• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 16
  • 16
  • 10
  • 9
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

High Speed (MHz) Switch Mode Power Supplies (SMPS) using Coreless PCB Transformer Technology

Kotte, Hari Babu January 2011 (has links)
The most essential unit required for all the electronic devices is the Power Supply Unit (PSU). The main objective of power supply designers is to reduce the size, cost and weight, and to increase the power density of the converter. There is also a requirement to have a lower loss in the circuit and hence in the improvement of energy efficiency of the converter circuit. Operating the converter circuits at higher switching frequencies reduces the size of the passive components such as transformers, inductors, and capacitors, which results in a compact size, weight, and increased power density of the converter. At present the switching frequency of the converter circuit is limited due to the increased switching losses in the existing semiconductor devices and in the magnetic area, because of increased hysteresis and eddy current loss in the core based transformer. Based on continuous efforts to improve the new semi conductor materials such as GaN/SiC and with recently developed high frequency multi-layered coreless PCB step down power transformers, it is now feasible to design ultra-low profile, high power density isolated DC/DC and AC/DC power converters. This thesis is focussed on the design, analysis and evaluation of the converters operating in the MHz frequency region with the latest semi conductor devices and multi-layered coreless PCB step-down power and signal transformers. An isolated flyback DC-DC converter operated in the MHz frequency with multi-layered coreless PCB step down 2:1 power transformer has been designed and evaluated. Soft switching techniques have been incorporated in order to reduce the switching loss of the circuit. The flyback converter has been successfully tested up to a power level of 10W, in the switching frequency range of 2.7-4 MHz. The energy efficiency of the quasi resonant flyback converter was found to be in the range of 72-84% under zero voltage switching conditions (ZVS). The output voltage of the converter was regulated by implementing the constant off-time frequency modulation technique. Because of the theoretical limitations of the Si material MOSFETs, new materials such as GaN and SiC are being introduced into the market and these are showing promising results in the converter circuits as described in this thesis. Comparative parameters of the semi conductor materials such as the vi energy band gap, field strengths and figure of merit have been discussed. In this case, the comparison of an existing Si MOSFET with that of a GaN MOSFET has been evaluated using a multi-layered coreless PCB step-down power transformer for the given input/output specifications of the flyback converter circuit. It has been determined that the energy efficiency of the 45 to 15V regulated converter using GaN was improved by 8-10% compared to the converter using the Si MOSFET due to the gate drive power consumption, lower conduction losses and improved rise/fall times of the switch. For some of the AC/DC and DC/DC applications such as laptop adapters, set-top-box, and telecom applications, high voltage power MOSFETs used in converter circuits possess higher gate charges as compared to that of the low voltage rating MOSFETs. In addition, by operating them at higher switching frequencies, the gate drive power consumption, which is a function of frequency, increases. The switching speeds are also reduced due to the increased capacitance. In order to minimize this gate drive power consumption and to increase the frequency of the converter, a cascode flyback converter was built up using a multi-layered coreless PCB transformer and this was then evaluated. Both simulation and experimental results have shown that with the assistance of the cascode flyback converter the switching speeds of the converter were increased including the significant improvement in the energy efficiency compared to that of the single switch flyback converter. In order to further maximize the utilization of the transformer, to reduce the voltage stress on MOSFETs and to obtain the maximum power density from the power converter, double ended topologies were chosen. For this purpose, a gate drive circuitry utilising the multi-layered coreless PCB gate drive transformer was designed and evaluated in both a Half-bridge and a Series resonant converter. It was found that the gate drive power consumption using this transformer was less than 0.8W for the frequency range of 1.5-3.5MHz. In addition, by using this gate drive circuitry, the maximum energy efficiency of the series resonant converter was found to be 86.5% with an output power of 36.5W.
12

Multilayered Coreless Printed Circuit Board (PCB) Step-down Transformers for High Frequency Switch Mode Power Supplies (SMPS)

Ambatipudi, Radhika January 2011 (has links)
The Power Supply Unit (PSU) plays a vital role in almost all electronic equipment. The continuous efforts applied to the improvement of semiconductor devices such as MOSFETS, diodes, controllers and MOSFET drivers have led to the increased switching speeds of power supplies. By increasing the switching frequency of the converter, the size of passive elements such as inductors, transformers and capacitors can be reduced. Hence, the high frequency transformer has become the backbone in isolated AC/DC and DC/DC converters. The main features of transformers are to provide isolation for safety purpose, multiple outputs such as in telecom applications, to build step down/step up converters and so on. The core based transformers, when operated at higher frequencies, do have limitations such as core losses which are proportional to the operating frequency. Even though the core materials are available in a few MHz frequency regions, because of the copper losses in the windings of the transformers those which are commercially available were limited from a few hundred kHz to 1MHz. The skin and proximity effects because of induced eddy currents act as major drawbacks while operating these transformers at higher frequencies. Therefore, it is necessary to mitigate these core losses, skin and proximity effects while operating the transformers at very high frequencies. This can be achieved by eliminating the magnetic cores of transformers and by introducing a proper winding structure. A new multi-layered coreless printed circuit board (PCB) step down transformer for power transfer applications has been designed and this maintains the advantages offered by existing core based transformers such as, high voltage gain, high coupling coefficient, sufficient input impedance and high energy efficiency with the assistance of a resonant technique. In addition, different winding structures have been studied and analysed for higher step down ratios in order to reduce copper losses in the windings and to achieve a higher coupling coefficient. The advantage of increasing the layer for the given power transfer application in terms of the coupling coefficient, resistance and energy efficiency has been reported. The maximum energy efficiency of the designed three layered transformers was found to be within the range of 90%-97% for power transfer applications operated in a few MHz frequency regions. The designed multi-layered coreless PCB transformers for given power applications of 8, 15 and 30W show that the volume reduction of approximately 40-90% is possible when compared to its existing core based counterparts. The estimation of EMI emissions from the designed transformers proves that the amount of radiated EMI from a three layered transformer is less than that of the two layered transformer because of the decreased radius for the same amount of inductance. Multi-layered coreless PCB gate drive transformers were designed for signal transfer applications and have successfully driven the double ended topologies such as the half bridge, the two switch flyback converter and resonant converters with low gate drive power consumption of about half a watt. The performance characteristics of these transformers have also been evaluated using the high frequency magnetic material made up of NiZn and operated in the 2-4MHz frequency region. These multi-layered coreless PCB power and signal transformers together with the latest semiconductor switching devices such as SiC and GaN MOSFETs and the SiC schottky diode are an excellent choice for the next generation compact SMPS.
13

Synchronised Pulsewidth Modulation Strategies Based On Space Vector Approach For Induction Motor Drives

Narayanan, G 08 1900 (has links)
In high power induction motor drives, the switching frequency of the inverter is quite low due to the high losses in the power devices. Real-time PWM strategies, which result in reduced harmonic distortion under low switching frequencies and have maximum possible DC bus utilisation, are developed for such drives in the present work. The space vector approach is taken up for the generation of synchronised PWM waveforms with 3-Phase Symmetry, Half Wave Symmetry and Quarter Wave Symmetry, required for high-power drives. Rules for synchronisation and the waveform symmetries are brought out. These rules are applied to the conventional and modified forms of space vector modulation, leading to the synchronised conventional space vector strategy and the Basic Bus Clamping Strategy-I, respectively. Further, four new synchronised, bus-clamping PWM strategies, namely Asymmetric Zero-Changing Strategy, Boundary Sampling Strategy-I, Basic Bus Clamping Strategy-II and Boundary Sampling Strategy-II, are proposed. These strategies exploit the flexibilities offered by the space vector approach like double-switching of a phase within a subcycle, clamping of two phases within a subcycle etc. It is shown that the PWM waveforms generated by these strategies cannot be generated by comparing suitable 3-phase modulating waves with a triangular carrier wave. A modified two-zone approach to overmodulation is proposed. This is applied to the six synchronised PWM strategies, dealt with in the present work, to extend the operation of these strategies upto the six-step mode. Linearity is ensured between the magnitude of the reference and the fundamental voltage generated in the whole range of modulation upto the six-step mode. This is verified experimentally. A suitable combination of these strategies leads to a significant reduction in the harmonic distortion of the drive at medium and high speed ranges over the conventional space vector strategy. This reduction in harmonic distortion is demonstrated, theoretically as well as experimentally, on a constant V/F drive of base frequency 50Hz for three values of maximum switching frequency of the inverter, namely 450Hz, 350Hz and 250Hz. Based on the notion of stator flux ripple, analytical closed-form expressions are derived for the harmonic distortion due to the different PWM strategies. The values of harmonic distortion, computed based on these analytical expressions, compare well with those calculated based on Fourier analysis and those measured experimentally.
14

PV Based Converter with Integrated Battery Charger for DC Micro-Grid Applications

Salve, Rima January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This thesis presents a converter topology for photovoltaic panels. This topology minimizes the number of switching devices used, thereby reducing power losses that arise from high frequency switching operations. The control strategy is implemented using a simple micro-controller that implements the proportional plus integral control. All the control loops are closed feedback loops hence minimizing error instantaneously and adjusting efficiently to system variations. The energy management between three components, namely, the photovoltaic panel, a battery and a DC link for a microgrid, is shown distributed over three modes. These modes are dependent on the irradiance from the sunlight. All three modes are simulated. The maximum power point tracking of the system plays a crucial role in this configuration, as it is one of the main challenges tackled by the control system. Various methods of MPPT are discussed, and the Perturb and Observe method is employed and is described in detail. Experimental results are shown for the maximum power point tracking of this system with a scaled down version of the panel's actual capability.
15

Energy conversion unit with optimized waveform generation

Sajadian, Sally January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The substantial increase demand for electrical energy requires high efficient apparatus dealing with energy conversion. Several technologies have been suggested to implement power supplies with higher efficiency, such as multilevel and interleaved converters. This thesis proposes an energy conversion unit with an optimized number of output voltage levels per number of switches nL=nS. The proposed five-level four-switch per phase converter has nL=nS=5/4 which is by far the best relationship among the converters presented in technical literature. A comprehensive literature review on existing five-level converter topologies is done to compare the proposed topology with conventional multilevel converters. The most important characteristics of the proposed configuration are: (i) reduced number of semiconductor devices, while keeping a high number of levels at the output converter side, (ii) only one DC source without any need to balance capacitor voltages, (iii) high efficiency, (iv) there is no dead-time requirement for the converters operation, (v) leg isolation procedure with lower stress for the DC-link capacitor. Single-phase and three-phase version of the proposed converter is presented in this thesis. Details regarding the operation of the configuration and modulation strategy are presented, as well as the comparison between the proposed converter and the conventional ones. Simulated results are presented to validate the theoretical expectations. In addition a fault tolerant converter based on proposed topology for micro-grid systems is presented. A hybrid pulse-width-modulation for the pre-fault operation and transition from the pre-fault to post-fault operation will be discussed. Selected steady-state and transient results are demonstrated to validate the theoretical modeling.
16

Asynchronní motor s vnějším rotorem / Induction machine with outer rotor

Chvatík, Štěpán January 2018 (has links)
Induction machine; outer rotor; water pump; thermal network; thermal analysis; optimization; electromagnetic model; finite element method; thermal insulation class

Page generated in 0.1027 seconds