveis de controle, o sistema apresentou faixa de resposta linear entre 5 e 30 mg.L-1(R² = 0,997), limite de detecção de 2 mgL-1 (n = 11) Mn2+, desvio padrão relativo de 5%, e frequência analítica de 40 determinações por hora. A exatidão dos resultados foi avaliada aplicando o teste t-Student, onde foram comparados os resultados obtidos com os procedimentos propostos com aqueles obtidos com métodos de referência, e não foram observadas diferenças significativas ao nível de confiança de 95 % / In this work was developed an analytical system, employing a flow-batch chamber with direct heating coupled to a LED based photometer, which was tailored for the determination of reducing sugars in wine and manganese in plant samples. The instrumentation was implemented using the flow-batch concept and multicommutation flow analysis process. The proposed camera with direct heating was designed to enable analytical procedures based on slow reactions. The photometer coupling to the flow-batch chamber body, eliminated the need for a cooling step and as well as solution transportation for another component, where signal would be monitored. This strategy allowed the reduction of the system dimensions, and enabling an increase in sampling frequency. The system control was performed using software developed in Visual Basic ® language, which drove the actives components of the system. For fluid propulsion was used a multichannel peristaltic pump, which was also developed in the present work. For the determination of reducing sugars in wine, the analytical procedure was based on the reaction of potassium hexacyanoferrate (III) in an alkaline medium under heating at 50 ° C, which was monitored at 420 nm. The procedure provided a linear response ranging from 0.75 to 6.00 % (w / v) fructose (R2 = 0.999), a 0.14% limit of detection (w/v, n = 11), a relative standard deviation less than 4.0 %, and an analytical frequency of 75 determination per hour. The procedure for the determination of manganese was based on the permanganate oxidation reaction in acid medium, using sodium periodate solution as an oxidizing reagent. The flow-batch was maintained at 55 ° C, and signal was monitored at 530 nm. After establishing the control variables, the procedure provided a linear response ranging from 5.0 to 30.0 mg L-1 (R2 = 0.997), a detection of limit 2.0 mg L-1 (n = 11) Mn2+, a relative standard deviation of 5.0 % (n = 8) and an analytical frequency of 40 determination per hour. The accuracy of the results was assessed by applying the Student t-test between results obtained employing the proposed procedures and a reference method, and not significant difference at 95 % confidence level was observed
|
107 |
Desenvolvimento de procedimentos analíticos limpos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de cobalto e cádmio em águas / Development of clean analytical procedures employing multicommutation flow analysis systems for photometric determination of cobalt and cadmium in watersGondim, Ticiane Silva 12 December 2016 (has links)
Esse trabalho tem como objetivo o desenvolvimento de procedimentos analíticos automáticos, empregando o processo de multicomutação em fluxo para determinação espectrofotométrica de cobalto e cádmio em amostras de águas. O trabalho envolveu o desenvolvimento dos módulos de análises para implementar os procedimentos analíticos baseados no processo de multicomutação, o sistema de detecção fotométrica empregando LED como fonte de radiação eletromagnética, o software para controle do módulo de análise e para efetuar aquisição de dados. O módulo de análise para determinação de cobalto foi desenvolvido, utilizando mini-bombas solenóide para o bombeamento das soluções. O procedimento analítico foi baseado na catálise do cobalto na reação de oxidação do Tiron pelo peróxido de hidrogênio e com o sistema de detecção espectrofotométrica com LED com emissão em 425 nm. Após os ajustes necessários do módulo de análise o sistema apresentou bom desempenho analítico. Para a determinação de cobalto em águas foram obtidas as seguintes características analíticas: desvio padrão relativo de 0,04 % (n = 13) para uma amostra com 0,5 µgL-1 de Co, faixa de resposta linear entre 0,13 a 1,5 µgL-1 de Co (R = 0,998, n = 3), limite de detecção de 0,06 µgL-1, frequência analítica de 42 determinações por hora e geração de 1,5 mL de resíduo por determinação. Recuperações entre 84 e 114 % foram obtidas com adição de Co (II) nas amostras de águas. O módulo de análise para determinação cádmio foi desenvolvido e otimizado utilizando duas mini-bombas peristálticas para bombeamento das soluções e esvaziamento do percurso, uma válvula solenoide de três vias e três válvulas solenoide de duas vias, uma cela de fluxo com longo caminho óptico (100 mm) e LED com emissão em 520 nm. O procedimento analítico para a determinação do cádmio foi baseado na formação do complexo pelo Cd (II) com o reagente ditizona em meio micelar com o surfactante Triton X100. O procedimento apresentou faixa de resposta linear de 15,0 a 175,0 µgL-1 de Cd (R = 0,997; n = 3), limite de detecção de 12,5 µgL-1, desvio padrão relativo de 0,57 % (n = 10) para uma amostra de 30 µgL-1 e frequência analítica de 43 amostras por hora. Recuperações entre 84 e 112 % foram obtidas com adição de Cd (II) nas amostras de águas. / This work deals with the development of automatic analytical procedures, based on multicommuted flow analysis process for spectrophotometric determination of cobalt and cadmium in water samples. The work involved the development of the analytical modules and the photometric detector using LEDs as electromagnetic radiation sources. The software to control the flow analysis module and to perform data acquisition, were developed using Quick BASIC4.5 as programming language. The analysis module for cobalt determination, employed solenoid mini-pumps for solutions pumping. The procedure was based on the cobalt catalytic effect on the Tiron oxidation by hydrogen peroxide and the photometric detection at 425 nm. After the necessary adjustments of the flow analysis module, the system showed good analytical performance. The following analytical characteristics for determination of cobalt in water were obtained: a relative standard deviation of 0.04% (n = 13) for a standard solution 0.5 µgL-1 Co, a linear response ranging from 0.13 to 1.5 µgL-1 Co (R = 0.998, n = 3), a detection limit of 0.06 µgL-1, analytical frequency of 42 samples determination per hour and a waste generation of 1.5 mL per determination. Recoveries between 84 and 114% were obtained with the addition of Co (II) in water samples. The analytical module for determination of cadmium was developed, using two peristaltic mini-pumps and solenoid valves. The LED based photometer was furnished with a flow cell of long optical path (100 mm) and a LED with maximum emission at 520 nm. The flow analysis module was assembled with ability to perform a closed loop strategy, which was implemented to improve sensitivity. The analytical procedure for the determination of cadmium was based on reaction of Cd (II) with dithizone in a micelle medium with the surfactant Triton X-100. The procedure showed a linear response ranging from 15.0 to 175.0 µgL-1 Cd (R = 0.997; n = 3), detection limit of 12.5 µgL-1, RSD 0.57% (n = 10) for a sample of 30 µgL-1 and analytical frequency of 43 samples per hour. Recoveries between 84 and 112% were obtained with addition of Cd (II) in water samples.
|
108 |
Desenvolvimento de instrumentação e procedimentos automáticos para determinação de arsênio e fluoreto em águas empregando multicomutação em fluxo e detecção fotométrica / Development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutaion and photometric detectionTeixeira, Marcelo Alves 12 May 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de fluoreto e arsênio em águas empregando o conceito de multicomutação em fluxo e detecção fotométrica. Na determinação de fluoreto, o controle dos dispositivos foi realizado empregando um computador, programado em QuickBasic 4.5. O fotômetro desenvolvido utilizava um fotodetector (OPT301), uma cela de fluxo com 60 mm de caminho óptico e um LED (\'lambda\' = 525 nm), usado como fonte de radiação. Os sinais gerados pelo fotômetro foram convertidos para digital empregando um multímetro digital, que os transferia para o computador através da interface serial RS-232. O procedimento para a determinação de fluoreto foi baseado no método de zircônio/ vermelho de alizarina S, onde o fluoreto retira o zircônio da estrutura metal ligante formando um complexo incolor. Após a seleção das variáveis de controle, o procedimento proposto apresentou resposta linear na faixa de 0,25 a 1,75 mg L-1 (LD = 0,06 mg L-1), desvio relativo menor que 3,5%, freqüência de amostragem de 45 h-1. No sistema para determinação de arsênio em águas, o controle do módulo de análise foi realizado utilizando um microcontrolador da série PIC 18F2553, o qual contém um conversor A/D interno de 12 bits de resolução e capacidade de operar com taxa de amostragem de até 100.000 s-1. O mesmo recebia os parâmetros de controle por um computador via USB 2.0, que utilizava a mesma interface para transferir os dados provenientes do fotômetro. O software para essa comunicação foi escrito em Delphi 7.0 e a linguagem C foi utilizada para a programação do microcontrolador. Como sistema de detecção foi o mesmo empregado na determinação de fluoreto, utilizando um LED (\'lambda\' = 625 nm) como fonte de radiação. O procedimento proposto para a determinação de arsênio foi baseado na reação do arsênio inorgânico com boro-hidreto, onde a arsina formada reagia com azul de metileno em meio micelar. A descoloração da solução de azul de metileno era proporcional à concentração de arsênio presente na amostra. A procedimento proposto apresentou resposta linear na faixa de 2,5 a 40 \'mü\'g L-1 (r = -0,995), limite de detecção de 0,3 \'mü\'g L-1, desvio relativo menor que 6,5 %, freqüência de amostragem de 25 h-1. / The development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutation and photometric detection were proposed. For fluoride determination, the system was controlled by a microcomputer equipped with MS-Dos environment and running a software written in Quick Basic 4.5. It was used a homemade photometric detector OPT301, a 60 mm pathway flow cell, and a light emitting diode (\'lambda\' = 525 nm) as light source. Data acquisition was performed by using a digital multimeter and a microcomputer with RS- 232 serial interface. The method was based on a complexation reaction between fluoride and alizarin red S, where the fluoride takes out the zircon from the metal-binding moieties resulting in color bleaching. After optimization of parameters, the procedure provided linear response in the 0.25 to 1.75 mg L-1 range, limit of detection of 0.06 mg L- 1, coefficient of variation lower than 3.5 %, and sample throughput of 45 determinations per hour. For arsenic determination, the control module was performed by using a PIC 18F2553 microcontroller equipped with a 12 bits resolving power A/D internal converter, working at 100,000 sampling per second rate. Data acquisition was performed by a microcomputer equipped with Windows environment and running a software written in Delphi 7.0. A LED (\'lambda\' = 625 nm), as radiation source, was used for As determinations by using the same detection system used for fluoride determination. The method for As determination was based on the color bleaching of methylene blue in micellar media by AsH3 produced from inorganic As and NaBH4. The color bleaching of methylene blue was proportional to As concentration in the sample. The proposed method provided linear response in the 2.5 to 40 \'mü\'g L-1 range, limit of detection of 0,3 \'mü\'g L-1, coefficient of variation lower than 6.5 %, and sample throughput of 25 determinations per hour.
|
109 |
Determinação espectrofotométrica catalítica de molibdênio e ferro explorando calibração multivariada em um sistema de análises químicas em fluxo / Catalytic spectrophotometric determination of Mo(VI) and Fe(III) exploiting multivariate calibration implemented in a flow systemOliveira, Eliézer de 30 November 2015 (has links)
Os efeitos catalíticos de Mo(VI) e Fe(III) na oxidação de iodeto por peróxido de hidrogênio foram explorados visando à determinação simultânea destes. Diferenças nas taxas de reação foram alcançadas através do estabelecimento de duas zonas reacionais distintas para alteração das cinéticas reacionais. Para isto, foi projetado um sistema de análises por injeção em fluxo que permite a inserção de duas alíquotas de amostra, sendo adicionado ácido sulfúrico em uma destas com formação de uma zona de amostra complexa. Cada elemento de fluido desta zona é caracterizado por composição química, tempo de residência e taxa de reação específicas. Os principais parâmetros que afetam a taxa reacional, tais como concentração dos reagentes, comprimento do reator e vazão total, dentre outros, foram avaliados buscando melhoria na sensibilidade e discriminação cinética entre os analitos. Os comprimentos das alças de amostragem e da bobina separadora foram avaliados construindo-se modelos matemáticos visando máxima discriminação nas previsões para os analitos. Os modelos foram construídos a partir da ferramenta quimiométrica PLS (Partial Least Squares) utilizando os dados gerados por medidas de máximos e mínimos ao longo da zona de amostra. O conjunto de calibração era composto por misturas de Mo(VI) e Fe(III) na faixa de concentrações 6,2 - 50,0 ?g L-1 e 0,5 - 7,0 mg L-1, respectivamente. O modelo selecionado apresenta boa habilidade de previsão com valores de RMSEP estimados como 0,67 ?g L-1 para Mo(VI) e 0,21 mg L-1 para Fe(III). Recuperações entre 85 e 114% foram obtidas para amostras de águas naturais. O sistema proposto apresenta estabilidade física, boa repetibilidade entre as leituras (d. p. r. < 2 %), velocidade analítica de 31 h-1 e consumo de 54 mg de iodeto de potássio e 0,30 mg de peróxido de hidrogênio por amostra / The catalytic effects of Mo(VI) and Fe(III) in the oxidation of iodide by hydrogen peroxide were exploited aiming at their simultaneous determination. Differences in reaction rates were achieved by establishing of two distinct reactions zones to modify the reaction kinetics involved. To this end, a flow injection system allowing insertion of two sample aliquots was designed, and sulfuric acid was added to one of the aliquots. A complex sample zone was then established. Each fluid element of this zone was characterized by a given chemical composition, residence time and reaction rate. The main parameters affecting the reaction rate, such as reagent concentrations, analytical path length and total flow rate, among others, were evaluated for improving sensitivity and analyte kinetic discrimination. Influences of sampling loop lengths and distance between initial plugs were studied, and mathematical models were constructed aiming at improved discrimination in prediction of analytes. The models were constructed from the PLS (Partial Least Squares) chemometric tool using data generated by measurements performed on sample zone regions with maximum and minimum local concentrations. The calibration set consisted of Mo(VI) and Fe(III) mixtures in concentration ranges of 6.2 - 50.0 ?g L-1 and 0.5 - 7.0 mg L-1, respectively. The selected model is characterized by good prediction ability prediction, as RMSEP values were estimated as 0.67 ?g L-1 for Mo(VI) and 0.21 mg L-1 for Fe(III), respectively. Recoveries within the 85 - 114% range were obtained for natural waters. The proposed system presents physical stability and favorable characteristics of measurement repeatability (r.s.d.<2%), sampling rate (31 h-1) and reagent consumption (54 mg of KI and 0.30 mg H2O2 per sample)
|
110 |
Sistema de análise em fluxo empregando geração eletroquímica de reagente e detecção biamperométrica para a determinação de sulfitoPAULA, Nattany Tayany Gomes de 12 March 2015 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2017-02-15T14:00:25Z
No. of bitstreams: 1
Nattany Tayany Gomes de Paula.pdf: 885461 bytes, checksum: 787ab63496a1306c113ee5c12e2dac92 (MD5) / Made available in DSpace on 2017-02-15T14:00:25Z (GMT). No. of bitstreams: 1
Nattany Tayany Gomes de Paula.pdf: 885461 bytes, checksum: 787ab63496a1306c113ee5c12e2dac92 (MD5)
Previous issue date: 2015-03-12 / Sulfites are considered food additives that after chemical reaction releasing sulfur dioxide (SO2), sulfite ion (SO32-), or bisulfite ion (HSO3-). These additives act as antioxidants in food, in the control of bacterial growth and enzymatic and non-enzymatic browning reactions during processing and storage. Although widely used in the food industry, the use of sulfite as a preservative causes some problems, reducing the nutritional quality of foods processed and in some cases are caused adverse effects to human health. In this work it is proposed to determine sulfite in samples of processed juices and wines through an analytical flow system with biamperometric detection. The system was built employing a peristaltic pump, proportional injector, a Gas Diffusion Cell (GDC) and Reagent Generation Cell (RGC) and polyethylene tubes with an internal diameter of 0.8 mm for making the analytical path. The RGC was coupled to a potentiostat for applying current to the electrochemical generation of triiodide ions. For detection it was used a biamperometric detector, adapted to a coulometer for applying the constant potential. For the data acquisition and processing was performed using a software developed in Lab View® language. The analysis method was based on a redox reaction between the I3- ions SO32- and providing a decrease of the generated current by the pair and this decrease in the signal is proportional to the concentration of SO32- ions. After the system optimization, the proposed procedure was operated with KI concentrations of 0.25 mol L-1, HCl 1.0 mol L-1, Na2SO4 and 0.1 mol L-1, with 0.25 mA current applied in RGC and the length of the sampling loop was of 20 cm. In the proposed procedure, a linear response was obtained between 1 and 12 mg L-1 of sulfite E = - (0,2371 ± 0,0028) C + (6,7097 ± 0,0182), R = -0,9997), LD = 0,26 mg L-1 and LQ = 0,86 mg L-1, relative standard deviation less than 2% (n = 10), with sampling frequency of 40 h−1. Potential interfering studies demonstrated the selectivity of the proposed method. Addition and recovery tests with samples of juices and wines were performed to give results of recovery between 91.63 and 110.34%, demonstrating the possibility of operation of the proposed procedure in real samples. / Os agentes sulfitantes ou sulfitos são considerados aditivos alimentares que, após reação química, liberam dióxido de enxofre (SO2), íon sulfito (SO32-) ou íon bissulfito (HSO3-). Estes aditivos são agentes multifuncionais e atuam como antioxidantes em alimentos, no controle do crescimento bacteriano e de reações (enzimáticas e não enzimáticas) de escurecimento durante o processamento e estocagem. Mesmo sendo muito utilizado na indústria de alimentos, o emprego de sulfitos como conservantes provoca alguns problemas, reduzindo a qualidade nutricional dos alimentos tratados e em alguns casos são provocados efeitos adversos à saúde humana. Neste trabalho propõe-se determinar sulfitos em amostras de sucos industrializados e vinhos empregando um sistema de análise em fluxo com detecção biamperométrica. O sistema foi construído empregando-se uma Bomba Peristáltica, um Injetor Proporcional, uma Câmara de Difusão Gasosa (CDG) e uma Câmara de Geração de Reagente (CGR). A CGR foi acoplada a um potenciostato para a aplicação de corrente necessária para a geração eletroquímica de íons triiodeto. Para detecção foi utilizado um detector biamperométrico. Para o tratamento e aquisição de dados, foi utilizado um software desenvolvido em linguagem Lab View®. A metodologia de análise foi baseada em uma reação de oxirredução entre os íons SO32- e I3-, que proporciona uma diminuição da corrente biamperométrica gerada pelo par redox I3-/I-, sendo essa diminuição de corrente proporcional a concentração de íons SO32-. Após a otimização do procedimento proposto obteve-se as melhores condições: 0,25 mol L-1 de KI, 1,0 mol L-1 de HCl, 0,1 mol L-1 de Na2SO4, corrente de 0,25 mA aplicada na CGR e volume de amostra de 100 μL. Nestas condições, obteve-se uma resposta linear entre 1 e 12 mg L-1 de sulfito (I = - (0,2371 ± 0,0028) C + (6,7097 ± 0,0182), R = -0,9997), LD = 0,26 mg L-1 e LQ = 0,86 mg L-1, desvio padrão relativo menor que 2% (n = 10), com frequência de amostragem de 40 determinações por hora. Estudos de potenciais interferentes demonstraram a seletividade do método proposto. Testes de adição e recuperação com amostras de sucos e vinhos foram realizados, obtendo-se resultados de recuperação entre 91,63 e 110,34%, demonstrando a possibilidade de operação do procedimento proposto em amostras reais.
|
Page generated in 0.106 seconds