• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 446
  • 11
  • 10
  • 10
  • 10
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 463
  • 168
  • 103
  • 96
  • 75
  • 66
  • 61
  • 60
  • 54
  • 53
  • 53
  • 47
  • 46
  • 45
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Análise da resistência à fratura de dentes caninos de cães (Canis familiaris) submetidos a restaurações biológicas: experimento in vitro / Fracture strength analysis of canine teeth restored biologically: in vitro>/I> study

Corrêa, Herbert Lima 01 July 2003 (has links)
Para avaliação da resistência à fratura de dentes caninos de cães restaurados biologicamente (colagem de fragmento) foram utilizados 50 dentes distribuídos em cinco grupos de dez dentes cada. Com exceção dos dentes do grupo 1, que serviram de controle, os demais foram seccionados e posteriormente restaurados com o próprio fragmento (colagem) através de diferentes protocolos: Grupo 2: pino fundido (Níquel-Cromo) e cimento resinoso; Grupo 3: pino de fibra de vidro e cimento resinoso; Grupo 4: pino de fibra de carbono e cimento resinoso; Grupo 5: não foram utilizados pinos, apenas adesivo e resina composta fotopolimerizável (colagem simples). Os dentes foram, então, submetidos a teste de resistência através da aplicação de uma carga perpendicular ao longo eixo do dente na sua face lingual. Os resultados permitiram concluir que a utilização de pinos intra-radiculares teve influência significativa na resistência à fratura dos dentes colados quando comparada ao grupo de colagem simples, no entanto, foi de 45,4 %, 14,2%, 11,4% (respectivamente para os grupos 2, 3 e 4) da resistência necessária para fraturar os dentes íntegros, enquanto para o grupo 5 foi de 7,0 %. Dessa forma, nas condições deste experimento, os protocolos nos quais se utilizam pinos intra-radiculares parecem ser os mais indicados para colagem de dentes caninos fraturados. / To determine the fracture strength of canine teeth of dogs restored biologically (bondind of tooth fragment), 50 teeth were used and distributed in 5 groups of ten teeth each. The group 1 was the control (intact teeth). In the other groups the teeth were sectioned and bonded under different protocols: Group 2: cast post (Nickel-chromium) and resin luting cement; Group 3: Fiberglass post and resin luting cement; Group 4: Carbon fiber post and resin luting cement; Group 5: no post was used, only dentin adhesive and light-cured composite resin (simple bonding). The teeth were submitted to fracture strength test through the application of a perpendicular load to the tooth long axis in its lingual face. The results showed that the use of post improved significant fracture strength of bonding teeth when compared to the group of simple bonding, however this was 45.4%, 14.2%, 11.4% (respectively for the groups 2, 3 and 4) of the load necessary to fracture the sound teeth, whereas was it 7.0% in group 5. In these experimental conditions, the protocols where posts are used seem to be more indicated to bonding tooth fragment in fractured canine tooth.
332

Caracterização miofuncional clínica e eletromiográfica de pacientes adultos com trauma de face / Oral-motor and electromyographic caracterization of patients submitted to open and closed reductions for facial fractures

Silva, Amanda Pagliotto da 03 December 2015 (has links)
Objetivo: realizar a caracterização do sistema miofuncional orofacial de indivíduos adultos com fraturas de face, que foram submetidos à procedimentos cirúrgicos distintos para a correção das fraturas (redução aberta e fechada). Métodos: 57 participantes divididos em três grupos: G1- composto por 19 indivíduos submetidos a redução aberta de pelo menos uma das fraturas faciais; G2- composto por 19 indivíduos submetidos a redução fechada da fratura; GC - 19 indivíduos voluntários saudáveis, sem alterações no sistema miofuncional orofacial. Todos os participantes foram submetidos à avaliação que consistiu na aplicação de um protocolo clínico para a avaliação da motricidade orofacial, a amplitude dos movimentos mandibulares e a avaliação da musculatura mastigatória por meio da eletromiografia de superfície (EMGs). Resultados: os resultados indicaram que para avaliação clínica da motricidade orofacial, ambos os grupos com fratura de face se diferenciaram do grupo controle, apresentando prejuízo na mobilidade dos órgãos fonoarticulatórios e nas funções de mastigação e deglutição. Os grupos com fratura de face não se diferenciaram neste item da avaliação. Quanto às medidas de amplitude mandibular, os grupos com fratura de face também se diferenciaram do grupo controle, apresentando maior restrição da mobilidade mandibular. Nesta etapa da avaliação, o grupo submetido à redução fechada da fratura apresentou maior amplitude de movimentos, se comparado ao grupo submetido à redução aberta da mesma, principalmente para a medida de abertura oral máxima. Na avaliação eletromiográfica dos músculos mastigatórios, o grupo submetido à redução aberta da fratura apresentou menor ativação muscular se comparado aos demais grupos. Ambos os grupos com fraturas de face se diferenciaram significantemente do grupo controle quando considerado o índice de assimetria do músculo masseter, apresentando funcionamento muscular mais assimétrico na tarefa de máxima intercuspidação dentária. Conclusão: Os pacientes com trauma de face apresentam alterações significativas em postura, mobilidade, funções orofaciais, amplitude mandibular e na atividade eletromiográfica. O tipo de tratamento médico não influenciou os resultados da funcionalidade muscular no período de até seis meses após a correção da fratura / Purpose: to characterize the oral-motor sytem of adults with facial factures, comparing the performance of individuals submitted to open and closed surgical treatment. Methods: 57 adults divided into three groups: G1 - 19 individuals submitted to open surgery for the correction of at least one of the facial fractures; G2 - 19 individuals submitted to closed surgery for the correction of facial fractures; GC - 19 voluntary healthy individuals, with no alterations of the orofacial myofunctional system. All participants underwent the same assessment: clinical assessment of the orofacial myofunctional system; evaluation of the mandibular range of movements; and surface electromyography (sEMG) of the masticatory muscles. Results: the results indicated that both groups with facial fractures presented significant differences when compared to the control group, in terms of the mobility of the oral-motor organs, mastication and swallowing. However, the groups with facial fractures did not differ in performance. Regarding the measurements obtained for the mandibular movements, both groups with facial fractures presented significant differences when compared to the control group, indicating greater restrictions in mandibular movements. The group submitted to closed surgery presented better range of movements when compared to the group submitted to open surgery, especially when considering the measurement of maximal mandibular opening. When analyzing the results of the sEMG, the group submitted to open surgery presented lower muscle activation when compared to the other two groups. Both groups with facial fractures differed significantly from the control group when considering the index of asymmetry for the masseter muscle, presenting a more asymmetrical muscle function during the task of maximum voluntary teeth clenching. Conclusion: Patients with facial trauma present significant deficits in posture, mobility and function of the oral motor system. The type of medical treatment did not have an influence on the results of muscle function during the first six months after fracture reduction
333

Avaliação da reparação e indicadores de desnutrição de ratos submetidos à fratura de côndilo mandibular e com desnutrição protéica / Evaluation of healing and undernutrition indicatives of rats submitted to mandibular condyle fracture and with protein undernutrition

Rodrigues, Lucimar 10 February 2009 (has links)
Este trabalho avaliou a reparação e indicadores de desnutrição de ratos submetidos à fratura unilateral de côndilo mandibular e com desnutrição protéica (8% de proteína com suplemento de vitaminas e minerais). Foram utilizados 45 Rattus norvegicus Wistar, adultos machos, distribuídos em 3 grupos de 15 animais: grupo fraturado, submetido à fratura de côndilo, sem alteração de dieta (23% de proteínas); grupo fraturado desnutrido, submetido à dieta hipoprotéica por 30 dias e posterior fratura condilar; grupo desnutrido, com dieta hipoprotéica prévia por 30 dias e mantida até o final do experimento, sem fratura de côndilo. Foi documentada a quantidade de ingestão de ração e água, feita a avaliação do peso e obtido o coeficiente de eficácia alimentar (CEA). Os animais foram sacrificados nos períodos de 24 horas e 7, 15, 30 e 90 dias pós-operatório. Foram realizados os seguintes testes bioquímicos do sangue: proteínas totais, albumina sérica, cálcio sérico, fosfatase alcalina, ferro sérico e creatinina sérica; e o leucograma. A seguir, foram feitas mensurações cefalométicas por radiografias da maxila e da mandíbula. O estudo histológico compreendeu a avaliação do local da fratura e da articulação temporomandibular. Os valores numéricos foram submetidos a análises estatísticas. O consumo de ração e água foi maior no grupo fraturado desnutrido, na maioria dos períodos. Os valores do CEA foram baixos principalmente nos períodos iniciais, sendo mais significativos para o grupo fraturado desnutrido. Houve pouco ganho de peso nos períodos iniciais, exceto no grupo fraturado desnutrido que apresentou perdas significativas, havendo recuperação de peso nos demais períodos, significativamente menor neste grupo. Os testes de bioquímica do sangue mostraram queda, principalmente nos períodos iniciais, para os valores de proteínas totais e albumina, bem como para cálcio sérico em todos os períodos, significante para o grupo fraturado desnutrido. O leucograma mostrou aumento, principalmente nos períodos iniciais, de leucócitos, linfócitos e neutrófilos, mais significativo no grupo fraturado desnutrido. Houve desvio da linha média mandibular em relação à linha média maxilar, significante para o grupo fraturado desnutrido, bem como assimetria de maxila e mandíbula, em especial no período final do experimento. A análise histológica mostrou que a desnutrição protéica levou à atrofia da fibrocartilagem do côndilo. A fratura sob desnutrição comprometeu a formação do calo ósseo, bem como houve anquilose fibrosa. Foi concluído que a fratura de côndilo mandibular em ratos com desnutrição protéica promoveu alterações negativas nos valores de proteínas totais, albumina e cálcio sérico, leucocitose, bem como comprometeu a formação do calo ósseo e induziu atrofia da fibrocartilagem e anquilose fibrosa. / This study evaluated the healing and undernutrition indicatives of rats submitted to mandibular condyle fracture and with protein undernutrition (8% of protein with vitamin and minerals supplement). Forty-five adult male Wistar Rattus norvegicus were used and distributed in 3 groups of 15 animals: fracture group, submitted to condylar fracture with no changes in diet (23% of proteins); undernutrition fracture group, submitted to hypoproteic diet by 30 days and later to condylar fracture; undernutrition group, with previous hypoproteic diet by 30 days, kept until the end of experiment, without condylar fracture. The amounts of feed and water intake were registered, as well as body weight and food efficiency ratio (FER) were obtained. Animals were sacrificed at 24 hours and 7, 15, 30 and 90 days postoperatively. The following blood biochemical tests were made: total serum proteins, serum albumin, serum calcium, alkaline phosphatase, serum iron, and serum creatinine; and also white blood count. Subsequently, cephalometric mensurations by radiograms of the maxilla and mandible were made. Histological study comprised fracture site and temporomandibular joint evaluations. Numerical values were submitted to statistical analyses. Feed and water intake were higher in undernutrition fracture group, in most of periods. Values of FER were low, in special in the initial periods, being more significative to undernutrition fracture group. There was low gain of weight in the initial periods, but undernutrition fracture group which presented significative loss of weight, with recovering of weight in the remaining periods, significatively lower in this group. Blood biochemical tests showed decrease, mainly in the initial periods, of the values of total serum proteins and serum albumin, as well as serum calcium in all the periods, significative to undernutrition fracture group. White blood count showed increase, in special in the initial periods, of leukocytes, lymphocytes and neutrophils, more significative in undernutrition fracture group. There was deviation of the median line of the mandible relative to the median line of the maxilla, significative to undernutrition fracture group, as well as asymmetry of the maxilla and mandible, in special in the final period of experiment. Histological analysis showed that proteic undernutrition lead to atrophy of condylar fibrocartilage. Fracture in undernutrition impaired callus formation, as well as there was fibrous ankylosis. It was concluded that mandibular condyle fracture in rats with proteic undernutrition promoted negative alterations in values of total proteins, albumin and serum calcium, leukocytosis, as well as impaired callus formation, and induced atrophy of condylar fibrocartilage and fibrous ankylosis.
334

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Roberto Bombonatti 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
335

Aplicação dos elementos finitos singulares híbridos na mecânica da fratura linear elástica bidimensional.

Jorge Luiz Cerqueira Fernandes 00 December 2002 (has links)
Este trabalho trata da aplicação do conceito de elemento singular híbrido na determinação dos fatores de intensidade de tensão e da tensão T em sólidos isotrópicos, sujeitos a um estado plano de tensões ou a um estado plano de deformações. Inicialmente é feita uma breve revisão da aplicação do método de elementos finitos na mecânica da fratura, ressaltando a necessidade da utilização dos elementos finitos singulares. Todas as etapas envolvidas na formulação do superelemento singular híbrido de equilíbrio, introduzido por Tong et al. (85), são detalhadamente desenvolvidas. A formulação abrange superelementos com funções de interpolação lineares, bilineares e quadráticas, possibilitando a sua utilização com vários elementos convencionais formulados pelo método dos deslocamentos. Um código computacional foi implementado e o método aplicado na análise de várias configurações típicas de placas retangulares com trincas, inclusive um painel com reforçadores. Os resultados obtidos apresentam boa concordância com dados da literatura. Por último, é realizada uma comparação com métodos que utilizam os elementos finitos distorcidos ("quarter-point elements"), confirmando a maior precisão dos resultados obtidos com o uso dos elementos singulares híbridos.
336

Estudo experimental de fratura em diafragmas metálicos de túneis de vento hipersônicos usinados com laser a fibra pulsado.

Samoel Mirachi 27 August 2010 (has links)
Túneis de vento são ferramentas fundamentais para o estudo da dinâmica dos gases e possibilitam testes de comportamento aerodinâmico de protótipos em regime de escoamento hipersônico. Um tubo de choque é constituído basicamente de uma seção de alta pressão (Driver) e outra de baixa pressão (Driven) separadas por um diafragma de ruptura metálico que atua como uma válvula de pressão rápida conectando ambas as seções. Se acrescentar uma tubeira e um tanque de exaustão, este tubo de choque se torna um túnel de vento hipersônico. A pressão de ruptura do diafragma determina a velocidade de escoamento do gás na seção de baixa pressão e que pode variar desde Mach 6 até Mach 25 no túnel de vento hipersônico instalado no IEAv. Usualmente, o controle da pressão de ruptura é obtido usinando-se microranhuras em forma de cruz na superfície do diafragma metálico que tem por função direcionar a sua fratura e promover sua rápida abertura. A usinagem mecânica das microranhuras é um processo lento e que, com o desgaste natural da ferramenta de corte, apresenta sérios problemas de manutenção das dimensões das microranhuras. Como forma de solucionar este problema é proposta e desenvolvida neste trabalho uma nova técnica de fabricação de microranhuras em diafragmas metálicos utilizando-se um laser pulsado de baixa potência média e com alta taxa de repetição de pulsos. O processo de usinagem a laser permite a obtenção de microranhuras com dimensões reprodutíveis e controláveis com precisão inferior a 0,1 mm, o que favorece o controle preciso da pressão de ruptura do túnel de vento. A gravação das microranhuras foi efetuada em chapas finas de aço AISI 1020 utilizando um laser a fibra de itérbio pulsado com uma potência média de 20 W, largura de pulso de 150 ns e taxa de repetição de 20 kHz. Com este laser foram obtidas microranhuras com larguras inferiores a 0,05 mm e profundidade precisamente controlada entre 0,3 mm e 0,7 mm, controlando com uma mesa CNC com velocidade de usinagem entre 0,5 mm/s e 8,0 mm/s. Os testes de ruptura dos diafragmas de aço foram realizados em um dispositivo hidráulico acionado por pistão desenvolvido neste trabalho e também no túnel de vento hipersônico T1 do IEAv. A pressão de ruptura dos diafragmas obtida com o dispositivo hidráulico foram equivalentes àquela obtida nos testes efetuados no T1. Dessa forma mostra-se ser possível desenvolver e qualificar os diafragmas sem a necessidade de testes no T1, reduzindo o seu custo de fabricação. Com a técnica de gravação a laser utilizada no trabalho a pressão de ruptura no túnel de vento hipersônico pode ser controlada precisamente no intervalo de pressão entre 30 bar e 120 bar, com grande redução no tempo de fabricação e sem perda de reprodutibilidade.
337

Elementos finitos na mecânica de fratura de cascas cilíndricas

Afonso Santos Verges 01 June 1993 (has links)
Determinação do fator intensidade de tensões numa casca cilíndrica com trinca longitudinal, considerando a Mecânica da fratura linear elástica e utilizando o método de Elementos Finitos. Na extremidade da trinca foi utilizado um elemento distorcido (quarter-point element) retangular.
338

Análise fractográfica de compósitos poliméricos estruturais.

Leandro Augusto Lemos Franco 00 December 2003 (has links)
O uso de materiais compósitos poliméricos na construção de aeronaves é cada vez mais intenso. Com isto, a possibilidade de ocorrer uma falha em serviço de uma peça fabricada com este material torna-se cada vez maior. A análise de falhas de materiais compósitos ainda é um tema pouco explorado, principalmente no Brasil, porém tem se tornado cada vez mais importante, em apoio à área de prevenção e investigação de acidentes aeronáuticos. Este trabalho visa caracterizar as fraturas de laminados de fita unidirecional de fibra de carbono de módulo intermediário com resina epóxi modificada, tipo 8552, em ensaios mecânicos de tração longitudinal e transversal e cisalhamento interlaminar. Parte das amostras de laminados foi submetida ao condicionamento higrotérmico, em situação de temperatura e umidade controladas, de modo a determinar a influência desses parâmetros nas propriedades mecânicas e na fratura dos laminados. Foram também estudadas algumas famílias de laminados cruzados de fibras de carbono com os sistemas de resinas epóxi F155 e F584 e tecidos de fibras de aramida e vidro, impregnados com os sistemas epóxi F155 e F161, respectivamente. Estas famílias foram ensaiadas em tração e compressão. As observações das fraturas das amostras ensaiadas mecanicamente foram realizadas com o auxílio da microscopia eletrônica de varredura, microscopia óptica e estereoscopia. A comparação dos resultados mostra que o condicionamento higrotérmico afeta de maneira significativa a resina, com pouca influência nas fibras e na interface fibra/resina. As fraturas, em geral, apresentam pouca diferença em função do condicionamento. A fratura das amostras ensaiadas em tração longitudinal é a que apresenta os aspectos mais interessantes do ponto de vista fractográfico. As amostras não submetidas ao condicionamento higrotérmico (amostras secas) revelam a importância da rigidez da fibra na fratura. A comparação das superfícies de fratura, obtidas sob um mesmo ensaio mecânico, mostra que as fibras menos rígidas apresentam maior influência na fratura. O tipo e o arranjo do reforço também apresentam influência nas superfícies de fratura dos laminados ensaiados mecanicamente.
339

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Bombonatti, Roberto 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
340

Prevalência e fatores de risco para fraturas vertebrais em idosos da comunidade / Prevalence and risk factors of vertebral fractures in communitydwelling elderly

Lopes, Jaqueline Barros 08 January 2010 (has links)
Objetivo: Estimar a prevalência de fraturas vertebrais investigando os fatores de risco associados com esta última condição em idosos brasileiros da comunidade. Métodos: Este estudo de corte transversal incluiu 769 indivíduos idosos com 65 anos ou mais (462 mulheres e 307 homens) residentes em São Paulo, Brasil. Radiografias de coluna torácica e lombar foram obtidas e fraturas vertebrais foram avaliadas usando o método semiquantitativo de Genant. Densidade mineral óssea (DMO) foi mensurada por DXA e parametros bioquímicos foram também avaliados. Mulheres e homens foram analisados separadamente, e cada gênero foi dividido em 2 grupos com base na presença de fraturas vertebrais. Resultados: A prevalência de fraturas vertebrais foi de 16,7% (95% CI 13,3-20,1) nas mulheres e 21,2% (95% CI 16,6-25,7) nos homens. Análise de regressão logística usando as variáveis significantes na análise univariada no grupo feminino mostrou que a idade (OR=1,12, 95% CI 1,06-1,18; p<0,001) e o Tscore do colo femoral (OR=0,61, 95% CI 0,46-0,88; p=0,006) foram fatores de risco independentes na predição de fraturas vertebrais. No grupo masculino, a análise de regressão logística demonstrou que a condição de caidor crônico (OR=2,54 95% CI 1,1-5,9; p=0,031) e T-score do colo femoral (OR=0,72, 95% CI 0,53-0,96; p=0,025) foram independentes parâmetros na predição de fraturas vertebrais. Conclusão: Nossos resultados sugerem que fraturas vertebrais são comuns em idosos brasileiros e que o T-score do colo femoral baixo foi um importante fator de risco para esta condição em ambos homens e mulheres. Idade também foi significantemente correlacionada com a presença de fraturas vertebrais em mulheres, e a condição de caidor crônico foi correlacionada com fraturas vertebrais em homens. / Purpose: To estimate the prevalence of radiographic vertebral fracture and investigate factors associated with this condition in Brazilian communitydwelling elderly. Methods: This cross sectional study included 769 elderly subjects 65 years old and over (462 women and 307 men) living in São Paulo, Brazil. Thoracic and lumbar spine radiographs were obtained and vertebral fractures were evaluated using Genant´s semi-quantitative method. Bone mineral density (BMD) was measured by DXA and bone biochemical markers were also evaluated. Female and male subjects were analyzed independently, and each gender was divided into 2 groups, based on whether vertebral fractures were present. Results: The prevalence of vertebral fracture was 16.7% (95% CI 13.3-20.1) in women and 21.2% (95% CI 16.6-25.7) in men. Logistic regression analyses using variables that were significant in the univariate analysis, in female group showed that age (OR=1.12, 95% CI 1.06-1.18; p<0.001) and femoral neck T-score (OR=0.61, 95% CI 0.46-0.88; p=0.006) were independently factors in predicting vertebral fracture. In the male group, logistic regression analyzes demonstrated that chronic faller condition (OR=2.54 95% CI 1.1-5.9; p=0.031) and femoral neck T-score (OR=0.72, 95% CI 0.53-0.96; p=0.025) were independent parameters in predicting vertebral fractures. Conclusions: Our results suggest that radiographic vertebral fractures are common in Brazilian community-dwelling elderly and that a low femoral neck T-score was an important risk factor for this condition in both males and females. Age was also significantly correlated with the presence of vertebral fractures in women, and chronic faller was correlated with vertebral fractures in men.

Page generated in 0.0577 seconds